You are on page 1of 43

PROPOSEDDESIGN

TECHNICALSITESURVEYREPORT
(TSSR)

INFRASTRUCTUREDEVELOPMENTOF
CELLULARTELECOMMUNICATIONNETWORKS

Survey
SiteName
SiteID

Region
Branch
Project/Scope

Number/Version

TSSR Form Ver.7.5

:
:
:
:
:
:

Modernization
GRAHAFAMILY3
20SBY059

EJBN
SURABAYA
BufferStock2

Date 11.04.2012

Check List Page

1(1/43)

20SBY059_GRAHAFAMILY3

1.
1.1.

SITE SURVEY CHECKLIST


Site Information

Tick the box (9), when checked.

SITENAME:GRAHAFAMILY3

Branch:SURABAYA

SITEID:20SBY059

SITETYPE:

AreaCoverage

DenseUrban

Urban

BTSTypeExisting

UltraSite
BS24X

Metrosite
FlexiMultiRadio

SiteOwnership

ISAT

collocatewith
otherOperator

SubUrban

InBuilding
FlexiBTS
Others:

Others,specify

JL. RAYA LAKARSANTRI 28 RT 04/02, SURABAYA

SITEADDRESS:

TEL:

CONTACTPERSONS:

SiteAccessCondition

24hours

limited,specify..

SiteAccessKey

RegionalSystemKey

Ifothers,where..

SiteKeeper

Name:

Phn:

SiteContractStatus:

Start:..../..../....End:..../..../....

Communityproblem

Yes,
Pleaseexplain:..
.
No

SURVEYDONEBY:

1.Name:AhmadSyafiiPhn:

Company:PT.PERDANAKOMSELMANDIRISigned:

SURVEYDONEBY:

2.Name:Phn:

Company:Signed:

DATE:

11/ 04/12

(dd/mm/yy)

Note:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 2(43)

20SBY059_GRAHAFAMILY3

1.2.SiteLocation
Tickthebox(9),whenchecked.

COORDINATES:

718'2.86"S

11238'6.00"E

ELEVATION:

25

DISTANCEFROMREGIONALCITY:

11.5

km SurabayaCity

DISTANCEFROMMAINROAD

0.03

km

ROADCONDITIONS:

Good

MATERIALSTORAGE:

ONSITE:

YES

NO

MAPS:

ROADMAPVERTION/INDEX:

TERRITORIALMAP:

REMARKS:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 3(43)

20SBY059_GRAHAFAMILY3

2.VISUALCHECKLIST
2.1.

CivilWork

Check Point
1.

OK

NOK

NA*

Tower / Mini Tower / Pole is completely erected, no missing or loose members. Assembly is done
according to manufacturers Tower Design Drawings; Height : ___42____ m.
Tower/ Mini Tower/ Pole didirikan dengan sempurna, tidak ada bagian yang hilang ataupun kurang.
Pendirian menara sudah selesai sesuai gambar rencana oleh pabrikator; Ketinggian: ___42_______m

2.

Tower / Mini Tower painted according to ICAO, where applicable.

3.

No structural defects, no sever rust of bolts, no non-standard welding (especially for co-located
sites).

Menara/tower telah dicat sesuai dengan standard ICAO (International Civil Aviation Organization)

Tidak ada cacat pada struktur, tidak ada karat pada baut, tidak ditemukan pengelasan yang tidak baik
(khusus untuk lokasi dengan penggunaan tower bersama)

4.

Climbing ladder is completely installed.


Tangga telah dibangun dengan lengkap

5.

Cable trays (vertical & horizontal) are installed & positioned correctly.

6.

No concerns of over-load on tower, i.e. too many antennas and microwaves, two or more cable
ladders etc. Load-non-conformance to tower name plate (especially for co-located sites).

Tray kabel (vertikal & horisontal) telah rapi dipasang dan ditempatkan dengan benar

Pertimbangan beban berlebih pada tower, contoh, terlalu banyak antenna dan microwave, terdapat dua atau
lebih kabel ladders, dll. Pembebanan tersebut tidak sesuai dengan yang tercantum pada papan informasi.
(Khusus untuk penggunaan pada tower bersama)

7.

Antenna mounting poles are positioned correctly.


Tempat pemasangan antena ditempatkan dengan benar

8.

BTS base frame is constructed according to As Planned Drawings.


BTS-base frame dibangun sesuai dengan gambar rencana

9.

Tower leg stubs grouted with non-shrinking grout.

10.

Backfilling of the foundation is completed.

Kaki tower telah digrouting dengan bahan sesuai standar


Timbunan tanah pada pondasi telah selesai.

*NA = Not Applicable (dipilih jika item tidak digunakan untuk tipe site tertentu)

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 4(43)

20SBY059_GRAHAFAMILY3

2.2.Building
Tickthebox(9),whenchecked.

