You are on page 1of 41

Industrial Services Center - Datco

78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt


Web Site: http://www.datcoegypt.com

Infrared Thermal Imaging


Inspection Report-Production
Lines

1/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Max

24.6

Min

23.8

Average

24.1

C
28.5

Li1

Parameters
Emissivity
Refl. temp.

15/12/2015 01:54:18 PM

0.95
20 C

Note
Heat Exchanger Panel

IR_3231.jpg

FLIR E50

15/12/2015 01:54:18 PM

DC_3232.jpg

Text annotations
Description of analysis & observation

2/41

Normal conditions are observed, where the production line 1 stopped.

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

22.3
49025354

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Max

28.6

Min

28.0

Average

28.4

Max

29.4

Min

28.0

Average

28.8

15/12/2015 01:57:27 PM

C
36.6

Parameters
Emissivity
Refl. temp.

0.95
20 C

Li2

Note
Feyer Panel

Li1

IR_3233.jpg

FLIR E50

15/12/2015 01:57:27 PM

DC_3234.jpg

Text annotations
Description of analysis & observation

3/41

Normal conditions are observed, where the production line 1 stopped.

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

24.9
49025354

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Max

30.3

Min

28.0

Average

29.1

15/12/2015 02:06:54 PM

C
38.2

Parameters
Emissivity
Refl. temp.

0.95
20 C
Li1

Note

IR_3249.jpg

FLIR E50

15/12/2015 02:06:54 PM

DC_3250.jpg

Text annotations
Description of analysis & observation

4/41

Normal conditions are observed, where the production line 1 stopped.

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

20.2
49025354

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Max

32.3

Min

30.6

Average

31.1

15/12/2015 02:22:10 PM

C
44.0

Li1

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note
Seasoning Loop 1

IR_3273.jpg

FLIR E50

15/12/2015 02:22:10 PM

DC_3274.jpg

Text annotations
Description of analysis & observation

5/41

Normal conditions are observed, where the production line 1 stopped.

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

29.4
49025354

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Max

31.4

Min

29.1

Average

29.8

15/12/2015 02:23:43 PM

C
45.2

Parameters
Emissivity
Refl. temp.

0.95
20 C

Li1

Note
Seasoning Loop 2

IR_3275.jpg

FLIR E50

15/12/2015 02:23:43 PM

DC_3276.jpg

Text annotations
Description of analysis & observation

6/41

Normal conditions are observed, where the production line 1 stopped

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

27.1
49025354

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Max

30.6

Min

27.9

Average

28.6

15/12/2015 02:25:11 PM

C
42.5

Parameters
Emissivity
Refl. temp.

0.95
20 C

Li1

Note
Seasoning Loop 3

IR_3277.jpg

FLIR E50

15/12/2015 02:25:11 PM

DC_3278.jpg

Text annotations
Description of analysis & observation

7/41

Normal conditions are observed, where the production line 1 stopped

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

26.6
49025354

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Sp1
Li1

15/12/2015 02:27:02 PM

C
32.2

25.6
Max

30.5

Min

27.3

Average

28.9

Parameters
Emissivity
Refl. temp.

0.95
20 C

Sp1

Note
Packing 1

Li1

IR_3279.jpg

FLIR E50

15/12/2015 02:27:02 PM

DC_3280.jpg

Text annotations
Description of analysis & observation

8/41

Normal conditions are observed, where the production line 1 stopped.

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

22.2
49025354

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Li3

Max

25.8

Min

23.3

Average

25.2

Max

25.9

Min

25.5

Average

25.8

Max

25.8

Min

25.6

Average

25.7

15/12/2015 02:02:40 PM

Li2

Parameters
Emissivity
Refl. temp.

C
30.5

Li3

0.95
20 C
Li1

Note
Main Oil Pump Panel

IR_3241.jpg

FLIR E50

22.0
49025354

15/12/2015 02:02:40 PM

DC_3242.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

9/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Max

28.5

Min

27.8

Average

28.2

Max

29.3

Min

26.2

Average

28.8

15/12/2015 02:04:43 PM

C
29.3

Li1

Li2

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note
Preparation Panel

IR_3247.jpg

FLIR E50

23.0
49025354

15/12/2015 02:04:43 PM

DC_3248.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

10/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Max

24.8

Min

24.4

Average

24.6

15/12/2015 02:08:48 PM

Parameters
Emissivity
Refl. temp.

C
34.2

Li1

0.95
20 C

Note
Intake Extension Panel

IR_3251.jpg

FLIR E50

22.1
49025354

15/12/2015 02:08:48 PM

DC_3252.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

11/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Li3

Max

26.7

Min

24.3

Average

25.9

Max

26.7

Min

26.4

Average

26.6

Max

26.3

Min

25.4

Average

26.0

15/12/2015 02:11:00 PM
Li3

Parameters
Emissivity
Refl. temp.

