50ZP
Single-Package Electric
Cooling Units
2 to 5 Nominal Tons

Single Package Air-Conditioning


Units with:
easy installation design
corrosion-proof basepan
pre-painted steel cabinet
sloped drain pan for improved
indoor air quality
top cover service access
lightweight, compact construction

Features/Benefits
Compact, horizontal supply
and return unit, combining easy installation and
maintenance with efficient
performance.
Easy to install
The 50ZP units are small, compact, and
easy to handle. Every 50ZP unit has
an identical 32 x 51-in. footprint to
make jobsite planning simple. The concise design uses less sheet metal and
makes the 50ZP units lighter than other
units. The unit can be easily positioned
on the jobsite with the hand holds built
into the unit basepan. Drop-in cartridge style heaters are utilized to minimize installation time. The 50ZP unit
was designed with potential safety hazards in mind. There are no sharp edges
or corners which could injure a worker.

Top cover service access


The 50ZP units are designed to be serviced from the top. The split-top design allows easy access for installation
and maintenance procedures on the
unit. Routine maintenance tasks such as
coil cleaning are sped up with
through-the-top access. Multiple side
panels do not need to be removed as
with other units.

Copyright 1997 Carrier Corporation

Form 50ZP-1PD

No-rust basepan with


integrated drain pan

Lightweight, compact
construction

The 50ZP units feature a tough, hightech, composite material basepan with
integrated drain pan. The composite
material eliminates the potential problems of rust and premature replacement
which are common with standard metal
basepans.
Each 50ZP basepan is sloped to
eliminate standing water per ASHRAE
Standard 62-89.

The 50ZP unit is the lightest, most compact packaged unit that Carrier has
ever designed. Its light weight (222 lbs
for the 50ZP024 unit) makes the unit
easier to handle. The low height (22-in.
for 50ZP024-036, 30-in. for 50ZP042,
048, and 34-in. for 50ZP060 units)
keeps ductwork to a minimum and
makes the unit less visible.

Durable pre-painted steel


cabinet
The watertight construction and
corrosion-resistant finish of the 50ZP
unit will keep it looking like new for
years. Carriers paint treatment process
ensures quality protection against the
elements. A compact, low-profile design
utilizes a louvered coil enclosure for
protection against vandalism and hail
damage.

Indoor-air quality
A sloped drain pan minimizes the
amount of standing water inside the
unit, which limits algae growth. The
drain pan is made of a rust-proof material and will not deteriorate or release
foreign matter into the conditioned air.

Efficient, dependable
performance
The 50ZP units offer 10.0 SEER (Seasonal Energy Efficiency Rate) cooling
performance efficiencies. This high performance level can reduce cooling expenses by as much as 25% compared to
older cooling equipment (depending on
local climate conditions). A highefficiency, multi-speed blower motor
system ensures quality performance with
most duct systems. The computerdesigned blower wheel is balanced for
quiet operation.

Rugged, reliable
construction
The 50ZP units utilize a structural beam
design to form the four sides of the
cabinet. Only 12 different pieces of sheet

Model number nomenclature

Table of contents
Page
Features/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,2
Model Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ARI Capacity Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4,5
Base Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-14
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Typical Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17,18
Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19,20

metal are used in the unit construction


to simplify the unit for greater reliability.
The 50ZP units are built to last.

Durable, dependable
components
Compressors are designed for high
efficiency. Each compressor is hermetically sealed against contamination to
help promote longer life and dependable
operation. Vibration isolation provides
quiet operation. Reciprocating compressors have internal high-pressure and
overcurrent protection.
Direct-drive multispeed, PSC (permanent split capacitor) blower
motor is standard on all models.
Direct-drive, PSC condenser-fan
motors are designed to help reduce
energy consumption and provide for
cooling operation down to 40 F.
Refrigerant system is designed to
provide dependability. Liquid refrigerant
strainers are used to promote clean,
unrestricted operation. Each unit leaves
the factory with a full refrigerant charge.
Refrigerant service connections make
checking operating pressures easier.

ARI* capacity ratings


UNIT 50ZP
024
030
036
042
048
060

NET COOLING CAPACITY


(Btuh)
22,800
30,000
34,200
40,000
46,000
57,000

STANDARD CFM

SEER**

800
1000
1200
1400
1600
2000

10.0
10.0
10.0
10.0
10.0
10.0

SOUND RATING
(dB)
80
84
84
84
84
84

LEGEND
db
Dry Bulb
dB
decibels (10 decibels = 1 bel)
SEER Seasonal Energy Efficiency Ratio
wb
Wet Bulb
*Air Conditioning and Refrigeration Institute.
Rated in accordance with U.S. Government DOE (Department of Energy) test
procedures and/or ARI Standard 210/240-89.
**All units have factory-installed time-delay relay.
Rated in accordance with ARI Standard 270-84.
NOTES:
1. Ratings are net values, reflecting the effects of circulating fan heat.
2. Cooling Capacity Ratings are based on cooling standard:
80 F db/67 F wb indoor air entering temperature
95 F db air entering outdoor unit

Physical data
UNIT 50ZP
OPERATING WEIGHT (lb)
COMPRESSOR TYPE
REFRIGERANT
Charge (lb)
REFRIGERANT METERING DEVICE
CONDENSER
Rows...Fins/in.
Total Face Area (sq ft)
CONDENSER FAN
CFM
Nominal Rpm
Motor Hp
Diameter (in.)
EVAPORATOR COIL
Rows...Fins/in.
Total Face Area (sq ft)
EVAPORATOR FAN MOTOR
Blower Motor Size (in.)
Nominal Cfm
Rpm Range
Number of Speeds
Factory Speed Setting
Motor Hp
CONNECTING DUCT SIZES
Supply Air (in.)
Return Air (in.)
FIELD-SUPPLIED RETURN AIR FILTER
Throwaway (in.)

