Basic command for 2G BTS

1. For UP/DOWN StatusRLCRP: CELL=ALL ;( if shows 0 for all value site/sector will be down)
2. If site down check the condition of PCM if it is ABL (not working) verify the
loop test to identify the fault and if PCM is working check the alarm on BTS.
3. For finding the PCM use commandRXTCP: MOTY=RXOTG, CELL=cell; (cell id with sector i.e
BST001A)
It gives TG VAULE
RXAPP: MO=RXOTG-tg $; (tg$ is TG VALUE)
It gives device no. use last device
RADEP: DEV=dev$; (dev$ is device value i.e
RBLT-2719)
It gives SNT value
NTCOP: SNT=snt$;
Find the device no that is used in dev$ and corresponding vaule of DIP
4. Check the status of PCM
DTSTP: DIP=dip$; (dip$ is DIP VALUE i.e 83RBLT)
DTQDP: DIP=dip$; & DTQUP: DIP=dip$; (FOR finding error on PCM,
Check the value of es, ses uas & SLIP ,these value must be 0 or constant)
5. If PCM condition found working then BLOCK /DEBLOCK to get managed object
in working condition use command
RXBLI:MO=mo$,subord,force;
RXESE:MO=mo$,subord;
RXESI:MO=mo$,subord;
RXBLE:MO=mo$,subord;
(mo$ -RXOTG-tg$, RXOCF-tg$, RXOCON -tg$ ,RXOIS-tg$,RXOTRX-tg$-tei
value ,RXOTX-tg$-tei value,RXORX-tg$-tei value,RXOTS-tg$-tei value-time
slot no)
Page 1 of 4

6. For finding the faulty managed object use command


RXASP: MO=RXOTG-tg$;
This alarm list contains various alarms like BTS INT UNAFFECTED, BTS INT
AFFECTED, PERMANENT FAULT, some alarms can be removed by using
BLOCK/DEBLOCK commands.
7. For finding fault code on particular managed object (mo) use
RXMFP: MO=mo$;
This command shows fault code class and code some description is bellow
.
IF mo$ is RXOCF then FAULT CODE IS
2A-33 RX diversity lost2A-8 VSWR limits exceeded
2A-57 RX PATH IMBLANCE (VSWR)
2A-39 RX cable disconnected (Related faults: RXORX 1B:9 -RX cable
disconnected)
2A:7 RXDA amplifier current faults (CDU FAULTY Need replacement)
2A-21 internal power capacity reduced (PSU unit faulty or power off)
2A-41 lost communication to TRU
2A:23 Climate capacities reduced (Check fans and the Fan Control Unit)
2A:9 Power limits exceeded (Related faults: RXOTX 1B:2 TRU faulty need
replacement)
.
If mo$ is RXOTRX then fault code is
1A-13 TX saturation (TRU FAULTY Need replacement)
2A-12 TX output power limits exceeded (Related faults: TX 1B:13)
block/deblock unit if not work Change TRU2A-13 TX saturation (Related faults: TX
1B:14 -TX saturation)
block/deblock unit if not work Change TRU2A:25 TX max power restricted block /de
block unit if not work Change TRU2A:43 internal configuration fail block /debloc
k unit if not work Change TRU2A:42 Hardware IDB inconsistent check combiner chip
& then IDB
Any alarm found other than mentioned above on any manage object then pleaseconsu
lt with MSC Gorakhpur
8. FOR replacement of TRU
First get local mode on TRU by pressing Local /Remote button on TRU2nd power off
the TRU
3RD with the help of T10 Screw driver open the 2 pair screw on upper/lowerend of
unit
4th replace the faulty unit with new one
5th power on and wait until Local Lamp get constant glow
6th again get remote status by pressing Local /Remote button on TRU
Page 2 of 4

Wait for operation condition by 5minute if not operational block/deblock fromBSC


if not work contact with MSC Gorakhpur
Same processors adopt for CDU replacement (except Local/remote)
Caution must be taken for wiring of units
Tools (basic) used for hardware replacement are32
wrench
8/9 wrenchNoze pliersT10
T8
For analysis of TCH BLOCKING
1. Find that site working in full configuration by using commandRXCDP: MO=RXOTGtg$; (ALL mo must be configured)
If any BLOCKED found then use command
RXASP: MO=RXOTG-tg$; (to find the all alarm and reason of block)
IF LOCAL MODE found than try to make REMOTE otherwise
Check the fault code by commandRXMFP:MO=mo$; (to find the exact fault code to ma
ke decision thathardware if faulty or not if hardware is faulty and need replace
ment thenbook the fault to ericsson and if the hardware is not faulty theBLOCK/D
EBLOCK to make unit operational )
If any mo not block then check the half rate is on or off
For checking half rate use commandRLDHP: CELL=cell; (DHA=ON)
If DHA not ON use command to on it
RLDHC: CELL=cell, DHA=ON;
If traffic is more than for witch site is configured (as erlang B table ) then
increase the value of half rate by using commandRLDHC: CELL=cell, DTHAMR=100, DT
HNAMR=100;
Erlang B table
TRU (Per sector)
1
Traffic that supported on full rate
2.2E
2 8.0E
3 14.5E
4 21.4E
5 28.5E
6 35.8E
7 43.1E
8 50.5E
If none of the above case so new BTS is required to release congestion
Page 3 of 4

For analysis of TCH DROP/CALL DROP


1. find alarm of RXOCF i.e VSWR or RX diversity lost if present the get rectify
it
2. find alarm of TRU if any alarm the get rectified
3.
use command RLCRP:CELL=cell; and in output see the ICM band must be 1
to 3 if
ICM band is 4-5 then correspond TRU is faulty get replacement (for finding theco
rresponding TRU use BPC no. in RLCRP: CELL=cell; and RXCDP: MO=RXOTG-tg$)
4.
check handover report form Network quality report that is handover is
properly work
5. define handover if not present in neighbor list using the commandRLNRP: CELL=
cell, CELLR=all; ( for neighbor list)
RLNRI: CELL=cell, CELLR=cellr; (for cellr add in neighbor list)
Page 4 of 4