1.

General Contractor shall visit the site, review the building shell drawings as submitted by
the Landlord or Starbucks Site Surveyor, and become thoroughly familiar with the site
conditions prior to bidding or construction.
2. General Contractor shall consult with Starbucks Construction Manager to resolve any
changes, omissions, or plan discrepancies prior to bidding or construction.
3. All work shall be performed in strict compliance with local, county, state, and federal codes
and ordinances.

Mailing Address: Starbucks Coffee Company


2401 Utah Avenue South
MS Stop: S-SD10
Seattle, Washington 98134
(206) 318-1575
Design Manager: Melissa Bodway
Starbucks Coffee Company
455 North Point Street, 2nd Floor
San Francisco, California 94133
(415) 241-0256 x2287

Room Schedule
Name
Backbar
Cafe Seating
Retail
Unisex Restroom
Vestibule
Workroom
Grand total

Vicinity Plan
Area

361 SF
818 SF
173 SF
101 SF
31 SF
374 SF
1857 SF

R
C 2011 Starbucks Coffee Company

4. General Contractor shall verify the location of all utilities.

7. The General Contractor is responsible for obtaining permits for fire protection, plumbing,
mechanical, and electrical systems prior to installation of such systems.
8. General Contractor shall retain one set of the plans to note and document all changes
during construction. This set shall be a part of the General Contractors Store Close-out
Package as described in the Construction Management Agreement.
9. General Contractor is responsible for coordinating delivery of materials from Starbucks
contracted Third Party Logistics distribution services and Vendor Direct shipments. Refer to
Construction Management Agreement for methods and lead times.
10. Responsibility for supply and delivery of materials and equipment is identified in the
drawing schedule sheets under the column labeled "Responsibility".
11. For the purpose of the documents, to install, shall mean to provide all fasteners,
miscellaneous hardware, blocking, electrical connections, plumbing connections, and other
items required for a complete and operation installation, unless otherwise noted.
12. All item substitutions must be approved by the Starbucks Design Manager.
13. Refer to item cutsheets for additional information.

Landlord: Willits Town Center LLC c/o


Mariner Real Estate Management LLC
4601 College Blvd, Ste 300
Leawood, Kansas 66211
(816) 285-3875 phone
Architect of Record: Tom Spader
Freiheit & Ho Architects Inc., P.S.
5209 Lake Washington Blvd NE, Ste
200
Kirkland, Washington 98033
(425) 827-2100 phone
(425) 828-6899 fax
Electrical Engineer: Thom Evert
Corey Electrical Engineering, Inc.
7822 S. Wheeling Ct., Suite B
Englewood, Colorado 80112
(303) 696-1257 phone
(303) 696-1459 fax
Mechanical/Plumbing Brian Seyferth
Engineer: Brian Seyferth & Associates, Inc.
5583 S. Prince Street
Littleton, Colorado 80125
(303) 797-7772 phone
(303) 797-7773 fax

Site and Occupancy


Project Description:
Zoning:
Type of Use:
Type of Occupancy:

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Zone 3 (Willits Town Center PUD)


Retail Sales and Service

Code Information

A-2

Type of Construction:

VB, Sprinklered

Total Square Footage:

1,857 s.f.

Occupancy Load:

3/4/2013 12:58:46 PM

Commercial tenant improvement to a new tenant space

Retail:
Seating:
Beverage/Prep:
Workroom/Storage:

173 s.f. / 30 = 6
818 s.f. / 15 = 55
361 s.f. / 200 = 2
374 s.f. / 300 = 2
total occupancy = 65

2006 International Building Code (IBC)


2006 International Mechanical Code (IMC)
2006 International Plumbing Code (IPC)
2005 National Electrical Code (NEC)
2006 International Energy Conservation Code (IECC)
2003 ICC/ANSI 117.1 Accessibility Code
2006 International Fire Code (IFC)
2006 International Fuel Gas Code (IFGC)

Starbucks Coffee
Company

Abbreviations
3PL

Third Party Logistics

A/C
ACT
ADJ
AFF
AMP
ARCH

Air Conditioning
Acoustical Ceiling Tile
Adjustable
Above Finished Floor
Ampere
Architect

BOH

Back of House

CAB
CL
CLG
CM
CTR
CX
CXA

Cabinet
Center Line
Ceiling
Construction Manager
Center
Commissioning
Commissioning Agent

DEG
DET
DIA
DIM
DM
DN

Degree
Detail
Diameter
Dimension
Design Manager
Down

EA
EL
EQ
EXIST
EXT

Each
Elevation
Equal
Existing
Exterior

FF&E
FIO
FLR
FOH
FT

"Furniture, Fixture, and Equipment"


Furnished and Installed by Owner
Floor
Front of House
Foot/Feet

G
GC

Ground
General Contractor

HC
HDW
HM
HORIZ
HR
HT
HVAC

Hollow Core
Hardware
Hollow Metal
Horizontal
Hour
Height
"Heating, Ventilating, and Air Conditioning"

Interior Seating:

37 seats x 5% = 2 ADA required (2 provided)

ID

Inside Diameter

Exterior Seating:

28 seats x 5% = 2 ADA required (2 provided)

LL

Landlord

MAX
MEP
MFR
MIN

Maximum
"Mechanical, Electrical, and Plumbing"
Manufacturer
Minimum

NIC
NL
NTS

Not in Contract
Night Light
Not to Scale

OC
OD
OF/CI
OF/OI

On Center
Outside Diameter
Owner Furnished/Contractor Installed
Owner Furnished/Owner Installed

PD
PLC
PM

Production Designer
Place
Project Manager

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575
These Drawings and Specifications are confidential
and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Rev

Sheet
North Arrow

PXXX-ES

Paint Tag

Exterior Elevation

XXXXX

Design ID Tag

Interior Elevation

XXXXX

Section Callout

Detail Callout

Door/Window Tag

Datum Point

X'-XX" AFF Above Finished Floor


Height Tag

XX

Revision Tag

R
Radius
RCM
Renovations Construction Manager
REF
Reference
REQ(D) Require(d)
REV
Revision
RND
Round

XX

Wall Type Tag

Keynote Tag

X' XX"
SB
SC
SF
SHT
SIM
SPEC
SQ

Starbucks
Solid Core
Square Feet
Sheet
Similar
Specification
Square

TEMP
TYP

Temporary
Typical

UON

Unless Otherwise Noted

VD
VERT
VIF

Vendor Direct
Vertical
Verify in Field

Revision Cloud

Revision Schedule
By
Description

Index of Sheets

Symbol Legend

Date

Dimension Line from


Finish Face to Finish Face

Sheet Title

General
G-001
G-010
G-011
G-012
G-013

General Information
Design Specifications - Commercial Interiors
Design Specifications - Commercial Interiors
Design Specifications - Commercial Interiors
Design Specifications - Commercial Interiors

Architectural
A-101
A-102
A-103
A-201
A-202
A-600

Architectural Site Plan


Site Details
Site Details
Exterior Elevations
Exterior Elevations
Flashing Details

Interiors
I-101
I-112
I-113
I-114
I-115A
I-115B
I-116
I-117
I-118
I-119
I-211
I-212
I-213
I-401
I-402
I-501
I-502
I-503
I-504
I-505
I-506
I-507
I-508
I-509
I-601
I-602

Code/Accessibility Plan
Floor Plan
Penetration Plan
FF and E Plan
Casework Plan
Upper Casework Plan
Reflected Ceiling Plan
Lighting Plan
Floor Finish Plan
Wall Finish Plan
Interior Elevations
Interior Elevations
Interior Elevations
Enlarged Restroom Plan and Elevations
Restroom Details
Casework Details
Casework Details
Casework Details
Casework Details
Casework Details
Casework Details
Design Details
Design Details
Design Details
Schedules
Schedules

Mechanical
M100
M200

Mechanical Legend, Notes & Details


Mechanical Plan, Schedule & Notes

Electrical
E001
E100
E110
E111
E112
E113
E200
E210

Plumbing
P100
P200
P300
P400
P500

Electrical Specifications
Electrical Site Plan
Penetration Plan
Power Plan
Signage, Lighting Plan & Schedule
Roof Power Plan
Typical Details
Panel Schedules, One-Line Diagram & Energy
Code Compliance

Plumbing Notes and Details


Plumbing Plan
Waste Plan
Isometrics
Gas Piping Plan

Highway 82 & Willits

6. General Contractor shall patch and repair all existing walls, floors, ceilings, or other
surfaces identified to remain that may become damaged during the course of the work.

Construction Steve Burroughs


Manager: Starbucks Coffee Company
6380 S. Fiddlers Green Circle, Ste 450
Greenwood Village, Colorado 80111
(303) 267-7231 phone

Project Name:

5. General Contractor to verify all dimensions, including clearances required by other trades,
and notify Starbucks Construction Manager of any discrepancies prior to proceeding with the
work. All dimensions are to the face of the finished surface unless noted otherwise. All
dimensions to be taken from designated datum point. Do not scale drawings.

719 East Valley Road


Basalt, Colorado 81621
Eagle County

Project Contacts

Project Address:

General Notes

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

Sheet Title:

General Information
As indicated

Scale:

Sheet Number:

G-001

3/4/2013 12:58:50 PM

SECTION 01574 - CONSTRUCTION INDOOR AIR QUALITY MANAGMENT PLAN


1.1
SUMMARY
A.
Section Includes:
1.
Description of a construction Indoor Air Quality (IAQ) Management Plan.
2.
IAQ construction requirements.
1.2
INDOOR AIR QUALITY
A.
Goals: The Owner has set the following indoor air quality goals for jobsite operations on
the project, within the limits of the construction schedule, Contract Sum, and available materials,
equipment, products and services. Goals include:
1.
Protect workers on the site from undue health risks during construction.
2.
Prevent residual problems with indoor air quality in the completed building.
1.3
REFERENCES:
A.
SMACNA IAQ Guidelines for Occupied Buildings Under Construction, 1995.
1.4
CONSTRUCTION IAQ MANAGEMENT PLAN
A.
HVAC Protection: Contractor to avoid using permanent HVAC equipment. When not
used, system is to be sealed. All penetrations, duct openings will be sealed immediately at the time
of installation. When use of permanent HVAC equipment is unavoidable, all supply and return grills
and openings are to have temporary filters of Merv 8 installed. HVAC equipment is not to be used
during demolition and sanding activities.
B.
Provide temporary exhaust fans to maintain space air pressure negative to the outside.
C.
Use vacuum-assisted power tools whenever feasible (i.e. drywall sanders and concrete
saws). Clean site daily with dust suppression techniques (wet mop, HEPA vacuum).
Remove spills and excess applications immediately. Use low VOC, non-toxic cleansers only.
D.
Delivery of all materials, fixtures, equipment, and furniture will be directed to vacant
available indoor space. All cartons and removed materials, etc. are to be kept
clean and dry at all times. Any excessive indoor moisture to be addressed immediately by GC.
E.
Temporary construction entry mats will be provided and maintained to retain
effectiveness to remove debris during construction.
F.
All volatile liquids and solvents to be kept tightly sealed when not in use and stored
outside of tenant space.
G.
Avoid the use of gas powered tools and equipment. When gas engines are unavoidable, do
not allow engine to idle inside indoor space.
H.
GC to include IAQ inspections within the weekly job reports, including photos and a
tracking sheet.
I.
Begin Before Occupancy flush-out immediately after all finishes have been installed.
Replace all filtration media prior to flush-out. Flush-out with 100% outside air. Maintain an interior
air temperature of at least 60 F during flush-out period. Flush-out for 24 hours a day until a
minimum of 3,500 cu. ft./sq. ft. of floor area has been achieved. Begin During Occupancy flushout at time of store turnover. Rate of outside air must be at least 0.30 cfm/sq. ft. Begin flush-out
each day three hours prior to store occupancy and continue through days occupancy. Continue
flush-out until a total of 14,000 cu. ft./sq. ft. of floor area has been achieved. At the end of flush-out
provide new filters.
END OF SECTION 01574

Site Construction

SECTION 01524 - CONSTRUCTION WASTE MANAGEMENT


1.1
SUMMARY
A.
Salvaging nonhazardous demolition and construction waste.
B.
Recycling nonhazardous demolition and construction waste.
C.
Disposing of nonhazardous demolition and construction waste.
1.2
DEFINITIONS
A.
Construction Waste: Building and site improvement materials and other solid waste resulting
from construction, remodeling, renovation, or repair operations. Construction waste includes
packaging.
B.
Demolition Waste: Building and site improvement materials resulting from demolition or
selective demolition operations.
C.
Disposal: Removal off-site of demolition and construction waste and subsequent sale,
recycling, reuse, or deposit in landfill or incinerator acceptable to authorities having
jurisdiction.
D.
Recycle: Recovery of demolition or construction waste for subsequent processing in
preparation for reuse.
E.
Salvage: Recovery of demolition or construction waste and subsequent sale or reuse in
another facility.
F.
Salvage and Reuse: Recovery of demolition or construction waste and subsequent
incorporation into the Work.
1.3
PERFORMANCE REQUIREMENTS
A.
End-of-Project Rates for Salvage/Recycling: [50] [75] percent.
1.4
WASTE MANAGEMENT PLAN
A.
Types and quantities of demolition and construction waste.
B.
Type of waste and whether it will be salvaged, recycled, or disposed of in landfill or
incinerator.
C.
Net additional cost or net savings resulting from waste management plan.
1.5
LEED SUBMITTAL
A.
Waste Reduction Progress Reports: Concurrent with each Application for Payment, submit
completed reporting template.
B.
Indicate receipt and acceptance of waste material by accepting and processing facilities
licensed to accept them. Include manifests, type of material, weight tickets, receipts, and
invoices.
1.6
RECYCLING WASTE
A.
Recycling Incentives: Revenues and other incentives for recycling will accrue to Owner.
END OF SECTION 01524

SECTION 02220 - SELECTIVE STRUCTURE DEMOLITION


1.1
SUMMARY
A.
Demolition and removal of [portions of a building or structure] [selected site elements].
B.
Historic items removed and salvaged for Owner.
1.2
SUBMITTALS
A.
Qualification Data: For demolition firm, refrigerant recovery technician.
B.
Schedule of Selective Demolition Activities: Indicate the following:
1.
Detailed sequence of selective demolition and removal work, with starting and ending
dates for each activity. Ensure Owner's building manager's and other tenants' on-site
operations are uninterrupted.
2.
Interruption of utility services. Indicate how long utility services will be interrupted.
3.
Coordination for shutoff, capping, and continuation of utility services.
4.
Use of elevator and stairs.
5.
Locations of proposed dust- and noise-control temporary partitions and means of egress,
including for other tenants affected by selective demolition operations.
6.
Coordination of Owner's continuing occupancy of portions of existing building and of
Owner's partial occupancy of completed Work.
7.
Means of protection for items to remain and items in path of waste removal from building.
1.3
PROJECT CONDITIONS
A.
Owner will[ not] occupy portions of building immediately adjacent to selective demolition area.
B.
Hazardous Materials: Unknown whether hazardous materials will be encountered. If encountered,
Owner will remove hazardous materials under a separate contract.
1.4
WARRANTY
A.
Existing Warranties: <Insert list of existing warranties affected by selective demolition.>
1.5
EXECUTION
A.
Utility Services and Mechanical/Electrical Systems: Maintained to occupied facilities.
1.
Shut Off: By [Owner] [Building manager] [Contractor].
B.
Site Access and Temporary Controls: Minimum interference with roads, streets, walks, walkways,
and other adjacent occupied and used facilities
C.
Temporary Facilities:
1.
Temporary barricades to prevent injury to people.
2.
Temporary weather protection.
3.
Protection of existing finish work to remain.
4.
Protection of furnishings and equipment.
D.
Temporary shoring.
E.
Removed and Salvaged Items: Cleaned, crated, stored, and transported to Owner's [on] [off]-site
storage area.
F.
Removed and Reinstalled Items: Cleaned, repaired, crated, stored, and reinstalled.
G.
Existing Items to Remain: Existing construction protected against damage.
H.
Disposal of Demolished Items:
1.
Burning: Not permitted.
2.
Disposal: Comply with requirements in General Conditions of the Contract.
END OF SECTION 02220

SECTION 02225 - CUTTING AND PATCHING


1.1
SUMMARY
A.
Cutting and patching required by the following:
1.
Installation of other materials.
2.
Finishing.
3.
Alterations.
4.
Tests and inspections.
1.2
QUALITY ASSURANCE
A.
Limitations on Cutting and Patching:
1.
Structural Elements: <Insert list of elements that requires Architect's approval.>
2.
Operational Elements: <Insert list of elements that requires Architect's approval.>
3.
Miscellaneous Elements: <Insert list of elements that requires Architect's approval.>
4.
Visual Requirements: <Insert list of exposed Work that affects aesthetic qualities.>
1.3
WARRANTY
A.
Existing Warranties: <Insert list of warranties affected by cutting and patching.>
1.4
MATERIALS
A.
In-Place Materials: <Insert list of unusual materials that must be matched.>
1.5
EXECUTION
A.
Temporary support of Work being cut.
B.
Existing Utility Services and Mechanical/Electrical Systems: Services/systems bypassed
before cutting to [minimize] [prevent] interruption to occupied areas.
C.
Cutting: Using hand or small power tools.
D.
Patching: With seams that are as invisible as possible.
END OF SECTION 02225

SECTION 03300 - CAST-IN-PLACE CONCRETE


1.1
SUMMARY
A.
Cast-in-place concrete, including formwork, reinforcement, concrete materials, mixture design,
placement procedures, and finishes, for the following:
1.
Footings.
2.
Foundation walls.
3.
Slabs-on-grade.
1.2
SUBMITTALS
A.
Product Data: For each type of product indicated.
B.
Shop Drawings:
1.
Reinforcing:
a.
Detail reinforcing in accordance with ACI 315. Indicate reinforcement sizes,
spacings, locations and quantities of reinforcing, bending and cutting schedules,
splicing, and supporting and spacing devices.
b.
Indicate embedded items.
2.
Slab Layouts: Dimension locations of control, expansion, and construction joints. Relate to
building grid lines.
C.
Design Mixtures: For each concrete mixture. Submit alternate design mixtures when characteristics
of materials, Project conditions, weather, test results, or other circumstances warrant adjustments.
1.
Indicate amounts of mixing water to be withheld for later addition at Project site.
D.
Certifications: Submit mill certificates for cement, aggregates, and reinforcing.
1.3
MATERIALS
A.
Steel Reinforcement:
1.
Reinforcing Bars: Deformed.
a.
Use salvaged bars whenever available.
b.
Minimum recycled content: 60%
2.
Plain-Steel Welded Wire Reinforcement: ASTM A 185, plain, fabricated from as-drawn
steel wire into flat sheets.
B.
Concrete Materials:
1.
Portland Cement: ASTM C 150, Type I, gray, supplemented with 50% [fly ash] [ground
granulated blast-furnace slag].
2.
Aggregate: Normal weight.
3.
Water: ASTM C 94/C 94M.
4.
Admixtures: Provide admixtures certified by manufacturer to be compatible with other
admixtures and that will not contribute water-soluble chloride ions exceeding those
permitted in hardened concrete. Do not use calcium chloride or admixtures containing
calcium chloride.
a.
Air-Entrainment: ASTM C 260.
b.
Water-Reducing Admixture: ASTM C 494/C 494M, Type A.
c.
High-Range, Water-Reducing Admixture: ASTM C 494/C 494M, Type F.
d.
High-Range, Water-Reducing and Retarding Admixture: ASTM C 494/C 494M,
Type G.
e.
Accelerator ASTM C 494, Type C or E, non-corrosive, non-chloride.
C.
Fiber Reinforcement: Synthetic, polypropylene.
1.
Fibrillated polypropylene micro-fibers engineered and designed for use in concrete,
complying with ASTM C 1116/C 1116M, Type III
D.
Waterstops: Flexible rubber.
E.
Plastic Vapor Retarder: ASTM E 1745, Class A. Include manufacturer's recommended adhesive or
pressure-sensitive joint tape.
F.
Curing Materials: Waterborne, monomolecular film forming, manufactured for application to fresh
concrete.
G.
Related Materials:
1.
Expansion- and isolation-joint-filler strips ASTM D 1751, asphalt-saturated cellulosic fiber
or ASTM D 1752, cork or self-expanding cork.
2.
Bonding Agent: ASTM C 1059/C 1059M, Type II, non-redispersible, acrylic emulsion or
styrene butadiene.
3.
Non-Shrink Grouts: ASTM C 1107, Grade B; non-shrink non-catalyzed natural aggregate
grout; minimum compressive strength of 7000 PSI at 28 days; 25 to 30 second flow when
tested in accordance with ASTM C 939 at 45 to 90 degrees F; cement gray in color
4.
Form Release Coating: Water based type; VOC <150g/I; Nox-Crete Utility Release.
Cresset Chemical Company Crete 20_VOC, or approved; non staining.
H.
Repair Materials:
1.
Repair Underlayment: Cement-based, polymer-modified, self-leveling product that can be
applied in thicknesses from 1/8 inch(3.2 mm) and that can be feathered at edges to match
adjacent floor elevations.
a.
Cement Binder: ASTM C 150, portland cement or hydraulic or blended hydraulic
cement as defined in ASTM C 219.
b.
Primer: Product of underlayment manufacturer recommended for substrate,
conditions, and application.
c.
Aggregate: Well-graded, washed gravel, 1/8 to 1/4 inch(3.2 to 6 mm) or coarse
sand as recommended by underlayment manufacturer.
d.
Compressive Strength: Not less than 4100 psi(29 MPa) at 28 days when tested
according to ASTM C 109/C 109M.
2.
Repair Overlayment: Cement-based, polymer-modified, self-leveling product that can be
applied in thicknesses from 1/8 inch(3.2 mm) and that can be feathered at edges to match
adjacent floor elevations.
a.
Cement Binder: ASTM C 150, portland cement or hydraulic or blended hydraulic
cement as defined in ASTM C 219.
b.
Primer: Product of topping manufacturer recommended for substrate, conditions,
and application.
c.
Aggregate: Well-graded, washed gravel, 1/8 to 1/4 inch(3.2 to 6 mm) or coarse
sand as recommended by topping manufacturer.
d.
Compressive Strength: Not less than 5000 psi(34.5 MPa) at 28 days when tested
according to ASTM C 109/C 109M.
1.4
INSTALLATION
A.
Floor and Slab Finishes:
1.
Float: Surfaces to receive trowel finish.
2.
Trowel: Surfaces exposed to view, and surfaces to be covered with resilient flooring,
carpet, ceramic or quarry tile set over a cleavage membrane, paint, or another thin-filmfinish coating system.
3.
Trowel and Fine Broom: Surfaces to be covered with ceramic or quarry tile installed by
either thickset or thin-set method.
4.
Broom: Exterior concrete platforms, steps, and ramps.
1.5
FIELD QUALITY CONTROL
A.
Testing: By [Owner] [Contractor]-engaged agency.
B.
Inspections: By Owner-engaged special inspector.
END OF SECTION 03300

SECTION 03350 - CONCRETE FINISHING


1.1
SUMMARY
A.
Section Includes:
1.
Concrete Sealer
2.
Colored Concrete Sealer.
1.2
SUBMITTALS
A.
Qualification Data: For qualified Applicator.
B.
Maintenance Data: For SealSource to include in maintenance manuals.
C.
Warranty: Special warranties specified in this Section
1.3
WARRANTY
A.
Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or
replace color sealant that fail(s) in materials or workmanship within specified warranty
period.
1.
Warranty Period: Five years from date of Substantial Completion.
1.4
MANUFACTURERS
A.
Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
1.
SealSource, LC.
2.
Ameripolish
1.5
CONCRETE SEALER
A.
VOC Content: Liquid floor treatments shall have a VOC content of 200 g/L or less when
calculated according to 40 CFR 59, Subpart D (EPA Method 24).
B.
SealSource Harden X Salt Guard
C.
Ameripolish Proguard Stain Shield
1.6
COLORED CONCRETE SEALER
A.
VOC Content: Liquid floor treatments shall have a VOC content of 200 g/L or less when
calculated according to 40 CFR 59, Subpart D (EPA Method 24).
B.
SealSource KromaPolish.
C.
Ameripolish Solvent Based Dye
1.7
PREPARATION
A.
Inspect existing slab for excessive cracking, spalling, or rock pockets. Clean deficient areas
and patch with an all-purpose, non-shrink, cementitios grout.
B.
Aggressively grind concrete to expose large aggregate.
END OF SECTION 03350

R
C 2011 Starbucks Coffee Company

Starbucks Coffee
Company
2401 Utah Avenue South
Seattle, Washington 98134
(206) 318-1575
These Drawings and Specifications are confidential
and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Rev

Date

Revision Schedule
By
Description

719 East Valley Road


Basalt, Colorado 81621
Eagle County

SECTION 01420 - REFERENCES


PART 1 - GENERAL
1.1
INDUSTRY STANDARDS
A.
Applicability of Standards: Unless the Contract Documents include more stringent requirements,
applicable construction industry standards have the same force and effect as if bound or copied
directly into the Contract Documents to the extent referenced. Such standards are made a part of
the Contract Documents by reference.
B.
Publication Dates: Comply with standards in effect as of date of the Contract Documents unless
otherwise indicated.
C.
Copies of Standards: Each entity engaged in construction on Project should be familiar with
industry standards applicable to its construction activity. Copies of applicable standards are not
bound with the Contract Documents.
1.
Where copies of standards are needed to perform a required construction activity, obtain
copies directly from publication source.
1.2
ABBREVIATIONS AND ACRONYMS
A.
Industry Organizations: Where abbreviations and acronyms are used in Specifications or other
Contract Documents, they shall mean the recognized name of the entities in the following list.
ACI
American Concrete Institute
AHA
American Hardboard Association
AITC
American Institute of Timber Construction
ANSI
American National Standards Institute
APA
APA - The Engineered Wood Association
ASHRAE
American Society of Heating, Refrigerating and Air-Conditioning Engineers
ASTM
ASTM International (American Society for Testing and Materials International)
AWI
Architectural Woodwork Institute
AWPA
American Wood Protection Association (Formerly: American Wood Preservers'
Association)
CRI
Carpet and Rug Institute (The)
CRRC
Cool Roof Rating Council
CSA
Canadian Standards Association
CSA
CSA International (Formerly: IAS - International Approval Services)
CSI
Construction Specifications Institute (The)
ETL SEMCO
Intertek ETL SEMCO (Formerly: ITS - Intertek Testing Service NA)
FM Global
FM Global (Formerly: FMG - FM Global)
FSC
Forest Stewardship Council
HPVA
Hardwood Plywood & Veneer Association
ITS
Intertek Testing Service NA (Now ETL SEMCO)
MFMA
Maple Flooring Manufacturers Association, Inc.
MPI
Master Painters Institute
NFPA
NFPA (National Fire Protection Association)
NOFMA
NOFMA: The Wood Flooring Manufacturers Association (Formerly: National Oak
Flooring Manufacturers Association)
OPL
Intertak
SDI
Steel Door Institute
SMACNA
Sheet Metal and Air Conditioning Contractors' National Association
UL
Underwriters Laboratories Inc.
USGBC
U.S. Green Building Council
WCLIB
West Coast Lumber Inspection Bureau
WI
Woodwork Institute (Formerly: WIC - Woodwork Institute of California)
B.
Code Agencies: Where abbreviations and acronyms are used in Specifications or other Contract
Documents, they shall mean the recognized name of the entities in the following list.
DIN
Deutsches Institut fur Normung e.V.
ICC
International Code Council
ICC-ES
ICC Evaluation Service, Inc.
C.
Federal Government Agencies: Where abbreviations and acronyms are used in Specifications or
other Contract Documents, they shall mean the recognized name of the entities in the following
list.
EPA
Environmental Protection Agency
D.
Standards and Regulations: Where abbreviations and acronyms are used in Specifications or
other Contract Documents, they shall mean the recognized name of the standards and regulations
in the following list.
ADAAG
Americans with Disabilities Act (ADA)
Architectural Barriers Act (ABA)
Accessibility Guidelines for Buildings and Facilities
Available from U.S. Access Board
CFR
Code of Federal Regulations
Available from Government Printing Office
E.
State Government Agencies: Where abbreviations and acronyms are used in Specifications or
other Contract Documents, they shall mean the recognized name of the entities in the following
list.
CDHS
California Department of Health Services
CDPH
California Department of Public Health, Indoor Air Quality Section
END OF SECTION 01420

Concrete

Project Address:

