You are on page 1of 16

4

Control Equipments
Control Unit System
BZA8050 Series Explosion-proof Control Unit
System
 Explosion protection to
-CENELEC
-IEC
 Can be used
in Zone 1 and Zone 2
in Zone 21 and Zone 22
 GRP (glass fibre-reinforced polyester resin)
 3 enclosure types
 Individual unit can be combined into larger units.

 Catalogue number logic


BZA 8050 - A  D 

Indicator number
Indicator (optional)
Control button number
Control button (optional)
Design No.
Explosion-proof control unit system

 Note
1. Please refer to the Selection Table on P4/21-22.
2. Please select internal components as below:
BA8050 control button selection table on P4/36 (Nominal contact is 1NO+1NC)
BD8050 indicator selection table on P4/40
3. Example: BZA8050-A2
Components: two control buttons
Tech Details: One start control button (40092B + 40090-1+40091-1, green, 1NO+1NC);
One stop control button (40092A+ 40090-1+40091-1, red, 1NO+1NC)
4. Special requirements on request.

Zones 1&2; 21&22


4/20

General Catalogue 01.01.2010

http:// www.waromgroup.com

Control Unit System


BZA8050 Series Explosion-proof Control Unit System

Selection table
Outline
Spring-return button

Ordering code
Red

Weight (kg)

40063A
0.65

Green
Mushroom stay-put emergency button

40063B

Red
40064

0.65

40065A

0.65

40065B

0.65

40065C

0.65

40066

0.85

40067

0.85

40068

0.85

Rotary button

Spring-return button

Red

Green

Indicator and mushroom


stay-put emergency button

Red

Red

Indicator and double button

Red

Red

Green

General Catalogue 01.01.2010

http:// www.waromgroup.com

4/21

Control Unit System


BZA8050 Series Explosion-proof Control Unit System

Selection table
Outline
Spring-return button

Ordering code

Weight (kg)

40069

1.10

40070

1.10

40071

1.10

40072

1.10

40073

1.10

Red

Green

Yellow

Spring-return button and


indicator

Red

Red

Green

Spring-return button and mushroom

Red

stay-put emergency button


Green

Red

Spring-return button and

Red

rotary button
Green

Red

Double button, mushroom Red


stay-put emergency
button and indicator

Red
Green

Red

4/22

General Catalogue 01.01.2010

http:// www.waromgroup.com

Control Unit System


BZA8050 Series Explosion-proof Control Unit System

Technical data
Explosion-proof control unit system

BZA8050

Explosion protection
Gas explosion protection

II 2G Ex de IIC T6

Dust explosion protection

Ex tD A21 IP65 T85

Certificates
For gas explosion protection

LCIE 09 ATEX 3097

For dust explosion protection

PCEC(China)

Conformity to standards

EN 60079-0:2006; EN 60079-1:2004; EN 60079-7:2007;


IEC 60079-0:2004; IEC 60079-1:2003; IEC 60079-7:2006;
IEC 61241-0:2004; IEC 61241-1:2004

Enclosure material
Enclosure color
Exposed fastener
Rated voltage
Rated current
Degree of protection
Ambient temperature
Cable entries
Available cable outer diameter

GRP (glass fibre-reinforced polyester resin)


Black
Stainless steel
max. 415V AC
10A
IP65
-20+55
1-M25 x 1.5 Cable gland (DQM- I, plastic)
916

Dimension drawings (all dimensions in mm) - subject to alteration

H
H

Enclosure I

Enclosure II

Enclosure III
Note: H adjusts to the components size.

General Catalogue 01.01.2010

http:// www.waromgroup.com

4/23

Control Equipments
Control Stations (GRP)
BZC8050 Series Explosion-proof
Control Stations
 Explosion protection to
-CENELEC
-IEC
 Can be used
in Zone 1 and Zone 2
in Zone 21 and Zone 22
 GRP (glass fibre-reinforced polyester resin)
 4 enclosure types
 Components:
-BA8050 control buttons
-BD8050 indicators
-BK8050 control switches
-BB8050 ammeters
-BB8050 voltmeters

 Catalogue number logic


BZC 8050 - A  D  K  B 

Mounting (G: surface type / L: pole type)


