You are on page 1of 30

TECHNO-COMMERCIAL PROPOSAL FOR 450 KLD EFFLUENT TREATMENT PLANT

Following are the few salient features of our offer:


1. Our offer is for Design, Detailed engineering, submission of detailed arch. General
arrangement drawings, Civil Construction, Supply of Electro mechanical Units &
Equipments, Erection and Commissioning.
2. Our technical proposal consists of Physical, Chemical and biological treatment process to
treat 450 KLD of effluent.
3. Proposed biological treatment is anaerobic followed by aerobic system i.e., UASB and ASP.
We proposed anaerobic system followed by BT and ASP to minimize Power consumption.
4. We considered standby arrangements for pumps, blowers etc. to ensure continuous and
smooth plant operation.
5. For disinfection of treated Effluent we proposed Chlorination system.
6. At the time of detailed engineering, based on site conditions, location, technology and
other parameters there may be small changes/modifications in the process, sizes &
volumes of civil units, change of capacities or drives of electro mechanical equipments etc.
for the betterment of treatment process.

7. Following are the assumptions we have considered while preparing the offer and any
change may affect civil costing:

Inlet to first unit is by gravity at NGL-0.00 or by pump


Water, electricity, access road for heavy vehicle available to proposed ETP site.
Soil Bearing Capacity is not less than 25 Tons/M2
Soil type is not black cotton or loose. Water table is below 30 meters. No bailing of
water is required while excavation or no pile foundation required while construction.
Soil type is not rocky or very hard and blasting not required.
Suitable place is available for extra excavated soil for disposal near 50 meters lead.

TECHNICAL OFFER FOR


EFFLUENT TREATMENT PLANT
OF 450 KLD CAPACITY

SECTION -I
1.0.

DESIGN DATA

I)

FLOW

450 m3/day.

II)

SOURCE OF EFFLUENT

Effluent from Process & Washings

III)

TREATMENT PLANT
CAPACITY

19 M3 / Hr.

IV)

RAW EFFLUENT CHARACTERISTICS


Parameter
pH
TSS
COD
BOD
TDS
Oil & Grease

V)

:
Unit

Value

mg/lt.
mg /lt.
mg /lt.
mg /lt.
mg /lt.

4
10500
33500
20350
27500
15

TREATED EFFLUENT CHARACTERISTICS

Parameter

Unit

pH
-Suspended Solids
mg/lt.
COD
mg /lt.
0
BOD 3 days at 27 C
mg /lt.
TDS
mg /lt.
Oil & Grease
mg /lt.
^Inorganic TDS may interfere in the value of COD
^^If Inorganic TDS is < 2100 ppm in raw effluent.
VI)
DESIGN OF ETP PROCESS

Value

7.0 to 8.0
< 30
< 250^
< 100
< 2100^^
< 10

Proposed Effluent Treatment Plant will treat 450,000 liters per day waste water by
Physical, Chemical and Biological process.
Scheme for biological treatment is anaerobic treatment followed by aerobic treatment.

SECTION -II
2.0.

CONCEPT OF UNIT OPERATIONS

I)

CONCEPT FOR ETP


a.
b.
c.
d.
e.
f.
g.

II)

Good quality of treated water.


Under any circumstances stringent pollution control norms are met.
No threat for disposal.
To keep the environment clean & free from contamination.
In future, it is pre- requisite for ISO 14001 Certification / other appreciations.
Minimal electricity consumption, less chemical consumption with low
Operation & maintenance cost and less space.
Save the mother earth for future generations and fulfill social obligations.

PROCESS DESIGN
The process design involves Physical, Chemical and Biological processes.
PHYSICAL AND CHEMICAL PROCESS
Screening, Collection, Equalization, Neutralization, Clarification, Drying.
BIOLOGICAL PROCESS
Converting organic pollutant into harmless by-products with the help of Anaerobic and
Aerobic Microorganisms.
Flow sheet is enclosed for ready reference.
PROPOSED TREATMENT PROCESS SCHEME
Effluent coming from the factory shall be first screened through bar screen chamber.
Over from screen chamber collected in Oil & Scum removal tank. Mechanically Oil &
Scum shall be scraped from Oil & Scum removal tank. By gravity effluent over flow is
collected in Collection cum Equalisation Tank. Floating mixer shall be provided at
equalisation tank for mixing of effluents. From this unit effluent is transferred to Buffer
tank by pump. At Buffer tank suitable chemical solutions are added to neutralise the
effluent. From buffer tank effluent is sent to UASB by pumping. At buffer tank floating
mixer shall be provided for mixing.

