JIS B 8265:2010
Construction of pressure vesselGeneral principles
December, 2013
ERRATA (1/11)
Page
Position
32
Figure
11
e)
(below
the
figure)
36
6.2,
Table 2
Error
Correct
Type of
Type of
joints
joints
b) 20
Percentage
of
applying
the
radiographic examination
radiographic examination
a) 100
a) 100
c) Not
b) 20
c) Not
applied
applied
B1
1.00
0.95
0.70
B1
1.00
0.95
0.70
B2
0.90
0.85
0.65
B2
0.90
0.85
0.65
0.60
B3
0.60
B3
L1
0.55
L1
0.55
0.50
L2
0.50
0.45
L3
0.45
L2
L3
(continued)
B 8265:2010
Page
40
6.5 c)
Position
6.5 c)
ERRATA (2/11)
Error
See below.
Correct
See below.
Error: For the hub part of tube plates with hubs or flat end plates with hubs (only in the case
of machining from plates), the ultrasonic examination of the whole volume of the hub
part from the two directions, the radial and axial, of the hub shall be performed in
accordance with JIS G 0801, and the judging criteria given in 1) and 2) below shall be
satisfied.
Correct: For the hub part of tube plates with hubs or flat end plates with hubs (only in the case
of machining from plates), the ultrasonic examination of the whole volume of the hub
part from the two directions, the radial and axial, of the hub shall be performed in
accordance with JIS G 0801 before and after machining, and the judging criteria given
in 1) and 2) below shall be satisfied.
Page
60
63
Position
Table B.1 (continued)
Type: JIS G 3127
Designation: SL5N590
Base metal class
Table B.1 (continued)
Type: JIS G 3452
Designation: SGP
Fabrication method
Table B.1 (continued)
Type: JIS G 3454
Designation: STPG370
Fabrication method
Table B.1 (continued)
Type: JIS G 3454
Designation: STPG410
Fabrication method
Table B.1 (continued)
Type: JIS G 3456
Designation: STPT370
Fabrication method
Table B.1 (continued)
Type: JIS G 3456
Designation: STPT410
Fabrication method
Table B.1 (continued)
Type: JIS G 3457
Designation: STPY400
Fabrication method
Error
9B
Correct
11A
E
B
W
B
S
E
S
W
S
E
S
W
S
E
S
W
S
E
S
W
(continued)
B 8265:2010
Page
65
66
67
Position
Table B.1 (continued)
Type: JIS G 3460
Designation: STPL380
Fabrication method
Table B.1 (continued)
Type: JIS G 3461
Designation: STB340
Fabrication method
Table B.1 (continued)
Type: JIS G 3461
Designation: STB410
Fabrication method
Table B.1 (continued)
Type: JIS G 3461
Designation: STB510
Fabrication method
Table B.1 (continued)
Type: JIS G 3462
Designation: STBA12
Fabrication method
Table B.1 (continued)
Type: JIS G 3462
Designation: STBA13
Fabrication method
Table B.1 (continued)
Type: JIS G 3462
Designation: STBA20
Fabrication method
Table B.1 (continued)
Type: JIS G 3462
Designation: STBA22
Fabrication method
Table B.1 (continued)
Type: JIS G 3463
Designation: SUS329J4LTB
Fabrication method
Type: JIS G 3463
Designation: SUS329J4LTB
Add the values in the right as
the allowable tensile stress
values for fabrication method
W
(added
above),
for
temperatures 40 C, 75 C,
100 C, 125 C, 150 C,
175 C, 200 C, 225 C,
250 C, 275 C and 300 C,
respectively.
