Residential & Light


Commercial HVAC
2016 LG Canada Engineering and Specifications Guide
Version 2016

www.LGcomfort.ca

Research &
Development
LG Research & Development Center
LG Electronics possess over 30 R&D centers around the globe in countries
including Korea, United States, China, Russia, Germany, Israel, Japan,
France, India, etc.
Each research center is focused on procuring technology unique to LG, as well as
strengthening core competitiveness applicable in all areas of business and developing the
engine for future growth.

LG AC Academy
Our Toronto LG AC Academy is an invaluable technical training and
technical support resource. Please contact HVAC Technical Support
at 866-543-8324 for course information.

Awards
LG air conditioners have been recognized in both outstanding performance
and stylish design by diverse world renowned organizations in the form of
having received many different prestigious awards.

Table of Contents
2.

Research & Development

3.

LG AC Academy

6.

Accessories & Control Options

8.

Showroom Displays

9.

Low Ambient Cooling

10. The LG Advantage

All blue links are functional


throughout this catalogue.

11. Easy Installation


12. Model Lineup
Multi F & Multi F MAX
14. Multi F Whole-House Solutions
16. Multi F Combination Chart
17. Multi F Outdoor
19. Multi F MAX Outdoor
21. Multi F Vertical Air Handler LMVN
22. Multi F Horizontal Air Handler LMHN
23. Multi F Gloss White LSN Universal Indoor / LMN
25. Multi F Art Cool Mirror LMAN
26. Multi F Art Cool Gallery LMAN
27. Multi F Ceiling Cassette LMCN
28. Multi F Low-Static Air Handler LMDN
29. Multi F & Multi F MAX Efficiency / Capacity Table
Single Zone
30. Art Cool Prestige
33. Art Cool Mirror Universal Indoor / Outdoor Unit
35. Gloss White Universal Indoor / Outdoor Unit
38. Gloss White 115V Mega
39. Gloss White Long Lineset Commercial Unit
40. Ceiling Cassette
42. High-Static Horizontal Air Handler
44. PTAC

NOTES

Accessories & Control Options


For central controllers, BAS, BACNet, etc. call LG Tech Support at (866) 543-8324.

PREMTA000 Deluxe Colour Touch-Screen Controller

Large, full-colour touch screen


Programmable Wired Controller Applicable to all current LG models
Ships with 33 cable
Features screw terminals for field-wiring option

PREMTB10U Wired Programmable Controller

Programmable Wired Controller Applicable to all current LG models


Ships with 33 cable
Features screw terminals for field-wiring option

LG Smart AC Wi-Fi Module PCRCUDT3 for Android & iOS phones


Compatible indoor models:
Art Cool Prestige LAN models
Single Zone Gloss White LSN090HSV4, LSN120HSV4, LSN180HSV4
(Indoor units with 2015 December and 2016 serial numbers will function
with Multi F outdoor units)
Gloss White Multi F LMN078HVT
Gloss White LSN240HSV3, LSN307HV3, LSN360HV3
App is free. Download at
or

SIMS Diagnostic Module PSWMOZ3 (All inverters except Multi F MAX)


Mobile LGMV PLGMVW100 (For Multi F MAX LMU480HV, LMU540HV,
LMU600HV)
View and diagnose compressor & fan speed, thermistor temperatures, etc.
Operates with Android and iOS
App is free. Download at
or

PZCWRCG3 Group Control / Extension Wire

For group control (requires PREMTB10U wired controller)


of up to 8 Multi F or 4 Single-Zone indoor units
For use as a 33 extension cable when required
One fewer wire is required than number of group controlled units
(Eg. 5 units require 4 wires)

Accessories & Control Options


For central controllers, BAS, BACNet, etc. call LG Tech Support at (866) 543-8324.

PRARH0, PRARS0 & PRARS1 Auxiliary Heat Relays


PRARH0: Air handlers & ceiling cassettes
PRARS0: Wall-mounted model numbers beginning LS
PRARS1: Wall-mounted model numbers beginning LM

(Auxiliary heat relays require a PREMT**** wired controller to operate)

3rd Party Thermostat Kit PDRYCB300

Compatible with all current models


Requires 24V AC transformer
Plugs into indoor circuit board and includes 30 harness

Base Pan Heaters PQSH1201 & PQSH1200

PQSH1201 applies to LSU180HSV4


PQSH1200 applies to LMU18CHV, LMU24CHV, LMU30CHV,
LMU36CHV, LMU480HV, LMU540HV & LMU600HV

Mockup In-Home Sales Demo Units


ARTRACKPIC Display Stand
Display
Stand
(model # ARTRACKPIC)

Art Cool Mirror


Non-Functional
Display Unit

Art Cool Prestige


Non-Functional
Display Unit
(model # ASMW123MMB9)

(model # ASMW09GBRU2)

Gloss White
Non-Functional
Display Unit
(model # ASMW09GB1U2)

Disclaimer: Items represented in this catalogue may change without notice. LG is not responsible for information contained in this catalogue that may have changed.
Please contact your LG Sales Representative for updated information.

Low Ambient Cooling


All LG systems listed in this catalogue can be easily configured for low ambient cooling. The low ambient kit will
not enhance or detract from heating mode performance.
By utilizing the wind guards and control adapters shown below, preparation for low ambient operation is fast
and easy. Most units can be set up in under thirty minutes.
Low ambient kit information is now on each models specification page.
Please visit http://LGcomfort.ca/en/technical-support-technical-support.aspx for the low ambient kit installation manual.

Low Ambient Kit Compatibility


PQCA0
PAG-HS0
PAG-HS1
PAG-HS2
PAG-HS3
PAG-HS4
PAG-HS5
PAG-HS6
PAG-HS7
PAG-HS8

Control adapter for all models


Front wind guard for 9k models & LSU120HSV4, LMU18CHV, LMU24CHV
Rear/side wind guard for LMU18CHV & LMU24CHV
rear / side wind guard single fan models 18 - 36k excluding LUU or LMU models
rear / side wind guard for 9 & 12k models
rear / side wind guard for LMU480HV, LMU540HV, LMU600HV, LUU367HV, LUU427HV
front wind guard for LMU480HV, LMU540HV, LMU600HV, LUU367HV, LUU427HV
front wind guard for LMU30CHV, LMU36CHV, LUU187HV, LUU247HV
rear/side wind guard for LMU30CHV, LMU36CHV, LUU187HV, LUU247HV
front wind guard for single fan models 18 - 36k excluding LUU or LMU models

Feature Advantages:

The LG Advantage
Take advantage of our smart solutions
for residential & commercial air
conditioning applications.
LG HVAC systems offer a range of solutions that are
cost efficient, quiet and attractive. They provide a
smart alternative to both central HVAC and windowmounted air conditioners, and are available in a variety
of configurations to suit different cooling and heating
situations.

SPLIT SYSTEMS
These innovative systems are split into indoor and
outdoor units. The interior units are available in
several different configurations: Art Cool, standard
wall-mounted, and ceiling cassettes. All interior units
have remote controls for easy use. Installation by a
qualified HVAC contractor is safe and easy no duct
work or sheet metal is required. Multi zone systems are
also available.

PTAC MODELS
LGs new PTAC units are perfect for lodging and
healthcare applications. These units have a low
decibel level and outstanding sound prevention
rating.

Look for these key features throughout the LG line.

Inverter systems have variable-speed compressors rather than the fixedspeed compressors of traditional systems. Rather than running at full
capacity then shutting down, an inverter system ramps the compressor
speed up or down to match the requirement of the space. Inverter
systems have quieter operation, provide greater comfort and use less
energy than conventional on/off systems.

Self-Cleaning Indoor Coil

Drives dirt and moisture from coil surface leaving it clean.

Dehumidifying Mode

Running at the lowest airflow and air conditioning capacity, humidity is


removed from the space while not over-cooling.

Chaos Wind

Electronically controlled fan speeds create a more natural, random flow


of air, reducing temperature stratification.

Jet Cool

Operates at high speed for up to 30 minutes to quickly cool a room


down to 64 F.

Swirl Wind

4-Way controlled louvers and fan speeds create a stronger, wider air
flow and reduce temperature stratification.

Auto Operation

Provides three levels of comfort from which to choose. Temperature and fan
speed will set automatically.

Manual Power Switch

Easily accessed button allows for continued operation if the remote


control is misplaced.

Defrost Control

HIGH-STATIC AIR HANDLERS


Introduced in late 2013, LG now offers 2 & 3 ton
vertical / horizontal high-static air handlers with
auxiliary heaters for the Multi F and Multi F MAX
product.
We additionally offer single zone and Multi F 2 & 3
ton high static horizontal-only air handlers.

Shuts down the indoor fan to prevent cold air from being blown
into the zone. Removes frost from outdoor coil when the outdoor
temperature is low.

Sleep Mode

Automatically increases the temperature setting 2 F twice (after 1/2 hour


and one hour). The interior unit shuts off when the timer setting is reached.

Auto Restart

Automatically restarts a unit to programmed setting when the


electricity comes on
after a power failure.

Gold Fin

All outdoor unit coils have a corrosion resistant GoldFin coating


standard from the factory. GoldFin will promote sustainable efficiency
and coil life by helping to prevent corrosion caused by everyday
pollutants.

NOTE: All features are not available on all models. See product spec sheet for details.

10

Easy
Installation
All LG inverter indoor units feature a removable bottom panel and swing-out wall stand
for easy installation. All refrigeration, condensate drain and electrical connections are in
plain sight during installation.

Wider Tubing Space


More room for piping and wiring makes for
a cleaner, faster installation

Conventional

100%

Detachable Bottom Cover


By removing the bottom cover, the
refrigeration and condensate
connections are all in
plain sight for faster,
easier installation.

LG

145%

The tubing space is 45% wider than those of the


previous air conditioners for easier installations

Installation Plate Improvement


LGs installation plate is wider and
modified to reduce installation time.

Disassembly or additional supporting of the unit is


unneccessary due to the detachable chassis bottom and
supporter
With LGs patented supporter, installation can be
completed by one individual.

Pipe Clamp / Wall Stand


The pipe clamp swings out as a wall stand
to make installation far easier.

