ADDENDUM - SUGGESTED WIRING CONFIGURATION


ADDENDA - SCHMA DE BRANCHEMENT SUGGR

REGULAR INSTALLATION

HARDWARE VERSION
VERSION MATRIELLE
MINIMUM

FIRMWARE VERSION
VERSION LOGICIELLE

79.[31]
UNIT OPTION
OPTION UNITE

1X

This manual may change without notice.


www.fortinbypass.com for latest version.
Ce Guide peut faire lobjet de changement
sans pravis. www.fortinbypass.com pour la
rcente version.

TOYOTA/LEXUS/SUBARU MINIMUM

Program bypass option:


Programmez loption du contournement:

OEM Remote
monitoring

Foot-Brake Status

Hand-Brake Status

Power lift gate

Trunk Status

Parking Lights

Door Status

Trunk (open)

Tachometer

Disarm

Impreza
WRX
WRX - STi
XV-Crosstrek

2014-2016
2014-2015
2012-2016
2015-2016
2015-2016
2013-2016

Arm

XT

Unlock

YEARS
ANNES

Lock

VEHICLE
VEHICULES
SUBARU
Forester

Immobilizer bypass
Contournement
dimmobilisateur

Vehicle functions supported in this diagram (functional if equipped) | Fonctions du vhicule supportes dans ce diagramme (fonctionnelles si quip)

C1

DESCRIPTION

OEM Remote status (Lock/Unlock)


monitoring
Suivi des status (Verrouillage/Dverrouillage) de la tlcommande dorigine

Parts required (Not included)

Pice(s) requise(s) (Non incluse(s))

2X 1 AMP Diode (Manual transmission only)

2X Diodes 1 AMP (Transmission manuelle seulement)

FLASH LINK UPDATER 2

FLASH LINK UPDATER 2

Microsoft Windows Computer &


Internet connection

Ordinateur Microsoft Windows &


connection Internet

This guide may change without notice. See www.fortin.ca for latest version.
Ce guide peut faire lobjet de changement sans pravis. Voir www.fortin.ca pour la rcente version.

Page 2 / 7

DESCRIPTION | DESCRIPTION
BCM
Behind fuse box
BCM
larrire de la bote fusibles

Ignition harness
Harnais dignition
(+)STARTER
(+)12V

(+)STARTER2

(-)HORN

(~)IMO

(-)PARKING LIGHTS
(~)CAN
HIGH

(~)CAN LOW

(~)DOOR LOCK DATA

()SECURITY LED

(+)ACC.

(+)IGN.

(+)IGN.2

This guide may change without notice. See www.fortin.ca for latest version.
Ce guide peut faire lobjet de changement sans pravis. Voir www.fortin.ca pour la rcente version.

Page 3 / 7

AUTOMATIC TRANSMISSION WIRING CONNECTION | SCHMA DE BRANCHEMENT TRANSMISSION AUTOMATIQUE


A14
(-)
(-)
A13
A12 (+/-)
A11 (+)
A8
(-)
A5
(-)
A4
(-)
A3
(-)
A2
(-)

HAND BRAKE
TRUNK RELEASE
TACHOMETER
FOOT BRAKE
GROUND OUT WHILE RUNNING
TRUNK
DOOR
UNLOCK
LOCK

ALWAYS REQUIRED
TOUJOURS REQUIS

IN RS9
OUT RS10
IN RS12
IN RS13
OUT RS14
IN RS15
IN RS16
OUT RS17
OUT RS18

WITH | AVEC DATA-LINK:

RS7b
RS7a
RS6a
RS6
RS5
RS4
RS3
RS2
RS1

REMOTE
STARTER
DMARREUR
DISTANCE

OUT
STARTER2
OUT
STARTER1
IN/OUT
IGNITION2
IN/OUT
IGNITION1
OUT
ACCESSORY
OUT PARKING LIGHTS
OUT PARKING LIGHTS
IN
12V BATTERY

Ground | Masse

(+)
(+)
(+)
(+)
(+)
(+)
(-)
(+)
(-)
Fuse
Fusible

WITH | AVEC DATA-LINK:


