You are on page 1of 4

What is Response Spectrum in Earthquake Analysis?

We know earthquake forces shake building foundation back-forth which is finally resisted by
inertia forces produced throughout a structure. The vertical inertia forces are ignored as buildings
are usually designed for vertical static loading. Vertical forces may critical when building is
located very close to point of fault rupture.
So we will consider lateral forces here. Horizontal inertial forces depends on
-Building mass
-Ground acceleration
-Nature/type of structure

Now the ground acceleration transmitted to structure through foundation. But does full ground
acceleration is passed through foundation? Actually the both acceleration are never found same,
as building structure is not rigid i.e. the structure and its foundation are not rigid. If the rigidity
criteria is satisfied both would have same acceleration i.e. Newtons Law (F=M X A) is Valid.
Where
F=Horizontal inertia force
M=Mass of building
A=Ground acceleration.

All structures have flexibility to some extent. When a structure suffers less deformation (i.e. it
absorb some energy), the inertia force would be less than MXA (product of mass and ground
acceleration).
When a structure is very flexible (has natural period/frequency near ground waves), it would be
subjected to more force than MA under repeated ground motions.
Thus we have learnt that lateral force acting on a structure not only depend on acceleration of
ground motion but also type of building structure i.e. response of the building and foundation
too.
The relationship between structure and ground acceleration is expressed as response spectrum.
To understand response spectrum let us consider oscillators of different periods. Oscillators of
cantilever pendulums of different heights are taken which are mounted from a base that can be
shaken back-forth (cyclic motion) to simulate seismic waves recorded in previous earthquakes
(probable earthquake to be happened).
Here buildings are represented by these oscillators. For simplification single degree of freedom is
considered and various periods represent for different structural type. Under cyclic motion
maximum response Vs natural period of vibration is plotted as shown in above figure.
Maximum response under oscillation can be represented as a function of
-Acceleration
-Velocity
-Deflection
-Force action
Again every structural system contains inherently its damping mechanisms. This damping
obviously reduce large amount of response especially when repetitive motion continues.
Now we made an assumption to consider actual building as oscillator. The response curve found
in this way can be applied depending on how nearly behavior of these simple oscillators
represents complex behavior of a building.
The response spectrum is the simple way to determine maximum response under seismic ground
motion. The uniform building code provides us to use seismic co-efficient that responds nearly in
shape to response spectra produced from some/probable earthquake and also reflects the

consideration of having longer period of taller building (as taller pendulum) and shorter period
for short building. Thus shorter and stiffer building will be subjected to greater inertia forces than
taller building.

You might also like