You are on page 1of 2

Self potential

Method Type:
Electrical Methods
Assigned Problems:
+
Monitoring
Hazardous Waste
+
Quality / Thickness of concrete
Buildings and Structures
0
Aquifer pollution
Groundwater
0
Cavity detection
Civil Engineering
0
Host sediments, hydogeological settings
Hazardous Waste
0
Landslides
Natural Hazards
0
Porosity / Permeability
Groundwater
'+' = Technique applicable; '0' = Application possible/limited use.

Principle:
The spontaneous or self potential (SP) method is a passive electrical technique that involves
measurement of naturally occurring ground potentials. The two main sources of SP signals
important in environmental and engineering studies are streaming potentials, due to movement of
water through porous subsurface materials, and diffusion potentials resulting from differing
concentrations of electrolytes within the groundwater.
Keywords:
Spontaneous or self potential (SP); natural potential; diffusion potentials; electrokinetic effects;
maps (2-D) of SP distribution; SP tomograms
Prerequisites:
- Natural Potential caused by, e.g., groundwater flow; variation in electrolyte concentration in the
ground, must exist.
- Buried wires, metal pipes, metal fences may influence measurements.
- Urban areas may cause high noise levels (e.g. stray currents).
- High-voltage power lines, railways and antennas may influence measurements.
- Measurements during rain should be avoided.
- Changing waether conditions may influence measurements.
- Ground coupling/surface conditions around electrodes influence measurements.
- In some areas electrode coupling may be poor (e.g., asphalt, gravel, dry sand).
- Topography effects need to be considered.
- SP measurements are very sensitive to time variant noise (e.g., telluric currents; bioelectric
potentials; poor electrode coupling).
- Profiles > 1 km may need special corrections for laterally varying telluric currents.
Resolution:
Since data interpretation is mostly qualitative, measures of resolutions are difficult to specify. At
best horizontal resolution is of the order of electrode spacing in gradient array configuration.
Expected Results:
- Measured parameter: electrical potential differences in mV. Values for groundwater studies are
within several tens of mV. Over graphite or some sulfides deposits, anomaly can reach more
than some hundreds of mV.
- Data analysis: voltages are plotted in form of apparent resistivities as profiles or contour maps.
Results are typically displayed in profiles or contour maps. Forward modelling or SP
tomography can provide a semi-quantitative interpretation.
- Interpretation: the origin of natural potentials is not entirely understood yet; some role of thumb
where potentials occur are: Natural potential increase with increasing hydraulic gradient and
groundwater flow through formations with different hydraulic conductivity are normally
associated with natural potentials.

page 1

Combination with other Methods:


- Required additional information: knowledge of the gross resistivity subsurface structure.
- Related add-on information: electrical data; induced polarization data; magnetics data; thermal
data; seismic data
- Interpretation: NA
Operation Expense:
- Crew size: 1 key person, 1-2 assistants
- Acquisition speed: 200 - 500 measurements per day, depending on the electrode spacing and
terrain.
- Processing:requires 1 - 2 days per acquisition day.
- Equipment rental costs: low
Parameters to specify:
- Array type (gradient or total field array): The gradient array is faster in use but more susceptible
to errors then the total field array. Total length of array can be up to several kilometres..
- Electrode spacing: Usually between 1 and several tensof m.
QC Documents:
- Measurements of reproducibility (measurements of reciprocal or redundant configurations).
- Optional: Map of buried cables, roads.
Products:
- Maps (2-D) of self-potential distribution
- Interpretation
- Optional: self-potential tomograms (2-D self-potential distribution with depth).