The instruction tip engraved in the plate also assists


easy installation by not having to go through the
install manual

25

6"

11

Model Line-Up

Single Zone

Art Cool
Prestige

Art Cool
115V Mega

Art Cool Mirror

Gloss White

9,000

LAU090HYV1 /
LAN090HYV1

LSU090HXV /
LSN090HXV

LSU090HSV4* /
LAN090HSV4

LSU090HSV4* /
LSN090HSV4

12,000

LAU120HYV /
LAN120HYV

LSU120HXV /
LSN120HXV

LSU120HSV4* /
LAN120HSV4

LSU120HSV4* /
LSN120HSV4

18,000

LAU180HYV1 /
LAN180HYV1

LSU180HSV4* /
LAN180HSV4

LSU180HSV4* /
LSN180HSV4

LAU240HYV1 /
LAN240HYV1

LAU240HSV2 /
LAN240HSV2

24,000

Gloss White

LSU240HSV3 /
LSN240HSV3
LSU240HLV /
LSN240HLV
LSU307HV3 /
LSN307HV3
LSU300HLV /
LSN300HLV
LSU360HV3 /
LSN360HV3
LSU360HLV /
LSN360HLV

30,000

36,000

42,000

Multi F

7,000

LMN078HVT

9,000

LAN090HSV4**

LSN090HSV4***

12,000

LAN120HSV4**

LSN120HSV4***

15,000
18,000

LMN158HVT
LAN180HSV4**

LSN180HSV4***

24,000

LMN248HVT

36,000
42,000

* LSU090HSV4, LSU120HSV4 & LSU180HSV4 are universal outdoor unit


for their respective Gloss White and Art Cool Mirror indoor units.
** LAN090HSV4, LAN120HSV4 & LAN180HSV4 are universal indoor units for Single Zone & Multi F
*** LSN090HSV4, LSN120HSV4 & LSN180HSV4 are universal indoor units for Single Zone & Multi F
12

Art Cool Gallery

High Static
Horizontal Air
Handler

High Static Vertical


/Horizontal Air
Handler

Low Static
Horizontal Air
Handler

Ceiling Cassette

Single Zone

9,000
12,000
18,000

LUU187HV /
LCN187HV

24,000

LUU247HV /
LHN247HV

LUU247HV /
LCN247HV

LUU367HV /
LHN367HV

LUU367HV /
LCN367HV

30,000
36,000
42,000

LUU427HV /
LCN427HV

Multi F

7,000
9,000

LMAN097HVP

LMDN096HV

LMCN097HV

12,000

LMAN127HVP

LMDN126HV

LMCN125HV

LMDN186HV

LMCN185HV

15,000
18,000
24,000

LMHN240HV

LMVN240HV

36,000

LMHN360HV

LMVN360HV

42,000

13

Multi F Whole-House Solutions


Multi F multiple piping models (all linesets connect directly to the outdoor unit) can support two, three or four indoor units. Mix and match indoor
unit styles as you need with the combinations shown on Page 16.

Multi F CHV models detailed in this book are backwards compatible


with all existing inverter Multi F product.
Features

Published heating capacities down to -20C on all models


Continual operation below this temperature
New 2 1/2 ton model for 2015
Maximum flexibility - connect 135% of indoor units relative to outdoor unit capacity
Self diagnosis
Soft start
Inverter (Variable speed compressor)
Out-of-the-box low ambient cooling mode operation to -10C
Gold Fin anti-corrosion coil
Outdoor unit includes sufficient refrigerant for charging 2, 3, or 4 indoor units using 25 feet of pipe to each (dependent upon model)

Benefits

Long refrigerant piping lengths allow for extra design flexibility in indoor unit placement
Indoor unit and outdoor unit dimensions ensure space saving convenience
All-season useheat pump models have both cooling and heating capabilities

LMU18CHV
2-Zone Multi F Heat Pump Inverter System
Mix and match for 9,000-24,000 BTU/h.

14

LMU24CHV
2-3 Zone Multi F Heat Pump Inverter System
Mix and match for 12,000-33,000 BTU/h.

LMU30CHV & LMU36CHV


2-4 Zone Quad-Zone Multi F Heat Pump Inverter System
Mix and match for 18,000-48,000 BTU/h.

Multi F MAX
4 ~ 4 1/2 ~ 5 Ton
Multi F MAX distributor box models (all linesets connect to distributor boxes containing electronic expansion valves) can support up to eight indoor
units. Mix and match indoor unit styles as you need with the combinations shown on Page 16.

LMU480HV, LMU540HV & LMU600HV are backwards compatible with all existing inverter Multi F product.
Features

Published heating capacities down to -20C on both models


Continual operation below this temperature
4 ton model added in 2015 and a new 5 ton model is available for 2016
Maximum flexibility - connect 135% of indoor units relative to outdoor unit capacity
Self diagnosis
Soft start
Inverter (Variable speed compressor)
Out-of-the-box low ambient cooling mode operation to -10C
Gold Fin anti-corrosion coil

Benefits

Long refrigerant piping lengths - up to 475 total feet - allow for extra design flexibility in indoor unit placement
Indoor unit and outdoor unit dimensions ensure space saving convenience
All-season useheat pump models have both cooling and heating capabilities

LMU480HV & LMU540HV & LMU600HV


2-8 Zone Multi F MAX Heat Pump Inverter System
Mix and match for 24,000-81,000 Btu/h.

15

Multi F Outdoor Unit


Combination Chart
This chart defines which indoor units can be matched with which outdoor units. For complete indoor / outdoor
capacity and combination charts, visit http://www.LGcomfort.ca/en/multi-f-outdoor-units.aspx

Outdoor Units
LMU18CHV

LMU24CHV

LMU30CHV

LMU36CHV

LMU480HV

LMU540HV

LMU600HV

Maximum number of connectible indoor units / Maximum combined BTU capacity of indoor units


Gloss White

Art Cool
Mirror

Art Cool
Gallery

Ceiling Cassette

Low-Static Air
Handler

Horizontal Air
Handler
Vertical Air
Handler

Distributor
Box

16

Model

Btu/h Class

2 / 24,000

3 / 33,000

4 / 40,000

4 / 48,000

8 / 65,000

8 / 73,000

8 / 81,000

LMN078HVT

7,000

LSN090HSV4

9,000

LSN120HSV4

12,000

LMN158HVT

15,000

LSN180HSV4

18,000

LMN248HVT

24,000

LAN090HSV4

9,000

LAN120HSV4

12,000

LAN180HSV4

18,000

LMAN097HVP

9,000

LMAN127HVP

12,000

LMCN097HV

9,000

LMCN125HV

12,000

LMCN185HV

18,000

LMDN096HV

9,000

LMDN126HV

12,000

LMDN186HV

18,000

LMHN240HV

24,000

LMHN360HV

36,000

LMVN240HV

24,000

LMVN360HV

36,000

PMBD3620

up to 24,000

PMBD3630

up to 24,000

PMBD3640

up to 24,000

PMBD3641

up to 36,000

Multi F Outdoor

Multi F

-20C operation
18,000 - 24,000 BTU
LMU18CHV
18,000 BTU Class
2 Indoor Units

Outdoor Model Number


Energy Star

LMU24CHV
24,000 BTU Class
2 - 3 Indoor Units
Non-ducted indoor
Mixed ducted & non-ducted indoor

Non-ducted indoor
Connectable Indoor Units
Maximum Sum Of Indoor Units
Capacities And Efficiencies Shown By Maximum Connectable Indoor Units
Cooling Capacity, Non-Ducted Indoor1 (BTU/hr)
Heating Capacity, Non-Ducted Indoor1 (BTU/hr)
E.E.R.1
S.E.E.R.1
C.O.P.1
H.S.P.F (Region IV / V)
Power Supply ( / V / Hz)
MCA / MOP
Connecting Wire Outdoor To Indoor2:
Dimension W x H x D (Inch)
Net Weight (Lbs)
Operation Range
Sound Pressure (dBA) Cooling / Heating
Minimum ~ Maximum Lineset Length (Ft)
Maximum Total Lineset Combined Length (Ft)
Maximum Lineset Elevation Outdoor - Indoor (Ft)
Maximum Vertical Separation Indoor - Indoor (Ft)
Liquid Line Connection and Quantity (Inch)
Gas Line Connection and Quantity (Inch)
Refrigerant
Factory Charge for Combined Lineset Length (Ft)
Factory Charge (Oz)
Charge Adjustment Over Precharge Length (Oz / Ft)
Compressor Number and Type

2
24,000

10,200 ~ 17,000 ~ 19,000


13,200 ~ 22,000 ~ 24,000
13
22
3.2
9.7 / 8.43
1 / 208 ~ 230 / 60
13.3 / 20
4 x minimum 16# (ground included) stranded,
rated at 300V minimum
34 1/4 25 25/32 12 19/32
99.2
Cooling (DB) -20 ~ 48C (-4 ~ 118F)
Heating (WB) -20 ~ 18C (-4 ~ 64F)
49 / 52
10 ~ 82
164
50
25
1/4 x 2
3/8 x 2
R410A
50 feet
63.5
.22
1 Twin Rotary Inverter

2-3
33,000
12,000 ~ 20,000 ~ 25,000
14,400 ~ 24,000 ~ 28,800
13.5
21.7
3.9
10.6 / 9.22
1 / 208 ~ 230 / 60
14.3 / 20
4 x minimum 16# (ground included) stranded,
rated at 300V minimum
34 1/4 25 25/32 12 19/32
99.2
-20 ~ 48C (-4 ~ 118F)
-20 ~ 18C (-4 ~ 64F)
49 / 52
10 ~ 82
246
50
25
1/4 x 3
3/8 x 3
R410A
75 feet
63.5
.22
1 Twin Rotary Inverter

Warranty: 5 years parts, 7 years compressor


Optional Accessories:
PQSH1200 Base Pan Heater
Contact LG Technical Support regarding Dry Contact options for external control at 866-543-8324
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

PAG-HS0
PAG-HS1
PQCA0

PAG-HS0
PAG-HS1
PQCA0

Note: LMU18CHV, LMU24CHV, LMU30CHV & LMU36CHV are never matched with a distributor box.
LMU480HV, LMU540HV & LMU600HV always require at least one distributor box.

