You are on page 1of 90

Tecnoclima

Energy & Comfort


from the Air

Tecnoclima SpA, founded by Alfonso Vescovi in 1973 is located in Pergine


Valsugana Italy. It manufactures equipment for hot-blast heating, ventilation,
air-drying and heat recovery, as well as units for air treatment and air
conditioning.
Over 300 models of top-quality equipment have been designed and
manufactured for heating and conditioning in various application fields:
factories, small business, civil, agricultural, poultry halls, churches, residential
emergency, rental as well as bespoke equipment for special uses.
2

THE PRODUCT RANGE


Warm
Warm air
air heaters
heaters (heating
(heating only)
only)

DRY
DRY
Technology
Technology

Air
only
Air handling
handling units
units heating
heating only
only
(heating,
only (heating,
ventilation,
ventilation, filtration)
filtration)
RoofRoof
Rooftops (heating,
(heating, ventilation,
ventilation, cooling,
cooling,
Roof--tops
dehumidification
dehumidification and
and filtration)
filtration)
Cross-flow
recuperators
Cross-flow heat
heat recuperators,
recuperators,
destratifiers.
recuperators,, destratifiers.

WET
WET
Technology
Technology

Water-coil
Water-coil air
air heater,
heater, modular
modular air
air handling
handling unit
unit

Chiller
Chiller and
and air-water
air-water heat
heat pumps
pumps

300
300
MODELS
MODELS

THE PRODUCT RANGE


HEATING
INDUSTRIAL, COMMERCIAL e RESIDENTIAL sector

DRY Technology
Blown air burner

T e c hno lo g y
H e a t (k W )
Co o l (k W )
3

A ir (m 3 / h)
Ins ta lla tio n

TC

TE

BA

HB

DM

DR Y

DR Y

DR Y

DR Y

DR Y

601160
60 1160

47391
47 391

34105
34 105

2241
22 41

1834
18 34

4 3 0 0 7 0 0 0 0

2 8 0 0 2 3 0 0 0

19 0 0 6 3 0 0

14 0 0 2 8 5 0

8 5 0 16 0 0

I/ E

THE PRODUCT RANGE


HEATING
INDUSTRIAL and COMMERCIAL sector

DRY Technology
Blown air burner

Technology
Heat (kW)
Cool (kW)
3

Air (m /h)
Installation

ENERGY

UTAK

SR

DUOMO

WIMBLEDON

DRY

DRY

DRY

DRY

DRY

60
60 1070

120
120 760

190
190 1000

150
150 870

150
150 400

460071000

830053000

760067000

1400080500

1400080500

I/ E

I/ E

THE PRODUCT RANGE


HEATING
INDUSTRIAL, COMMERCIAL e RESIDENTIAL sector

DRY Technology
Atmospheric burner

Technology
Heat (kW)
Cool (kW)
3

Air (m /h)

MJ

PA

UT/UTK

DRY

DRY

DRY

17
17 37

15
15 105

15
15 105

16303450

12508750

12508750

THE PRODUCT RANGE


HEATING
INDUSTRIAL, COMMERCIAL e RESIDENTIAL sector

DRY Technology
Atmospheric burner

PCM

Technology
Heat (kW)
Cool (kW)
3

Air (m /h)
Installation

DRY
24 94
1.400 9.000

CONDENSING
suspended
gas-fired
heater with
syncronized flame
and air-flow
modulation