Direct connection
Branchement directe

NOT REQUIRED WITH


DATALINK
NON REQUIS EN
DATA-LINK

A1

Y
(+) Ignition
P
(-) Lock
(-) Unlock P/W
G
(-) Door Status
W
(-) Trunk Status
O
O/B
D.B
(-) Ground While Running
R/B
(~)IMO L.B/B
B
(+) Foot Brake
P
(-/+) Tachometer
(-) Trunk Release Y/B
(-) Hand Brake B/W
P/B
P/Y
Security led - car side G/W
G/R
Security led - BCM side
W/B
L.B
(~)Door lock DATA

D4

A17
Cut

Forester
WRX-STI
Impreza
WRX
XV
Crosstrek

A10
Cut

In
In
In
Out
Out
In
In
In
In
Out
Out
In
Out
Out

A20/D6
(~)DOOR
LOCK DATA

Brown/Red
Brun/Rouge

Green
Vert

Brown/Red
Brun/Rouge

Red
Rouge

White/Blue
Blanc/Bleu

25 24

23 22 21 20 19 18

31 30

29 28

Back view White 31-pin


connector
Vue de dos Connecteur
Blanc, 31-pins.

D3

C5
C4
C3
C2
C1

B
G/B
CAN LOW
G
CAN HIGH
O/B
O/G

D6 W/R

D D5
D4

W/B
W/G
D3 Y/R
D2 Y/B
D1 Y/G

(~)Door lock DATA


(~)Door lock DATA
(~)IMO
(~)IMO

(+)12V

RS7b
(+)STARTER2

Pink
Rose

Yellow
Jaune

White
Blanc

Blue
Bleu

White
Blanc

White
Blanc

C4
(~)CAN
LOW

RS3
(-)PARKING
LIGHTS

RS8b
(+)IGNITION2

Red/Yellow
Red
Rouge/Jaune Rouge

Blue
Bleu

Lt.Green
Vert Ple

Red
Rouge

Blue
Bleu

Black/Blue
Noir/Bleu

BCM
Behind fuse
box
BCM
larrire de
la bote
fusibles

C3
(~)CAN
HIGH

(~)IMO

17 16 15 14 13 12 11 10 9

27 26

D1

A18
()SECURITY LED

17 16 15 14 13 12 11 10 9 8

A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20

1
8

27 26

25 24

23 22 21 20

34 33

35 34

33 32

31 30 29 28

Back view White 34-pin


connector
Vue de dos Connecteur
Blanc, 34-pins.

Back view White 35-pin


connector
Vue de dos Connecteur
Blanc, 35-pins.

RS7a
(+)STARTER1

RS5
RS6
(+)ACCES (+)IGNI-SORY
TION1

Brown
Brun
Black/White
Vert Ple

Red
Rouge

Green
Vert

Yellow
Jaune

Green
Vert

19 18 17 16 15 14 13 12 11 10 9 8

27 26 25 24 23 22 21 20 19 18
32 31 30 29 28

RS2

Back view - White


8-pin connector
Ignition harness
Vue de dos Connecteur Blanc,
8-pins.
Harnais dignition

This guide may change without notice. See www.fortin.ca for latest version.
Ce guide peut faire lobjet de changement sans pravis. Voir www.fortin.ca pour la rcente version.

Page 4 / 7

MANUAL TRANSMISSION WIRING CONNECTION | SCHMA DE BRANCHEMENT TRANSMISSION MANUELLE


A14
(-)
(-)
A13
A12 (+/-)
A11 (+)
A8
(-)
A5
(-)
A4
(-)
A3
(-)
A2
(-)

HAND BRAKE
TRUNK RELEASE
TACHOMETER
FOOT BRAKE
GROUND OUT WHILE RUNNING
TRUNK
DOOR
UNLOCK
LOCK

ALWAYS REQUIRED
TOUJOURS REQUIS

IN RS9
OUT RS10
IN RS12
IN RS13
OUT RS14
IN RS15
IN RS16
OUT RS17
OUT RS18

WITH | AVEC DATA-LINK:

RS7b
RS7a
RS6a
RS6
RS5
RS4
RS3
RS2
RS1

REMOTE
STARTER
DMARREUR
DISTANCE

OUT
STARTER2
OUT
STARTER1
IN/OUT
IGNITION2
IN/OUT
IGNITION1
OUT
ACCESSORY
OUT PARKING LIGHTS
OUT PARKING LIGHTS
IN
12V BATTERY

Ground | Masse

(+)
(+)
(+)
(+)
(+)
(+)
(-)
(+)
(-)
Fuse
Fusible

WITH | AVEC DATA-LINK:


Direct connection
Branchement directe

NOT REQUIRED WITH


DATALINK
NON REQUIS EN
DATA-LINK

A1

Forester
WRX-STI
Impreza
WRX
XV
Crosstrek

A10
Cut

Out
Out
In
Out
Out

A20/D6
(~)DOOR
LOCK DATA

Brown/Red
Brun/Rouge

Green
Vert

Brown/Red
Brun/Rouge

Red
Rouge

White/Blue
Blanc/Bleu

25 24

23 22 21 20 19 18

31 30

29 28

Back view White 31-pin


connector
Vue de dos Connecteur
Blanc, 31-pins.

D3

C5
C4
C3
C2
C1

B
G/B
CAN LOW
G
CAN HIGH
O/B
O/G

D6 W/R

D D5
D4

W/B
W/G
D3 Y/R
D2 Y/B
D1 Y/G

RS8b
(+)IGNITION2

Lt.Green
Vert Ple

RS7b
(+)
CLUTCH
Purple/Green
Mauve/Vert

Black/Blue
Noir/Bleu

Lt.Green
Vert Ple

C4
(~)CAN
LOW

RS3
(-)PARKING
LIGHTS

Red/Yellow
Red
Rouge/Jaune Rouge

Blue
Bleu

Red
Rouge

Blue
Bleu

BCM
Behind fuse
box
BCM
larrire de
la bote
fusibles

C3
(~)CAN
HIGH

(~)IMO

17 16 15 14 13 12 11 10 9

27 26

D1

A18
()SECURITY LED

17 16 15 14 13 12 11 10 9 8

A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20

(~)Door lock DATA


(~)Door lock DATA
(~)IMO
(~)IMO

1A Diode

D4

A17
Cut

In
In
In
Out
Out
In
In
In
In

1A Diode

Y
(+) Ignition
P
(-) Lock
(-) Unlock P/W
G
(-) Door Status
W
(-) Trunk Status
O
O/B
D.B
(-) Ground While Running
R/B
(~)IMO L.B/B
B
(+) Foot Brake
P
(-/+) Tachometer
(-) Trunk Release Y/B
(-) Hand Brake B/W
P/B
P/Y
Security led - car side G/W
G/R
Security led - BCM side
W/B
L.B
(~)Door lock DATA

1
8

27 26

25 24

23 22 21 20

34 33

35 34

33 32

31 30 29 28

Back view White 34-pin


connector
Vue de dos Connecteur
Blanc, 34-pins.

Back view White 35-pin


connector
Vue de dos Connecteur
Blanc, 35-pins.

RS7b
(+)STARTER2

Pink
Rose

Yellow
Jaune

White
Blanc

Blue
Bleu

White
Blanc

White
Blanc

RS2

RS7a
(+)STARTER1

RS5
RS6
(+)ACCES (+)IGNI-SORY
TION1

Brown
Brun
Black/White
Vert Ple

Red
Rouge

Green
Vert

Yellow
Jaune

Green
Vert

19 18 17 16 15 14 13 12 11 10 9 8

27 26 25 24 23 22 21 20 19 18
32 31 30 29 28

(+)12V

MANUAL TRANSMISSION
TRANSMISSION MANUELLE
Back view - White 2-pin
connector. Upper clutch
switch
Vue de dos - Connecteur
Blanc, 2-pins. Commutateur
dembrayage du haut.

