ValvesSensorsSystems measurIT technologies

Flowmeters - liquid & gas,


Level gauges, switches, transmitters
Thermal energy meters
Flow switches
Pressure & temperature switches
Pressure sensors
Concentration / density analyzers
Refractometers
pH sensors
Suspended solids & turbidity sensors
Diary product spill monitors
OilSpy oil spill detectors
Humidifiers
Dehumidifiers
Humidity, temp., lux radio monitoring
TESTO measurement instruments
Calibrators

SERVICES:
Flowmeter HIRE-easy to use, non-invasive
ON-SITE flow measurements
Flowmeter DEMO - see how to do it!

MeasurIT Technologies Ltd. distribute and support valves and sensors


for industries such as Pharmaceutical, Biotechnology, Food & Beverage,
Power Generation, Mining, Water & Wastewater.

Our products continue to serve demanding industrial applications since 1995.

We also offer non-invasive on-site flow measurements


and flowmeter HIRE service.

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963
FLEXIM_Fluxus_G_en_V5_091217 23.12.2009 12:56 Uhr Seite 1

FLUXUS® G
______

Non-Invasive
Gas Flow Measurement
Gas Storage Facilities
______

Gas Transmission
______

Natural Gas Extraction


______

Chemical Industry
______

Petrochemical Industry
______

Offshore
______

Manufacturing Industry
______

Measure from outside


what’s flowing inside
______
FLEXIM_Fluxus_G_en_V5_091217 23.12.2009 12:56 Uhr Seite 2

Non-Invasive
Gas Flow Measurement
with FLUXUS® G
_____

© BEB
Our tradition is innovation
FLEXIM's ultrasonic gas flow meters use the proven ______

clamp-on transit-time correlation technique also Ever since its inception, FLEXIM has
been among the pioneers in the field of
employed for the F series liquid meters. ultrasonic flow measurement. Many years
Special ultrasonic transducers are simply clamped of application experience combined with
innovative concepts and solutions have
onto the outside of the pipe and never come in contact
allowed FLEXIM to extend the scope
with the gas. of the ultrasonic technology to non-
invasive measurement of gases.

The FLUXUS® G series contains a broad variety of


Now, with the FLUXUS® G series,
transmitters and transducers: from basic models for FLEXIM sets a new standard. Special
standard applications up to robust measuring systems transmission technology combined
with powerful software algorithms and
for offshore use or for use in hazardous areas.
intelligent adaptive signal processing
gives these instruments the dependability
you have come to expect from FLEXIM.

2
FLEXIM_Fluxus_G_en_V5_091217 23.12.2009 12:56 Uhr Seite 3

© Pål Rønning
© BEB

Adaptive Signal Processing Wide dynamic


______ range amplifier
In order to maximize the signal to noise ______
ratio, an optimized transmission process The FLUXUS® G measurement amplifier
featuring multipulse excitation was offers a uniquely wide dynamic range by
developed. The versatile measurement including various frequency filters which
algorithm automatically adapts to the are automatically tuned to the appropriate
varying application conditions. Thus, transducer frequency. This is particularly
disturbing factors such as beam dispersal advantageous in the case of clamp-on
and structure-borne pipe noise can be ultrasonic gas flow measurement, which
effectively compensated. has to contend with very low signal levels.

The FLUXUS® G series instruments use


digital signal processing. This enables
them to adapt easily to a great variety of
measuring tasks. Up to 1000 raw signals
per second are transmitted for signal
processing and analysis.