THE PRODUCT RANGE


HEATING
AGRICOLTURE, POULTRY, BREEDING and MOBILE sector

DRY Technology

AGRI-P

Technology
Heat (kW)
Cool (kW)
3

Air (m3/h)
Installation

AGRI-C S.CIKKI 80 MB-UNIT

DRY

DRY

DRY

DRY

40
40 186

40
40 186

80

40
40 186

410013800

410013800

2000

350013500

I/ E

I/ E

THE PRODUCT RANGE


HEATING & CONDITIONING
INDUSTRIAL, COMMERCIAL e RESIDENTIAL sector

DRY Technology

CF-GAS KLIMAXs

Technology
Heat (kW)
Cool (kW)
3

Air (m3/h)
Installation

BOXY

RCF

RCU

DRY

DRY

DRY

DRY

DRY

30
30 191

21
21 53

50200

24
24 171

19
19 52

50200

350026000

390010400

860033600

350012600

2903150

I/ E

I/ E

I/ E

I/ E

THE PRODUCT RANGE


Air mixing units

DST Destratifiers

DST 35

Nm3/h 3.500

DST 85

Nm3/h 8.500

Available with or without thermostat

THE PRODUCT RANGE


HEATING & CONDITIONING
INDUSTRIAL, COMMERCIAL e RESIDENTIAL sector

WET Technology

T e c hno lo g y
H e a t (k W )
Co o l (k W )
A ir (m 3 / h)
Ins ta lla tio n

TANDEM

NTN

NTPM

AZN

KUBO

W ET

W ET

W ET

W ET

W ET

32

29283
29 283

13115
13 115

3 17
17

11200
11

1 0 46
521
21

8 22
22

1 9
9

3950

2 0 0 0 2 0 0 0 0

9 0 0 4 2 0 0

17 5 0 10 9 0 0

2 4 0 13 5 0

I/ E

THE PRODUCT RANGE


HEATING & CONDITIONING
INDUSTRIAL, COMMERCIAL e RESIDENTIAL sector

WET Technology
Chiller and waterwater-air heat pumps

SUPERBESST SUPERFRESH

Technology
Heat (kW)
Cool (kW)
Installation

WET

WET

637

637

637

TECHNOLOGY

AIR HEATING WITH


DIRECT HEAT EXCHANGE
EXCHANGE

THE DRY SYSTEM

TECHNOLOGY THE DRY SYSTEM


PHENOMENOLOGY

In the DRY SYSTEM the heat


developed by the combustion is
transmitted, through the heat
exchanger, DIRECTLY to the AIR,
without any intermediary thermal
carrier (water and/or steam)

TECHNOLOGY THE DRY SYSTEM


PHENOMENOLOGY
Heat
(flame & fumes)
Air flow
Heat
exchanger
Fan

FORCED convection

THE TECHNOLOGY THE DRY SYSTEM


STRENGHTS OF THE DRY SYSTEM

CHARACTERISTS

ADVANTAGES

 Little thermal inertia

 Fast achievement of the set


temperature level, ideal in case of
intermittent or occasional operation

 Functioning only in the periods of


use of the spaces

 Fuel saving

 High thermal efficiencies: from 90%


for the traditional products up to
108% for the more sophisticated
condensing appliances

 Definitely reduced fuel consumption

 Absence of intermediary fluids


(water of steam)

 Maximal distribution efficiency


 No problems with frost

 Controllable supply air temperature

 Reduced air stratification

THE TECHNOLOGY THE DRY SYSTEM


STRENGHTS OF THE DRY SYSTEM

CHARACTERISTICS

ADVANTAGES

 Possible filtering section


 Fresh air rate from 0% up to 100%
for air renewal when necessary
 Also only summer ventilation

 Air handling system (ventilation and


filtration) assuring rapidly a good
comfort level

 Packaged (single block)


autonomous units
 Installation in- or outside of the
heated rooms

 No need of thermal central neither of


hydraulic works
 Easy to modify and move the heating
plants in case of enlargements,
restructuring or move

 Little installation and operation costs

FLOORFLOOR-STANDING

WARM AIR HEATERS

FLOOR-STANDING WARM AIR HEATERS


PRINCIPLE OF OPERATION

FLOOR-STANDING WARM AIR HEATERS


APPLICATIONS

Installation: INDOOR / OUTDOOR


Configuration: VERTICAL / HORIZONTAL
Air diffusion: DIRECT / VIA AIR DUCTS
Operation: RECYCLED / FRESH AIR

FLOOR-STANDING WARM AIR HEATERS


TCTC-E SERIES
For
For indoor
indoor installations
installations and
and direct
direct air
air diffusion
diffusion
Power Input
from 60 to 1160 kW

