Professional Documents
Culture Documents
Changes
Date
3.0
June 2015
1. Short Definition
Licensing of adapters for SAP NetWeaver Exchange Infrastructure (SAP NetWeaver XI) 3.00 / SAP
NetWeaver Process Integration (SAP NetWeaver PI) 7.00 or higher release can be licensed based on the
request volume in gigabytes (GB) per month processed by the particular adapter. The size of the payload is
determined in the integration server. Afterwards, the sender and receiver systems are aggregated and
divided into the individual adapter types.
2. Description of Metric
The request size is determined by the payload size of each request that is successfully processed by the
integration server (IS) and, in synchronous cases, the size of the response. This also includes the
attachments. Mapping steps can cause the request size to vary significantly during the processing of the
message in the integration server.
That is why four measurements are made while processing the message:
(Pl_Req)
(Pl_Req_Map)
(Pl_Resp)
(Pl_Resp_Map)
The result of the calculation in bytes is stored in raw data tables. The raw data is then aggregated according
to
Sender system
Receiver system
Processing mode (synchronous/asynchronous)
The aggregates are then stored in separate tables. The aggregation takes place at different steps, on an
hourly, daily, and monthly basis.
3. Definition of objects
The request size processed using a particular adapter is determined by the payload size of an XI/PI request
in the integration server at the time of the measurement. The size of the request is measured four times
while the request is processed in the integration server, see Error! Reference source not found. Error!
Reference source not found.. The measured values are stored in the XI/PI message object. After the
request has been successfully sent using the aforementioned metric, the measured values are combined to
give the total value of the payload size. These values are then saved specifically for each adapter and used
for the system measurement.
The measured payload for XI/PI Adapters will be calculated in Megabyte (MB)
-1-
4. Notes on Measurement
The following adapters are relevant for measurement:
ID
Unit
Measurement*
2608
Relevant
2611
Relevant
2613
Relevant
2630
Relevant
2631
Relevant
2632
Relevant
2633
Relevant
2634
Relevant
2637
Relevant
2639
Relevant
2647
Seeburger AS2
Relevant
2648
Seeburger OFTP
Relevant
2649
Relevant
2650
Relevant
2651
Relevant
2652
Relevant
2653
Seeburger Automotive
Relevant
2654
Seeburger Chemicals
Relevant
2655
Relevant
2657
Seeburger High-Tech
Relevant
2658
Seeburger Paper
Relevant
-2-
2659
Seeburger Pharmaceutical
Relevant
2660
Seeburger Retail
Relevant
The following adapters are relevant for measurement. However, the price-relevant metric is not the given
data volume. This serves as an indication only. If a measured value is greater than 0, these adapters are
considered to be in active use.
ID
Unit
Measurement*
2616
Indicator
2619
Indicator
2620
Indicator
2625
Indicator
2626
Indicator
2627
Indicator
2628
Indicator
2640
Indicator
2641
Indicator
2643
Indicator
2644
Indicator
The following adapters are included in the standard and are not relevant for measurement.
ID
Unit
Measurement*
2600
Unclear status
Not relevant
2601
Not relevant
2602
Not relevant
-3-
2603
Not relevant
2604
Not relevant
2605
Not relevant
2606
Not relevant
2607
Not relevant
2609
Not relevant
2610
Not relevant
2612
Not relevant
The following adapters are not part of the standard price list. If one of these adapters was measured, the
relevance of the result must be examined in that particular case.
ID
Unit
Measurement*
2614
Indicator
2615
Indicator
2617
Indicator
2618
Indicator
2621
iWay Adapter i2
Indicator
2622
Indicator
2623
Indicator
2624
Indicator
2629
Indicator
2635
Indicator
2636
Indicator
2638
Indicator
-4-
2642
Indicator
2645
Indicator
2646
Indicator
2656
Indicator
2661
Indicator
2662
Seeburger PapiNet
Indicator
The PI/XI-Base Engine will be measured via Unit IDs 2320 - 2323.
If the measurement log does not list all adapters used, please implement note 1648864.
5. Information on Measurement Availability
Measurement results are only displayed in the log if both the software component SAP_BASIS and the
application are at the required Support Package (SP) level.
The adapters can only be measured with SAP NetWeaver XI 3.0 or later. For technical reasons, earlier
releases cannot be measured.
Component
Shipment
with Note
6.40
SP 18
7.00
SP 09
-5-