EXISTING/Rooftop:

YES

NO

DIMMENTIONofROOFTOP

mx M

OVERALLCONDITIONtoADDADDITIONALEQUIPMENT:

OK

NOK

CUSTOMERSHELTERAVAILABLE:

YES

NO

CUSTOMEROUTDOOREQUPMENTAVAILABLE:

YES

NO

DRAWINGSAVAILABLE:

FLOORLAYOUTS:

YES

NO

OTHERS:

HEIGHT:(typical:1floor=3.5m)

ACCESSTOROOF:
Stairs,
Lift
Escalator
others,Pleasenote:.

MATERIALLOADING,
Anyspecialtoolrequired?:
PleaseSpecify:

Yes

No

REMARKS:

2.3.Surroundings
Tickthebox(9),whenchecked.

SURROUNDINGBUILDINGS:

YES

NO

YES

NO

HIGHERTHANTHESELECTEDBUILDING:

DISTANCEFROMTHESELECTEDSITE:

km

DIRECTION:

deg.

POWERLINESNEARBY:

YES,___________m.

NO.

ANYEXISTINGTOWERUSEDBYOTHEROPERATORS:

YES,distance_________m
NameofOperator:_____________

NO

ONTHEROOFTOPOFTHESELECTEDBUILDINGOTHEREQUIPMENT(antennas,poles,...)
FROMTHEOTHEROPERATORS:Nameofoperator______________________

YES

NO

ENOUGHSPACEFORNOKIASIEMENSNETWORKSSIEMENS
NETWORKSANTENNAS/POLESLEFTOVER:

YES

NO

REMARKS:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 5(43)

20SBY059_GRAHAFAMILY3

2.4

EquipmentRoom

SHELTEREXISTINGTYPE:
DIMENSIONS:

Indoor

Outdoor

2.8

m(W)

5.00

m(L)

m(H)

PROPOSESPACENEW

UltrasiteIndoor

FlexiEDGE1stack

19rackcustomize

EQUIPMENT:

UltrasiteOutdoor

FlexiEDGE2stack

FlexiMultiRadio

UltrasiteSupreme(3G)

FlexiWCDMA

BTS24X

SpaceavailableforNewShelterequipment DistancefromNewEquipmenttoRectifier:_________________m
(aspropose)?
DistancefromNewEquipmenttoFEP:_____________________m

YES No

SPACE:

DistancefromNewEquipmenttoRectifier:_________________m

SpaceavailableforNewShelterless
equipment(aspropose)?
YES No
SpareHoleonHBeam?
YES No

HoledimensiononHBeam:________________________m
DistancebetweenHoleonHBeam:_______________________m

SHIFTING

AnyEquipment/CableneedtoShifttoget
space?
YES No
EquipmentNameandQty(cabinet)
_Rack19

DidgetpremisefromIndosatRegionaltoshiftequipment?

YES

No

IndosatNamethatallow:

__________________________________

DISMANTLINGand AnyEquipmentneedtodismantled/Swaped DidgetpremisefromIndosatRegionaltodismantleequipment?


SWAP
togetspace?
YES No
YES No
IndosatNamethatallow:
EquipmentNameandQty(cabinet)
______________________________
__________________________________

MATERIALS:

RAISEDFLOOR

HBeam

BRICKWALL

Antistaticvinylfloor(CKDShelter)

ROOMTEMPERATURE:

OK:

NOK

AIRCONDITIONER:

Available
: Unit_____2_________
NotAvailable
: Capacity___________

Remark:UseexistingAC/ ReplaceexistingAC/

AddNewAC

VENTILATIONFAN:

YES

NO

NEWNEEDED:

LIGHTING:

YES

NO

NEWNEEDED:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 6(43)

20SBY059_GRAHAFAMILY3

INDOOR
GROUNDING
BAR(IGB):

EXISTING

NEWNEEDED:

IGB#1
TotalHole____14______
RemainHole____8______

IGB#2
TotalHole______14_____
RemainHole_____8_____

Quantity:____________
TotalHole:____________
RemainHole:__________

CABLELADDER/TRAY

EXISTING,Dimmenstion(Width):____400________mm,
SpaceAvailablefornewCable:
YES No
PROPOSENEW,Dimmenstion(Width)________mm,Length____________mm

DRAWINGSAVAILABLE:

FLOORLAYOUT:

YES

NO

OTHERS:

REMARKSOFEQUIPMENTROOM:

ForOutdoorSite,alsomeasureholedimensiononHBeam,makeitmatchwithourBTSholedimension.Pleasebeinfomed
atDrawing

2.5.

Mechanical&Electricalworks

Check Point

1.

2.
3.
7.
9.

OK

NOK

NA*

KWH system is installed, lockable & functioning correctly


Sistem KWH telah terpasang, dapat dikunci dan bekerja dengan benar

All circuit breakers and wires are installed and labeled properly
Semua Circuit Breaker dan kabel telah di pasang dan di beri label yang sesuai

Lights are installed and working properly


Semua lampu terpasang dengan lengkap dan berfungsi dengan baik

All steel work (cable tray, ladder, lightning protection) grounding is installed correctly
Pentanahan untuk semua pekerjaan baja telah terpasang dengan benar

Generator equipment available and functioning properly


Genset tersedia dan berfungsi dengan baik

*NA = Not Applicable (dipilih jika item tidak digunakan untuk tipe site tertentu)

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 7(43)

20SBY059_GRAHAFAMILY3

2.6.ACandDCDistribution
Tickthebox(9),whenchecked.