FLEXIM's signal processing algorithms


reflect many years of experience in
extracting desired signals and rejecting
unwanted noise signals. Thus, even weak
signals of only a few μV are reliably
detected and processed.
© BEB

3
FLEXIM_Fluxus_G_en_V5_091217 23.12.2009 12:56 Uhr Seite 4

Superior
Functionality
_____

FLUXUS® G represents the ideal solution Non-invasive


for non-invasive gas flow measurement. measurement
FLEXIM’s non-invasive technology is ______
an advantageous and cost-effective ➔ No contact with the medium,
alternative to conventional methods, therefore no possibility of chemical
particularly with chemically aggressive, attack. No need for expensive special
poisonous or high pressure media. With materials (sour gas applications
their extremely wide turn-down ratios, for example)
the instruments of the FLUXUS® G series ______
register even the smallest flows. ➔ No wear and tear, even with high
flow velocities or with gas containing
particles
______
➔ No clogging of small bore impulse
lines with deposits, condensate,
inhibitors, oil vapours, dust (as
happens when using impulse lines
in the measuring system)
______
➔ Insensitive to dust and humidity
______

4
FLEXIM_Fluxus_G_en_V5_091217 23.12.2009 12:56 Uhr Seite 5

No moving mechanical ➔ ➔ Approved for


or pressure loaded parts explosion hazard
______ areas
➔ Safe and maintenance-free
______
➔ Measurements can be made
even at high operating pressures
______
➔ Unharmed by pressure peaks (for
example at the onset of condensation)
______

Transducers are Precise, bi-directional


mounted on the pipe flow measurement with
______ high measurement
➔ Very cost-effective installation dynamics
______ ______
➔ Easy installation without process ➔ Even minute flows are measurable
interruption ______
______ ➔ Measurement is unaffected by
© BEB

➔ No welding work gas density, viscosity and composition,


______ dust, humidity, temperature or
➔ No risk of leakage pressure
______ ______
➔ Cost-advantageous, especially in ➔ Not sensitive to velocity peaks,
high-pressure applications and for swirling flows or transverse flows
large pipe diameters ______
______ ➔ Long-term stable
➔ Absolutely no pressure loss, measurement results
thus low operating costs ______
______ ➔ High measurement rate,
➔ No pipe diameter reduction, fast response time
therefore no pipe clogging ______
______

5
FLEXIM_Fluxus_G_en_V5_091217 23.12.2009 12:56 Uhr Seite 6

Technical Data
_____

Ultrasonic flow meters natively measure The Transit Time Difference Correlation Principle makes use of the fact
the actual volumetric flow. that the time of flight of an ultrasonic signal is affected by the flow
The transmitters feature an integrated velocity of the carrier medium. Like a swimmer working his way across
flow computer which makes use of a flowing river, an ultrasonic signal travels slower upstream than down-
external temperature and pressure data stream.
to convert the actual volumetric flow into Our instruments work according to this transit-time principle: an ultra-
standard volume (mass) flow based on sonic pulse is sent downstream through the medium, another pulse is
ISO 12213-1. sent upstream. By measuring the transit-time difference, the flow
velocity can be determined. The volumetric flow is then calculated out
In principle, flow measurement is possible of the flow velocity and the pipe parameters.
on all types of gases. However, when
measuring on metal pipes, a certain
minimum pressure is required, depending
on the composition of the gas and the
pipe material. Plastic pipes will support General Technical Data
operation at atmospheric pressure. __________________________________________________________________________________________
Measuring principle: Transit time difference correlation principle
Our application engineers will be __________________________________________________________________________________________
pleased to advise you. Flow velocity: (0.01 to 35) m/s, pipe size dependent
__________________________________________________________________________________________
Repeatability: 0.15 % of reading ± 0.01 m/s
__________________________________________________________________________________________
Accuracy (given a fully Volume flow:
developed rotationally ± 1% to 3 % of reading ± 0.01 m/s, depending on the application
symmetric flow profile) ± 0.5 % of reading ± 0.01 m/s with field calibration
__________________________________________________________________________________________
Measurable gases: Ratio of the characteristic acoustic impedance of the
pipe wall material to that of the gas < 3000
__________________________________________________________________________________________
Operating pressure: Measurement does not restrict
the maximum operating pressure
__________________________________________________________________________________________
Pipe size range: (7 to 1600) mm
__________________________________________________________________________________________
Gas temperature: (–40 to +200) °C, depending on the transducer type
__________________________________________________________________________________________