BIOLOGICAL TREATMENT
UASB SYSTEM
From buffer tank effluent shall be pumped to Up flow Anaerobic Sludge Blanket Digester
(UASB). Major part of organic load shall be removed here. The anaerobic organisms will
degrade the high concentrated organic matter present in the effluent. In this digester
bacterial granules will be formed which is used as a medium for attachment of
microorganisms, which will in turn convert the complex organic matter into simple
compounds like methane gas, CO2 & H2O. On top of the digester-Gas Liquid Solid
separation system shall be provided.
Gas separately collected in Gas Holder and send to Boiler as a fuel. Excess gas will be
flared with Gas flare system. Necessary safety devises and instrumentation shall be
provided for UASB reactor. The overflow from UASB is sent to the Bio- tower-I.
BIO- TOWERS
Bio tower-I, II have designed as a roughening tower for organic matter reduction from
the influent. Bio tower is constructed with civil columns and beam supports. Bio tower
is filled with PVC structured Bio fill media. The overflow effluent from the UASB, is fed
to the top of the bio tower-I by gravity. At bio tower-I recirculation pumps are
provided to recirculate the effluent from bottom sump to top of the tower to maintain
the surface overflow rate required for the media. The media attached micro-organisms
will degrade the organic matter as BOD in the effluent. One part of the effluent from
recycling feed line is collected at the top of the Bio tower-II. Recycling pumps are also
provided at BT-II for recirculation and also transfer effluent to next unit i.e., Aeration
Tank. Excess biomass on the Bio-tower plastic media is automatically removed due to
the recirculation flow.

ASP SYSTEM
Activated Sludge Process comprises of Aeration tank followed by Secondary Clarifier,
which are, proposed to meet the requirements. In aeration tank organic load as BOD will
be degraded with the help of cultivated microbial culture. Constant Mixed Liquor
Suspended Solids (MLSS) will be maintained in aeration tank in definite proportions by
recycling the bio sludge trapped by the secondary clarifier. At aeration tank air is
supplied from air blower to supply oxygen for the microorganisms.

Recycling of bio-sludge from secondary clarifier will be done by non-clog, centrifugal,


semi open type continuous duty & suitable capacity sludge re circulation pump. The
overflow from secondary clarifier is collected in chlorine contact tank.
CHLORINE CONTACT TANK
In chlorine contact tank chlorine dosing system is provided to disinfect the harmful
pathogens present in water. Disinfected water from this unit is transferred to Dual
media filter by pumping.
DUAL MEDIA FILTER
As pre-treatment unit Dual Media filter (DMF) is provided before Activated Carbon
Filter. The effluent is pumped to DMF to remove suspended particles, turbidity. DMF is
in MS-EP construction with top and bottom dished ends. Operation of the DMF is
Manual.
ACTIVATED CARBON FILTER
Activated carbon filter shall be provided for reduction of Odor, smell & removal of
chlorine. ACF will have activated carbon granules and water will be passed through this
media. Odor and color will be trapped in the media.
SLUDGE TREATMENT
Excess sludge from Secondary clarifier shall be collected on Sludge Drying Beds for
sludge dewatering manually. Dewatered and dried sludge cakes shall be used as good
manure or for secured land filling.

SECTION -III
3.0.

UNITS & EQUIPMENTS

3.1.

CIVIL UNITS

Sr.
No.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.

3.2.

Sr.
No.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.