024
222

3.0

1...17
7.9
1600
825
1 8
20
2...15
3.1
10 x 8
800
550-1000
3
Low
1 4

24 x 24

030
236

036
042
048
250
297
310
Reciprocating
R-22
3.9
4.7
4.4
6.1
Acutrol System
Copper Tubes, Aluminum Plate Fins
1...17
2...17
1...17
2...17
7.9
6.2
11.1
8.6
Propeller
2000
2000
2600
2600
1100
1100
1100
1100
1 4
1 4
1 4
1 4
20
20
20
20
Copper Tubes, Aluminum Plate Fins
3...15
3...15
3...15
3...15
2.8
3.1
3.9
4.3
Direct Drive
10 x 8
10 x 8
10 x 9
10 x 9
1000
1200
1400
1600
550-1000
800-1050
800-1050
1000-1100
3
3
3
2
Med
Low
Med
Low
1 4
1 2
1 2
3 4
Round
14
14
24 x 24

24 x 24

24 x 24

24 x 30

060
350

7.5

2...17
10.7
2800
1100
1 4
20
4...15
4.9
10 x 10
2000
950-1100
3*
Low
1
Square
13.9 x 13.9
13.9 x 27.8
24 x 30

*460-v motors are 2-speed only.


Required filter sizes shown are based on the ARI (Air Conditioning and Refrigeration Institute) rated
airflow at a velocity of 300 ft/min for throwaway type or 450 ft/min for high capacity type. Recommended filters are 1-in. thick.

Accessories
ACCESSORY
Outdoor Thermostat
Crankcase Heater (230-1-60)
Thermostat and Subbase
Electronic Programmable Thermostat
Controls Upgrade Kit
Time GuardT II Kit
Low-Ambient Kit
Electric Heat with Single-Point Kit (5.0 to 20.0 kW)

Electronic programmable thermostat provides 2-stage


heating and 2-stage cooling control with remote communication ability.
Thermostat and subbase provide heating and cooling
unit control. The subbase provides system and fan switching at the thermostat location.
Low-ambient kit (Motormastert II device) allows the
use of mechanical cooling down to outdoor ambient temperatures as low as 0 F.

Solid-state Time Guard II device protects compressor


by preventing short cycling.
Crankcase heater warms crankcase oil to reduce refrigerant migration and ensure proper compressor lubrication.
(Recommended on 208/230-v single-phase units in sizes
024-042 only.)
Electric heaters provide heat in the unit when required.
Each package has a heater module that slides into keyed
mounting slots in the fan inlet. Heater sizes range from 5.0
to 20.0 kW. The electric heater design allows the use of a
single-point power supply for the entire unit, resulting in
lower installed costs.
Controls upgrade kit includes high- and low-pressure
switches which provide additional safety features and protect the unit from running at unsuitable pressures.
Outdoor thermostat brings second stage of 2-stage electric heater on line when the outdoor-air temperature falls
below the set point.

ELECTRIC HEATERS
ODS CATALOG
ORDERING NO.
CPHEATER026A00
CPHEATER039A00
CPHEATER025A00
CPHEATER027A00
CPHEATER029A00
CPHEATER030A00
CPHEATER031A00
CPHEATER033A00
CPHEATER034A00
CPHEATER035A00
CPHEATER036A00
CPHEATER037A00

USED WITH SIZES


024
030
036
042
ELECTRIC HEATERS (208/230 SINGLE PHASE 60 Hz)
5.0
X
X
X
X
10.0
X
X
X
X
15.0
X
X
X
20.0
X
X
ELECTRIC HEATERS (208/230 V 3 PHASE 60 Hz)
5.0
X
X
10.0
X
X
15.0
X
X
20.0
X
X
ELECTRIC HEATERS (460 V 3 PHASE 60 Hz)
5.0
10.0
15.0
20.0

NOMINAL
CAPACITY (kW)

LEGEND
ODS Order Distribution System
NOTE: Electric heaters are rated at 240 v and 480 v. Refer to Multiplication Factors table on page 5 for other voltages.

048

060

X
X

X
X
X
X

X
X
X
X
X
X
X
X

THERMOSTATS AND SUBBASES


ODS CATALOG
ORDERING NO.
TSTATCCN2S01-A
TSTATCCP2S01-A
33CSPTN-01
--HH01AD-45

DESCRIPTION
Automatic Changeover 3 Heat/2 Cool (Programmable Residential Thermostat)
Automatic Changeover 3 Heat/2 Cool (Non-Programmable Residential Thermostat)
Automatic Changeover 2 Heat/2 Cool (Programmable Commercial Thermostat)
Manual Changeover 2 Heat/1 Cool (Non-Programmable Thermostat)

LEGEND
ODS Order Distribution System

MULTIPLICATION FACTORS
HEATER kW
RATING
240

480

VOLTAGE
DISTRIBUTION
V/3/60
200
208
230
240
440
460
480

MULTIPLICATION
FACTOR
.69
.75
.92
1.00
.84
.92
1.00

Example: 15.0 kW (at 240 v) heater on 208 v


= 15.0 (.75 mult factor)
= 11.25 capacity at 208 v

Base unit dimensions 50ZP024-036


REQUIRED CLEARANCES TO COMBUSTIBLE MATL
Top of Unit . . . . . . . . . . . . . .
Duct Side of Unit . . . . . . . . . .
Side Opposite Ducts . . . . . . . .
Bottom of Unit . . . . . . . . . . . .
NEC REQUIRED CLEARANCES

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

Millimeters (in.)
. . . .0
. . . .0
. . . .0
. . . .0

Millimeters (in.)
Between Units, Power Entry Side . . . . . . . . . . . . . . . . . 1066.8 (42.00)
Unit and Ungrounded Surfaces, Power Entry Side . . . . . . . 914.0 (36.00)
Unit and Block or Concrete Walls and Other Grounded
Surfaces, Power Entry Side . . . . . . . . . . . . . . . . . . . . 1066.8 (42.00)
REQUIRED CLEARANCES FOR SERVICING
Millimeters (in.)
Condenser Coil Access Side . . . . . . . . . . . . . . . . . . . . . 762.0 (30.00)
Power Entry Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . 762.0 (30.00)
(Except for NEC Requirements)
Unit Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 914.0 (36.00)
Side Opposite Ducts . . . . . . . . . . . . . . . . . . . . . . . . . . 762.0 (30.00)
LEGEND
CG Center of Gravity
NEC National Electrical Code
NOTES:
1. Clearances must be maintained to prevent recirculation of air from outdoorfan discharge, with the exception of the condenser coil (914 mm [36 in.]). A
removable fence or barricade requires no clearance.
2. Dimensions are in millimeters. Dimensions in ( ) are in inches.