C
35.3

Li2

0.95
20 C

Note
Li1

+PC1-1A

IR_3253.jpg

FLIR E50

14.4
49025354

15/12/2015 02:11:00 PM

DC_3254.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

12/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Max

28.0

Min

27.1

Average

27.4

Max

26.9

Min

26.2

Average

26.7

15/12/2015 02:12:31 PM

Li2

Parameters
Emissivity
Refl. temp.

C
37.2

Li1

0.95
20 C

Note
Intake Extension Panel 2

IR_3257.jpg

FLIR E50

25.8
49025354

15/12/2015 02:12:31 PM

DC_3258.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

13/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Sp1
Li1

Li2

15/12/2015 02:15:57 PM

C
36.8

31.3
Max

33.4

Min

30.8

Average

32.2

Max

33.3

Min

31.1

Average

32.5

Sp1

Parameters
Emissivity
Refl. temp.

0.95
20 C

Li2

Note

Li1

Potato Preparation Panel

IR_3261.jpg

FLIR E50

24.6
49025354

15/12/2015 02:15:57 PM

DC_3262.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

14/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Li3

Max

26.5

Min

25.9

Average

26.2

Max

26.8

Min

26.1

Average

26.4

Max

26.5

Min

25.4

Average

26.0

15/12/2015 02:17:41 PM

C
34.6

Li3

Li2

Parameters
Emissivity
Refl. temp.

Li1

0.95
20 C

Note
M.O.P Panel

IR_3265.jpg

FLIR E50

24.1
49025354

15/12/2015 02:17:41 PM

DC_3266.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

15/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Max

30.7

Min

29.2

Average

29.7

Max

28.1

Min

26.5

Average

27.2

15/12/2015 02:17:59 PM

C
32.7

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note

Li2

M.O.P Panel
Li1

IR_3267.jpg

FLIR E50

24.3
49025354

15/12/2015 02:17:59 PM

DC_3268.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

16/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Li3

Li4

Max

24.3

Min

23.4

Average

23.7

Max

24.5

Min

23.2

Average

23.8

Max

24.8

Min

24.0

Average

24.4

Max

25.1

Min

24.1

Average

24.5

15/12/2015 02:19:56 PM

C
29.1

Li2
Li3

Li4
Li1

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note
Slice wash & Fryer Panel

IR_3269.jpg

FLIR E50

23.1
49025354

15/12/2015 02:19:56 PM

DC_3270.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

17/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Sp1
Li1

15/12/2015 02:20:17 PM

C
29.6

27.8
Max

26.8

Min

26.1

Average

26.4

Parameters
Emissivity
Refl. temp.

Sp1

0.95
20 C

Note
Slice wash & Fryer Panel
Li1

IR_3271.jpg

FLIR E50

20.1
49025354

15/12/2015 02:20:17 PM

DC_3272.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

18/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Li3

Li4

Li5

Max

39.0

Min

35.4

Average

37.0

Max

34.3

Min

31.7

Average

32.7

Max

31.1

Min

28.9

Average

29.9

Max

29.5

Min

27.8

Average

28.9

Max

32.6

Min

30.4

Average

31.7

C
39.2

Li4
Li3

Li1
Li5
Li2

IR_3281.jpg

Parameters
Emissivity
Refl. temp.

15/12/2015 02:28:43 PM

0.95
20 C

FLIR E50

21.3
49025354

15/12/2015 02:28:43 PM

Note
Packing 2

DC_3282.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

19/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Max

40.3

Min

31.6

Average

36.8

Max

47.9

Min

38.5

Average

42.6

15/12/2015 02:31:22 PM

C
44.4
Li1
Li2

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note
Seasoning Loop 4

IR_3283.jpg
15/12/2015 02:31:22 PM

Text annotations

FLIR E50

28.3
49025354

DC_3284.jpg

Description of analysis & observation

Raised temperature are observed on line (2).

Action / Severity

Monitor development and repair as necessary required for the Li (2). / low severity

Code / Fault

Four / Alert

Potential impact upon severity

Occur short circuiting/turn-to-turn faults.

Conditions Found/Deviation

Loose connections/poor contacts/rust/unbalanced loads/deteriorated internal contact/


overloading/overheating is of concern.

Physical inspection/Electrical testing/Remedy

The source of the raised temperature shall be investigated and eliminated by cleaning/tighten the
connection/inspection the internal component/change the component, if possible.

