You are on page 1of 11

Opvaskemaskine

LF 65 ITX

PV IMPORT a/s GRSDALSVEJ 20 8800 VIBORG

www.fagor.com

N5877

Notes on PROGRAMMES:
C Alternate wash
RE1 Electronic regeneration

b5

b4

b3

b2

b1

b0

OUTPUTS

MOTOR DISTRIBUTOR CYCLE

DETERGENT / RINSE AID

OTHERSS

BASIC FUNCTION

b6

PPROGRAMME STEP

b7

TIME ADJUSTMENT

REGENERATION VALVE

FILL VALVE

RUNNING

QUICK 55C / EXPRESS

MIXED 50C

ECO 50C

NORMAL/AUTOMATIC 55 or 65C-72C*

INTENSIVE 70C

PROGRAMME STEP

PREWASH

FAGOR

DRAIN PUMP

MOTOR FAN

HEATING ELEMENT

WASH PUMP

USAGER

CONDITION FOR STEP

RELIABILITY

ENDURANCE

FUNCTIONS

R
AS
AL
EX
NEX
RFT
TUR

Temperature mantained at -3
Dirty water
Clean water
Top Express runs if selected
NO Top Express runs if Express is not selected
Water cloudiness measured in last second
Water cloudiness measured in last second

F=50Hz
TDS1 = 0,84 sec
TDS2 = 1,25 sec
TDS3 = 1,67 sec
TDS4 = 2,10 sec

DS2
DS3
DS1
DS4

Lower
Open
Closed
Closed
1/2 Open

F=60Hz
TDS1 = 0,70 sec
TDS2 = 1,04 sec
TDS3 = 1,40 sec
TDS4 = 1,67 sec
Upper
Closed
Open
1/2 Open
Closed

PREWASH

C
C
C
C
C
C

55 C and 10 min

TUR
AS
AS
AS
AS

TUR
AS
AS
AS
AS

75 C
1 min
15 sec
DS3
MN empty
10 sec
20 sec
DS3
MN empty
10 sec
20 sec

TUR
AS
AS
AS
AS

DRAIN

FILL

WASH

SENSOR L.
DRAIN

DRAIN

WASH
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49

AS
AS
AS
AS

AS
AS
AS
AS

AS
AS
AS
AS

DS3
20 sec
15 sec
MN full
DS3
20 sec
15 sec
MN full
1 min
75 C

NEX
EX
RE1 RE1 RE1 RE1 RE1

15 min
5 min
10 min
3 min
DS3
MN empty
10 sec
40 sec
20 sec

NEX

RE1 RE1

RINSE I
50
51
52
53
54
55
56
57
58

2 min

RE1 RE1

52 C and 22 min

RE1 RE1 RE1 RE1 RE1

C
C
C
C
C
C
C
C
C

68 C and 12 min
65 C and 17 min
55 C and 12 min
52 C and 15 min
55 C and 10 min
40 C and 5 min

AS
AL

22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49

C
C
C
C
C
C

FILL

FILL

WASH

DRAIN

I
DS3
20 sec
15 sec
MN full
6 min
DS3
MN empty
10 sec
20 sec

NEX
NEX
NEX
NEX
NEX
NEX
NEX
NEX
NEX

50
51
52
53
54
55
56
57
58

FILL
WASH
DRAIN

RINSE II
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78

DS3
20 sec
15 sec
MN full

20 sec

59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78

10 min
30 min
14 min
2 min
1 min

79
80
81
82
83

75 C
65 C and 8 min
55 C and 6 min

NEX
EX

40 C and 4 min

1 min
4 min
2 min
65 C
68 C
30 sec
DS3
MN empty

NEX

NEX

C
C
C
C
C
C
C
C
C
C

FILL

WASH

DRAIN

DRY
79
80
81
82
83

NEX

DRY

END OF PROGRAMME
84
85
86
87
88
89

C Fagor Electrodomesticos, S. Coop.

DS3
MN empty
20 sec
30 min
RESTART
STOP

2004

Si

84
85
86
87
88
89

DRAIN

END PROGR.

FOR INTENSIVE, AUTOMATIC AND MIXED PROGRAMMES THE CLOUDINESS SENSOR


MUST BE READ ON PREWASH. TO DECIDE WHETHER TO USE THE SAME WATER
FOR WASHING. ON AUTOMATIC IT WOULD ALSO WASH AT 55 OR 65.