6
FLEXIM_Fluxus_G_en_V5_091217 23.12.2009 12:56 Uhr Seite 7

Applications
_____

Oil and Gas Chemical Industry

______ ______
Measurement on natural gas pipelines Measurement of synthesized gas
______ ______
Measurement in natural gas storage Gas measurement in the plastics
installations (storage and extraction) production process (high pressure)
______ ______
Management of gas storage facilities Measurement of ethylene, helium
(efficiency maximization, performance and nitrogen
optimization, salt cavern leaching) ______
______
Regulation and control of drilling sites
in natural gas extraction
______
Control of compressor stations Manufacturing industry
______
Dimensioning of extraction sites and ______
drilling probes (efficiency maximization) Measurement of compressed air
______ ______
Measurement of ethane, propane and
hydrogen
______
Measurement of sour gas
______ Service
Measurement for the gas supply industry
______ ______
Measurement of injection gas Supervision of permanently
in the petroleum industry installed meters
______ ______
Allocation and checkmetering Error diagnostics
______ ______
Inventory control / Service and maintenance
Lost and unaccounted for gas analysis ______
______
Measurement of injection media in
gas processing (monoethylamine, TEG, etc.)
Gas storage facility Kalle,

with upgraded instrument.


Ask FLEXIM!
Germany, © RWE

______

7
FLEXIM_Fluxus_G_en_V5_091217 23.12.2009 12:56 Uhr Seite 8

The
Transmitters
_____

A FLUXUS® G Guaranteed user friendly


for all purposes ______
______ No complex and elaborate instructions
Whether for portable use, for rack- are required in order to use the intuitively
mounting or for permanent installation, structured menu of the FLUXUS® G.
or even for offshore use: FLEXIM offers The pipe and material parameters are
the appropriate FLUXUS® G to meet each easily entered, thanks to the internal
measurement challenge. ATEX and FM media and materials data bank.
certified measurement systems for use in Explosion-proof instruments can be
hazardous areas are available. Versatile operated without opening the housing and
process interfaces assure optimal without requiring any additional devices.
integration into the user's process.

Technical Data
__________________________________________________________
Operating temperature:
__________________________________________________________

Measuring channels:
__________________________________________________________

Protection degree acc. to EN60529:


__________________________________________________________
Explosion protection in:
__________________________________________________________
Inputs:

__________________________________________________________

Qutputs:

__________________________________________________________

Calculation of the standard volume


flow according to ISO 12213-1:
__________________________________________________________
Communication interface:
__________________________________________________________

8
FLEXIM_Fluxus_G_en_V5_091217 23.12.2009 12:56 Uhr Seite 9

The Portable All-round Meter The Multi-function Meters The Explosion-proof Experts
FLUXUS® G601 FLUXUS® G704 / FLUXUS® G709 FLUXUS® G800 / FLUXUS® G801

Unmatched in performance, this handy and Permanently installed and freely configurable: FLUXUS® G800 and G801 are ATEX certified
versatile instrument is ideal in support of The FLUXUS® G704 is designed for permanent for use in hazardous areas. The especially
service and maintenance activities. It may installation. With its range of electrical inputs robust G801 is completely seawater-resistant
also be used for the control or even the and outputs, it can handle a variety of process and therefore ideal for offshore applications.
temporary replacement of permanently parameters. Although technically identical to
installed meters. the G704, FLUXUS® G709 is designed for
permanent installation in 19" rack systems.