20/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Max

32.8

Min

27.8

Average

29.7

15/12/2015 02:33:02 PM

C
39.9

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note
Heat Exchanger 2

Li1

IR_3285.jpg

FLIR E50

25.0
49025354

15/12/2015 02:33:02 PM

DC_3286.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which is
an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

21/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements

Sp1

34.8

Sp2

36.1

Sp3

37.5

Li1

Max

35.6

Min

31.5

Average

33.5

15/12/2015 02:34:49 PM
Li1

Parameters
Emissivity
Refl. temp.

C
39.6

Sp1

0.95
20 C

Sp2

Sp3

Note
Heat Exchanger 3

IR_3291.jpg

FLIR E50

27.8
49025354

15/12/2015 02:34:49 PM

DC_3292.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which is
an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

22/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Sp1
Li1

15/12/2015 02:36:23 PM

C
39.1

22.9
Max

23.7

Min

21.8

Average

22.4

Parameters
Emissivity
Refl. temp.

0.95
20 C

Sp1

Note
3
Li1

IR_3297.jpg

FLIR E50

20.5
49025354

15/12/2015 02:36:23 PM

DC_3298.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

23/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Max

24.1

Min

23.5

Average

23.8

Max

23.9

Min

23.8

Average

23.9

15/12/2015 02:38:13 PM

C
31.8

Parameters
Emissivity
Refl. temp.

Li2

0.95
20 C

Li1

Note
Preparation Line 3

IR_3301.jpg

FLIR E50

15.2
49025354

15/12/2015 02:38:13 PM

DC_3302.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

24/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Li3

Li4

Max

31.3

Min

30.6

Average

30.9

Max

30.8

Min

27.1

Average

29.5

Max

35.7

Min

33.4

Average

34.5

Max

35.4

Min

28.6

Average

32.0

15/12/2015 02:38:44 PM

C
35.3

Li2

Li4
Li3

Li1

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note
Preparation Line 3

IR_3305.jpg

FLIR E50

25.4
49025354

15/12/2015 02:38:44 PM

DC_3306.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

25/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Max

37.9

Min

29.8

Average

34.4

Max

36.6

Min

28.7

Average

32.1

15/12/2015 02:40:44 PM

C
40.0

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note

Li2

M.O.P Panel

Li1

IR_3311.jpg

FLIR E50

25.6
49025354

15/12/2015 02:40:44 PM

DC_3312.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

26/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Max

37.9

Min

28.7

Average

34.4

15/12/2015 02:40:33 PM

C
39.0

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note
M.O.P Panel

Li1

IR_3309.jpg

FLIR E50

25.6
49025354

15/12/2015 02:40:33 PM

DC_3310.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

27/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Max

18.5

Min

15.4

Average

16.8

Max

21.2

Min

19.9

Average

20.5

15/12/2015 02:42:35 PM

C
29.6

Parameters
Emissivity
Refl. temp.

Li2

0.95
20 C

Note
Slice wash & Fryer Panel

Li1

IR_3313.jpg

FLIR E50

14.3
49025354

15/12/2015 02:42:35 PM

DC_3314.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

28/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Li3

Li4

Max

28.9

Min

27.9

Average

28.3

Max

28.7

Min

27.5

Average

28.2

Max

28.8

Min

27.0

Average

27.8

Max

28.7

Min

27.4

Average

28.0

15/12/2015 02:43:15 PM

C
34.2
Li1
Li2

Li3

Li4

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note
Slice wash & Fryer Panel

IR_3315.jpg

FLIR E50

26.2
49025354

15/12/2015 02:43:15 PM

DC_3316.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

29/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Max

42.5

Min

41.3

Average

42.1

Max

43.0

Min

35.6

Average

38.7

15/12/2015 02:46:12 PM

C
41.8
Li1

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note

Li2

Seasoning Loop 5

IR_3317.jpg

FLIR E50

27.0
49025354

15/12/2015 02:46:12 PM

DC_3318.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

30/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Max

33.3

Min

28.2

Average

31.2

Max

33.5

Min

29.5

Average

30.8

15/12/2015 02:47:36 PM

C
34.0

Li1

Parameters
Emissivity
Refl. temp.