SECTION 01352 - SUSTAINABLE DESIGN REQUIREMENTS


1.1
SUMMARY
A.
This Section includes general requirements and procedures for compliance with certain U.S.
Green Building Council's (USGBC) LEED prerequisites and credits needed for the Project to
obtain LEED [Certified] [Silver] [Gold] [Platinum] certification based on [LEED for Retail-NC,
Pilot] [LEED for Retail-CI, Pilot].
1.
Other LEED prerequisites and credits needed to obtain LEED certification are
dependent on material selections and may not be specifically identified as LEED
requirements. Compliance with requirements needed to obtain LEED prerequisites and
credits may be used as one criterion to evaluate substitution requests.
2.
Additional LEED prerequisites and credits needed to obtain the indicated LEED
certification are dependent on the Architect's design and other aspects of the Project
that are not part of the Work of the Contract.
1.2
DEFINITIONS
A.
Certificates of Chain-of-Custody: Certificates signed by manufacturers certifying that wood used
to make products was obtained from forests certified by an FSC-accredited certification body to
comply with FSC 1.2, "Principles and Criteria." Certificates shall include evidence that mill is
certified for chain-of-custody by an FSC-accredited certification body.
B.
LEED: Leadership in Energy & Environmental Design.
C.
Rapidly Renewable Materials: Materials made from agricultural products that are typically
harvested within a ten-year or shorter cycle. Rapidly renewable materials include products made
from bamboo, cotton, flax, jute, straw, sunflower seed hulls, vegetable oils, or wool.
D.
Regionally Manufactured Materials: Materials that are manufactured within a radius of 500 miles
(800 km) from the Project location. Manufacturing refers to the final assembly of components
into the building product that is installed at the Project site.
E.
Regionally Extracted, Harvested, or Recovered Materials: Materials that are extracted,
harvested, or recovered and manufactured within a radius of 500 miles (800 km) from the Project
site.
F.
Recycled Content: The percentage by weight of constituents that have been recovered or
otherwise diverted from the solid waste stream, either during the manufacturing process (preconsumer), or after consumer use (post-consumer).
1.
Spills and scraps from the original manufacturing process that are combined with other
constituents after a minimal amount of reprocessing for use in further production of the
same product are not recycled materials.
2.
Discarded materials from one manufacturing process that are used as constituents in
another manufacturing process are pre-consumer recycled materials.
1.3
SUBMITTALS
A.
Project Materials Cost Data: Provide statement indicating total cost for materials used
for Project. Costs exclude labor, overhead, and profit. Include breakout of costs for the
following categories of items:
1.
Divisions 2-10.
2.
Divisions 1, 13, and 14.
3.
Division 12.
4.
Plumbing.
5.
Wood-based construction materials.
B.
LEED Action Plans: Provide preliminary submittals within [seven] [14] <Insert number>
days of date established for [the Notice to Proceed] [the Notice of Award] indicating how
the following requirements will be met.
1.
Credit MR 2, Construction Waste Management: Waste management plan
complying with Division 1 Section "Construction Waste Management."
2.
Credit MR 3, Resource Reuse: List of proposed salvaged and refurbished
materials.
a.
Identify each material that will be salvaged or refurbished, its source,
and cost.
3.
Credit MR 4, Recycled Content: List of proposed materials with recycled content.
a.
Indicate cost, post-consumer recycled content, and pre-consumer
recycled content for each product having recycled content.
4.
Credit MR 5.1[ and 5.2], Regional Materials: List of proposed regionally
manufactured materials[ and regionally extracted, harvested, or recovered
materials].
a.
Identify each regionally manufactured material, its source, and cost.
b.
Identify each regionally extracted, harvested or recovered material, its
source, and cost.
5.
Credit MR 7.0, Certified Wood: List of proposed certified wood products.
a.
Indicate each product containing certified wood, its source, and cost.
b.
Include statement indicating total cost for wood-based materials used
for Project, including non-rented temporary construction.
6.
Credit EQ3.1, Construction IAQ Management Plan, During Construction: Proposed
revisions to the Construction IAQ Plan Template complying with SMACNA IAQ Guidelines
for Occupied Buildings Under Construction, 1995.
C.
LEED Progress Reports: Concurrent with each Application for Payment, submit reports
comparing actual construction and purchasing activities with LEED action plans for the
following:
1.
Credit MR 2.1[ and Credit MR 2.2]: Waste reduction progress reports complying
with Division 1 Section "Construction Waste Management."
2.
Credit MR 3: Salvaged and refurbished materials.
3.
Credit MR 3.1[ and Credit MR 3.2]: Salvaged and refurbished materials.
4.
Credit MR 4.1[ and Credit MR 4.2]: Recycled content.
5.
Credit MR 5.1[ and Credit MR 5.2]: Regional materials.
6.
Credit MR 5.1[ and Credit MR 5.2]: Regionally manufactured materials[ and
regionally extracted and manufactured materials].
7.
Credit [MR 6] [MR 7]: Certified wood products.
D.
LEED Documentation Submittals:
1.
Credit SS 7.4, Heat Island Effect, Roof: Product Data for roofing materials
indicating Solar Reflective Index.
2.
Credit WE 1, Water Use Reduction: Data and cutsheets for all waterclosets,
urinals and flushometers.
3.
Credit MR 2, Construction Waste Management: Comply with Division 1 Section
"Construction Waste Management."
4.
Credit MR 3, Resource Reuse: Receipts for salvaged and refurbished materials
used for Project, indicating sources and costs for salvaged and refurbished
materials.
5.
Credit MR 4, Recycled Content: Product Data and certification letter indicating
percentages by weight of post-consumer and pre-consumer recycled content for
contractor procured products having recycled content. Include statement
indicating costs for each product having recycled content.
6.
Credit MR 5.1[ and Credit MR 5.2], Regional Materials: Product data indicating
location of material manufacturer for regionally manufactured materials. Include
statement indicating cost for each regionally manufactured material[ and for
each regionally extracted and manufactured material].
a.
Include statement indicating distance from manufacturer to Project for
each regionally manufactured material.
b.
Include statement indicating location of and distance from Project to
point of extraction, harvest, or recovery for each raw material used in
regionally extracted and manufactured materials.
7.
Credit MR 7.0, Certified Wood: Product Data and certificates of chain-of-custody
for products containing certified wood.
a.
Include statement indicating costs for each product containing certified
wood.
b.
Include statement indicating total cost for wood-based materials used for
Project, including non-rented temporary construction.
8.
Credit EQ 3.1, Construction IAQ Management Plan, During Construction:
a.
Product Data for temporary filtration media.
b.
Product Data for filtration media used during occupancy.
c.
Construction Documentation: Six photographs at three different
occasions during construction along with a brief description of the
SMACNA approach employed, documenting implementation of the IAQ
management measures, such as protection of ducts and on-site stored or
installed absorptive materials.
9.
Credit EQ 3.2, Construction IAQ Management Plan, Before Occupancy:
a.
Signed statement describing the building air flush-out procedures
including the dates when flush-out was begun and completed and
statement that filtration media was replaced after flush-out.
10.
Credit EQ 4A, Low-Emitting Materials, Adhesives and Sealants: Product data for
adhesives and sealants used inside the weatherproofing system indicating VOC
content of each product used. Indicate VOC content in g/L calculated according
to 40 CFR 59, Subpart D.
11.
Credit EQ 4B, Low-Emitting Materials, Paints and Coatings: Product data for
paints and coatings used inside the weatherproofing system indicating[ chemical
composition and] VOC content of each product used. Indicate VOC content in
g/L calculated according to 40 CFR 59, Subpart D.
12.
Credit EQ 4D, Low-Emitting Materials, Composite Wood: Product data for
products containing composite wood or agrifiber products or wood glues
indicating that they do not contain urea-formaldehyde resin.
13.
Credit EQ 4F, Low-Emitting Materials, Ceiling and Wall Systems: Product data
for all gypsum board, insulation, acoustical ceiling systems and wall coverings
installed in the building interior showing low-emitting certification.
END OF SECTION 01352

General Conditions (Continued)

Highway 82 & Willits

General Conditions (Continued)

Project Name:

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

General Conditions

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

LEED

AP:

Production Designer:
Checked by:
Sheet Title:

Design Specifications Commercial Interiors


1/4" = 1'-0"

Scale:

Sheet Number:

G-010

SECTION 05500 - METAL FABRICATIONS


1.1
SUMMARY
A.
Steel framing and supports for mechanical and electrical equipment.
B.
Steel framing and supports for applications where framing and supports are not specified in
other Sections.
C.
Shelf angles.
D.
Metal bollards.
1.2
SUBMITTALS
A.
Product Data: For the following:
1.
Paint products.
2.
Grout.
3.
All prefabricated products.
B.
Shop Drawings: Show fabrication and installation details for metal fabrications.
1.
Include plans, elevations, sections, and details of metal fabrications and their
connections. Show anchorage and accessory items.
2.
Provide templates for anchors and bolts specified for installation under other
Sections.
C.
Welding certificates.
1.3
PRODUCTS
A.
Materials: Steel plates, shapes, and bars, steel pipe, slotted channel framing.
1.
Provide steel W-shapes, channels, angles, M-shapes, S-shapes with a minimum
recycled content of 60 percent.
B.
Miscellaneous Framing and Supports:
1.
Steel framing and supports for mechanical and electrical equipment, applications
where framing and supports are not specified in other Sections.
2.
Galvanize where indicated.
3.
Prime with zinc-rich primer where indicated.
C.
Loose steel lintels, galvanized at exterior walls.
D.
Shelf angles, galvanized.
E.
Steel weld plates and angles not specified in other Sections, for casting into concrete.
F.
Metal Bollards: Schedule 40 steel pipe.
END OF SECTION 05500

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Wood and Plastics


SECTION 06160 - ROUGH INTERIOR FRAMING
1.1
SUMMARY
A.
Wood blocking and nailers.
B.
Utility shelving.
C.
Plywood backing panels.
1.2
MATERIALS
A.
Wood-Preservative-Treated Lumber:
1.
Preservative Treatment: AWPA C2 with chemicals containing no arsenic or chromium.
a.
AWPA C31 (inorganic boron) may be used in protected locations.
2.
Application: Items indicated and as follows:
a.
Items in contact with roofing or waterproofing.
b.
Items in contact with concrete or masonry.
c.
Framing less than 18 inches(460 mm) above ground in crawlspaces.
d.
Floor plates installed over concrete slabs-on-grade.
B.
Fire-Retardant-Treated Materials:
1.
Interior Type A: Treated materials shall have a moisture content of 28 percent or less
when tested according to ASTM D 3201 at 92 percent relative humidity. Use where
exterior type is not indicated
2.
Application: Items indicated and as follows:
a.
Concealed blocking.
b.
Plywood backing panels.
C.
Dimension Lumber Framing: For items of dimension lumber size, provide Construction or No. 2
grade lumber with 19 percent maximum moisture content of any species.
D.
Plywood backing panels for telephone and electrical equipment: made with adhesives containing
no urea formaldehyde.
E.
Fasteners: Hot-dip galvanized steel where exposed to weather, in ground contact, in contact with
treated wood, or in area of high relative humidity.
1.
Construction Adhesive:
a.
VOC Limits: 70 g/L
2.
Wood Adhesive:
a.
VOC Limits: 30 g/L
3.
Contact Adhesive:
a.
VOC Limits: 80 g/L
END OF SECTION 06160

SECTION 06440 - PLASTIC PANELING


PART 1 - GENERAL
1.1
SUMMARY
A.
Section Includes the following:
1.
Glass-fiber reinforced plastic (FRP) wall paneling.
2.
Molding, adhesives, and joint sealants.
1.2
PLASTIC SHEET PANELING
A.
General: Gelcoat-finished, glass-fiber reinforced plastic panels complying with ASTM D 5319.
1.
Low-Emitting Materials: Paneling shall comply with the testing and product requirements
of the California Department of Health Services' "Standard Practice for the Testing of
Volatile Organic Emissions from Various Sources Using Small-Scale Environmental
Chambers."
2.
Nominal Thickness: Not less than 0.09 inches.
3.
Color: White.
4.
Molding Color: White.
5.
Surface Finish: Molded pebble texture.
1.3
ADHESIVES
A.
As recommended by plastic paneling manufacturer.
1.
VOC Limit: 50 g/L
1.4
ACCESSORIES
A.
Trim Accessories: Manufacturer's standard one-piece vinyl extrusions designed to retain and
cover edges of panels. Provide division bars, inside corners, outside corners, and caps as
needed to conceal edges.
1.
Color: White.
END OF SECTION 06440

SECTION 07841 - THROUGH-PENETRATION FIRESTOP SYSTEMS


1.1
SUMMARY
A.
This Section includes through-penetration firestop systems for penetrations through fireresistance-rated constructions, including both empty openings and openings containing penetrating
items.
1.2
PERFORMANCE REQUIREMENTS
A.
Provide through-penetration firestop systems with the following ratings determined per [ASTM E
814] [or] [UL 1479]:
1.
F-Rated Systems: F-ratings equaling or exceeding fire-resistance rating of constructions
penetrated.
2.
T-Rated Systems: For penetrations located outside wall cavities and outside fireresistance-rated shaft enclosures.
3.
L-Rated Systems: Where through-penetration firestop systems are indicated in smoke
barriers.
1.3
SUBMITTALS
A.
Product Data: For each type of product indicated.
1.4
QUALITY ASSURANCE
A.
Installer Qualifications: A firm approved by FMG according to FMG 4991, "Approval of Firestop
Contractors."
B.
Fire-Test-Response Characteristics: Tested per ASTM E 814 by [UL] [OPL] [ITS] <Insert name of
qualified testing and inspecting agency>.
1.5
MANUFACTURERS
A.
VOC Content of Interior Sealants: Provide interior sealants and sealant primers that comply with the
following limits for VOC content when calculated according to 40 CFR 59, Subpart D (EPA Method
24):
1.
Sealants: 250 g/L.
2.
Sealant Primers for Nonporous Substrates: 250 g/L.
3.
Sealant Primers for Porous Substrates: 775 g/L.
B.
Products: Subject to compliance with requirements, provide one of the through-penetration firestop
systems indicated for each application in the Through-Penetration Firestop System.
1.6
MATERIALS
A.
Accessories: [Permanent forming/damming/backing materials] [temporary forming
materials] [substrate primers] [collars] [and] [steel sleeves] as needed to comply with
performance requirements.
1.7
INSTALLATION
A.
Identification: Preprinted metal or plastic labels, permanently attached.
1.8
FIELD QUALITY CONTROL
A.
Inspection of Installed Firestop Systems: By Owner-engaged agency according to ASTM E 2174
requirements.
1.9
THROUGH-PENETRATION FIRESTOP SYSTEM SCHEDULE
A.
Firestop Systems for Metallic Pipes, Conduit, or Tubing:
1.
Type of Fill Materials: One or more of the following:
a.
Intumescent putty.
B.
Firestop Systems for Nonmetallic Pipe, Conduit, or Tubing:
1.
Type of Fill Materials: One or more of the following:
a.
Intumescent putty.
C.
Firestop Systems for Insulated Pipes:
1.
Type of Fill Materials: One or more of the following:
a.
Intumescent putty.
D.
Firestop Systems for Miscellaneous Electrical Penetrants:
1.
Type of Fill Materials: One or more of the following:
a.
Intumescent putty.
E.
Firestop Systems for Miscellaneous Mechanical Penetrants:
1.
Type of Fill Materials: One or both of the following:
a.
Latex sealant.
F.
Firestop Systems for Groupings of Penetrants:
1.
Type of Fill Materials: One or more of the following:
a.
Latex sealant.
b.
Intumescent wrap strips.
END OF SECTION 07841

SECTION 07920 - JOINT SEALANTS


1.1
QUALITY ASSURANCE
A.
Preconstruction compatibility and adhesion testing.
B.
Product testing.
C.
Preconstruction field-adhesion testing.
D.
Mockups.
1.2
MATERIALS
A.
VOC Content of Interior Sealants: Provide interior sealants and sealant primers that comply with the
following limits for VOC content when calculated according to 40 CFR 59, Subpart D (EPA Method
24):
1.
Sealants: 250 g/L.
2.
Sealant Primers for Nonporous Substrates: 250 g/L.
3.
Sealant Primers for Porous Substrates: 775 g/L.
B.
Elastomeric Joint Sealants: Liquid applied, chemically curing; ASTM C 920.
1.
Suitability for Contact with Food: Where elastomeric sealants are indicated for joints that
will come in repeated contact with food, provide products that comply with 21 CFR
177.2600.
2.
Multicomponent Nonsag Neutral-Curing Silicone Sealant ES-1.
3.
Single-Component Mildew-Resistant Neutral-Curing Silicone Sealant ES-2.
4.
Single-Component Mildew-Resistant Acid-Curing Silicone Sealant ES-3.
5.
Single-Component Mildew-Resistant Acid-Curing RTV Silicone Sealant ES-4.
6.
Multicomponent Nonsag Polyurea Sealant ES-5.
7.
Multicomponent Nonsag Polyurea Filler ES-6.
C.
Latex Sealant LS-1: Comply with ASTM C 834, Type P, Grade NF.
D.
Joint-Sealant Backing:
1.3
JOINT-SEALANT SCHEDULE
A.
Joint-Sealant Application JS-1: Exterior horizontal nontraffic and traffic isolation and contraction
joints in cast-in-place concrete slabs.
1.
Joint Sealant: ES-5.
B.
Joint-Sealant Application JS-2: Exterior perimeter joints between wall and frames of doors and
windows.
1.
Joint Sealant: ES-1.
C.
Joint-Sealant Application JS-3: Exterior control and expansion joints in horizontal traffic surfaces of
brick pavers, ceramic tile, stone paving units, concrete tile.
1.
Joint Sealant: Multicomponent pourable polysulfide sealant.
2.
Joint-Sealant Color: As selected by Architect from manufacturer's full range.
D.
Joint-Sealant Application JS-4: Interior perimeter joints of exterior openings.
1.
Joint Sealant: ES-3.
E.
Joint-Sealant Application JS-5: Interior ceramic tile expansion, control, contraction, and isolation
joints in horizontal traffic surfaces.
1.
Joint Sealant: ES-3.
2.
Joint-Sealant Color: As noted.
F.
Joint-Sealant Application JS-6: Interior joints between plumbing fixtures and adjoining walls, floors,
and counters.
1.
Joint Sealant: ES-3.
2.
Joint-Sealant Color: White.
G.
Joint-Sealant Application JS-7: Vertical joints on exposed surfaces of interior partitions.
1.
Joint Sealant: ES-3.
H.
Joint-Sealant Application JS-8: Perimeter joints between interior wall surfaces and frames of
interior doors, windows.
1.
Joint Sealant: ES-3.
I.
Joint-Sealant Application JS-9: HVAC joints.
1.
Joint Sealant: ES-2.
2.
Joint-Sealant Color: Aluminum.
J.
Joint-Sealant Application JS-10: Non-porous material to non-porous material.
1.
Joint Sealant: ES-4.
2.
Joint-Sealant Color: Clear.
END OF SECTION 07920

R
C 2011 Starbucks Coffee Company

Starbucks Coffee
Company
2401 Utah Avenue South
Seattle, Washington 98134
(206) 318-1575
These Drawings and Specifications are confidential
and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Rev

Date

Revision Schedule
By
Description

Doors and Windows

SECTION 07842 - FIRE-RESISTIVE JOINT SYSTEMS


1.1
SUMMARY
A.
Fire-resistive joint systems for the following:
SECTION 08110 - STEEL DOORS AND FRAMES
1.
Floor-to-wall joints.
1.1
SUMMARY
2.
Head-of-wall joints.
A.
Standard hollow metal doors and frames.
3.
Wall-to-wall joints.
1.2
SUBMITTALS
1.2
PERFORMANCE REQUIREMENTS
A.
Product Data: For each type of product indicated. Include construction details, material descriptions,
A.
Fire-Resistance Ratings of Joint Systems in and between Fire-Resistance-Rated Constructions:
core descriptions, fire-resistance rating, temperature-rise ratings, and finishes.
Equaling or exceeding the fire-resistance ratings of construction that they join, [and with movement
B.
Shop Drawings: Include the following:
capabilities indicated ]as determined by UL 2079.
1.
Elevations of each door design.
1.3
SUBMITTALS
2.
Details of doors, including vertical and horizontal edge details and metal thicknesses.
A.
Product Data: For each type of product indicated.
3.
Frame details for each frame type, including dimensioned profiles and metal thicknesses.
1.4
QUALITY ASSURANCE
4.
Locations of reinforcement and preparations for hardware.
A.
Fire-Test-Response Characteristics: Tested by [UL] [OPL] <Insert name of qualified testing and
5.
Details of each different wall opening condition.
inspecting agency>.
6.
Details of anchorages, joints, field splices, and connections.
1.5
MATERIALS
7.
Details of accessories.
A.
Products: Subject to compliance with requirements, provide one of the fire-resistive joint systems
8.
Details of moldings, removable stops, and glazing.
indicated for each application in the Fire-Resistive Joint System Schedule.
9.
Details of conduit and preparations for power, signal, and control systems.
B.
Accessories: Forming materials and other components needed to install fill materials.
1.3
QUALITY ASSURANCE
C.
Designation System for Joints in or between Fire-Resistance-Rated Constructions: Alphanumeric
A.
Standard Hollow Metal Quality Standard: ANSI/SDI A250.8.
systems listed in UL's "Fire Resistance Directory" under Product Category XHBN.
B.
Fire-Rated Doors and Frames: [Positive-pressure] [Neutral-pressure] testing.
D.
Floor-to-Wall Fire-Resistive Joint Systems:
1.4
PRODUCTS
1.
UL-Classified Systems: FW-S-0000-0999.
A.
Standard Hollow Metal Doors:
2.
Assembly Rating: As Indicated.
1.
Design: Flush panel.
3.
Nominal Joint Width: As indicated.
2.
Thermal-Rated Doors: Exterior where indicated.
E.
Head-of-Wall Fire-Resistive Joint Systems:
3.
Exterior Doors: Face sheets fabricated from metallic-coated level 2 bullet resistant steel
1.
UL-Classified Systems: HW-D-0000-0999.
sheet.
2.
Assembly Rating: As indicated.
a.
Level 2 and Physical Performance Level B (Heavy Duty).
3.
Nominal Joint Width: As indicated.
B.
Standard Hollow Metal Frames:
4.
Movement Capabilities: Class III - compression or extension.
1.
Exterior Frames: Metallic-coated steel sheet; full profile welded.
F.
Wall-to-Wall Fire-Resistive Joint Systems:
a.
Frames for Level 2 Steel Doors: 0.053-inch-(1.3-mm-) thick steel sheet.
1.
UL-Classified Systems: WW-S-0000-0999.
2.
Interior Frames: Cold-rolled steel sheet; knocked down.
2.
Assembly Rating: As indicated.
a.
Frames for Level 1 Steel Doors: 0.042-inch-(1.0-mm-) thick steel sheet.
3.
Nominal Joint Width: As indicated.
b.
Frames for Wood Doors: [0.042-inch-(1.0-mm-)] thick steel sheet.
END OF SECTION 07842
C.
Hollow Metal Panels: Same materials, construction, and finish as adjoining hollow metal work.
D.
Accessories:
1.
Moldings and stops for glazed lites.
2.
Terminated (hospital) stops.
3.
Louvers: [Sightproof] [Lightproof] [Fire-rated automatic], steel.
E.
Finishes: [Factory priming for field painting] [Factory-applied paint].
1.5
INSTALLATION
A.
Metal-Stud Partitions: Frames filled with insulation.
B.
Concrete and Masonry Walls: Frames filled with grout.
END OF SECTION 08110

719 East Valley Road


Basalt, Colorado 81621
Eagle County

Metals

SECTION 06402 - INTERIOR ARCHITECTURAL WOODWORK


1.1
SUMMARY
A.
Interior standing and running trim.
B.
Flush wood paneling and wainscots.
C.
Melamine cabinets.
D.
Solid-surfacing-material countertops.
E.
Closet and utility shelving.
1.2
QUALITY ASSURANCE
A.
Quality Standard: AWI.
1.3
MATERIALS
A.
Wood Products: Comply with the following:
1.
Hardboard: AHA A135.4.
2.
Medium-Density Fiberboard: ANSI A208.2, Grade MD, made with binder containing no
urea formaldehyde.
3.
Moisture Resistant Medium-Density Fiberboard: ANSI A208.2, Grade MD, MR50, made
with binder containing no urea formaldehyde.
4.
Straw-based Particleboard: ANSI A208.1, Grade M-2, except for density, made with
adhesive containing no urea formaldehyde.
5.
Softwood Plywood: DOC PS 1, Special Exterior A-A, made with adhesive containing no
urea formaldehyde.
6.
Veneer-Faced Panel Products (Hardwood Plywood): HPVA HP-1, made with adhesive
containing no urea formaldehyde.
B.
Adhesives, General: Do not use adhesives that contain urea formaldehyde.
C.
VOC Limits for Installation Adhesives and Glues: Use installation adhesives that comply with the
following limits for VOC content when calculated according to 40 CFR 59, Subpart D (EPA
Method 24):
1.
Wood Glues: 30 g/L.
2.
Contact Adhesive: 250 g/L.
a.
VOC Limits: 80 g/L
D.
Closet and Utility Shelving:
1.
Grade: Economy.
2.
Shelf Material: 3/4-inch(19-mm) thermoset decorative panel with PVC or polyester edge
banding.
3.
Cleats: 3/4-inch(19-mm) panel product.
E.
Shop Finishing:
1.
Grade: Same grade as woodwork.
2.
Extent: All woodwork shop finished.
1.4
INSTALLATION
A.
Scribe and cut millwork to fit adjoining work, refinish cut surfaces, and repair damaged
finish at cuts.
B.
Anchor millwork to anchors or blocking built in or directly attached to substrates.
Secure with countersunk, concealed fasteners and blind nailing as required for
complete installation. Use fine finishing nails or finishing screws for exposed fastening,
countersunk and filled flush with millwork and matching final finish if transparent finish is
indicated.
C.
Cabinets: Install without distortion so doors and drawers fit openings properly and are
accurately aligned. Adjust hardware to center doors and drawers in openings
and to provide unencumbered operation. Complete installation of hardware and
accessory items as indicated.
1.
Install cabinets with no more than 1/8 inch in 96-inch(3 mm in 2400-mm) sag,
bow, or other variation from a straight line.
D.
Countertops: Anchor securely by screwing through corner blocks of base cabinets or other
supports into underside of countertop.
1.
Align adjacent solid-surfacing-material countertops and form seams to comply
with manufacturer's written recommendations using adhesive in color to match
countertop. Carefully dress joints smooth, remove surface scratches, and clean
entire surface.
2.
Install countertops with no more than 1/8 inch in 96-inch(3 mm in 2400-mm) sag,
bow, or other variation from a straight line.
3.
Secure coved backsplashes to tops per manufactures fabrication manual and to
walls with adhesive.
4.
Calk space between backsplash and wall with sealant specified in Division 7
Section "Joint Sealants."
END OF SECTION 06402

Thermal and Moisture Protection (Continued)

Project Address:

SECTION 03542 - HYDRAULIC-CEMENT-BASED UNDERLAYMENT


1.1
SUMMARY
A.
Hydraulic-cement-based underlayment for use below interior floor coverings.
1.2
MATERIALS
A.
Underlayment: Hydraulic-cement-based, polymer-modified, self-leveling product that can be
applied in minimum uniform thickness of 1/4 inch (6 mm) and that can be feathered at edges to
match adjacent floor elevations.
1.
Cement Binder: Portland cement, or other hydraulic or blended hydraulic cement.
B.
Primer: Product of underlayment manufacturer recommended in writing for substrate,
conditions, and application indicated.
1.
Primer shall have a VOC content of 200 g/L or less when calculated according to 40 CFR
59, Subpart D.
END OF SECTION 03542

Thermal and Moisture Protection

Highway 82 & Willits

Wood and Plastics (Continued)

Project Name:

Concrete (Continued)

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

3/4/2013 12:58:51 PM

Sheet Title:

Design Specifications Commercial Interiors


1/4" = 1'-0"

Scale:

Sheet Number:

G-011

3/4/2013 12:58:52 PM

Finishes (Continued)

R
C 2011 Starbucks Coffee Company

Starbucks Coffee
Company
2401 Utah Avenue South
Seattle, Washington 98134
(206) 318-1575
These Drawings and Specifications are confidential
and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Rev

