You are on page 1of 8

halgan




Halgan
Reflux
Valves
and
Flap
Valves

halgan pty ltd

reflux valve with pumping station


HALGAN REFLUX VALVE WITH PUMPING STATION.
HALGAN REFLUX VALVE WITH PUMPING STATION.
Halgan Reflux Valve with pumping station for wastewater and
Stormwater applications. With telescopic extension for continuous
Halgan
Reflux
Valve with Depth
pumping
wastewater and
Height
and level
adjustment.
486station
640 for
mm.
Stormwater
applications.
With
telescopic
extension
for continuous
Halgan Reflux Valve pumping station used in high risk applications
when
Height
and
level
adjustment.
Depth
486

640
mm.
Wastewater or stormwater backs up or surges. The reflux valve will
Reflux
Valve pumping
usedagainst
in high the
risk backwater.
applications when
CloseHalgan
and pump
activated
when tostation
discharge
Wastewater or stormwater backs up or surges. The reflux valve will
Plug and Play control unit and alarm, with battery backup, has an
Close and pump activated when to discharge against the backwater.
Integrated self-diagnosis system with option for connection to building
Plug and Play control unit and alarm, with battery backup, has an
management system. The control panel displays alarm, operating state
Integrated self-diagnosis system with option for connection to building
and servicing instructions.
management system. The control panel displays alarm, operating state
Pump is Type 3, 1Kw/230 volts. Protection type is IP54. Cable length
and servicing instructions.
5 metres.
Pump is Type 3, 1Kw/230 volts. Protection type is IP54. Cable length
5 metres.

Normal mode Wastewater drains


Wastewater backs up reflux valve
by gravity.
closes.
Normal mode Wastewater drains flapWastewater
backs up reflux valve
by gravity.
flap closes.

When the wastewater on the


inlet
sidethe
backs
up the pump
When
wastewater
on the
inlet
side
backs
up
the
is automatically activatedpump
is pumps
automatically
and
againstactivated
the back
and pumps against the back
water.
water.

Ideal for retro fitting as the drop


Ideal for retro fitting as the drop
between inlet and outlet only 9 mm.
between inlet and outlet only 9 mm.

reflux valve with automatic shut off


Protection from surging sewers, tradewaste pre-treatment devices, stormwater and flood zones.
Ideal for commercial and industrial customers with chemical storage.

IIddeeaall

for the
w

The Halgan valve
Reflux valve
with automatic
shutoff has a dual flap valve. One flap can be manually closed and locked
waatteerrpand
Backwater
Staufix
FKA
Komfort
rofor
Backwater
Staufix
FKA
ccoonnccrrpertoeooff
other flap isvalve
motorised
and will
closeKomfort
automatically when high wastewater is detected by the probe.
et

for
for installation
installation in
in aa concrete
concrete slab/floor
slab/floor
Illustration
Illustration and
and dimensioned
dimensioned drawing
drawing

te

Article
Article description
description

Backwater valve Staufix FKA Komfort


Backwater
Backwater valve
valve
for installation in a concrete slab/floor
Staufix
Staufix FKA
FKA Komfort
Komfort

back-up, motor is rated, protection Type IP 68 (3 m, 24 h).

590
400

min
26
125
125
max 181
125

HH

360
360

DD

min
min26
26
max
max181
181

590
590

400
400

160 L: 656 mm
200 L: 720 mm

H: 370 mm
H: 348 mm

99

voltage/-frequency:
230mm
V AC/50 Hz.

110
642
H:
Supply
110 L:
L:
6425mm
mm
H: 394
394
mm
Cable length:
m (15 m available
on request).

125
125 L:
L: 645
645 mm
mm H:
H: 387
387 mm
mm
160
160 L:
L: 656
656 mm
mm H:
H: 370
370 mm
mm

110 L: 642 mm H: 394 mm

200
L: 720
mm
H:
348
mm

200
348mm
mm
125 L:L:720
645mm
mm H:
H: 387

LL
L

Installation
Installation area
area 750
750 xx 750
750 mm
mm
Installation area 750 x 750 mm

Installation
Installation example
example

Installation example

Backwater
valve
Backwater
valve valve
Backwater
StaufixStaufix
FKA Komfort
Komfort
FKA Komfort
Staufix
FKA
Control
unit
ControlControl
unit unit
set #(Art.
# 83023)
Gasket
set
GasketGasket
set (Art.
(Art.
# 83023)
83023)

diameter
diameter Idea Article #
l Article #
(mm)
(mm) w
for
ate
c rproo

oncre f
te
With recessed
recessed cover
cover
With
for
on-site
tiling
(X)
for on-site tiling (X)
Outer diameter
110
110