ACSOURCESAVAILABE: YES NO TAKEFROMSEPARATEROOM___________(yes/No)


Distancefromequipementroom/OudoorBTS:_________________m

PHASES:___3____Phase(3or1)

ACPOWERSTABILITY
stable/
RefertoIndosatauthorizationperson(SiteKeeper)

unstable

ACPDBBOXAvailable

YES,DistancefromproposedBTS:_____1,8______m,fromrectifier_____0,6_____m
MCBcapacity,Main_3x___25___xAmp,
ProposeforNewCB:
Yes_______________xAmp No
Anyspaceavailable:_____Yes________(yes/No)

NO(ProposeNEW),
DistancefromMainSources(KWHMeter)_________m,
Distancefromproposerectifier________m,
Supportrequired__________________(pole,wallmountetc.)
ACJunctionBoxtoshareACpowerbetweenExistingACPDBandNewACPDB:
Yes No,
DistancefromKWHmeterm,position(Indoor/Outdoor)

Arrester

KWHMeterExisting:

Number/Version: tssr.ver.7

KHWMeter

ACPDB

Yes

No,brand=obo,type

Yes

No,brand=obo,type

YES
MCB=.....3.....x35amp
AmperExistingLoad(measured)
R=2..amp
S=3.2.amp
T=4.6....amp

UpgradeNeeded
Yes,KWH
No

Date: 11.04.2012

Check List Page 8(43)

20SBY059_GRAHAFAMILY3

RECTIFIERAVAILABE: YES NO
SEPARATEROOMwithProposeBTSEquipment____yes_______(yes/No).
Distancefromproposeequipement:_____2_______m,
Brand:__ POWER ONE__TypePPS16.48PCS+10XFMP16 Voltage:____48___Phase(Volt),
ExistingRectifiercapacity:
Modules:Qty_6_x_32_A,TotalLoadCapacity:__160__A
LoadCurrent:__96.4__A,RemainCurrent:_96__A
MaximumCapacityofModulesrectifier:Qty_10_unit

MCBCapacity:PleaseFillInMCBcapacityatRectifier

MCB1
(A)

MCB2
(A)

MCB3
(A)

MCB4
(A)

MCB5
(A)

MCB6
(A)

MCB7
(A)

MCB8
(A)

MCB9
(A)

MCB10
(A)

63

63

80

10

10

10

10

10

10

10

Load

ON

ON

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

MCB11
(A)

MCB12
(A)

MCB13
(A)

MCB14
(A)

MCB15
(A)

MCB16
(A)

MCB17
(A)

MCB18
(A)

MCB19
(A)

MCB20
(A)

10

16

16

Load

ON

OFF

OFF

RectifierCapacityforNewBTS
NoNeedUpgrade
NeedUpgradeModules:..Modules
NeedAddNewMCB:A
NeedNewRectifier

BatteryAVAILABE: YES NO
ExistingBatteryCondition:
No.ofbank3..,capacityperbank=180..amp/hour
Totalcapacitybattery=540..amp/hour(no.ofbank3x180capacityperbank)

BatteryCapacityforNewBTS
NoNeedUpgrade
NeedUpgradeBattery:..Bank

DCPDBBOXAvailable

YES,DistancefromproposedRectifier:_________m,MCBCapacity:________A
ProposeforNewCB:________xAmp,Anyspaceavailable___________(yes/No)
NO(ProposeNEW),Distancefromrectifier_________m,Distancefrompropose
equipment________m,Supportrequired__________________(pole,wallmountetc.)

PleaseFillInMCB/CBcapacityatRectifier

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 9(43)

20SBY059_GRAHAFAMILY3

REMARKSOFAC/DCDISTRIBUTION:

2.7.FEP
Tickthebox(9),whenchecked

WALLTHROUGH:

EXISTINGDim:Qty_____x_________(7/8,15/8ec)hole.
SPAREDim:Qty___________x_______________(7/8,15/8ec)hole.

NEW,Propose.Qty_________x______(7/8,15/8ec)hole.
(6hole/8hole/12hole)

CableBootType:
7/81hole
7/82hole
7/83hole
15/81hole

REMARKSOFCABLEFEP:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 10(43)

20SBY059_GRAHAFAMILY3

2.8.Earthing/GroundingforEquipment
Tickthebox(9),whenchecked.

TYPE:

+EARTH

EARTH

FLOATING

EARTHINGBUSBAR:

GroundingSystemAvailibility Yes No,reason


..

