You are on page 1of 9

Type of Monitoring

Test Results issued to: M/s. AICONS Engineering Pvt. Ltd


A-06, Janki Residency, Near Vishal Mega Mart, Kolar Road, Bhopal M.P

Ambient Air Quality Analysis


Ground Water Analysis
Soil Quality Analysis
Ambient Noise

SAMPLING & ANALYSIS DATA

Sampling
Sr.
No.

Road Name

1.

Type of Sample

Harphari Khaira Road


(Harphari Village
KM.2+050)

Ambient Air Quality

Date of
Sample
Collection
07.09.2014

Ambient
temperature
30o C

Weather
Condition
Clear

TEST RESULT

1.

Particulate Matter (PM10)

IS:5182 Part-XXIII

76

g /m3

Limits as per
Environment
(Protection) Act.
100.0

2.

Particulate Matter (PM2.5)

CPCB Volume 1 / Grav

23

g /m3

60.0

80.0

S.No.

Parameter

Test Method

Results

Units

3.

Sulphur Dioxide

IS:5182 Part-II

6.4

g /m

4.

Nitrogen Dioxide

IS:5182 Part-VI

16.3

g /m3

80

5.

Carbon Monoxide

IS:5182 Part-X

0.370

mg/m3

4.0

Notes:
1. The results are on the basis of collection of sample, as received from Aicons Engineering Pvt. Ltd.
2. Third Party testing has been conducted on request of Customer.
3. This test report shall not be used for any publicity/legal purpose

CHECKED BY

AUTHORIZED SIGNATORY

Add :- B-3, #03, Uni Homes, Kolar Road Bhopal

Type of Monitoring

Test Results issued to: M/s. AICONS Engineering Pvt. Ltd


A-06, Janki Residency, Near Vishal Mega Mart, Kolar Road, Bhopal M.P

Ambient Air Quality Analysis


Ground Water Analysis
Soil Quality Analysis
Ambient Noise

SAMPLING & ANALYSIS DATA

Sampling
Sr.
No.

Road Name

1.

Type of Sample

Harphari Khaira Road


(Khaira Village
KM.25+330)

Ambient Air Quality

Date of
Sample
Collection
07.09.2014

Ambient
temperature
30o C

Weather
Condition
Clear

TEST RESULT

1.

Particulate Matter (PM10)

IS:5182 Part-XXIII

73

g /m3

Limits as per
Environment
(Protection) Act.
100.0

2.

Particulate Matter (PM2.5)

CPCB Volume 1 / Grav

22

g /m3

60.0

3.

Sulphur Dioxide

IS:5182 Part-II

6.8

g /m3

80.0

4.

Nitrogen Dioxide

IS:5182 Part-VI

17.3

S.No.

5.

Parameter

Carbon Monoxide

Test Method

IS:5182 Part-X

Results

Units

0.363

g /m3

80

4.0

mg/m

Notes:
1. The results are on the basis of collection of sample, as received from Aicons Engineering Pvt. Ltd..
2. Third Party testing has been conducted on request of Customer.
3. This test report shall not be used for any publicity/legal purpose.

CHECKED BY

AUTHORIZED SIGNATORY

Add :- B-3, #03, Uni Homes, Kolar Road Bhopal

Type of Monitoring

Test Results issued to: M/s. AICONS Engineering Pvt. Ltd


A-06, Janki Residency, Near Vishal Mega Mart, Kolar Road, Bhopal M.P

Ambient Air Quality Analysis


Ground Water Analysis
Soil Quality Analysis
Ambient Noise

SAMPLING & ANALYSIS DATA

Sampling
Sr.
No.
1.