Article #
(mm)
125
125

With recessed
cover
160
160
for on-site
tiling (X)
200
200

110

for
with
Article description
for wastewater
wastewater
with or
or without
without sewage
sewage
made
of
polymer,
with
telescopic
made of polymer, with telescopic upper
upper section
section
valve and
forBackwater
continuous heightheightand level
level adjustment
adjustment
for
continuous
FKA Komfort
ForStaufix
installation
in aa concrete
concrete slab/floor
slab/floor
For
installation
in
for
wastewaterdepth
with or without
sewage
for
installation
for installation depth (D)
(D) from
from 486
486 -- 640
640 mm
mm
With
black cover
cover (S)
(S)
125
made
of polymer,
with
telescopic
upper
section
With
black
With
surface
water
tight
cover
plate
class
With
water
tightand
cover
class A
A 15
15
for surface
continuous
heightlevel plate
adjustment

160

110
made of
of polymer.
polymer. Installation
Installation kit
kit with
with choice
choice of
of cover.
cover.
110
made
For installation in a concrete slab/floor
200
125
125
Backwater
valve according
according
to EN
EN486
13564
Type
3 with
with

Backwater
valve
to
13564
for installation
depth (D) from
- 640 Type
mm 3
With
black
cover
two
open
flaps.
Plug-and-Play
control
unit
with
connec 160
160(S)
twoWith
open
flaps.water
Plug-and-Play
control
with connecsurface
tight cover plate
classunit
A 15

tion
option
to
management
alarm,
110
tionmade
option
to building
building
management
system
and
alarm,
of polymer.
Installation
kit with system
choice ofand
cover.
200
200

protection type
type IP
IP 54,
54, with
with integrated
integrated self diagnosis
diagnosis
protection
125
Backwater valve
according
to EN 13564self
Type 3 with
system
SDS,
display
for
operating
status
and
battery
system
SDS,flaps.
display
for operating
status
and connecbattery
two open
Plug-and-Play
control
unit with
back-up,
motor
is rated,
rated,
protection system
Type IP
IPand
68 alarm,
(3 m,
m, 24
24 h).
h). 160
back-up,
motor
is
protection
Type
68
(3
tion option
to building
management
200
Supply
voltage/-frequency:
230
V
AC/50
Hz.
protection
type
IP
54,
with
integrated
self
diagnosis
Supply voltage/-frequency: 230 V AC/50 Hz.
Cable
length:
m
available
on
system
SDS, 5
and battery
Cable
length:
5display
m (15
(15form
moperating
availablestatus
on request).
request).

Illustration and dimensioned drawing

360

Outer
Outer

LGA

LGA
Type-tested
and monitored
Type-tested
with
and monitored
teed
guaran quality
with
testedteed
guaran quality
tested

LGA

Type-tested
and monitored
with
teed
guaran quality
tested

EN
EN 13564
13564 Type
Type 33 FF
EN 13564 Type 3 F

reflux valve with automatic shut off


Backwater valve Staufix FKA Komfort
for installation in an exposed wastewater pipe
Illustration and dimensioned drawing

Outer diameter
(mm)

Article description

Backwater valve
Staufix FKA Komfort
for wastewater with or without sewage
made of polymer
For installation in an exposed wastewater pipe.
With protective cover.
Backwater valve according to EN 13564 Type 3 with
two open flaps. Plug-and-Play control unit with connection option to building management system and alarm,
display for operating status and battery back-up,
protection type IP 54, with integrated self diagnosis
system SDS, display for operating status and battery
back-up, motor is rated protection Type IP 68 (3 m, 24 h).
Supply voltage/-frequency: 230 V AC/50 Hz.
Cable length: 5 m (15 m available on request).

110
125
160
200

L:
L:
L:
L:

642
645
656
720

mm
mm
mm
mm

H:
H:
H:
H:

422
422
422
422

mm
mm
mm
mm

542 x 350

LGA
Type-tested
and monitored
with
teed
guaran quality
tested

Installation example

Backwater valve
Staufix FKA Komfort
Control unit

EN 13564 Type 3 F

110
125
160
200

Article #

reflux valve with twin flap

Ideal
water for
concrproof
ete

Twin flap backwater valve Staufix SWA


for installation in a concrete slab/floor
Illustration and dimensioned drawing

Outer diameter
(mm)

Article description

Twin flap backwater valve Staufix SWA

360

125

With recessed cover


for on-site tiling (X)
110
125
160
200

for wastewater
made of polymer, with telescopic upper section
for continuous height- and level adjustment
For installation in a concrete slab/floor
for installation depth (D) from 486 - 640 mm
With surface water tight cover plate class A 15
made of polymer. Installation kit with choice of cover. With black cover (S)
110
Backwater flap valve according to EN 13564 Type 2
with two self-closing flaps, one of which can be locked
125
by hand as an emergency closure.
160
200
110 L: 642 mm H: 394 mm
125 L: 645 mm H: 387 mm
160 L: 656 mm H: 370 mm
200 L: 720 mm H: 348 mm

590
400

min 26
max 181

Article #

L
LGA

Installation area 750 x 750 mm

EN 13564 Type 2

Type-tested
and monitored
with
teed
guaran quality
tested

Twin flap backwater valve Staufix SWA


for installation in an exposed wastewater pipe
Illustration and dimensioned drawing

Outer diameter
(mm)

Article description

Twin flap backwater valve Staufix SWA


for wastewater
made of polymer
For installation in an exposed wastewater pipe.
With protective cover.
Backwater flap valve according to EN 13564 Type 2
with two self-closing flaps, one of which can be locked
by hand as an emergency closure.