Non-ducted ratings and capacities are shown with maximum indoor units connected. For Ducted or Mixed Ducted and Non-Ducted combinations,
refer to Engineering Manuals containing capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx

Rated capacities are based on the following conditions:


Cooling: - Indoor Temperature 26.7C (80F) DB / 19.4C (67F) WB
- Outdoor Temperature 35C (95F) DB / 23.9C (75F) WB
Heating: - Indoor Temperature 21.1C (70F) DB / 15.6C (60F) WB
All electrical wiring must comply with applicable local, provincial and national codes.

17

Multi F Outdoor

Multi F

-20C operation
30,000 - 36,000 BTU
LMU30CHV
30,000 BTU Class
2 - 4 Indoor Units

Outdoor Model Number


Energy Star

Non-ducted indoor
Mixed ducted & non-ducted indoor

Maximum Sum Of Indoor Units


Capacities And Efficiencies Shown By Maximum Connectable Indoor Units
Cooling Capacity, Non-Ducted Indoor1 (BTU/hr)
Heating Capacity, Non-Ducted Indoor1 (BTU/hr)
E.E.R.1
S.E.E.R.1
C.O.P.1
H.S.P.F (Region IV / V)
Power Supply ( / V / Hz)
MCA / MOP
Connecting Wire Outdoor To Indoor2:
Dimension W x H x D (Inch)
Net Weight (Lbs)
Operation Range
Sound Pressure (dBA) Cooling / Heating
Minimum ~ Maximum Lineset Length (Ft)
Maximum Total Lineset Combined Length (Ft)
Maximum Lineset Elevation Outdoor - Indoor (Ft)
Maximum Vertical Separation Indoor - Indoor (Ft)
Liquid Line Connection and Quantity (Inch)
Gas Line Connection and Quantity (Inch)
Refrigerant
Factory Charge for Combined Lineset Length (Ft)
Factory Charge (Oz)
Charge Adjustment Over Precharge Length (Oz / Ft)
Compressor Number and Type

LMU36CHV
36,000 BTU Class
2 - 4 Indoor Units

40,000

18,000 ~ 30,000 ~ 36,000


19,200 ~ 32,000 ~ 38,400
13
22
3.6
9.7 / 8.43
1 / 208~230 / 60
16.6 / 25
4 x minimum 16# (ground included) stranded,
rated at 300V minimum
37-13/32 32-27/32 13
99.2
Cooling (DB) -20 ~ 48C (-4 ~ 118F)
Heating (WB) -20 ~ 18C (-4 ~ 64F)
52 / 55
10 ~ 82
246
50
25
1/4 x 4
3/8 x 4
R410A
50 feet
98.8
.22
1 Twin Rotary Inverter

Non-ducted indoor
Mixed ducted & non-ducted indoor
48,000
19,200 ~ 32,000 ~ 38,400
21,600 ~ 36,000 ~ 41,600
12.4
21
3.9
10.6 / 9.22
1 / 208~230 / 60
17.9 / 25
4 x minimum 16# (ground included) stranded,
rated at 300V minimum
37-13/32 32-27/32 13
99.2
-20 ~ 48C (-4 ~ 118F)
-20 ~ 18C (-4 ~ 64F)
52 / 55
10 ~ 82
246
50
25
1/4 x 4
3/8 x 4
R410A
75 feet
98.8
.22
1 Twin Rotary Inverter

Warranty: 5 years parts, 7 years compressor


Optional Accessories:
PQSH1200 Base Pan Heater
Contact LG Technical Support regarding Dry Contact options for external control at 866-543-8324
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

PAG-HS6
PAG-HS7
PQCA0

PAG-HS6
PAG-HS7
PQCA0

Note: LMU18CHV, LMU24CHV, LMU30CHV & LMU36CHV are never matched with a distributor box.
LMU480HV, LMU540HV & LMU600HV always require at least one distributor box.

Non-ducted ratings and capacities are shown with maximum indoor units connected. For Ducted or Mixed Ducted and Non-Ducted combinations,
refer to Engineering Manuals containing capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx
1

Rated capacities are based on the following conditions:


Cooling: - Indoor Temperature 26.7C (80F) DB / 19.4C (67F) WB
- Outdoor Temperature 35C (95F) DB / 23.9C (75F) WB
Heating: - Indoor Temperature 21.1C (70F) DB / 15.6C (60F) WB
All electrical wiring must comply with applicable local, provincial and national codes.

18

Multi F MAX Outdoor

Multi F MAX

-20C operation

48,000 - 54,000 BTU


Accessory Distributor Box(es) Required
LMU480HV
48,000 BTU Class
2 - 8 Indoor Units

Outdoor Model Number


Energy Star (non-ducted indoor units)

LMU540HV
54,000 BTU Class
2 - 8 Indoor Units

LG Technical Support will calculate LMU480HV & LMU540HV refrigerant charge for contractors
Call 866-543-8324 for Heating & Air Conditioning Technical Support
Capacity (BTU/hr)
Capacity1 (BTU/hr)
Connectable Indoor Units
Minimum - Maximum Sum Of Indoor Units3
EER (Indoor Non-Ducted)
SEER (Indoor Non-Ducted / Ducted / Mixed)
COP (Indoor Non-Ducted)
HSPF Region IV (Indoor Non-Ducted / Ducted / Mixed)
Power Supply ( / V /Hz)
Distributor Box(es) Required
Distributor Box Model Numbers

Accessory Branch Tee When Using Two Distributor Boxes


Connecting Wire Outdoor Unit To Distributor Box2:

Rated
Cooling (Min ~ Rated ~ Max)
Heating (Min ~ Rated ~ Max)

2 Port
3 Port
4 Port
4 Port Required for 3 Ton Air Handler

Connecting Wire Distributor Box To Indoor Unit2:


Operation Range

Cooling (DB)
Heating (WB)

Maximum Total Combined Piping (Ft)


Minimum / Maximum Lineset Length Outdoor Unit - Distributor Box(es) (Ft)
Minimum / Maximum Lineset Length Distributor Box - Indoor Unit (Ft)
Maximum Lineset Elevation Distributor Box - Indoor Unit (Ft)
Maximum Lineset Elevation Any Indoor Unit - Any Indoor Unit (Ft)
Maximum Lineset Vertical Separation Indoor - Indoor On Same Box (Ft)
Maximum Lineset Vertical Separation Outdoor - Any Indoor (Ft)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Refrigerant
Factory Charge (Lbs)
Factory Charge for Lineset Length(Ft)
Outdoor - Distributor Box
Distributor Box - Indoor
Charge Adjustment Over Precharge Length
Compressor Type
Dimension W x H x D (inch)
Net Weight (Lbs)
Sound Pressure (dBA)
Cooling
Heating

48,000
14,400~48,000~58,000
17,280 ~ 54,000 ~ 61,000
2-8
24,000 ~ 65,000
12.5
19.5 / 17.5 / 18.5
3.7
10 / 9.7 / 9.9
1 / 208~230 / 60
Yes
PMBD3620
PMBD3630
PMBD3640
PMBD3641
PMBL5620
4 x minimum 16# (ground included)
stranded, rated at 300V minimum
4 x minimum 18# (ground included)
stranded, rated at 300V minimum
-20 ~ 48C (-4 ~ 118F)
-20 ~ 18C (-4 ~ 64F)
475
10 ~ 180
10 ~ 50
50
50
33
100
3/8
3/4
R410A
9.7
16
130
Call 866-543-8324
1 Twin Rotary Inverter
37 13/32 54 11/32 13
213.8
54
56

54,000
14,000 ~ 52,500 ~ 63,200
15,467 ~ 58,000 ~ 64,000
2-8
24,000 ~ 73,000
10.3
18.5 / 15.8 / 17.1
3.1
8.7 / 8.3 / 8.3
1 / 208~230 / 60
Yes
PMBD3620
PMBD3630
PMBD3640
PMBD3641
PMBL5620
4 x minimum 16# (ground included)
stranded, rated at 300V minimum
4 x minimum 18# (ground included)
stranded, rated at 300V minimum
-20 ~ 48C (-4 ~ 118F)
-20 ~ 18C (-4 ~ 64F)
475
10 ~ 180
10 ~ 50
50
50
33
100
3/8
3/4
R410A
9.7
16
130
Call 866-543-8324
1 Twin Rotary Inverter
37 13/32 54 11/32 13
213.8
54
56

PAG-HS5
PAG-HS4
PQCA0

PAG-HS5
PAG-HS4
PQCA0

Warranty: 5 years parts, 7 years compressor


Optional Accessories:
PMBL5620 branch tee required when using two distributor boxes
PQSH1200 Base Pan Heater
Contact LG Technical Support regarding Dry Contact options for external control at 866-543-8324
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

Note: LMU18CHV, LMU24CHV, LMU30CHV & LMU36CHV are never matched with a distributor box.
LMU480HV, LMU540HV & LMU600HV always require at least one distributor box.
Non-ducted ratings and capacities are shown.
For Ducted or Mixed Ducted and Non-Ducted combinations, refer to Engineering Manuals available at http://LGcomfort.ca/en/engineering-resources.aspx
2
All electrical wiring must comply with applicable local, provincial and national codes.
3
High-static air handlers must be calculated at 1.3 times their rating when calculating indoor unit capacity.
Contact LG Technical Support for assistance in calculating indoor capacities with air handlers and LMU540HV systems at 866-543-8324
1

19

Multi F MAX Outdoor

Multi F MAX

-20C operation

60,000 BTU
Accessory Distributor Box(es) Required
LMU600HV
60,000 BTU Class
2 - 8 Indoor Units

Outdoor Model Number


Energy Star (non-ducted indoor units)

LG Technical Support will calculate LMU480HV & LMU540HV refrigerant charge for contractors
Call 866-543-8324 for Heating & Air Conditioning Technical Support
Capacity (BTU/hr)
Capacity1 (BTU/hr)
Connectable Indoor Units
Minimum - Maximum Sum Of Indoor Units3
EER (Indoor Non-Ducted)
SEER (Indoor Non-Ducted / Ducted / Mixed)
COP (Indoor Non-Ducted)
HSPF Region IV (Indoor Non-Ducted / Ducted / Mixed)
Power Supply ( / V /Hz)
Distributor Box(es) Required
Distributor Box Model Numbers