Road Name

Type of Sample

Harphari Khaira Road


(Harphari Village
KM.2+050)

Ground Water Quality

Date of
Sample
Collection
07.09.2014

Source of
Sample

Weather
Condition

HandPump

Clear

ORGANOLEPTIC & PHYSICAL PARAMETERS


S.NO. Parameter

1
2
3
4

5
6

7
8

9
10

Unit

Test Method

pH
Temperature

IS-3025(P-11)

Dissolved
Oxygen
Conductivity

mg/l

Requirement
(Acceptable
Limit)

Permissible
Limit in
absence of
alternate source

Result

6.5-8.5
-

7.09
30

3025(P-38)

3.6

mhos/c
m
mg/l

IS-3025(P-14)

959.12

IS-3025(P-17)

<1.0

mg/l

IS-3025(P-16)

500

2000

622.5

mg/l

IS: 3025 (P- 23)

200

600

312

Total
mg/l
Hardness as
CaCO3
Ca Hardness mg/l
as CaCO3
Mg Hardness mg/l
as CaCO3

IS: 3025 (P- 23)

300

600

361.06

IS: 3025 (P- 40)

75

200

260

IS: 3025 (P-46)

30

100

71

@250C
Total
Suspended
Solid

Total
Dissolved
Solid
Alkalinity

Add :- B-3, #03, Uni Homes, Kolar Road Bhopal

11
12
13
14
15
16
17
18

Chlorides as
Cl
Phosphate as
PO4
Nitrates
as
NO3
Sulphates as
SO4
Sodium as Na
Potassium (as
K)
COD
0

BOD (at 27 C
3-Days)

mg/l

IS: 3025 (P- 32)

mg/l

IS-3025(P-31)

mg/l

250

1000

51

<0.1

IS: 3025 (P- 34)

45

100

3.0

mg/l

IS: 3025 (P- 24)

200

400

47.0

mg/l
mg/l

IS-3025(P-45)
IS-3025(P-45)

41
4

mg/l
mg/l

APHA-5220B

BDL
BDL

IS-3025(P-44)

Notes:
1. The results are on the basis of collection of sample, as received from Aicons Engineering Pvt. Ltd..
2. Third Party testing has been conducted on request of Customer.
3. This test report shall not be used for any publicity/legal purpose.

CHECKED BY

AUTHORIZED SIGNATORY

Add :- B-3, #03, Uni Homes, Kolar Road Bhopal

Type of Monitoring

Test Results issued to: M/s. AICONS Engineering Pvt. Ltd


A-06, Janki Residency, Near Vishal Mega Mart, Kolar Road, Bhopal M.P

Ambient Air Quality Analysis


Ground Water Analysis
Soil Quality Analysis
Ambient Noise

SAMPLING & ANALYSIS DATA

Sampling
Sr.
No.
1.

Road Name

Type of Sample

Harphari Khaira Road


(Khaira Village
KM.25+ 330)

Ground Water Quality

Date of
Sample
Collection
07.09.2014

Source of
Sample

Weather
Condition

HandPump

Clear

ORGANOLEPTIC & PHYSICAL PARAMETERS


S.NO Parameter
.

Unit

Test Method

Requirement
(Acceptable
Limit)

pH
Temperature

IS-3025(P-11)

6.5-8.5
-

7.12
31

Dissolved
Oxygen
Conductivity

mg/l

3025(P-38)

3.4

mhos/c
m
mg/l

IS-3025(P-14)

959.22

IS-3025(P-17)

<1.0

Total
Dissolved
Solid
Alkalinity

mg/l

IS-3025(P-16)

500

2000

624

mg/l

IS: 3025 (P- 23)

200

600

312

Total
Hardness
CaCO3

mg/l

IS: 3025 (P- 23)

300

600

362

Ca Hardness mg/l
as CaCO3
Mg Hardness mg/l
as CaCO3

IS: 3025 (P- 40)

75

200

262

IS: 3025 (P-46)

30

100

68

2
3
4

5
6

7
8

9
10

@250C
Total
Suspended
Solid

Permissible
Limit in
absence of
alternate
source

Result

as

Add :- B-3, #03, Uni Homes, Kolar Road Bhopal

11
12
13
14
15
16
17
18

Chlorides as
Cl
Phosphate as
PO4
Nitrates
as
NO3
Sulphates as
SO4
Sodium as Na
Potassium (as
K)
COD
0

BOD (at 27 C
3-Days)

mg/l

IS: 3025 (P- 32)

mg/l

IS-3025(P-31)

mg/l

250

1000

49

<0.1

IS: 3025 (P- 34)

45

100

3.6

mg/l

IS: 3025 (P- 24)

200

400

47.45

mg/l
mg/l

IS-3025(P-45)
IS-3025(P-45)

