You are on page 1of 68

ROHDE & SCHWARZ

ROMES
Basic Operation
Training

Introduction

Measurement Work Flow


1. Connect Devices
2 .Start ROMES
3. Load workspace file (*.rsxks) (Step 3.5)

(Follow step 3.1 3.4 if workspace has not been created)

Step 4: Start measurement

Step 5: Drive Test

Step 6: Stop measurement


Step 7: Exit ROMES &
Open Measurement File

Romes Basic Operation Training


15TMO-Q273_Aug13

Step 1: Connect Device

Making Connection
Dongle

Antenna

TSMW
LAN Cable
Power

Romes Basic Operation Training


15TMO-Q273_Aug13

GPS
Antenna

Configure IP Address (Laptop)

Romes Basic Operation Training


15TMO-Q273_Aug13

Configure IP Address (Laptop)

l The IP address of the TSMW is by default set to 192.168.0.2


Romes Basic Operation Training
15TMO-Q273_Aug13

Firmware/Options Installation

Remember to turn-off firewall


Only need to do this step if new firmware is released
Romes Basic Operation Training
15TMO-Q273_Aug13

Step 2: Start Romes

Start ROMES

With Dongle (for measurement)

Without Dongle (for replay, export, post process)


Romes Basic Operation Training
15TMO-Q273_Aug13

Step 3: Create/Load WorkSpace

Creating Workspace
l A workspace contains all measurement settings
l It only needs to be created once and can be recalled on following

measurements

Step 3.1: Load SW Drivers


Step 3.2: Configure SW Driver

Create
workspace

Step 3.3: Load Map


Step 3.4: Save Workspace

Romes Basic Operation Training


15TMO-Q273_Aug13

Step3.1: Load SW Drivers

Software Drivers(Loading)
l

Add/Remove Hardware
Loading of respective technologies drivers.

Available Drivers
Dependent on options purchased by Customer.

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Loading)
l

Resource Allocation
Allocate resources on various Front End.
Wrong Allocation prevent user from connection.
Clicking on Distribution allows auto allocation by system.

Romes Basic Operation Training


15TMO-Q273_Aug13

Step 3.2: Configure Loaded Drivers

Software Drivers(Loading)
l

Loaded Drivers
Right Window shows successful loaded drivers.

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

Configuration of loaded Drivers


Configure respective loaded drivers.

Sub Title2
Content

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

CDMA Driver
Name of carriers
Frequency/channel/band etc to decode

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

CDMA Driver
Saving/Loading of configured driver as Template.

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

UMTS PN Driver
Name of carriers
Frequency/channel/band etc to decode

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

UMTS PN Driver
Saving/Loading of configured driver as Template.

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

Wimax Driver
Name of carriers
Frequency/Bandwidth etc to decode

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

Wimax Driver
Saving/Loading of configured driver as Template.

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

GSM Driver
Specify the GSM network, channels etc to decode.
Saving/Loading of Template.

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

BTSPE Driver
Enable required technologies for BTSPE.
Dependent on options purchased by customer.
(Note: Wimax BTSPE is not supported)

Optimization at click of button.

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

BTSPE Driver
l Min. position error (estimation cutoff)
Defines a distance in meter which limits the position
estimation to a reasonable accuracy for performance reasons.
If 66% probability of the estimated position falls below this
distance, the estimation process for this transmitter is finished.

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

BTSPE Driver
l Update rate of results
Defines the period in seconds between estimation orders for
the position estimator. After executing the estimation order,
new position estimation results will be requested from the
position estimator and will be stored in the measurement file
(*.rscmd).

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

BTSPE Driver
l

Tower Merger Mode


Assume several transmitters are located on the same tower
(geographic position).
The estimation algorithm can improve estimation accuracy
significantly.

The tower merging supports the following


modes:
OFF: which prevents merging the position of towers
Aggressive: which may improve the amount of
merged signals on the cost of a higher probability of
wrong assumptions
Moderate: which ensures that no signals are merged
by mistake at the cost of less merged signals.

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

BTSPE Driver
l

Position estimation knowledge base file


Use/dont use a knowledge base file to enhance later measurements.
Discard all measurements older than xxx hours when storing the
knowledge base
For performance reasons and data volume limiting: The option to
discard older measurements (than <xxx> hours) from the knowledge
base when storing the file.

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

RF PowerScan Driver

Creation of multiple windows for RF powerscan.