0.95
20 C

Li2

Note
Seasoning Loop 6

IR_3319.jpg

FLIR E50

24.9
49025354

15/12/2015 02:47:36 PM

DC_3320.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

31/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Max

23.4

Min

22.9

Average

23.1

Max

23.5

Min

22.6

Average

22.8

15/12/2015 03:02:51 PM

C
28.7

Li1

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note

Li2

Packing 3

IR_3341.jpg

FLIR E50

19.5
49025354

15/12/2015 03:02:51 PM

DC_3342.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

32/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Max

30.2

Min

29.2

Average

29.6

15/12/2015 02:50:17 PM

C
30.5

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note

Li1

Oven RPS

IR_3321.jpg

FLIR E50

25.2
49025354

15/12/2015 02:50:17 PM

DC_3322.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

33/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Li3

Li4

Li5

Max

29.9

Min

29.4

Average

29.7

Max

29.9

Min

29.5

Average

29.7

Max

32.0

Min

30.9

Average

31.6

Max

31.5

Min

31.0

Average

31.3

Max

30.9

Min

30.4

Average

30.7

0.95
20 C

C
31.9

Li1
Li2

Li3
Li4

Li5

IR_3323.jpg

Parameters
Emissivity
Refl. temp.

15/12/2015 02:50:29 PM

FLIR E50

24.8
49025354

15/12/2015 02:50:29 PM

Note
Oven RPS

DC_3324.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

34/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Li3

Max

31.2

Min

29.8

Average

30.4

Max

31.6

Min

30.5

Average

31.0

Max

38.0

Min

35.3

Average

36.7

15/12/2015 02:50:45 PM

Li1

Parameters
Emissivity
Refl. temp.

C
41.7

Li2

Li3

0.95
20 C

Note
Oven RPS

IR_3325.jpg

FLIR E50

26.0
49025354

15/12/2015 02:50:45 PM

DC_3326.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

35/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Max

29.1

Min

28.8

Average

29.0

15/12/2015 02:52:45 PM

C
33.6

Parameters
Emissivity
Refl. temp.

0.95
20 C

Li1

Note
Process Control Panel

IR_3327.jpg

FLIR E50

27.9
49025354

15/12/2015 02:52:45 PM

DC_3328.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

36/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Li3

Li4

Max

29.4

Min

29.1

Average

29.2

Max

29.2

Min

29.0

Average

29.1

Max

29.3

Min

28.9

Average

29.1

Max

31.3

Min

30.4

Average

30.9

15/12/2015 02:52:57 PM

C
33.9

Li2

Li1

Li3

Parameters
Emissivity
Refl. temp.

Li4

0.95
20 C
IR_3329.jpg

FLIR E50

26.4
49025354

15/12/2015 02:52:57 PM

DC_3330.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

37/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Li3

Max

34.6

Min

33.0

Average

33.6

Max

44.3

Min

39.6

Average

42.0

Max

34.0

Min

31.3

Average

32.2

15/12/2015 02:53:40 PM

Li1

C
59.3

Li2

Li3

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note
Process Control Panel

IR_3333.jpg

FLIR E50

26.5
49025354

15/12/2015 02:53:40 PM

DC_3334.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed as the temp. diff. on the midle component is more
loaded than other component otherwise temp. diff. for each component is an
acceptable.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

38/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Max

33.6

Min

29.2

Average

31.1

Max

31.7

Min

28.7

Average

30.4

15/12/2015 02:53:51 PM

C
40.2

Li1

Li2

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note
Process Control Panel

IR_3335.jpg

FLIR E50

27.8
49025354

15/12/2015 02:53:51 PM

DC_3336.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which is
an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

39/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Li1

Li2

Max

32.8

Min

31.1

Average

32.2

Max

30.6

Min

29.3

Average

30.2

15/12/2015 02:56:59 PM

C
33.1
Li1

Parameters
Emissivity
Refl. temp.

0.95
20 C

Li2

Note
Seasoning Loop 7

IR_3337.jpg

FLIR E50

23.9
49025354

15/12/2015 02:56:59 PM

DC_3338.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

40/41

Infrared Thermal Imaging Inspection Report


Report Author: Sherif Mounir Ahmed
Mobile: +2 012 - 85 711 000
Email: sherif.mounir@datcoegypt.com

Industrial Services Center - Datco


78 Al Moultka Al Araby st., Sheraton, 11361 Cairo - Egypt
Web Site: http://www.datcoegypt.com
Measurements
Sp1
Li1

15/12/2015 02:59:59 PM

C
34.5

28.9
Max

29.7

Min

28.3

Average

28.9

Parameters
Emissivity
Refl. temp.

0.95
20 C

Note

Sp1
Li1

Packing 4

IR_3339.jpg

FLIR E50

23.7
49025354

15/12/2015 02:59:59 PM

DC_3340.jpg

Text annotations
Description of analysis & observation

Normal conditions are observed, the temp. diff. is less than 5C as shown in the
above mentioned measurements table between the max. and the min. spots, which
is an acceptable diff.

Action / Severity

No Action required / No severity

Code / Fault

Normal condition / No fault

41/41

Infrared Thermal Imaging Inspection Report