ExistingResistance(ohm)

=.(ohm)

GroundingBarExisting

Existing(yes/No)

NoExisting/ProposeNew

IGB(Indoor/Outdoor):
TotalHole:14.hole
Spare:8.hole

Qty:____________pcs___________Hole

HorizontalBusbar:
TotalHole:14.hole
Spare:8.Hole

BottomBusbaratVertical
Tray:
TotalHole:14.hole
Spare:8.Hole

MiddleBusbaratVertical
Tray:
TotalHole:14.hole
Spare:8.Hole

TopBusbaratVerticalTray:
TotalHole:14.hole
Spare:6.Hole

xxxxx x
x
X

Qty:____________pcs___________Hole

xxxxx x
x
X

Qty:____________pcs___________Hole

BusbarpositionHeight:.M

x
x x x x

X x x x x
X

Qty:___1_________pcs____8______
Hole

BusbarpositionHeight:34m

Qty:____________pcs___________Hole

BusbarpositionHeight:.M

xxxxx x
x
X

Summarygroundingsystemrequirementfor2Gor3G

BakKontrol,busbarneeded,Qty=pcs,..hole

VerticalTray,busbarneeded,Qty=pcs,..hole

HorisontalTray,busbarneeded,Qty=pcs,..hole

FEP/ODBTS,busbarneeded,Qty=pcs,..hole

IGB,busbarneeded,Qty=pcs,..hole

TotalCableGroundingBCC50mm,=.Mtr

REMARKS:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 11(43)

20SBY059_GRAHAFAMILY3

2.9SignalCablesandDistributionFrames
Tickthebox(9),whenchecked

TRANSMISSIONDDF
TotalE1Needed :..16E1......
TotalE1Available :...1E1.....

Detail:
1. Facingto
:SitePERUMDRIYOREJO
E1Capacity :8E1 (Use:2E1/Available:6E1)

2.Facingto
:SiteBSC_CITRALAND
E1Capacity :15E1(Use:1E1/Available:14E1)

3.Facingto
:Site......

E1Capacity :......(Use:....../Available:......)

*Note:Plsaddthenumberifmorethan3facing

LinkTransmisionstatus:

LinkXconnect

SiteOrigin
(............)

Site1.(...........)

Site2.(.............)

Site3.(...........)

Site4.(...........)

E1Status

OK/

NOK

OK/

NOK

OK/

NOK

OK/

NOK

OK/

NOK

LinkXconnect

Site5.(...........)

Site6.(...........)

Site7.(...........)

Site8.(...........)

Site9.(...........)

E1Status

OK/

NOK

OK/

NOK

OK/

NOK

OK/

NOK

OK/

NOK

LinkXconnect

Site10.(...........)

Site11.(...........)

Site12.(...........)

Site13.(...........)

BSC
destination
(..............)

E1Status

OK/

NOK

OK/

NOK

OK/

NOK

OK/

NOK

OK/

NOK

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 12(43)

20SBY059_GRAHAFAMILY3

SEPARATEROOM

SEPARATEROOMNOTEXIST

DIMENSIONS:

mm(W)

mm(L)

mm(H)

Th

FLOOR:

LOCATIONSOFIDF,MDF,DDF:

IDF,MDF,DDFRACK

EXIST

NOTEXIST

NOTNEEDED

PCMCONNECTIONS

75(coax)

120balanced(PCM)..pair

NUMBEROFFREEPAIRS:

Pair,meters

SIGNAL/TRASMISSIONCABLES:

FROM

TO

CABLETYPE
GRAHAFAMILY3 BSC_CITRALAND RG214

LENGTH

NOTES

EXTERNALALARMS:

Omni(externalalarm)
Available

Yes/No
OnService
________Yes___________

Yes/No
___________________

DDFExternalalarmavailable

Yes/No
ConnectedtoOMNI

________Yes__________

Yes/No
___________________

ExistingalarmConnected(checkatDDForOMNI)
AlarmName

AlarmName

AlarmName

AlarmName

1.Dooropen

7.AVRautomaticbypass

13.Spare

19.

2.FiresmokeheatAlarm

8.outdoorunitAC

14.Loadfuse

20.

3.Gensetrun

9.Arresterfails

15.Batteryfusetrip

21.

4.Gensetfails

10.Spare

16.Rectifiermodulefails

22.

5.Temperature

11.ACpowerL1/L2/L3fails

17.

23.

6.Rectifiermainfails

12.Lowvoltagebattery

18.

24.

REMARKS:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 13(43)

20SBY059_GRAHAFAMILY3

2.10RadioTransmissionEquipment
Tickthebox(9),whenchecked.
DIRECTIONTOSITE
(nameofsite)

TYPE

FREQ.

CAPACITY

&Model

FEEDER
BASEBANDCABLE
TYPE

BSC_CITRALAND

NEC

7Ghz

15E1

Rg214

PERUMDRIYOREJO

NOKIA

13Ghz

8E1

RG214

RACK

REMARKS:

2.11.AntennaTower
Tickthebox(9),whenchecked.

TOWEREXIST:

YES

NO

TOBERENOVATED:

YES

NO

UNDERCONSTRUCTION:

YES

NO

PLANNEDDATEOFCOMPLETION:

(dd/mm/.yyyy)

LOCATIONANDDIRECTION:

SEESITEPLAN:

SEETOWERDRAWING:

PHOTOGRAPHS:

TYPE:
SST

POSISITION
GREENFIELD

POLE

ROOFTOP,Height:m

MONOPOLE

Others

Others:.