Finishes

Date

Revision Schedule
By
Description

719 East Valley Road


Basalt, Colorado 81621
Eagle County

SECTION 08345 - DOUBLE ACTING SWING DOORS


SECTION 09260 - GYPSUM BOARD
SECTION 08710 - DOOR HARDWARE
SECTION 08211 - FLUSH WOOD DOORS
PART 1 GENERAL
1.1
SUMMARY
1.1
SUMMARY
1.1
SUBMITTALS
SUMMARY
A.
Interior gypsum board.
A.
Commercial door hardware for swinging doors.
A.
Product Data: For each type of door indicated. Include details of core and edge construction and trim1.1
A.
Section Includes:
B.
Tile backing panels.
B.
Other doors to the extent indicated.
for openings.
1.
Solid-core double acting swing doors with plastic laminate faces.
1.2
SUBMITTALS
C.
Cylinders for doors specified in other Sections.
B.
Shop Drawings: Indicate location, size, and hand of each door; elevation of each kind of door;
SUBMITTALS
A.
Product Data: For each type of product indicated.
1.2
SUBMITTALS
construction details not covered in Product Data; location and extent of hardware blocking; and other 1.2
A.
Product Data: For each type of product indicated. Include construction details, material
B.
Samples: For the following products:
A.
Product Data: Include construction and installation details, material descriptions, dimensions of
pertinent data.
descriptions, core descriptions, fire-resistance rating, temperature-rise ratings, and finishes.
1.
Textured Finishes: Manufacturer's standard size for each textured finish indicated and on
individual components and profiles, and finishes.
1.
Indicate dimensions and locations of mortises and holes for hardware.
B.
Shop Drawings: Include the following:
same backing indicated for Work.
1.3
WARRANTY
2.
Indicate dimensions and locations of cutouts.
1.
Elevations of each door design.
1.3
MATERIALS
A.
Warranty Period: One year from date of Substantial Completion, except as follows:
3.
Indicate requirements for veneer matching.
2.
Details of doors, including vertical and horizontal edge details and metal thicknesses.
A.
Interior Gypsum Board:
1.
Manual Closers: 25 years from date of invoice.
4.
Indicate doors to be factory finished and finish requirements.
3.
Frame details for each frame type, including dimensioned profiles and metal thicknesses.
1.
General: Complying with ASTM C 36/C 36M or ASTM C 1396/C 1396M, as applicable to type
2.
Cylindrical Locksets: Two years from date of invoice.
5.
Indicate fire-protection ratings for fire-rated doors.
4.
Locations of reinforcement and preparations for hardware.
of gypsum board indicated and whichever is more stringent.
3.
Sur-Lock Exit Device: Five years from date of invoice.
C.
Warranty: Sample of special warranty.
5.
Details of accessories.
a.
Must be certified as low emitting. Certification must be based upon the California
1.4
MAINTENANCE SERVICE
1.2
QUALITY ASSURANCE
6.
Details of moldings, removable stops, and glazing.
Department of Health Services Standard Practice for The Testing Of Volatile
A.
Full-Maintenance Service: Six months.
A.
Quality Standard: AWI.
1.3
STANDARD DOUBLE ACTING SWING DOORS
1.5
PRODUCTS
Organic Emissions From Various Sources Using Small-Scale Environmental
1.
AWI Quality Certification Labels or an AWI letter of licensing for doors.
A.
General: Provide doors of design indicated, not less than thickness indicated; fabricated with
A.
Cylinders and Keying:
Chambers, including 2004 Addenda or a jurisdictionally recognized standard using
2.
WI-Certified Compliance Certificate for doors and installation.
smooth surfaces, without visible joints or seams on exposed faces unless otherwise indicated.
equivalent testing methodologies and VOC thresholds.
1.
Construction Keying: Construction [master keys] [cores].
B.
Fire-Rated Wood Doors: Positive pressure testing.
2.
Keying System:
Comply with ANSI/SDI A250.8.
2.
Type X:
1.3
DOOR CONSTRUCTION, GENERAL
a.
Grand master key.
1.
Design: As indicated.
a.
Thickness: 5/8 inch(15.9 mm).
A.
Low-Emitting Materials: Made with adhesives and composite wood products that do not contain urea
b.
Locks master keyed or grand master keyed to existing system.
B.
Core Construction: 3/4 exterior grade solid wood core made with adhesives and composite
b.
Long Edges: Tapered.
formaldehyde.
c.
All cylinders keyed alike.
wood products that do not contain urea formaldehyde.
3.
Moisture- and mold-resistant type: With moisture- and mold-resistant core and surfaces.
1.4
VENEERED-FACED DOORS FOR TRANSPARENT FINISH
d.
Keys: Nickel silver.
1.
Vertical Edges for Double-Acting Doors: Round vertical edges with 2-1/8-inch(54-mm)
a.
Core: 5/8 inch(15.9 mm), Type X.
A.
Interior Solid-Core Doors:
1)
Stamping: Permanently inscribe each key with a LockNet key control
radius.
b.
Long Edges: Tapered.
1.
Grade: [Premium, with Grade AA faces] [Premium, with Grade A faces] [Custom (Grade A
number, state code, and include the following notation:
2.
Top and Bottom Edges: Closed with flush or inverted 0.042-inch-(1.0-mm-) thick, end
c.
Mold Resistance: ASTM D 3273, score of 10 as rated according to ASTM D 3274.
faces)] [Economy (Grade B faces)].
a)
Notation: "DO NOT DUPLICATE."
closures or channels of same material as face sheets.
B.
Tile-Backing Panels:
2.
Species: Select white birch.
2)
Quantity: In addition to one extra key blank for each lock, provide the
3.
Tolerances: Comply with SDI 117, "Manufacturing Tolerances for Standard Steel Doors
1.
Glass-Mat, Water-Resistant Backing Board: ASTM C 1178/C 1178M, with manufacturer's
3.
Cut: Rotary cut.
following:
and Frames."
standard edges.
4.
Core: Particleboard.
a)
Cylinder Change Keys: Two.
C.
Interior Doors: Face sheets fabricated from decorative high pressure laminate. Provide doors
a.
Must be certified as low emitting. Certification must be based upon the California
5.
Construction: Five or seven plies, bonded.
b)
Construction Keys: Four.
complying with requirements indicated below by referencing ANSI/SDI A250.8 for level and model
Department of Health Services Standard Practice for The Testing Of Volatile
1.5
PRIMING/FINISHING
c)
Master Keys: Four.
and ANSI/SDI A250.4 for physical performance level:
Organic Emissions From Various Sources Using Small-Scale Environmental
A.
Shop Priming:
d)
Grand Master Keys: two.
1.
Level 1 and Physical Performance Level C (Standard Duty).
Chambers, including 2004 Addenda or a jurisdictionally recognized standard using
1.
Doors for Opaque Finish: One coat of wood primer.
1.6
FIELD QUALITY CONTROL
a.
Width: As indicated on Drawings.
equivalent testing methodologies and VOC thresholds.
2.
Doors for Transparent Finish: Stain and first coat of finish.
A.
Independent Architectural Hardware Consultant: [Owner] [Contractor] engaged to perform
D.
Hardware Reinforcement: Fabricate according to ANSI/SDI A250.6 with reinforcing plates of 18
b.
Core: 5/8 inch(15.9 mm), Type X.
B.
Factory Finishing: All doors.
inspections.
gauge stainless steel..
c.
Mold Resistance: ASTM D 3273, score of 10 as rated according to ASTM D 3274.
C.
Transparent Factory Finishes:
B.
Occupancy Adjustment: Three months.
E.
Fabricate concealed stiffeners and hardware reinforcement from either cold- or hot-rolled steel
2.
Cementitious Backer Units: ANSI A118.9 and ASTM C 1288 or 1325, with manufacturer's
1.
Grade: [Premium] [Custom].
END OF SECTION 08710
sheet.
standard edges.
2.
Finish: [Conversion varnish] [Catalyzed polyurethane] [UV curable coating] <Insert finish
1.4
STOPS AND MOLDINGS
a.
Thickness: [1/4 inch (6.4 mm)] [As indicated].
designation>.
A.
Moldings for Glazed Lites in Doors: Minimum 0.032 inch(0.8 mm) thick.
b.
Mold Resistance: ASTM D 3273, score of 10 as rated according to ASTM D 3274.
3.
Effect: [Open-grain finish] [Filled finish] [Semifilled finish].
B.
Loose Stops for Glazed Lites in Frames: Minimum 0.032 inch(0.8 mm) thick, fabricated from same SECTION 08800 - GLAZING
C.
Trim Accessories:
D.
Opaque Factory Finishes:
1.1
SUMMARY
material as frames in which they are installed.
a.
Interior: Cornerbead.
1.
Grade: [Premium] [Custom].
A.
Glazing required for the following:
STEEL FINISHES
END OF SECTION 09260
2.
Finish: [Conversion varnish] [Catalyzed polyurethane] [UV curable coating] <Insert finish1.5
1.
Windows.
A.
Prime Finish: Apply manufacturer's standard primer immediately after cleaning and pretreating.
designation>.
2.
Doors.
1.
Shop Primer: Manufacturer's standard, fast-curing, lead- and chromate-free primer
END OF SECTION 08211
SECTION 09310 - CERAMIC TILE
3.
Storefront framing.
complying with ANSI/SDI A250.10 acceptance criteria; recommended by primer
1.1
SUMMARY
SUBMITTALS
manufacturer for substrate; compatible with substrate and field-applied coatings despite 1.2
A.
Paver, glazed, and wall tile.
A.
Product Data: For each glass product and glazing material indicated.
SECTION 08331 - OVERHEAD COILING DOORS
prolonged exposure.
B.
Waterproof membrane for thin-set tile installations.
B.
Glazing Schedule: Use same designations indicated on Drawings for glazed openings in preparing
1.1
B.
Factory-Applied Paint Finish: Manufacturer's standard, complying with ANSI/SDI A250.3 for
C.
Metal edge strips installed as part of tile installations.
a schedule listing glass types and thicknesses for each size opening and location.
1.2
SUBMITTALS
performance and acceptance criteria.
1.2
QUALITY ASSURANCE
C.
Product Certificates: Signed by manufacturers of glass and glazing products certifying that products
A.
Product Data: For each type and size of overhead coiling door and accessory. Include the following: 1.6
Color and Gloss: As indicated by manufacturer's designations.
A.
Mockups for each form of construction.
furnished comply with requirements.
B.
Shop Drawings: For each installation and for special components not dimensioned or detailed in
END OF SECTION 08345
1.3
MATERIALS
1.
For solar-control low-e-coated glass, provide documentation demonstrating that
manufacturer's product data. Include plans, elevations, sections, details, and attachments to other
A.
Glazed Wall Tile Trim Shapes: Coved base, bullnose cap.
manufacturer of coated glass is certified by coating manufacturer.
work.
B.
Thresholds: Satin Anodized Aluminum Thresholds and Transition Strips.
D.
Warranties: Special warranties specified in this Section.
SECTION 08410 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS
1.
Detail equipment assemblies and indicate dimensions, weights, loads, required
1.
Bevel edges at 1:2 slope, with lower edge of bevel aligned with or up to 1/16 inch (1.5 mm)
1.3
QUALITY ASSURANCE
1.1
SUMMARY
clearances, method of field assembly, components, and location and size of each field
above adjacent floor surface. Finish bevel to match top surface of threshold. Limit height of
A.
Preconstruction adhesion and compatibility testing.
A.
Exterior and interior storefront framing.
connection.
threshold to 1/2 inch (12.7 mm) or less above adjacent floor surface.
1.4
WARRANTY
B.
Exterior and interior manual-swing entrance doors.
C.
Samples for Initial Selection: Manufacturer's finish charts showing full range of colors and textures
C.
Mortar: Latex-portland cement
A.
Deterioration of Coated Glass: Not less than 10 years.
1.2
PERFORMANCE REQUIREMENTS
available for units with factory-applied finishes.
D.
Elastomeric Sealants: One-part, mildew-resistant silicone.
B.
Deterioration of Insulating Glass: Not less than 10 years.
A.
Delegated Design: Contractor to design aluminum-framed systems.
1.
Include similar Samples of accessories involving color selection.
1.
Sealants shall have a VOC content of [250] <Insert value> g/L or less when calculated
1.5
MATERIALS
B.
Structural Performance:
D.
Samples for Verification: For each type of exposed finish required, prepared on Samples of size
according to 40 CFR 59, Subpart D (EPA Method 24).
A.
Glass Products:
1.
Wind Loads: As indicated on Drawings.
indicated below.
1.4
FLOOR TILE INSTALLATION SCHEDULE
1.
Annealed Float Glass: Clear.
2.
Seismic Loads: As indicated on Drawings.
1.
Curtain Slats: 12 inches(305 mm) long.
A.
Interior Floors on Concrete: Thin-set mortar.
2.
Heat-Treated Float Glass: Heat strengthened.
C.
Deflection of Framing Members:
2.
Bottom Bar: 6 inches(150 mm) long.
1.
Tile Type: Unglazed paver tile.
3.
Coated Float Glass: Sputter coated.
1.
Deflection Normal to Wall Plane: Limited to L/175.
3.
Guides: 6 inches(150 mm) long.
2.
Mortar: Latex- portland cement mortar bond coat.
4.
Insulating Glass: Manufacturer's standard dual-seal units.
2.
Deflection Parallel to Glazing Plane: Limited to L/360 or 1/8 inch(3.2 mm),
4.
Brackets: 6 inches(150 mm) square.
3.
Grout: Polymer-modified unsanded 100% solids epoxy non-sagging grout.
B.
Fire-Resistive Glazing: [Monolithic ceramic glazing material] [Film-faced ceramic glazing material]
whichever is smaller.
5.
Hood: 6 inches(150 mm) square.
B.
Interior Floors on [Waterproof] [Crack-Suppression] Membrane over Concrete and Wood: Thin-set
[Laminated ceramic glazing material] [Specially tempered monolithic glass] [Laminated glass with
D.
Windborne-Debris-Impact-Resistance Performance: <Insert requirement>.
E.
Delegated-Design Submittal: For overhead coiling doors indicated to comply with performance
mortar.
intumescent interlayers] [Gel-filled, dual-glazed units].
1.3
SUBMITTALS
requirements and design criteria, including analysis data signed and sealed by the qualified
1.
Tile Type: Unglazed paver tile.
C.
Silicone Glazing Sealants: [Neutral] [Neutral or basic] [Acid] curing, Class [25] [50] [100/50], VOC
A.
Product Data: Include construction details, material descriptions, dimensions of individual
professional engineer responsible for their preparation.
2.
Mortar: Latex- portland cement mortar bond coat.
less than 250 g/L.
components and profiles, and finishes for each type of product indicated.
1.
Detail fabrication and assembly of seismic restraints.
3.
Grout: Polymer-modified unsanded 100% solids epoxy non-sagging grout.
D.
Glazing Tapes: [Back-bedding-mastic] [Expanded-cellular] type.
B.
Shop Drawings: For aluminum-framed systems. Include plans, elevations, sections, details,
2.
Summary of forces and loads on walls and jambs.
1.5
WALL TILE INSTALLATION SCHEDULE
E.
Glazing Gaskets: [Dense compression] [Soft compression] [Lock strip].
and attachments to other work.
F.
Qualification Data: For qualified Installer.
A.
Interior Walls over Glass-Mat Water-Resistant Backer Board or Cementitious Backer Units: Thin-set
1.6
GLASS UNITS
1.
Include details of provisions for system expansion and contraction and for draining
G.
Seismic Qualification Certificates: For overhead coiling doors, accessories, and components, from
mortar.
1.7
INSULATING-GLASS UNITS
moisture occurring within the system to the exterior.
manufacturer.
1.
Tile Type: [Unglazed ceramic mosaic] [Glazed ceramic mosaic] [Glazed wall] tile.
A.
Solar-Control Low-E Insulating-Glass Units IG-1:
2.
For entrances, include hardware schedule and indicate operating hardware types,
H.
Maintenance Data: For overhead coiling doors to include in maintenance manuals.
2.
Mortar: Latex- portland cement mortar.
1.
Overall Unit Thickness and Thickness of Each Lite: 25 and 6.0 mm.
functions, quantities, and locations.
1.3
PERFORMANCE REQUIREMENTS
3.
Grout: Polymer-modified unsanded grout.
2.
Interspace Content: [Air] [Argon].
C.
Samples: Submit three samples, minimum 2x4, of aluminum finished with system and
A.
Operation-Cycle Requirements: Provide overhead coiling grille components and operators capable
END OF SECTION 09310
3.
Outdoor Lite: Class 1 (clear) float glass.
color proposed for the finished work.
of operating for not less than 50,000 cycles and for 25 cycles per day.
4.
Indoor Lite: Class 1 (clear) float glass.
D.
Warranties: Special warranties specified in this Section.
1.4
DOOR ASSEMBLY
5.
Low-E Coating: Sputtered on second or third surface.
1.4
QUALITY ASSURANCE
A.
General: Fabricate overhead coiling grille curtain consisting of a network of 5/16-inch-(8-mm-)
6.
Visible Light Transmittance: 70 percent minimum.
A.
Quality-control program for structural-sealant-glazed system.
minimum diameter horizontal rods, or rods covered with tube spacers, spaced as indicated.
7.
Winter Nighttime U-Factor: <Insert value> maximum.
B.
Preconstruction sealant testing.
Interconnect rods by vertical links approximately 5/8 inch(16 mm) wide, spaced as indicated and
8.
Summer Daytime U-Factor: <Insert value> maximum.
1.5
WARRANTY
rotating on rods.
9.
Solar Heat Gain Coefficient: <Insert value> maximum.
A.
Materials and Workmanship: Three years.
1.
Space rods at approximately 1-1/2 inches(38 mm) o.c.
10.
Outdoor Visible Reflectance: 11 percent maximum.
B.
Finish: 20 years.
2.
Space links approximately 9 inches(228 mm) apart in a straight in-line pattern.
END OF SECTION 08800
MAINTENANCE SERVICE
3.
Aluminum Grille Curtain: ASTM B 221(ASTM B 221M), alloy and temper recommended by 1.6
A.
Entrance Door Hardware: [Six] <Insert number> months.
aluminum producer and finisher for type of use and finish indicated.
1.7
MANUFACTURERS
B.
Hood: Aluminum.
A.
Basis-of-Design Product: The design for aluminum-framed systems is based on Kawneer
C.
Manual door operator.
Trifab VG 451 front set for exterior applications, Trifab VG 450 for interior applications, and
1.5
INSTALLATION
3500 Series for swing doors. MATERIALS
A.
Factory-authorized representative to [perform startup service and testing] [and] [train Owner's
B.
Aluminum: Alloy and temper recommended by manufacturer.
personnel].
C.
Steel reinforcement.
END OF SECTION 08331
SECTION 09111 - NON-LOAD-BEARING STEEL FRAMING
1.8
FRAMING SYSTEMS
1.1
SUMMARY
A.
Brackets and reinforcements.
A.
Non-load-bearing steel framing members for interior framing systems.
B.
Fasteners and accessories.
1.2
MATERIALS
C.
Concrete and masonry inserts.
A.
Steel Framing for Framed Assemblies:
D.
Concealed Flashing: Manufacturer's standard corrosion-resistant, nonstaining, nonbleeding
B.
Framing Members, General: Comply with ASTM C 754 for conditions indicated.
flashing.
1.
Steel Sheet Components: Comply with ASTM C 645 requirements for metal, unless
E.
Framing system gaskets and sealants.
otherwise indicated.
1.9
GLAZING SYSTEMS
2.
Protective Coating: Coating with equivalent corrosion resistance of
A.
Glazing: As specified in Division 8 Section "Glazing."
ASTM A 653/A 653M, G40 (Z120), hot-dip galvanized, unless otherwise indicated.
B.
Glazing gaskets.
1.3
STEEL FRAMING FOR FRAMED ASSEMBLIES
C.
Spacers and setting blocks.
A.
Salvaged Material: Use salvaged framing materials whenever available.
D.
Bond-breaker tape.
B.
Steel Studs and Runners: ASTM C 645.
E.
Glazing Sealants:
1.
Minimum Base-Metal Thickness: 0.0312 inch(0.79 mm).
1.
Structural sealant.
2.
Depth: As indicated on Drawings.
2.
Weatherseal sealant.
C.
Slip-Type Head Joints: Where indicated, provide one of the following:
1.10
ENTRANCE DOOR SYSTEMS
1.
Single Long-Leg Runner System: ASTM C 645 top runner with 2-inch-(50.8-mm-) deep
A.
Entrance Doors:
flanges in thickness not less than indicated for studs, installed with studs friction fit into
1.
Door Construction: 1-3/4-inch(44.5-mm) overall thickness.
top runner and with continuous bridging located within 12 inches(305 mm) of the top of
2.
Door Design: Medium stile.
studs to provide lateral bracing.
3.
Glazing stops and gaskets.
2.
Double-Runner System: ASTM C 645 top runners, inside runner with 2-inch-(50.8-mm-)
B.
Entrance Door Hardware: Division 8 Section "Door Hardware."
deep flanges in thickness not less than indicated for studs and fastened to studs, and
1.11
ALUMINUM FINISHES
outer runner sized to friction fit inside runner.
A.
Aluminum Finishes: High-performance organic (two coats).
D.
Cold-Rolled Channel Bridging: 0.0538-inch(1.37-mm) bare-steel thickness, with minimum 1/2-inch1.12
SOURCE QUALITY CONTROL
(12.7-mm-) wide flanges.
A.
Testing Agency: [Owner] [Contractor] engaged.
1.
Depth: 1-1/2 inches(38.1 mm).
B.
Structural-Sealant-Glazed Systems: Tested and inspected according to ASTM C 1401
2.
Clip Angle: Not less than 1-1/2 by 1-1/2 inches(38.1 by 38.1 mm), 0.068-inch-(1.73-mm-)
recommendations.
thick, galvanized steel.
1.13
FIELD QUALITY CONTROL
E.
Hat-Shaped, Rigid Furring Channels: ASTM C 645.
A.
Testing: By [Owner-engaged] [Contractor-engaged] agency.
1.
Minimum Base Metal Thickness: As indicated on Drawings [0.0179 inch(0.45 mm)]
END OF SECTION 08410
[0.0312 inch(0.79 mm)] <Insert thickness>.
2.
Depth: As indicated on Drawings.
F.
Cold-Rolled Furring Channels: 0.0538-inch(1.37-mm) bare-steel thickness, with minimum 1/2-inch(12.7-mm-) wide flanges.
1.
Depth: As indicated on Drawings.
2.
Furring Brackets: Adjustable, corrugated-edge type of steel sheet with minimum baresteel thickness of 0.0312 inch(0.79 mm).
3.
Tie Wire: ASTM A 641/A 641M, Class 1 zinc coating, soft temper, 0.0625-inch-(1.59mm-) diameter wire, or double strand of 0.0475-inch-(1.21-mm-) diameter wire.
G.
Z-Shaped Furring: With slotted or nonslotted web, face flange of 1-1/4 inches(31.8 mm), wall
attachment flange of 7/8 inch(22.2 mm), minimum bare-metal thickness of 0.0179 inch(0.45 mm), a
and depth required to fit insulation thickness indicated.
END OF SECTION 09111

Project Address:

Doors and Windows (Continued)

Highway 82 & Willits

Doors and Windows (Continued)

Project Name:

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Doors and Windows (Continued)

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

Sheet Title:

Design Specifications Commercial Interiors


1/4" = 1'-0"

Scale:

Sheet Number:

G-012

3/4/2013 12:58:53 PM

SECTION 09681 - CARPET TILE


1.1
QUALITY ASSURANCE
A.
Products comply with requirements of CRI's Green Label Indoor Air Quality Testing Program.
1.2
WARRANTY
A.
Carpet Tile: one years.
1.3
MATERIALS
A.
Adhesives: Water-resistant, mildew-resistant, nonstaining, pressure-sensitive type to suit products
and subfloor conditions indicated, that complies with flammability requirements for installed carpet
tile and is recommended by carpet tile manufacturer for releasable installation.
a.
VOC Limits: 50 g/L
1.4
INSTALLATION
A.
Installation Method: Glue down with releasable adhesive.
END OF SECTION 09681

SECTION 09920 - EXTERIOR PAINTING


1.1
SUMMARY
A.
Surface preparation and the application of paint systems on exterior substrates.
1.2
SUBMITTALS
A.
Samples for Verification:
1.
For each non-standard latex topcoat color and gloss indicated.
2.
For each type of non-standard paint system and in each color and gloss of topcoat
indicated.
1.3
QUALITY ASSURANCE
A.
Quality Standards: "MPI Approved Products List" and "MPI Architectural Painting Specification
Manual."
B.
Mockups for each color and finish.
1.4
BLOCK FILLERS
A.
Interior/Exterior Latex Block Filler: MPI #4.
1.5
METAL PRIMERS
A.
Acrylic Metal .
1.6
WOOD PRIMERS
A.
Exterior Latex Wood Primer: MPI #6.
B.
Exterior Oil Wood Primer: MPI #7.
1.7
EXTERIOR LATEX PAINTS
A.
Exterior Latex (Satin): MPI #15 (Gloss Level 4).
B.
Exterior Latex (Semigloss): MPI #11 (Gloss Level 5).
1.8
QUICK-DRYING ENAMELS
A.
Quick-Drying Enamel (Semigloss): MPI #81 (Gloss Level 5).
1.9
EXTERIOR PAINTING SCHEDULE
A.
Clay-Masonry Substrates:
1.
Latex System: MPI EXT 4.1A.
B.
CMU Substrates:
1.
Latex System: MPI EXT 4.2A.
C.
Steel Substrates:
1.
Quick-Drying Enamel System: MPI EXT 5.1A.
D.
Galvanized-Metal Substrates:
1.
Latex System: MPI EXT 5.3A.
E.
Factory Primed Metal Substrates:
1.
Latex System: MPI EXT 5.4H.
F.
Wood - New, Unfinished, Siding and Trim:
1.
Latex System: MPI EXT 6.1L.
G.
Wood - Existing, Painted.
1.
Latex System: MPI EXT 6.3L.
H.
Stucco Substrates:
1.
Latex System: MPI EXT 9.1A.
I.
EIFS:
1.
Latex System: MPI EXT 9.2A.
END OF SECTION 09920

