Professional Documents
Culture Documents
12.
12.1.
6012-71 Specifications
Stabilization
Stability Accuracy
Azimuth Motor
Level Motor
Inertial Reference
Gravity Reference
AZ transducer
-15 to +115
+/- 35
Azimuth
Unlimited
Elevation Pointing
Pitch
Yaw
Turning rate
Headway
Up to 50 knots
Heave
0.5G
Surge
0.2G
Sway
0.2G
12-1
Pitch
10 Fixed
Mounting Height
Diameter
1.47 m / 58"
TX Gain
RX Gain
C-band Feed
Type
Cross Pol Isolation
Co-Pol Isolation
NA
Polarization
Polarization Control
180 degrees
3.400-4.200 GHz
5.850-6.725 GHz
12-2
58 dBm
15K to 35K
Power requirements
Current (typical)
350 mA (typical)
Conversion gain
55 dB min, 70 dB max
5 kHz to 25 kHz
5.15 GHz
LO Radiation
-60 dBm
Image Rejection
40 dB min
+15 dBm
IP 3 (typical)
+25 dBm
Output Connector
N Connector
Impedance
50 Ohm
Input Flange
CPR-229
Input Power
Power consumption
Output Flange
WR-137
Input Connector
N Connector
950-1525700 MHz
L.O. Frequency:
1.5:1
44 dBm (25W) 46 dBm (40W)
Reference Frequency
-10 to +5 dBm
10 MHz
M&C Options
RS 232, RS 485
Step attenuator
0,4,8,12 dB
Alarms
12-3
Voltage
24 VDC, 150W
Wattage
150W (total)
Current Capacity
13.0A (total)
IPX7
Operating Temperature
-30C to +60C
Storage Temperature
-40C to +60C
Humidity
Altitude
Vibration
IEC 68-2-64
Shock
Connector
RJ11
Input Voltage
Min
4.75VDC
Typ
5.0VDC
Max
5.25VDC
GGA, GLL
Refresh Rate
1s
RF DC Power (J19)
USB (J5)
M16 (F)
Mini USB
RJ-11
DA-15S
L-Band (J16)
F-Connector
RF M&C (J7)
DE-9S
Feed (J10)
DB-25S
DE-9S
Serial (J14)
DE-9S
Coax Switch
LNB-A (J1)
SMA
LNB-B (J2)
SMA
SMA
Configurable from GUI
Ethernet (x2)
12-4
Status LEDs
PCU Status
Modem Status
Input RF Level
Output RF Level
Sensitivity
Bandwidth (3dB)
150 KHz
Interfaces
Modem/MXP M&C Interface
Network Interface
User Interface
DA-15P
Home
DE-9S
AZ
DA-15S
EL
DA-15S
CL
DA-15S
Status LEDs
CL Drive
Yes
EL Drive
Yes
Az Drive
Yes
MDE Status
Yes
Interface Connections
Connection
Power Requirements
ADE
12-5
Standard
Material
DIVINYCELL H100
Size
Diameter
2.05m / 80.8"
Height
0.55m / 21.75 in
Hatch Size
Radome Weight
RF attenuation
Typical 0.5 dB
Withstand relative average winds up to 56m/sec (125 MPH)
from any direction.
IP 56
Wind:
Ingress Protection Rating
ADE Environmental Conditions
Temperature Range (Operating)
Humidity
100% Condensing
Wind Speed
Solar Radiation
Spray
Icing
Rain
Corrosion
Mechanical Conditions
Systematic Vibration
Amplitude (single peak)
Acceleration
Frequency Range
5.0 millimeters
2.0 G (20m/s2)
1Hz - 150Hz
II
III
Number of Cycles
3 each direction
Directional Changes
12-6
Shock (Bump)
Peak Accel., m/s2
250
Duration, ms
Number of Cycles
Directional Changes
Transit Conditions
Drop (Transit Shock)
Test Level
Sea Salt
5 percent solution
12-7
MXP
Synchro Interface
Connectors
Input Voltage Level
Synchro Ratios
Impedance
SBS Interface
Connectors
Input Voltage Level
Interface
Polarity
Ratio
Impedance
NMEA Interface
Connections
Rx Sentence Format
Tx Sentence Format
0 to 40 degrees C
Up to 100% @ 40 degrees C, Non-Condensing
0 to 40 degrees C
Up to 100% @ 40 degrees C, Non-Condensing
Regulatory Compliance
Survival Shock and Vibration
Operational Shock and Vibration
IEC-60721, MIL-STD-901D
Operational: IEC-60945, Survival: IEC-60721 and MIL-STD
901D
MIL-STD-167-1
ETSI EN 301 843-1 V1.4.1 (2004-06)
ETSI EN 301 489-1 V1.4.1 (2002-08)
ETSI EN 300 339 (1998-03)
IEC EN 60945:1997
ETSI EN 301 428-1 V1.3.1 (2006-02)
ETSI EN 302 340 V1.1.1 (2006-04)
IEC EN 60950-1:2001 (1st Edition)
RoHS
Green Passport
47 C.F.R. 25.221
47 C.F.R. 25.222
47 C.F.R. 25.138 (FSS)
Bluetooth
12-9