Professional Documents
Culture Documents
Slippery Nylon
Aluminum Alloy
Conductor
Application
Lead-Free PVC
(UL-Listed)
Detailed Description
or Construction
Conductor
AA-8000 series aluminum alloy compact
stranded sizes 6 AWG up to 1000 MCM
Insulation
Premium grade flame retardant Lead-free
UL-listed Polyvinyl Chloride
Jacket
Tough and slippery polyamide (nylon) for
easy-pulling
Standards / Testing
Specifications
Aluminum THHN/THWN-2 meets or exceeds all
applicable ASTM specifications, requirements of
the National Electrical Code, and conforms to the
following standards:
UL83 for Thermoplastic Insulated Wires
and Cables (THHN/THWN-2)
UL758 for Appliance Wiring Materials
(AWM)
UL1063 for Machine Tool Wire (MTW)
www.pdic.com
Executive Office:
2316 2/F Karrivin Plaza, Pasong
Tamo Ext. Makati City, Philippines
T. (632) 813-2529
F. (632) 893-4990
Features
CT Rated Lead-Free THHN/THWN cables
are insulated with special PVC formulation
that makes it more flame retardant than
ordinary THHN cables.
More tolerant to heat with its better flameretardant PVC.
The insulation is made of materials that do
not contain lead as stabilizer making it
Environment Friendly.
Its nylon jacket offers mechanical protection
and resistance to petroleum by-products,
chemical reagents, and oils. It is also
abrasion-resistant, allows higher gliding and
greater ease in installation. Its slippery
property allows easier pulling when stripping.
Available in black, white, red, blue, green,
and yellow colors.
Manufacturing Plant:
Luisita Industrial Park
San Miguel, Tarlac City Philippines
T. (6345) 985-1088 to 91
F. (6345) 985-0076
Insulation
Jacket
Nominal
Size
AWG or
kcmil
Conductor
No. of
Thickness
Thickness
O.D.
Allowable Ampacities*
Wires**
(mils)
(mils)
(mils)
30
239
40
50
40
305
55
40
361
75
18
50
420
1/0
18
50
2/0
18
50
3/0
18
50
4/0
18
50
250
35
300
350
60C
75C
90C
Approx. Net
Weight Per
1000' (lbs.)
60
40
65
75
64
90
100
94
85
100
115
120
456
100
120
135
144
500
115
135
150
176
546
130
155
175
214
599
150
180
205
262
60
665
170
205
230
315
35
60
716
190
230
255
369
35
60
762
210
250
280
422
400
35
60
804
225
270
305
475
500
35
60
883
260
310
350
579
600
58
70
980
285
340
385
703
700
58
70
1045
310
375
420
807
750
58
70
1076
320
385
435
859
900
58
70
1164
355
425
480
1014
1000
58
70
1218
375
445
500
1116
*Allowable Ampacities:
Allowable ampacities shown are for general use as specified by the National Electrical Code, 2008 Edition, table 310-16.
60C When terminated to equipment for circuits rated 100 amperes or less or marked for 10 through 1AWG conductors.
75C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1AWG.
THWN-2 when exposed to oil or coolant.
**For compact-stranded construction, the number of wire as permitted by UL 83 and ASTM B-801 may be reduced as follows:
19-Wire Construction 18 Wires Minimum
37-Wire Construction 35 Wires Minimum
61-Wire Construction 58 Wires Minimum
www.pdic.com
Executive Office:
2316 2/F Karrivin Plaza, Pasong
Tamo Ext. Makati City, Philippines
T. (632) 813-2529
F. (632) 893-4990
Manufacturing Plant:
Luisita Industrial Park
San Miguel, Tarlac City Philippines
T. (6345) 985-1088 to 91
F. (6345) 985-0076