Ammeter/Voltmeter number
Ammeter/Voltmeter (optional)
Control switch number
Control switch (optional)
Indicator number
Indicator (optional)
Control button number
Control button (optional)
Design No.
Explosion-proof control stations

 Note
1. Please refer to the Selection Table on P4/25.
2. Please select components as below:
BA8050 control button selection table on P4/36 (nominal contact is 1NO+1NC)
BD8050 indicator selection table on P4/40;
BK8050 control switch selection table on P4/43
BB8050 ammeter/voltmeter selection table on P4/49
3. Example: BZC8050-A2D2G
Components: Two control buttons, two indicators; surface type
Tech Details: One start control button (40092B + 40090-1+40091-1, green, 1NO+1NC);
One stop control button (40092A+ 40090-1+40091-1, red, 1NO+1NC);
One indicator (40116+40100-2, green, AC 230V);
One indicator (40115+40099-2, red, AC 230V);
4. Special requirements on request.

Zones 1&2; 21&22


4/24

General Catalogue 01.01.2010

http:// www.waromgroup.com

Control Stations (GRP)


BZC8050 Series Explosion-proof Control Stations

Selection table
Enclosure type

Components arrangement

II

IIIx

IV

General Catalogue 01.01.2010

and direction

weight (kg)

code

http:// www.waromgroup.com

2-M25 x 1.5
40074......
Bottom entry

1.30

1-M32 x 1.5
or
2-M25 x 1.5 40075......
Bottom entry

2.10

1-M32 x 1.5
or
40076......
3-M25 x 1.5
Bottom entry

3.25

1-M40 x 1.5
or
2-M32 x 1.5
40077......
or
4-M25 x 1.5
Bottom entry

3.25

III

Enclosure

Cable entries Ordering

1-M40 x 1.5
or
2-M32 x 1.5
40078......
or
6-M25 x 1.5
Bottom entry

4.15

4/25

Control Stations (GRP)


BZC8050 Series Explosion-proof Control Stations

Technical data
Explosion-proof control stations

BZC8050 (GRP)

Explosion protection
Gas explosion protection

II 2G Ex de IIC T6

Dust explosion protection

Ex tD A21 IP65 T85

Certificates
For gas explosion protection

LCIE 09 ATEX 3099

For dust explosion protection

PCEC(China)

Conformity to standards

EN 60079-0:2006; EN 60079-1:2004; EN 60079-7:2007;


IEC 60079-0:2004; IEC 60079-1:2003; IEC 60079-7:2006;
IEC 61241-0:2004; IEC 61241-1:2004

Enclosure material
Enclosure color
Exposed fastener
Rated voltage
Rated current
Degree of protection
Ambient temperature
Components

GRP (glass fibre-reinforced polyester resin)


Black
Stainless steel
max. 415V AC
10A
IP65
-20+55
1. BA8050 control button technical data on P4/36;
2. BD8050 indicator technical data on P4/40;
3. BK8050 control switch technical data on P4/43;
4. BB8050 ammeter technical data on P4/49;
5. BB8050 voltmeter technical data on P4/49.

Cable entries
Cable gland(optional)
Mounting

M  x 1.5 plug, please see the selection table on P4/25


DQM-I (Ex e) is recommended. Please see P7/16.
1. Please specify the number, size and direction of entries (applicable for
surface type only).
2. Standard mounting is surface type .
3. For pole type, only G1entry is applicable.

Dimension drawings (all dimensions in mm) - subject to alteration

Enclosure I

Enclosure II

Note: H adjusts to the components size.

4/26

General Catalogue 01.01.2010

http:// www.waromgroup.com

Control Stations (GRP)


BZC8050 Series Explosion-proof Control Stations

Dimension drawings (all dimensions in mm) - subject to alteration

Enclosure III

Enclosure IV

Pole type (for enclosure I, II, III only)

Note: H adjusts to the components size.

General Catalogue 01.01.2010

http:// www.waromgroup.com

4/27

Control Equipments
Control Stations (Ex d II B)
BZC Series Explosion-proof Control Stations
 Explosion protection to
-CENELEC
-IEC
 Can be used
in Zone 1 and Zone 2
 Copper-free aluminium enclosure; powder coated external
surface.
 6 enclosure types.