SECTION 09720 - WALL COVERINGS


1.1
SUMMARY
A.
Vinyl and woven glass-fiber wall covering.
1.2
MATERIALS
A.
General: Install Starbucks Coffee Company supplied wall covering.
a.
Must be certified as low emitting. Certification must be based upon the California
Department of Health Services Standard Practice for The Testing Of Volatile Organic
Emissions From Various Sources Using Small-Scale Environmental Chambers, including
2004 Addenda or a jurisdictionally recognized standard using equivalent testing
methodologies and VOC thresholds.
B.
Adhesive: Mildew-resistant, nonstaining, strippable adhesive, for use with specific wall covering and SECTION 09931 - WOOD STAINS AND TRANSPARENT FINISHES
substrate application, as recommended in writing by wall-covering manufacturer, and with a VOC
1.1
SUMMARY
content of 50 g/L or less when calculated according to 40 CFR 59, Subpart D (EPA Method 24).
A.
Surface preparation and application of wood finishes on [exterior] [and] [interior] substrates.
1.3
INSTALLATION
1.
Division 09 painting Sections for special-use coatings.
A.
Install strips in same order as cut from roll.
1.2
SUBMITTALS
END OF SECTION 09720
A.
Samples for Verification: For each type of finish system and in each color and gloss of finish

indicated.
1.3
QUALITY ASSURANCE
SECTION 09910 - INTERIOR PAINTING
A.
Quality Standards: "MPI Approved Products List" and "MPI Architectural Painting Specification
1.1
SUMMARY
Manual."
A.
Surface preparation and the application of paint systems on interior substrates.
1.4
GENERAL
1.2
SUBMITTALS
A.
Chemical Components of Field-Applied Interior Paints and Coatings:
A.
Samples for Verification:
1.
VOC Limits:
1.
For each non-standard latex topcoat color and gloss indicated.
a.
Clear Wood Finishes, Varnishes: VOC not more than 350 g/L.
2.
For each type of non-standard paint system and in each color and gloss of topcoat
b.
Shellacs, Clear: VOC not more than 730 g/L.
indicated.
c.
Stains: VOC not more than 250 g/L.
1.3
QUALITY ASSURANCE
d.
Primers, Sealers, and Undercoaters: 200 g/L.
A.
Quality Standards: "MPI Approved Products List" and "MPI Architectural Painting
1.5
PRIMERS AND SEALERS
Specification Manual."
A.
Exterior Oil Wood Primer: MPI #7.
B.
Mockups for each color and finish.
1.6
STAINS
1.4
MANUFACTURERS
A.
Exterior Semitransparent Latex Stain: MPI #13.
A.
Manufacturers: Subject to compliance with requirements, provide products by one of the
B.
Exterior, Solid-Color Latex Stain: MPI #16.
following:
C.
Stain, Semi-Transparent, for Interior Wood: MPI #90.
Product one for RNA only.
1.7
VARNISHES
1.
Sherwin-Williams Company (The).
A.
Interior Varnish (Semigloss): MPI #74,
2.
or approved equal.
B.
Interior Varnish (Gloss): MPI #75, Gloss Level 6, alkyd type.
1.5
GENERAL
1.8
EXTERIOR WOOD-FINISH-SYSTEM SCHEDULE
A.
Chemical Components of Field-Applied Interior Paints and Coatings:
A.
Solid-Color Latex Stain System: MPI EXT 6.3K.
1.
VOC Limits:
1.
Prime Coat If Tannin Bleeding occurs: Exterior oil wood primer.
a.
Flat Paints and Coatings: VOC content of not more than 50 g/L.
2.
Two Stain Coats: Exterior, solid-color latex stain.
b.
Nonflat Paints and Coatings: VOC content of not more than 150 g/L.
B.
Semitransparent Stain System: MPI EXT 6.3D.
c.
Primers, Sealers, and Undercoaters: 200 g/L.
1.
Two Stain Coats: Exterior semitransparent latex stain.
d.
Anticorrosive Coatings: VOC content of not more than 250 g/L.
1.9
INTERIOR WOOD-FINISH-SYSTEM SCHEDULE
1.6
PRIMERS/SEALERS
A.
Semitransparent Stain System: MPI INT 6.3C
A.
Primer Sealer, Interior, Institutional Low Odor/VOC: MPI #149.
1.
Prime Coat: Stain, semi-transparent, matching topcoat.
Product one for RNA only.
2.
Topcoat: Stain, semi-transparent, for interior wood.
1.
Sherwin-Williams Company; Harmony Interior Latex Primer
B.
Polyurethane Varnish System: MPI INT 6.3K.
2.
or approved equal
a.
Two Field-Applied Finish Coats: Interior Varnish [(satin)] [(gloss)].
B.
Wood-Knot Sealer: Sealer recommended in writing by topcoat manufacturer for use in paint
END OF SECTION 09931
systems indicated.
1.7
METAL PRIMERS
A.
Rust-Inhibitive Primer (Water Based): MPI #107.
1.8
LATEX PAINTS
A.
Latex, Interior, Institutional Low Odor/VOC, (Gloss Level 2): MPI #144.
Product one for RNA only.
1.
Sherwin-Williams Company; Harmony Interior Latex
2.
or approved equal
SECTION 10522 - FIRE EXTINGUISHER CABINETS
B.
Latex, Interior, (Gloss Level 2): MPI #44.
1.1
SUBMITTALS
Product one for RNA only.
A.
Product Data: For each type of product indicated. Include construction details, material
1.
Sherwin-Williams Company; Color Accents Interior Latex
descriptions, dimensions of individual components and profiles, and finishes for fire protection
2.
or approved equal
cabinets.
C.
Latex, Interior, High Performance Architectural, Semi-Gloss (Gloss Level 5): MPI #141.
1.
Fire Protection Cabinets: Include roughing-in dimensions, details showing mounting
1.9
INTERIOR PAINTING SCHEDULE
methods, relationships of box and trim to surrounding construction, door hardware,
A.
Steel Substrates:
cabinet type, trim style, and panel style.
1.
Institutional Low-Odor/VOC Latex System: MPI INT 5.1S.
1.2
PRODUCTS
a.
Prime Coat: Rust-inhibitive primer (water based).
A.
Security Fire Protection Cabinet:
b.
Intermediate Coat: Institutional low-odor/VOC interior latex matching topcoat.
1.
Type: For fire extinguisher.
c.
Topcoat: Institutional low-odor/VOC interior latex (Gloss Level as indicated in
a.
Basis of Design: The design is based on Larsen's Manufacturing Company;
paint schedule).
Model #SS2409-R1.
B.
Glue-Laminated Beam and Column Substrates:
2.
Construction: [Nonrated] [1-hour fire rated] [2-hour fire rated].
1.
Institutional Low-Odor/VOC Latex System: MPI INT 6.1Q.
3.
Mounting: Recessed.
a.
Prime Coat: Interior latex primer/sealer.
4.
Door Style: Emergency cylinder lock, continuous hinge; and clear vision panel.
b.
Intermediate Coat: Institutional low-odor/VOC interior latex matching topcoat.
5.
Finish: Steel, baked enamel or powder coated.
c.
Topcoat: Institutional low-odor/VOC interior latex (Gloss Level as indicated in
END OF SECTION 10522
paint schedule).
C.
Wood Substrates:
SECTION 10523 - FIRE EXTINGUISHERS
1.
Institutional Low-Odor/VOC Latex System: MPI INT 6.3V.
1.1
SUMMARY
a.
Prime Coat: Interior latex primer/sealer.
A.
Owner-Furnished Material: Hand-carried fire extinguishers.
b.
Intermediate Coat: Institutional low-odor/VOC interior latex matching topcoat.
1.2
QUALITY ASSURANCE
c.
Topcoat: Institutional low-odor/VOC interior latex (Gloss Level as indicated in
A.
Fire Extinguishers: NFPA 10 [and FMG listed].
paint schedule).
1.3
PRODUCTS
D.
Gypsum Board Substrates:
A.
Portable, Hand-Carried Fire Extinguishers:
1.
Institutional Low-Odor/VOC Latex System: MPI INT 9.2M.
1.
Multipurpose dry-chemical type, manufacturer's standard container.
a.
Prime Coat: Interior latex primer/sealer.
B.
Mounting Brackets: Steel with identification lettering.
b.
Intermediate Coat: Institutional low-odor/VOC interior latex matching topcoat.
END OF SECTION 10523
c.
Topcoat: Institutional low-odor/VOC interior latex (Gloss Level as indicated in
paint schedule).
E.
High-Impact Gypsum Board Substrates:
1.
High-Performance Architectural Latex System: MPI INT 9.2B.
a.
Prime Coat: Interior latex primer/sealer.
b.
Intermediate Coat: Institutional low-odor/VOC interior latex matching topcoat.
c.
Topcoat: Institutional low-odor/VOC interior latex (Gloss Level as indicated in
paint schedule).
F.
Plaster Substrates:
1.
Institutional Low-Odor/VOC Latex System: MPI INT 9.2M.
a.
Prime Coat: Interior latex primer/sealer.
b.
Intermediate Coat: Institutional low-odor/VOC interior latex matching topcoat.
c.
Topcoat: Institutional low-odor/VOC interior latex (Gloss Level as indicated in paint
schedule).
G.
Acoustical Ceiling Tile:
1.
Institutional Low-Odor/VOC Latex System: MPI INT 9.2M.
a.
Prime Coat: Interior latex primer/sealer.
b.
Topcoat: Institutional low-odor/VOC interior latex (Gloss Level as indicated in paint
schedule).
END OF SECTION 09910

R
C 2011 Starbucks Coffee Company

Starbucks Coffee
Company
2401 Utah Avenue South
Seattle, Washington 98134
(206) 318-1575
These Drawings and Specifications are confidential
and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Rev

Specialties

Date

Revision Schedule
By
Description

719 East Valley Road


Basalt, Colorado 81621
Eagle County

SECTION 09547 - LINEAR METAL CEILINGS


1.1
COMPONENTS
A.
Moldings and trim.
B.
Seismic struts.
C.
Hold-down clips.
D.
Aluminum Pans and Suspension System:
1.
Products: Subject to compliance with requirements:
a.
Bestworth Rommel; Alpolic ACM Panels.
2.
Classification: Unperforated.
3.
Linear Module Width: [2 inches(51 mm)] [4 inches(102 mm)] [6 inches(152 mm)] [8
inches(203 mm)] <Insert dimensions>.
4.
Pan Depth: [5/8 inch(16 mm)] [3/4 inch(19 mm)] [1 to 1-1/2 inches(25 to 38 mm)]
<Insert depth>.
5.
Pan Face Finish: [Mill] [Lacquered mill] [Clear anodized] [Clear mirror-anodized]
[Painted] [Fluoropolymer coated] [Bright reflective] <Insert finish>.
6.
Filler strip.
7.
Suspension-System Main-Carrier Material: Aluminum.
END OF SECTION 09547

SECTION 09640 - WOOD FLOORING


1.1
SUMMARY
A.
[Factory-] [Field-]finished wood flooring.
1.
Solid wood, [strip] [and] [plank].
2.
Engineered wood, [strip] [and] [plank].
3.
[Solid] [Engineered]-wood parquet.
1.2
QUALITY ASSURANCE
A.
Quality Standard: [NOFMA's "Official Flooring Grading Rules."] [MFMA grading rules.] [WCLIB
No. 17 grading rules.]
B.
Mockups for each form of construction and finish.
1.3
MATERIALS
A.
Wood Flooring:
1.
Field-Applied Finish: Water-based urethane finish system.
a.
VOC Content: When calculated according to 40 CFR 59, Subpart D (EPA Method
24), as follows:
1)
Finish Coats and Floor Sealers: Not more than 350 g/L.
2)
Stains: Not more than 250 g/L.
B.
Accessories:
1.
Wood Flooring Adhesive: VOC limits: 100 g/L.
END OF SECTION 09640

Project Address:

SECTION 09510 - ACOUSTICAL PANEL CEILINGS


1.1
SUMMARY
A.
Acoustical panels and exposed suspension systems.
1.2
SUBMITTALS
A.
Product Data: For each type of product indicated.
B.
Coordination Drawings: Reflected ceiling plans, drawn to scale, on which the following items are
shown and coordinated with each other, based on input from installers of the items involved:
1.
Ceiling suspension system members.
2.
Method of attaching hangers to building structure.
3.
Ceiling-mounted items including lighting fixtures, diffusers, grilles, speakers, sprinklers,
access panels, and special moldings.
C.
Samples for Verification: For each component indicated and for each exposed finish required,
prepared on Samples of size indicated below.
1.
Acoustical Panel: Set of full-size Samples of each type, color, pattern, and texture.
2.
Exposed Suspension System Members, Moldings, and Trim: Set of 12-inch-(300-mm-)
long Samples of each type, finish, and color.
D.
Qualification Data: For testing agency.
E.
Field quality-control test reports.
F.
Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified
testing agency, for each acoustical panel ceiling.
G.
Maintenance Data: For finishes to include in maintenance manuals.
1.3
QUALITY ASSURANCE
A.
Acoustical Panel Quality Standard: ASTM E 1264.
B.
Metal Suspension System Quality Standard: ASTM C 635.
1.4
MATERIALS
A.
Acoustical Ceiling Panels General: Must be certified as low emitting. Certification must be based
upon the California Department of Health Services Standard Practice for The Testing Of Volatile
Organic Emissions From Various Sources Using Small-Scale Environmental
Chambers, including 2004 Addenda or a jurisdictionally recognized standard using equivalent testing
methodologies and VOC thresholds.
B.
Acoustical Ceiling Panels T001
1.
Classification: Type IV, mineral base with membrane-faced overlay; Form 2, water felted;
with vinyl overlay on face; Pattern G (smooth).
2.
Color: As indicated on Drawings.
3.
Thickness: 5/8 inch(15 mm).
4.
Modular Size: 24 by 48 inches(610 by 1220 mm).
5.
Broad Spectrum Antimicrobial Fungicide and Bactericide Treatment: Provide acoustical
tiles treated with manufacturer's standard antimicrobial formulation that inhibits fungus,
mold, mildew, and gram-positive and gram-negative bacteria and showing no mold, mildew,
or bacterial growth when tested according to ASTM D 3273 and evaluated according to
ASTM D 3274 or ASTM G 21.
C.
Acoustical Ceiling Panels T003, T004, T005, T006:
1.
Classification: Type III, mineral base with painted finish; Form 2, water felted; Pattern E
(lightly textured).
2.
Color: As indicated on Drawings.
3.
Thickness: 5/8 inch(15 mm).
4.
Modular Size: 24 by 48 inches(610 by 1220 mm).
5.
Broad Spectrum Antimicrobial Fungicide and Bactericide Treatment: Provide acoustical
tiles treated with manufacturer's standard antimicrobial formulation that inhibits fungus,
mold, mildew, and gram-positive and gram-negative bacteria and showing no mold, mildew,
or bacterial growth when tested according to ASTM D 3273 and evaluated according to
ASTM D 3274 or ASTM G 21.
D.
Acoustical Ceiling Panels T211, T212:
1.
Classification: Type III, mineral base with painted finish; Form 2, water felted; Pattern CE
(perforated, small holes and lightly textured).
2.
Color: As indicated on Drawings.
3.
Thickness: 3/4 inch(15 mm).
4.
Modular Size: 24 by 48 inches(610 by 1220 mm).
5.
Broad Spectrum Antimicrobial Fungicide and Bactericide Treatment: Provide acoustical
tiles treated with manufacturer's standard antimicrobial formulation that inhibits fungus,
mold, mildew, and gram-positive and gram-negative bacteria and showing no mold, mildew,
or bacterial growth when tested according to ASTM D 3273 and evaluated according to
ASTM D 3274 or ASTM G 21.
E.
Metal Suspension Systems:
1.
Wide-Face, Capped, Double-Web Steel: Intermediate duty.
F.
Metal Edge Moldings and Trim: Roll-formed sheet metal.
1.5
INSTALLATION
A.
Installation: [ASTM C 636] [UBC Standard 25-2].
1.6
FIELD QUALITY CONTROL
A.
Testing: By [Owner] [Contractor]-engaged agency to test acoustical panel ceiling hanger
fasteners.
END OF SECTION 09511

Finishes (Continued)

Highway 82 & Willits

Finishes (Continued)

Project Name:

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Finishes (Continued)

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

Sheet Title:

Design Specifications Commercial Interiors


1/4" = 1'-0"

Scale:

Sheet Number:

G-013

Architectural Site Plan Notes


A. Refer to Exterior Elevations for building Signage location and
Design ID. Refer to Electrical Plans for electrical requirements.
B. Landscaping to be provided per zoning code and LEED
requirements.
C. Drive-Thru Equipment including vehicle detection loop,
wireless communication, and monitors coordinated by
Starbucks Construction Manager. Refer to Electrical
Specifications for electrical requirements.

E. All parking and drive-thru striping to be provided by landlord.

Starbucks Coffee
Company

F. Trash enclosure to be lockable using steel gates or chain to


be provided by landlord.

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

8
A-202

G. Landlord to provide 6" (150mm) thick concrete paving the


length of the drive-thru lane, extent to include drive-thru window
standing pad.

1
10

H. General Contractor to apply concrete sealer to all exterior


concrete patio and walkway surfaces.
2
'20

0"

.
typ

Sheet Notes
1. 5-Panel Menu board and speaker located at car 5. See
details 3, 6, 8, 9 & 10/A-102.

2. Pre-Menu board located at car 6. See details 1, 2 & 8/A-102.


2

A-201

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

3. Gateway clearance bar. See details 4, 5 & 7/A-102.

5
A-103

Architect of Record

4. Not used.

2
2
A-201

C 2011 Starbucks Coffee Company

D. Landlord is responsible for providing site work, including new


bollards, footing and conduit for drive-thru signage. Coordinate
with Starbucks Construction Manager.

3' - 0"

11305

5. Not used.

1
6. Thank You / Do Not Enter directional sign. See details
2 & 4/A-103.

NEW STARBUCKS COFFEE

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

7. Provide drive-thru shelf at drive-thru window. See details 5, 7


& 8/A-103.
8. New outdoor furniture. See FF&E sheet I-114.
3

Rev Date
2
2/22/12

Revision Schedule
By
Description
HVAC/Sign Revisions

9. Direction of trash enclosure. (Under separate permit)


10. Landlord to provide new bike racks. See details 10/A-103

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

10052

10046
3
A-102

10050

Project Name:

1
A-102

719 East Valley Road


Basalt, Colorado 81621
Eagle County

Project Address:

Highway 82 & Willits

x0018

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

3' - 0"

8' - 0"

EQ. EQ.

10' - 0"
max.

12732 3
5
A-102

Checked by:

11305

3/4/2013 12:57:51 PM

Sheet Title:

Site Plan
Scale:

1" = 10'-0"

5'

10'

20'

Architectural Site Plan


N

Scale: 1" = 10'-0"

As indicated

Scale:

Sheet Number:

A-101

10' - 0" BAR

CLEARANCE BAR

7/8" DIA. x 60"L A307 ANCHOR BOLTS


EMBED 48" MINIMUM (4 EA.)
CLEARANCE
POST PLATE
OUTLINE

4"

5' - 6"

2' - 3"

PRE-SPACED VINYL LETTERING


APPLIED ON SITE AS NEEDED

3' - 0"
1 1/4"
2"

1' - 0"

9'-6" CLEARANCE

TOP VIEW

6' - 0" MINIMUM

1' - 7"

FINISHED GRADE
5"

2" x 2" STEEL CROSS BAR

INTO NATURAL GRADE OR ENGINEERED FILL

2-7/8" DIA. VERTICAL STEEL POLE

R
C 2011 Starbucks Coffee Company

#3 TIES (10" O.C.)


#4 VERTICALS (4 EA.)

3. THE GROUND MUST NOT BE ALTERED AND MUST BE


WELL DRAINED.

9' - 8" ABOVE GRADE

3' - 6"

3/4" DIAMETER x 24" LONG ANCHOR BOLTS


(F1554 GRADE 36, 4 EACH)

2' - 5 1/4"

9"
FINISHED GRADE

Pre-Order Menu Board


Scale:

1/2" = 1'-0"

Clearance Bar Elevation


Scale:

1/2" = 1'-0"

1' - 1"

#3 TIES, TYP.
@ 12" O.C.

NOTE: G.C. TO VERIFY IF EXIST. FOOTING


CAN BE USED IN LIEU OF NEW FOOTING
(TYP.) @ ALL FOOTINGS

Conduit
Detector loop centered on
speaker post 2" (50mm) below
final grade

Concrete footing

(1) Conduit, route back to


electrical panel

Scale:

1/4" = 1'-0"

3/4" CONDUIT
FOR POWER

POST BOTTOM
PLATE OUTLINE

2' - 0" DIA.

Clearance Bar Plan

4 3/4" CONDUIT BUNDLE

8 1/2"

FINISHED
GRADE

Edge of curb

5 Panel 30 Deg Speaker Post

ELEVATION
8' - 1 1/4"

1/2" = 1'-0"

PLAN

Speaker Post Footing


Scale:

1/2" = 1'-0"

4' - 1"

10"

10"
Camera
Microphone

4' - 1"

Engraved
sign

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:
Speaker

2' - 0 1/4"

Scale:

(2) 1" CONDUIT FOR


AUDIO AND DATA
CABLES

4 3/4"

1' - 10"

Outline of
speaker/camera post

x0018
Bollard, see
detail 9/A-103

1/2" DIA. x 12"L ANCHOR BOLTS


EMBED 48" MINIMUM (4 EA.)

6' - 1 1/4"

Edge of
concrete curb

1' - 0"

SPEAKER / CAMERA POST

CONDUIT BUNDLE

6" (150mm) diameter steel bollard


with concrete fill paint to match
speaker/camera post. See detail 9/A-103

2' - 6"

Concrete footing

1/2" = 1'-0"

2' - 0"

4' - 0"

5' - 4"

Outline of menu
board above

Scale:

2' - 0" MIN. INTO NATURAL GRADE


OR ENGINEERED FILL

Menu panel pivot


minimum clear
distance

Menuboard & Pre-Menuboard Footing

4' - 0"

(1) Conduit, route to data rack


(1) Conduit, route to drive thru window
(1) Conduit, route to electrical panel

Clearance bar,
see detail 4/A-102
12732

Minimum Clearance

30

1' - 0"

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt


3/4/2013 12:57:53 PM

5' - 1"

3/4" CONDUIT FOR


120V AC (CENTER
IN FOOTING)

#5 VERTICALS
(6 EACH)

DIAMETER

4' - 6"

Revision Schedule
By
Description

PLAN

2' - 0"

Date

719 East Valley Road


Basalt, Colorado 81621
Eagle County

1/2" = 1'-0"

SIDE ELEVATION

Rev

Project Address:

FRONT ELEVATION

#3 TIES (3 EACH)

Highway 82 & Willits

PLATE DETAIL

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Project Name:

20'-0" (6m) to centerline of


Order confirmation post

MENU BOTTOM
PLATE OUTLINE

4"

2' - 2"

FINISHED GRADE

THIS DETAIL IS FOR


REFERENCE ONLY.
SIGNAGE SUPPLIED AND
INSTALLED BY OTHERS
UNDER SEPARATE PERMIT.

GRADE OR ENGINEERED FILL

2' - 0"

MOUNTING PLATE

Pre-Menu 30 Deg
Scale:

1/2" = 1'-0"

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

4' - 3" MIN. INTO NATURAL

Scale:

FREE-STANDING MENU
(DESIGN VARIES)

2' - 1 3/4"
Edge of
concrete curb

Clearance Bar Footing

DECOR PANEL

8 3/4"

3' - 0"

4' - 6"

Concrete footing
see additional
details for
construction

Minimum Clearance

Outline of menu
board above

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

2. CONCRETE RESISTANCE 3600 PSI AFTER 28 DAYS.

4. EXPECTED GROUND BEARING CAPACITY AT 3000 PSF.

1 1/2"

30

10' - 6" POLE

2"

(1) Conduit route back to


electrical panel

4' - 1"

Menu panel pivot


minimum Clear distance

Starbucks Coffee
Company

PLAN

NOTES:
1. FOOTING DEPTH MAY VARY AS PER SITE AND SOIL
CONDITIONS.

1' - 0" DIA.

SPLIT FRAME

5"

Sheet Title:

Site Details
2' - 2"
Front elevation

Finished grade

Side elevation
As indicated

Scale:

Menu 5 Panel Free Standing


Scale:

1/2" = 1'-0"

10

Drive Thru Speaker/Camera Post


Scale:

1/2" = 1'-0"

Sheet Number:

A-102

2
2

THANK
YOU

DO NOT
ENTER

SIDE A

SIDE B

THIS DETAIL IS FOR


REFERENCE ONLY. SIGNAGE
SUPPLIED AND INSTALLED BY
OTHERS UNDER SEPARATE
PERMIT.

ACRYLIC GRAPHIC PANELS

2' - 0" MIN. INTO NATURAL GRADE


OR ENGINEERED FILL

SEE SITE PLAN FOR ORIENTATION


OF GRAPHIC PANELS TO SITE.

2' - 1"

3/4" DIA. 12" LONG


ANCHOR BOLTS;
EMBED 6" MINIMUM
(2 EA. SIDE)

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

6"
#3 TIES, TYP.
#4 VERTICALS (4 EA.)
1' - 6" DIA.

FRONT ELEVATION

Illuminated Two-Sided Sign #2


Scale:

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

FINISHED GRADE

FINISHED
GRADE

Starbucks Coffee
Company

1/2" CONDUIT FOR


120 VAC (CENTER IN
FOOTING)

#3 TIES (3 EA.)

SIDE ELEVATION

C 2011 Starbucks Coffee Company

DIRECTIONAL
PLATE OUTLINE

1"

SIGN
GRAPHIC

DIRECTIONAL SIGN

3' - 7"

3' - 10"

ALIGN THIS EDGE


PERPENDICULAR
TO CURB

1' - 0"

10"

6"

Directional Sign Footing (Typical)

1/2" = 1'-0"

PLAN

Scale:

1/2" = 1'-0"

Architect of Record

Air curtain and heater


side filters (included)
Bollard

Concrete infill
full length
of drive thru lane

Single panel drive-thru


window assembly
per plan

Rev Date
2
2/22/12

Attach shelf to building


exterior flush to top of
rough opening, centered
on window

4' - 11 1/2"

Window
per plan

3' - 11 1/2"
EQ

EQ

2"

1 3/4"

Stainless Steel shelf


12" (300mm) Minimum
------------------------14" (355mm) Maximum
Interior finish grade
3' - 6"

Bollard

3' - 0"

Drive Thru Window


Scale:

1/2" = 1'-0"

Drive Thru Shelf


Scale:

1 1/2" = 1'-0"

6"
SMOOTH CURVED SURFACE

Hoop rack

Existing concrete

6" DIA. CONCRETE FILLED STEEL


TUBING; PAINT PMS-369

Non-shrink epoxy grout


FINISHED GRADE

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

Sheet Title:

3"

3/4/2013 12:57:55 PM

719 East Valley Road


Basalt, Colorado 81621
Eagle County

3/4" = 1'-0"

Project Address:

Scale:

Project Name:

1/4" = 1'-0"

Drive Thru Window

MIN.

Scale:

33" - 36"

Drive Thru Window No-Bump

6"

Highway 82 & Willits

Exterior finish grade


Elevation

4' - 0"

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Stainless steel shelf

Stainless steel
angle to cap interior
wall. Hem bottom edge

Hold

Existing or new
exterior wall
system

Revision Schedule
By
Description
HVAC/Sign Revisions

Align

3' - 0" AFF

Drive thru window


(typical by landlord)

Detector loop centered on


window 2" (50mm) below
final grade

Centerline
bump-out

Plan

Concrete
curb

3' - 6" +/- 2" (50mm)

12" (300mm) Minimum


------------14" (355mm) Maximum

6"

Window per plan

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Site Details
Core holes no less than 3"
diameter (4" recommended)
As indicated

Scale:

Bollard Detail
Scale:

1/2" = 1'-0"

10

Bike Rack
Scale:

1 1/2" = 1'-0"

Sheet Number:

A-103

Exterior Elevation Notes


A. General Contractor to coordinate and schedule signage
installation with the Signage Contractor providing a minimum
scheduling notice of 4 weeks and 1 week prior to scheduled
date of installation. Starbucks Construction Manager to
provide General Contractor with Signage Contractor contact
information.
B. General Contractor shall coordinate with Electrical
Contractor to furnish and install electrical circuits including all
conduit, wire, connections, and breaker at panel board
necessary to serve Signage.

x0002 typ.

R
C 2011 Starbucks Coffee Company

2' - 7"

C. General Contractor to provide fire treated wood stud


blocking, or equivalent to support Signage.

Starbucks Coffee
Company

2' - 4"

D. Signage Contractor shall verify size and location of any


and all allowable monument or pole signage with landlord and
provide shop drawing(s) prior to fabrication to Starbucks
Designer for approval.
11392

E. Signage Contractor to install signage in compliance with


local codes and obtain permit and landlord approval.
F. Signage Contractor to supply shop drawings to Starbucks
Construction Manager and to the General Contractor as
needed. General Contractor to notify Starbucks Construction
Manager immediately if shop drawings or installation is in
discrepancy with Starbucks architectural drawings.

13163
4

G. General Contractor to clean, patch and repair existing


exterior as required.
(4) x0003

EQ. EQ.

Sheet Notes

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575
These Drawings and Specifications are confidential
and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

11392

Architect of Record

1. Provide 3" (75mm) high black acrylic store address on


glazing.

2. GC to apply blackout opaque window film to block view of


new furred wall construction at mop sink. See Wall Finish
plan and schedules for more information.
5209 Lake Washington Blvd NE, Suite 200
Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

3. New drive-thru window shelf per schedule.


4. New 48" Logo sign centered on wall.

Rev

Revision Schedule
By
Description

Date

13157

West Elevation
Scale:

1/4" = 1'-0"

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

10020 3

719 East Valley Road


Basalt, Colorado 81621
Eagle County

Project Name:

Project Address:

13163

Highway 82 & Willits

2' - 4"

2' - 7"

x0002 typ.

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

3/4/2013 12:57:59 PM

Sheet Title:

Exterior Elevations
2

East Elevation
Scale:

1/4" = 1'-0"

Scale:

1/4" = 1'-0"
Sheet Number:

A-201

Exterior Elevation Notes


A. General Contractor to coordinate and schedule signage
installation with the Signage Contractor providing a minimum
scheduling notice of 4 weeks and 1 week prior to scheduled
date of installation. Starbucks Construction Manager to
provide General Contractor with Signage Contractor contact
information.
B. General Contractor shall coordinate with Electrical
Contractor to furnish and install electrical circuits including all
conduit, wire, connections, and breaker at panel board
necessary to serve Signage.

V.I.F.

11392

E. Signage Contractor to install signage in compliance with


local codes and obtain permit and landlord approval.

F. Signage Contractor to supply shop drawings to Starbucks


Construction Manager and to the General Contractor as
needed. General Contractor to notify Starbucks Construction
Manager immediately if shop drawings or installation is in
discrepancy with Starbucks architectural drawings.

1' - 11 1/4"
V.I.F.

13163

Starbucks Coffee
Company

D. Signage Contractor shall verify size and location of any


and all allowable monument or pole signage with landlord and
provide shop drawing(s) prior to fabrication to Starbucks
Designer for approval.

13163

C 2011 Starbucks Coffee Company

C. General Contractor to provide fire treated wood stud


blocking, or equivalent to support Signage.

x0002 typ.
x0002
typ.

G. General Contractor to clean, patch and repair existing


exterior as required.

Sheet Notes
x0003

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575
These Drawings and Specifications are confidential
and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

1. GC to apply blackout opaque window film to block view of


new furred wall construction at mop sink. See Wall Finish plan
and schedules for more information.
2. New drive-thru window shelf per schedule.
3. New 48" Logo sign centered on wall.

4. GC to demo existing storefront window and portion of wall


below. GC to provide new storefront door to match existing
system. GC to install new door and repair all existing adjacent
finishes (match existing) to like new condition as necessary.

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Rev

Revision Schedule
By
Description

Date

5. Verify dimensions that allow for equal light distribution


across Starbucks lettering.

