Professional Documents
Culture Documents
Description
Unit
Qty
Cum
480
Cum
160
Cum
50
Cum
240
Earthwork excavation in all classes of soils such as hard stiff clay, stiff black cotton,
hard red earth, shales, murram etc. except hard rock requiring blasting for
foundation and depositing within the campus with a lead of upto 100 meters in
levelled layer with all leads and lifts including cost of all labour materials equipment
and all other incidental charges like cribs, sheeting, shoring, bracing, providing
protective bunds, cofferdams, baling out water and other items which may be
necessary or convenient to the successful completion of the excavation to the
bottom of the drain removing of all logs, stumps, grubs and other deleterious matter
and obstruction including trimming bottom of excavation, cost of any cleaning
grubbing removing slips and blows if any and any surplus materials which may have
to be thrown up during the process of excavation including setting out all labour
materials, hire and fuel charges for all tools and plants, equipment, safe guards,
and incidental necessary to complete the work and subsequent removal and
cleaning the excavated materials protective bunds and cofferdams etc., as per
Standard Specification.
Beyond 3.0 Metre depth and upto 4.0 Metre depth below average ground level.
Carting out and disposing of the excess contaminated earth from the proposed site
to the assigned destination any where within the factory premises including loading,
unloading & levelling etc., complete in all respects
Forming Embankment using Brought out earth (97% Proctor Density)
Forming embankment by transporting approved soil with required lead having a
CBR value of not less than 8% and minimum Dry Density not less than 1750 Kg/cum
which has to be compacted properly and form a stable embankment including cost
and labour for proper setting out, stripping and storing the top soil, compacting the
original ground by vibratory roller of required -capacity to have a relative compaction
of required proctor density, spreading the materials uniformly over the entire width of
embankment including over section margin required for roller passing in layers of not
exceeding 200 mm compacted thickness, breaking clods, watering with all leads for
water, compacting to 97% proctor density for the soil under optimum moisture
content with moisture content adjusted in the range of one percent (1%) above and
two percent (2%) below the optimum moisture content determined as per
Rate
Both figures and in words
Amount (Rs)
IS:2720 (Part VII) with power roller/ vibrator roller rolling and using other
construction equipment approved by the engineer-in-charge and finishing the
embankment at 97% proctor density including compaction to specified requirement,
working in narrow width of embankment including hire and fuel charges for all tools
and plants and all other incidental charges etc. complete as per Standard
Specification for road embankment. (The Contractor has to make his own
arrangement for the required quantity of soil and cost and transportation of earth
including loading and unloading, etc.).
Cu.m
160
sqm
105
cum
60
Cum
70
Note : Horizontal plan area at the top of cellular raft/ raft slab level of the building will
be measured.
Providing and laying of sand filling in layers of 150mm thick including watering and
compacting all as per standard specification.
Total C/o to Summary : Rs.
B CONCRETER
Providing and laying plain cement concrete 1:4:8(one part of cement, four part of
sand and eight part of stone jelly) using 40mm size hard broken blue granite stone
1
jelly for foundation and plinth beam base all as per standard specification.
M-30 Grade :
a
cum
cum
Supplying and fixing of Precast slab for the following thickness made in
CC 1:1.5:3 (One cement, one and half fine aggregate and three coarse
aggregate) using 20mm size hard broken stone jelly including the cost of
slab, moulding, laying,finishing smooth on exposed surfaces, curing,
transportation, pointing, and also providing necessary MS angles of
3 required size based on the thickness of precast slab and to be fixed on the cum
edges of the precast slab including grouting the lugs with Cement concrete
1:1.5:3, for approach slab and other similar works but excluding the cost
of reinforcement and MS angles and as complete with all respects
complying with relevant standard specification, as directed by the EngineerIncharge.
140
75
Supply, fabricate by straightening, cutting, bending to size, place in position and tie
with 18G binding wire for steel reinforcement for all RCC works using RTS bars of
Fe 500 grade for steel reinforcements all as per standard specification
kg
39
kg
kg
kg
Cum
Cum
33
5
Providing and construction of Brick partition wall 115mm in cement mortar 1:3 (one
part of cement and three part of sand) using chamber burnt bricks of size 9x 4 x
Sqm
3 for superstructure including curing etc. as per standard specification.
15
Terrace floor
3
20
sqm
sqm
sqm
Total C/o to Summary : Rs.
250
370
350
F PLASTERING WORKS
Providing and plastering with cement mortar 1:3(one part of cement and three part
of sand), 12mm thick on the exposed surfaces of RCC members including hacking
1
the concrete surface for proper bonding etc. complete all as per standard
specification.
Providing and plastering with cement mortar 1:3 (one part of cement and three part
2 of sand), 12mm thick for the interior faces of brick wall all as per standard
specification.
Providing and plastering with cement mortar 1:4 (one part of cement and four part of
3 sand), 15mm thick for the exterior faces of brick wall all as per standard
specification.
sqm
200
sqm
215
sqm
215
Applying white washing three coats to ceilings and beams with pure shell
lime or fat lime conforming to IS-712 all as per Specification and as sqm
directed.
Providing two coats of Plastic emulsion paint to walls of approved colour
over a coat of water based primer including preparation of surface by
thorough cleaning and wetting and applying Birla putty to fill alll the
2
sqm
undulations in the plastering & as per manufacturers specification fully to
give an even shade & texture before painting and curing as per
manufacturers specifications and as directed.