110
125
160
200

L:
L:
L:
L:

642
645
656
720

mm
mm
mm
mm

H:
H:
H:
H:

422
422
422
422

mm
mm
mm
mm

542 x 350

LGA
Type-tested
and monitored
with
teed
guaran quality
tested

EN 13564 Type 2

110
125
160
200

Article #

CODE
RV100
RV125
RV150
RV200
RV300

reflux valve with single flap


Product:
Storm water and surging sewers can be very
expensive but prevention is cheap.
The Halgan Reflux valve ensures that all areas with
openings are always protected from flooding, and
from rodents.

PERFECT FOR
RENOVATION

How it works:
The Halgan Reflux valve is equipped with a hanging,
lockable, flap valve. The flap valve ensures that the
rainwater or sewage flows freely through the valve
while simultaneously preventing any surges into the
building.

Benefits:

Other valves with


large drops are
difficult to install

Designed to stop storm and sewage surges


Protects underground rainwater storage tanks

Offers minimal
drop between
inlet/outlet

from contamination from surging stormwater


(as per HB230-2006)
Stop rodents entering through pipes
All plastic construction
Perfect for renovations - other reflux valves
with large drops are difficult to install, the
Halgan Reflux valve offers minimal drop from
inlet to outlet

SD

D
SL

ASts 5200.006
C of C: 40037
Global-Mark.com.au

L1
D

CODE
110
125
RV100
160
RV125
200
RV150
315
RV200
RV225
RV300

L1
318 D
321 110
350 125
608
735 160

200
250
315

SL
48
53
79
226
120

L1
318
321
350
608
570
735

SD
64
67
106
248
155

SL
48
53
79
226
80
120

SD
64
67
106
248
110
155

flap valve
Backwater flap valves
according to DIN 12056
Illustration and dimensioned drawing

Outer diameter
(mm)

Article description

Multitube single flap


backwater valve

for wastewater
made of polymer
Flap self-closing.
Dimensions in mm:
260 A: 485 B: 455 C:
320 A: 490 B: 470 C:
410 A: 600 B: 610 C:
515 A: 730 B: 700 C:
with connection couplings*.

730
825
900
1230

D:
D:
D:
D:

260
320
410
515

E:
E:
E:
E:

260
320
410
515

110
125
160
200

250
315
405
506
638

800**

1000**

60
35
30
40

Connection couplings allow connection to pipes


with the following outer diameters:
260: 250 - 275 mm
320: 310 - 335 mm
410: 385 - 410 mm
515: 495 - 525 mm

EN 13564 Type 0

Illustration shows 260, 400, 510

Pipe flap valve


for wastewater
made of polymer
Flap self-closing.
Inlet/outlet for connection to PVC pipe
according to DIN 19534.

110
125
160
200

L:
L:
L:
L:

120
136
142
170

mm
mm
mm
mm

EN 13564 Type 0

Pipe flap valve


B1

B2

for wastewater
made of polymer
For use as an end piece.
Flap self-closing.

Illustration shows 250, 315

1137

1100

 800

1035

523

110

1330

1400

 1000

1264

25

Dimensions in mm:
250 H: 400 L: 220 B1: 345 B2: 280
315 H: 450 L: 225 B1: 400 B2: 410
without connection coupling,
connection according to DIN 19534
405 H: 420
506 H: 528
638 H: 659
with connection

L: 295 B1: 417


L: 320 B1: 522
L: 345 B1: 659
coupling*.

Connection couplings allow connection to pipes


with the following outer diameters:
405: 385 - 410 mm
506: 495 - 525 mm
638: 605 - 638 mm
800 1000 -

495

EN 13564 Type 0
** With connection couplings it is possible to connect pipes of different diameters.
Compensating rings are necessary where the difference in outer diameter is > 12 mm.
** For wall installation
Rights reserved for technical changes

Article #

halgan pty ltd


halgan.com.au

Halgan Pty Ltd


Unit 2, 187 South Creek Rd, Cromer NSW 2099
Freecall 1800 626 753
Ph: Sydney 02 9972 1355
Fax: 02 9972 1455
Email: sales@halgan.com.au

Disclaimer
Whilst all care has been taken in compiling this information and it is
provided in good faith, it is not to be relied on as a substitute for
professional advice. Halgan Pty Ltd accepts no responsibility for the
accuracy, completeness or timeliness of the information. For more
information contact your Halgan Pty Ltd

You might also like