RFT

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

HEATING ELEMENT:
The heating element is connected until the step condition temperature setting is reached. It is then switched off.
If the step condition includes another type of condition (e.g. time) apart from a temperature setting:
.- when the temperature setting is reached, the heating element switches off.
.- except when R is indicated, in which case the temperature regulation is done with hysteresis.

RFT RFT

MN empty
30 sec
DS3
20 sec
15 sec
MN full
5 min
3 min
12 min

Strictly speaking, STOP is not a step condition. It means that the step counter is placed on hold.
Strictly speaking, RESTART is not a step condition. It means the step counter goes to O.

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

C
50s
50s Fill/drain position
10s
10s

Notes on STEP CONDITIONS:


DS1, DS2, DS3 and DS4 are the four preset stopping positions for the distributor.
They are all set as the position the distributor reaches 0.1 seconds after a single micro switch contact has opened,
and they are differentiated by the time this contact remains closed.
The nominal contct closing times preceding each stopping position are as follows:
The motor distributor completes a full turn in 15 seconds.

DATE:20-FEBRUARY-2004

PROGRAMMES

MN empty means the micro switch level is indicating empty (contact open).

FAGOR IT 2004 STANDARD-DELUXE

MN full means the level micro switch is indicating full (contact closed).

S A T

S A T

Look the elctronic card inthis position


to analyze this electric diagram:

NTC
R_RESISTANCE
M-WASH MOTOR
C_CONDENSER
IG_MAIN SWITCH
EB_DRAIN PUMP
TS_SAFETY THERMOSTAT 85
MVS_DRYING VENTILATOR
MD_DISTRIBUTOR MOTOR
SD_DISTRIBUTOR SIGNAL
MP_DOOR MICROSWITCH
MN_NORMAL MICRO
MS_SAFETY MICRO
EVR_REGENERATION VALVE
MPR_PRESSURE MICRO
DD/DT DOSIFIER FOR DETERGENT AND RINSE-AID
EVLL_WATER INTAKE VALVE
Ins_SALT SWITCH
InT_RINSE-AID SWITCH

J3

MN

10 9 8 7 6 5 4 3 2 1

NTC

MPR
3

Signal

J5

123

TS

J1

IG

3
MS

J2

CARD 2004
ELECTRON.IT

MVS

TUR. SENSOR

EVR

2006

EVLL

C Fagor Electrodomesticos, S. Coop.


SD

MP

S A T
www.fagor.com
N5876

S A T

DD / DT

lnT

lnS

906012558 [LF-65ITX] - FAGOR - 02-04-2007


Pos.

Reference

Description

2
2
3
3
4
5
7
8
10
11
11
14
16
16
16
16
17
18
19
20
21
23
24
25
26
29
32
38
41
42
43
43
44
45
49
51
55
56
57
59
60
61
62
69
70
72
73
77
77
80
81
82
83
86
90
91
92
93
95
96
97
98
99
100
103
105
106
107
111

V53B000T0
V53B000U6
VF9B000A5
VF9B000B1
LV0860500
V87B000C0
V66B000B5
VA9B000D3
VA9B000H7
VA9B000E9
VA9B000G1
V19C000D7
V53B000V2
V53B000W8
V53B000A0
V53B000C2
V19C000B6
V21B000B3
VE8A000M5
VC5A000E3
VC5A000F9
VE5A001F8
VE5A001G4
V09B000N3
V67C000B9
VF8A000Q4
V27M000D5
V72B000G9
V87A000E5
VF6A000G0
VC4B000A9
VC4B000B5
VF0000026
V64I000H5
VB3B000B1
LQ1A000A1
VH7A000I1
V77I000E6
VL4S000E2
VH2A000F5
VH2A000E9
VH2B000B8
VC5A000G5
LV0655100
LV0860300
V87A000S6
VG8A000U3
Z02K039A4
Z02K041A7
VH2A000H7
VH2B000F1
LV0655900
LV0655200
V24A000Z0
VI8I000F3
V36H000A6
V35A002A3
V23A000E0
VJ7A000N1
LV0861200
VC6A000D5
LV0656700
V87B000E1
VH6I000D0
V23I000C5
V12B001C9
VJ1A000J1
VC8B001A8
V99I000H1

