Professional Documents
Culture Documents
Pgina 1 de 6
VSA_89600B_MIMO_Source
Model Parameters
Name
Description
Default
Units Type
VSATitle
Simulation
source
RepeatData
VSA hardware
Reacquire
measurement
control: Repeat,
Reacquire,
Single pass
Enumeration NO
Pause
Enumeration NO
SetupFile
Name of setup
file to recall into
VSA
SetupUse
Always
Enumeration NO
SampleRateOption
From Traces
Enumeration NO
SampleRate
Sample rate
Sample_Rate Hz
sepcified by user
Float
NumberOfAntennas
Number of
receiver
attennas: 2
Antennas, 3
Antennas, 4
Antennas
2 Antennas
Enumeration NO
Antenna1_Trace
Enumeration NO
NO
Text
Filename
Runtime Range
Tunable
NO
NO
NO
mk:@MSITStore:C:\Archivos%20de%20programa\SystemVue2011.03\Help\SYSTE...
13/9/2014
VSA_89600B_MIMO_Source
Pgina 2 de 6
Enumeration NO
Antenna3_Trace
Enumeration NO
Antenna4_Trace
Enumeration NO
RecordingFile
Name of
recording file to
recall into VSA
to be played
back
AutoCapture
Capture VSA
input data at
start-up: NO,
YES
Filename
NO
NO
Enumeration NO
Enumeration NO
DefaultHardware
Enumeration NO
SetFrequencySpan
Enables the
NO
FrequencySpan
parameter.: NO,
YES
Enumeration NO
FrequencySpan
If non-zero, set
the frequency
span.
SetCenterFrequency
Enables the
NO
CenterFrequency
parameter.: NO,
YES
CenterFrequency
Center
frequency
SetRange
Enables the
NO
Range
parameter.: NO,
YES
Hz
Float
NO
[0:)
Enumeration NO
Hz
Float
NO
(:)
Enumeration NO
mk:@MSITStore:C:\Archivos%20de%20programa\SystemVue2011.03\Help\SYSTE...
13/9/2014
VSA_89600B_MIMO_Source
Pgina 3 de 6
Range
If non-zero and
RecordingFile
not set, set the
range.
Float
NO
[0:)
RecordingLength
If non-zero and
RecordingFile
not set, this
parameter set
the recording
length.
Float
NO
[0:)
GapOut
Enable
outputting
measurement
Gap flag.: NO,
YES
NO
Enumeration NO
This part is to be used with VSA 89600B software. If you only have VSA 89600
software installed, please use VSA_89600_MIMO_Sink part instead.
Important Note: In order to speed up the VSA start-up, all VSA's created by
SystemVue will remain running in the background even when their windows are closed
by the user. They will be closed together on exiting SystemVue. You can manually
close them all via menu *Action -> Exit Vector Signal Analyzer (89600 VSA) * or close
them selectively through the window's task manager.
VSA 89600B MIMO Source is for MIMO applications only. It is designed to retrieve
the time domain data of multiple RF sources captured by VSA SW and stream them
into simulation for measurements such as Bit Error Rate measurement.
To retrieve other measurement data (e.g. spectrum) from VSA SW, please use
VSA_89600B_Source.
mk:@MSITStore:C:\Archivos%20de%20programa\SystemVue2011.03\Help\SYSTE...
13/9/2014
VSA_89600B_MIMO_Source
Pgina 4 de 6
6. Recorded Data File (Optional): If data are read in from some recorded data file (e.g.
SDF data file) in stead of be acquired through "live" measurements via VSA SW, use this
file browser to locate the data file.
7. Output Measurements Gap Flag: When simulation requires more data than that can
be captured by one VSA measurement, multiple measurements need to be made and the
aggregated ("stitched") data are not continuous, i.e. there will be time gaps in the data
stream. This check box allows an additional "Gap" flag out put to notify whether a gap
happened in between 2 captured data. If the value is 0, no gap happened. If it is 1, gap
occurred. To overcome gap, use the Automatic Capture check box described later.
8. Antenna1/2/3/4: This is to specify data from which trace from VSA SW are used to
feed which output pin of the VSA 89600B MIMO part.
3. Override VSA Setup: The VSA setups specified here will be applied to adjust VSA setup
mk:@MSITStore:C:\Archivos%20de%20programa\SystemVue2011.03\Help\SYSTE...
13/9/2014
VSA_89600B_MIMO_Source
Pgina 5 de 6
If desired, click the Advanced Options ... button on the bottom left corner of VSA
MIMO Main Properties to view the parameter list. The mapping between the
parameters in the parameter list and the setup controls shown in the 2 Graphic User
Interfaces described above should be straightforward.
mk:@MSITStore:C:\Archivos%20de%20programa\SystemVue2011.03\Help\SYSTE...
13/9/2014
VSA_89600B_MIMO_Source
Pgina 6 de 6
Important Links
1. Download latest VSA SW with 14 day trial license from Agilent Technologies
2. If you did NOT install the Agilent IO library during the VSA SW installation, you can also
download Agilent IO Library yourself.
3. Also see related parts:
VSA_89600B_Sink
VSA_89600B_Source
VSA_89600B_MIMO_Sink
mk:@MSITStore:C:\Archivos%20de%20programa\SystemVue2011.03\Help\SYSTE...
13/9/2014