Particulars

Quantity

Bar Screen Chamber


Oil & scum Removal Tank
Equalization Tank
Buffer Tank
UASB
Bio Tower
Aeration Tank
Secondary Clarifier
Chlorine Contact Tank
Sludge Drying Bed
Panel room
Foundations for Mechanical units/equipments
Railing, Ladders, Cable Trenches, Earth pits, Puddle pipes &
miscellaneous Jobs

One No
One No.
One No.
One No.
One No.
Two Nos.
One No.
One No.
One No.
Six Nos.
One No.
Lot
Lot

MECHANICAL UNITS / EQUIPMENTS

Particulars
Bar Screen
Oil & scum Scraper Mechanism
ET - Effluent Transfer Pump (1W+1Sb)
Floating Mixer
Chemical Dosing System
UASB Feed Pump (1W+1Sb)
GLS system
UASB Feed Distribution Grid
Bio-fill media
BT Distribution Grid
BT Recycling Pump (2W+2Sb)
Air Blower (2W+1Sb)

Quantity
One No.
One No.
Two Nos.
Two Nos.
Two Nos.
Two Nos.
One Lot.
One Lot.
Lot.
One No.
Four Nos.
Three Nos.

13.
14.
15.
16.
17.
18.
19.
3.3.

Sr.No.
1.

3.4.

Sr.No.
1
2
3
3.5.

Sr.No.
1.
2.
3.
4.
5.
6.

Air Diffusers and Grid


Secondary Clarifier Mechanism
Bio-sludge Recycling Pump (1W+1Sb)
Chlorine Dosing System
Filter Feed Pump ( 1W+1Sb)
Dual Media Filter
Activated Carbon Filter

One Lot.
One No.
Two Nos.
One No.
Two Nos.
One No.
One No.

PIPING & FITTINGS

Particulars
Interconnecting Piping between all proposed ETP
units within battery limits with all necessary Valves &
other fittings.

Quantity

Lot

ELECTRICAL WORKS

Particulars

Quantity

MCC Panel board


Electrical cabling from panel to units of ETP
ETP earthing

One No.
Lot
Lot

INSTRUMENTATION & SAFETY DEVICES

Particulars

Quantity

Pressure Gauges
Liquid Flow Meter
Flame Arrester
Moisture Trap
Pressure Relief Valve
Gas Flare Stack

Lot
One No.
Two Nos.
Two Nos.
Two Nos.
One No.

3.6.

Sr.No.
1.
2.
3.

OPTIONAL UNITS/EQUIPMENTS

Particulars

Quantity

Gas Holder
Gas flow Meter
Gas Blower (1W+1Sb)

One No.
One No.
Two Nos.

10

SECTION -IV
4.0.

TECHNICAL SPECIFICATIONS FOR UNITS & EQUIPMENTS

4.1.

CIVIL UNITS / WORKS

1.

2.

BAR SCREEN CHAMBER


Type
MOC
Volume
Quantity

:
:
:
:

Rectangular
RCC M30
0.60 M3
One No.

OIL & SCUM REMOVAL TANK


Type
MOC
Volume
Quantity

:
:
:
:

Rectangular
RCC M30
12 M3
One No.

3.

COLLECTION & EQUALISATION TANK


Type
: Rectangular / Square
MOC
: RCC M30
Volume
: 150 M3
Quantity
: One No.

4.

BUFFER TANK
Type
MOC
Volume
Quantity

:
:
:
:

Rectangular / Square
RCC M30
36 M3
One No.

UASB REACTOR
Type
MOC
Volume
Quantity

:
:
:
:

Circular
RCC M30
1510 M3
One No.

BIO-TOWERS
Type
MOC
Area
Quantity

:
:
:
:

Rectangular / Square
RCC M30
36 M2
Two Nos.

5.

6.

11

7.

8.

9.

10.

11.

AERATION TANK
Type
Volume
MOC
Quantity

:
:
:
:

Rectangular / Square
810 M3
RCC M30
One No

SECONDARY CLARIFIER
Type
MOC
Volume
Quantity

:
:
:
:

Circular
RCC M30
90 M3
One No.

CHLORINE CONTACT TANK


Type
MOC
Volume
Quantity

:
:
:
:

Rectangular
RCC M30
45 M3
One No.

SLUDGE DRYING BEDS


Type
MOC
Area
Quantity

:
:
:
:

Square
BBM
30 M2
Six Nos

MCC PANEL ROOM


Type
Area
MOC
Quantity

:
:
:
:

Square / Rectangular
20 M2
BBM
One No.

12.

FOUNDATIONS FOR ELECTROMECHANICAL UNITS


Type
: Rectangular/Square/Circular
Quantity
: Lot

13.