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

RF PowerScan Driver
l

Basic Settings
Specify Sweep Name, Frequency etc.

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

RF PowerScan Driver
l

Measurement Settings
Specify Bandwidth/FTT etc.

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

RF PowerScan Driver
l

Detector Settings
Specify Count of Lines/RMS/Max etc.

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

RF PowerScan Driver
l

Channel Filter
Enable filtering on specify signal in RF power scan

Romes Basic Operation Training


15TMO-Q273_Aug13

Software Drivers(Configuration)
l

RF PowerScan Driver
l

Example setting.

Romes Basic Operation Training


15TMO-Q273_Aug13

Step 3.3: Load Map

Load MapInfor Map


l

MapInfor Map
Right Click on the Navigation View
Click on Map -> Load MapInfo Map -> Load Map
User need to provide own license map

Romes Basic Operation Training


15TMO-Q273_Aug13

Load OpenStreet Map


l

Open StreetMap

Right Click on the Navigation View.


Click on Map -> Load OpenStreetMap.
Required Internet Connection.
Required licensed dongle and GPS signal if loading map during
outdoor measurement.

Romes Basic Operation Training


15TMO-Q273_Aug13

Loading Parameters on Map


l

Configure Map

Right Click on the Navigation View> Configure


Choose the parameter of interest to be displayed on the map.
During Measurement no additional parameters can be defined.
New parameters can be display on map in replay file.

Romes Basic Operation Training


15TMO-Q273_Aug13

Step 3.4 Save Workspace

Saved WorkSpace
l

Workspace

Saving of work space after all configuration is done.

Romes Basic Operation Training


15TMO-Q273_Aug13

Step 3.5 Load Workspace

Load Workspace
l

Workspace

Open work space from previous setting.

Romes Basic Operation Training


15TMO-Q273_Aug13

Step 4: Start Measurement

Start Measurement

Romes Basic Operation Training


15TMO-Q273_Aug13

Step 5: Start Drive Test

Start Drive Test

Romes Basic Operation Training


15TMO-Q273_Aug13

Step 6: Stop Measurement

Stop Measurement

Romes Basic Operation Training


15TMO-Q273_Aug13

Step 7: Open Measurement File

Replay Measurement File

Romes Basic Operation Training


15TMO-Q273_Aug13

Replay Measurement File

Romes Basic Operation Training


15TMO-Q273_Aug13

8.0: Others Information

8.1: Indoor Measurement

Load Indoor Map


l

Navigation View

Maps

Romes Basic Operation Training


15TMO-Q273_Aug13

Load Indoor Map


l

Navigation View

Maps

Romes Basic Operation Training


15TMO-Q273_Aug13

Load Indoor Map


l

Navigation View

Maps

Reference: http://wise.cnit.it/files/user79/indoor-map.png

Romes Basic Operation Training


15TMO-Q273_Aug13

Configure Software Driver


l

Indoor Driver
Repeat Step 2 by loading respective technologies driver. For navigation driver,
change to indoor input.

Hot Spot
Continuous

Romes Basic Operation Training


15TMO-Q273_Aug13

Configure Software Driver


l

Indoor Driver

Hot Spot

Romes Basic Operation Training


15TMO-Q273_Aug13

Configure Software Driver


l

Indoor Driver

Continuous

Romes Basic Operation Training


15TMO-Q273_Aug13

Configure Software Driver


l

Route Track View


Enable/Disable Previous
Route information in new measurement.

Romes Basic Operation Training


15TMO-Q273_Aug13

8.2: Network Provider Database

Network Provider Database


l

Updating of Network Provider Database

Tools> Network Provider Database

Operator Name

Operator Country

Romes Basic Operation Training


15TMO-Q273_Aug13

Operator
Logo

Network Provider Database


l

Updating of Network Provider Database

Updating/Adding of operators information/ icon/ Band etc.


Browse to country of interest to
update operator information.

To
provide
the
operators logo. The
logo need to be in
.ico format.

Operator Name

Operator Country

Operator
Logo

To
define
the
Operators and its
supported
technology, band and
channels

Romes Basic Operation Training


15TMO-Q273_Aug13

Note
l

These training slides provide basic ROMES operation instruction for


recording. For more detail setting, please refer to ROMES Manual.

Romes Basic Operation Training


15TMO-Q273_Aug13

Title
l

Sub Title1
Content

Sub Title2
Content

Romes Basic Operation Training


15TMO-Q273_Aug13

THE END