10020 2
4

North Elevation

Project Address:

719 East Valley Road


Basalt, Colorado 81621
Eagle County

1/4" = 1'-0"

Highway 82 & Willits

Scale:

Project Name:

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

3/4/2013 12:58:02 PM

Sheet Title:

Exterior Elevations
1/4" = 1'-0"

Scale:

Sheet Number:

A-202

FRAME DEPTH + 1/2" VERIFY

CUT PENETRATION
FLASHING AND FOLD
THROUGH ROUGH
OPENING, MINIMUM 2"

NOTE: VIEW OF WINDOW FROM INTERIOR


VERIFY HEIGHT OF BACK DAM
WITH WINDOW MANUFACTURER
AND INTERIOR TRIM, 3/4" MINIMUM
BACK DAM

9"

2"

STOREFRONT & UNFLANGED DOORS

24 GAUGE SHEET METAL SILL


PAN, FULLY SOLDERED, SET
PAN IN FULL BED OF SEALANT,
DO NOT PENETRATE
HORIZONTAL SURFACES WITH
FASTENERS

INSTALL 3/8" WIDE


SEALANT JOINT (MINIMUM)
WITH BACKER
ROD AROUND INTERIOR
PERIMETER OF
STOREFRONT SLEEVE AT
HEAD, JAMBS, AND SILL

Starbucks Coffee
Company
2401 Utah Avenue South
Seattle, Washington 98134
(206) 318-1575

18
"

AT SILL, INSTALL
SEALANT JOINT BETWEEN
BACKDAM OF SILL PAN
AND WINDOW

Typ. Window Pan (Sheet Metal)


Scale:

1" = 1'-0"

Step H: Interior Sealant Joint


Scale:

3/8" = 1'-0"

Step D: Jamb Penetration Flashing


Scale:

3/8" = 1'-0"

Penetration Wrap Notes


Scale:

3/8" = 1'-0"

COORDINATE HEIGHT OF
BACK DAM WITH THRESHOLD
AND JAMB AT DOORS, NO
ATTACHMENTS THROUGH
HORIZONTAL SILL PAN

6"

6"

ATTACH PENETRATION
FLASHING TO ROUGH
OPENING AT INTERIOR
FACE OF FRAMING

CUT PENETRATION
FLASHING AND
FOLD THROUGH
ROUGH OPENING,
MINIMUM 2"

FRAME DEPTH + 1/2" VERIFY

INSTALL 24 GA HEAD
FLASHING, SEE
DETAILS FOR TYPICAL
FLASHING DETAILS

FACTORY FORMED
CORNER BOOTS

9"
9"

9"

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

2"

Rev

9"
9"

10

1" = 1'-0"

Step J: Head Flashing


Scale:

3/8" = 1'-0"

Step E: Head Corner Boots


Scale:

3/8" = 1'-0"

2"

Step A: Sill Penetration Flashing


Scale:

3/8" = 1'-0"

FLASHING

LAP WEATHER RESISTIVE


BARRIER FROM ABOVE
OVER HEAD AND JAMB
FLASHING, HORIZONTAL
LAPS TO BE 6" MINIMUM,
VERTICAL LAPS TO BE
12" MINIMUM .
TAPE ALL SEAMS WITH
MANUFACTURER
APPROVED AIR BARRIER
TAPE.

Flashing Detail @ Jamb


Scale:

1 1/2" = 1'-0"

9"
MI
N

9"

NOTE: SEAL OVER HEADS OF


ALL PERIMETER OPENINGS.

18"

NOTE: SEALANT ON BACK LEG


OF FLASHING TO BE APPLIED
PRIOR TO INSTALLATION OF
FRAME.

15

9"

9"

9"

2"

11

Step K: Weather Resistive Barrier


Scale:

3/8" = 1'-0"

Step F: Head Penetration Flashing


Scale:

3/8" = 1'-0"

MI
N

Step B: Sill Corner Boots


Scale:

3/8" = 1'-0"

FULLY SOLDERED END DAM


* SEE DETAILS 13 AND 14
FOR TYPICAL PANS

24 GAUGE SHEET METAL


HEAD FLASHING WITH 7
DEGREE SLOPE
6"
1/2"
HEMMED DRIP
EDGE, TYPICAL
1/4"

AD H
HE EPT
D /8"
+1

1"
UNBROKEN FOLDED END DAM
24 GAUGE SHEET METAL
HEAD FLASHING WITH 7
DEGREE SLOPE
6"
HEMMED DRIP
EDGE, TYPICAL

1/4"

12

Typ. Head Flashing


Scale:

3/4" = 1'-0"

AD H
HE EPT
D /8"
+1
1"

SHEET METAL SILL PANS, DO


NOT PENETRATE PANS WITH
FASTENERS

INSTALL STOREFRONT PER


MANUFACTURER'S SPECIFICATIONS,
IF WINDOW INSTALLATION DIFFERS
FROM MANUFACTURER'S
INSTALLATION INSTRUCTIONS,
NOTIFY ARCHITECT OF
DISCREPANCIES

SOLDERED END DAM

719 East Valley Road


Basalt, Colorado 81621
Eagle County

NOTE: SEAL GLASS POCKET


OF DOOR JAMB AT SILL.

LINTEL

9"

Project Address:

SILL

SHEET ALUM.
END DAM

9"

18"

Highway 82 & Willits

SEALANT

FACTORY FORMED CORNER BOOTS

Project Name:

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt


3/4/2013 12:58:04 PM

Scale:

Revision Schedule
By
Description

12
"

Typ. Storefront & Door Pan (Sheet Metal)

Date

12"

9"
SECURE TO SUBSTRATE, COORDINATE
ATTACHMENTS WITH WATERPROOFING
MEMBRANE MANUFACTURER, SEE DETAILS
FOR LEG CONFIGURATION

Architect of Record

EXTEND
PENETRATION
FLASHING 12"
BEYOND ROUGH
OPENING AT EACH
END OF SILL

SLOPE SILL PAN TO DRAIN


24 GAUGE FULLY SOLDERED SHEET METAL
SILL PAN, SHIM DOOR THRESHOLD OFF PAN
SURFACE TO DRAIN AND SET BACK LEG OF
PAN IN CONTINUOUS SEALANT

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

BUTTERFLY BOTTOM
CORNERS WITH
SELF-ADHESIVE
FLEXIBLE FLASHING.

VERIFY WITH SITE CONDITIONS

3"

14

C 2011 Starbucks Coffee Company

6"

SLOPE SILL PAN TO DRAIN

13

9"

2"

1. WRAP DOOR OPENINGS SIMILAR TO STEPS A THROUGH K.


SEE LANDLORD'S ARCHITECTURAL DRAWINGS FOR HEAD FLASHING
CONFIGURATIONS AND ADDITIONAL DETAILS.
DO NOT PENETRATE SILL PAN WITH FASTENERS.

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

LEED

AP:

Production Designer:
Checked by:
Sheet Title:

1/2"

Flashing Details

FOLDED END DAM

As indicated

Scale:

Step G: Storefront
Scale:

3/8" = 1'-0"

Step C: Sill Pan


Scale:

3/8" = 1'-0"

SET SILL PAN IN


BEAD OF SEALANT
AS SHOWN, SLOPE
PAN TO DRAIN

Sheet Number:

A-600

Exit Separation Notes


Occupancy:

A-2

Total occupants:

65

Exits:
required
provided
Maximum overall diagonal:

2
3

C 2011 Starbucks Coffee Company

Exit separation:
allowed
provided

>25'
26'

Common path of egress:


allowed
provided

<75'
41' - 6"

Exit access travel distance:


allowed
provided

<250'
85' - 7"

ADA Key
1. All thresholds to be ADA compliant per all applicable codes.
2. Barrier-free path of travel.
3. 30" x 48" clear for wheelchair access.
4. 32" minimum clear at restroom door.

75' (1/3 = 25')

5. 60" diameter clear for wheelchair access. See sheet I-402 for
restroom clearances.

Starbucks Coffee
Company
2401 Utah Avenue South
Seattle, Washington 98134
(206) 318-1575
These Drawings and Specifications are confidential
and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

6. POS, condiment cart, and hand-off plane are 2'-10" AFF for
wheelchair accessibility.

7. Provide barrier free signage at ADA restrooms per all


applicable codes.
5209 Lake Washington Blvd NE, Suite 200
Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Electrical & Lighting Key


3

8. 36" clear for electrical panel access.

Rev

Date

Revision Schedule
By
Description

9. 30" X 42" clear for lighting control access.

in.
M
"
36

Ma
xim
um
ove
rall
dia
gon
75'
al

in.
M
"
36

4
5

Code/Accessibility Plan
Scale:

1/4" = 1'-0"

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

2'
Scale: 1/4" = 1'-0"

3/4/2013 12:59:07 PM

719 East Valley Road


Basalt, Colorado 81621
Eagle County

RESTROOM

Project Address:

8
RESTROOM

Highway 82 & Willits

5
4

Project Name:

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

4'

8'

Sheet Title:

Code/Accessibility Plan
1/4" = 1'-0"

Scale:

Sheet Number:

I-101

Wall Type Legend


1

Wall Blocking Key

Existing Wall

New Partition Wall to 6" (152mm) Above Ceiling

5"

20 Ga 3-5/8" (86 mm) metal studs 16"


(406mm) O.C. with 5/8" (16 mm) Type "X"
GWB on one or both sides to minimum of 6"
(152 mm) above ceiling grid. Moisture
resistant gypsum board in restrooms,
workroom, backbar and walls adjacent to
drive-thru casework. Drywall screws @ 12"
(305 mm) O.C., 45 degrees. Metal stud
reinforcement @ 48" (1219 mm) O.C. above
ceiling line to structure above.
3

Existing Wall

New Furred Wall to 6" (152 mm) Above Ceiling

4 1/4"

20 Ga 3-5/8" (86 mm) metal studs 16" (406


mm) O.C. with 5/8" (16 mm) Type "X" GWB
to minimum of 6" (152mm) above ceiling grid.
Moisture resistant gypsum board in
restrooms, workroom, backbar and walls
adjacent to drive-thru casework. Drywall
screws @ 12" (305 mm) O.C., 45 degree
metal stud reinforcement @ 48" (1219 mm)
O.C. above ceiling line to structure above.

7 1/4"

20 Ga 6" (152 mm) metal studs 16" (406


mm) O.C. with 5/8" (16 mm) moisture
resistant gypsum board on both sides to
minimum 6" (152 mm) above ceiling. Secure
moisture resistant gypsum board to studs
with drywall screws at 10" (254 mm) O.C. at
panel edges and 12" (305 mm) O.C. at
intermediate supports. 45 degree metal stud
reinforcement @ 48" (1219 mm) O.C. above
ceiling line to structure above.

ITEM

WEIGHT

HEIGHT AFF

APPROX. WIDTH

WORKROOM HAND SINK

125 LBS

3'-0" TO 3'-4"

2'-6" BEHIND SINK

SHELVES ABOVE 3-COMP SINK

200 LBS

5'-8" TO 6'-0"

8'-0" CENTERED ABOVE 3-COMP SINK

New Plumbing Wall 6" (152mm) Above Ceiling


(Moisture resistant gypsum board
restroom/backer side only)
20 Ga 6" (152 mm) metal studs 16" (406 mm)
O.C. with 5/8" (16 mm) moisture resistant
gypsum board on restroom or casework side to
ceiling and 5/8" (16 mm) Type "X" GWB on
other side to minimum 6" (152 mm) above
ceiling. Secure moisture resistant gypsum
board to studs with drywall screws at 10" (254
mm) O.C. at panel edges and 12" (305 mm)
O.C. at intermediate supports. 45 degree metal
stud reinforcement @ 48" (1219 mm) O.C.
above ceiling line to structure above.

7 1/4"

A. General Contractor to verify all dimensions and notify


Starbucks Construction Manager of any discrepancies prior to
construction. All dimensions to be taken from designated
datum point.

New Plumbing Wall 6" (152mm) Above Ceiling


SYMBOL

Verify existing GWB in areas near moisture is a moisture resistant gypsum wallboard.
Replace as necessary. Secure moisture resistant GWB to studs with drywall screws at 10"
O.C. at panel edges and 12" O.C. at intermediate supports.

Floor Plan Notes

300 LBS

SHELVES AND DATA RACK AT


MANAGERS DESK

1/2" ACX PLYWOOD

7'-0" CENTERED ABOVE


MANAGER'S DESK
AND DATA RACK

B. If existing exterior entrance threshold exceeds required


Americans with Disability Act (ADA) maximum height of 1/2"
(10mm), remove and replace with accessible threshold. Raised
thresholds and floor level changes at accessible doorways to
be beveled with a slope no greater than 1:12.

RESTROOM GRAB BARS

200 LBS

2'-6" TO 3'-0"

5'-0" AROUND WC

C. General Contractor to provide fire treated wood stud


blocking, or equivalent to support any wall attachment and/or
signage.

RESTROOM HAND SINK

200 LBS

3'-0" TO 3'-4"

2'-6" BEHIND SINK

D. All doors to provide 3-6 (900mm) minimum clear opening


when opened to 90 degree position unless otherwise noted.

UPPER STORAGE (CUBBY) CABINETS


AT BACKBAR

BLOCKING SPECIFICATION FOR FRENCH CLEAT MOUNTING SYSTEM


TO BE DETERMINED BY G.C. BASED ON INFORMATION PROVIDED ON
STARBUCKS' AEC WEBSITE.

E. Verify all existing doors, hardware and frames meet


Starbucks and/or code requirements.

DIAPER CHANGING TABLE

250 LBS

F. Install 1/4" (6mm) green board on backbar wall per


specification.

3'-4 1/2" TO 3'- 10 3/4"

2'-10" BEHIND TABLE

Sheet Notes
1

1. GC to verify all existing dimensions prior to construction.


2. Align finished face of wall to existing finish .
3. Existing column.

New Partial Height Wall


4. Existing storefront to remain.
Same as

with height noted on Interior Elevations.


8'

"
-2

R
C 2011 Starbucks Coffee Company

Starbucks Coffee
Company
2401 Utah Avenue South
Seattle, Washington 98134
(206) 318-1575
These Drawings and Specifications are confidential
and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

5. GC to demo existing storefront window and portion of wall


below. GC to provide new storefront door to match existing
system. GC to install new door and repair all existing adjacent
finishes (match existing) to like new condition as necessary.
See flashing details on sheet A-600.

5
6

Architect of Record

1
x0035

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

'10

typ.

4"
1/

Rev

Date

Revision Schedule
By
Description

4
typ.
CAFE
SEATING

1
3
1
BACKBAR

I-507
'22

7
2"
1/

F
6'

"
-6

RETAIL
C

7' - 7 1/4"

Min.
4"

6'

-6

2"
1/

4"

3
6'

1' - 1"

1
-1

2"
1/

2'

"
-0

WORKROOM

5' - 11 1/2"

5"

Project Name:

7' - 7 1/2"

3
2'

2"
1/

4"
1/

10190

'13

3'

RESTROOM

4"
1/

RESTROOM
6

VESTIBULE

10190

D
2

1
B

719 East Valley Road


Basalt, Colorado 81621
Eagle County

4' - 5"

Project Address:

7' - 5"

Highway 82 & Willits

11' - 5 1/4"

4'

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Wall Legend - Floor Plan


New Full Height Wall

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

New Partial Height Wall

Floor Plan
Scale:

Existing Wall

1/4" = 1'-0"

3/4/2013 12:59:12 PM

Sheet Title:
Existing Column
0

2'
Scale: 1/4" = 1'-0"

4'

Floor Plan

8'

As indicated

Scale:

Sheet Number:

I-112

Penetration Plan Notes


A. All stub-up dimensions are relative to finished wall locations
(shown as outlines on this plan). Refer to Floor Plan for wall
placement.
B. Floor Sink: Refer to cut sheets for component specifications
and cutout requirements.
C. Waste Line Penetrations: Refer to Plumbing Plans for individual
line specifications.

R
C 2011 Starbucks Coffee Company

D. Stub-up Penetrations: Refer to Plumbing Plans for individual


stub-up specifications.

Starbucks Coffee
Company

E. Toilet Floor Penetration: Refer to cut sheets for stub-up location


relative to finished wall.
F. Penetration to be located on centerline of wall or as required
per conditions.
G. Trenching outline for guideline use only. General Contractor to
coordinate with specific trades and site conditions to determine
actual layout.

Sheet Notes
1. Floor sink. See cutsheets for component specifications and
cutout requirements. Ensure sink is easily accessible for
servicing.

8"

10

10

4"
1/

2. Waste Line Penetrations. See Plumbing sheets for individual


line specifications.
1'

4"
1/

3. Toilet Floor Penetrations. Refer to product cutsheet for stubup location relative to finished wall.

9"
5'

1
-1

4"
1/
1'

-5

Architect of Record

5. Mop Sink. See cutsheets for component specifications and


cutout requirements.

8'

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

4. Penetration to be located on centerline of wall or as required


per conditions.

2"
1/

-6

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

6. Stub-up penetrations for power. See Electrical sheets for


individual conduit specifications.

2"
1/

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

7. Existing column.

Rev

Date

Revision Schedule
By
Description

1'

7"

4"
1/

4'

1
5'

CAFE
SEATING

-4

2"
1/

"
11
10

2"
1/

4"
1/

1'

1
8'

2'
7
2"
1/

-0

-6

2"
1/

2"
1/

3'

2'

6"

1'
2

-5

4"
1/

4
1
5
7

1' - 4 3/4"

WORKROOM
4'

Project Name:

2"

5' - 2 1/2"

8' - 9 1/2"

1' - 0"

Penetration Plan Legend

Penetration Plan
Scale:

Floor Sink

1/4" = 1'-0"

2'

3/4/2013 12:59:15 PM

Scale: 1/4" = 1'-0"

4'

719 East Valley Road


Basalt, Colorado 81621
Eagle County

3'

4"
3/

1' - 3" 2' - 7 1/4"

RESTROOM

Project Address:

1' - 10 1/2"

2' - 1 1/2"

1' - 6" 2' - 4 1/4"

4'

RESTROOM

7"

VESTIBULE

2"
1/

'14

6'

-2

2"

-1

9'

1' - 4 3/4"

7'

4"
1/

Highway 82 & Willits

RETAIL

4"
1/

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

3'

Note: Verify all waste piping penetrations and electrical


stub locations prior to construction.

BACKBAR

4"
3/

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

Floor Penetration

8'

Sheet Title:

Penetration Plan

Plumbing Penetration Area

Electrical Penetration Area

1/4" = 1'-0"

Scale:

Sheet Number:

I-113

FF and E Plan Notes


A. General Contractor to schedule with local refrigeration
Contractor to conduct initial food case start-up and testing. For
approved Contractor, contact vendor.

x0006 25

B. The space is served by the municipal water and sewer


system unless otherwise noted.

2
I-501

C. All equipment and installation will meet National Sanitation


Foundation standards or equivalent.

R
C 2011 Starbucks Coffee Company

D. Equipment units shall contain no exposed threads,


embellishments or overhanging edges that serve as places for
accumulation of dust, dirt and debris.
3
I-501

G. For Plumbing Fixtures, refer to the Plumbing Design Plan.


For Data Device Schedule, refer to the Electrical Design Plan

10042 (2)
12161
12482

Sheet Notes

0"

1. General Contractor to reverse door hinge on under counter


refrigerator to left-hand swing, as shown.

12187 (7)
12722 (7)

OUTDOOR
SEATING

(3) 12321

8. Location for future espresso machine.

11823
11851
12631

13
CAFE
SEATING

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

10267
1

(2) 10075
10153 10527
10215 10874
10267 11003 12808
12694
x0004

12379 (4)

17

RETAIL

13. 30"x48" clear space for accessible seating. Each location


will require accessible signage on the table, signifying priority
given to those with accessibility needs.

BACKBAR
6

14. Condiment cart with community board above. See Interior


Elevations.

10293 2

18

(2) 10014
10024
10028
10029 (4)

10091
10152 10305
10312 (2)
10314 10549
10396 10724
10746
10855 (2)
10856 (4)

15. Custom community table at 36" AFF with custom base. See
detail 1/I-501.

10597
11115

12376 (3)

17. Merchandise Bays, typ. of 2. See detail 5/I-501 for more


information.

19. Manager's desk. See details 3 & 6/I-503.


10110

20. Water heater. See Plumbing sheets.

12407
10501

VESTIBULE
RESTROOM

13

21. Water filtration equipment. See Plumbing sheets.

10075
24
12618

23

10581
10947
10977

23

22 10102
10971

12

10176

23. Refrigerator. See detail 4/I-507 and Electrical sheets for


more information.

20

24. Warming Station. See detail 3/I-505 and Electrical sheets


for more information.

27

WORKROOM
12383

22. Ice Machine. See details 5/I-503 & 4/I-505 and Electrical
and Plumbing sheets for more information.

5
I-401

25. Custom Bench. See detail 2/I-501 and finish schedule for
more information.

10995
10922
10698

26

18

11083 (2)

26. Existing Column.


27. Water heater above. See Interior Elevations and Plumbing
sheets for more information.

10222 10804 13264


10447 10838

11070

11

21

28. New bike racks. GC & CM to locate ideal location for bike
racks. Minimum clearance between bike racks as indicated.
See cutsheet on AEC website for clarification on other
clearances needed. See detail 10/A-103.

10967

Furniture, Fixtures and Equipment Plan


Scale:

1/4" = 1'-0"

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

2'
Scale: 1/4" = 1'-0"

3/4/2013 12:59:29 PM

16. Custom Banquette. Field verify all dimensions. Provide


outlets with black covers on the front inside of each leg. Finish
per schedule. See detail 3/I-501.

10001 10004 10011 10467


10002 10005 10019 10605
10007 10022 10809
10076
10123

19

18. Equipment at backbar and workroom to be installed per


detail sheets I-504, I-505 and I-506. See Electrical and
Plumbing sheets for more info.

10797

RESTROOM

Revision Schedule
By
Description

12. Location for future pre-wash table.


8
I-504

10

10000
10008 (2)

12640

Date

11. Location for future sanitizer.

10820

26

Rev

10. Rolling Cup Caddy. See detail 9/I-504.

10305

x0033

15

12330 (4)

10462 (9)
10416 (9)

10215
10943
10505
12508 (2)

10344

12490 (13)

12282 (16)

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

9. Location for future undercounter fridge.


10672

12145 (2)

7. General Contractor to coordinate newspaper fixture ordering.


Contact Triad Manufacturing by email
(starbuckscs@triadmfg.com) or by phone (314-381-5280
x1111) to arrange shipment of the fixture. Allow (5) day leadtime.

719 East Valley Road


Basalt, Colorado 81621
Eagle County

12241 (2)

Architect of Record

6. See Interior Elevations and sheet I-504 for distribution of cup


dispensers.

6
I-504

14

12335 (2)

5. Electrical panels. See Electrical sheets.

10003 10012 10312


10008 10014 10856
10267 12336
10010 (2)
10029 (2)

10091 10855 (2)


10396

7
I-504

(26) 12149

13298

4. Location of all switching. See Electrical drawings.

10020

(10) 10513

3. Place fire extinguisher in workroom per fire inspector.

Project Address:

12160 (2)

2. Secure lockers to wall.

Highway 82 & Willits

13

13

10075 10182 10874 10149 (2)


10091 10215 10855
10153 10473 11003
10527 12694
12808

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Project Name:

2'

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

F. Each hand washing sink will have a single service towel and
soap dispenser, and all hand sinks to have a combination faucet
or premixing faucet.

x0005 16

10065 (3)
12139 (3)
28

Starbucks Coffee
Company

E. Warming oven(s) shown for permitting purposes. Installation


at store opening to be verified by Starbucks Construction
Representative.

4'

8'

Sheet Title:

FF and E Plan
1/4" = 1'-0"

Scale:

Sheet Number:

I-114

Casework Plan Notes


A. General Contractor to notify Starbucks Construction Manager
immediately if a discrepancy exists between casework shop
drawings, site dimensions, casework plan or actual casework
fixtures. All dimensions to be taken from designated datum point.
B. Starbucks Construction Manager to coordinate and schedule
casework delivery date. General Contractor to confirm
casework delivery date with casework manufacturer 4 weeks
and 1 week prior to scheduled date of delivery.

R
C 2011 Starbucks Coffee Company

C. Starbucks contracts directly with casework vendor to supply


casework listed in casework schedule, unless otherwise noted.

Starbucks Coffee
Company

D. Refer to casework installation manual provided by casework


vendor for complete installation instructions.

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

E. All casework base units shall be set on 1/4" (6mm) nonabsorbent plastic shims provided by casework vendor.
F. See Wall Finish Plan for location, tagging, and finish schedules
of applied wall treatments.
G. Install oven stainless steel countertop and base cabinet with
1/2" (10mm) gap between adjacent countertops.
H. See Reflected Ceiling Plan for casework soffit locations.
7
I-502

Sheet Notes
1. Do not caulk trash rings to countertops.
2. All new casework, cubbies, countertops and tabletops
throughout. Finish per schedule sheet I-602.

12516

x0008
12100

x0012

11957
13646

x0014
11155
12057

x0015

EQ.

x0016
x0017

1
I-501

5
I-501

12096 12080 (2)


12780 12098 (2)
11945 (2)
11957

Workstation Designations
ADD 01-01
ADD 10-01: Removed backsplash.

6
I-502
RETAIL

(2) 12363
13191
(2) 13331

1
I-503
11945
12080

8
x0004
x0001

8. See Casework Detail sheets for standard plumbing and


electrical details for backbar and frontbar workstations.

BACKBAR

(3) 12100

BRW 09-02

12011
(2) 12028
(2) 12043
12050
12473

12367

12854

CBS 01-01: Modified backsplash length.

11915
12080

CON 03-01
11937 12472
12032 11142 (2)

ESP 37-01: Customized countertop.


ESP 27-01: Customized countertop.

(2)

POS 33-01: Customized for corner transition to ADD 10-01


and CBS 01-01.
6

VESTIBULE
RESTROOM

POS 13-01

RESTROOM

RES 03-01: Customized countertops, diewalls, finish panels


and top caps. (Used with ESP 27-01)
WRM 03-01

Project Name:

WORKROOM

Casework Plan Legend

Casework Plan
Scale:

Indicates Chair Rail

1/4" = 1'-0"

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

2'
Scale: 1/4" = 1'-0"

3/4/2013 12:59:30 PM

Revision Schedule
By
Description

719 East Valley Road


Basalt, Colorado 81621
Eagle County

EQ.

Date

7. Wall finish to be FRP at open areas below countertops


except at warming station per note 6. See Interior Elevations.

x0020
12007 (2)

x0021
12034

EQ.

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

x0009

EQ.

Rev

Project Address:

CAFE
SEATING
2

6. Wall tile to extend below countertop to base tile behind


warming station.

x0013

13355
12100

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

5. Existing column.

Highway 82 & Willits

11962
12008
12019
12023

4. Centerline of Community Table width to align with centerline


of storefront door. Centerline of table length to align with
existing column.

12033
12043 12078

12087
11155
11957

5
I-502

Architect of Record

3. POS, Hand-off, Condiment Cart and end cabinet


countertops to be 2'-10" AFF max for wheelchair accessibility.

x0010
x0011

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

4'

Indicates Stainless Steel

8'

Sheet Title:

Casework Plan
1/4" = 1'-0"

Scale:

Sheet Number:

I-115A

Casework Plan Notes


A. General Contractor to notify Starbucks Construction Manager
immediately if a discrepancy exists between casework shop
drawings, site dimensions, casework plan or actual casework
fixtures. All dimensions to be taken from designated datum point.
B. Starbucks Construction Manager to coordinate and schedule
casework delivery date. General Contractor to confirm
casework delivery date with casework manufacturer 4 weeks
and 1 week prior to scheduled date of delivery.

R
C 2011 Starbucks Coffee Company

C. Starbucks contracts directly with casework vendor to supply


casework listed in casework schedule, unless otherwise noted.

Starbucks Coffee
Company

D. Refer to casework installation manual provided by casework


vendor for complete installation instructions.

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

E. All casework base units shall be set on 1/4" (6mm) nonabsorbent plastic shims provided by casework vendor.
F. See Wall Finish Plan for location, tagging, and finish schedules
of applied wall treatments.
G. Install oven stainless steel countertop and base cabinet with
1/2" (10mm) gap between adjacent countertops.
H. See Reflected Ceiling Plan for casework soffit locations.

Sheet Notes
1. All new casework and cubbies throughout. Finish per
schedule sheet I-602.
2. Mount upper cabinets per details 1 & 2/I-502.

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

3. For wall mounted items, see Wall Finish Plan and Interior
Elevations.
4. Existing column.
13391
3'

5. Provide undercabinet task lights and light valance mounted


below upper cubbies. See detail 3/I-502.

0"

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

11902

Rev

x0007

Date

Revision Schedule
By
Description

11902
4
2
I-502

5
(9) 11977
(14) 12845
below
11902
below

(15) 12816

Upper Casework Plan


Scale:

1/4" = 1'-0"

719 East Valley Road


Basalt, Colorado 81621
Eagle County

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

2'
Scale: 1/4" = 1'-0"

3/4/2013 12:59:32 PM

Project Address:

Highway 82 & Willits

(2) 11956

Project Name:

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

BACKBAR

4'

8'

Sheet Title:

Upper Casework Plan


1/4" = 1'-0"

Scale:

Sheet Number:

I-115B

Reflected Ceiling Plan Notes


A. If required by local code, General Contractor to provide
semi-recessed sprinkler heads with polished chrome
escutcheons centered in Acoustical Ceiling Tile. If
pendant heads are required in gypsum soffit over frontbar,
conceal supply piping within soffit. General Contractor to
submit sprinkler layout to Starbucks' Construction
Manager for approval prior to installation.
R

B. General Contractor to provide and locate sprinklers per


local codes. Contact Starbucks Construction Manager if
design intent is affected.

