You are on page 1of 1

represented by:

measurIT technologies

Measuring Task Flow measurement


Measurement of the flow rate in the dam ground tunnel between upper in a dam tunnel
and lower reservoir at a DN 600 pipe

Instruments Used Customer


2-channel FLUXUS ADM 7807 with transducers M2N
Advantages
• small dimensions of the transducers – they can be carried where
you can go
• cost saving transportation to the final location – no crane necessary
• good valued instrument
• insensitive against layers in the pipes The Wasserverband Eifel-Ruhr
• maintenance free, no moving parts (W V E R) is a body of public law
and operates six dams in “Nord-
• no process interruption eifel” region.

Description
To ensure long term security for the “Urfttalsperre” dam, construction
works on the ground tunnel in the years 1994 to 2000 have been exe-
cuted. Among other measurements the flow measurement of the lead
over from the 60 m higher Urft-lake in the lower lake has been erected.
The problem was the realisation of the measurement in the deep tunnel
of the dam between the two lakes.
At first the planners thought about magmeters to solve the problem. Ex-
tensive construction works would have been necessary for only moving Urft dam
the magmeters to their final destination in the ground tunnel. Due to tre-
mendous cost for such adaptations the engineers looked for an alterna-
tive and found the FLUXUS ADM ultrasonic flowmeter from FLEXIM.
The small transducers and the electronics could easily be brought to their
final destination in the dam. Without cutting of the pipework, weldings and
shut down of the line the instrument was set into operation within less
then half a day. It covers a huge dynamic range from some millimetres
per second flow velocity up to some meters. The measurement is used to
record the water quantity and protect the system against to high flow
velocities and the ring pipe against burst. After final tests under all possi-
ble flow conditions that can occur during operation the instrument was
approved as safe and stable.

cross section of the dam

FLUXUS®, WaveInjector®; and PIOX® are protected trademarks of FLEXIM GmbH. Copying and distribution allowed only with the written permission of
FLEXIM GmbH. The copyright of this report, its components, content and pictures is owned by FLEXIM or by third parties. All rights reserved. The aim of
this application report is solely to give general information about the application. It does not assure the suitability of the instrument for a specific purpose.
AR-200005-WVER-EN.doc, 02/10/00, Page 1 of 1

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963

You might also like