ERRATA (3/11)
Error
S
E
Correct
S
W
S, E
E
S, W
W
S, E
E
S, W
W
S, E
E
S, W
W
S, E
E
S, W
W
S, E
E
S, W
W
S, E
E
S, W
W
S, E
E
S, W
W
S
W
(continued)
B 8265:2010
Page
68
77
Position
Table B.1 (continued)
Type: JIS G 3464
Designation: STBL380
Fabrication method
Table B.1 (continued)
NOTE 3
80
83
ERRATA (4/11)
Error
S, E
E
S : seamless pipes; E :
electric resistance welded
tubes; A : submerged arc
welding
tubes;
W
:
automatic arc welding tubes
or electric resistance welded
tubes.
The external pressure chart
number in this row may be
applied to JIS G 4051, JIS G
4303, and JIS G 4311, only
when used for stiffening
rings
205 [Outer diameter 4 mm
or over up to and incl.
100 mm
/Wall thickness 0.3 mm
or over up to and incl.
30 mm]
205 [Outer diameter 4 mm
or over up to and incl.
250 mm
/Wall thickness 0.3 mm
or over up to and incl.
30 mm]
205 [Outer diameter 4 mm
or over up to and incl.
250 mm
/Wall thickness 0.3 mm
or over up to and incl.
30 mm]
205 [Outer diameter 4 mm
or over up to and incl.
100 mm
/Wall thickness 0.3 mm
or over up to and incl.
30 mm]
Correct
S,W
W
S: seamless pipes ; B:
forge-welded tubes ; W :
electric resistance welded
tubes;
submerged
arc
welding tubes; automatic arc
welding tubes or laser
welding tubes.
The external pressure chart
number in this row may be
applied only when used for
stiffening rings
(continued)
B 8265:2010
Page
83
ERRATA (5/11)
Position
Table B.3 (continued)
Type: JIS H 3300
Model: 1201
Quality class: OL
Specified minimum tensile
strength
Table B.3 (continued)
Type: JIS H 3300
Model: 1220
Quality class: OL
Specified minimum tensile
strength
Error
205 [Outer diameter 4 mm
or over up to and incl.
250 mm
/Wall thickness 0.3 mm
or over up to and incl.
30 mm]
205 [Outer diameter 4 mm
or over up to and incl.
250 mm
/Wall thickness 0.3 mm
or over up to and incl.
30 mm]
Correct
205 [Outer diameter 4 mm
or over up to and incl.
250 mm
/Wall thickness 0.25
mm or over up to and
incl. 30 mm]
205 [Outer diameter 4 mm
or over up to and incl.
250 mm
/Wall thickness 0.25
mm or over up to and
incl. 30 mm]
B 8265:2010
Page
83
84
Position
Table B.3 (continued)
Type: JIS H 3300
Model: 1862
Quality class: 1/2H
Specified minimum tensile
strength
Table B.3 (continued)
Type: JIS H 3300
Model: 5010
Quality class: 1/2H
Designation
(at two positions: one in the
fourth column from the left,
the other in the rightmost
column)
Table B.3 (continued)
Type: JIS H 3300
Model: 5010
Quality class: 1/2H
Specified minimum tensile
strength
Table B.3 (continued)
Type: JIS H 3300
Model: 1565
Quality class: 3/4H
Specified minimum tensile
strength
Table B.3 (continued)
Type: JIS H 3300
Model: 1862
Quality class: 3/4H
Designation
(at two positions: one in the
fourth column from the left,
the other in the rightmost
column)
Table B.3 (continued)
Type: JIS H 3300
Model: 1862
Quality class: 3/4H
Specified minimum tensile
strength
ERRATA (6/11)
Error
305 [Outer diameter 4 mm
or over up to and incl.
250 mm
/Wall thickness 0.15
mm or over up to and
incl. 30 mm]
C5010T-1/2H
C5010T-1/2H
Correct
305 [Outer diameter 4 mm
or over up to and incl.