C 2011 Starbucks Coffee Company

C. Where acoustical ceiling meets wall, provide angle


wall molding for reveal. Match ceiling grid color when
applicable.

Starbucks Coffee
Company

D. Leave (10) additional retail ceiling tiles, to match retail


ceiling paint color, above the workroom ceiling at
manager's desk for future use.
13163 (2)

E. Provide grommet at all ceiling penetrations for fixtures


or supports.
F. Heating, Ventilating, and Air Conditioning (HVAC)
shown for design intent only. Contact project manager if
changed.
G. Diffusers and returns at backbar in Acoustical Ceiling
Tile to be centered in tile, painted to match adjacent
finishes, typical.
H. Paint all HVAC ducts, HVAC diffusers, recessed
speakers and light trim rings the same color as ceiling or
soffit. Typical throughout retail portion of store.

8
(9) x0002

10
J. Paint substitutions are not allowed. Use Starbucks'
national account "color code" when ordering paints. See
Schedule sheets for schedules

11392
x0022
4'

2'

-1

-8

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575
These Drawings and Specifications are confidential
and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

K. See Lighting Design Plan for fixture types and location


dimensions.

"
/4

Sheet Notes

2"
1/

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

2'

1. Under cabinet task light, typ of 10.

2. New hard lid soffit per detail 2/I-507.

2"
1/

x0023
CAFE
SEATING

3. New hard lid soffit to align with centerline of storefront door


and community table below. See detail 3/I-507.

x0022

12946 (5)
15' - 11 1/2"

13

12

typ.

6. Menu boards and daily offering board.


7. Existing Column.

6
EQ.

x0022

8' - 0" AFF

9' - 0" AFF

12859
9. ACT ceiling, see details 6, 7 & 8/I-507.

12

10. Canopy to be provided by landlord.

9'

RETAIL

"
-4

11. See Lighting Plan sheet I-117 for dimensions.

12860
12. Paint soffit elevation same as underside, Bleeker Beige, typ.
1

I-507

Align

I-507

I-507

14

11265 (14)
13245 (14)

typ.

(17) 11533
(17) 13244

11550 (2)

12976

12332
x0024

x0024

12947 (5)

12958 (32)

(11) 12552

VESTIBULE
8' - 0" AFF

RESTROOM
8' - 0" AFF

RESTROOM
WORKROOM

8' - 0" AFF


4

10' - 0" AFF


7

Project Name:

11404 (6)

11154

Reflected Ceiling Plan


Scale:

1/4" = 1'-0"

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

2'
Scale: 1/4" = 1'-0"

3/4/2013 12:59:36 PM

13. Mechanical air supply duct. Paint to match ceiling. See


Mechanical drawings for more information.
14. Mechanical air return duct. Paint to match ceiling. See
Mechanical drawings for more information.

4
x0023

11392

8. Custom light fixture per schedule.

3
13157

BACKBAR

EQ.

6' - 2"

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

5. Speakers to be mounted at maximum height per cutsheet.

(2) 12976
13312
13214

EQ.

719 East Valley Road


Basalt, Colorado 81621
Eagle County

EQ.

Project Address:

Revision Schedule
By
Description
Review Revision

4. Gypsum board ceiling. Paint ceiling and HVAC as noted. See


detail 1/I-509.

10' - 0" AFF


(4) x0003

Rev Date
1
12/4/12

Highway 82 & Willits

5
typ.

4'

8'

Sheet Title:

Reflected Ceiling Plan


1/4" = 1'-0"

Scale:

Sheet Number:

I-116

Lighting Plan Notes


A. All fixtures in work room, back and front line, above
condiment cart, and any other areas where exposed food,
clean equipment or utensils, or unwrapped single service
items will be exposed, shall have shatterproof lamps if the
fixture is not lensed. Architect of Record to include
appropriate lamps / fixtures on drawings and schedules,
and comply with any additional jurisdictional lighting
requirement.
R

B. Provide grommet at all ceiling penetrations for


fixtures/supports.

C 2011 Starbucks Coffee Company

C. Center emergency/exit lights above doors, unless


otherwise noted.

"
-6

x0002 (2)

Sheet Notes

12946
12958

9
4

12946

12946

1. Under cabinet task light, typ of 11.


.
EQ

0"
4' -

-1

"
11

11533 (13)
13244 (13)

5. Exit sign.
5209 Lake Washington Blvd NE, Suite 200
Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

4'

7. Centerline of storefront door.

"
-0

8. Center dimension over 48" Logo sign centerline.


9. Center light over center of Starbucks 14" lettering.

5'

11265 (14)
13245 (14)

Rev

4'

2"
1/

-0

EQ.

6' - 2"
EQ.

"
9'

12332 (3)

11419

-0

0"

"
-4

"

3
1
typ.

3' - 0"

EQ.
4 12947

12958

12947

"

5' - 0"

-0

0"

4'

4'

EQ.

12947

12958

3' - 0"

12958
4'

EQ.

EQ.

3' - 0"

EQ.

EQ.
EQ.

3' - 7 1/2"

EQ.

12947

11533 (2)
13244 (2)
6"

5' - 9 1/4"

12958

"

12946

"
-0

-6

4' - 0"

"

1'

-0

12958
EQ.

3'

1'

5' - 5"

EQ.

0"

11533
13244

8'

12332

4'

4'

4' - 0"

10

-0

11611

12947

4'

4'

12552 (11)

12958

"
-4

11611

11154
EQ.

10
5

EQ.

Project Name:

11611
11404 (6)
6 11419

Lighting Design Plan


1/4" = 1'-0"

719 East Valley Road


Basalt, Colorado 81621
Eagle County

EQ.

Project Address:

EQ.

EQ.

EQ.

"
-8

Highway 82 & Willits

6' - 5 1/2"

"

2'

Scale:

Revision Schedule
By
Description

-1

15' - 11 1/2"

Date

10. Existing Column.

7"

2'

(4) x0003

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

2'
Scale: 1/4" = 1'-0"

3/4/2013 12:59:39 PM

Architect of Record

6. Emergency lighting.

12958

12946 4

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

4. Suspend track at 9-0 AFF. Direct track lights to fully


illuminate merchandise & artwork.
.
EQ

2'

2"
1/

.
EQ

4"
3/

2'

3. Surface-mount track directly to soffit at 9'-0" AFF. Direct


track lights to fully illuminate menu boards.

4"
1/

-8

2"
1/

-0

"

4'

-0

5'

3'

-6

0"

2'

4'

11611 5

2. Suspend bottom of medium pendant lighting fixtures at 6-0


AFF unless otherwise noted. If length of suspended pendant
fixtures exceeds 48" from ceiling, replace with General
Contractor supplied conduit and J-box to dimensioned height.

.
EQ

12958

(5) x0002

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

E. If pendant cylinders can suspended length exceeds


48" (1220mm) from ceiling, replace with surface
mounted cylinder cans and suspend with General
Contractor supplied conduit and J-box to dimensioned
height.

12958

0"
4' 0"
4' -

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

"

2'

(2) x0002

0"
4' -

D. Adjust focus of all track and recessed directional


lighting to fully illuminate all artwork, menu boards, and
merchandise bays.

-9

1' 9"

1'

Starbucks Coffee
Company

4'

8'

Sheet Title:

Lighting Plan
1/4" = 1'-0"

Scale:

Sheet Number:

I-117

Floor Finish Plan Notes


A. Starbucks to supply retail floor tile and tile base. General
Contractor to install. General Contractor to supply workroom tile
and base and install. General Contractor to supply and install
mortar, adhesive, and grout. General Contractor to inspect all
tiles and reject damaged or substandard tiles prior to
installation.
B. All tile and slate to be installed per Tile Council of America
standards.

R
C 2011 Starbucks Coffee Company

C. All flooring and base material to be installed according to


Starbucks specifications.

Starbucks Coffee
Company

D. Cabinet bases to be set after tile installation.


E. Align tile transitions on whole tiles as shown.

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

F. For carpet installation, refer to manufacturers' installation


instructions.

Sheet Notes
1. Floor sink/floor drain location. See Penetration Plan I-113
and Plumbing drawings for more information.
2. Place community table per dimensions. Do not bolt to floor.
3. New polished/sealed concrete floor finish and tile base.
Finish floor per manufacturer's instructions.
4. Existing column.
5. Countertop support leg.

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record
5
typ.

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

x0034

Rev

Date

Revision Schedule
By
Description

3
typ.
1 typ.
CAFE
SEATING

x0034

EQ.

EQ.

EQ.

EQ.

BACKBAR

3
2

I-508
4

RESTROOM

x0034

x0034

WORKROOM
16
I-508

Floor Finish Plan


Scale:

Floor Legend

1/4" = 1'-0"

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:
Wall Base Tile (6" Black)
0

2'
Scale: 1/4" = 1'-0"

3/4/2013 1:00:02 PM

719 East Valley Road


Basalt, Colorado 81621
Eagle County

RESTROOM

Project Address:

x0034
VESTIBULE

Highway 82 & Willits

RETAIL

Project Name:

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

I-508

4'

8'

Wall Base Tile (4" Gloss)


Sheet Title:

Floor Finish Plan

Stained Concrete Floor

1/4" = 1'-0"

Scale:

Sheet Number:

I-118

Wall Finish Plan Notes


A. Workroom to be finished per local code requirements.
B. Install clear corner guards as indicated. Mount at 6
(150mm) AFF. Back-paint with corresponding wall color.
Adhere with clear silicone adhesive and #6 stainless steel oval
head screws 3 (75mm) from ends, 12 (305mm) on center.
Offset screws on either side by 1/2" (10mm) vertically. Cut
corner guards to fit below chair rail at applicable locations. Do
not install corner guards above chair rail.

R
C 2011 Starbucks Coffee Company

C. Install metal corner guards as indicated. Mount at 6


(150mm) AFF. Affix with #6 stainless steel oval head screws 3
(75mm) from ends, 12 (305mm) on center offset screws on
either side by 1/2" (10mm) vertically. To be installed in back of
house only.

Starbucks Coffee
Company

D. Change of paint color allowed at inside corners only.

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

E. Refer to Interior Elevations for graphics locations.


F. Refer to Casework Finish Schedule for additional information

G. General Contractor to provide and install workroom wall


finishes.
5

Sheet Notes

1. Interior walls to receive new paint; see Interior Elevations.


(HC-80 - Benjamin Moore "Bleeker Beige" - Cafe walls)
(HC-140 - Benjamin Moore "Coopley Gray" - Cafe walls)
(HC-80 - Benjamin Moore "Bleeker Beige" - Door frames)

5
8

2. New wall tile at backbar where shown. See Interior Elevations and
details 6, 12, 13, &14/I-508.

I-211
2

3. New FRP at exposed backbar walls. Extend from top of base tile to
bottom of adjacent countertops. Tile backsplash to extend to top of
FRP.
2

4. Wall tile to extend below countertop to base tile behind warming


station.

I-213
8

Architect of Record

5. New community board.

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

6. New artwork. See interior elevations, and refer to manufacturer's


instructions shipped with art.

10
1

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

7. Existing column.

I-211

Rev

Date

Revision Schedule
By
Description

8. Chair rail to continue below window sill at storefront. See Interior


Elevations.

9. Corner guard below chair rail. See detail 4 & 15/I-508. See Interior
Elevations for mounting height.

CAFE
SEATING

9
10. Corner guard at backbar wall. See Interior Elevations

I-213
11. New wall tile in restrooms. See Enlarged Restroom Plan and
Elevations.

10

12. GC to apply blackout opaque window film to block view of new


furred wall construction at mop sink. See schedule for more
information.

3
9
4

13. Full height wall end cap. See finish schedule.

I-212
7

8
4

I-211

RETAIL
8

typ.

I-212
2
3

I-212

I-212

I-212
5

3
1

11

4
RESTROOM

13

8
I-213
13

I-213
I-213

7
I-213

Wall Treatment Key


1

Wall Finish Plan


Scale:

1/4" = 1'-0"

2'
Scale: 1/4" = 1'-0"

3/4/2013 1:00:04 PM

12

I-213

WORKROOM
5

x0019

4'

8'

Indicates chair rail at 36" AFF with


wallpaper below

Indicates backbar wall tile. See


notes 2, 3 and 4 for more information.

Indicates restroom wall tile

Indicates full height FRP

Indicates paint only

719 East Valley Road


Basalt, Colorado 81621
Eagle County

11

Project Address:

RESTROOM

Highway 82 & Willits

1
1

6
1

I-401

VESTIBULE

I-211

Project Name:

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

BACKBAR

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

Sheet Title:

Indicates corner guard

Wall Finish Plan


1/4" = 1'-0"

Scale:

Sheet Number:

I-119

Interior Elevation Notes


A. Refer to manufacturers' instructions shipped with artwork
for installation instructions and spacing.
B. Install wall cabinets before backbar wall tile. Run backbar
wall tile to underside of wall cabinets, not behind cabinets.
4

10017

C. Paint substitutions are not allowed. Use Starbucks'


national account "color code" when ordering paints.

x0023

3
1' - 2 3/4"

typ.

D. Paint finishes shall be applied as follows, unless otherwise


noted;
- All wood and metal surfaces shall be painted
Semigloss, or equal.
- All accent and trim paint to be Semigloss, or equal.
- All wall and ceiling paints to be Eggshell, or equal.

3' - 10"
12332
2

typ.
12693

x0028

1
Vestibule
opening

EQ.

Sheet Notes

10829

1. Chair rail with vinyl wallpaper below. See detail 5, 7 & 10/I-508.

12247

typ.

4' - 10 1/2"

12247 typ.

2. Large pendant light fixture. Bottom of pendant shade at 6'-0"


AFF.
3. Suspended track light fixture at 9'-0" AFF. Aim lights to focus on
merchandise, art or community board.
4. Speakers to be mounted at maximum height per cutsheet.

11403

13331 (2)
11

Cafe - South Wall


Scale:

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

12173
EQ.
5' - 0"

12173 typ.

Starbucks Coffee
Company

E. For Paint and Wall Treatment Schedules, refer to the Wall


Finish Plan. For Graphics Schedule, refer to the Furniture,
Fixtures, and Equipment Plan.

3' - 0"

x0023

C 2011 Starbucks Coffee Company

3/8" = 1'-0"

5. GC to demo existing storefront window and portion of wall


below. Provide new storefront door to match existing system.
Repair all existing adjacent finishes (match existing) to like new
condition as necessary.

Cafe - Seating Area


Scale:

3/8" = 1'-0"

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

6. Community board centered between newstand and vestibule


opening

x0022

EQ.

typ.

EQ.

7. Framed artwork per schedule. Refer to manufacturer's


instructions shipped with art.

11611

11611
5209 Lake Washington Blvd NE, Suite 200
Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

9. Custom top cap. See Casework Plan for more information.

10017 4

10017 4

10. Custom finish panel. See Casework Plan for more


information.

10017
4

11. Merchandise bays. See details 4 & 5/I-501 and 4/I-502

Rev

Date

Revision Schedule
By
Description

12. Custom banquette. See detail 3/I-501.

x0022
typ.
1

12173 typ.

12173 typ.

typ.

3' - 0"

12247 typ.

12247 typ.

5
11403

11403

x0022

typ.

Scale:

3/8" = 1'-0"

x0023

x0023

EQ.

10017
EQ.

EQ.

x0030

EQ.
x0029

7
7

9
x0010

4' - 10 1/2"

Cafe - North Wall (Seating Side)


Scale:

3/8" = 1'-0"

12

typ.

3' - 0"

x0005
12247 typ.

12173

12482

12173 typ.

5' - 9 1/2"

x0022

11611

x0022

12516

Banquette Seating - East wall


Scale:

3/8" = 1'-0"

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

12247

11403

11403

11403

719 East Valley Road


Basalt, Colorado 81621
Eagle County

3/8" = 1'-0"

Cafe - North Wall (Condiment Side)

Project Address:

Scale:

Highway 82 & Willits

Cafe - West Wall

Project Name:

5
3/4/2013 1:00:07 PM

5' - 6"

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

13157

x0011 10

Checked by:

Banquette Seating - South Wall


Scale:

3/8" = 1'-0"

Sheet Title:

Interior Elevations
As indicated

Scale:

Sheet Number:

I-211

Interior Elevation Notes


A. Refer to manufacturers' instructions shipped with artwork
for installation instructions and spacing.
B. Install wall cabinets before backbar wall tile. Run backbar
wall tile to underside of wall cabinets, not behind cabinets.
C. Paint substitutions are not allowed. Use Starbucks'
national account "color code" when ordering paints.

10017
6

D. Paint finishes shall be applied as follows, unless otherwise


noted;
- All wood and metal surfaces shall be painted
Semigloss, or equal.
- All accent and trim paint to be Semigloss, or equal.
- All wall and ceiling paints to be Eggshell, or equal.

4
x0023

x0031

x0023

x0023

x0023

9"

9"

13

11162
x0023
3

12173

12173

12173

x0032

12247

12247

E. For Paint and Wall Treatment Schedules, refer to the Wall


Finish Plan. For Graphics Schedule, refer to the Furniture,
Fixtures, and Equipment Plan.

12173

12173

12247

Sheet Notes
1. Attach menu hinge to top of cabinet to allow access to
cabinet shelves behind, typical.

12247

14

12247
2. Backbar wall tile runs behind warming station.
3. Chair rail with vinyl wallpaper below. See detail 5, 7 & 10/I508.

Cafe / Workroom Wall


Scale:

3/8" = 1'-0"

Cafe / Restroom Wall


Scale:

11403

11403

11403

3/8" = 1'-0"

11403

11403

Vestibule - East Wall


Scale:

Starbucks Coffee
Company
2401 Utah Avenue South
Seattle, Washington 98134
(206) 318-1575

11162
5' - 0"

5' - 0"

C 2011 Starbucks Coffee Company

3/8" = 1'-0"

Vestibule - West Wall


Scale:

3/8" = 1'-0"

Vestibule - South Wall


Scale:

4. Suspended track light fixture at 9'-0" AFF. Aim lights to focus


on merchandise, art or community board.
5. Ceiling mounted track light fixture at backbar. Aim lights to
focus on menu boards.

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

3/8" = 1'-0"
6. Speakers to be mounted at maximum height per cutsheet.

Architect of Record

7. Door finish to match chair rail.


8. Custom countertop. See Casework Plan for more
information.
5209 Lake Washington Blvd NE, Suite 200
Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

9. Custom top cap. See Casework Plan for more information.


10. Custom finish panel. See Casework Plan for more
information.

x0022

11. Custom diewall. See Casework Plan for more information.

Rev

Date

Revision Schedule
By
Description

12. Align top of tile with tile underneath upper cubbies on


backbar wall. Finish with trim per detail 11/I-508.
open to beyond

13. Vertical wood trim. Finish to match chair rail.

open to beyond

11403

11403

x0016 10

Frontbar - Customer Side


Scale:

9
x0015

3/8" = 1'-0"

x0023

x0007

Scale:

3/8" = 1'-0"

5 typ.

12976
13214

12976
13312

12859

12860

x0023

12976

10829

open to beyond

x0027

x0020
x0032
8

14

11403

x0027

Backbar - South Wall


Scale:

3/8" = 1'-0"

x0021

11403

x0012 11

Frontbar - Partner Side

x0023

12

x0017 11

719 East Valley Road


Basalt, Colorado 81621
Eagle County

x0011 10

8
x0014

Project Address:

x0015

Highway 82 & Willits

x0010

Project Name:

7' - 10"

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

14. Hot rolled steel wall end cap. Finish per schedule.
9

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

Backbar
Scale:

3/8" = 1'-0"

3/4/2013 1:00:14 PM

Sheet Title:

Interior Elevations
As indicated

Scale:

Sheet Number:

I-212

12516

x0027

x0027

x0023

x0027

Sheet Notes

Interior Elevation Notes

1. Attach menu hinge to top of cabinet to allow access to cabinet


shelves behind, typical.

A. Refer to manufacturers' instructions shipped with artwork


for installation instructions and spacing.

2. Future sanitizer location.

B. Install wall cabinets before backbar wall tile. Run backbar


wall tile to underside of wall cabinets, not behind cabinets.

3. Custom length countertop. See Casework Plan for more


information.
4. Custom length backsplash. See Casework Plan for more
information.
5. Shelf for water heater. Height of finished surface should be
72" AFF or less.

open to beyond

6. Water heater per Plumbing drawings.

x0009

10829

x0013

x0008

D. Paint finishes shall be applied as follows, unless otherwise


noted;
- All wood and metal surfaces shall be painted
Semigloss, or equal.
- All accent and trim paint to be Semigloss, or equal.
- All wall and ceiling paints to be Eggshell, or equal.

C 2011 Starbucks Coffee Company

Starbucks Coffee
Company

E. For Paint and Wall Treatment Schedules, refer to the Wall


Finish Plan. For Graphics Schedule, refer to the Furniture,
Fixtures, and Equipment Plan.

7. Existing door.

C. Paint substitutions are not allowed. Use Starbucks'


national account "color code" when ordering paints.

8. Place fire extinguisher in workroom per fire inspector.

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

9. Electrical panels. See Electrical drawings for more information.

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

10. 3-comp sink. See detail 5/I-505.


11. Ice machine with 6" clear space. See detail 7/I-503 & 4/I-505
and Plumbing drawings for more information.
12. Managers desk. See details 3 & 6/I-503.
13. Wall mounted handsink with soap dispenser and paper towel
dispenser. Ensure mounting heights conform to ADA code.
12087

14
11469

11403

10473

11469

14. Future refrigerator location.

11403

11403

15. Coat rack.

Drive-Thru POS
Scale:

3/8" = 1'-0"

Drive-Thru Window
Scale:

3/8" = 1'-0"

Drive-Thru Espresso
Scale:

16. Water filtration equipment. See Plumbing drawings.

3/8" = 1'-0"

17. Sanitizer set on casters for cleaning access.

11469

Architect of Record

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

11611

Rev

11419
11469

Date

Revision Schedule
By
Description

11469

11469

11469

16

10

7' - 0"

13

Scale:

3/8" = 1'-0"

Workroom - West Wall


Scale:

3/8" = 1'-0"

11403

Workroom - South Wall


Scale:

3/8" = 1'-0"

11403

Workroom
Scale:

3/8" = 1'-0"

Workroom - North Wall


Scale:

3/8" = 1'-0"

11469

11419

11469

Project Name:

11469

6
9
15
10820

12

Max.

6' - 0"

719 East Valley Road


Basalt, Colorado 81621
Eagle County

Workroom / Cafe wall

11403

Project Address:

11403

Highway 82 & Willits

17
11403

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:
11
11403

9
3/4/2013 1:00:20 PM

Max.

2' - 10"

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Workroom - East Wall


Scale:

3/8" = 1'-0"

10462

10

Workroom - Storage
Scale:

Sheet Title:

Interior Elevations

3/8" = 1'-0"

As indicated

Scale:

Sheet Number:

I-213

Enlarged Restroom Plan Notes


A. Details are for reference only.
B. All restroom accessories mounting heights to meet
accessibility requirements per Starbucks Accessibility
Standards.
C. General Contractor to verify all dimensions and notify
Starbucks Construction Manager of any discrepancies prior to
construction. All dimensions to be taken from designated datum
point.

R
C 2011 Starbucks Coffee Company

D. Dimensions are to face of finished surface.


10756

10769
1
I-402

10977

Starbucks Coffee
Company

Sheet Notes

10859

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

1. Restroom signage to be mounted on wall adjacent to door


latch as noted. Signage type, size and location to conform to
ADA code as required.
10172

10116
10093
10597

2. See fixture mounting heights and details on sheet I-402.

10099

3. Restroom elevations identical to opposite side.


3

I-401

1
4. Stain door to match chair rail.

1
10947

10862

11871

6. Align top of satin course with door frame, typ.

9"

UNISEX
RESTROOM

UNISEX
RESTROOM

9"

10862

7. Grey shade designates satin course.

2
4
1

I-212

5. Door frame to be HC-80 - Benjamin Moore "Bleeker Beige"

11871

8. White shade designates gloss course.

10947

9. Last row of tile. See detail 11/I-508 for tile to wall transition.
10116
10093
10597

5
10099

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

10172
10977

10859

Scale:

1
typ.

11
I-508

Revision Schedule
By
Description
Review Revision

typ.
5

x0024

x0024

x0024

x0026

1
9
7

typ.

Restroom at Front
Scale:

3/8" = 1'-0"

11403

11403

Restroom at Stall Side


Scale:

3/8" = 1'-0"

11403

11403

Restroom at Door
Scale:

3/8" = 1'-0"

Restroom at Sink Side


Scale:

3/8" = 1'-0"

719 East Valley Road


Basalt, Colorado 81621
Eagle County

1
typ.

Project Address:

4
8

Highway 82 & Willits

x0026

x0026

Project Name:

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Rev Date
1
12/4/12

1/2" = 1'-0"

1
x0024

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

10756

Restroom Plan

x0026

10769

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

3/4/2013 1:00:25 PM

Sheet Title:

Enlarged Restroom Plan


and Elevations
As indicated

Scale:

Sheet Number:

I-401

Enlarged Restroom Plan Notes


A. Details are for reference only.
B. All restroom accessories mounting heights to meet
accessibility requirements per Starbucks Accessibility
Standards.
4' - 8" Min.

Toilet paper dispenser


Vertical grab bar

3' - 6" Min.

1' - 0" Max.


39" - 41"

18" Vertical Grab bar

Seat cover dispenser

C. General Contractor to verify all dimensions and notify


Starbucks Construction Manager of any discrepancies prior to
construction. All dimensions to be taken from designated datum
point.
D. Dimensions are to face of finished surface.

42" Minimum Grab bar

Switch

Toilet paper dispenser

Coat hook
centered on
door

Seat cover dispenser

Grab Bar

Baby change station

tur

5' - 0"
7' - 2 5/8"

Lavatory clear
floor space

6"

ius
rad
g
nin

Soap
dispenser

Restroom at Door

3/8" = 1'-0"

4' - 0"

4' - 0"

2' - 9"

1' - 7"

39" - 41"

4' - 0" T.O. handle

17" - 19"

9"

2'

Restroom at Side
Scale:

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

1. Restroom signage to be mounted on wall adjacent to door


latch as noted. Signage type, size and location to conform to
ADA code as required.

6"
EQ.

Operable handle
opposite wall side

Starbucks Coffee
Company

Sheet Notes

7 1/2"

1' - 0"

3' - 0" Min.

EQ.

Water closet
clear floor space

Restroom signage
2' - 0"

C 2011 Starbucks Coffee Company

39" - 41"

Baby changing station

4" Max.

Scale:

3/8" = 1'-0"

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

2' - 6" Min


1' - 2"
1'-3" Min

Decorative mirror
Paper towel
dispenser

Rev
Soap
dispenser

36" Grab bar

NOTE: DETAIL FOR DESIGN


INTENT ONLY. MOUNTING
HARDWARE AND DETAILED
INSTALLATION INSTRUCTIONS
PROVIDED BY MANUFACTURERS
AND INCLUDED WITH BABY
CHANGING STATION.

Diaper Changing Equipment Details


Scale:

3/4" = 1'-0"

DIAPER CHANGING DETAIL

719 East Valley Road


Basalt, Colorado 81621
Eagle County

1' - 7 3/4"
4' 0" AFF

33"
ABOVE
FLOOR
MAX

NOTE: INSTALL DIAPER CHANGING STATION PER


MANUFACTURER SPECIFICATIONS

CHANGING STATION MOUNTING PLATE

6' - 9"
Bottom of
Soap Dispenser

3' - 3"

3/8" = 1'-0"

2' - 10"

NOTE: FASTENERS MUST PENETRATE 3 SUBSTRATES


AND FULLY ENGAGE WALL STUDS TO SUPPORT 250
POUNDS PER MANUFACTURERS RECOMMENDATIONS

EQUIPMENT MOUNTING HEIGHT

Scale:

3' - 0"

1' - 5"

6 1/4" 6 1/4"

4' - 1" AFF

1" RADIUS

3/8" = 1'-0"

PRE-DRILLED PER
MANUFACTURERS SCHEMATIC

LOCATE AND MOUNT


TO STUD
2' - 10"

Restroom at Front

8"

3/4" MEDEX

Scale:

Revision Schedule
By
Description

Project Address:

3/4" = 1'-0"

Restroom at Sink Side

2 1/4"

Scale:

Highway 82 & Willits

Restroom Plan

TYP
1' - 5"

Pipe thermal shield

2 1/4"

4' - 0"

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

7' - 0"

2' - 9"

Paper towel
dispenser

4' - 0" Min.

Max to Rim

1' - 2"

2' - 10"

4' - 0"

3' - 2"

6"

Date

GC to install 1/4" liquid


spacer above tile.
Liquid nail sides of
mirror frame to wall

Project Name:

4"

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Center of J Box

5
1' - 3" Min.

I-402

Light sconce

2' - 6" Min.

Coat hook

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

3/4/2013 1:00:26 PM

Sheet Title:

Restroom Details
As indicated

Scale:

Sheet Number:

I-402

Note: Final design to be created by Windfall.


For dimension reference only.

14' - 0"

Wall per floor plan


7 1/4"

EQ.