PUDDLE PIPES, LADDERS, RAILING, MANHOLES, EARTH PITS, PIPING SUPPORTS &
CABLE TRENCHES ETC.
MOC
: Ladders-MS, Railing-MS/GI, Puddle Pipes
MS/uPVC
Painting
: As required
Quantity
: Lot

12

4.2.
1.

MECHANICAL UNITS
BAR SCREEN
Type
MOC
Size
Quantity
Application
Location

:
:
:
:
:
:

Manual
SS304
Suitable to Civil Unit
One No.
Screening of floatable solids
Screen Chamber

2.

OIL & SCUM REMOVAL MECHANISM


Type
: Semi Automatic & Scraping type
Rated Power
: 0.5 HP
Quantity
: One No.
Motorized trolley with four wheels anti friction bearing, travel to & fro on MS rails.
Having electrical limit switches on either side. Neoprene rubber skimmer plate.
Control panel consist of air break reversing contractors, timer etc. Push button cable,
flexible cable, drive consist of gear/ motor.

3.

ET - EFFLUENT TRANSFER PUMP


Type
MOC
Capacity
Head
Drive
Quantity
Application
Location

:
:
:
:
:
:
:
:

Centrifugal, Self priming


SS Internals with CI body
19 M3/Hr
10 Meters
3.0 HP
2Nos (1 W + 1 S )
For Effluent transfer to Buffer Tank
At Equalization Tank

FLOATING MIXER
Type of mixer
Drive
MOC
Quantity
Application
Location

:
:
:
:
:
:

Slow speed
5 HP & 2 HP
SS
Two Nos.
For mixing
At Equalization Tank &Buffer Tank

CHEMICAL DOSING SYSTEM


Type of tank
MOC of tank
Tank Capacity

:
:
:

Cylindrical Vertical
HDPE
200 Liters

4.

5.

13

6.

7.

8.

9.

Pump capacity
MOC of pump internals
Quantity
Application
Location

:
:
:
:
:

0 to 30 LPH
PP/SS
Two Nos.
For Neutralization
Near Buffer Tank

UASB FEED PUMP


Type
MOC
Capacity
Head
Drive
Quantity
Application

:
:
:
:
:
:
:

Centrifugal, Self priming


SS Internals with CI body
19 M3/Hr
12 Meters
3.0 HP
2Nos (1 W + 1 S )
Effluent Feed to UASB

Location

At UASB Reactor

GLS SYSTEM
Application
Location
MOC
Quantity

:
:
:
:

Gas Liquid, Solids separation


UASB Reactor top
MS-FRP/MS-PU coating
One Lot

UASB FEED DISTRIBUTION GRID


Type
:
MOC
:
Quantity
:
BIO FILLS
Location
MOC
Specific Surface Area
Void Ratio ( M2 / M3 )
Thickness
Standard Dimensions
Max. width of support
Dry weight
Quantity

10.

:
:
:

BIO-TOWERS DISTRIBUTION GRID


Type
:
MOC
:

Perforated, Piping distribution for effluent


uPVC
One Lot

Medium for Bacterial attachment due to


contact time of bacteria & effluent increases.
PVC
93 M2 / M3
More than 97 %
0.6 mm & 0.3 mm
1200x 600 x 600 mm
100 / 50 mm
20 kg / m3
Lot

Perforated, Piping distribution for effluent


uPVC

14

Quantity
11.

12.

13.

14.

BIO TOWERS RECYCLING PUMP


Type
:

One Lot

Capacity
Drive

:
:

MOC
Accessories

:
:

Quantity

Self priming , Centrifugal, non-clog, Semi-open


impeller
54 M3/Hr X 10 M Head
5.0 HP (each) motor, 3 phase,
2900 rpm,
TEFC class F insulation with IPP 55
protection, weather proof.
CI
Fabricated MS base-plate, coupling guard ,
foundation bolts etc.
Four Nos ( 2 W + 2 Sb)

AIR BLOWERS
Type
Media Handled
Air Flow
Delivery Pressure
Duty
Cooling
Motor HP
Accessories
Quantity
Application
Location

:
:
:
:
:
:
:
:
:
:
:

Twin lobe, Roots


Air
450 M3/hr.
0.45 kg/cm2
Continuous
Air Cooled
15
All accessories as per requirement
Three Nos.(2W+1Sb)
Providing air
Near Aeration Tank

AIR DIFFUSERS & GRID


Type
MOC
Size
Air flow-Max.
Quantity
Application

:
:
:
:
:
:

Grid MOC
Location

:
:

Fine membrane type air diffuser


EPDM
67mm OD x 2000 mm length
16 M3/Hr.
Lot
Transferring the Oxygen to water in fine
bubbles.
uPVC
At Aeration Tank

SECONDARY CLARIFIER MECHANISM


Application
: To scrap the settled sludge at the bottom of
clarifier & to collect sludge in center chamber.
Location
: At Secondary Clarifier.