HEIGHTofTOWER

42

RESTANDWORKINGPLATFORMS/BORDES:

TYPE

HEIGHT

NOTES

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 14(43)

20SBY059_GRAHAFAMILY3

HORIZONTALLADDERFROMTOWERTOEQUIPMENTROOM/FEP

USEDEXISTING,width,400.mm,length,25000mm

PROPOSENEW

LENGTH:

mm

WIDTH:

mm

COVERED:

YES

NO

LENGTH:

VERTICALLADDER:
USEDEXISTING,width,400.mm,length,42000mm

PROPOSENEW
LENGTH:

mm

WIDTH:

mm

COVERED:

YES

NO

LENGTH:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 15(43)

20SBY059_GRAHAFAMILY3

Tickthebox(9),whenchecked

TOWERSTRUCTUREINFORMATION:

A
C

Pole/MonoPole
B

SST

Note:

A&B :TowerLegSize
C
:Pole/Monopolediameter

Tower Slope

LEG/SIDE

LEVEL(m)

D(deg)

(mm)

(mm)

(mm)

D=Tan (X/Y)

NOTE

42

150

150

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 16(43)

20SBY059_GRAHAFAMILY3

Tickthebox(9),whenchecked

ANTENNATOWERLEGLAYOUT,EXISTINGANDTHEIRTYPES,HEIGHTSANDDIRECTIONS:

ANTENNAMWandOthers:
LOCATION
LEG/SIDE

LEVEL
m

TYPE
No

Direction
(degree)

HEIGHT
mm

40

70

FREQUENCY NOTE
Mhz
(brand,andType)
900

40

240

900

40

310

900

35

80

35

180

35

280

Remarks:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 17(43)

20SBY059_GRAHAFAMILY3

Tickthebox(9),whenchecked

MHAEXISTING
LOCATION
LEG/SIDE

LEVEL
m

TYPE
No

HEIGHT
mm

FREQUENCY
NOTE
Mhz(Syetem:ie. (brand,andType)
GSM,DCS,CDMAetc)

FEEDEREXISTING
SECTOR

LENGTH
(m)

TYPE
(7/8or15/8)

Brand

Notes

52

7/8"

Draka

52

7/8"

Draka

52

7/8"

Draka

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 18(43)

20SBY059_GRAHAFAMILY3

ANTENNATOWERLEGLAYOUT,NEWANTENNASANDTHEIRTYPES,HEIGHTSANDDIRECTIONS:

BTSANTENNAS:

SECTOR
No

ANTENNA
purpose

DIRECTION
degrees

Tx/Rx

70

LOCATION LEVEL
legs/side
m

TYPE
No

HEIGHT
mm

AntennaTilt
(Electrical/
Mechanical):

NOTES

40

1300

6/4

Rxdiv.

70

40

1300

6/4

Tx/Rx

240

40

1300

6/5

Rxdiv.

240

40

1300

6/5

Tx/Rx

310

40

1300

6/5

Rxdiv.

40

310

1300

6/5

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 19(43)

20SBY059_GRAHAFAMILY3

MHAandFeederNEW
SECTOR
No

ANTENNA
purpose

LOCATION
legs/side

LEVEL
m

TYPE
No

HEIGHT
mm

Feeder
Feeder
Dim(7/8) Length(m)
or15/8)

Note
(combineor
NotCombine)

Tx/Rx

Rxdiv.

Tx/Rx

Rxdiv.

Tx/Rx

Rxdiv.

REMARKS:

2.12 Safety & Security


Check Point
1.
2.
3.
4.

OK

NOK

NA*

Towers aircraft warning light(s) (OBL-light) is installed & functioning properly


Lampu menara sebagai tanda peringatan untuk pesawat (lampu OBL) sudah terpasang dan bekerja

Access-ladder and handrails provided as needed and correct as per standard


Tangga dan pegangan tersedia sesuai dengan kebutuhan dan standar

The site area is free of construction waste and excess material


Area site bebas dari material sisa dan sampah hasil pembangunan

Safety equipment is available and correct as per standard


Peralatan keselamatan (contoh. pemadam api) memadai dan sesuai dengan standar

*NA = Not Applicable (dipilih jika item tidak digunakan untuk tipe site tertentu)
No

Number/Version: tssr.ver.7

Deficiency Items

Target of Completion

Person In Charge

Ketidaksesuaian

Target Penyelesaian

Penanggungjawab

Date: 11.04.2012

Check List Page 20(43)

20SBY059_GRAHAFAMILY3

SITESURVEYREPORT
3.1SITEPHOTOCHECK
DetailPhotoTakenNumber
i. SiteOverview:

ii. EquipmentLocationOverview:
iii. ExistingBTSEquipment:

iv. NewBTSEquipmentLocation:

v. ExistingACDistributionSystem:

vi. NewACDistributionSystemLocation:

vii. ExistingTransmissionEquipment:

viii. NewTransmissionEquipmentLocation:

ix. ExistingTransmissionDDF:

x. NewTransmissionDDFLocation:

xi. ExistingAlarmDDF:

xii. NewAlarmDDFLocation:

xiii. ExistingEquipmentPowerSystem:

xiv. NewEquipmentPowerSystemLocation:

xv. ExistingBatterySystem:

xvi. NewBatterySystemLocation:

xvii. ExistingAirConditioningSystem:

xviii. NewAirConditioningSystem:

xix. ExistingSiteCablingAndConnections:

xx. ExistingGroundingSystem:(Busbar,Connectionsetc.)