Accessory Branch Tee When Using Two Distributor Boxes


Connecting Wire Outdoor Unit To Distributor Box2:

Nominal
Cooling (Min ~ Max)
Heating (Min ~ Max)

2 Port
3 Port
4 Port
4 Port Required for 3 Ton Air Handler

Connecting Wire Distributor Box To Indoor Unit2:


Operation Range

Cooling (DB)
Heating (WB)
Minimum / Maximum Lineset Length Outdoor Unit - Distributor Box(es) (Ft)
Minimum / Maximum Lineset Length Distributor Box - Indoor Unit (Ft)
Maximum Lineset Elevation Distributor Box - Indoor Unit (Ft)
Maximum Lineset Elevation Any Indoor Unit - Any Indoor Unit (Ft)
Maximum Lineset Vertical Separation Indoor - Indoor On Same Box (Ft)
Maximum Lineset Vertical Separation Outdoor - Any Indoor (Ft)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Refrigerant
Factory Charge (Lbs)
Factory Charge for Lineset Length(Ft)
Outdoor - Distributor Box
Distributor Box - Indoor
Charge Adjustment Over Precharge Length
Compressor Type
Dimension W x H x D (inch)
Net Weight (Lbs)
Sound Pressure (dBA)
Cooling
Heating
Warranty: 5 years parts, 7 years compressor
Optional Accessories:
Contact LG Technical Support regarding Dry Contact options for external control at 866-543-8324
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

60,000
15,600 - 68,000
17,940 - 70,000
2-8
24,000 ~ 81,000
11.4
20.5 / 19.5 / 18.5
3.5
8.7 / 8 / 8.3
1 / 208~230 / 60
Yes
PMDB3620
PMDB3630
PMBD3640
PMBD3641
PMBL5620
4 x minimum 16# (ground included)
stranded, rated at 300V minimum
4 x minimum 18# (ground included)
stranded, rated at 300V minimum
-10 ~ 48C (14 ~ 118F)
-20 ~ 18C (-4 ~ 64F)
10 ~ 180
10 ~ 50
50
50
33
100
3/8
3/4
R410A
12.34
16
130
Call 866-543-8324
1 Twin Rotary Inverter
37 13/32 54 11/32 13
213.8
56
58

PAG-HS5
PAG-HS4
PQCA0

Note: LMU18CHV, LMU24CHV, LMU30CHV & LMU36CHV are never matched with a distributor box.
LMU480HV, LMU540HV & LMU600HV always require at least one distributor box.
Non-ducted ratings and capacities are shown.
For Ducted or Mixed Ducted and Non-Ducted combinations, refer to Engineering Manuals available at http://LGcomfort.ca/en/engineering-resources.aspx
2
All electrical wiring must comply with applicable local, provincial and national codes.
3
High-static air handlers must be calculated at 1.3 times their rating when calculating indoor unit capacity.
Contact LG Technical Support for assistance in calculating indoor capacities with air handlers and LMU540HV systems at 866-543-8324
1

20

Multi F Vertical Air Handler


LMVN
24,000 & 36,000 BTU
Vertical / Horizontal Left Convertibility & Auxiliary Heat
Indoor Model Number
Capacity1 (BTU/hr)
Compatible Outdoor Units (No Exceptions)
Distributor Box Compatibility

Controller Included3
WLAN Smart Phone Control
Air Filter Included4
Dimension W x H x D (Inch)
Supply Air Opening W x D (Inch)
Return Air Opening W x D (Inch)
Auxiliary Heater Compatibility

PMBD3620
PMBD3630
PMBD3640
PMBD3641

ANEH053B1 5kW
ANEH103B2 10kW

Power Supply ( / V /Hz)


Connecting Wire Outdoor To Indoor2: (LMU30CHV, LMU36CHV, LMU369HV)
Connecting Wire, Distributor Box Models To Indoor2:
(LMU480HV, LMU540HV + PMBD36xx)
Air Flow Rate cfm at 0.5 ESP Hi ~ Med ~ Low
Condensate Drain Connection (Inch)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Net Weight (Lbs)
Sound Pressure (dBA) Hi ~ Med ~ Low

LMVN240HV
24,000
LMU30CHV, LMU36CHV, LMU369HV,
LMU480HV, LMU540HV, LMU600HV
Yes
Yes
Yes
Yes
Yes, Non-Programmable
No
No
18 x 48 21/32 x 21 1/4
17 x 12 1/4
14 3/8 x 18 1/2
Yes
Yes
1 / 208~230 / 60
4 x minimum 16# (ground included)
stranded, rated at 300V minimum
4 x minimum 18# (ground included)
stranded, rated at 300V minimum
710 ~ 640 ~ 480
3/4 NPT
1/4
1/2
117
43 ~ 42 ~ 41

LMVN360HV
36,000
LMU480HV, LMU540HV, LMU600HV
No
No
No
Yes, required
Yes, Non-Programmable
No
No
18 x 48 21/32 x 21 1/4
17 x 12 1/4
14 3/8 x 18 1/2
Yes
Yes
1 / 208~230 / 60
N/A
4 x minimum 18# (ground included)
stranded, rated at 300V minimum
990 ~ 880 ~ 800
3/4 NPT
3/8
5/8
121
45 ~ 44 ~ 43

Warranty: 5 years parts

16x20x1 air filter not included, required separately


Required Accessories For Auxiliary Heat (not included):
PREMTB10U or PREMTA000 wired controller
ANEH053B1 5kW electric auxiliary heater or ANEH103B2 10kW electric auxiliary heater
Engineering Manuals are available at http://LGcomfort.ca/en/engineering-resources.aspx
All electrical wiring must comply with applicable local, provincial and national codes.

1
2

High-static air handlers must have correction factor added when adding total indoor unit capacity.
High-static air handler plus 1 or more non-high-static indoor = air handler X 1.3
Eg. LMVN240HV + LMN078HVT: LMVN240HV is 24,000 x 1.3 = 31,200 + LMN078HVT 7,000 = 38,200 BTU total indoor unit capacity.
Twin high-static air handlers require a 1.2 correction factor.
Eg. LMVN240HV + LMVN360HV: 24,000 x 1.2 = 28,800 + 36,000 x 1.2 = 43,200 BTU = 72,000 total indoor unit capacity..
Contact LG Technical Support for assistance in calculating indoor capacities with air handler systems at 866-543-8324

21

Multi F Horizontal Air Handler


LMHN
24,000 & 36,000 BTU
LMHN240HV
24,000
LMU30CHV, LMU36CHV, LMU369HV,
LMU480HV, LMU540HV, LMU600HV
Distributor Box Compatibility
PMBD3620
Yes
PMBD3630
Yes
PMBD3640
Yes
PMBD3641
Yes
Controller Included3
Yes, Non-Programmable
Controller Operating Range
Cooling
18 ~ 30C (64 ~ 86F)
Heating
16 ~ 30C (61 ~ 86F)
WLAN Smart Phone Control
No
Air Filter Type Included
Washable
Dimension W x H x D (Inch)
53 x 11 23/32 x 18 5/32
Supply Air Opening W x D (Inch)
33 x 7 1/2
Return Air Opening W x D (Inch)
42 1/4 x 8 1/2
Power Supply ( / V /Hz)
1 / 208~230 / 60
Connecting Wire, Distributor Box Models To Indoor2: (LMU30CHV, LMU36CHV, LMU369HV) 4 x minimum 16# (ground included) stranded,
rated at 300V minimum
Connecting Wire, Distributor Box Models To Indoor2:
4 x minimum 18# (ground included) stranded,
(LMU480HV, LMU540HV + PMBD36xx)
rated at 300V minimum
Air Flow Rate (cfm at 0.5 ESP) Hi ~ Med ~ Low
688 ~ 618 ~ 530
Condensate Connection OD (Inch)
1 1/4
Liquid Line Connection (Inch)
1/4
Gas Line Connection (Inch)
1/2
Net Weight (Lbs)
79.4
Sound Pressure (dBA) Hi ~ Med ~ Low
37 ~ 36 ~ 35
Indoor Model
Capacity1 (BTU/hr)
Compatible Outdoor Units (No Exceptions)

LMHN360HV
36,000
LMU480HV, LMU540HV, LMU600HV
No
No
No
Yes, required
Yes, Non-Programmable
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No
Washable
53 x 11 23/32 x 18 5/32
33 x 7 1/2
42 1/4 x 8 1/2
1 / 208~230 / 60
N/A
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
1130 ~ 953 ~ 706
1 1/4
3/8
5/8
90.4
44 ~ 42 ~ 40

Warranty: 5 years parts

Required Accessories For Auxiliary Heat (not included):


PREMTB10U or PREMTA000 wired controller
PRARH0 auxiliary heat relay
Optional Accessories:
PREMTB10U or PREMTA000 programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
PRARH0 Auxiliary Heat Relay (requires PREMTB10U wired controller)
Engineering Manuals are available at http://LGcomfort.ca/en/engineering-resources.aspx
All electrical wiring must comply with applicable local, provincial and national codes.
3
Non-programmable thermostat included. For auxiliary heat applications, PREMTB10U programmable controller & auxiliary heat relay PRARH0 required
1
2

High-static air handlers must have correction factor added when adding total indoor unit capacity.
High-static air handler plus 1 or more non-high-static indoor = air handler X 1.3
Eg. LMHN240HV + LMN078HVT: LMHN240HV is 24,000 x 1.3 = 31,200 + LMN078HVT 7,000 = 38,200 BTU total indoor unit capacity.
Twin high-static air handlers require a 1.2 correction factor.
Eg. LMHN240HV + LMVN360HV: 24,000 x 1.2 = 28,800 + 36,000 x 1.2 = 43,200 BTU = 72,000 total indoor unit capacity.
Contact LG Technical Support for assistance in calculating indoor capacities with air handler systems at 866-543-8324