_________________________________________________________________________________________________________________________________________________________________________
–10 °C to 60 °C –20 °C to 60 °C –20 °C to 50 °C
_________________________________________________________________________________________________________________________________________________________________________

2 1 or 2 1 or 2
_________________________________________________________________________________________________________________________________________________________________________

IP65 G704: IP65 G709: IP20 IP66


_________________________________________________________________________________________________________________________________________________________________________

— ATEX Zone 2, FM Class I Div II for G704 ATEX Zone 1 and 2


_________________________________________________________________________________________________________________________________________________________________________

Standard: — Maximum 4. Available are: temperature —


Multifunctional: 2 x current, 1 x voltage, (Pt 100 / Pt 1000), current, voltage
1 x temperature
_________________________________________________________________________________________________________________________________________________________________________

Standard: 2 x current, 2 x binary A variety of combinations are available from 1 current output, 1 binary output (OC).
Multifunctional: 4 x current, 2 x binary, the following: current (0/4 mA to 20 mA), Also available: 1 or 2 binary outputs (relay),
1 x frequency voltage, frequency, pulse, alarm 1 binary output (OC) and 1 current output
_________________________________________________________________________________________________________________________________________________________________________

Yes Yes Yes


_________________________________________________________________________________________________________________________________________________________________________
HART
_________________________________________________________________________________________________________________________________________________________________________

9
FLEXIM_Fluxus_G_en_V5_091217 23.12.2009 12:56 Uhr Seite 10

The Mounting Fixtures


_____

Two transducers types Robust construction Paired, calibrated


providing a uniquely wide ______ transducers
application range All FLEXIM clamp-on transducers are ______
______ watertight and especially made for use Each pair of transducers has been
All FLUXUS® G transmitters support both in harsh industrial environments. The wet-flow calibrated at the factory. All
lamb wave and shear wave transducers at transducer housings are made of PEEK calibration data is stored in a transducer-
all transducer frequencies. In this way the or PPSU with stainless steel protection resident non-volatile memory and is
measuring system can be optimized to the caps. Robust construction and rugged automatically transferred to the trans-
process. The Lamb wave transducer is wiring guarantee long-term stability and mitter upon connection. Consequently,
ideal for high velocity gas measurement as measuring reliability. parameterization errors are eliminated
found in natural gas pipelines. The shear and there is never a need for a zero
wave transducer covers a wide range of adjustment.
pipe diameters and wall thicknesses. It’s
the best choice for mobile measurement
and application diagnostics, as well as for
thick-wall pipes.

10
FLEXIM_Fluxus_G_en_V5_091217 23.12.2009 12:56 Uhr Seite 11

Our application engineers will


be glad to offer you expert advice.
Call for an application review today!

Robust transducer General Technical Data of the Transducers


mounting fixtures ____________________________________________________________________________________________
______ Application range*: Shear wave transducers: Transducers available for diameters from
The Variofix mounting fixtures hold the 15 to 1100 mm. A minimal pipe wall thickness is required.
transducers safely in place and ensure ____________________________________________________________________
continuous and constant contact pressure Lamb wave transducers: Transducers available for diameters
between the transducers and the pipe from 7 to 1600 mm and wall thicknesses from 0,5 to 23 mm.
surface, even if temperature variations Each transducer type is assigned to a given wall thickness range.
cause the pipe diameter to change. Made _____________________________________________________________________________________________
of stainless steel, they are corrosion-proof Operating temperature: Gas temperature and ambient temperature: between –40 to 200 °C,
and wear resistant. The transducers can depending on the transducer type.
be removed and remounted onto the _____________________________________________________________________________________________
Variofix rail without readjustment. Use in explosion Transducers for ATEX Zone 1 and 2 as well as for FM Div 2
hazard area: available
The offshore mounting rail is made to _____________________________________________________________________________________________
meet the highest operational demands – Explosion protection Depends on the transducer type and on the atmosphere type.
right down to the very last bolt. temperature: The explosion protection range is usually wider than the operating
The rail is seawater-proof and provides temperature range.
your transducers the highest protection _____________________________________________________________________________________________
they deserve. Protection degree IP 56, IP 65, IP 67, IP 68
acc. to EN60529:
____________________________________________________________________________________________
Material: PPSU or PEEK with stainless steel caps
_____________________________________________________________________________________________
*: the specified range is valid for natural gas in steel pipes,
under the conditions defined in the specification sheets.