EXTENSION
EXTENSION
GUIDE RAIL
GUIDE RAIL
MOTOR UNIT
SEAL
CATCH
BEARING
RACK GUIDE RAIL
END STOP
END STOP
COVER
SIDE PANEL
SIDE PANEL
SIDE PANEL
SIDE PANEL
EXTENSION
ADJUSTABLE FOOT
PAN
SEAL
FIXING
FILTER
FILTER UNIT
DOOR CLOSURE
DOOR
PLINTH
S.STE.CONTROL PANEL
DOOR SEAL
SEAL
SPRING
MOVING HINGE
MOVING HINGE
INSIDE DOOR
FEEDER
LOWER DOOR SEAL
BENDER
DRAIN PIPE
WATER INTAKE HOSE
DISTRIBUTOR
CAP
NUT
DECALCIFIER
SEAL
SEAL
NON-RETURN UNIT
SEAL
INNER PIPE
SCREW
SCREW
AIR BREAK UNIT
NUT
REED
SEAL
PAN PIPE
FILTER
SWITCH
POWER CABLE
MICRO
LEVELLING UNIT
PUMP UNIT
SUPPORT
WOBBLER
SEAL
CONDENSER
MICRO
HEATER UNIT
CUTLERY
HANDLE
DRAIN PUMP

From

Until

20-03-2006
20-03-2006

Pos.

Reference

Description

113
114
115
116
117
118
119
120
122
123
124
125
126
128
132
134
137
142
143
154
156
161
162
166
167
168
169
170
172
174
176
176
177
178
179
180
184
185
187
188
190
191
191
192
193
195
196
198
200
200
210
220
228
229
230
231
232
233
234
235
236
238
239
240
241
243
244
245
250
251
252

VC8B003A4
LV0860450
VH1A000N3
VE2A000J0
VH5A000B5
VD9A000L1
V58X000C8
VJ7A000L0
LV0655300
LV0656100
V23I000E6
VL1A000A1
VK9A000A8
LV0162600
VJ7A000P3
V54L001A4
V58X000D3
VE7B000A3
V09C000B0
V92B000C7
Z02K037A8
Z02K042A5
LV0656200
LV0654800
LV0653800
VE4A000G9
VE4A000H5
VA5A000I4
VJ1A000E2
VI6B000I4
V92B000A5
V92B000B1
VA5A000M8
LV0657100
LV0657200
V03E000A8
V19C000F9
V01M000B5
V19C000A0
LV0656300
VA5A000E1
VJ8A000N9
VJ8A000P1
VJ8A000M4
VC8A000M4
LV0655600
VC4B000C1
VF9B000C7
V28F011H0
V28F011I5
LV0657700
LV0657800
VE8A000N0
VJ1A000K7
VC4B000F8
VL8A000B2
VC4B000E2
V87B000B4
V87A000Z7
VK2A000C5
Z02K038A6
VH7A000H6
V21B000C9
V19C000C2
VC8B002A6
V87B000D5
V21B000I3
V21B000H8
LV0858700
VB3B000C7
LV0702200

FOLDING ADJUSTABLE
BSKT.WHEEL UNIT
LOWER BASKET
WHEEL
FUNNEL
CUTLERY
KEY
LEVER
O-RING
SUPPORT
MICRO
GRILLE
SUPPORT
SEAL
FLOAT
ELECTRNC. CIRCUIT
KEY
FIXING
SPRING
SPACER
SCREW
SCREW
THERMOSTAT
ELECTROVALVE
REED
SHAFT
SUPPORT
PIPE
SUPPORT
FIXING
HINGE
HINGE
DISTRIBUTOR
SPRING
SELECTOR SWITCH
SUPPORT
COVER
EMBELLISHER
BASE
SUPPORT
DISTRIBUTOR UNIT
LIFTING UNIT
LIFTING UNIT
WHEEL
SUPPORT
THERMOACTUATOR
SPACER
REGULATOR
USER MANUAL
USER MANUAL
CONNECTOR
CONNECTOR
SUPPORT
ROD
CORD
PROTECTOR
FASTENING
SEAL
SEAL
COVER
SCREW
EXTENSION
MECHANISME
COVER
HANDLE
SEAL
NUT
SHAFT
SEAL
SUPPORT
TAPE

From

Until

Pos.

Reference

Description

255
256
257
262

V72C000B6
LV0860000
V90D000C2
V02A000C9

EXTENSION
PROTECTOR
HANDLE
COUNTERWEIGHT

From

Until

You might also like