250 mm
/Wall thickness 0.15
mm or over up to and
incl. 25 mm]
C5010T-1/2H
C5010TS-1/2H
(continued)
B 8265:2010
Page
84
Position
Table B.3 (continued)
Type: JIS H 3300
Model: 5010
Quality class: 3/4H
Designation
(at two positions: one in the
fourth column from the left,
the other in the rightmost
column)
Table B.3 (continued)
Type: JIS H 3300
Model: 5010
Quality class: 3/4H
Specified minimum tensile
strength
Table B.3 (continued)
Type: JIS H 3300
Model: 1020
Quality class: H
Specified minimum tensile
strength
ERRATA (7/11)
Error
C5010T-3/4H
C5010T-3/4H
Correct
C5010T-3/4H
C5010TS-3/4H
(continued)
B 8265:2010
Page
84
Position
Table B.3 (continued)
Type: JIS H 3300
Model: 1565
Quality class: H
Specified minimum tensile
strength
ERRATA (8/11)
Error
400 [Outer diameter 51 mm
or under
/Wall thickness 0.15
mm or over up to and
incl. 4 mm]
C1862T-H
C1862T-H
C5010T-H
C5010T-H
Correct
400 [Outer diameter 25 mm
or under
/Wall thickness 0.15
mm or over up to and
incl. 3 mm]
400 [Outer diameter over 25
mm up to and incl. 51
mm
/Wall thickness 0.15
mm or over up to and
incl. 4 mm]
C1862T-H
C1862TS-H
(continued)
B 8265:2010
Page
84
102
Position
Table B.3 (continued)
Type: JIS H 3300
Model: 5010
Quality class: H
Specified minimum tensile
strength
199
Table B.4
Type: JIS G 4107
Model dimensions
Table C.14 (concluded)
Standard
composition:
55Ni-21Cr-13.5Mo
Grade symbol
Table D.1 (continued)
Type of materials: Titanium
alloy Type 61
Longitudinal
elastic
coefficient of materials at
each temperature, 20
F.9
216
Figure G.2 b) 4)
112
115
Error
ERRATA (9/11)
Error
400 [Outer diameter 51 mm
or under
/Wall thickness 0.15
mm or over up to and
incl. 4 mm]
Type 3 < 63
Correct
400 [Outer diameter 25 mm
or under
/Wall thickness 0.15
mm or over up to and
incl. 3 mm]
400 [Outer diameter over 25
mm up to and incl. 51
mm
/Wall thickness 0.15
mm or over up to and
incl. 4 mm]
Type 3 63
N06002
N06022
101
110
1.5g0 min.
1.5g0 min.
Taper 1/3 or under
Weld centre
: Corrected position
(continued)
B 8265:2010
Page
250
Position
Figure I.2 a) 3)
ERRATA (10/11)
Error
min.
max.
min.
max.
Page
253
Position
Figure I.4
: Corrected position
Error
Metal
to
metal contact
Flange II
Flange I
Flange I
Flange II
Page
267
Position
L.3.2
273
M.1
min.
: Corrected position
Error
The calculated thickness of
the bolted flat cover plate
shall be as given in a) to c)
below.
This Annex applies to the
calculation of plates of
pressure vessels.
Correct
The calculated thickness of
the bolted flat cover plate
shall be as given in a) to d).
This Annex applies to the
calculated thickness of plates
of pressure vessels.
(continued)
B 8265:2010
Page
274
Position
Figure M.1 b)
Error
ERRATA (11/11)
Page
277
Position
M.5 c)
M.6
284
Figure O.2
Below b)
Error
The load by which.the total area
occupied by the tube hole from the
area supported by the tube
stay,..
a: allowable tensile stress of the
material..However, in the
case of stays that are fixed by
welding, it shall be the
allowable tensile stress of the
material of the stay.
Meanings of symbols used in the
figures:
: Corrected position
Correct
The load by which.the total area
occupied by the tube hole and the area
occupied by the stay tube from the area
supported by the tube stay,..
a: allowable tensile stress of the
material..However, in the case of
stays having welds, it shall be the
allowable tensile stress of the
material of the stay.
Meanings of symbols used in the
figures:
(concluded)