UNIT

ELECTRICAL
CHARACTERISTICS

50ZP024
50ZP030
50ZP036

208/230-1-60
208/230-1-60
208/230-1-60, 208/230-3-60

UNIT WT
Lb
222
236
250

Kg
101
107
114

CENTER
X
355.6 (14.00)
355.6 (14.00)
355.6 (14.00)

OF GRAVITY mm (in.)
Y
Z
508.0 (20.00)
241.3 (9.50)
508.0 (20.00)
241.3 (9.50)
508.0 (20.00)
241.3 (9.50)

Base unit dimensions 50ZP042,048


REQUIRED CLEARANCES TO COMBUSTIBLE MATL
Top of Unit . . . . . . . . . . . . . .
Duct Side of Unit . . . . . . . . . .
Side Opposite Ducts . . . . . . . .
Bottom of Unit . . . . . . . . . . . .
NEC REQUIRED CLEARANCES

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

Millimeters (in.)
. . . .0
. . . .0
. . . .0
. . . .0

Millimeters (in.)
Between Units, Power Entry Side . . . . . . . . . . . . . . . . . 1066.8 (42.00)
Unit and Ungrounded Surfaces, Power Entry Side . . . . . . . 914.0 (36.00)
Unit and Block or Concrete Walls and Other Grounded
Surfaces, Power Entry Side . . . . . . . . . . . . . . . . . . . . 1066.8 (42.00)
REQUIRED CLEARANCES FOR SERVICING
Millimeters (in.)
Condenser Coil Access Side . . . . . . . . . . . . . . . . . . . . . 762.0 (30.00)
Power Entry Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . 762.0 (30.00)
(Except for NEC Requirements)
Unit Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 914.0 (36.00)
Side Opposite Ducts . . . . . . . . . . . . . . . . . . . . . . . . . . 762.0 (30.00)
LEGEND
CG Center of Gravity
NEC National Electrical Code
NOTES:
1. Clearances must be maintained to prevent recirculation of air from outdoorfan discharge, with the exception of the condenser coil (914 mm [36 in.]). A
removable fence or barricade requires no clearance.
2. Dimensions are in millimeters. Dimensions in ( ) are in inches.

UNIT

ELECTRICAL
CHARACTERISTICS

50ZP042
50ZP048

208/230-1-60, 208/230-3-60
208/230-1-60, 208/230-3-60

UNIT WT
Lb
297
310

Kg
135
141

X
355.6 (14.00)
355.6 (14.00)

CENTER OF GRAVITY mm (in.)


Y
Z
508.0 (20.00)
304.8. (12.00)
508.0 (20.00)
304.8 (12.00)

Base unit dimensions 50ZP060


REQUIRED CLEARANCES TO COMBUSTIBLE MATL
Top of Unit . . . . . . . . . . . . . .
Duct Side of Unit . . . . . . . . . .
Side Opposite Ducts . . . . . . . .
Bottom of Unit . . . . . . . . . . . .
NEC REQUIRED CLEARANCES

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

Millimeters (in.)
. . . .0
. . . .0
. . . .0
. . . .0

Millimeters (in.)
Between Units, Power Entry Side . . . . . . . . . . . . . . . . . 1066.8 (42.00)
Unit and Ungrounded Surfaces, Power Entry Side . . . . . . . 914.0 (36.00)
Unit and Block or Concrete Walls and Other Grounded
Surfaces, Power Entry Side . . . . . . . . . . . . . . . . . . . . 1066.8 (42.00)
REQUIRED CLEARANCES FOR SERVICING
Millimeters (in.)
Condenser Coil Access Side . . . . . . . . . . . . . . . . . . . . . 762.0 (30.00)
Power Entry Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . 762.0 (30.00)
(Except for NEC Requirements)
Unit Top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 914.0 (36.00)
Side Opposite Ducts . . . . . . . . . . . . . . . . . . . . . . . . . . 762.0 (30.00)
LEGEND
CG Center of Gravity
NEC National Electrical Code
NOTES:
1. Clearances must be maintained to prevent recirculation of air from outdoorfan discharge, with the exception of the condenser coil (914 mm [36 in.]). A
removable fence or barricade requires no clearance.
2. Dimensions are in millimeters. Dimensions in ( ) are in inches.

UNIT

ELECTRICAL
CHARACTERISTICS

50ZP060

230-1-60, 208/230-3-60, 460-3-60

UNIT WT
Lb
350

Kg
159

X
355.6 (14.00)

CENTER OF GRAVITY mm (in.)


Y
Z
508.0 (20.00)
355.6 (14.00)

Selection procedure
I Determine cooling and heating requirements at
design conditions.
Given:
Required Cooling Capacity (TC) . . . . . . 34,000 Btuh
Sensible Heat Capacity (SHC) . . . . . . . 25,000 Btuh
Required Heating Capacity . . . . . . . . . . 15,000 Btuh
Outdoor Entering-Air Temperature . . . . . . . . . . . 95 F
Indoor Entering-Air
Temperature . . . . . . . . . . . . . . 80 F edb; 67 F ewb
Indoor-Air Quantity . . . . . . . . . . . . . . . . . . . 1200 cfm
External Static Pressure . . . . . . . . . . . . . . 0.20 in. wg
Electrical Characteristics (V-Ph-Hz) . . . . . . . 230-1-60
II Select unit based on required cooling capacity.
Enter Cooling Capacities table at condenser entering
temperature of 95 F, indoor air entering at 1200 cfm
and 67 F ewb. The 50ZP036 unit provides a total cooling capacity of 34,200 Btuh and a sensible heat capacity of 25,300 Btuh.
For indoor-air temperature other than 80 F edb, calculate sensible heat capacity correction, as required,
using the formula found in Note 4 following the Cooling Capacities tables.
NOTE: Unit ratings are net capacities.
III Select electric heat.
The required heating capacity is 15,000 Btuh (given).
Determine the electric heat capacity in kW.
15,000 Btuh
= 4.4 kW of heat required
3414 Btuh/kW