xxi. NewGroundingSystem:(Busbar,Connectionsetc.)

xxii. NewSiteCablingLocation:

xxiii. ExistingFeederRunAndCableWallThrough:

xxiv. NewFeederRunAndCableWallThrough:

xxv. ExistingAntennaLocation:

xxvi. NewAntennaLocation:

xxvii. NewLocationforshelter/shelterlessexpansion
xxviii. NewLocationforshelterless
xxix. Others:(Specify)

NOTE:PHOTOOFALLDAMAGESONEXISTINGCONSTRUCTIONSOREQUIPMENTSYSTEMHAVETOBETAKEN.IF
ANYCHANGESTOBEDONETOEXISTINGCONSTRUCTIONSOREQUIPMENTSYSTEM,PHOTOOFTHATHAVETO
BETAKENBEFOREANDAFTERCHANGES.

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 21(43)

20SBY059_GRAHAFAMILY3

SITE:GRAHAFAMILY3
SiteOverview

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 22(43)

20SBY059_GRAHAFAMILY3

SITE:GRAHAFAMILY3
EquipmentLocationOverview
Note:Maksimal2pictureperpage

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 23(43)

20SBY059_GRAHAFAMILY3

SITE:GRAHAFAMILY3
ExistingBTSEquipment

Note:Maksimal2pictureperpage

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 24(43)

20SBY059_GRAHAFAMILY3

N/A

SITE:GRAHAFAMILY3
NewBTSEquipmentLocation

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 25(43)

20SBY059_GRAHAFAMILY3

ACPDB

KWH

SITE:GRAHAFAMILY3
ExistingACDistributionSystem

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 26(43)

20SBY059_GRAHAFAMILY3

SITE:GRAHAFAMILY3
ExistingTransmissionEquipment

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 27(43)

20SBY059_GRAHAFAMILY3

SITE:GRAHAFAMILY3
ExistingTransmissionDDF

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 28(43)

20SBY059_GRAHAFAMILY3

N/A

SITE:GRAHAFAMILY3
NewTransmissionDDFLocation:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 29(43)

20SBY059_GRAHAFAMILY3

N/A

SITE:GRAHAFAMILY3
ExistingAlarmDDF:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 30(43)

20SBY059_GRAHAFAMILY3

N/A

SITE:GRAHAFAMILY3
NewAlarmDDFLocation

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 31(43)

20SBY059_GRAHAFAMILY3

SITE:GRAHAFAMILY3
ExistingEquipmentPowerSystem:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 32(43)

20SBY059_GRAHAFAMILY3

SITE:GRAHAFAMILY3
ExistingSiteCablingAndConnections:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 33(43)

20SBY059_GRAHAFAMILY3

SITE:GRAHAFAMILY3
ExistingGroundingSystem:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 34(43)

20SBY059_GRAHAFAMILY3

SITE:GRAHAFAMILY3
ExistingFeederRunAndCableWallThrough:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 35(43)

20SBY059_GRAHAFAMILY3

SITE:GRAHAFAMILY3
ExistingAntennaLocation:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 36(43)

20SBY059_GRAHAFAMILY3

DRAWING

Detail:

9 SiteLocation

9 SiteLayout

9 ProposeSiteLayoutforshelter/shleterlessexpansion(optionforconfig8/8/8)
9 ProposeSiteLayoutforNewShelterless(optionforconfig8/8/8)

9 TowerInformation,Antenna,andMountingProposed

9 EquipmentLayOut,Existing

9 EquipmentLayOut,Proposed

9 EquipmentLayOut,Proposedforflexiedge2stack(optionforconfig8/8/8)

9 EquipmentLayOut,ProposedforflexiedgeFCOA/19rack(optionforconfig8/8/8)
9 CableRouteDrawing,Indoor

9 CableTrayLayout,Existing

9 CableTayLayout,Proposed

Note:
1. ForTSSRcanuseA4paper
2. ForAsBuiltDrawingshoulduseA3paper
3. severaldrawingcanbedrawedattheonepage.

Number/Version: tssr.ver.7

Date: 11.04.2012

Page1
Page2
Page2A
Page2B
Page3
Page4
Page4
Page4A
Page4B
Page5
Page5
Page5

Check List Page 37(43)

20SBY059_GRAHAFAMILY3

4. TOWERSURVEYFORTISITES
5.3TowerHeight:42m

Towertype:IndosatLightdutytower.