22

Multi F Gloss White


LSN Universal Indoor /
LMN
7,000 - 12,000 BTU (LSN090HSV4 & LSN120HSV4 Universal Indoor Units)
System
Capacity1 (BTU/hr)
Controller
Controller operating range
WLAN Smart Phone Control (PCRCUDT3 required separately)
Dimension W x H x D (Inch)
Net Weight (Lbs)
Power Supply ( / V /Hz)
Running Current
Connecting Wire Outdoor To Indoor2:
(LMU18CHV, LMU24CHV, LMU30CHV, LMU36CHV,
LMU187HV, LMU247HV, LMU369HV)
Connecting Wire, Distributor Box Models To Indoor2:
(LMU480HV, LMU540HV + PMBD36xx)
Air Flow Rate (cfm) Max ~ Hi ~ Med ~ Low
Sound Pressure (dBA) Hi ~ Med ~ Low ~ Sleep
Condensate Switch Connection
Condensate hose connection OD (Inch)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Charge Adjustment Over Precharge Length (Oz / Ft)

Cooling
Heating

LMN078HVT
7,000 BTU Class
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
Yes
35 1/4 x 11 3/8 x 8 9/32
22.1
1 / 208~230 / 60
.2A
4 x minimum 16# (ground included)
stranded, rated at 300V minimum

LSN090HSV4
9,000 BTU Class
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
Yes
35 1/4 x 11 3/8 x 8 9/32
22.1
1 / 208~230 / 60
.2A
4 x minimum 16# (ground included)
stranded, rated at 300V minimum

LSN120HSV4
12,000 BTU Class
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
Yes
35 1/4 x 11 3/8 x 8 9/32
32
1 / 208~230 / 60
.3A
4 x minimum 16# (ground included)
stranded, rated at 300V minimum

4 x minimum 18# (ground included)


stranded, rated at 300V minimum
n/a ~ 198 ~ 177 ~ 162
n/a ~ 33 ~ 30 ~ 26
Yes
5/8
1/4
3/8
.22

4 x minimum 18# (ground included)


stranded, rated at 300V minimum
423 ~ 353 ~ 272 ~ 191
38 ~ 33 ~ 23 ~ 19
Yes
5/8
1/4
3/8
.22

4 x minimum 18# (ground included)


stranded, rated at 300V minimum
423 ~ 353 ~ 272 ~ 191
38 ~ 33 ~ 23 ~ 19
Yes
5/8
1/4
3/8
.22

Warranty: 5 years parts

LSN090HSV4 & LSN120HSV4 will be WLAN compatible with Multi F outdoor models with serial numbers beginning
512 (2015 December) and 6** (any 2016 production month)
Optional Accessories
PCRCUDT3 Wi-Fi Adapter for LG Smart AC
Programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
Auxiliary Heat Relay (see accessories page)
Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx


All electrical wiring must comply with applicable local, provincial and national codes.

23

Multi F Gloss White


LSN Universal Indoor /
LMN
15,000 - 24,000 BTU (LSN180HSV4 Universal Indoor Unit)
System
Capacity1 (BTU/hr)
Controller
Controller operating range

Cooling
Heating

WLAN Smart Phone Control (PCRCUDT3 required separately)


Dimension W x H x D (Inch)
Net Weight (Lbs)
Power Supply ( / V /Hz)
Running Current
Connecting Wire Outdoor To Indoor2:
(LMU18CHV, LMU24CHV, LMU30CHV, LMU36CHV,
LMU187HV, LMU247HV, LMU369HV)
Connecting Wire, Distributor Box Models To Indoor2:
(LMU480HV, LMU540HV + PMBD36xx)
Air Flow Rate (cfm) Max ~ Hi ~ Med ~ Low
Sound Pressure (dBA) Hi ~ Med ~ Low ~ Sleep
Condensate Switch Connection
Condensate hose connection OD (Inch)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Charge Adjustment Over Precharge Length (Oz / Ft)

LMN158HVT
15,000 BTU Class
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No
35 1/4 x 11 3/8 x 8 9/32
22.1
1 / 208~230 / 60
.2A
4 x minimum 16# (ground included)
stranded, rated at 300V minimum

LSN180HSV4
18,000 BTU Class
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
Yes
40 9/16 x 12 25/32 x 9 27/32
30.9
1 / 208~230 / 60
.2A
4 x minimum 16# (ground included)
stranded, rated at 300V minimum

LMN248HVT
24,000 BTU Class
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No
40 9/16 x 12 25/32 x 9 27/32
32
1 / 208~230 / 60
.3A
4 x minimum 16# (ground included)
stranded, rated at 300V minimum

4 x minimum 18# (ground included)


stranded, rated at 300V minimum
n/a ~ 371 ~ 318 ~ 247
n/a ~ 33 ~ 30 ~ 26
Yes
5/8
1/4
3/8
.22

4 x minimum 18# (ground included)


stranded, rated at 300V minimum
735 ~ 622 ~ 509 ~ 399
45 ~ 40 ~ 35 ~ 29
Yes
5/8
1/4
1/2
.22

4 x minimum 18# (ground included)


stranded, rated at 300V minimum
n/a ~ 720 ~ 600 ~ 466
n/a ~ 42 ~ 39 ~ 36
Yes
5/8
1/4
1/2
.22

Warranty: 5 years parts

LSN180HSV4 will be WLAN compatible with Multi F outdoor models with serial numbers beginning 512
(2015 December) and 6** (any 2016 production month)
Optional Accessories:
PCRCUDT3 Wi-Fi Adapter for LG Smart AC (LSN180HSV4 only)
Programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
Auxiliary Heat Relay (see accessories page)
Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx
All electrical wiring must comply with applicable local, provincial and national codes.

1
2

24

Multi F Art Cool


Mirror LAN
9,000 - 18,000 BTU (LAN090HSV4, LAN120HSV4 & LAN180HSV4 Universal Indoor Units)

WLAN Smart Phone Control

LAN090HSV4
9,000 BTU Class
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No

LAN120HSV4
12,000 BTU Class
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No

LAN180HSV4
18,000 BTU Class
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No

Dimension W x H x D (Inch)
Net Weight (Lbs)
Power Supply ( / V /Hz)
Running Current
Connecting Wire Outdoor To Indoor2: (LMU18CHV, LMU24CHV,
LMU30CHV, MU36CHV, LMU187HV, LMU247HV, LMU369HV)

35 1/4 x 11 3/8 x 8 1/16


23.1
1 / 208~230 / 60
.2A
4 x minimum 16# (ground included)
stranded, rated at 300V minimum

35 1/4 x 11 3/8 x 8 1/16


23.1
1 / 208~230 / 60
.2A
4 x minimum 16# (ground included)
stranded, rated at 300V minimum

40 9/16 x 12 25/32 x 9 21/32


32
1 / 208~230 / 60
.3A
4 x minimum 16# (ground included)
stranded, rated at 300V minimum

Connecting Wire, Distributor Box Models To Indoor2:


(LMU480HV, LMU540HV + PMBD36xx)

4 x minimum 18# (ground included) 4 x minimum 18# (ground included) 4 x minimum 18# (ground included)
stranded, rated at 300V minimum stranded, rated at 300V minimum stranded, rated at 300V minimum

Air Flow Rate (cfm) Max ~ Hi ~ Med ~ Low


Sound Pressure (dBA) Hi ~ Med ~ Low ~ Sleep
Condensate Switch Connection
Condensate hose connection OD (Inch)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Charge Adjustment Over Precharge Length (Oz / Ft)

423 ~ 353 ~ 272 ~ 191


8 ~ 33 ~ 23 ~ 19
Yes
5/8
1/4
3/8
.22

Indoor Model Number


Capacity1 (BTU/hr)
Controller
Controller operating range

Cooling
Heating

423 ~ 353 ~ 272 ~ 191


8 ~ 33 ~ 23 ~ 19
Yes
5/8
1/4
3/8
.22

735 ~ 622 ~ 509 ~ 399


45 ~ 40 ~ 35 ~ 29
Yes
5/8
1/4
1/2
.22

Warranty: 5 years parts

LAN180HSV4 will use a 1/4 & 1/2 lineset with any Multi F outdoor unit.
LAN180HSV4 will use a 3/8 & 5/8 lineset with LSU180HSV4.
Optional Accessories:
PREMTB10U programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
PRARS0 Auxiliary Heat Relay (requires PREMTB10U wired controller)
Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx
All electrical wiring must comply with applicable local, provincial and national codes.

1
2

25

Multi F Art Cool Gallery


LMAN
9,000 & 12,000 BTU, Accepts Any 20 X 20 Print
Indoor Model Number
Capacity1 (BTU/hr)
Controller
Controller operating range

Cooling
Heating

WLAN Smart Phone Control


Dimension W x H x D (Inch)
Net Weight (Lbs)
Power Supply ( / V /Hz)
Running Current
Connecting Wire Outdoor To Indoor: (LMU18CHV, LMU24CHV, LMU30CHV,
LMU36CHV, LMU187HV, LMU247HV, LMU369HV)
Connecting Wire, Distributor Box Models To Indoor2:
(LMU480HV, LMU540HV + PMBD36xx)
Air Flow Rate (cfm) Hi ~ Med ~ Low
Sound Pressure (dBA) Hi ~ Med ~ Low
Condensate Switch Connection
Condensate hose connection OD (Inch)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Charge Adjustment Over Precharge Length (Oz / Ft)

LMAN097HVP
9,000 BTU Class
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No
23 5/8 x 23 5/8 x 5 25/32
32
1 / 208~230 / 60
.2A
4 x minimum 16# (ground included) stranded,
rated at 300V minimum
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
272 ~ 208 ~ 155
39 ~ 35 ~31
Yes
5/8
1/4
3/8
.22

LMAN127HVP
12,000 BTU Class
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No
23 5/8 x 23 5/8 x 5 25/32
32
1 / 208~230 / 60
.2A
4 x minimum 16# (ground included) stranded,
rated at 300V minimum
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
314 ~ 258 ~ 198
42 ~ 38 ~ 34
Yes
5/8
1/4
3/8
.22

Warranty: 5 years parts


Optional Accessories:
Programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
Auxiliary Heat Relay (see accessories page)
Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx
All electrical wiring must comply with applicable local, provincial and national codes.