=Catalogue number logic


BZC - A  D  K  B 

Ammeter/Voltmeter number
Ammeter/Voltmeter (optional)
Switch number
Switch (optional)
Indicator number
Indicator (optional)
Pushbutton number
Pushbutton (optional)
Explosion-proof control stations

 Note
1. Please refer to the Selection Table on P4/5.
2. Please select internal components as below:
HA pushbutton selection table on P4/12 (Nominal contact is 1NO+1NC)
HD indicator selection table on P4/14
HK switch selection table on P4/16
BB8050 ammeter/voltmeter selection table on P4/49
3. Example: BZC-A2B1K1
Components: Two pushbuttons, one ammeter, one switch
Tech Details: One start pushbutton (40036B-1 + 40033-1, green, 1NO+1NC);
One stop pushbutton (40036A-1 + 40033-1, red, 1NO+1NC);
One ammeter (40139, 100/5A);
One switch (Function A, stop-run-start)
4. Special requirements on request.

Zones 1&2
4/4

General Catalogue 01.01.2010

http:// www.waromgroup.com

Control Stations (Ex d IIB)


BZC Series Explosion-proof Control Stations

Control station BZC (Ex d IIB) selection table


Enclosure type

Components arrangement

II

weight (kg)

2-M25 x 1.5
Bottom entry

40017......

6.70

1-M32 x 1.5
or
2-M25 x 1.5
Bottom entry

40018......

9.80

1-M32 x 1.5
or
3-M25 x 1.5
Bottom entry

40019......

10.80

40020......

14.70

1-M40 x 1.5
or
2-M32 x 1.5
or
4-M25 x 1.5
Bottom entry

IV
d

Enclosure

code

III

Ordering

and direction

Cable entries

1-M40 x 1.5
or
4-M32 x 1.5
or
6-M25 x 1.5
Bottom entry

40021......

21.20

40022......

34.00

c
1-M40 x 1.5
or
4-M32 x 1.5
or
6-M25 x 1.5
Bottom entry

VI

General Catalogue 01.01.2010

http:// www.waromgroup.com

4/5

Control Stations (Ex d IIB)


BZC Series Explosion-proof Control Stations

Technical data
Explosion-proof control stations

BZC (Ex d IIB)

Explosion protection
Gas explosion protection

II 2G Ex d IIB T6

Certificates
For gas explosion protection

Conformity to standards

LCIE 10 ATEX____PCEC(China);
EN60079-0:2006EN60079-1:2004
IEC 60079-0:2004; IEC 60079-1:2003;

Enclosure material
Enclosure color
Exposed fastener
Rated voltage
Rated current
Degree of protection
Ambient temperature
Components

Copper-free aluminium; powder coated external surface


Grey
Stainless steel
max. 415V AC
10A
IP65
-20+55
1. HA pushbutton technical data on P4/12;
2. HD indicator technical data on P4/14;
3. HK switch technical data on P4/16;
4. BB8050 ammeter technical data on P4/49;
5. BB8050 voltmeter technical data on P4/49.

Cable entries
Cable gland(optional)
Terminal

Standard M  x 1.5 plug. Please see the selection table on P4/5


DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/2025.
Weidmuller SAK EN series

Dimension drawings (all dimensions in mm) - subject to alteration

Enclosure I

Enclosure II

4/6

General Catalogue 01.01.2010

http:// www.waromgroup.com

Control Stations (Ex d IIB)


BZC Series Explosion-proof Control Stations

Dimension drawings (all dimensions in mm) - subject to alteration

Enclosure III

Enclosure IV

Enclosure V

Enclosure VI

General Catalogue 01.01.2010

http:// www.waromgroup.com

4/7

Control Equipments
Control Stations (Ex de IIB)
BZC Series Explosion-proof Control Stations
 Explosion protection to
-CENELEC
-IEC
 Can be used
in Zone 1 and Zone 2
 Copper-free aluminium enclosure; powder coated external
surface.
 7 enclosure types.