Enter the Electric Heaters table on page 4 for 208/


240, single-phase, 50ZP036 unit. The 5-kW heater at
240 v most closely satisfies the heating required. To
calculate kW at 230 v, multiply the heater kW by multiplication factor 0.92 found in the Multiplication
Factors table on page 5.
5 kW x 0.92 = 4.6 kW
4.6 kW x 3414 Btuh/kW = 15,704 Btuh
IV Determine fan speed and power requirements
at design conditions.
Before entering the air delivery tables, calculate the
total static pressure required. From the given, Filter Pressure Drop table, the Accessory Electric Heat Pressure
Drop table, and the Wet Coil Pressure Drop table, find:
External static pressure
0.20 in. wg
Filter
0.10 in. wg
Electric Heat
0.13 in. wg
Wet Coil
0.09 in. wg
Total static pressure

0.52 in. wg

Enter the table for Dry Coil Air Delivery Horizontal


Discharge. At 0.5 in. wg external static pressure and
high speed, the motor delivers 1297 cfm. Interpolating for 0.52 in. wg delivers 1276 cfm, which satisfies
the job requirements.

Performance data
COOLING CAPACITIES
50ZP024
TEMP (F)
AIR ENT
COND
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

85
95
105
115

62
21.4
17.9
2.12
20.5
17.8
2.25
19.3
17.4
2.36
18.0
16.9
2.47

EVAP AIR CFM/BF


800/0.14
Evap Air Ewb (F)
72
67
62
23.2
22.5
21.3
10.5
14.4
18.3
2.18
2.17
2.15
24.5
22.8
20.8
11.5
15.4
18.7
2.39
2.35
2.29
24.3
21.9
19.7
11.8
15.4
18.4
2.56
2.48
2.41
23.2
20.6
18.3
11.7
15.1
17.9
2.70
2.61
2.52

62
28.5
25.8
3.04
26.8
25.0
3.20
25.1
24.1
3.35
26.3
19.6
3.64

EVAP AIR CFM/BF


1000/0.08
Evap Air Ewb (F)
72
67
62
32.1
30.6
29.1
22.9
25.2
27.6
3.21
3.17
3.12
32.6
30.0
27.5
21.0
23.7
26.4
3.31
3.30
3.28
33.1
29.5
25.8
19.1
22.2
25.3
3.41
3.43
3.45
29.8
28.2
26.7
16.0
18.5
21.0
3.85
3.78
3.71

700/0.12
72
23.9
10.9
2.17
24.6
11.4
2.36
24.1
11.5
2.52
22.9
11.2
2.66

67
23.0
14.5
2.15
22.6
14.8
2.31
21.6
14.7
2.44
20.3
14.3
2.56

900/0.15
72
22.3
10.1
2.18
23.5
11.1
2.39
24.1
11.9
2.59
23.3
12.0
2.74

67
21.6
13.9
2.18
22.6
15.6
2.37
22.1
16.0
2.53
20.7
15.8
2.65

62
21.0
18.2
2.17
20.9
19.2
2.33
19.9
19.2
2.46
18.7
18.7
2.58

50ZP030
TEMP (F)
AIR ENT
COND

85
95
105
115

BF
Ewb
kW
SHC
TC

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

875/0.07
72
31.6
21.6
3.14
32.1
19.9
3.24
32.6
18.2
3.34
29.3
15.2
3.77

67
30.0
23.7
3.09
29.5
22.4
3.22
28.9
21.1
3.34
27.8
17.4
3.71

LEGEND
Bypass Factor
Entering Wet Bulb
Total Unit Power Input
Sensible Heat Capacity, 1000 Btuh
Total Cooling Capacity, 1000 Btuh (net)

NOTES:
1. Ratings are net; they account for the effects of the indoor-fan motor
power and heat.
2. Direct interpolation is permissible. Do not extrapolate.
3. The following formulas may be used:
sensible capacity (Btuh)
tldb = t edb
1.10 x cfm

10

1125/0.09
72
32.6
24.2
3.28
33.1
22.1
3.38
33.5
20.0
3.47
30.1
16.7
3.91

67
31.1
26.6
3.23
30.6
24.9
3.37
30.0
23.2
3.50
28.5
19.5
3.85

62
29.6
29.1
3.19
28.1
27.7
3.36
26.6
26.4
3.53
27.0
22.3
3.78

tlwb = Wet-bulb temperature corresponding to enthalpy of air


leaving indoor coil (h lwb)
hlwb = h ewb total capacity (Btuh)
4.5 x cfm
Where: hewb = Enthalpy of air entering indoor coil
4. The SHC is based on 80 F edb temperature of air entering indoor
coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 BF) x (edb 80).

COOLING CAPACITIES (cont)


50ZP036
TEMP (F)
AIR ENT
COND
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

85
95
105
115

62
32.3
29.6
3.42
30.5
28.7
3.59
28.6
27.7
3.75
26.8
26.7
3.91

EVAP AIR CFM/BF


1200/0.10
Evap Air Ewb (F)
72
67
62
39.6
36.2
33.0
19.7
26.0
31.5
3.74
3.61
3.51
37.5
34.2
31.1
19.1
25.3
30.5
3.92
3.79
3.67
35.5
32.1
29.3
18.6
24.5
29.3
4.11
3.96
3.84
33.0
30.1
27.7
17.7
23.8
27.7
4.27
4.14
4.03

62
36.3
31.8
3.81
34.7
31.5
4.03
32.8
30.8
4.25
30.5
29.8
4.45

EVAP AIR CFM/BF


1400/0.12
Evap Air Ewb (F)
72
67
62
47.0
38.1
36.5
23.0
25.4
32.9
4.28
3.92
3.88
44.3
40.0
35.2
22.1
27.2
33.2
4.49
4.24
4.13
41.7
36.9
33.2
21.2
27.2
32.6
4.70
4.49
4.34
38.8
34.6
31.3
20.3
26.6
31.3
4.89
4.71
4.56