1
2

26

Multi F Ceiling Cassette


LMCN
PT-UQC Grille Required as Accessory

9,000 BTU
Indoor Model Number
Capacity1 (BTU/hr)
Controller
Controller operating range

Cooling
Heating

WLAN Smart Phone Control


Unit Dimension W x H x D (Inch)
Net Weight Unit (Lbs)
PT-UQC Grille Required As Separate Accessory, Not Included With Indoor Unit
Grille Dimension W x H x D (Inch)
Net Weight Grille (Lbs)
Power Supply ( / V /Hz)
Running Current
Connecting Wire Outdoor To Indoor2: (LMU18CHV, LMU24CHV, LMU30CHV, LMU36CHV, LMU187HV,
LMU247HV, LMU369HV)
Connecting Wire, Distributor Box Models To Indoor2:
(LMU480HV, LMU540HV + PMBD36xx)
Air Flow Rate (cfm) Hi ~ Med ~ Low
Sound Pressure (dBA) Hi ~ Med ~ Low
Condensate Connection OD (Inch)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Charge Adjustment Over Precharge Length (Oz / Ft)
Warranty: 5 years parts

LMCN097HV
9,000 BTU Class
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No
22 7/16 x 8 7/16 x 22 7/16
33.1
27 9/16 x 7/8 x 27 9/16
6.6
1 / 208~230 / 60
.25A
4 x minimum 16# (ground included) stranded,
rated at 300V minimum
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
300 ~ 265 ~ 230
36 ~ 33 ~ 30
1 1/4
1/4
3/8
.22

12,000 - 18,000 BTU


Indoor Model Number
Capacity1 (BTU/hr)
Controller
Controller operating range

Cooling
Heating

WLAN Smart Phone Control


Unit Dimension W x H x D (Inch)
Net Weight Unit (Lbs)
PT-UQC Grille Required As Separate Accessory, Not Included With Indoor Unit
Grille Dimension W x H x D (Inch)
Net Weight Grille (Lbs)
Power Supply ( / V /Hz)
Running Current
Connecting Wire Outdoor To Indoor2: (LMU18CHV, LMU24CHV, LMU30CHV,
LMU36CHV, LMU187HV, LMU247HV, LMU369HV)
Connecting Wire, Distributor Box Models To Indoor2:
(LMU480HV, LMU540HV + PMBD36xx)
Air Flow Rate (cfm) Hi ~ Med ~ Low
Sound Pressure (dBA) Hi ~ Med ~ Low
Condensate Connection OD (Inch)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Charge Adjustment Over Precharge Length (Oz / Ft)
Warranty: 5 years parts

LMCN125HV
12,000 BTU Class
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No
22 7/16 x 8 7/16 x 22 7/16
30.9

LMCN185HV
18,000 BTU Class
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No
22 7/16 x 8 7/16 x 22 7/16
33.1

27 9/16 x 7/8 x 27 9/16


6.6
1 / 208~230 / 60
.25A
4 x minimum 16# (ground included) stranded,
rated at 300V minimum
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
335 ~ 283 ~ 247
38 ~ 35 ~ 32
1 1/4
1/4
3/8
.22

27 9/16 x 7/8 x 27 9/16


6.6
1 / 208~230 / 60
.25A
4 x minimum 16# (ground included) stranded,
rated at 300V minimum
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
459 ~ 424 ~ 388
36 ~ 33 ~ 30
1 1/4
1/4
1/2
.22

Optional Accessories:
PREMTB10U programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
PRARH0 Auxiliary Heat Relay (requires PREMTB10U wired controller)

1
Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx
2
All electrical wiring must comply with applicable local, provincial and national codes.

27

Multi F Low-Static Air Handler


LMDN
9,000 - 18,000 BTU

LMDN096HV

LMDN096HV
9,000 BTU Class
Wired Non-Programmable
Cooling
18 ~ 30C (64 ~ 86F)
Heating
16 ~ 30C (61 ~ 86F)
WLAN Smart Phone Control
No
Unit Dimension W x H x D (Inch)
27 9/16 x 7 15/32 x 27 9/16
Net Weight Unit (Lbs)
38.6
Air Filter Type Included
Washable
Power Supply ( / V /Hz)
1 / 208~230 / 60
Running Current
.25A
Connecting Wire Outdoor To Indoor2: (LMU18CHV, LMU24CHV, LMU30CHV, 4 x minimum 16# (ground
LMU36CHV, LMU187HV, LMU247HV, LMU369HV)
included) stranded, rated at
300V minimum
Connecting Wire, Distributor Box Models To Indoor2:
4 x minimum 18# (ground
(LMU480HV, LMU540HV + PMBD36xx)
included) stranded, rated at
300V minimum
Air Flow Rate (cfm 0.2 ESP) Hi ~ Med ~ Low
318 ~ 247 ~ 194
Sound Pressure (dBA)
30 ~ 26 ~ 23
Condensate Connection OD (Inch)
1 1/4
Liquid Line Connection (Inch)
1/4
Gas Line Connection (Inch)
3/8
Charge Adjustment Over Precharge Length (Oz / Ft)
.22
Indoor Model Number
Capacity1 (BTU/hr)
Controller
Controller operating range

Warranty: 5 years parts


Optional Accessories
Programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
Auxiliary Heat Relay (see accessories page)
Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx
All electrical wiring must comply with applicable local, provincial and national codes.

1
2

28

LMDN126HV & LMDN186HV


LMDN126HV
12,000 BTU Class
Wired Non-Programmable
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No
35 7/16 x 7 15/32 x 27 9/16
50.7
Washable
1 / 208~230 / 60
.25A
4 x minimum 16# (ground
included) stranded, rated at
300V minimum
4 x minimum 18# (ground
included) stranded, rated at
300V minimum
353 ~ 300 ~ 247
31 ~ 28 ~ 27
1 1/4
1/4
3/8
.22

LMDN186HV
18,000 BTU Class
Wired Non-Programmable
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No
35 7/16 x 7 15/32 x 27 9/16
50.7
Washable
1 / 208~230 / 60
.25A
4 x minimum 16# (ground
included) stranded, rated at
300V minimum
4 x minimum 18# (ground
included) stranded, rated at
300V minimum
530 ~ 441 ~ 353
36 ~ 34 ~ 31
1 1/4
1/4
1/2
.22

Multi F & Multi F MAX Efficiency /


Capacity Table
System

LMU18CHV

LMU24CHV

LMU30CHV

LMU36CHV

LMU480HV

LMU540HV

LMU600HV

Combined With

Rated Cooling
Capacity (BTU/h)

EER
(95F)

SEER

Rated Heating
Capacity (BTU/h)

COP
(47F)

HSPF

Low Heating
COP
Capacity (BTU/h) (17F)

Non-Ducted Indoor Units

17,000

13.0

22.0

22,000

3.2

9.7

13,500

2.4

Ducted Units

14,000

10.7

17.2

19,800

2.9

9.7

13,000

2.4

Mixed Non-Ducted and


Ducted Indoor Units

15,500

11.8

19.6

20,900

3.0

9.7

13,250

2.4

Non-Ducted Indoor Units

20,000

13.5

21.7

24,000

3.9

10.6

14,500

2.7

Ducted Units

17,800

11.5

17.5

22,500

3.4

9.8

14,000

2.5

Mixed Non-Ducted and


Ducted Indoor Units

18,900

12.5

19.6

23,250

3.7

10.2

14,250

2.6

Non-Ducted Indoor Units

30,000

13.0

22.0

32,000

3.8

10

19,600

2.7

Ducted Units

27,400

11.0

18.2

33,000

3.5

9.7

19,000

2.5

Mixed Non-Ducted and


Ducted Indoor Units

28,700

12.0

20.1

32,500

3.6

9.85

19,300

2.6

Non-Ducted Indoor Units

32,000

13.0

22.0

36,000

3.9

10.0

20,000

2.6

Ducted Units

28,000

11.0

18.2

34,000

3.5

9.7

19,500

2.4

Mixed Non-Ducted and


Ducted Indoor Units

30,000

12.0

20.1

35,000

3.7

9.9

19,750

2.5

Non-Ducted Indoor Units

48,000

12.5

19.5

54,000

TBD

10

35,000

TBD

Ducted Units

44,000

10.8

17.5

50,000

3.3

9.7

32,370

3.0

Mixed Non-Ducted and


Ducted Indoor Units

46,000

11.6

18.5

52,000

3.5

9.9

33,400

3.2

Non-Ducted Indoor Units

52,500

10.3

18.4

58,000

3.1

8.7

36,600

2.6

Ducted Units

51,000

10.0

15.8

58,000

3.0

8.3

38,500

2.6

Mixed Non-Ducted and


Ducted Indoor Units

51,750

10.15

17.1

58,000

3.1

8.5

37,550

2.6

Non-Ducted Indoor Units

60,000

11.4

20.5

64,000

3.5

11.0

41,000

2.7

Ducted Units

58,000

10.5

19.5

64,000

3.31

10.5

43,000

2.8

Mixed Non-Ducted and


Ducted Indoor Units

59,000

10.94

19.5

64,000

3.41

10.8

42,000

2.7

Energy
Star

LMU18CHV, LMU24CHV, LMU30CHV, LMU36CHV:


Rated capacity is rated 0 ft. above sea level with 25 ft. of refrigerant line per indoor unit and a 0 ft. level difference between outdoor and indoor units.
All capacities are net with a combination ratio between 95 105%.
Rated cooling capacity rating obtained with air entering the indoor unit at 80F dry bulb (DB) and 67F wet bulb (WB) and outdoor ambient conditions of
95F dry bulb (DB) and 75F wet bulb (WB).
Rated heating capacity rating obtained with air entering the indoor unit at 70F dry bulb (DB) and 60F wet bulb (WB) and outdoor ambient conditions of
47F dry bulb (DB) and 43F wet bulb (WB).

LMU480HV, LMU540HV, LMU600HV:
Rated capacity is rated 0 ft. above sea level with Piping Length as Main pipe (16.4 ft.) + Branch pipe (98.4 ft.) = 115 ft., and a 0 ft. level difference
between outdoor and indoor units.
All capacities are net with a combination ratio between 95 105%.
Rated cooling capacity rating obtained with air entering the indoor unit at 80F dry bulb (DB) and 67F wet bulb (WB) and outdoor ambient conditions of
95F dry bulb (DB) and 75F wet bulb (WB).
Rated heating capacity rating obtained with air entering the indoor unit at 70F dry bulb (DB) and 60F wet bulb (WB) and outdoor ambient conditions of
47F dry bulb (DB) and 43F wet bulb (WB).

All Models:
Rated capacity is certified under AHRI Standard 210 / 240. EER, IEER, COP, and HSPF are subject to change. See www.ahrinet.org for the latest values.