 Catalogue number logic


BZC - A  D  K  B  

Mounting (G: surface type/L: pole type)


Ammeter/Voltmeter number
Ammeter/Voltmeter (optional)
Switch number
Switch (optional)
Indicator number
Indicator (optional)
Pushbutton number
Pushbutton (optional)
Explosion-proof control stations

 Note
1. Please refer to the Selection Table on P4/5.
2. Please select internal components as below:
HA pushbutton selection table on P4/12 (Nominal contact is 1NO+1NC);
HD indicator selection table on P4/14
HK switch selection table on P4/16
BB8050 ammeter/voltmeter selection table on P4/49
3. Example: BZC-A2B1K1L
Components: Two pushbuttons, one ammeter, one switch; pole type
Tech Details: One start pushbutton (40036B-1 + 40033-1, green, 1NO+1NC);
One stop pushbutton (40036A-1 + 40033-1, red, 1NO+1NC);
One ammeter (40139, 100/5A);
One switch (Function A, stop-run-start);
4. Special requirements on request.

Zones 1&2
4/8

General Catalogue 01.01.2010

http:// www.waromgroup.com

Control Stations (Ex de IIB)


BZC Series Explosion-proof Control Stations

Control station BZC (Ex de IIB) selection table


Enclosure type

Components arrangement

VI

40025......

4.15

1-M32 x 1.5
Bottom entry

40026......

5.30

1-M32 x 1.5
Bottom entry

40027......

6.65

1-M32 x 1.5
Bottom entry

40028......

6.80

1-M32 x 1.5
or
2-M25 x 1.5
Bottom entry

40029......

13.0

1-M40 x 1.5
or
1-M32 x 1.5
or
4-M25 x 1.5
Bottom entry

40030......

15.25

1-M40 x 1.5
or
4-M32 x 1.5
or
6-M25 x 1.5
Bottom entry

40031......

40.65

VII

General Catalogue 01.01.2010

1-M32 x 1.5
Bottom entry

IV

weight (kg)

III

Enclosure

code

II

Ordering

and direction

Cable entries

http:// www.waromgroup.com

4/9

Control Stations(Ex de IIB)


BZC Series Explosion-proof Control Stations

Technical data
Explosion-proof control stations

BZC (Ex de IIB)

Explosion protection
Gas explosion protection

II 2G Ex de IIB T6

Certificates
For gas explosion protection

Conformity to standards

PTB 03 ATEX 1076; IECEx CQM 07. 0011;


PCEC(China)
EN50014:1997+A1+A2; EN50018:2000+A1;EN50019:2000;
IEC 60079-0:2004; IEC 60079-1:2003; IEC 60079-7:2001;

Enclosure material
Enclosure color
Exposed fastener
Rated voltage
Rated current
Degree of protection
Ambient temperature
Components

Copper-free aluminium; powder coated external surface


Grey
Stainless steel
max. 415V AC
10A
IP65
-20+55
1. HA pushbutton technical data on P4/12;
2. HD indicator technical data on P4/14;
3. HK switch technical data on P4/16;
4. BB8050 ammeter technical data on P4/49;
5. BB8050 voltmeter technical data on P4/49.

Cable entries
Cable gland(optional)
Mounting

Bottom, M  x 1.5 plug. Please see the selection table on P4/9


DQM-I (Ex e) is recommended. Please see P7/1718.
1. Please specify the number and size of entries (applicable for surface type only).
2. Standard mounting is surface type.
3. For pole type, only G1entry is applicable.

Accessories and parts


Description

Illustration

Material

Ordering code

Weight (kg)

Stainless steel

40032

0.06

Hinge

Dimension drawings (all dimensions in mm) - subject to alteration

Enclosure I (Surface type)

4/10

Enclosure II (Surface type)

General Catalogue 01.01.2010

http:// www.waromgroup.com

Control Stations (Ex de IIB)


BZC Series Explosion-proof Control Stations

Dimension drawings (all dimensions in mm) - subject to alteration

Enclosure III (Surface type)

Enclosure V (Surface type)

Enclosure IV (Surface type)

Enclosure VI (Surface type)

Enclosure VII (Surface type)

Pole type (for enclosure I, II, III, IV only)

General Catalogue 01.01.2010

http:// www.waromgroup.com

4/11