1050/0.08
72
38.8
18.9
3.65
36.9
18.2
3.83
34.9
17.6
4.02
32.8
17.0
4.20

67
35.7
24.5
3.53
33.7
23.8
3.71
31.7
23.0
3.88
29.7
22.4
4.05

1350/0.11
72
39.7
20.3
3.80
37.8
19.9
3.99
35.6
19.1
4.17
33.4
18.5
4.36

67
36.8
27.6
3.70
34.6
26.7
3.87
32.5
25.9
4.03
30.4
25.2
4.21

62
33.5
33.2
3.59
31.8
31.8
3.76
30.2
30.2
3.94
28.5
28.5
4.13

50ZP042
TEMP (F)
AIR ENT
COND

85
95
105
115

BF
Ewb
kW
SHC
TC

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

1225/0.11
72
46.2
22.1
4.19
43.7
21.2
4.39
41.1
20.3
4.60
38.4
19.4
4.81

67
39.0
25.6
3.89
38.4
26.1
4.17
36.5
25.7
4.40
34.2
25.1
4.62

LEGEND
Bypass Factor
Entering Wet Bulb
Total Unit Power Input
Sensible Heat Capacity, 1000 Btuh
Total Cooling Capacity, 1000 Btuh (net)

NOTES:
1. Ratings are net; they account for the effects of the indoor-fan motor
power and heat.
2. Direct interpolation is permissible. Do not extrapolate.
3. The following formulas may be used:
sensible capacity (Btuh)
tldb = t edb
1.10 x cfm

1575/0.14
72
47.5
23.9
4.37
44.7
23.0
4.58
41.9
22.0
4.78
39.1
21.1
4.98

67
37.0
24.8
3.95
38.3
27.8
4.30
37.2
28.5
4.57
35.0
28.1
4.80

62
35.9
33.0
3.93
35.5
34.5
4.21
33.8
33.7
4.44
32.1
32.1
4.68

tlwb = Wet-bulb temperature corresponding to enthalpy of air


leaving indoor coil (h lwb)
hlwb = h ewb total capacity (Btuh)
4.5 x cfm
Where: hewb = Enthalpy of air entering indoor coil
4. The SHC is based on 80 F edb temperature of air entering indoor
coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 BF) x (edb 80).

11

Performance data (cont)


COOLING CAPACITIES (cont)
50ZP048
TEMP (F)
AIR ENT
COND
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

85
95
105
115

62
41.7
37.8
4.34
39.6
37.4
4.60
37.1
36.4
4.85
34.6
34.6
5.09

EVAP AIR CFM/BF


1600/0.07
Evap Air Ewb (F)
72
67
62
43.2
42.2
41.5
19.8
28.4
38.9
4.42
4.42
4.42
45.9
45.5
40.1
22.1
32.1
39.5
4.89
4.86
4.72
45.8
41.5
38.0
23.9
32.0
38.0
5.33
5.14
4.98
42.9
38.5
35.7
23.4
31.2
35.7
5.59
5.38
5.25

62
54.5
48.2
5.80
52.4
47.8
6.21
49.5
46.9
6.60
46.3
45.6
6.97

EVAP AIR CFM/BF


2000/0.07
Evap Air Ewb (F)
72
67
62
63.4
63.0
52.8
30.0
44.1
47.4
6.23
6.30
5.82
65.3
59.0
53.0
32.4
43.2
50.7
6.90
6.72
6.35
62.5
55.7
50.4
32.0
41.2
49.8
7.38
7.01
6.76
58.5
52.5
47.7
30.5
40.4
47.6
7.75
7.43
7.17

1400/0.06
72
45.0
20.7
4.42
46.7
22.8
4.88
45.5
23.1
5.23
42.6
22.3
5.48

67
43.8
29.4
4.41
43.6
30.8
4.77
41.1
30.1
5.03
38.1
29.2
5.26

1800/0.08
72
41.5
19.8
4.44
43.6
21.4
4.90
45.1
24.1
5.38
43.2
24.4
5.70

67
40.7
27.6
4.44
42.7
32.1
4.90
41.7
33.7
5.25
38.7
33.0
5.49

62
40.1
37.4
4.44
40.5
40.4
4.83
38.9
38.8
5.12
36.7
36.6
5.39

50ZP060
TEMP (F)
AIR ENT
COND

85
95
105
115

BF
Ewb
kW
SHC
TC

TC
SHC
kW
TC
SHC
kW
TC
SHC
kW
TC
SHC
kW

1750/0.06
72
65.5
30.8
6.22
65.0
31.4
6.78
61.7
30.4
7.22
57.9
29.2
7.60

67
62.2
41.7
6.16
58.6
40.5
6.55
55.3
39.0
6.87
51.7
37.8
7.27

LEGEND
Bypass Factor
Entering Wet Bulb
Total Unit Power Input
Sensible Heat Capacity, 1000 Btuh
Total Cooling Capacity, 1000 Btuh (net)

NOTES:
1. Ratings are net; they account for the effects of the indoor-fan motor
power and heat.
2. Direct interpolation is permissible. Do not extrapolate.
3. The following formulas may be used:
sensible capacity (Btuh)
tldb = t edb
1.10 x cfm

12

2250/0.08
72
61.2
29.2
6.23
64.3
32.5
6.95
62.9
33.2
7.51
58.9
31.8
7.88

67
63.7
46.5
6.43
60.3
45.7
6.86
56.0
43.2
7.14
52.8
42.9
7.57

62
50.8
46.1
5.84
53.1
52.3
6.47
51.4
51.3
6.93
49.0
49.0
7.37

tlwb = Wet-bulb temperature corresponding to enthalpy of air


leaving indoor coil (h lwb)
hlwb = h ewb total capacity (Btuh)
4.5 x cfm
Where: hewb = Enthalpy of air entering indoor coil
4. The SHC is based on 80 F edb temperature of air entering indoor
coil.
Below 80 F edb, subtract (corr factor x cfm) from SHC.
Above 80 F edb, add (corr factor x cfm) to SHC.
Correction Factor = 1.10 x (1 BF) x (edb 80).

