Professional Documents
Culture Documents
OBJETIVOS:
A partir de datos experimentales de presin y volumen obtenidos por el estudiante en el
laboratorio, demostrar numrica y grficamente la veracidad de la ley de Boyle.
Altura (hc)
(cm)
22.1
21.2
20.1
19.1
17.9
16.6
15.3
hbarm= 0.585 mHg
Altura (ha)
(cm)
26.1
29.4
33
37.1
41.5
46.2
51.4
tamb= 26C
TABLA DE RESULTADOS
Hg
13531.1668 kg/m3
Patm = 77415.5646
Pa
Ri= 0.4575 cm
Kprom =1.7992 Pa m3
haire
(cm)
Vaire
(cm3)
ha
(m)
hc
(m)
hhg
(m)
Ph
(Pa)
Pabs
(Pa)
K
(Pa m3)
Vajustado
(cm3)
33.1
21.765
0
20.384
2
19.134
8
17.819
7
16.636
1
15.518
2
14.400
4
0.261
0.221
0.04
5293.3924
82709.257
1.7753
21.753
0.294
0.212
0.082
88267.391
1.7992
19.590
0.33
0.201
0.129
94487.0552
1.8079
18.300
0.371
0.191
0.18
101236.1306
1.8039
17.772
0.415
0.179
0.232
108117.5408
1.7986
16.641
0.462
0.166
0.295
116454.6339
1.8071
15.449
0.514
0.153
0.361
10851.454
5
17071.190
6
23820.266
0
30701.676
2
39038.769
3
47772.866
8
125188.7314
1.8027
14.371
31
29.1
27.1
25.3
23.6
21.9
Clculos
Ri= Di/2
Ri= 0.915 cm/2= 0.4575 cm
4.575 x 10-3 m
haire= hT-hc
haire(1)= 55.2 cm 22.1 cm= 33.1 cm
0.331 m
0.31 m
0.291 m
0.271 m
0.253 m
0.236 m
0.219 m
3.- Calcula los valores del volumen de aire (Vaire) en cm 3 y transforma los
resultados a m3.
Recuerda: 1 m 3= 1x106 cm3
Vaire= () (Ri)2 (haire)
Vaire(1)= () (4.575x10-3)2 (0.331 m)= 2.1465x10-5 m3
Vaire(2)= () (4.575x10-3)2 (0.31 m)= 2.0384x10-5 m3
Vaire(3)= () (4.575x10-3)2 (0.291 m)= 1.9134x10-5 m3
Vaire(4)= () (4.575x10-3)2 (0.271 m)= 1.7819x10-5 m3
4.- Calcula la densidad del mercurio (Hg) en kg/m3, con la siguiente expresin.
CDMX)
Patm= (Hg)(g)(hbarom)
Patm= (13531.166Kg/m^3)(9.78 m/s^2)(0.585 mHg)= 77415.8646 Pa
aire
K=P
5
= 1.7753 Pa m3
= 1.7992 Pa m3
= 1.8079 Pa m3
= 1.8039 Pa m3
= 1.7986 Pa m3
= 1.8071 Pa m3
= 1.8027 Pa m3
K
N
K ( 12.5947 ) Pa m3
K=
=
N
K= 1.7992 Pa m3
12.- Calcula los valores del volumen ajustado del aire (V ajustado) en m3 y
transfrmalos a cm3.
P||
K prom
V ajustado =
V 1=
V 2=
V 3=
V 4=
K prom
1.7992 Pa m3
1 X 1 06 c m3
=
=1.7772 X 1 05 m3 X
=17.772 c m3
3
P4
101236.1306 Pa
1m
V 5=
3
6
3
K prom
1.7992 Pa m
1 X 10 cm
=
=1.6641 X 105 m3 X
=16.641 c m 3
3
P5
108117.5408 Pa
1m
V 6=
3
6
3
K prom
1.7992 Pa m
1X 10 c m
=
=1.5449 X 1 05 m3 X
=15.449 c m3
3
P6
116454.6339 Pa
1m
V 7=
3
6
3
K prom
1.7992 Pa m
1 X 10 cm
=
=1.4371 X 105 m 3 X
=14.371 c m3
3
P7
125188.7314 Pa
1m
13.- Traza una grfica de Pabs (en el eje y) contra Vajustado (en eje x y en cm3).
60000
40000
20000
0
14
15
16
17
18
19
20
21
22
23