FLOOR-STANDING WARM AIR HEATERS


TCTC-E SERIES
For
For indoor
indoor installations
installations and
and diffusion
diffusion via
via air
air ducts
ducts
Power Input
from 60 to 1160 kW

FLOOR-STANDING WARM AIR HEATERS


APPLICATION EXAMPLES

FLOOR-STANDING WARM AIR HEATERS


TCOTCO-E SERIES
For
For indoor
indoor installations
installations and
and diffusion
diffusion via
via air
air ducts
ducts
Power Input
from 60 to 1160 kW

FLOOR-STANDING WARM AIR HEATERS


APPLICATION EXAMPLES

FLOOR-STANDING WARM AIR HEATERS


APPLICATION EXAMPLES

FLOOR-STANDING WARM AIR HEATERS


TCTC-E/K HEATER FOR EXTERNAL INSTALLATION

FLOOR-STANDING WARM AIR HEATERS


APPLICATION EXAMPLES

FLOOR-STANDING WARM AIR HEATERS


TCTC-SP SPECIAL SERIES

Low
Low temperatures
temperatures

Outdoor
Outdoor temperature
temperature down
down to
to -55C
-55C
Operation
Operation with
with 100%
100% fresh
fresh air
air

High-thickness
High-thickness panel
panel insulation
insulation
Insulated
box
Insulated burner
burner box,
box,
with ventilated
ventilated and
and controlled
controlled electric
electric heater,
heater,
box with
combustion
air
inlet
and
terminals
for
the
connection
of
the
electric
combustion air inlet and terminals for the connection of the electric
board,
board, to
to be
be installed
installed in
in remote
remote position
position in
in the
the heated
heated rooms
rooms
Electrical
pre
Electrical motors
motors with
with prepreheated windings
windings
pre--heated
Special
Special fans
fans with
with bearings
bearings suitable
suitable for
for low
low temperatures
temperatures
Special
Special electrical
electrical components
components (cables,
(cables, thermostats,
thermostats, etc.)
etc.)

FLOOR-STANDING WARM AIR HEATERS


TCTC-SP SERIES for PROCESSES

Industrial
Industrial processes
processes
(high
(high temperature)
temperature)

Painting
Painting
Drying
Drying
Polymerization
Polymerization
Various
Various treatments
treatments at
at high
high temperature
temperature

Hygienization
Hygienization processes
processes
Toasting
Toasting // Roasting
Roasting

FLOOR-STANDING WARM AIR HEATERS


TCTC-SP SERIES for PROCESSES

FLOOR-STANDING WARM AIR HEATERS


TE SERIES
For
For indoor
indoor installations
installations and
and direct
direct air
air diffusion
diffusion
Power Input
from 40 to 350 kW

FLOOR-STANDING WARM AIR HEATERS


BABA-S SERIES
For
For indoor
indoor installations
installations and
and direct
direct air
air diffusion
diffusion
Power Input
from 34 to 105 kW

FLOOR-STANDING WARM AIR HEATERS


NEW PRODUCTS

HIGH EFFICIENCY

FLOOR-STANDING WARM AIR HEATERS


DUOMO SERIES TOTALLY CONDENSING
Already
Already condensing
condensing at
at the
the maximal
maximal power
power !!
Input Power
from 152 to 874 kW

Comb.
30
Comb. efficiency
efficiency from
from 97
97 up
up to
to 108%
108% with
with fumes
fumes at
at 30
30
C
30C
Modulating
Modulating burner
burner
Heat
sections
Heat exchanger
exchanger arranged
arranged in
in 22 parallel
parallel sections,
sections,
sections each
each
invested
invested by
by 22 independent
independent air
air flows
flows
Air
Air and
and fumes
fumes heat
heat exchange
exchange in
in against
against current
current
Oversized
Oversized plate
plate heat
heat exchanger
exchanger built
built in
in stainless
stainless steel
steel AISI
AISI
304
and
provided
with
condensate
drain
pipe
304 and provided with condensate drain pipe
Temperature
15
Temperature increase
increase limited
limited between
between 30
30 and
and 15
15
C
15C
Patented
Patented