EQ.

1 1/2"

x0004

Starbucks Coffee
Company
2401 Utah Avenue South
Seattle, Washington 98134
(206) 318-1575

Top of Fixture
7'-3" AFF (VIF)

Custom community table top per


vendor. Center on table base

Community Table
Scale:

C 2011 Starbucks Coffee Company

Merch bay unit top cap

2' - 10 1/2"

2' - 0"

x0001
custom table
base per
schedule

"Z" clip attached to Merch


Bay top cap with (3) cap
screws. "Z" clip and cap
screws provided by vendor

1 3/4"

1 1/2"

7 1/4"

"Z" clip (G.C. provided)

3/4" = 1'-0"
#8 screws (G.C. provided)
1"x6"x32" wood blocking (paint to
match wall)

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Merch bay unit

Architect of Record

6' - 11"
Note: Final design to be created by Windfall.
For dimension reference only.

Merch Bay MCS - Wall Attachment


Scale:

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

6" = 1'-0"

Rev

Custom outdoor bench per vendor

1' - 6
"

x0006

Metal support leg

Date

Revision Schedule
By
Description

1' - 6"

17' - 7 1/2" R

4
I-501

16' - 1 1/2" R
Metal support leg

Exterior Bench
Scale:

12363
Solid wood
back panel

3/4" = 1'-0"

13331

13191
Install end panel at
outside face only

13191
Elevation

x0005

4' - 3 1/4"
V.I.F.

Install end panel at


outside face only

Section

719 East Valley Road


Basalt, Colorado 81621
Eagle County

4
I-502

Note: all dimensions must be


verified prior to fabrication

Project Name:

V.I.F.

Project Address:

5' - 1 3/4"

Highway 82 & Willits

To top of fixture

Merch Bay
unit

7' - 3"

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

6' - 3"

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

3/4/2013 1:00:28 PM

Plan

Custom Banquette
Scale:

1" = 1'-0"

Merch Bay MCS


Scale:

Sheet Title:

Casework Details

3/4" = 1'-0"

As indicated

Scale:

Sheet Number:

I-501

4' - 6 1/2"
Finish Panel
4' - 6 1/4"
Diewall
4' - 5 1/4"

EQ

EQ

EQ

EQ

EQ

EQ

C 2011 Starbucks Coffee Company

x0010
Top cap

Center fasteners vertically


on wall cleat solidly attached
to wall. See schedule "wall type fastener
schedule" for specifications.

Center fasteners vertically


on wall cleat solidly attached
to wall. See "wall type fastener
schedule" for specification.

x0012

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

1"x4" (25mm x 100mm)


furring strip or equivalent

x0011
x0013
Countertop

Finish Panel
2"

Similar fasteners at each stud


location across opening
(typical at all cabinets)

1"
Metal trim to be painted

Wall Type Fastener Schedule


Wall type Wall blocking
Wood Frame

Metal Frame

Fasteners

DDR-refer to architect of record wall blocking detail


NDR-refer to wall blocking detail this sheet

#8 x3" (75mm) WD
or equivalent

DDR-refer to architect of record wall blocking detail


#6ct. x11/4" (30mm) MTL/WD
NDR-refer to wall blocking detail this sheet
or equivalent

CMU

Min. 5/16"x3" (8mmx75mm)


tapcon or equivalent

NCT

Min. 1/4"x3" (7mmx75mm)


sleeve anchor or equivalent

BRICK

Min. 1/4"x1" (7mmx25mm)


wedge anchor or equivalent

Space per detail this sheet

2' - 6 1/4"

Stud wall blocking requirements

Notes

Reserve countertop

Wood stud walls require min. 2"x6" (50mmx150mm) wood blocking


secured flush to stud face with (3) 10d nails (or equivalent)

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Metal stud walls require min. 2"x6" (50mmx150mm) wood blocking


secured flush to stud face with min. (3) #6 ct. 1.25" (30mm) screws
(or equivalent)

Architect of Record

Space per detail this sheet


Space per detail this sheet
avoid setting anchors in mortar joints

See detail 6 below

Upper Cabinet Attachment


Scale:

Starbucks Coffee
Company

Diewall

Adjustable shelf (if applicable)

Top cap

EQ

6"

(6) fasteners evenly spaced


3" (75mm) minimum. Across
opening (typical at all cabinets)

Top cap

Verify in-wall blocking or


ensure solid attachment of
cleat to wall at each stud

1' - 0"

Varies

1 : 10

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Custom Workstation RES 03-01


Scale:

Rev

3/4" = 1'-0"

Date

Revision Schedule
By
Description

6' - 7 1/2"
VERIFY MIN. CLEARANCE FOR TOP OF
MENU SWING BELOW BACKBAR SOFFIT

9"
V.I.F.

USE WINGNUTS AS BRACKET MOUNT


TO ADJUST VERTICAL HEIGHT OF
MENU AS NEEDED

Cubby

See detail 5 above

VARIES

Cabinet bottom panel


Flex conduit to task light

Continuous light valance

Scale:

3/4" = 1'-0"

x0017

Task Light Detail


Scale:

3" = 1'-0"

x0016

x0015
Top cap

Custom Workstation RES 03-01 Continued


Scale:

3/4" = 1'-0"

Project Name:

Casework Menu Mounting

1/2"

Merch Bay Unit

Anchor Bolt or Lag Screw (GC


Provided)
- holes for anchor bolt/lag screw predrilled into cabinet frame

719 East Valley Road


Basalt, Colorado 81621
Eagle County

STORAGE CABINET AT BACK BAR WALL;


SEE UPPER CABINET ATTACHMENT DETAIL,
THIS SHEET

Project Address:

Under-cabinet task lights

Highway 82 & Willits

LIGHT VALANCE

sched.

ATTACHED PLASTIC MENU STOPS TO


CABINET VERTICAL EDGES (SUPPLIED BY
CASEWORK VENDOR)

12100
typ.

MENU BOARDS ARE HINGED TO ALLOW


ACCESS TO CABINET SHELVES BEHIND

3
I-502

per

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

ALIGN ALL TOPS OF CABINETS

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

x0008
Concrete Slab with Wall Clip:
Base cabinet to floor anchors to be "Titen HD"
3/8" x 2" when/where available or manufacturer
tested and owner approved substitute.
Anchors to provide working tension capacity of
250lb/100kg and working shear capacity of
50lb/25kg

Isometric View

3/4/2013 1:00:30 PM

Countertop
x0014

SCREW MENU HINGE TO TOP OF CABINET.


ALIGN PIANO HINGE JOINT TO CABINET EDGE

Merch Bay MCS - Floor Attachment


Scale:

3/4" = 1'-0"

Wood Flooring with Wall Clip:


When placed on wood flooring, substitute
anchor bolt with lag screw and secure to wood
frame floor sheathing and joist or solid blocking.
All other specifications still apply.

Checked by:

Note: all dimensions must be


verified prior to fabrication

8' - 2"
Countertop

Casework may vary from plans


- use electrical and plumbing
diagrams as reference only

Custom Espresso Countertop (Workstation ESP 37-01)


Scale:

Sheet Title:

Casework Details
As indicated

Scale:

3/4" = 1'-0"
Sheet Number:

I-502

Note: all dimensions must be


verified prior to fabrication

5' - 4 1/2"
No backsplash

Casework may vary from plans


- use electrical and plumbing
diagrams as reference only

Duplex receptacle for Security


Panel at 92" (2340mm) AFF

Backsplash

Quadplex receptacle for Security


Camera Power Supplies at 92"
(2340mm) AFF

Modified backsplash
length

Junction box for Relay Line


Panel at 92" (2340mm) AFF

R
C 2011 Starbucks Coffee Company

x0009

Junction box for


Telecommunication Wiring
at 92" (2340mm) AFF

Ceiling

Junction box for Security Panel at


92" (2340mm) AFF and 15"
(380mm) over from adjacent box

Modified backsplash
length
ADD 10-01

Duplex receptacle for WiFi


at 88" (2285mm) AFF

CBS 01-01

Starbucks Coffee
Company
2401 Utah Avenue South
Seattle, Washington 98134
(206) 318-1575

Junction box for High Speed Internet


and Telecommunication at 92"
(2340mm) AFF
11"

Duplex receptacle for Security


at 48" (1220mm) AFF

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

LAN Hub and Modem

Music System

3/4" = 1'-0"

Security Recorder

Dedicated duplex
receptacles for Workstation
at 42" (1070mm) AFF

Dedicated duplex receptacles for


Workstation at 42" (1070mm) AFF
9"

PC Monitor
Money Counter

1' - 4"

Printer

NOTES

1'-5" AFF (HW SUPPLY)

VARIES: 1/4" PER FOOT FALL


(ABS 2" WASTE LINE)

9"

A LIVE LOAD OF A PARTNER


EITHER PULLING AND/OR
CLIMBING ON THE CASEWORK

Junction box for LAN


Junction box for 1 Phone
Jacks at 12" (305mm) AFF

SEISMIC ACCELERATION
CONDITIONS AT THE SITE.

3
5

84"x24" (2130mmx610mm)
painted plywood backer board

Managers Workstation - Electrical - Generic


Scale:

3/4" = 1'-0"

Rev

Date

Revision Schedule
By
Description

NOTE:
BOTTOM TWO SHELVES
ARE INSTALLED W/ BRACKETS
DOWN

Interactive Equipment Rack


Scale:

3/4" = 1'-0"

FRENCH CLEAT REFER


TO AEC WEBSITE FOR
MOUNTING DETAILS

MENU BOARD HEIGHT ADJUSTABLE


7'-10" AFF

2'-10" AFF (BACKBAR COUNTERTOP)

Receptacle for Sanitizer


at 18" (460mm) AFF

1
ELECTRICAL OUTLET

2
2' - 2"

Receptacle for Ice Machine


at 72" (1830mm) AFF

Project Name:

SOLID SURFACE COUNTERTOP


WITH INTEGRAL BACKSPLASH

719 East Valley Road


Basalt, Colorado 81621
Eagle County

Receptacle for Refrigerator


and/or Freezer at 84"
(2135mm) AFF

BACKBAR TILE AT EXPOSED WALL


SURFACE BETWEEN BASE OF STORAGE
CUBBY AND TOP OF BACKSPLASH

Project Address:

1/4" GREEN BOARD TILE SUBSTRATE BY G.C.

Highway 82 & Willits

V.I.F.

4' - 5 3/4"

V.I.F.

2' - 10"

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Quadplex convenience
receptacle at 12"
(305mm) AFF

6"

1'-6" AFF (CWF SUPPLY)

45 LBS DEAD LOAD FOR LIQUID


STORAGE OVER AND ABOVE
THE CASEWORK ITSELF

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

16"

CHATSWORTH PRODUCTS
#40074-500 SINGLE-SIDED
SHELF, TYP.

Junction box for POS Phone


6 1/2"

1'-7" AFF (CW SUPPLY)

Architect of Record

CHATSWORTH PRODUCTS
#1532 1-5 24 HEAVY DUTY
WALL-MOUNT EQUIPMENT
RACK

Manager's CPU

2-Line Phone

84"H x 24"W x 3/4"D


PAINTED A/C PLYWOOD
BACKER BOARD

6-1/2"

Scale:

Duplex receptacle for Music


System at 48" (1220mm) AFF

73-1/2"

Custom Countertops

Security Monitor

6" 5"

x0020

11"

x0021

6' - 1 1/2"

Amp

3
4
ADJUSTABLE LEGS

TILE BASE

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

Wall Section at Backbar


Scale:

3/4" = 1'-0"

Refrigerator - Electrical
Scale:

3/4" = 1'-0"

Sanitizing Workstation - Electrical


Scale:

3/4" = 1'-0"

Ice Machine - Electrical


Scale:

3/4" = 1'-0"

3/4/2013 1:00:32 PM

Sheet Title:

Casework Details
3/4" = 1'-0"

Scale:

Sheet Number:

I-503

Note: all dimensions must be


verified prior to fabrication
Casework may vary from plans
- use electrical and plumbing
diagrams as reference only

9' - 9"
2' - 2"

2' - 1"

6' - 6"

4' - 0"
10"

3 1/2" 8 1/2"

11"

1' - 11"
C 2011 Starbucks Coffee Company

Power & Data receptacles above counter


- (2) Dedicated duplex receptacle for wireless base
& signal proccessor @ 7'-6" AFF
- (2) Data Junction Box @ 7'-6" AFF
Receptacle for Grinder/Scale
at 26" (660mm) AFF

Countertop (above)

Receptacle for Coffee Warmers at 26"


(660mm) AFF

Double duplex receptacle for Coffee


Warmer at 26" (660mm) AFF

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Power & Data receptacles


- (2) Dedicated Double duplex receptacle for
Drive Thru Monitor and CCTV monitor @ 6'-3" AFF
- (2) Data Junction Box @ 6'-3" AFF

Brew 09 - Electrical
Scale:

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

Receptacle for Undercounter Refrigerator at


26" (660mm) AFF

Receptacle for Brewer


at 26" (660mm) AFF

Starbucks Coffee
Company

3/4" = 1'-0"
Electrical Components

Double duplex receptacle and data outlet for Drive-thru


Register and Expeditor Register at 18" (660mm) AFF

10091 Tall Hot


10855 Grande/ Venti Hot

Receptacle for Undercounter


Refrigerator at 26" (660mm) AFF

6' - 7"
2' - 2 1/4"

1' - 1 3/4"

1' - 1"

Receptacle and Data junction


box for Cup Labeler at 26"
(660mm) AFF

Cup Dispensers at DT Espresso


Scale:

Architect of Record

3/4" = 1'-0"

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Optional Cup Labeler

10396 Short Hot

Receptacle(s) for Blender(s) at


26" (660mm) AFF.

10091 Tall Hot

Rev

Date

Revision Schedule
By
Description

10855 Grande/Venti Hot

Optional Blender
Plan View

CBS 01 - Electrical
Scale:

3/4" = 1'-0"

POS 33 - Electrical
Scale:

3/4" = 1'-0"

Cup Dispensers at DT POS


Scale:

3/4" = 1'-0"

Grandi/Venti Hot 10855


3' - 1 3/4"

8' - 2"
1' - 3 3/4"

2' - 5"

7 1/4"

10"

Data Junction Box at 18" (460mm) AFF


Double duplex receptacle at 18" (460mm) AFF

2' - 0 1/4"

Tall Hot 10091

Box base

Receptacle for Undercounter Refrigerator at


26" (660mm) AFF

Cup Dispensers at Brew/Grind


Scale:

3/4" = 1'-0"

Juntion box for Phone at 18"


(460mm) AFF

Receptacle for future Espresso Machine at


26" (660mm) AFF
Receptacle and Data junction box
for Cup Labeler at 26" (660mm) AFF
Electrical Components

Electrical Components

Dedicated POS duplex receptacle at


18" (460mm) AFF
Receptacle and Junction Box for Safe
security at 18" (460mm) AFF

16"x3" (405mmx75mm) stub-up penetration


area for Power and Data conduits.
See Electrical Plan for final location

Grandi/Venti Hot 10855

10091 Tall Hot

Countertop (above)

10396 Short Hot

Box base (below)

Future Espresso
Machine layout

Grandi/Venti Cold 10791

Cup Caddy
Scale:

3/4" = 1'-0"

10858 Tall Cold

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

Plan View

Sheet Title:

Plan View

3/4/2013 1:00:34 PM

719 East Valley Road


Basalt, Colorado 81621
Eagle County

18"x3" (460mmx75mm) stub-up


penetration area. Supply Power,
Data, and Phone conduits for POS,
and Power conduit for Pastry Case.
See Electrical Design Plan for final
location

Project Address:

Receptacle for Instant Hot Water Tap at 26"


(660mm) AFF
Receptacle for Espresso Machine at 26"
(660mm) AFF

Highway 82 & Willits

Short Hot 10396

Countertop (above)

Project Name:

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Casework Details
3

Espresso 37 - Electrical (Modified)


Scale:

3/4" = 1'-0"

POS 13 - Electrical
Scale:

3/4" = 1'-0"

Scale:

3/4" = 1'-0"
Sheet Number:

I-504

Note: all dimensions must be


verified prior to fabrication
Casework may vary from plans
- use electrical and plumbing
diagrams as reference only

5' - 0"
C 2011 Starbucks Coffee Company

2' - 6"

1' - 3"

Clear

Starbucks Coffee
Company

1' - 5 1/4"

10"

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

Receptacle for future Undercounter Refrigerator


at 26" (660mm) AFF

6"

Receptacle for Scale/Grinder at 26"


(660mm) AFF

Double duplex
receptacle for
Refrigerator
and Cup
Labeler at 26"
(660mm) AFF

Receptacle for Clover Machine at


26" (660mm) AFF

Back wall

Data Junction
Box for Cup
Labeler at
26" (660mm)
AFF

Filtered cold water


for Ice Machine

Receptacle for
Warming
Oven at 26"
(660mm) AFF

See Plumbing Plan for


final floor drain location
and type

Indirect drain line


from Ice Machine
to floor drain

Data Junction Box at 26" (660mm) AFF.


Include pull strings for future use.

1'
-3

Warming 03 - Electrical

4"
3/

Scale:

3/4" = 1'-0"

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

Ice Machine - Plumbing


Scale:

3/4" = 1'-0"

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Toe Kick (below)

Reserve 03 - Electrical (Modified)


Scale:

Rev

Date

Revision Schedule
By
Description

3/4" = 1'-0"

Drain line from Sink to waste


line in wall or floor drain
Hot and cold water for Sink Faucet

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Back wall

2' - 3 1/4"

5 1/4"

1' - 6 3/4"

Indirect drain line from


Sanitizer to nearest floor drain
or Mop Sink

9"

Hot water for Sanitizer with


shut-off under sink at 18"
(460mm) AFF. Line length
must allow ease of movement

Countertop (above)
Receptacle for Instant Hot
Water Tap at 26" (660mm)
AFF

See Plumbing Plan for final floor


drain location. Floor drain optional.

Receptacle for
Undercounter Refrigerator
at 26" (660mm) AFF

Receptacle and Data junction


box for Cup Labeler at 26"
(660mm) AFF
Electrical Components
Toe Kick

1' - 6"

Receptacles for
Espresso Machines at
26" (660mm) AFF

Compartment sink

Project Name:

Wire rack

Sanitizer

4' - 6"

Toe Kick (below)

Keep clear at backwall


for chemical dispensing
system, to be installed by
system vendor. Refer to
posted installation
guidelines for more
information.

Note:
For coordination only. See
Furniture Fixtures and
Equipment Plan for equipment
locations. Refer to Item
Specifications for more
information.

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

Plan View

3/4/2013 1:00:36 PM

1' - 0"

719 East Valley Road


Basalt, Colorado 81621
Eagle County

1' - 0"

Project Address:

21"x3" (530mmx75mm)
stub-up penetration area for
Power and Data.
See Electrical Plan for final
location

Highway 82 & Willits

Plan View

Elevation View

Sheet Title:

Casework Details
2

Espresso 27 - Electrical (Modified)


Scale:

3/4" = 1'-0"

Sanitizing (generic) - Plumbing


Scale:

3/4" = 1'-0"

3/4" = 1'-0"

Scale:

Sheet Number:

I-505

Filtered Cold water supply for Clover


Machine

Filtered Cold Water supply for


Brewer with shut-off in cabinet
at 24" (610mm) AFF
Open ceiling
tiles, above
water heater

Indirect drain line from Clover


Machine to floor sink

7"x3" (180mmx75mm) stub-up penetration area from


adjacent Espresso Station
See Plumbing Plan for final locations.
Install shut-off valves between stub-ups and equipment

9' - 9"
6' - 10 1/2"

Direct drain line from Sink.


Rough-in sink waste stub
at 15 1/2" (394mm) AFF
and centerline of sink

Water
heater

Reserve 03 - Plumbing
Scale:

Brew 09 - Plumbing
Scale:

3/4" = 1'-0"

6' - 7"
Mop holder
1' - 0"
Legs (below)

2' - 0"

Wire rack

5' - 10"

Hot and cold water for Sink Faucet at 20


1/2" (520mm) AFF. Shut-off valves at wall
and 4" (102mm) either side of waste line

2' - 5 1/2"

Hose clip

Tempered hot and cold water


for Sink Faucet at 20 1/2"
(520mm) AFF. Shut-off
valves at wall and 4" (102mm)
either side of waste line

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Cold water supply for Pitcher Rinser.


FRP enclosed
2' - 0"

Indirect drain line from Sink to floor sink

ADD 01 - Plumbing
3/4" = 1'-0"

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Scale:

3/4" = 1'-0"

Revision Schedule
By
Description

CBS 01 - Plumbing
Scale:

3/4" = 1'-0"

4' - 10 1/4"

See Plumbing Plan for


final floor sink location
and type. Coordinate
location with support legs
Countertop (above)

Indirect drain line from Espresso Machine to floor sink

8' - 2"

Indirect drain line from Ice Bin to floor sink


Plumbing Components
Indirect drain line from In-use Utensil Rinse Sink to floor sink

Plumbing Components

See Plumbing Plan for final floor sink location and type.
Coordinate location with support legs

Cold water supply for


Metered spoon rinser
faucet
Floor sink (below)

Legs
Countertop (above)

Filtered Cold water supply for Water Tower Faucet

7"x3" (180mmx75mm)
stub-up penetration area.
See Plumbing Plan for
final locations.
Install shut-off valves
between stub-ups and
equipment

Note: all dimensions must be


verified prior to fabrication

Hot and Cold water


supply for Pitcher
Rinser faucet

Casework may vary from plans


- use electrical and plumbing
diagrams as reference only

Filtered Cold water


supply for Instant
Hot Water Tap

Filtered Cold water supply for Instant Hot Water Tap

Toe Kick (below)

Filtered Cold water


supply for Espresso
Machine (typ)
Hot and Cold water supply for Pitcher Rinser faucet

719 East Valley Road


Basalt, Colorado 81621
Eagle County

Indirect drain line from


Espresso Machine to
floor sink (typ)

Project Address:

Indirect drain line from


Ice Bin to floor sink

Project Name:

2' - 0"

2' - 2 3/4"

7"x3" (180mmx75mm) stub-up penetration area.


See Plumbing Plan for final locations.
Install shut-off valves between stub-ups and
equipment

Highway 82 & Willits

Toe Kick

6' - 8 1/2"

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:
Cold water supply for Metered spoon rinser faucet
Filtered Cold water
supply for Water
Tower Faucet

Filtered Cold water supply for Espresso Machine


Plan View

3/4/2013 1:00:37 PM

Date

See Plumbing Plan for final floor sink location


and type

Mop Sink (stacked) - Plumbing


Scale:

Rev

Indirect drain line from Ice Bin to


floor sink

Mop sink

Architect of Record

Indirect drain line from Drain Board


to floor sink

Faucet

Direct drain line from


Sink. Rough-in sink
waste stub at 15 1/2"
(394mm) AFF and
centerline of sink

1' - 0"

7 1/2"

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575
These Drawings and Specifications are confidential
and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

3/4" = 1'-0"

1' - 3"

Starbucks Coffee
Company

Legs (below)

Toe Kick (below)

C 2011 Starbucks Coffee Company

Hot and cold water for Sink


Faucet at 20 1/2" (520mm)
AFF. Shut-off valves at
wall and 4" (102mm) either
side of waste line

Strap units
per local
code, if
needed

Note:
Station intended to share
same floor sink as Espresso
Bar. See Plumbing Plan for
shared location.

Floor sink (below)

Espresso 37 - Plumbing (Modified)


Scale:

3/4" = 1'-0"

Casework Details

Plan View

Legs (below)

Sheet Title:

Espresso 27 - Plumbing (Modified)


Scale:

3/4" = 1'-0"

Scale:

3/4" = 1'-0"
Sheet Number:

I-506

NOTE: WALL DIMENSIONS VARY PER PLAN

1/2"

*VARIES*
Deep leg
slip track
(if required)

Roof deck above

- Do not fasten gwb to slip track (typ)

Top track
(if required)
6" min.

METAL STUDS (PER WALL TYPE)


@ 16" O.C. TO UNDERSIDE OF
ROOF STRUCTURE, TO MINIMUM
OF 6" ABOVE SUSPENDED
CEILING OR TO UNDERSIDE OF
EXISTING SOFFIT OR CEILING.
METAL STUDS TO MEET I.C.B.O.
#1715P OR EQUAL

20 GA 3-5/8" steel stud bracing at 48"


O.C. Attach to partition framing with
3/8" pan head type 'S' screws. Use
lateral bracing when partition framing
does not attach to roof structure. GC to
verify if required.

2"

5/8" GWB TYPE "X" DOUBLE


SIDED, TO MINIMUM OF 6"
ABOVE CEILING. TYPE "S"
DRYWALL SCREWS @ 8" O.C. TO
VERTICAL EDGES & 12" O.C. TO
INTERMEDIATE STUDS.
STAGGER 24" O.C. EACH SIDE.
OFFSET BASE OF GWB 1/4" AFF.

GWB as occurs.
6" WALL BASE TILE

NAIL STUD RUNNER TO


FLOOR WITH HILTI NK
FASTENERS, 1-1/8"
MINIMUM PENETRATION @
32" O.C. MAXIMUM.
(L.A.R.R.#2388)
1
I-508

Mtl. studs per


wall type

5/8" GWB type to a minimun of 6" above ceiling. Type


'S' dry wall screws at 8" O.C. to vertical edges and 12"
O.C. to intermediate studs. Stagger joints 24" each side.

EXISTING FLOOR

- Greater stud sizes (depths) shall be permitted to


be used in metal or wood stud systems.

C 2011 Starbucks Coffee Company

Starbucks Coffee
Company

Metal studs of heavier gage than those tested


shall be permitted. The assigned rating of any
load bearing system shall also apply to the same
system when used as a non load bearing system.
Indicated stud spacings are maximums.
'Steel stud manufacturers association' for interior
non-structural non-composite table (5psf l/240)

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575
These Drawings and Specifications are confidential
and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Re: SBC 2209.1

Typical Partition Wall


Scale:

1 1/2" = 1'-0"

Sliding bracket attached to


tee flange with #14x1/2"
Hex-Head Sh. Mtl. Screws

New Partition Wall @ Floor

4'-0" O.C.

1 1/2" = 1'-0"
3" max

Scale:

- GC to determine, based on field conditions to


adopt stud to deck or stud braced to deck.

3 5/8" metal stud 20GA 16" oc Limiting ht. 15'-0"


(362S125-30)

Note:
- GC to install slip track to structure per
manufacturers recommendations.

All wire ties to be three tight


turns around itsdelf within 3
inches. Twelve gage hanger
wire spaced 4 feet on center,
or 10 gage wire spaced 5 feet
on center.

Architect of Record

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Main Tee
Lighting fixture track attached to
sliding bracket above ACT w/ #12x1
1/2" panhead Sh. Mtl. Screws @ 2'0" O.C

Existing deck above

Surface Mounted Track


Scale:

Wall

3" = 1'-0"

Scale:

COMPRESSION STRUT GUIDELINES

New 20 Ga 3-5/8" metal studs at 16"


O.C. with 5/8" GWB on one side.
Drywall screws @ 12" O.C., 45
degrees.

Vertical
hanging
wire

New wall at backbar

COMPRESSION STRUT SIZE

#12 Hanger wire


splayed at 45 degrees

A
Bottom of Finish
9' - 0" AFF

MAXIMUM LENGTH

3/4" DIAMETER CONDUIT

8'-6"

1" DIAMETER CONDUIT (EMT)

10'-0"

SINGLE 2 1/2" X 20 GAUGE METAL STUD (1 MIN. = 0.18")

11'-6"

BACK-TO-BACK 2 1/2" X 20 GAUGE METAL STUD


SCREWED TOGETHER @ 24" O.C.

15'-0"

2" max from bracing wires


to cross tees

45

45

12 GA hanger wire at 48"


OC each way to be attached
at max of 45 degrees, min of
4 tight turns in 1 1/2" at both
sides of all bracing wire, typ.

A-A
45

Attach 4 wires within 2" of cross


runners at points to comply with
ASCE 7-02 and CISCA - zone 3-4

1/2" metal edge trim at top of GWB

45

Existing deck above

Main runner at 4'-0" OC

Project Name:

1 1/2" = 1'-0"

719 East Valley Road


Basalt, Colorado 81621
Eagle County

Seismic Bracing

Project Address:

Soffit Detail

Vertical compression strut

Highway 82 & Willits

A
Note: install all suspended
ceiling components to comply
with ASCE 7-02, section 9.6
and CISCA-zone 3-4

Scale:

Revision Schedule
By
Description

3" = 1'-0"

GWB ceiling. See


Reflected Ceiling Plan

Spreader bar or other suitable system required to keep


perimeter components from spreading apart. Spreader
bars are not required if a 90 degree intersecting cross
or main is with in 8" of perimeter wall.

Date

Ceiling Grid at Wall

45

3/4/2013 1:00:39 PM

90

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

20 GA 3-5/8" steel stud bracing at 48"


O.C. Attach to partition framing with 3/8"
pan head type 'S' screws. GC to verify if
required.

ACT Main and


cross tee.