15

15.

16.

Size
Access Bridge

:
:

Suitable to civil unit.


The full span structural bridge with 1000 mm
width at center & 5 mm thick chequered plate
up to full length, with hand railing.
0.5 H.P
Centre drive
Elicon /Crompton /Siemens
MS epoxy painted the center pipe having
two scraper arms with neoprene rubber
squeegees. The floor is scraped twice in
revaluation to collect sludge at the center.
Turn buckles to be provided with central shaft
for adjustment of scrapper slope.
MS-epoxy painted feed well, supported from
the bridge, with baffle plate.
All wetted parts will have one coat of epoxy
primer & two coats of epoxy paints. Above
water parts will have two coats of synthetic
enamel paint.
One no.

Motor
Drive
Gear Box & Motor
Scraping

:
:
:
:

Feed well

Painting

Quantity

BIO SLUDGE RECYCLING PUMP


Type

Capacity
Drive

:
:

MOC
Accessories

:
:

Quantity

Self priming , Centrifugal, non-clog, Semi-open


impeller
19 M3/Hr X 10 M Head
3.0 HP (each) motor, 3 phase,
2900 rpm,
TEFC class F insulation with IPP 55
protection, weather proof.
CI
Fabricated MS base-plate, coupling guard ,
foundation bolts etc.
Two Nos ( 1 W + 1 Sb)

CHLORINE DOSING SYSTEM


Type of tank
MOC of tank
Tank Capacity
Quantity
Pump capacity
MOC of pump
Quantity
Application
Location

:
:
:
:
:
:
:
:
:

Cylindrical, Vertical
HDPE
200 Liters
One No.
0 to 10 LPH
PP/SS
One No.
For Disinfection
Near Chlorine Contact Tank

16

17.

18.

19.

4.3.
1.

FILTER FEED PUMP


Type
MOC
Capacity
Head
Drive
Quantity
Application
Location

:
:
:
:
:
:
:
:

Monoblock, Centrifugal
CI
22.5 M3/Hr
30 Meters
5.0 HP
2 Nos (1 W + 1 S )
Feed to Dual Media Filter
Chlorine Contact Tank

DUAL MEDIA FILTER


Type
MOC
Feed Flow
Size
Media
Quantity
Application
Location

:
:
:
:
:
:
:
:

Vertical ,Cylindrical
MSEP
22.5 M3/Hr.
Suitable
Sand, Pebbles, Gravel, Anthracite
One No.
Removal of SS
After Chlorine Contact Tank

ACTIVATED CARBON FILTER


Type
: Vertical ,Cylindrical
MOC
: MSEP
Feed Flow
: 22.5 M3/Hr.
Size
: Suitable
Media
: Carbon
Quantity
: One No.
Application
: Removal of odor/color
Location
: After DMF
PIPING & FITTNGS
INTER CONNECTING PIPING & FITTINGS
MOC
: MS-C class Pressure Lines / Above Water
Lines
uPVC-10Kg Pressure for Gravity Lines / Air Lines
/ Below Water Lines.
Painting
: External protection for MS piping
Size
: As required
Fittings
: As required
Valves
: Diaphragm/Butterfly
Quantity
: Lot

17

4.4.
1.

2.

3.

ELECTRICAL WORKS
MCC PANEL
Type
MOC
Painting
Size
Mounting

:
:
:
:
:

Incomer with

Quantity

Compartmental
14 swg / 16 swg CRCA sheet
Painting and surface coating as required.
As per design
Floor mounting, cable entry at bottom/top with
back access
Ammeter, Volt meter, Digital type energy
meter
One No.