FLOOR-STANDING WARM AIR HEATERS


DUOMO SERIES TOTALLY CONDENSING

FLOOR-STANDING WARM AIR HEATERS


ENERGY SERIES CONDENSING
For
For indoor
indoor or
or outdoor
outdoor installations
installations and
and direct
direct or
or ducted
ducted air
air diffusion
diffusion
Input Power
from 66 to 711 kW
Modulating
two
Modulating or
or twotwostages gas
gas burner
burner
two--stages
Plate
Plate heat
heat exchanger
exchanger in
in stainless
stainless steel
steel AISI
AISI 304
304 and
and
condensate
condensate drain
drain pipe
pipe
Condensing
Condensing at
at the
the partial
partial load
load
Combustion
Combustion efficiency
efficiency at
at reduced
reduced power
power 102%
102%

Little
Little T,
T, minimal
minimal stratification
stratification

Supply
Supply temperature
temperature controlled
controlled

More
More continuous
continuous operation
operation

High
High average
average seasonal
seasonal efficiency
efficiency

FLOOR-STANDING WARM AIR HEATERS


ENERGY SERIES CONDENSING

SOME INSTALLATIONS
TC 300 E FOR DIRECT AIR DIFFUSION

SOME INSTALLATIONS
TC 375 EKEK-SP OUTSIDE INSTALLATION

SOME INSTALLATIONS
TC 200 EK DOWNFLOW

installed in a sport hall

SOME INSTALLATIONS
WARM AIR HEATER MODEL TCO 200 E

SPORT FACILITIES
COMPLETE SYSTEMS FOR PRESSOSTATIC STRUCTURES

GREENHOUSE TOMATOES MEXICO


WARM AIR HEATERS model TCO 300 SP

44

CHICKEN POULTRY EGYPT


WARM AIR HEATERS

Location

Desert zone near Il Cairo (Egypt)

Application

Installation for the heating of 222


warehouses for the production of
38.000.000 chicken/year, on a
covered area of 37 ha. By night the
temperature decreases until 0

Equipments

N. 550 air heaters in particular


N. 450 TC175E-SP ( 200 kW/cad.)

45

FLOOR-STANDING WARM AIR HEATERS


UTAK SERIES CONDENSING
For
(roof
only
For horizontal
horizontal outdoor
outdoor installations
installations (roof(rooftop heating
heating only
only
(roof--top
only))
Input Power
from 121 to 758 kW

Designed
Designed for
for outdoor
outdoor installation
installation on
on the
the roof
roof
Low
Low temperature
temperature versions
versions available
available also
also with
with internal
internal
recirculation
recirculation
Special
Special fan
fan with
with high
high aeraulic
aeraulic performaces
performaces
(standard
version
500
Pa,
S
version
Pa
Pa
(standard version 500 Pa,
up to
to 800
800 Pa)
Pa)
Pa S version up
Pa
Modulating
two
Modulating or
or twotwostages burner
burner
two--stages
Plate
Plate heat
heat exchanger
exchanger in
in stainless
stainless steel
steel AISI
AISI 304
304 and
and
condensate
drain
pipe
condensate drain pipe
Condensing
Condensing at
at the
the partial
partial load
load
Combustion
Combustion efficiency
efficiency at
at reduced
reduced power
power 102%
102%

SOME INSTALLATIONS
Condensing modular air treatment RoofRoof-top UTAK 600

FLOOR-STANDING WARM AIR HEATERS


UTAK SERIES CONDENSING

FLOOR-STANDING WARM AIR HEATERS


SR SERIES CONDENSING HEATING SECTIONS
For
For aeraulic
aeraulic installations
installations already
already provided
provided with
with their
their own
own ventilation
ventilation system
system
Power Input
up to 1000 kW