43
6

mg/l
mg/l

APHA-5220B

BDL
BDL

IS-3025(P-44)

Notes:
1. The results are on the basis of collection of sample, as received from Aicons Engineering Pvt. Ltd..
2. Third Party testing has been conducted on request of Customer.
3. This test report shall not be used for any publicity/legal purpose

CHECKED BY

AUTHORIZED SIGNATORY

Add :- B-3, #03, Uni Homes, Kolar Road Bhopal

Type of Monitoring

Test Results issued to: M/s. AICONS Engineering Pvt. Ltd


A-06, Janki Residency, Near Vishal Mega Mart, Kolar Road, Bhopal M.P

Ambient Air Quality Analysis


Ground Water Analysis
Soil Quality Analysis
Ambient Noise

SAMPLING & ANALYSIS DATA

Sampling
Sr.
No.
1.

Road Name

Type of Sample

Harphari Khaira Road


(Harphari Village
KM.2+050)

Soil Quality Analysis

Date of
Sample
Collection
07.09.2014

Weather
Condition

Ambient
temperature
30o C

RESULT
7.33

Clear

S.No. PARAMETERTS
1.
pH(1:5 suspension)

TEST METHOD
IS:2720(Part-26)

2.

IS:2720(Part-21)

106.1

mhos/cm

3.

Electrical Conductivity at
25OC (1:5suspension.)
Bulk Density

STP/SOIL

1.341

gm /cm3

4.

Moisture

STP/SOIL

24

5.

Texture

STP/SOIL

6.

Sand

STP/SOIL

Sandy Clay
Loam
53

% by mass

7.

Clay

STP/SOIL

22

% by mass

8.

Silt

STP/SOIL

11

% by mass

9.

Cation Exchange Capacity

STP/SOIL

2.10

mg/ kg

10.

Nitrogen

STP/SOIL

60.2

mg/1000g

11.

Potassium (as K)

STP/SOIL

0.3

mg/kg

12.

Phosphorus

STP/SOIL

74

mg/1000g

Add :- B-3, #03, Uni Homes, Kolar Road Bhopal

UNIT
-

13.

Calcium

STP/SOIL

2.1

mg/1000g

14.

Magnesium

STP/SOIL

1.30

mg/1000g

15.

Organic Carbon

STP/SOIL

0.21

%by mass

Notes:
1. The results are on the basis of collection of sample, as received from Aicons Engineering Pvt. Ltd..
2. Third Party testing has been conducted on request of Customer.
3. This test report shall not be used for any publicity/legal purpose.

CHECKED BY

AUTHORIZED SIGNATORY

Add :- B-3, #03, Uni Homes, Kolar Road Bhopal

Type of Monitoring

Test Results issued to: M/s. AICONS Engineering Pvt. Ltd


A-06, Janki Residency, Near Vishal Mega Mart, Kolar Road, Bhopal M.P

Ambient Air Quality Analysis


Ground Water Analysis
Soil Quality Analysis
Ambient Noise

SAMPLING & ANALYSIS DATA

Sampling
Sr.
No.

Road Name

1.

Type of Sample

Harphari Khaira Road


(Harphari Village
KM.2+050)

Ambient Noise

Date of
Sample
Collection
07.09.2014

Ambient
temperature

Weather
Condition

30o C

Clear

TEST RESULT
S. No

*
Results

Test Parameters

1.

EQUIVALENT
NOISE LEVEL
(6.0 AM TO 10.0 PM)

2.

EQUIVALENT
NOISE LEVEL
(10.0 PM TO 6.0
AM)

47

Units

dB(A)

Requirement (as per CPCB Guidelines Limits in


dB (A) Leq
Category of Area/
Day Time
Night Time
Zone
Industrial Area
75
70
Commercial Area

38.5

dB(A)

*Residential
Area
Silence Zone

65

55

55

45

50

40

Notes:
1. The results are on the basis of collection of sample, as received from Aicons Engineering Pvt. Ltd..
2. Third Party testing has been conducted on request of Customer.
3. This test report shall not be used for any publicity/legal purpose.

CHECKED BY

AUTHORIZED SIGNATORY
Add :- B-3, #03, Uni Homes, Kolar Road Bhopal

You might also like