Back view - White


8-pin connector
Ignition harness
Vue de dos Connecteur Blanc,
8-pins.
Harnais dignition

This guide may change without notice. See www.fortin.ca for latest version.
Ce guide peut faire lobjet de changement sans pravis. Voir www.fortin.ca pour la rcente version.

Page 5 / 7

DCRYPTOR
PROGRAMMING
PROCEDURE
| PROCDURE
DE PROGRAMMATION
AVEC DCRYPTEUR
PROGRAMMING
PROCEDURE
1/2 | PROCDURE
DE PROGRAMMATION
1/2
Parts required (not included)

Pices requises (non incluses)

1x

1x

1x
1x

FLASH LINK UPDATER 2,


FLASH LINK MANAGER software

Microsoft Windows Computer with


Internet connection

1x
1x

FLASH LINK UPDATER 2,


Programme FLASH LINK MANAGER
Ordinateur Microsoft Windows avec
connection Internet

1
Press and hold the
programming button:
Connect the 4-PIN Data-link
harness (Black connector).

x1

HOLD


The Blue, Red, Yellow and
Blue & Red LEDs will
alternatively illuminate.

LED may differ depending on the module casing.


Lapparence des DELS peut diffrer selon le botier du module.

2
RELEASE

ON

BLUE
BLEU

ON

RED
ROUGE

Appuyez et maintenir
enfonc le bouton de
programmation: Branchez le
harnais Data-Link 4-Broches
(connecteur Noir)


Les DELs Bleue, Rouge,
Jaune et Bleue & Rouge
s'allumeront alternativement.

Release the programming


button when the LED are
BLUE & RED.

Relchez le bouton de
programmation quand les
DELs sont BLEU et ROUGE.

If the LED are not solid BLUE


and RED disconnect the 4Pin connector (Data-Link)
and go back to step 1.

Si le DEL ne sont pas BLEU et


ROUGE dbranchez le
connecteur 4 pins (Data-Link) et
allez au dbut de l'tape 1.

Insert the required remaining


connectors.

Insrez les connecteurs requis


restants.

Press and release the


programming button six time
(6x).

Appuyez et relchez 6 fois le


bouton de programmation.

4
PRESS X6

x6

PAUSE 5XFLASH PAUSE

PRESS

...
...
...

5
START


The RED and BLUE LED
will flash 5 times each
second.

FLASH 10X

PUSH

STA
RT

START

LO

CK

Start the engine.


ACC ON


Les DELs ROUGE et
BLEUE clignotent 5 fois
chaque seconde.

Dmarrez le moteur

FLASH 10X
FLASH
RAPIDLY


The RED LED will flash
rapidly 10x times.
Key bypass programmed.


La DEL ROUGE clignotera
10x fois rapidement.
Contournement de cl
programm.


Wait for the BLUE LED will
flash rapidly.


Attendre que la DEL
BLEUE clignote rapidement.


Wait for the YELLOW and
RED LED will alternate.


Attendre que les DELs
JAUNE et ROUGE alternent.

Turn the key to the


OFF position.

Tournez la cl la
position Arrt (OFF).

ALTERNATE | ALTERNE

6
F

START

LO

CK

OF
ACC ON

PUSH

CONTINUED NEXT PAGE | CONTINUEZ LA PAGE SUIVANTE

This guide may change without notice. See www.fortin.ca for latest version.
Ce guide peut faire lobjet de changement sans pravis. Voir www.fortin.ca pour la rcente version.

Page 6 / 7

KEY BYPASS PROGRAMMING PROCEDURE 2/2 | PROCDURE DE PROGRAMMATION CONTOURNEMENT DE CL 2/2


7
EVO-ALL

Disconnect the Data-Link (4-pins) connector and after


all the remaining connectors.
Dbranchez le connecteur Data-Link (4-pins) et ensuite
tous les connecteurs restants.

Parts required (not included)


Pices requises (non incluses)

Connect the module to the


FLASH LINK UPDATER 2
and visit the DCryptor menu
in the Flash-Link Manager.

FLASH LINK
UPDATER 2
9

Branchez le module au
FLASH LINK UPDATER 2
et visitez le menu DCryptor
dans le Flash-Link Manager.