Installable
Installable after
after or
or before
before the
the fan
fan and
and working
working respectively
respectively
under
positive
or
negative
pressure
under positive or negative pressure

Heat
Heat exchanger
exchanger with
with plate
plate fumes
fumes pipes
pipes in
in stainless
stainless steel
steel
304
with
condensate
drain
pipe,
suitable
for
coupling
AISI
AISI 304 with condensate drain pipe, suitable for coupling
with
with modulating
modulating burners
burners and
and condensing
condensing functioning
functioning and
and
treatment
of
low
temperature
air
treatment of low temperature air

Supplied
Supplied complete
complete with
with safety
safety thermostats
thermostats
and
flow
and flowflowswitches
flow--switches

FLOOR-STANDING WARM AIR HEATERS


SR SERIES CONDENSING HEATING SECTIONS

Special equipment supplied to AIR FORCE


AIRMOBILE TREATMENT AIR UNITS

SUSPENDED
WARM AIR HEATERS

SEALED CHAMBER SUSPENDED AIR HEATERS


PRINCIPLE OF OPERATION

SEALED CHAMBER SUSPENDED AIR HEATERS


PRINCIPLE OF OPERATION

SEALED CHAMBER SUSPENDED AIR HEATERS


APPLICATIONS

Installation: INDOOR / OUTDOOR


Air diffusion: DIRECT / DUCTED

SEALED CHAMBER SUSPENDED AIR HEATERS


PAPA-MINIJET SERIES
For
For INDOOR
INDOOR installations
installations
PA series from 15 to 105 kW

Minijet series from 17 to 37 kW

SEALED CHAMBER SUSPENDED AIR HEATERS


APPLICATION EXAMPLES

SEALED CHAMBER SUSPENDED AIR HEATERS


APPLICATION EXAMPLES

SEALED CHAMBER SUSPENDED AIR HEATERS


PA SERIES
SingleSingle
two
two
Singlestage, twotwostages or
or twotwopower levels
levels
Single--stage,
two--stages
two--power

MODELLO

Portata
termica

Potenza termica Potenza termica Portata aria max Portata aria min
utile max
utile min (*)
a +20
20
a +20
20 (**)

Tensione
elettrica

kW

kW

kW

m3/h

m3/h

PA 16

15,0

13,8

8,7

1.250

1.000

230

PA 26

25,4

23,0

15,8

1.820

1.750

230

PA 36

33,8

30,5

21,0

2.920

2.600

230

PA 46

46,3

41,7

28,8

4.130

3.700

230

PA 66

65,0

58,6

40,5

5.900

5.000

230

PA 86

85,0

76,6

52,9

7.900

7.200

230

PA 106

104,7

94,3

65,2

8.750

7.800

230

(*) versioni bistadio e bipotenza


(**) versioni bipotenza

SEALED CHAMBER SUSPENDED AIR HEATERS


MJ SERIES
SingleSingle
two
Singlestage or
or twotwostages
Single--stage
two--stages

MODELLO

Portata
termica

Potenza termica Potenza termica Portata aria max Portata aria min
utile max
utile min (*)
a +20
20
a +20
20 (*)