Checkitems:

Description
Towerlegbottomsection
Diagonalbottomsection
Backtobackdistancebetweentowerlegsatbaselevel
DimensionofAnchorbolts
NumberofAnchorbolts
Latticeofbottomsectionasshownonbelowfigure

Latticetypefromdrawing

Valuefromdrawings
L130x130x12
L60x60x6
5000mm
25mm
8
Yes

Valueonsite
130x130x12
60x60x6
5000
25
8
Yes

Pictureshowinglatticeofbottomsectionoftower

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 38(43)

20SBY059_GRAHAFAMILY3

RF SITE FORM
Physical RF Information

Ver 4

General Description

Audit Consecutive Number


Region
City / Town / Village / Area
Site Latitude
Site Longitude
Site Address
Survey Date
Band or Technology
GSM 900 MHz

WCDMA 2100 MHz

GSM 1800 MHz

CDMA 800 MHz

Other

Site ID
Site Name
Vendor
Project Name
Program Name

Site Type
Roof Top (Antenas on wall)

Roof Top (Antenas on poles)

Green field Monopole

Green Field Tower

Roof Top (Antenas on monopo

Other

Shelterless

Found Configuration

Sector (Add more columns if required)


Pole/Tower Height
Tower Ownership
BTS Location (Inside/ Outside Shelter)
Type of BTS / Node B
Antenna Height (Above Ground)
Antenna Support (Y/N)
Type of Antenna (Model)
Antenna Serial Number
Number of Antennas
Antenna Azimuth
Antenna Mechanical Tilt
Type of Electrical Tilt (fixed/adjustable/RET)
Antenna Electrical Tilt
Feeder Brand
Type of Feeder (diameter)
Number of Feeder Line per Sector
Length of Feeder
Type of Combiner
Number of Combiners
Type of Diplexer / Triplexer
Number of Diplexer / Triplexer
Type of TMA / Pnom / Inline Repeater
MCPA (No/20/40/60 W)
Type of Filter
Type of RRU
Number of RRUs
RRU Location
(Near Antenna (Height) / Bottom of Tower building)
Number of TRX / Carriers / CEs (Hardware)
Number of TRX / Carriers / CEs (Software)
Digital Unit / System Module / BBU Type
Number of Digital Unit / System Module / BBU Type

Data Requested by
Radio Planning

Quality Improvement

Optimization

O&M

Project Team

Regional

Requested by (Name)

Comments

RF Information collected by
Company

Dept. / Area

Person (Complete Name)


Signature

Updated in NDB by
Updated in NDB

by

Date

Updated in Planning Tool


Updated in Asset 3G

Number/Version: tssr.ver.7

by

Date

Date

Approved by
Date: 11.04.2012

Check List Page 39(43)

20SBY059_GRAHAFAMILY3

MW SITE FORM
Physical MW Information

General Description

Audit Consecutive Number

Site ID

Region

Site Name

City / Town / Village / Area

NE ID

Site Latitude

Vendor

Site Longitude

Project Name

Site Address
Form Filling Date
Technology
TDM Radio

IP Radio

IP Hybrid Radio

SDH Radio

Site Type
Roof Top (Antenas on wall)

Other

Roof Top (Antenas on poles)

Green field Monopole

Green Field Tower

Roof Top (Antenas on monopo

Other

Shelterless

Found Configuration

Site (Add more columns if required)

Near End

Far End

Tower Height (m)


Antenna Height (m)
Altitude (m.a.s.l)
Antenna Azimuth
Antenna Type
Antenna Gain (dB)
Antenna Diameter (m)
Feeder Type
Feeder Length (m)
Radio Model
Equipment Capacity
Hardware Capacity
Software Capacity
Modulation Type
Frequency Band (GHz)
Sub Band (MHz)
Transmitter Frequency (MHz)
Frequency Channel
Protection Configuration
Rx Level (dBm)
Sensitivity Threshold (dBm)
Polarization
Data Requested by
Transmission Planning

Quality Improvement

Optimization

O&M

Regional

Requested by (Name)

Project Team

Comments

Data performed by
Company

Dept. / Area

Person (Complete Name)


Signature

Updated in NDB
Updated in NDB

by

Updated in Planning Tool


Updated in Connect Planning Tool

by

Number/Version: tssr.ver.7

Date

Date: 11.04.2012
Approved by
Date

Check List Page 40(43)

20SBY059_GRAHAFAMILY3

BillofQuantityMiniCME

TypeofWork/Jenispekerjaan

:Mordernization(Indoor&Outdoor)

Project/Proyek

:BufferStock2(EJBN)

Location/Lokasi

:GRAHAFAMILY3

SiteID/SiteID

:20SBY059

Green Field (CME)

Rooftop (CME)

Existing Modification (CME)

OTHER (CME)

CME Description

EA

Shelterless 1 Rak FLEXI BTS Only

lot

Shelterless 2 Rak Multi BTS

lot

Shelterless 2 Rak FLEXI BTS Only

lot

Shelterless 4 Rak Multi BTS

lot

Shelterless 4 Rak FLEXI BTS Only

lot

Pole FMR

lot

Hammer Test & Structural Design

lot

Base frame beton 20/30 Roff top

Pole 3 m

set

Pole 6 m

set

Pole 9 m

set

Pole 12 m

set

POLE FMR Rooftop

set

CKD Modifikasi Type 1 ( 2 Unit AC )

lot

CKD Modifikasi Type 2 ( 3 Unit AC )

lot

OD Vertical Cable Tray, W 40cm

OD Horizontal Cable Tray, W 40cm

Indoor Cable Tray W=40 cm, (Indoor CKD)