FLASH LINK
UPDATER 2
FLASH LINK MANAGER
SOFTWARE | PROGRAMME

Microsoft Windows
Computer with
Internet connection
Ordinateur Microsoft
Windows avec
connection Internet

AFTER DCRYPTOR PROGRAMMING COMPLETED


Go back to the vehicle and reconnect the 4-Pin (Data-Link)
connector and after, all the remaining connector.

EVO-ALL

APRS LA PROCDURE DE PROGRAMMATION


DCRYPTOR COMPLETE : retournez au vhicule et
rebranchez le connecteur 4-pins (Data-Link)
et aprs, tous les connecteurs du EVO-ALL.

The module is now programmed.


Le module est programm.

REMOTE STARTER / ALARM VERIFICATION


PROCEDURE | PROCDURE DE VRIFICATION
DU DMARREUR DISTANCE / ALARME

Test the remote starter. Remote start the vehicle.


Testez le dmarreur distance. Dmarrez le vhicule
distance.

Page 7 / 7

ALL
HARDWARE VERSION
FIRMWARE VERSION
Date: xx-xx

EVO-ALL

INTERFACE MODULE

PATENTS PENDING US: 2007-228827-A1

Made in Canada

Service No :

www.fortinbypass.com

000 102 04 2536

Module label | tiquette sur le module

Notice: Updated Firmware and Installation Guides


Updated rmware and installation guides are posted on our web site on a regular
basis. We recommend that you update this module to the latest rmware and
download the latest installation guide(s) prior to the installation of this product.
Notice: Mise jour microprogramme et Guides dinstallations
Des mises jour du Firmware (microprogramme) et des guides dinstallation
sont mis en ligne rgulirement. Vriez que vous avez bien la dernire version
logiciel et le dernier guide dinstallation avant linstallation de ce produit.

WARNING
The information on this sheet is provided on an (as is) basis with no representation or warranty of accuracy whatsoever.
It is the sole responsibility of the installer to check and verify any circuit before connecting to it. Only a computer safe
logic probe or digital multimeter should be used. FORTIN ELECTRONIC SYSTEMS assumes absolutely no liability or
responsibility whatsoever pertaining to the accuracy or currency of the information supplied. The installation in every case
is the sole responsibility of the installer performing the work and FORTIN ELECTRONIC SYSTEMS assumes no liability
or responsibility whatsoever resulting from any type of installation, whether performed properly, improperly or any other
way. Neither the manufacturer or distributor of this module is responsible of damages of any kind indirectly or directly
caused by this module, except for the replacement of this module in case of manufacturing defects. This module must be
installed by qualied technician. The information supplied is a guide only. This instruction guide may change without
notice. Visit www.fortinbypass.com to get the latest version.
MISE EN GARDE
Linformation de ce guide est fournie sur la base de reprsentation (telle quelle) sans aucune garantie de prcision et
dexactitude. Il est de la seule responsabilit de linstallateur de vrier tous les ls et circuits avant deffectuer les connexions.
Seuls une sonde logique ou un multimtre digital doivent tre utiliss. FORTIN SYSTMES LECTRONIQUES nassume
aucune responsabilit de lexactitude de linformation fournie. Linstallation (dans chaque cas) est la responsabilit de
linstallateur effectuant le travail. FORTIN SYSTMES LECTRONIQUES nassume aucune responsabilit suite
linstallation, que celle-ci soit bonne, mauvaise ou de nimporte autre type. Ni le manufacturier, ni le distributeur ne se
considrent responsables des dommages causs ou ayant pu tre causs, indirectement ou directement, par ce module,
except le remplacement de ce module en cas de dfectuosit de fabrication. Ce module doit tre install par un technicien
quali. Linformation fournie dans ce guide est une suggestion. Ce guide dinstruction peut faire lobjet de changement
sans pravis. Consultez le www.fortinbypass.com pour voir la plus rcente version.
Copyright 2006-2014, FORTIN AUTO RADIO INC ALL RIGHTS RESERVED PATENT PENDING

TECH SUPPORT
Tl: 514-255-HELP (4357)
1-877-336-7797