29

Art Cool Prestige


9 ~ 12 ~ 18 ~ 24,000 BTU Models

23 %

Superior Air Flow

Larger

(Fan Size)

Fan & nozzle design for 547 -812 maximum cfm

Previous: 3-1/4in

New: 4in

Forest

LG Air
Conditioner

Conventional
On / Off

26dB(A)

32dB(A)

24 dB(A)

Whisper-quiet Air Flow


17dB(A) Sleep Mode is quieter than a library

(low fan speed)

Library

36dB(A)

LG Air
Conditioner

17dB(A)

With low sound levels, LG air


conditioners provide quiet peace of
mind to the user.

(sleep mode)

Wi
adaptor

Beautiful Art Cool


Appearance
White pearlized finish and rounded surfaces
enhance any room

Wi-Fi

Heating Operation Down to

-25C / -13F

 igh Efficiency in Heating


H
and Cooling Modes

LA180HYV1 produces 18,000 BTU


maximum at -18C

Up to 27.5 SEER / 15.65 EER /


12.5 HSPF / 4.63 COP

30

ART COOL PRESTIGE

Art Cool Prestige

-25C operation

9,000 & 12,000 BTU


System

LA090HYV1
9,000 BTU

LA120HYV
12,000 BTU

At -8C
At -15C
At -25C

LAN090HYV1
LAU090HYV1
9,000 / 11,000
11,990 (109%)
11,220 (102%)
7,920 (72%)
15.65
27.5
12 / 10.4
4.6

LAN120HYV
LAU120HYV
12,000 / 13,600
14,650 (108%)
13,720 (101%)
9,520 (70%)
14.12
25.5
11.5 / 10.0
4.63

Cooling
Heating

34 7/16 x 11 5/8 x 9 1/4


24.25
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded, rated at 300V
minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
547~494~417~283
38 (39 heating)~33~25~17
5/8 male
Yes
Yes
Yes

34 7/16 x 11 5/8 x 9 1/4


24.25
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded, rated at 300V
minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
547~494~417~283
38 (39 heating) ~33~25~17
5/8 male
Yes
Yes
Yes

-10 ~ 48C (14 ~ 118F)


-25 ~ 24C (-13 ~ 75F)
1 / 208~230 / 60
15
11.2
10 - 66
33
1/4
3/8
R410A
40.6
.22
1 Twin Rotary Inverter
72.75
30 5/16 x 21 1/2 x 11 5/16
45

-10 ~ 48C (14 ~ 118F)


-25 ~ 24C (-13 ~ 75F)
1 / 208~230 / 60
15
11.2
10 - 66
33
1/4
3/8
R410A
40.6
.22
1 Twin Rotary Inverter
72.75
31 5/16 x 21 1/2 x 11 5/16
45

PAG-HS0
PAG-HS3
PQCA0

PAG-HS0
PAG-HS3
PQCA0

Energy Star

Indoor Model
Outdoor Model

Capacity1 (BTU/hr) Rated Cooling / Heating


Maximum Heating Output
E.E.R.
S.E.E.R.
H.S.P.F (Region IV / V)
C.O.P.
Indoor
Dimension W x H x D (Inch)
Net Weight (Lbs)
Power Supply From Outdoor Unit ( / V /Hz)
Connecting Wire Outdoor To Indoor:
Controller
Controller Operating Range
Air Flow Rate (cfm) Max~Hi~Med~Low
Sound Pressure (dBA) Hi~Med~Low~Sleep
Condensate connection OD (Inch)
Condensate Sensor Connection
Cooling-only Option
WLAN Smart Phone Control (PCRCUDT3 required separately)
Outdoor
Operation Range
Power Supply ( / V /Hz)
MOP
MCA
Minimum ~ Maximum Lineset Length (Ft)
Maximum Lineset Elevation (Ft)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Refrigerant
Factory Charge (Oz) - Sufficient for 41' lineset
Charge Adjustment Over Precharge Length (Oz / Ft)
Compressor Number and Type
Net Weight (Lbs)
Dimension W x H x D (Inch)
Sound Pressure (dBA)

Cooling (DB)
Heating (WB)

Warranty: 5 years parts, 10 years compressor


Optional Accessories
PCRCUDT3 Wi-Fi Adapter for LG Smart AC
PREMTB10U programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
PRARS1 Auxiliary Heat Relay (requires PREMTB10U wired controller)
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx


All electrical wiring must comply with applicable local, provincial and national codes.

1
2

31

ART COOL PRESTIGE

Art Cool Prestige

-25C operation

18,000 & 24,000 BTU


System

LA180HYV1
18,000 BTU

LA240HYV1
24,000 BTU

At -8C
At -15C
At -25C

LAN180HYV1
LAU180HYV1
18,000 / 22,000
22,340 (102%)
19,300 (88%)
14,060 (64%)
13.48
24
12.5 / 10.9
3.81

LAN240HYV1
LAU240HYV1
22,000 / 27,000
27,410 (108%)
23,690 (88%)
17,250 (64%)
12.5
22
12 / 10.4
3.61

Cooling
Heating

45 3/32 x 11 15/32 x 11 13/16


15
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded, rated at 300V
minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
547~494~417~283
38 (39 heating)~33~25~17
5/8 male
Yes
Yes
Yes

45 3/32 x 11 15/32 x 11 13/16


15
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded, rated at 300V
minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
547~494~417~283
38 (39 heating) ~33~25~17
5/8 male
Yes
Yes
Yes

-10 ~ 48C (14 ~ 118F)


-25 ~ 24C (-13 ~ 75F)
1 / 208~230 / 60
25
19
10 - 98
66
3/8
5/8
R410A
67
.38
1 Twin Rotary Inverter
121.3
34 1/4 x 31 1/2 x 12 19/32
55

-10 ~ 48C (14 ~ 118F)


-25 ~ 24C (-13 ~ 75F)
1 / 208~230 / 60
25
19
10 - 98
66
3/8
5/8
R410A
67
.38
1 Twin Rotary Inverter
121.3
34 1/4 x 31 1/2 x 12 19/32
55

PAG-HS8
PAG-HS2
PQCA0

PAG-HS8
PAG-HS2
PQCA0

Energy Star

Indoor Model
Outdoor Model

Capacity1 (BTU/hr) Rated Cooling / Heating


Maximum Heating Output
E.E.R.
S.E.E.R.
H.S.P.F (Region IV / V)
C.O.P.
Indoor
Dimension W x H x D (Inch)
Net Weight (Lbs)
Power Supply From Outdoor Unit ( / V /Hz)
Connecting Wire Outdoor To Indoor:
Controller
Controller Operating Range
Air Flow Rate (cfm) Max~Hi~Med~Low
Sound Pressure (dBA) Hi~Med~Low~Sleep
Condensate connection OD (Inch)
Condensate Sensor Connection
Cooling-only Option
WLAN Smart Phone Control (PCRCUDT3 required separately)
Outdoor
Operation Range
Power Supply ( / V /Hz)
MOP
MCA
Minimum ~ Maximum Lineset Length (Ft)
Maximum Lineset Elevation (Ft)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Refrigerant
Factory Charge (Oz) - Sufficient for 25' lineset
Charge Adjustment Over Precharge Length (Oz / Ft)
Compressor Number and Type
Net Weight (Lbs)
Dimension W x H x D (Inch)
Sound Pressure (dBA)

Cooling (DB)
Heating (WB)

Warranty: 5 years parts, 10 years compressor


Optional Accessories
PCRCUDT3 Wi-Fi Adapter for LG Smart AC
Programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
Auxiliary Heat Relay (see accessories page)
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx


All electrical wiring must comply with applicable local, provincial and national codes.

1
2

32

Art Cool Mirror


Universal Indoor /
Outdoor Unit

ART COOL MIRROR

-20C operation

9,000 & 12,000 BTU


System

LA090HSV4
9,000 BTU

LA120HSV4
12,000 BTU

At -8C
At -15C
At -25C

LAN090HSV4
Match with LSU090HSV4 & all Multi F
LSU090HSV4
9,000 / 10,800
8,856 (82%)
7,452 (69%)
7,236 (67%)
13.29
21.5
10.8 / 9.4
4.51

LAN120HSV4
Match with LSU120HSV4 & all Multi F
LSU120HSV4
11,200 / 13,300
10,906 (82%)
9,177 (69%)
8,911 (67%)
12.5
21.5
11.0 / 9.6
3.90

Cooling
Heating

34 13/16 x 11 1/4 x 8 1/16


24.3
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded, rated at
300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
423~353~272~191
38 (39 heating)~33~23~19
5/8 male
Yes
No
No

34 13/16 x 11 1/4 x 8 1/16


24.3
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded, rated at
300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
423~353~272~191
38 (39 heating)~33~23~19
5/8 male
Yes
No
No

-10 ~ 48C (14 ~ 118F)


-20 ~ 24C (-13 ~ 75F)
1 / 208~240 / 60
15
10
10 ~ 66
33
1/4
3/8
R410A
35.3 ounces
.22
1 Rotary Inverter
81.6
30 5/16 x 21 1/2 x 11 5/16
45

-10 ~ 48C (14 ~ 118F)


-20 ~ 24C (-13 ~ 75F)
1 / 208~240 / 60
15
10
10 ~ 66
33
1/4
3/8
R410A
35.3 ounces
.22
1 Rotary Inverter
81.6
30 5/16 x 21 1/2 x 11 5/16
45

PAG-HS0
PAG-HS3
PQCA0

PAG-HS0
PAG-HS3
PQCA0

Energy Star

Indoor Model
Outdoor Model

Capacity1 (BTU/hr) Rated Cooling / Heating


Maximum Heating Output
E.E.R.
S.E.E.R.
H.S.P.F. (Region V / IV)
C.O.P.
Indoor
Dimension W x H x D (Inch)
Net Weight (Lbs)
Power Supply From Outdoor Unit ( / V /Hz)
Connecting Wire Outdoor To Indoor2:
Controller
Controller Operating Range
Air Flow Rate (cfm) Max~Hi~Med~Low
Sound Pressure (dBA) Hi~Med~Lo~Sleep
Condensate Connection OD (Inch)
Condensate Sensor Connection
Cooling-only Switch
WLAN Smart Phone Control

Outdoor
Operation Range
Power Supply ( / V /Hz)
MOP
MCA
Minimum ~ Maximum Lineset Length (Ft)
Maximum Lineset Elevation (Ft)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Refrigerant
Factory Charge (Oz) - Sufficient for 41' lineset
Charge Adjustment Over Precharge Length (Oz / Ft)
Compressor Number & Type
Net Weight (Lbs)
Dimension W x H x D (Inch)
Sound Pressure dBA

Cooling (DB)
Heating (WB)

Warranty: 5 years parts, 10 years compressor


Optional Accessories:
Programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
PRARS0 Auxiliary Heat Relay (requires wired controller)
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx


All electrical wiring must comply with applicable local, provincial and national codes.