Providing two coats of first quality weather proof cement paint to the
external surfaces of approved make and colour over a priming coat of
3 white colour weather proof cement paint or any primer specified by the sqm
manufacturer including preparation of surface by thorough cleaning and
wetting before painting and curing all as per manufacturer`s specifications
and as directed.(Snowcem cement paint)
1
sqm
200
215
215
35
120
120
JOINERY WORKS
Supply and fixing aluminium anodised Sliding / openable windows confirmed to
ISI specification with all fittings including supplying and fixing 6 mm thick plain glass,
accessories,fixtures all complete as per the directions of the Engineer in charge.
Sqm
33
sqm
10G (3mm) Thick 65MM Deep for Shutters up to 3.5 Mtr. wide, 75MM
Deep for Shutters exceeding 3.5 Mtr. and up to 6.00 Mtr. width and 100
mm deep for Shutters exceeding 6 Mtr. width.
BOTTOM PLATE :
For Shutters up to 2.00 Mtr. width 42mm dia OD Heavy Class pipe.
Width 2.00 Mtr. to 3.00 Mtr. -48mm OD Heavy Class pipe.
Width 3.00 Mtr. to 6.00 Mtr. -63mm OD Heavy Class pipe.
For Gear Shutters the Shaft shall consist for MS Pipe at Center and
enclosed by a cage made of 25mm or 35 wide (6mm thick) flats rings
spaced horizontally between 150 to 200 mm and tied together by 35 X
6mm flats 4 to 6 Nos. running longitudinally. Ring diameters shall be
200mm to 300mm depending on Height of Shutters.
HOOD:
The shutter roll shall be provided with a hood made of 0.90 mm thick MS
sheet reinforced on edges with 25x25x3mm angle.
FINISH:
One coat of zinc chromate primer and two coats of synthetic enamel paint
of approved color.
Each
a) for Motorised gear operated rolling shutters-RS1 (3.5m x 4.5m)
5 Providing and fixing of Hollow metal non fire rated doors as per BS 476
part-22 for stability and integrity. Pressed Galvanized steel confirming to IS
277 with the following specification. Recommended fire door shall have
doors tested and third party certified by CERTIFIRE or equivavelent, for
maximum rating of 120Mins. with vision panel. Labled doors with
certifiaction shall be with vision glass as a part of complete assembly.
Manufacturer test certificate shall cover doors both single and double leaf
and all doors supplied shall be within the tested specimen, deviation in
specification and sheet thickness other than what is mentioned in the test
certificates are not allowed. Proper label confirming the type of door and
the hourly rating is mandatory. Approved manufacturer or approved
equivalent.
Door frame shall be double rebate profile of size 143 x 57 mm made out of
1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be
Mitered and field assembled with self tabs. All provision should be
mortised, drilled and tapped for receiving appropriate hardware. Rubber
door silencers should be provided on the striking jamb. Frames should be
provided with back plate bracket and anchor fasteners for installation on a
finished plastered masonry wall opening. Once frame installed should be
grouted with cement & sand slurry 1:2 ratio necessary for fire doors on the
clear masonry opening.
15.75
Door leaf shall be 46mm thick fully flush double skin door with or without
vision lite. Door leaf shall be manufactured from 1.2mm (18guage)
minimum thick galvanised steel sheet. The internal construction of the door
should be rigid reinforcement pads for receiving appropriate hardware. The
infill material shall be resin bonded honeycomb core. All doors shall be
factory prepped for receiving appropriate hardware and provided with
necessary reinforcement for hinges, locks, and door closers. The edges
should be interlocked with a bending radius of 1.4mm. For pair of doors
astragals has to be provided on the meeting stile for both active and
inactive leaf. Vision lite wherever applicable should be of size 200x300mm
with a beeding and screws from inside. The glass should be 6mm clear
borosilicate fire rated glass of relavant rating of the door.
All doors and frames shall be finished with polyurethane aliphatic grade
paint of approved colour. The door leaf and frame shall have passed
minimum 250 hours of salt sprey test.
Rate should include supply and installation of door and hardware set as
mentioned in the door and hardware schedule.
Single leaf of size : 1200x2400mm with (200x300) vision panel with
hardware set # 1
Hardware Set 1
4 nos-CE 4330 Ball Bearing but hinge 4'' x 3'' x 3mm CE marked in SSS
1 no -Pushbar panic latch 1211, suitable for door width up to 1200mm,
Silver finish
I no -1185 WC External locking arrangement ELA with lever handle
prepared for euro profile cylinder.
one pair NMK 5542C-S 5pin EP half cyl. L=42mm one side key in SNP
(Non-master keyed)
1 no 5000 series labled door closer 5014 size 1-4 BC, with std arm in silver
5.8 mtr Self adhesive sponge seal for frames 188S, Black
sqm
cum
18
sqm
110
Finishing the top of roof slab with one course of machine pressed tiles 20cm x 20cm
x 2cm set in CM 1:3(one part of cement and three part of sand) and pointed with
1:3(one part of cement and three part of sand) mixed with water proofing compound
for weathering course all as directed by the Engineer-in-charge.
Providing and fixing PVC Down take
Supplying and fixing 50mm dia. and 150mm or more long PVC spouts in sun
shades of approved make and tint all as per specification and as directed.
RM
RM
10
5
Each
Each
Each
450x450 mm
b 600x600 mm
Total C/o to Summary : Rs.