Rev

Shim as needed
20 GA 3-5/8" steel stud bracing at 48"
O.C. Attach to partition framing with 3/8"
pan head type 'S' screws. GC to verify if
required.

GWB ceiling. See


Reflected Ceiling Plan
2' - 0"

Cross tee at 2'-0" OC or


1'-0" OC as shown

3/4" EMT

2' - 0"

Hanger wire in tube

1/2" EMT

New 20 Ga 3-5/8" metal studs at 16"


O.C. with 5/8" GWB on one side.
Drywall screws @ 12" O.C., 45
degrees.

1. All 24"x48" ceiling light fixtures and 24"x24" HVAC air registers shall Be supported
by a minimum of (2) hangers at opposite corners. Ceiling system shall not support
other items.

1/2" EMT

2. All interior wall & ceiling finishes shall be installed to Class III Flame Spread or as
required by local building department, whichever is most stringent.

#12 Hanger
wire
Pin thru
hanger wire
Notch

Bottom of Finish
8' - 0" AFF

Main hanger
Per Reflected Ceiling Plan

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Notes:

Angle brackets
Top of Finish
9' - 0" AFF

Store #:

Checked by:

3. 45 degree brace wires and compression studs are to be provided only If required by
local building department.

Note: use EMT


(electrical metallic
tubing) as shown
if required by
CISCA - zone 3-4

4. Compression struts: steel section with L/R ratio of 200 maximum. Attach to main
runners with 1/4" machine bolt and to structure with 3/16" diameter power driven stud.
Compression strut shall not replace hanger wire.

Sheet Title:

Design Details
As indicated

Scale:

Soffit Over Community Table


Scale:

1 1/2" = 1'-0"

ACT Hanger
Scale:

3/8" = 1'-0"

TBar Ceiling Detail Seismic Requirements


Scale:

1" = 1'-0"
Sheet Number:

I-507

Casework

Gypsum wall

Fiberglass reinforced plastic


6" (152mm) +/Finish panel
Die wall

Bullnose sanitary coved tile base

3/4"

Finishes per Wall


Finish Plan

Vinyl wallcovering

Casework box base


Min 2 1/2"

Bullnose sanitary
coved tile base
Bullnose sanitary
coved tile base

Finish Flooring

Flooring Material

Mitered edge at corner.


Sand smooth and finish per
specifications

Flooring Adhesive
Min 2 1/2"

Scale:

3" = 1'-0"

Tile Base - Integral Set at Die Wall


Scale:

3" = 1'-0"

Tile Base - Integral at Cabinet


Scale:

3/4"

3" = 1'-0"

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575

Base

Metal Corner Guard


Scale:

3/4" = 1'-0"

Chair Rail Corner


Scale:

6" = 1'-0"

Architect of Record
Vinyl wallcovering applied directly to
wall per Manufacturer's instructions

1"x4" (25mmx100mm) Solid wood


chair rail attached to wall with
construction adhesive and nails
spaced 24" (610mm) apart. Fill all
nail holes.

See detail 7/I-501 for elevation

Wall covering applied directly to


wall according to manufacturer's
instructions

1"

Chair rail to overlap vinyl


wallcovering
1"

9
I-508

Latex caulking

4"

EQ

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Per Interior Elevations

Latex caulking

Solid wood chair rail attached to


wall with construction adhesive
and nail at 24" (610mm) spacing,
fill all nail holes
1/2 Offset (Brick)

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Gypsum wall

Gypsum wallboard; paint


per interior elevations
Per Interior Elevations

EQ

Starbucks Coffee
Company

Gypsum wall board

Chair rail

8
I-508

C 2011 Starbucks Coffee Company

Metal corner guard,


clear matte finish

Sub-Floor Structure/ Substrate


Min. 5" wide Flexible Waterproof
Membrane (min 12 mil thickness)
applied to sub-floor and casework
base. Adhere to substrate per
manufacturer recommendation

Tile Base at Wall

Wood maple veneer panels


(where specified)

Shim as needed

Existing concrete flooring

Miter and ease all


outside chair rail corners

Wood chair rail

TYP. AFF

Wall per plan

Textured Vinyl Wall Paper;


stripe pattern to run vertically

Rev Date
1
12/4/12

New base to overlap vinyl


wallcovering

Revision Schedule
By
Description
Review Revision

Tile base

Tile base
Clear latex caulking

Backbar Wall Tile Pattern - 1/2 Offset


Scale:

1 1/2" = 1'-0"

Wallpaper Section
Scale:

1 1/2" = 1'-0"

Chair Rail Section


Scale:

6" = 1'-0"

Vinyl Application - New Tile Base


Scale:

6" = 1'-0"

10

Wallpaper Elevation
Scale:

1 1/2" = 1'-0"

Gypsum wall board

Cementitious board
G.W.B.

Schluter - Jolly, aluminum


wall tile finishing edge.
Finish: AKGB - Brushed
Graphite Anodized
Aluminum

Grout

Cementitious board

Substrate, typ.

GWB wall assembly

Wall tile

1/2 " (15mm) shim

Grout
Grout, typ.

Dimension Point

Vinyl wallcovering,
typ. below chair rail

Schluter - Quadec,
aluminum wall tile
finishing edge. Finish:
ABGB - Brushed
Antique Bronze
Anodized Aluminum

Grout, typ.
Wall tile
Cementitious board

3/8" (12mm) "L"


shaped metal trim

Solid surface backsplash

Chair rail above


Stainless steel backsplash
(where occurs)

Metal corner guard

Open area behind


solid surface

Wall tile

11

Wall Tile Trim


Scale:

12

6" = 1'-0"

Butyl Rubber Caulk

16 GA. metal stud


5/8" GWB, typ.

Tile Corner Trim


Scale:

6" = 1'-0"

13

Wall Tile Above Solid Surface Backsplash


Scale:

3" = 1'-0"

14

Wall Tile Above Sainless Steel Backsplash


Scale:

3" = 1'-0"

15

Wainscot Vertical Corner Trim Section


Scale:

3" = 1'-0"

719 East Valley Road


Basalt, Colorado 81621
Eagle County

Wall tile

Project Address:

Wall tile

Highway 82 & Willits

Painted wall

Gypsum wall board

Project Name:

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Vinyl wallcovering applied directly to


wall per Manufacturer's instructions

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:
Tub

FRP

3/4/2013 1:00:41 PM

Sheet Title:

Design Details
16

FRP @ Mop Sink


Scale:

As indicated

Scale:

1 1/2" = 1'-0"
Sheet Number:

I-508

8" Max.

10 GA wire hangers at perimeter


supporting main runners and cross
runners 8" max. from edge

10 GA hanger wires at 4'-0" on center max.


each way, typ.
Main runners: 1 1/2" channels at
4'-0" on center max.

Continuous angle at wall edge, typ.


C 2011 Starbucks Coffee Company

Starbucks Coffee
Company
2401 Utah Avenue South
Seattle, Washington 98134
(206) 318-1575

5/8" type 'X' GWB

10 GA lateral bracing wires 2'-0" max. from channel


intersection at approximately 45 degrees in each
direction. Located on a 8'-0" x 12'-0" O.C. grid and
a max. 6'-0" from walls

Architect of Record

Suspended GWB Ceiling


Scale:

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

3/8" = 1'-0"

Date

Highway 82 & Willits

Project Name:

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Rev

Revision Schedule
By
Description

719 East Valley Road


Basalt, Colorado 81621
Eagle County

1 1/2" flange grid at 24" O.C. Max.

Project Address:

45

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

3/4/2013 1:00:42 PM

Sheet Title:

Design Details
3/8" = 1'-0"

Scale:

Sheet Number:

I-509

Count

x0004
1
Fixed Multiple Seating
12187
7
12379

12482

x0005

x0006
1
Furniture & Accessories
10756
2
10820
1
12282
16

3/4/2013 1:00:43 PM

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

12330

Bollard

GC

DT Window Shelf - 48in - Stainless

VD

Umbrella - 72in - Logo

SB

DT Pre Menu - Freestanding


DT 5 Panel Menu - Freestanding

VD
VD

Bike Rack
DT Speaker Post
Umbrella - Base for Canopy - Silver
MT0021

LL
SB
SB

Description

10605

10809

Community Table Top

VD

Table - Base Cafe Dome Accent - 18x28in


455x710mm - Hot Rolled Steel MT0011
Table - Occasional X Base - Aged Dark
Brown CM0001
Banquette - Metal Strap Base and Fixed
Back - 5ft 152cm - Navy Blue Flat F0015
Banquette - Metal Strap Base and Fixed
Back - Custom
Custom Bench

SB

Coat Hook 1 Prong Square - 2in - SST


Coat Hook Strip - 46in
Chair - Cafe Bent Plywood - Amber Honey
WD0005
Chair - Lounge Barrel Back - Red Orange
Natural F0026

Desk - Managers Workstation 60x30x30in - Almond Laminate


Desk - Managers Workstation Keyboard
Tray - Black Plastic
Desk - Managers Workstation Shelves
Wall Mounted - Almond Laminate

Design ID
Count
Description
Glazed Doors & Entrances
x0035
1
Door - Single Storefront Metal Frame
Interior Doors
10190
2
Door - Single Flush - 36in 915mm

Description

Comments
Mnfr: Windfall

SB
VD
VD
VD

Mnfr: Windfall

SB
SB
SB

Data Device Schedule


Design ID
Count
Description
Responsibility
Data Networking
10002
1
Computer Manager Workstation
VD
10007
1
Printer Manager Workstation
VD
10019
1
Wide Area Network Hardware
VD
Other Equipment
10028
1
Safe - Base
VD
Other Special Control& Instrumentation
10012
1
DT Communication System
VD
Public Address & Music Systems
10005
1
Music System
SB
10017
4
Speaker Surface Mounted - (Designer
SB
Specify) White or Black
10076
1
Amplifier
SB
Security & Detection Systems
10004
1
Alarm System
VD
Security Equipment
10010
2
Monitor - 15in 380mm
VD
10024
1
Safe - LH - 20x18x26in
VD
12336
1
DT Timer System Monitor - 17in 430mm
VD
Shelving
10011
1
Equipment Rack - 6ft
VD
Telephone Systems
10000
1
Phone 1 Line
OPS
10001
1
Phone 2 Line
OPS
Teller & Service Equipment
10003
1
Register Full Size
VD
10008
3
Register Compact
VD
10014
3
POS Printer
VD
10022
1
Money Counter
VD
10075
4
Cup Labeler
VD
Vault Equipment
10029
6
POS Bank
SB

Comments

Design ID
Signage
11305

Count

Description

11392

12732

13157

13163

Sign - DT Directional DF Illuminated - 33in


840mm
Sign - Inline Illuminated Flush Mounted 14in 355mm White
Sign - DT Clearance Bar Freestanding
Black MT0028
Sign - Disk DF Illuminated Suspended
Evolved - 24in 610mm
Sign - Disk SF Illuminated Flush Mounted
Evolved - 48in 1220mm

Signage Schedule
Responsibility

Bulb

Comments

SB
SB

Sign will not have internal illumination

SB

C 2011 Starbucks Coffee Company

SB
SB

Starbucks Coffee
Company

Sign will not have internal illumination

2401 Utah Avenue South


Seattle, Washington 98134
(206) 318-1575
These Drawings and Specifications are confidential
and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Architect of Record

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

SB

Design ID
Count
Bath & Toilet Accessories
10099
2
10172
2
10769
2
10859
2
10862
2
10977
3

SB
SB
SB
SB
SB
SB

SB
SB
SB
SB
GC

Mnfr: Winfall. Based on ID #12271

SB

24in (600mm) square carpet tiles placed in


a 6x8ft (183x243cm) area rug
configuration

SB
SB
SB

Door Schedule
Responsibility

Design ID
Count
Movable Artwork
10093
2
11162
2
12693
1

30" tall, typ.

Furniture Schedule
Responsibility

Movable Multiple Seating


10513
10
Table - Cafe Metal Suite Round - 28in
710mm - Black MT0022
12145
2
Ottoman - with Wood Base Round Polyurethane F0019
12149
26
Chair - Cafe Slatted Metal Suite - Black
MT0022
12160
2
Table - Accessible Metal Suite - 39x23in
990x585mm - Black MT0022
12161
1
Table - Cafe Metal Suite Square - 30in
760mm - Black MT0022
12241
2
Table - Accessible Metal Strap Base 38x24in 965x610mm - Amber Honey
WD0005
12321
3
Chair - Stool 29in 735mm Industrial with
Back - Dark Brown Pressboard WD0036
12383
1
Sofa Wood Arm Caps and Nailheads 60in 1525mm - Red Orange Woven F0027
12490
13
Chair - Stool 24in 610mm Industrial with
Back - Pressboard
12722
7
Table - Top Round - 24in 610mm - Amber
Honey WD0005
x0001
1
Table - Base Community I Beam - Hot
Rolled Steel MT0011
Movable Rugs & Mats
13298
1
Rug - Carpet Tile - 6x8ft 183x243cm Brown
Office Equipment
10123
1

Comments

GC

Comments
Match existing storefront system

GC

Graphics Schedule
Responsibility

12859

12860

12976

13214

13312

x0028

Mirror - Restroom - 18x30in


Restroom Sign Unisex
Community Board Magnetic - Medium
Warm Brown WD0004 - 36x46in
915x1170mm
Menu Board - 2 Panel Insert Style
Universal Mount
Menu Board - 3 Panel Insert Style
Universal Mount
Menu Board - Daily Offering Chalkboard
Universal Mount Rectangular
Menu Board - 1 Front Panel Insert Style
Reserve LH
Menu Board - 1 Front Panel Insert Style
Reserve RH
Custom Art - 24x36in

GC
SB
SB

x0029

Custom Art - 24x36in

VD

x0030

Custom Art - 46x34in

VD

Comments

SB
SB
SB
SB
SB
VD

Ferrari; Image ID #NS0187. Frame; 2 1/2"


Color: FCP633268 Distressed Wood-White
Ferrari; Image ID #NS0187. Frame; 2 1/2"
Color: FCP633268 Distressed Wood-White
Ferrari; Image ID #NS0187. Frame; 2 1/2"
Color: FCP633268 Distressed Wood-White

Specialty Equipment Schedule


Description
Responsibility
Restroom Toilet Paper Holder
Restroom Seat Cover Dispenser
Restroom Grab Bar Vertical - 18in
Restroom Grab Bar - 48in
Restroom Grab Bar - 36in
Paper Towel Dispenser Full Size Translucent Grey
Soap Dispenser Sink Mounted

11115
1
Fire Extinguishers
10501
1
Fire Extinguisher
Food Service - Appliances & Equipment
10102
1
Ice - Bin 590lb
10110
1
Fridge Reach In 1 Door RH - 29in
10267
3
Fridge Undercounter 1 Door - 27in
10312
3
Brewer Soft Heat Single Warming Stand
10344
1
Ice - Bin Drop In 95lb
10473
1
Fridge Undercounter 2 Door - 48in
10527
2
Ice - Bin Drop In 45lb
10672
1
DT Pastry Case Countertop Ambient - 28in
10724
1
Grinder Grindmaster
10746
1
Brewer Soft Heat Dual
10797
1
Pastry Case with Self Serve - 66in Bronze
10856
5
Brewer Soft Heat Server
10967
1
Freezer Reach In 2 Door - 51in
10971
1
Ice - Machine 625lb Air Cooled Side Vent
11083
2
Fridge Reach In 2 Door - 51x35in
11851
1
Brewer Clover
12407
1
Oven TurboChef Next Generation
12508
2
Blender Quiet Model On Counter
12618
1
Fridge Undercounter 1 Door with Shelf 27in 685mm
12631
1
Grinder Ditting KR804
12694
2
Espresso Machine Mastrena
Lockers
10293
1
10 Comp Locker
Office Equipment
10467
1
File Cabinet 2 Drawer
Other Equipment
10091
4
Cup Dispenser Tall Hot Vertical
10182
1
DT Espresso Topping Rail
10314
1
Scale Digital with Adjustable Display
Mount
10396
3
Cup Dispenser Short Hot Vertical
10791
3
Cup Dispenser Grande Venti Cold Vertical
10855
7
Cup Dispenser Grande Venti Hot Vertical
10858
1
Cup Dispenser Tall Cold Vertical
10947
3
Soap Dispenser Wall Mounted
11823
1
Scale Digital for Clover
x0033
1
Mobile Cup Dispenser Caddy
Parts Bins
10305
2
Trash Drop Ring Liner Square - Black
10829
5
Corner Guard - 1.25in - Pewter
x0032
2
Hot Rolled Steel Casing - Pewter
Shelving
10149
2
DT Lid shelf Wall Mounted
10176
1
Rolling Pastry Tray Rack
10222
1
Wire Shelf Grid at Sink
10416
9
Workroom Wire Shelving
10462
9
Workroom Wire Shelving Posts
10698
1
Mop Rack with 3 Holders
10838
1
Rolling Wire Cart for 3 Comp Sink
Solid Waste Handling Equipment
11070
1
Dishwasher Sanitizer

Comments

Rev Date
2
2/22/12

Revision Schedule
By
Description
HVAC/Sign Revisions

SB
SB
SB
SB
SB
SB
SB
GC
SB
SB
SB
SB
VD
SB
VD
SB
SB
SB
SB
SB
SB
VD
SB
SB
VD
VD
SB
SB
SB
SB
SB
SB
VD
SB
SB
SB
SB
SB
SB
SB
SB
SB
VD
VD
VD
SB
SB
SB
SB
SB
OPS
SB

719 East Valley Road


Basalt, Colorado 81621
Eagle County

Design ID

Site Schedule
Responsibility

Project Address:

x0018
2
Food Service Equipment
10020
1
Furniture & Accessories
10065
3
Other Site Development
10050
1
10052
1
Site Furnishings
10042
2
10046
1
12139
3

Description

Highway 82 & Willits

Count

Project Name:

Design ID

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

Sheet Title:

Schedules
Scale:

Sheet Number:

I-601

11403

Y:\Architectural Projects\12\3\XA12-311\5 CURRENT DRAWINGS\2 REVIT\1 Central File\Hwy 82 & Willits.rvt

Finish - Wall Base


Responsibility

457' - 4 3/4" Tile Base - Black - 6x12in 150x305mm

SB

x0026

382 SF

x0027

611 SF

Design ID
Length
Wall Finishes - Coverings
12173
142' - 9"
Chair Rail - 4in (100mm)
12247

VD

x0019

140' - 8 1/2" Vinyl - Wall Covering - Honey Brown


Woven Pattern - 36in (915) AFF
1' - 2"
Blackout Film

GC

x0031

8' - 6"

VD

Trim - 4in

VD

11957
11962

3
1

Comments

11977

Grout Specification 008: Mapei 10 - Black;


Laticrete 45 - Raven

12007
12008

2
1

Comments
See Casework Finish Schedule for
Material
Flat bar detail to be provided by General
Contractor
Mnfr: 3M 1st surface Black vinyl. Apply film
to entire window
Finish to match chair rail

12011

12019
12023
12032

1
1
1

12033
12034
12043
12057
12078

1
1
3
1
1

12080
12087

4
1

12096
12098
12100

1
2
5

12367
12472

1
1

12516
12640
12780

1
1
1

12816
12845
12854
13355

20
14
2
1

13391

13646

x0007
x0008

1
1

x0009
x0013

1
1

x0014

x0020

x0021

Fixed Casework
12028
12050
12363
12473
13191
13331
x0010

Color Code
Name
x0022
Paint - Bleeker Beige
x0023
Paint - Copley Gray
x0024
Paint - Monterey White

1
2
2

Finish - Wall Treatment (Area)


Description
Responsibility
Comments
Plastic - Fiberglass Reinforced Panel GC
White
Tile - Seventh Inning Stretch - 4x8in
SB
Mnfr: Paint By Numbers. Item #WT07
"Seventh Inning Stretch". See elevations,
sheet I-401, for gloss or satin designation
Tile - Backbar - 2x8in
SB
Mnfr: Design and Direct Source. American
QuarryCollection - Lustrous. Color: Pure

Finish - Wall Treatment (Length)


Description
Responsibility

2
2
3

11937
11945
11956

x0025 not used

Design ID
Area
11469
1119 SF
1

Description

Finish - Paint
LRV
Responsibility
Comments
7
GC
Benjamin Moore; HC-80
7
GC
Benjamin Moore; HC-140
7
GC
Benjamin Moore; HC-27

Casework Schedule
Responsibility

CW Finish - NCS Heritage "Steel Patina"

2
1
2
1
1
2
1

x0011
1
x0012
1
x0015
1
x0016
1
x0017
1
Furniture & Accessories
12335
2
12376
3

Corbel Support - 24in


Espresso Machine Pump Mount - 10x10in
Cabinet - Upper Cubby - 28x16x15in
700x405x375mm
Countertop - Hand Sink Stainless - 15in
380mm
Countertop - Trash Solid Surface - 15in
380mm
Cabinet - Warming Go Cart - 29in 735mm
Cabinet - 12in 305mm
Cabinet - Upper Cubby - 28x16x28in
700x405x720mm
Panel - Cup Dispenser
Condiment Cart Top Solid Surface - 59in
1500mm
Cabinet - Upper Cubby - 24x16x21in
610x405x535mm
Cabinet - Sink or Ice Bin - 24in 610mm
Condiment Cart Pan - 38x11in
965x280mm
Countertop - POS Solid Surface - 80in
2030mm
Condiment Cart Base - 59in 1500mm
Condiment Cart Sugar Dispenser SST
Countertop - Warming Solid Surface - 30in
760mm
DT Counter Support Panel - 6in 150mm
Cabinet - Variable to 36in 915mm
Cabinet - POS - 29in 735mm
Cabinet - Espresso - RH - 14in 355mm
Countertop - DT POS Solid Surface - LH Variable to 78in 1980mm
Cabinet - 15in 380mm
Cabinet - DT Espresso with Cubby - LH 20in 510mm
Cabinet - with Drawer - 15in 380mm
Cabinet - Brew Grind - 24in 610mm
Espresso Countertop Support Leg
Stainless
Merch Feature Cube Freestanding Tall
Countertop - Warming with Back Bumper
Stainless - 29in 735mm
Cabinet - Reserve Tower - LH
Newspaper Stand 4 Tier - 39in
Countertop - Brew Grind Work Sink and
Trash Solid Surface - LH - 117in 2970mm
French Cleat - Variable to 96in 2440mm
Soffit - Light Valance - 96x2in 2440x50mm
Merch Feature Cube Freestanding Short
Countertop - Reserve Clover Handoff Solid
Surface - LH
Cabinet - DT POS Upper Cubby - 32in
815mm
Cabinet - Reserve Clover with Drawer 12in 305mm
Cabinet - Upper Cubby - Customx16x15in
Countertop - DT Espresso Sideline Solid
Surface - LH - Custom
Fit Kit - Back Splash
Countertop - Reserve Sideline Solid
Surface - Custom
Countertop - Espresso Rinse Sink and Ice
Bin Solid Surface - LH
Countertop - CBS Solid Surface - LH - 79in
2005mm
Countertop - Solid Surface - Variable to
36in 915mm

Corian
Back Bar Countertops

VD
VD
VD

Condiment Cart Top


VD
Espresso Countertop, Clover Countertop
VD
Front Bar Countertops
VD
VD
VD

POS Counterop
Fabric
Banquette Seat
POS Finish Panels
Hafele - #102.81.620
Drawer, Cabinet Pulls

VD
VD
VD
VD
VD

VD
VD
VD
VD
VD
VD
VD
VD

Corian

Backbar

CP0020

Corian

Cafe

CP0020

Corian

Frontbar

CP0020

Corian

Frontbar

CP0020

Corian

Frontbar

CP0020

C 2011 Starbucks Coffee Company

Cafe
Frontbar

Starbucks Coffee
Company
2401 Utah Avenue South
Seattle, Washington 98134
(206) 318-1575

Plastic Laminate - Medium Tone


Brown with Grain

Plastic Laminate

Backbar

Plastic Laminate - Black


Plastic Laminate - Black

Plastic Laminate
Plastic Laminate

Frontbar

Hot Rolled Steel


Hot Rolled Steel

Steel
Steel

Cafe
Backbar

Hot Rolled Steel


Stainless Steel - #4 Brushed 16ga
SST
Hot Rolled Steel

Steel
Steel

Cafe
Backbar

Steel

Cafe

MT0011

Wood

Cafe

WD0001

Wood
Wood

Frontbar
Cafe

WD0016
WD0001

Wood

Frontbar

WD0001 Live Edge

Espresso, Foodcase Finish Panels


Exterior Custom Bench

Wood - Warm Brown Dark Tone


Distressed
Wood - Honey Brown Medium Tone
Wood - Warm Brown Dark Tone
Distressed
Wood - Warm Brown Dark Tone
Distressed
Wood - Honey Brown Medium Tone
Wood - Teak or Ipe Hardwood

Wood
Wood

Frontbar
Exterior
Seating

WD0016

Hand Off Finish Panels

Wood - Honey Brown Medium Tone Wood

Frontbar

WD0016

Espresso, Bar Top Cap

VD
GC
VD

Hafele #102.81.620

Clover Finish Panels


Community Table

Not provided by Casework vendor

Composite - Dark Grey with


Recycled Glass
Composite - Dark Grey with
Recycled Glass
Composite - Dark Grey with
Recycled Glass
Composite - Dark Grey with
Recycled Glass
Composite - Dark Grey with
Recycled Glass

Comments

Hafele - #102.81.620

Wall End Cap


Wood
Chair Rail

VD
VD
VD

VD
VD
SB
VD

Finish
Code

Material/Finish

Fabric
Fabric

Corner Guards
Hand Sink, Warming Countertop

VD
VD

Description

Antique Black
Antique Black

Plastic Laminate
Backbar Casework Exterior, Backbar Upper
Cubbies, Condiment Cart, POS, Safe
Cabinet
Core Casework Interior
POS, Frontbar Cabinet Sides
Steel
Banquette Metal Leg
Bar Panel Trim, Coffee Shuttle Shroud

VD

SB
VD

Zone

Comments

L-0016
L-0016

These Drawings and Specifications are confidential


and shall remain the sole property of Starbucks
Corporation, which is the owner of the copyright in
this work. They shall not be reproduced (in whole
or in part), shared with third parties or used in any
manner on other projects or extensions to this
project without the prior written consent of
Starbucks Corporation. These drawings and
specifications are intended to express Design Intent
for a prototypical Starbucks store (which is subject
to change at anytime) and do not reflect actual site
conditions. Neither party shall have any obligation
nor liability to the other (except as stated above)
until a written agreement is fully executed by both
parties.

Miscellan
eous
Finish
PL0014

MT0011
MT0011;
MT0028
MT0011

Architect of Record

5209 Lake Washington Blvd NE, Suite 200


Kirkland, WA 98033
t: 425 827 2100 | f: 425 828 6899 | www.fhoarch.com

Rev Date
1
12/4/12

Revision Schedule
By
Description
Review Revision

Coordinate final wood selection with DM. GC to


use sealer best suited for cold weather climate.
Confirm with construction manager

Not provided by Casework vendor

VD
VD
VD
VD

Based on ID #11902
Based on ID #13023

VD
VD

Based on ID #12073
Based on ID #13327

VD

Based on ID #12771

VD

Based on ID #11979

VD

Based on ID #12016. Remove backsplash

Panel - POS - 29in 735mm


Panel - POS Bridge for Safe - 22x27in
560x685mm
Merch Bay Unit Back Panel Solid
Panel - POS - 22in 560mm
Merch Bay Unit Metal Mesh End Panels
Merch Bay Unit
Diewall - Reserve Top Cap Customer Bar LH
Panel - Reserve Pass Thru - LH
Diewall - Reserve Pass Thru - LH
Diewall - Espresso Top Cap - LH - Custom
Panel - Espresso - LH - Custom
Diewall - Espresso - LH - Custom

VD
VD
SB
VD
SB
SB
VD

Not provided by Casework vendor


Not provided by Casework vendor
Based on ID #13358

VD
VD
VD
VD
VD

Based on ID #13321
Based on ID #13304
Based on ID #12766
Based on ID #12762
Based on ID #12765

Floor Basket and Stand - Short


Floor Basket and Stand - Tall

SB
SB

Not provided by Casework vendor


Not provided by Casework vendor

Not provided by Casework vendor

719 East Valley Road


Basalt, Colorado 81621
Eagle County

11142
11155
11902

11917

Length

Description

Location

11915

Design ID

Count

Project Address:

Design ID

Highway 82 & Willits

Finish - Floor Treatment


Description
Responsibility
Comments
Concrete Stain - Light Grey
GC
Based on ID #11377. Mnfr: Seal Source
International. KromaPolish, color: Steel
Gray. www.sealsource.com

Project Name:

Design ID
Area
x0034
1970 SF

Store #:

19548

Project #:

57194-001

Concept:

Heritage

Palette:

Steel Patina

Issue Date:

11/19/12

Design Lead:

Melissa Bodway

Checked by:

3/4/2013 1:00:47 PM

Sheet Title:

Schedules
Scale:

Sheet Number:

I-602