ELECTRICAL CABLING
Type
MOC
Size
Quantity

:
:
:
:

Armored
Copper/Al
As per design-suitable capacity
One lot

EARTHING
Type
MOC
Quantity

:
:
:

Wire/flat
GI wire/Flat,CU Plate
One Lot

PRESSURE GAUGE
Location
Application
Make
Type
Dial Size
Range
Quantity

:
:
:
:
:
:
:

Delivery side of pump


Measure pressure of liquid
Wika / H-Guru
Dial /Bourdan
Suitable
0 to 4 kg / cm2
Lot

LIQUID FLOW METER


Type
Application

:
:

Electromagnetic
To measure the flow

4.5. INSTRUMENTATION & SAFETY DEVICES


1.

2.

18

3.

4.

5.

6.

Flow range
Qty.

:
:

0 to 20 M3/Hr
One No.

FLAME ARRESTOR
Quantity
Application
Location
Size
MOC

:
:
:
:
:

Two Nos.
To arrest flames
Gas pipeline
Suitable as per design
MS/SS

MOISTURE TRAP
Quantity
Application
Location
MOC
Size
Drain valve
Process medium

:
:
:
:
:
:
:

Two Nos.
To trap the moisture
Gas pipeline
MS epoxy
Suitable as per design
To be provided
Biogas

PRESSURE RELIEF VALVE


Quantity
Application
Location
Size
MOC

:
:
:
:
:

Two Nos
To relieve pressure
Top of the Digester
Suitable
CI

GAS FLARE STACK


Quantity
Application
Location
MOC
Size
Ignition System

:
:
:
:
:
:

One No.
To flare the biogas
At one corner of ETP plant
MS-EP Basin with MS C and SS pipe as flare
Suitable as per design
Manual

19

4.6.
1.

2.

3.

OPTIONAL UNITS/ EQUIPMENTS


GAS HOLDER
Quantity
Size
Application
Location
MOC

:
:
:
:
:

One No.
Suitable
To store the gas
Near Digester
MS & RCC

GAS FLOW METER


Quantity
Flow
Location

:
:
:

One No.
200 M3/Hr.
Feed to Boiler

GAS BLOWERS
Quantity
Medium Handled
Gas Flow
Duty

:
:
:
:

Two Nos. (1W+1Sb)


Biogas
200 M3/hr.
Continuous

20

SECTION -V
5.0.

ELECTRICAL LOAD LIST

SR.NO. UNIT / EQUIPMENT


1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.

Oil & Scum Mechanism


ET - Effluent Transfer Pump
Floating Mixer-ET
Floating Mixer-BT
Chemical Dosing System
UASB Feed Pump
BT Recycling Pump
Air Blower
SC Mechanism
Bio-sludge Recycling Pump
Chlorine Dosing System
Filter Feed Pump

Total Working Load HP

QTY.
One No.
Two Nos.
One No.
One No.
Two Nos.
Two Nos.
Four Nos.
Three Nos.
One No.
Two Nos.
One No.
Two Nos.

WORKING LOAD
HP
0.5
3.0
5.0
2.0
1.0
3.0
10.0
30
0.5
3.0
0.5
5.0

STAND BY LOAD
HP
3.0

3.0
10.0
15
3.0
5.0

63.5 HP ( 47.63 KW)

21

SECTION -VI
6.0

PERFORMANCE ON THE BASIS OF BOD

6.1.

RAW EFFLUENT CHARACTERISTICS

PARAMETER

UNIT

VALUE

BOD

Mg/lt.

20500

PARAMETER

UNIT

VALUE

BOD

Mg/lt.

< 100

6.2. TREATED EFFLUENT CHARACTERISTICS

6.3. STAGE WISE REDUCTION OF BOD


S. No.

Treatment System

BOD
% Reduction

Raw Effluent

--

Mg/Lt.
Outlet
20500

UASB Treatment

85

3075

Aerobic Treatment
BT System
Aerobic Treatment
ASP System
Tertiary system

70

923

95

47

<30

c
d

22

SECTION -VII
7.0.