Tensione
elettrica

kW

kW

kW

m3/h

m3/h

MJ 20

17,3

16,0

10,9

1.630

1.290

230

MJ 30

27,2

25,0

17,2

2.550

2.040

230

MJ 40

36,7

34,0

22,9

3.450

2.710

230

(*) versioni bipotenza

SEALED CHAMBER SUSPENDED AIR HEATERS


UT SERIES
For
For INDOOR
INDOOR installations
installations

Input power from 25 to 105 kW

SEALED CHAMBER SUSPENDED AIR HEATERS


APPLICATION EXAMPLES

SEALED CHAMBER SUSPENDED AIR HEATERS


UTK SERIES
For
For OUTDOOR
OUTDOOR installations
installations

Input power from 25 to 105 kW

SEALED CHAMBER SUSPENDED AIR HEATERS


APPLICATION EXAMPLES

SEALED CHAMBER SUSPENDED AIR HEATERS


APPLICATION EXAMPLES

SOME INSTALLATIONS
UTK installed in large warehouses

SEALED CHAMBER SUSPENDED AIR HEATERS


APPLICATION EXAMPLES

SEALED CHAMBER SUSPENDED AIR HEATERS


APPLICATION EXAMPLES

SEALED CHAMBER SUSPENDED AIR HEATERS


APPLICATION EXAMPLES

SEALED CHAMBER SUSPENDED AIR HEATERS


APPLICATION EXAMPLES

PACKAGED AUTONOMUOS
AIR HANDLING UNITS

ROOF - TOP

PACKAGED AUTONOMOUS ROOF-TOP UNITS


CONTRUCTION SCHEME
Condensing fans

Evaporating battery (summer cycle)

Filtering section
Scroll
compressors

Condensing
batteries

Centrifugal fan
Gas burner
Gas heat exchangers (heating cycle)

PACKAGED AUTONOMOUS ROOF-TOP UNITS


PRINCIPLE OF OPERATION

WINTER
CYCLE

PACKAGED AUTONOMOUS ROOF-TOP UNITS


PRINCIPLE OF OPERATION

SUMMER
CYCLE

PACKAGED AUTONOMOUS ROOF-TOP UNITS


MAIN CHARACTERISTICS
Heat output from 30 kW to 191 kW
Cooling output from 24 kW to 171 kW
Air rate from 3.500 to 26.000 m3/h

PACKAGED AUTONOMOUS ROOF-TOP UNITS


APPLICATION EXAMPLES

PACKAGED AUTONOMOUS ROOF-TOP UNITS


APPLICATION EXAMPLES

PACKAGED AUTONOMOUS ROOF-TOP UNITS


APPLICATION EXAMPLES

PACKAGED AUTONOMOUS ROOF-TOP UNITS


APPLICATION EXAMPLES

PACKAGED AUTONOMOUS ROOF-TOP UNITS


APPLICATION EXAMPLES

PACKAGED AUTONOMOUS ROOF-TOP UNITS


APPLICATION EXAMPLES

PACKAGED AUTONOMOUS ROOF-TOP UNITS


MIXING MODULE WITH 3 DAMPERS AND RECYCLE/EXHAUST FAN

0100%

0100%

100%

PACKAGED AUTONOMOUS ROOF-TOP UNITS


CFCF-GAS SERIES

Inp ut
p o we r c a p a c ity

Outp ut
p o we r c a p a c ity

Co o ling
p o we r c a p a c ity

A ir flo w ra te
a t +20

S ta nd rd
e xte rna l s ta tic
p re s s ure

P o we r s up p ly

kW

kW

kW

m3/ h

Pa

CF 100 GA S

33,8

30,5

23,8

3.500

250

230/400

CF 200 GA S

59,2

53,5

35,5

5.800

250

230/400

CF 300 GA S

71,7

64,7

47,6

7.400

250

230/400

CF 400 GA S

98,8

89,1

64,5

9.700

250

230/400

CF 500 GA S

130,0

117,2

92,2

12.600

250

230/400

CF 600 GA S

170,0

153,2

137,0

18.500

250

230/400

CF 700 GA S

209,4

190,6

170,6

23.000

250

230/400

MOD E L

SOME OTHER INSTALLATIONS


RoofRoof-top CF 300 GAS installed in a car shop building

SIEMENS FACTORY - GERMANY


AUTONOMOUS SINGLESINGLE-PACKAGE AIR TREATMENT UNITS

WHIRLPOOL FACTORY
AIR TREATMENT UNITS FOR HEATING AND AIR VENTILATION

SOME INSTALLATIONS
RoofRoof-top CF 500 GAS installed in a gymnasium

Ferrari factory Italy


RoofRoof- top special CF GASGAS-SP

The Applications

COMMERCIAL CENTRE
KLIMAXs AUTONOMOUS SINGLE-PACKAGE AIR TREATMENT UNITS

89

You might also like