You are on page 1of 4

All it takes to operate.

AESCULAP AG & CO. KG


Am Aesculap-Platz
78532 Tuttlingen
All rights reserved. Technical alterations are possible. This leaflet may be used for no
other purposes than offering, buying and selling of our products. No part may be
copied or reproduced in any form. In the case of misuse we retain the rights to recall
our catalogues and pricelists and to take legal actions.

Brochure Nr. BBSE-018-02

Phone +49 7461 95-0


Fax +49 7461 95-2600
www.aesculap.de
0704/1/3

B. Braun Sutures
Ventrofil
For tension relief

Suture set with twisted stainless steel thread and a polyethylene


cover

Ventrofil
For tension relief
The rupture of an abdominal wound is still regarded as a serious life-threatening complication. Its frequency is
given in the literature as 1-3%, its mortality rate as 15-20%.
The healing of a wound can be interrupted by a number of factors, most of them have their origin in the general
situation of the patient. Possible factors are elderly patients, chronical respiratory illness, or metabolic disorders.
The only possibility to prevent such a complication is the primary use of a tension relief suture set.
Ventrofil is a Special Suture Set for the treatment and prevention of abdominal ruptures after laparotomy or
other wound dehiscence and for the relief of strain on existing wounds.

Use of Ventrofil

Indications
Probable woundhealing disturbances
Emergency laparotomies
Re-laparotomies
Peritonitis/ileus
Elderly patients
Broncho-pulmonary infections
Operations of carcinoma
Long lasting operations
Coagulation abnormalities

The suture is placed as far as possible from the operating wound, and it should
not include the peritoneum.
The suture should traverse the abdominal wall approximately tangentially and
preperitoneally.
The fascial sutures are adapted only loosely.
The suture is placed through the slits of the plates.
The U-shaped sutures are fixed with measured tension by four or five counter
hitches.
Under normal conditions, i.e. with undisturbed woundhealing, the Ventrofil
is removed after about 2 weeks.

stainless steel
non-absorbable
polyethylene cover
twisted

Advantages
The coated wire cannot cut in the tissues
and glides smoothly through it
Particles or moisture cannot penetrate
the padded plates
Less pressure on the skin, no pressure
necroses
Variation possibilities because of some
holes
Great flexibility of the polyfil coated wire
Easy fixation of the wire
Product Range
Polyfil steel

Length

Diameter

Accessories

Units / box

Cat. Nr.

75 cm

1.3 mm

2
polyethylene
plates

99 3042

90 cm

1.3 mm

2
polyethylene
plates

99 3034

2xDS 100

Product features
Composition

Stainless steel

Structure

Twisted

Coating

Polyethylene cover

Color

Metallic

Sizes

1,3 mm

Mass absorption

Non-absorbable

Indications

Tension relief

Contra-indications

Not known

Sterilisation

Gamma radiation