WET COIL PRESSURE DROP


UNIT SIZE
50ZP

024

030

036

042

048

060

AIRFLOW
(cfm)
600
700
800
900
900
1000
1200
1000
1200
1400
1600
1000
1200
1400
1600
1400
1600
1800
1700
1800
2100
2300

PRESSURE DROP
(in. wg)
0.02
0.05
0.06
0.07
0.06
0.06
0.08
0.07
0.09
0.11
0.12
0.04
0.06
0.08
0.09
0.07
0.08
0.09
0.07
0.08
0.09
0.10

FILTER PRESSURE DROP (in. wg)


UNIT
FILTER
CFM
SIZE
SIZE
500
600
700
800
900
1000
1100
1200
1300
1400
1500 1600 1700 1800 1900 2000 2100 2200 2300
50ZP
(in.)
024-042 24 24 0.06 0.07 0.08 0.08 0.09 0.09 0.09 0.10 0.11 0.12 0.14 0.15

048,060 24 30

0.08 0.09 0.10 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18

ACCESSORY ELECTRIC HEAT PRESSURE DROP (in. wg)

Heater kW
5-20

600
0.06

800
0.08

1000
0.10

1200
0.13

CFM
1400
0.15

1600
0.18

1800
0.20

2000
0.23

2200
0.25

13

Performance data (cont)


DRY COIL AIR DELIVERY* HORIZONTAL DISCHARGE (Deduct 10% for 208 Volt Operation)
UNIT
50ZP

024

MOTOR
SPEED

AIR
DELIVERY

Low

Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM
Watts
CFM

Med
High
Low

030

Med
High
Low

036

Med
High
Low

042

Med
High
Low

048
High
Low
060

Med
High

0.1
288
875
390
1131
528
1391
288
875
390
1131
528
1891
470
1302
450
1231
660
1700
478
1303
481
1310

890
1834
1040
2230
1073
2230

0.2
285
820
383
1090
520
1338
285
820
383
1090
520
1338
450
1264
435
1218
635
1660
458
1270
468
1280
798
1736

850
1820
1018
2202
1038
2102

208 AND 460 VOLT HORIZONTAL DISCHARGE


External Static Pressure (in. wg)
0.3
0.4
0.5
0.6
0.7
282
279
274
268
261
802
734
668
582
478
378
369
360
350
340
1038
978
917
830
721
510
495
480
460
450
1285
1200
1115
1018
920
282
279
274
268
261
802
734
668
582
478
378
369
360
350
340
1038
978
917
830
721
510
495
480
460
450
1285
1200
1115
1018
920
445
410
388
359
326
1204
1120
1008
950
863
420
400
380
345
338
1205
1163
1081
940
873
610
575
540
505
485
1581
1450
1297
1190
1095
440
411
378
350
327
1224
1179
1126
1022
911
450
438
404
370
338
1241
1181
1110
1022
943
678
647
618
578
540
1688
1618
1510
1421
1309
801
760
730
688
650
1898
1841
1757
1682
1564
870
842
818
782
696
2000
1903
1799
1718
1625
810
790
735
680
580
1791
1762
1703
1640
1415
1001
958
896
840
800
2160
2122
2052
1926
1752
1000
950
890
835
790
2025
1960
1901
1855
1791

*Air delivery values are based on operating voltage of 230 v or 460 v,


dry coil, without filter or electric heater. Deduct wet coil, filter, and electric heater pressure drops to obtain external static pressure available
for ducting.
460-v motors have 2 speeds (size 060 only).

14

0.8

311
751
321
783
460
989
317
816
320
811
500
1187
600
1429
632
1446
480
1159
650
1468
691
1588

0.9

460
1060
570
1365
628
1333
422
950
580
1121
575
1202

NOTES:
1. Do not operate the unit at a cooling airflow that is less than 350 cfm
for each 12,000 Btuh of rated cooling capacity. Evaporator-coil frosting may occur at airflows below this point.
2. Dashes indicate portions of the table that are beyond the blower motor capacity or are not recommended.

Electrical data
VOLTAGE
RANGE
Min
Max

COMPRESSOR

OFM

IFM

RLA

LRA

FLA

FLA

208/230-1-60

187

254

10.9

61.0

0.9

2.4

208/230-1-60

187

254

15.2

69.4

1.5

2.4

208/230-1-60

187

254

15.9

86.0

1.5

2.8

208/230-3-60

187

254

8.9

64.5

1.5

2.8

208/230-1-60

187

254

18.5

97.6

1.5

2.8

208/230-3-60

187

254

10.9

73.0

1.5

2.8

208/230-1-60

187

254

21.3

107.0

1.5

4.2

208/230-3-60

187

254

12.3

73.0

1.5

4.2

230-1-60

207

254

26.9

128.0

1.4

6.2

208/230-3-60

187

254

17.7

128.0

1.4

6.2

460-3-60

414

508

9.0

63.0

0.7

3.2

UNIT
50ZP

NOMINAL
VOLTAGE
(V-Ph-Hz)

024

030

036

042

048

060

FLA
HACR
IFM
LRA
MCA
MOCP
NEC
OFM
RLA

LEGEND
Full Load Amps
Heating, Air Conditioning and Refrigeration
Indoor (Evaporator) Fan Motor
Locked Rotor Amps
Minimum Circuit Amps
Maximum Overcurrent Protection
National Electrical Code
Outdoor (Condenser) Fan Motor
Rated Load Amps

*Heater capacity (kW) is based on heater voltage of 208 v, 240 v, or


480 v. If power distribution voltage to unit varies from rated heater voltage, heater
kW will vary accordingly.
Fuse or HACR circuit breaker.
NOTES:
1. In compliance with NEC requirements for multimotor and combination load and
equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.
2. Unbalanced 3-Phase Supply Voltage
Never operate a motor where a phase imbalance in supply voltage is greater
than 2%. Use the following formula to determine the percentage of voltage
imbalance.
% Voltage Imbalance
max voltage deviation from average voltage
= 100 x
average voltage

