You are on page 1of 5

Instructions for Overriding Dead

Lock Battery using the LPI/ELPS


SAFLOK LPI/ELPS
(Lock Programmer-Interrogator/Emergency Lock Power Supply)

Top View

Bottom View

The SAFLOK LPI/ELPS device is more frequently used for programming and
interrogating locks. However, the device can also be used to open a lock that has a dead
internal battery. Typically a lock with a dead battery will not flash any lights after a
keycard is used. If a lock displays flashing lights after a keycard is used, please consult
your services manual for troubleshooting other conditions.
SAFLOK System Requirements
1.
2.
3.
4.
5.
6.

LPI/ELPS device (Part # 74334)


Male 25DB-Male 25DB parallel cable (Part # 7542380)
6 Download cable (part # 71982)
Handheld module (Part # 701913 with Software Version # 031905 or greater)
PC with a serial port and SAFLOK Client application (Version # 2.36 or greater)
SAFLOK SL2500 ASIC or MT series locks (Software Version # 81305 or
greater)

ELPS\LPI Instr. 1

Instructions for Overriding Dead


Lock Battery using the LPI/ELPS

Procedure
1. Launch and then logon to the SAFLOK Client application. Select the Locks tab.
Select the Program Locks button.

2. The Information box will appear. Before making a selection, connect one end of the
download cable to the serial port on the PC and the other end to the handheld. Select
OK on the Information box.

ELPS\LPI Instr. 2

Instructions for Overriding Dead


Lock Battery using the LPI/ELPS

3. The Select LPI Command window will appear. Select the Override Lock Problem
option and click the OK button.

4. The Ekey Selection window will appear. Click the Emergency key inside the box,
and click the OK button.

ELPS\LPI Instr. 3

Instructions for Overriding Dead


Lock Battery using the LPI/ELPS

5. The SAFLOK Client message box will appear. Click OK. At this point, the
handheld is configured.

6. Now view the HH5 Main Menu screen on the handheld device. Press 2 on the
keypad, which will move the cursor to 2.Take Unit to Locks, then press Enter.
HH5 MAIN MENU
02-18-06 09:09AM DST
2. Take Unit to Locks
3. Setup Menu
7. Screen M254 will appear. Follow the screen instructions and then press Enter.
Additionally, separate the handheld from its base, then take the handheld and
LPI/ELPS to the lock
M254: Disconnect
Terminal Cables and
Connect LPI Probe
**PRESS ANY KEY**

8. On the following screen, Press 6 that will move the cursor to 6. Send ELPS key.
Press Enter.
02-18-06 09:09AM DST
5. Lock Vers/LED Diag
6. Send ELPS key
Select Choice ?
9. Screen M252 will appear. Follow the on screen instruction by pressing Enter.

ELPS\LPI Instr. 4

Instructions for Overriding Dead


Lock Battery using the LPI/ELPS
M252: Press Any Key
and then Insert LPI
Probe into Lock!
(Press ESC to Abort)
10. Screen M251 will display until the LPI/ELPS device is inserted into the lock.
M251: Please Wait
Programming the Lock

11. As soon as screen M236 appears turn the locks handle to open the door.
M236: ELPS is powered
and the lock is open
Please turn handle
Press Any Key
12. After the door has been opened, remove the LPI/ELPS device from the lock. Press
Enter and then ESC on the handheld. The handheld will return to the following
screen. Select 7. Disable ELPS key and then press Enter
02-18-06 09:10AM DST
6. Send ELPS key
7. Disable ELPS key
Select Choice ?
13. At this point the ELPS feature has been disable and the handheld should be returned
to its base.
****Warning***** The battery in the LPI/ELPS device will be drained of its power
if connected to the handheld while the handheld is on its base charger. Please
remove the LPI\ELPS device from the handheld when its not in use.