Professional Documents
Culture Documents
Warrenton, OR
Design Basis
Amine Booster pumps will move the lean amine from the Stripper
bottoms/Expansion Drum and Lean/Rich Exchanger through a particulate
filter and Lean Amine Cooler (cooling medium: Terminal cooling water).
The Lean Amine Pumps will return the lean amine to the top of the Amine
Contactor through a flow control valve. The Pretreatment Facility will
include bulk storage of amine and a system for generating and storing demineralized water and transfer pumps to make-up for amine solution losses
in the amine regeneration system. The circulating amine fluid will also
require corrosion inhibitor, anti-foam or other chemical injection.
6.1.3
6.1.4
6.2
Oregon LNG
Warrenton, OR
Design Basis
Composition
(mol%)
Lean Gas
Heavy Gas
Estimated
Recycle
BOG, Lean
Gas
Estimated
Recycle
BOG, Rich
Gas
Carbon Dioxide
0.0050
0.0050
0.00
0.00
Nitrogen
0.6596
0.4017
13.00
8.00
Methane
96.8519
94.6765
87.00
92.00
Ethane
1.7893
3.5645
0.00
0.00
Propane
0.4519
0.9863
0.00
0.00
i-Butane
0.0681
0.1401
0.00
0.00
n-Butane
0.0927
0.0345
0.00
0.00
i-Pentane
0.0249
0.0419
0.00
0.00
n-Pentane
0.0191
0.0345
0.00
0.00
Hexane
0.0016
0.0480
0.00
0.00
Heptane
0.0008
0.0240
0.00
0.00
Octane
0.0003
0.0080
0.00
0.00
Methyl Mercaptan
0.0005
0.0005
0.00
0.00
Ethyl Mercaptan
0.0010
0.0010
0.00
0.00
Propyl Mercaptan
0.0002
0.0002
0.00
0.00
0.00
0.00
100.00
100.00
0.0331
BTX
100.00
Total
Inlet Pressure
(psia)
815
Inlet Temperature
(F)
100
0.0333
100.00
815
B
100
815
B
100
815
100
The pretreated feed gas will be delivered to the pre-cooling and liquefaction facilities
via the natural gas pipeline at 815 psia and 100F.
6.3
6.4