LIST OF STANDARD MAKES


UNIT/ EQUIPMENT

MAKES

Fabricated items
Air Diffusers
Air Blower
Motors
Effluent Pumps
Dosing System
Piping
Biofills
Panel Components
Cables
Pressure Gauges
Level Switches
Flow meter
Valves

SAI
Rehau ,Germany / SSI-USA/Nipon
Everest /Kay/KPT/Usha
Crompton/Siemens/Kirloskar
Johnson /Kirloskar
SR Metering / E-Dose/Positive Metering
uPVC- Supreme/Finolex/MS-Zindal/TATA
Cool deck / MM Aqua/ Equivalent
Siemens / L & T/Schneider/Equivalent
Fine cab/Polycab
H Guru/Waree
Techtrol/Fisher
Forbes Marshall /E & H
Intervalve/ Omkar/BDK/Equivalent

23

SECTION -VIII
8.0. SCHEDULE OF EXCLUSIONS
Plant/Area Lighting.
Unloading of the equipments at your factory and transportation to the ETP Site/ Area.
All consumable oil, grease, chemicals for testing and commissioning.
Charging of electric panel. Wiring, lighting and other fixtures in panel room./sheds
All apparatus, chemicals, materials and other necessary equipment required for
laboratory for analysis.
Arrangements to bring the influent up to the battery limits of the treatment plant as
well as the treated effluent from the treatment plant to the final discharge.
Water, electricity and other utilities at one centre point of ETP for Erection, Fabrication,
Testing and Commissioning.
Water pipeline arrangement for dosing systems
Skilled or unskilled Manpower, Tools & tackles, Operators, Chemicals, Oil & grease,
Nutrients and bacterial culture (cow dung) etc. required at the time of testing &
commissioning.
Approach Roads, Internal Roads, Green belt development, Plant lighting, Security cabin,
Boundary walls, Fencing, Gate and other infrastructure facilities inside and outside the
ETP area
Unloading, Safe Storage for our equipments
Instrument air /Compressed air
All utilities / consumables like chemicals, spares, steam, power, water as required to ETP
as per process requirement to be arranged to battery limit of the units/equipments

24

All civil related works, tanks, foundations, cable trenches, piping support pedestals,
earth pits, earthing, Structural Design & drgs etc.(If civil construction work excluded
from our scope)
Any change in flow & characteristics of effluent.
Any supply which is not specifically mentioned as part of our offer.

25

SECTION - IX
9.0

TERMINATION POINTS

Inlet to First Unit Bar Screen Chamber

Outlet from Last Unit-ACF

Sludge from Sludge Drying Beds

Power supply & charging our supplied ETP panel

26

SECTION -X
10.0. PROJECT SCHEDULE -BAR CHART
Specific Confirmation on project execution schedule.
Time period provided to execute the proposed ETP is 150 days. This ETP project involves
different types of engineering activities with civil, mechanical and electrical works etc.
PROJECT EXECUTION PLAN
WORK OF ETP
Site survey ,design drawings, approval etc.

TIME PERIOD
30 Days

Civil Works
90 Days
Mechanical units/ equipments Delivery at
site
Erection of ETP

30 Days

Total ETP Ready to commission

150 Days

27

SECTION -XI
11.0. PRICE, TERMS & CONDITIONS
PRICE

Price for Design, Detailed Engineering, Construction, Supply,


Erection, Testing & Commissioning of 450KLD Effluent Treatment
Plant as per the scope and specifications mentioned in our offer
on turnkey basis shall be:
-

Civil Works
:
Electro-mechanical Supplies :
Service Jobs
:

Rs.1,33,75,000/Rs. 1,36,85,000/Rs. 7,50,000/-

P&F

@ 2%

FREIGHT

Extra to be paid by client at actual

TAXES

VAT and Service tax extra as applicable at the time of billing.

INSURANCE

0.5%

PAYMENT

30 % as advance along with Purchase Order


10 % against drawings approval
55 % and applicable taxes against profarma invoice on prorata
basis for Electro-mechanical equipments and against RA bills for
Civil works- as per submitted billing schedule.
5% after commissioning of ETP or 60 days from the last date of
major supply at site.

DELIVERY

The delivery period will be 150 days time from the date of
receipt of Purchase Order along with advance and clear site to
start work.

VALIDITYOF
OFFER

30 days.