ELECTRIC HEAT
Nominal kW*
/
3.8/ 5.0
7.5/10.0
/
3.8/ 5.0
7.5/10.0
11.3/15.0
/
3.8/ 5.0
7.5/10.0
11.3/15.0
15.0/20.0
/
3.8/ 5.0
7.5/10.0
11.3/15.0
15.0/20.0
/
3.8/ 5.0
7.5/10.0
11.3/15.0
15.0/20.0
/
3.8/ 5.0
7.5/10.0
11.3/15.0
15.0/20.0
/
11.3/15.0
15.0/20.0
/
3.8/ 5.0
7.5/10.0
11.3/15.0
15.0/20.0

20.0
/
3.8/ 5.0
7.5/10.0
11.3/15.0
15.0/20.0

5.0
10.0
15.0
20.0

FLA
/
18.1/20.8
36.1/41.7
/
18.1/20.8
36.1/41.7
54.2/62.5
/
18.1/20.8
36.1/41.7
54.2/62.5
72.2/83.3
/
10.4/12.0
20.8/24.1
31.3/36.1
41.7/48.1
/
18.1/20.8
36.1/41.7
54.2/62.5
72.2/83.3
/
10.4/12.0
20.8/24.1
31.3/36.1
41.7/48.1
/
54.2/62.5
72.2/83.3
/
10.4/12.0
20.8/24.1
31.3/36.1
41.7/48.1

83.3
/
10.4/12.0
20.8/24.1
31.3/36.1
41.7/48.1

6.0
12.0
18.0
24.1

POWER SUPPLY
MCA
16.9/ 16.9
25.6/ 29.0
48.1/ 55.1
22.9/ 22.9
25.6/ 29.0
48.1/ 55.1
70.7/ 81.1
24.2/ 24.2
26.1/ 29.5
48.6/ 55.6
71.2/ 81.6
93.6/107.7
15.4/ 15.4
16.5/ 18.5
29.6/ 33.6
42.6/ 48.6
55.6/ 63.6
27.4/ 27.4
27.4/ 29.5
48.6/ 55.6
71.2/ 81.6
93.8/107.7
17.9/ 17.9
17.9/ 18.5
29.6/ 33.6
42.6/ 48.6
55.6/ 63.6
32.3/ 32.3
72.9/ 83.4
95.5/109.4
21.1/ 21.1
21.1/ 21.1
31.3/ 35.3
44.3/ 50.4
57.4/ 65.4
41.2
111.9
29.7/ 29.7
29.7/ 29.7
33.8/ 37.8
46.8/ 52.9
59.9/ 67.9
15.2
15.2
19.0
26.6
34.1

MOCP
20/ 20
30/ 30
50/ 60
30/ 30
30/ 30
50/ 60
80/ 90
30/ 30
30/ 30
50/ 60
80/ 90
100/110
20/ 20
20/ 20
30/ 35
45/ 50
60/ 70
35/ 35
35/ 35
50/ 60
80/ 90
100/110
25/ 25
25/ 25
30/ 35
45/ 50
60/ 70
40/ 40
80/ 90
100/110
25/ 25
25/ 25
35/ 40
45/ 60
60/ 70
50
125
35/ 35
35/ 35
35/ 40
50/ 60
60/ 70
20
20
20
30
35

DISCONNECT
SIZE
FLA
LRA
16/ 16
24/ 27
68
44/ 51
22/ 22
24/ 27
79
44/ 51
65/ 75
23/ 23
24/ 27
45/ 51
96
66/ 75
86/ 99
15/ 15
15/ 17
27/ 31
74
39/ 45
51/ 59
26/ 26
26/ 27
45/ 51
107
66/ 75
86/ 99
17/ 17
17/ 17
27/ 31
83
39/ 45
51/ 59
31/ 31
67/ 77
121
88/101
21/ 21
21/ 21
29/ 32
87
41/ 46
53/ 60
40
141
103
29/ 29
29/ 29
31/ 35
146
43/ 49
55/ 62
15
15
18
71
24
31

Example: Supply voltage is 460-3-60


AB = 452 v
BC = 464 v
AC = 455 v
452 + 464 + 455
3
= 457
Determine maximum deviation from average voltage:
(AB) 457 452 = 5 v
(BC) 464 457 = 7 v
(AC) 457 455 = 2 v
Maximum deviation is 7 v.
Determine percentage of voltage imbalance:
7
% Voltage imbalance = 100 x
457
= 1.53%
This amount of phase imbalance is satisfactory as it is below the maximum
allowable 2%.
Average voltage =

IMPORTANT: If the supply voltage phase imbalance is more than 2% contact your local electric utility company immediately.

15

Controls
Sequence of operation
Cooling
NOTE: With the FAN switch in the ON position, 24 v is
supplied to the indoor-fan relay (IFR) through the G terminal on the thermostat. This voltage energizes the coil of the
contactor, closing the normally-open set of contracts which
provide continuous power to the indoor-fan motor (IFM).
Moving the FAN switch back to the AUTO. position, providing there is not a call for cooling, deenergizes the IFR,
opens the IFR contacts, and deenergizes the IFM. The FAN
switch in AUTO. position cycles upon a call for cooling.
On a call for cooling, 24 v is supplied to the compressor
contactor (C) and IFR simultaneously through the Y and G
terminals of the thermostat, respectively. On units with a
compressor time delay relay, there is a built-in, 5-minute

16

( 45 seconds) delay between compressor starts. Energizing the contactor closes the normally-open set of contacts
supplying power to both the compressor and outdoor-fan
motor (OFM). Energizing the IFR closes the normally-open
set of contacts providing power to the IFM. On the loss of
the call for cooling, 24 v is removed from both the contactor and IFR and opening both the contacts supplying
power to compressor/OFM and IFM.
Heating If accessory electric heaters are installed, on a
call for heat, circuit R-W is made through the thermostat
contacts. Circuit R-G is made which energizes the IFR. If
the heaters are staged, then the thermostat closes a second
set of contacts (W2) when second stage is required. When
thermostat is satisfied, contacts open, deenergizing the heater
relay and the IFR.

