Professional Documents
Culture Documents
MANUAL
FUNCTION SETUP:
four digits passwords +# ", original password is 1234. After that please
LED turns on, please face the GSM main unit in a 20 cm distance to leave words. After that,
please press any key-press, you can hear one short and one long sound “B”, that means
leaving words is now successfully completed (Note: Time for Leaving words is 10 seconds).
2. Six group of alarm telephone number stored: Please accordingly on the keyboard input
"#?*+phone number+#", with one sound “B” from each confirmed step,
hereinto, "?" stands for which group. This system now is set for six group of phone
number to dial out, therefore,"?" is (1-6), "#*" is necessarily prescribed format. Here,
supposing the first group phone number is 075512345678, on the keyboard, you should
sixth group of phone number, on the keyboard, you should accordingly input
completed, you can hear one short and one long prompt sound. If failure, than you will
constantly hear “B” sound or input format incorrectly
3. Phonic alarm system setup: Please on the keyboard accordingly input "#9*1#",
one short and one long prompt sound can be heard. That means successfully completed
(after setup, the system will hoot once alarm)
4. Mute alarm: Please on the keyboard accordingly input "#9*0#", one short and
one long prompt sound can be heard. That means successfully completed. The siren won't
be hooted once alarm.
5. Enlarge operating prompt sound by turned on Siren sound by remote controller: Please
on the keyboard accordingly input "#9*3#", than when you operate it by remote
controller, siren can be heard while each operation. (Each operation by remote control to
turn on siren that just enlarges the operating sound)
6. Shut off siren prompt sound by remote controller: Please on the keyboard accordingly
input "#9*2#", you can hear one sound “B” to prompt this order.
7. Set up siren hooting time: Please on the keyboard accordingly input "#9*4?#",
hereinto, "?" stands for the siren hooting minute. If preset "#9*45#", the siren
will hoot for five minutes once alarm; If you want to keep the siren hooting, please input
9. Main unit network function and ID code preset: This GSM main unit can work with alarm
receiving central monitoring system. It is requested to input the distributed ID codes to
11. Delete telephone number: If you want to delete the first group, please input"#1
*# "; the second, input "#2*# ". The rest may be deduced by analogy
12. System reset order: "#9*69+ Four digits passwords +#", After inputting
this order, this system is cleared and recovered as original default: Siren sound accompany,
phonic alarm, siren hooting time for one minute, None of telephone number or recorded
voice message. All make no difference with system password and RF codes.
Note: press one keyboard with one sound “B”, all successful operation with two sound “B”, if
operation error, it prompts sound “B” continuously.
ACTIVATED/DEACTIVATED
When you lock the gate or door, please press "". Armed LED turns on with one sound “B”,
that means this alarm panel now is activated. Meanwhile, it will give an alarm if any illegal
intruders will be detected by sensor. User can follow this function to activate or deactivate this
GSM alarm panel thru telephone.
Please press " " button when coming back home. Armed LED turns off with one sound “B”,
that means the alarm panel now is deactivated. So, open the door to come in. Only if power is
not shut off, the gas leakage detector and smoke and fire detector are always activated without
any effectiveness thru remote controller.
EMERGENCY FUNCTION
Supposing accident happened, please press " " quickly, than this system will be right now in
the emergency position and auto dial out alarm phone number.
You want to rest at night without any disturb of wrong report when the alarm host is in the
state of on-duty. In order to avoid this point you can do as bellows: Firstly press" “ on the
remote controller twice continuously. The infrared detector will be in the state of disarm after
you hear a long beep. Press “" to realize arm again.
than: Press "#" keyboard of telephone to hang up the phone as well as stop dialling out alarm
phone number and stop siren. This system will always dial the preset telephone until
deactivating the system or press "#" to confirm it. Press "1" is for locale monitor for 20
seconds, if you want to continue to monitor it, you must press "1" again in 20 seconds. "2"
to turn on siren, "3" to shut off siren, "4" to activate the GSM alarm panel, "5" to
deactivate the GSM alarm panel, "* " to hear recorded voice message.
If you are out of city and forgot to activate this system or want to perform other long-distance
remote control, please carry out the following ways:
Please dial this GSM phone number, after three rings, it automatically connects with your
phone as well as you hear two sounds “B” to prompt connecting. Meanwhile, please input four
passwords to activate the long-distance remote control, if passwords correct, you can hear two
sounds "BB" to prompt the correct passwords, if passwords error, you can hear continues
sounds “B” to prompt wrong passwords, three times to try, than shut off the phone. After
password is correct to start to have long-distance remote control, for example: "1" is for
locale monitor, "2" to turn on siren, "3" to shut off siren, "4" to activate the system, "5"
Please by remote controller press "# 0 * +mobile phone number + # " and
phone number. Please press "#0*# ".The above operation, you can hear two sounds
"1234", when you like to do remote control function, please edit by mobile phone
"1234DISARM", After this system receive this short message, it is auto disarm the system and
reply to your like this message "Host is deactivated!". Supported short message order as
follows;
Password+ARM (i.e: 1234ARM) Reply message: Host is activated!
Password+DISARM (i.e.- 1234DISARM) Reply message: Host is deactivated!
Password +ONSIREN (i.e: 1234 0NSIREN) Reply message: The siren is opened!
Password+OFFSIREN (i.e: 1234 0FFSIREN) Reply message: The siren is closed!
Password+CHECK (ie.1234CHECK) Reply message: Host is activated! OR: Host is
deactivated! (Depend on the current position)
COMMAND CHECK
#0* receiving alarm short message number # (set receiving alarm short message
number)
#9*80 password # record and leaving words (alarm record leaving word)
#9*90 password # remote transmit (wireless reviewed code to set up new code)
If the password is correct but input order is wrong, it shows “The command is wrong”
NOTE: input letter must be capitalization letter without any space along character. For
example, "1234ArM" is wrong character.
AC Prompt function
If this system with internal batteries, when external electricity power supply is shut off, it
automatically sends out short message to notify the master.
Once AC shut off, it sends out the short message as follows: AC power shut off
Once external electricity power supply is shut off, it sends out the short message as below: AC
power recovered.
Warning: any possible explode by improper operation of Li-ion batteries; please make use of
the safe battery with circuit protected and quality improved. Please take out of the batteries if
the batteries are deactivated for a long period.
How to preset the accessories to work with main alarm unit
SPECIFICATION
TROUBLE SHOOTING
1. Failure to dial the telephone, please check off SIMCARD and network with telephone number
is correct absolutely.
2. Passwords input problem by long-distance operation: please review if your passwords are
correct or reset.