You are on page 1of 2

d

an rs
l
to
o
tr mo P @
n
o ect 0H HP
5
ot to 3 r 2
V
o
up 0V 600
48 @

th
wi of
ed ro
pp onp ion
i
u
i
t
eq los ina rs
3
b
p
e ize
t
m
x
e co tar S
S
to
0
e
z
Si

is
th it
e f
ur l o
!
al
s eds
ne
t
le
a
d
l A AY! 000
l
Ca TOD 7.9
26
6.
1
2

s
ol
to d to rip
no uire e t
req hang s!
exc dule
mo

2
KZ
P
s
r
e
Us elle trip
o
M g-in s
plu dule
mo

l
al int 6
m
s tpr x
10
o
fo 14 x
ly
on

Introducing the compact footprint


combination starter with modular,
interchangeable trip blocks for Size
0 through Size 3 explosionproof
combination starter requirements.
One frame size to control and protect motors up
to 30HP @ 480V or 25HP @ 600V
Universal enclosure and starter assembly for
Size 0 through Size 3 applications
Eleven different plug-in modules range from
fractional to 30HP
Exchanging trip modules does not require tools
or re-wiring.
Units are available in both AC and DC, full
voltage non-reversing and full voltage reversing
models up to 42 amps continuous current
rating.
ATEX version available, consult factory

Contact Us Today! Call For A Free Quote.

216.267.9000
www.adalet.com

10

EXPLOSIONPROOF COMBINATION MOTOR STARTER


WITH MODULAR TRIP BLOCKS
Compact, universal enclosure design for explosionproof
combination starters Size 0 to Size 3 Controls & protects
motors up to 30HP (@460V) and 25HP (@600V)

Certifications

14

Class I, Division 1, Group D


Class II, Division 1, Groups EFG
Class III
Type 4X / 7 / 9
UL 1203
CSA C22.2 No. 25 & 30
UL 50

Adalet explosionproof enclosures are the industry


standard for housing and protecting motor control
components in hazardous locations. Built for a
variety of explosionproof applications, Adalet motor
control enclosures provide application flexibility for
many installations. Using Moellers PKZ2 plugin trip modules, Adalet can now provide a much
smaller, universal explosionproof enclosure for
Size 0 through Size 3 explosionproof combination
starter requirements.

Using one frame size to control and protect motors


up to 30HP @ 480V or 25HP @ 600V, the Adalet
explosionproof combination motor starter provides
a universal enclosure and starter assembly for
Size 0 to Size 3 applications. The universal trip
modules allow the enclosure size to be decreased
from our standard offering, creating a more
compact and lighter weight assembly. Eleven
different plug-in modules range from fractional to
30HP. Exchanging trip modules does not require
tools and will not require re-wiring.

Units are available in both AC and DC, full voltage


non-reversing and full voltage reversing models
up to 42 amps continuous current rating. FVNR
versions are mounted on standard 35mm DIN rail.
FVR versions are supplied with factory mounted
and wired disconnect and mechanically interlocked
contactors.
The Adalet explosionproof enclosure internal
dimensions are 10W x 14H x 6D and include
many standard features.

Trip Module with HAND - AUTO Feature


Adjustable Thermal
Range set to Motor
FLC (1)
Catalog Number

Adjstable Trip Setting


Current of Magnetic
Trips (1)

Standard enclosure features include

Typical Maximum Horsepower


Typical Three Phase
[HP]

[A]

[A]

0.4 - 0.6

5-8

NO

NC

XCE 101406-N4-PK2-1

0.6 - 1

8 - 14

See Note Below

XCE 101406-N4-PK2-1.6

1 - 1.6

14 - 22

See Note Below

XCE 101406-N4-PK2-2.4

1.6 - 2.4

20 - 35

1-1/2

XCE 101406-N4-PK2-4

2.4 - 4

35 - 55

XCE 101406-N4-PK2-6

4-6

50 - 80

1-1/2

1-1/2

XCE 101406-N4-PK2-10

6 - 10

80 - 140

7-1/2

XCE 101406-N4-PK2-16

10 - 16

130 - 220

10

10

XCE 101406-N4-PK2-25

16 - 25

200 - 350

7-1/2

7-1/2

20

25

XCE 101406-N4-PK2-32

24 - 32

275 - 425

10

10

20

XCE 101406-N4-PK2-40

32 - 42

350 - 500

10

15

30

XCE 101406-N4-PK2-0.6

200V

240V

480V

Auxiliary Contacts
600V

See Note Below

* - Horsepower ratings shown in the table are for reference only.


The final selection of the manual starter depends on the actual motor full load current and service factor on the motor nameplate.
Overload should be set at motor FLA full load current and is calibrated to 1.15 S.F.
Specified values to NEC table 430-150.
(1) - All Types have adjustable dial for setting motor full load current. Trip current is 125% of set value. For motors with a service factor (SF) of 1.0,
set dial to 90% of motor full load current.

4801 W. 150th St., Cleveland, oh 44135

216.267.9000

Universal enclosure for Size 0 to Size


3 explosionproof combination starters
Watertight gasket
Hinged cover
Disconnect handle
Start & stop pushbuttons
Mechanical reset button
Drilled & tapped conduit entries
Stainless Steel Cover Bolts
Combo Starter
100VA Transformer
(2) plugged NPSM (for future use)
Wiring and standard conduit entries
Two separate sets of current limiting
main contacts provides protection
against damage under fault conditions
Extensive range of accessories and
options

www.adalet.com

You might also like