Typical installation

Power Wiring
Control Wiring
Outdoor Airflow

*Separate disconnect per NEC


(National Electrical Code) required
for electric heater when singlepoint connection is not used.

Indoor Airflow

Typical wiring diagram


ELECTRIC HEATER WIRING

17

Typical wiring diagram (cont)

LEGEND

18

AWG
C
CAP
COMP
EQUIP
FL
FU
GND
HR

IFM
IFR
IP
OFM
QT
TDR
TRAN

American Wire Gage


Contactor, Compressor
Capacitor
Compressor Motor
Equipment
Fuse Link
Fuse
Ground
Heater Relay
(Strip Heat)
Indoor Fan Motor
Indoor-Fan Relay
Internal Protector
Outdoor-Fan Motor
Quadruple Terminal
Time Delay Relay
Transformer

Field Splice
Marked Wire
Terminal (Marked)
Terminal (Unmarked)
Terminal Block
Splice
Splice (Marked)
Factory Wiring
Field Control Wiring
Field Power Wiring
Accessory or Optional Wiring
To indicate common potential
only, not to represent wiring

Guide specifications
Packaged Rooftop Cooling Unit with Electric Heat Constant Volume Application
HVAC Guide Specifications
Size Range: 2 to 5 Tons, Nominal Cooling
Carrier Model Number: 50ZP
Part 1 General
1.01 SYSTEM DESCRIPTION
Outdoor rooftop/slab mounted, electrically controlled
cooling unit utilizing a reciprocating compressor for
cooling duty and optional electric heaters for heating
duty. Unit shall discharge supply air horizontally as
shown on contract drawings.
1.02 QUALITY ASSURANCE
A. Unit shall be rated in accordance with ARI Standards
210/240-89 and 270-84. Designed in accordance
with UL Standard.
B. Unit shall be UL listed as a total package for safety
requirements.
C. Roof curb shall be designed to conform to NRCA
Standards.
D. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation.
1.03 DELIVERY, STORAGE AND HANDLING
Unit shall be stored and handled per manufacturers
recommendations.
Part 2 Products
2.01 EQUIPMENT
A. General:
Factory assembled single piece cooling unit. Contained within the unit enclosure shall be all factory
wiring, piping, controls, refrigerant charge (R-22), and
special features required prior to field start-up.
B. Unit Cabinet:
1. Unit cabinet shall be constructed of phosphated,
bonderized, zinc-coated pre-painted steel.
2. Basepan made of a single-piece, non-corrosive,
composite material.
3. Indoor blower compartment interior cabinet surfaces shall be insulated with a minimum 12-in. thick,
flexible fiberglass insulation, coated on the air side
with aluminum foil.
4. Cabinet panels shall be easily removable for
servicing.
5. Unit shall have a sloped non-corrosive drain pan
that conforms to ASHRAE Standard 62-89.
6. Unit insulation conforms to ASHRAE Standard
62P.

C. Fans:
1. Indoor Blower (Evaporator Fan):
a. Fan shall be 2- or 3-speed direct drive as
shown on the equipment drawings.
b. Fan wheel shall be made from steel, be double
inlet type, have forward curved blades with a
corrosion resistant finish, and be dynamically
balanced.
2. Outdoor (condenser) fan shall be of the directdriven propeller type with aluminum blades riveted to corrosion resistant steel spiders. It shall be
dynamically balanced, and discharge air vertically
upwards.
D. Compressor:
Fully hermetic; reciprocating type with internal and
external vibration isolation.
E. Coils:
1. Evaporator and condenser coils shall have aluminum plate fins mechanically bonded to seamless
copper tubes with all joints brazed.
2. Tube sheet openings shall be belled to prevent tube
wear.
3. Outdoor coil shall be protected by metal louvered
panels.
F. Refrigerant Components:
1. Refrigerant components shall be of the Acutrol
feed system type.
2. Service gage connections on suction, discharge,
and liquid lines.
3. Ability to route gage hoses through unit side panel.
G. Controls:
Unit shall be complete with self-contained low-voltage
control circuit.
H. Operating Characteristics:
1. Unit shall be capable of starting and running at
115 F ambient outdoor temperature per maximum load criteria of ARI Standard 210-89.
2. Compressor with standard controls shall be capable of operation down to 40 F ambient outdoor
temperature.
I. Electrical Requirements:
All unit power wiring shall enter unit cabinet at a single
location.
J. Motors:
1. Compressor motors shall be of the refrigerant
cooled type with line break thermal and current
overload protection.

19

Guide specifications (cont)


2. All fan motors shall have permanently lubricated
bearings, and inherent automatic reset thermal
overload protection.
3. Outdoor (condenser) fan motor shall be totally
enclosed.
K. Special Features:
1. Low Ambient Package:
Package shall consist of a solid-state control and
condenser coil temperature sensor for controlling
outdoor-fan motor operation, which shall allow unit
to operate down to 0 F outdoor ambient temperature.
2. Heating Section:
a. Equipped with field-installed electric resistance heater(s) of the characteristics shown
in the equipment schedule.
b. Heater elements shall be open wire type, adequately supported and insulated with ceramic bushings.
c. Electric heater packages must provide singlepoint power connection capability.

Carrier Corporation Syracuse, New York 13221

3. Compressor Short Cycle Device:


Solid-state control shall protect compressor by
preventing short cycling.
4. Controls Upgrade Kit:
Contains high and low pressure switches. Kits
shall protect unit from operating at unacceptable
pressures.
5. Outdoor Thermostat:
Allows for staging of electric heaters based on
outdoor-air temperature.
6. Crankcase Heater:
Warms crankcase oil to reduce refrigerant migration and ensure proper compressor lubrication.
7. Thermostat and Subbase:
Provides staged cooling and heating, automatic
(or manual) changeover, fan control.
8. Electronic Programmable Thermostat:
Thermostat provides 2-stage heating and 2-stage
cooling control with remote communication
ability.

1-97

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
Tab 1b 6b

Page 20

Catalog No. 525-002

Printed in U.S.A.

PC 111

Form 50ZP-1PD
Replaces: 50ZP-1APD