WARRANTY

Mechanical:

28

12 Months from the date of testing or 15 months from the date of


last major supply at site whichever is earlier for any
manufacturing defects. Defect will be rectified. Not applicable for
normal wear and tear.
Process:
12 Months from the date of process commissioning
ERECTION &
COMMISSIONING

:
Suitable lodging, boarding and local conveyance to our engineers
to be provided for two persons.

FORCE MAJEURE

As applicable

EXTRA WORK

Any work not included as a part of our offer or scope shall be


deemed extra. Such works can be done by SEEPL with extra cost
with mutual agreement & understanding.

GENERAL

Any condition not specifically included could be discussed


and mutually agreed upon.

GENERAL TERMS AND CONDITIONS:


DELAY IN COMPLETION:
If the completion work is delayed beyond the contractual value date for reasons under your
control as listed out hereunder but not limited to them, we shall be entitled to suitable
readjustment in the period of completion by mutual consent and the contract will stand
amended to that extent.
a) Delay in approval of drawings/ specifications beyond a period of 7 days
from the date of submission by us.
b) Delay in inspection beyond the appointed date or delay in approval of
test certificates, whenever required, beyond a period of 7 days from the
date of submission by us.
c) Delay in release of dispatch clearance or hold up of work due to your
specific instructions or lack of instruction.
d) Delay in release of advance or progress payments due to us beyond 7
days from the date of bill submission.
e) Delay in arranging manpower, power, effluent, analysis, and water etc as
and when required.
f) Delay attributable to force Majeure conditions, more particularly detailed
under appropriate clause hereunder.

29

ERECTION &COMMISSIONING:
It will be the responsibility of the purchaser to make all the arrangements and provide all
facilities and materials for carrying out erection and pre-commissioning test, before the date of
readiness for such tests as intimated by us. In the event of delay on the part of purchaser in
making these arrangements including operators, water, power, effluent, analysis as per design
basis and consequent delay in erection or commissioning of equipment/ system, the purchaser
will release all such payment, which could have been due to us on erection/commissioning of
equipment/system. Any delay from client for arranging required facilities/materials more than
four weeks from the last major equipment supplied to site, client ahs to release all dues
against erection and commissioning to us.
OPERATING PERSONNEL
The purchaser will ensure that his operating personnel is made available before pre
commissioning to enable them witness all commissioning test and satisfy themselves about all
guarantee parameters.
ORDER CANCELLATION
The purchaser cannot cancel the purchase order without taking written consent from the
Supplier/contractor. For any reason order is cancelled by purchaser advance will be forfeited
and if there is any losses arises due to procurement or work progress at site suitable
compensation to be done by Purchaser.
PAYMENTS
The purchaser will ensure that payments released as per purchase order. Any delay is payments
against submitted bills or work progress Purchaser has to pay @18% interest on unsettled bill
amount on daily calculation basis.

DELAY
For any reason attributed to the Purchaser project delays more than three months from the
date of completion as per the purchase order, mainly due to delay in civil works or delay in
giving clearance for supplies or location finalization etc. Purchaser should amend and
compensate @ 1% increment on Total Price of the Purchase Order for every one month delay
to compensate the price escalations and overheads .

ACCEPTANCE OF THE TREATMENT PLANT


In case the plant is not commissioned after the supply within a period of 30 days due to the
non-availability of Effluent or any other reason. Whatsoever, the plant will be deemed as
successfully commissioned.

30

WAREHOUSING CHARGES
Should dispatches be delayed on our purchasers instructions or any other reason attributable
to purchaser, warehousing expenses shall be payable by the purchaser @ 2% of the
consignment value per month of part thereof.
EXCESS MATERIAL
Since we shall be sending to site a number of items in spare for smooth and uninterrupted
construction, erection and commissioning, such items which remain unused, will be our
property and will be removed by us as and when required.
PRICE BASIS & ESCALATIONS
Our commercial offer is based on present (the date of offer) market rate pricing for Steel,
Cement, Sand, Metal, Labor rates, Piping and electricals, Diesel etc. For any reason major
fluctuations or changes on any particular or total items change of price may impact the project.
Our price will be firm for the committed delivery period however any change due to the delay
of the project attributed to you to be compensating suitably with mutual understanding.
Any changes/amendments related to all taxes, duties and statutory requirements etc. area
applicable at actual at the time of billing.

Our technical offer and commercial offer with all terms, conditions etc should be part of the
Purchase order.