You are on page 1of 3

FW 740/750

RESET E# 2 --> E# 8
Vao SP# 38 --> thay oi Data 1 --> 0 .

SERVICE CALL CONDITION


SC Code E-1: Exposure Lamp Abnormal
-DefinitionThe light sensor voltage is less than 0.4 volts for 10 seconds.
<Points to check>
+ Exposure lamp . + Light sensor .
+ FL regulator (CN402-1,2,4, and 5, CN401-1, -2, -4)
+ Main board (CN106-A3, and CN104-B1, -B2, -A29 -A30)

SC Code E-2: Fusing Thermofuse Open


-DefinitionThe temperature detected by the hot roller thermistor does not reach 100 C
within 4 minutes and 30 seconds after the main switch is turned on.
<Point to check>
+ Fusing thermofuse . + Hot roller thermistor
+ AC drive board (T202-2, RA201-T4) .
+ Main board (CN106-A2, A4, B12, B14, B15)

SC Code E-3: Hot Roller Thermistor Open


-DefinitionThe temperature detected by the hot roller thermistor does not reach 50C
within 3 minutes after the main switch is turned on.
<Point to check>
+ Hot roller thermistor . + AC drive board ( T202-2, RA201-T4)
+ Fusing thermofuse . + Main board (CN106-A2, -A5, -B11, -B14, -B15)

SC Code E-4: Hot Roller Thermistor Short


-DefinitionThe resistance of the the hot roller thermistor is less than 0.11 K.
<Point to check>
+ Hot roller thermistor . + Main board (CN106-A2, -A5, -B11, -B14, -B15)

SC Code E-5: Pressure Roller Thermistor Open


-DefinitionThe resistance of the pressure roller thermistor is more than 0.53 M.
<Point to check>
+ Pressure roller thermistor .
+ Main board (CN106-A2, -A4, -B12, -B14, -B15)

SC Code E-6: Pressure Roller Thermistor Short


-DefinitionThe resistance of the pressure roller thermistor is less than 0.55 K.
<Point to check>
+ Pressure roller thermistor .
+ Main board (CN106-A2, -A5, -B11, -B14, -B15)

FW 740/750

SC Code E-7: Fusing Overheat


-DefinitionThe temperature detected by the hot roller thermistor becomes higher than
250C
<Point to check>
+ Hot roller thermistor . + Fusing thermofuse
+ AC drive board (T202-2, RA201-T4) .
+ Main board (CN106-A2, -B14, -B15)

SC Code E-8: Fusing Warm-up Error


-DefinitionThe temperature detected by the hot roller thermistor does not reach the
target ready temperature within 12 minutes after main switch is turned on.
<Point to check>
+ Hot roller thermistor . + Fusing lamp . + Fusing thermofuse
+ AC drive board (T202-2, RA201-T4) .
+ Main board (CN106-A2, -A5, -B11, -B14, -B15) .
+ AC harness

SC Code E-9: Toner Density Sensor Abnormal


-DefinitionThe toner density sensor voltage is less than 0.5 volts or more than 4.5 volts.
NOTE: This condition is not detected until 251 copies since initializing
developer.
<Point to check>
+ Toner density sensor .
+ Flow of the developer at the toner density sensor area
+ Main board (CN104-A10, -A11, -B20, -B21)

SC Code E-10: Main Motor Abnormal


-DefinitionThe main board does not receive a signal from the main motor for 2 seconds
while the main motor is on.
<Point to check>
+ Main motor .
+ Mechanical interference of the main motor drive
+ Main board (CN106-A12, -A13)

SC Code E-11: Toner Density Sensor adjustment Error


-DefinitionThe toner density sensor voltage cannot be adjusted to its standard value (4.1
0.1 volts) during the new developer initialization.
NOTE: If clearing the SC condition, the previous data of SP#-30 is still
used until its next initialization.
<Point to check>
+ Toner density sensor . + Developer
+ Flow of the developer at the toner density sensor area
+ Main board (CN104-A10, -A11, -B20, -B21)

FW 740/750

SC Code E-14: Zero Cross Signal Detection Abnormal


- Definition The zero cross signal is not detected within 0.5 second after the main switch is
turned on.
- Points to check + Main board
+ AC Drive board