Professional Documents
Culture Documents
Method Type:
Electrical Methods
Assigned Problems:
+
Monitoring
Hazardous Waste
+
Quality / Thickness of concrete
Buildings and Structures
0
Aquifer pollution
Groundwater
0
Cavity detection
Civil Engineering
0
Host sediments, hydogeological settings
Hazardous Waste
0
Landslides
Natural Hazards
0
Porosity / Permeability
Groundwater
'+' = Technique applicable; '0' = Application possible/limited use.
Principle:
The spontaneous or self potential (SP) method is a passive electrical technique that involves
measurement of naturally occurring ground potentials. The two main sources of SP signals
important in environmental and engineering studies are streaming potentials, due to movement of
water through porous subsurface materials, and diffusion potentials resulting from differing
concentrations of electrolytes within the groundwater.
Keywords:
Spontaneous or self potential (SP); natural potential; diffusion potentials; electrokinetic effects;
maps (2-D) of SP distribution; SP tomograms
Prerequisites:
- Natural Potential caused by, e.g., groundwater flow; variation in electrolyte concentration in the
ground, must exist.
- Buried wires, metal pipes, metal fences may influence measurements.
- Urban areas may cause high noise levels (e.g. stray currents).
- High-voltage power lines, railways and antennas may influence measurements.
- Measurements during rain should be avoided.
- Changing waether conditions may influence measurements.
- Ground coupling/surface conditions around electrodes influence measurements.
- In some areas electrode coupling may be poor (e.g., asphalt, gravel, dry sand).
- Topography effects need to be considered.
- SP measurements are very sensitive to time variant noise (e.g., telluric currents; bioelectric
potentials; poor electrode coupling).
- Profiles > 1 km may need special corrections for laterally varying telluric currents.
Resolution:
Since data interpretation is mostly qualitative, measures of resolutions are difficult to specify. At
best horizontal resolution is of the order of electrode spacing in gradient array configuration.
Expected Results:
- Measured parameter: electrical potential differences in mV. Values for groundwater studies are
within several tens of mV. Over graphite or some sulfides deposits, anomaly can reach more
than some hundreds of mV.
- Data analysis: voltages are plotted in form of apparent resistivities as profiles or contour maps.
Results are typically displayed in profiles or contour maps. Forward modelling or SP
tomography can provide a semi-quantitative interpretation.
- Interpretation: the origin of natural potentials is not entirely understood yet; some role of thumb
where potentials occur are: Natural potential increase with increasing hydraulic gradient and
groundwater flow through formations with different hydraulic conductivity are normally
associated with natural potentials.