Grounding cable, Al tape 3x25mm

Al Busbar, 300x100x10mm

pcs

MCB 80A phase 1

pcs

MCB 100A phase 1

pcs

FEP 8 Holes

pcs

FEP 12 Holes

pcs

Feeder Shifting

lot

Rearranging of existing feeder

lot

AC 1.5 PK

set

AC 2PK

set

Removal Air Conditioner

set

PARTNERTI:

PT.NOKIASIEMENSNETWORKS

PT.INDOSAT

Name/Nama:
Date/Tanggal:

Name/Nama:
Date/Tanggal:

Name/Nama:
Date/Tanggal:

Number/Version: tssr.ver.7

Date: 11.04.2012

QTY

Check List Page 41(43)

20SBY059_GRAHAFAMILY3

ONSITEAGREEMENTCERTIFICATE/BeritaAcaraKesepakatanLapangan

TypeofWork/Jenispekerjaan
Project/Proyek
Location/Lokasi
SiteID/SiteID

:
:
:
:

Mordenization(Indoor&Outdoor)
BufferStock2
GRAHAFAMILY3
20SBY059

AccordingbySiteSurveyatSiteLocation,wecanexplaintheresult:
BerdasarkanHasilSurveydiLokasi,DapatKamiUraikanSebagaiBerikut:

1.BTSInstallationPlan/RencanaPemasanganBTS
ItwillinstallBTSGSMFMRwithconfig324.
Dismantleexistingfeeder,1set
DualDuplexedOutdoorFilter,3pcs
2.AntennaandFeederInstallationPlan/RencanaPemasanganAntennadanFeederCable
itwillinstall3AntennaArgusCVVPX308.10R6Pat3sectorwithheight40m
3. MainPowerSupplySystemInstallationPlan/RencanaPemasanganCatuDaya
useexistingRectifier
4.TransmissionSystemInstallationPlan/RencanaPemasanganSistemTransmisi

usingexistingtransmission
5.CMEWorkPackagePlan/RencanaPackageCMEyangdiperlukan
CivilWorkPackage/PaketPekerjaanCivil
Mechanical&ElectricalWork/PaketPekerjaanMekanikal&Elektrikal
6.Commentsthathelpwiththesiteplan/Keteranganlainyangmembantupembangunansite

AlBusbar,300x100x10mm,1pcs
Acknowledgement:

SiteREADYforTIimplementation
SiteSUDAHsiapuntukTIImplementation

SiteNOTreadyforTIimplementation
SiteBELUMsiapuntukTIImplementation

PARTNERTI:

PT.NOKIASIEMENSNETWORKS

PT.INDOSAT

Name/Nama:
Date/Tanggal:

Name/Nama:
Date/Tanggal:

Name/Nama:
Date/Tanggal:

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 42(43)

20SBY059_GRAHAFAMILY3

Change Note History:


Version
5

5.1

5.2

5.3

5.4

5.5

6.1

7.5

ChangeNote

FirstRelease

Changeformatontowerstructureinformation,adddetailontowerslopecalculation.
Addtemplateforpicture
ChangeHeaderontopright,formSurveyChecklisttoSiteID_SiteName
Additemfordrawing(mounting&cabletraylayout)
AddACPowermeasurementeachphase,ACPDBinformation
Addinformationonbatteryandrectifier
Deletebatteryroominformation
AddSiteinformationaboutsiteaccesskey,listofsurveyor,
Addbuildinginformationonaccesstoroof
Addonequipmentroominformation
EditonFEPtype,
Additemongroundingsysteminformation
EditandAddinformationonCableladderinformation
Add Column direction antenna on antenna tower leg layout, existing and their types, heights and
directions
AdditemonOnSiteAgreement
Deletedrawingpage
Add5pageadditionalsurveyforTowerStructureInformation
AddphotoNewLocationforshelter/shleterlessexpansion
AddphotoNewLocationforshleterless.
AddDrawingEquipmentLayOutproposed
AddDrawingEquipmentLayOut,Proposedforflexiedge2stack(optionforconfig8/8/8)
AddDrawingEquipmentLayOut,ProposedforflexiedgeFCOA/19rack(optionforconfig8/8/8)
ReviseONSITEAGREEMENT

ReviseEquipmentRoom
DeleteCableTrayatpoint1.6
ChangeMCBCapacityatRectifier
AddRectifierCapacityfornewBTS
AddBattaerycapacityfornewBTS
RevisionandAddGroundingEquipmenttype
ModificationTransmissionDDF
ReviseONSITEAGREEMENT
Addvisualchecklistcivilwork
AddMEWorkCheck
AddSafety%Securitychecklist
AddIndosatsiteauditform
Addsitecontractinformation
AddACPowerstability
ModificationRoomtemperatureforAirConditioner
AddoptionforBTSFMRtype&BS24xtype(insitetype&equipmentroom)
Addlinkxconnection
AddAcknowledgementforTIimplementationprogressinOSAG
AddRFandMWSiteform
AddBoQminiCME

Number/Version: tssr.ver.7

Date: 11.04.2012

Check List Page 43(43)