33

Art Cool Mirror


Universal Indoor /
Outdoor Unit

ART COOL MIRROR

-20C operation

18,000 & 24,000 BTU


System
Energy Star

Indoor Model
Outdoor Model
Capacity1 (BTU/hr) Rated Cooling / Heating
Maximum Heating Output

At -8C
At -15C
At -25C

E.E.R.
S.E.E.R.
H.S.P.F. (Region V / IV)
C.O.P.
Indoor
Dimension W x H x D (Inch)
Net Weight (Lbs)
Power Supply From Outdoor Unit ( / V /Hz)
Connecting Wire Outdoor To Indoor2:
Controller
Controller Operating Range
Air Flow Rate (cfm) Max~Hi~Med~Low
Sound Pressure (dBA) Hi~Med~Lo~Sleep

Cooling
Heating

Condensate Connection OD (Inch)


Condensate Sensor Connection
Cooling only Switch

WLAN Smart Phone Control

Outdoor
Operation Range
Power Supply ( / V /Hz)
MOP
MCA
Minimum ~ Maximum Lineset Length (Ft)
Maximum Lineset Elevation (Ft)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Refrigerant
Factory Charge (Oz) - Sufficient for 25' lineset
Charge Adjustment Over Precharge Length (Oz / Ft)
Compressor Number & Type
Net Weight (Lbs)
Dimension W x H x D (Inch)
Sound Pressure (dBA)
Cooling-only Switch
Condensate Sensor Connection
WLAN Smart Phone App Control
Warranty: 5 years parts, 10 years compressor
Optional Accessories:
Programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
PRARS0 Auxiliary Heat Relay (requires wired controller)
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

Cooling (DB)
Heating (WB)

LA180HSV4
18,000 BTU

LA240HSV2
24,000 BTU

LAN180HSV4
Match with LSU180HSV4 & all Multi F
except LMU18CHV / LMU187HV
LSU180HSV4
18,200 / 22,000
18,040 (82%)
15,180 (69%)
14,740 (67%)
12.58
20.5
9.7 / 8.4
3.66

LAN240HSV2

40 9/16 x 12 13/16 x 9 11/16


37.5
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded, rated at
300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
735~622~509~399
45~40~35~29
5/8 male
Yes
No

40 9/16 x 12 13/16 x 9 11/16


37.5
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded, rated at
300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
777~632~526~399
45~40~35~29
5/8 male
Yes
No

10.8
20
10 (Region IV)
3.03

No

No

-10 ~ 48C (14 ~ 118F)


-20 ~ 24C (-13 ~ 75F)
1 / 208~240 / 60
30
19
10 ~ 98
50
3/8
5/8
R410A
63.5 ounces
.38
1 Rotary Inverter
132.3
34 1/4 x 31 1/2 x 12 19/32
53
No
Yes
No

-10 ~ 48C (14 ~ 118F)


-20 ~ 24C (-13 ~ 75F)
1 / 208~240 / 60
30
19
10 ~ 98
50
3/8
5/8
R410A
63.5 ounces
.38
1 Rotary Inverter
132.3
34 1/4 x 31 1/2 x 12 19/32
53
No
Yes
No

LAN180HSV4 will use a 1/4 & 1/2 lineset with any Multi F outdoor unit.
LAN180HSV4 will use a 3/8 & 5/8 lineset with LSU180HSV4.

PAG-HS8
PAG-HS2
PQCA0

Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx


All electrical wiring must comply with applicable local, provincial and national codes.

34

LAU240HSV2
22,000 / 27,600
22,800 at 0C
16,380 at -15C

PAG-HS8
PAG-HS2
PQCA0

Gloss White
Universal Indoor /
Outdoor Unit

SINGLE ZONE

-20C operation

9,000 & 12,000 BTU


System
Energy Star

Indoor Model
Outdoor Model
Capacity1 (BTU/hr) Rated Cooling / Heating
Maximum Heating Output

At -8C
At -15C
At -20C

E.E.R.
S.E.E.R.
H.S.P.F. (Region IV / V)
C.O.P.
Indoor
Dimension Inches W x H x D
Net Weight (Lbs)
Power Supply ( / V /Hz)
Connecting Wire Outdoor To Indoor2:
Controller
Controller Operating Range

Cooling
Heating

Air Flow Rate (cfm) Max~Hi~Med~Low


Sound Pressure (dBA) Hi~Med~Low~Sleep
Condensate Connection OD (Inch)
Condensate Sensor Connection
Cooling-only Option
WLAN Smart Phone Control (PCRCUDT3 required separately)
Outdoor
Operation Range
Cooling (DB)
Heating (WB)
Power Supply ( / V /Hz)
MOP
MCA
Minimum ~ Maximum Lineset Length (Ft)
Maximum Lineset Elevation (Ft)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Refrigerant
Factory Charge (Oz) - Sufficient for 41' lineset
Charge Adjustment Over Precharge Length (Oz / Ft)
Compressor Number and Type
Net Weight (Lbs)
Dimension W x H x D (Inch)
Sound Pressure (dBA)

LS090HSV4
9,000 BTU

LS120HSV4
12,000 BTU

LSN090HSV4
Match with LSU090HSV4 & all Multi F
LSU090HSV4
Match with LSN090HSV4 & LAN090HSV4
9,000 / 10,800
8,856 (82%)
7,452 (69%)
7,236 (67%)
13.3
21.5
10.8 / 9.4
4.51

LSN120HSV4
Match with LSU120HSV4 & all Multi F
LSU120HSV4
Match with LSN120HSV4 & LAN120HSV4
11,200 / 13,300
10,906 (82%)
9,177 (69%)
8,911 (67%)
12.5
21.5
11 / 9.6
3.90

34 13/16 x 11 1/4 x 8 1/4


19.4
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
423~353~272~191
38~33~23~19
5/8 male
Yes
Yes
Yes

34 13/16 x 11 1/4 x 8 1/4


19.4
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
423~353~272~191
38~33~23~19
5/8 male
Yes
Yes
Yes

-10 ~ 48C (14 ~ 118F)


-20 ~ 24C (-4 ~ 75F)
1 / 208~230 / 60
15
10
10 ~ 66
33
1/4
3/8
R410A
35.3
.22
1 Rotary Inverter
75
30 5/16 x 21 1/2 x 11 5/16
45

-10 ~ 48C (14 ~ 118F)


-20 ~ 24C (-4 ~ 75F)
1 / 208~230 / 60
15
10
10 ~ 66
33
1/4
3/8
R410A
35.3
.22
1 Rotary Inverter
75
31 5/16 x 21 1/2 x 11 5/16
45

PAG-HS0
PAG-HS3
PQCA0

PAG-HS0
PAG-HS3
PQCA0

Warranty: 5 years parts, 10 years compressor


Optional Accessories:
PREMTB10U programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
PRARS1 Auxiliary Heat Relay (requires PREMTB10U wired controller)
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx


All electrical wiring must comply with applicable local, provincial and national codes.

35

Gloss White
Universal Indoor /
Outdoor Unit

SINGLE ZONE

-20C operation

18,000 & 24,000 BTU


System
Energy Star

Indoor Model
Outdoor Model
Capacity1 (BTU/hr) Rated Cooling / Heating
Maximum Heating Output

At -8C
At -15C
At -20C

E.E.R.
S.E.E.R.
H.S.P.F. (Region IV / V)
C.O.P.
Indoor
Dimension Inches W x H x D (Inch)
Net Weight (Lbs)
Power Supply ( / V /Hz)
Connecting Wire Outdoor To Indoor2:
Controller
Controller Operating Range

Cooling
Heating

Air Flow Rate (cfm) Max~Hi~Med~Low


Sound Pressure (dBA) Hi~Med~Low~Sleep
Condensate Connection OD (Inch)
Condensate Sensor Connection
Cooling-only Option
WLAN Smart Phone Control (PCRCUDT3 required separately)
Outdoor
Operation Range
Cooling (DB)
Heating (WB)
Power Supply ( / V /Hz)
MOP
MCA
Minimum ~ Maximum Lineset Length (Ft)
Maximum Lineset Elevation (Ft)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Refrigerant
Factory Charge (Oz) - Sufficient for 25' lineset
Charge Adjustment Over Precharge Length (Oz / Ft)
Compressor Number and Type
Net Weight (Lbs)
Dimension W x H x D (Inch)
Sound Pressure (dBA)

LS180HSV4
18,000 BTU

LS240HSV3
24,000 BTU

LSN180HSV4
Match with LSU180HSV4 & all Multi F
except LMU18CHV / LMU187HV
LSU180HSV4
Match with LSN180HSV4 & LAN180HSV4
18,200 / 22,000
18,040 (82%)
15,180 (69%)
14,740 (67%)
12.6
20.5
9.7 / 8.4
3.66

LSN240HSV3
Match with LSU240HSV3 only

40 9/16 x 12 13/16 x 9 11/16


30.9
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
735~622~509~399
45~40~35~29
5/8 male
Yes
Yes
Yes

47 19/32 x 13 5/8 x 8 1/16


35.5
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
883~742~629~424
46~43~39~37
5/8 male
Yes
Yes
Yes

-10 ~ 48C (14 ~ 118F)


-20 ~ 24C (-4 ~ 75F)
1 / 208~230 / 60
25
19
10 ~ 98
50
3/8
5/8
R410A
63.5
.38
1 Rotary Inverter
122.4
34 1/4 x 31 1/2 x 12 19/32
45

-10 ~ 48C (14 ~ 118F)


-20 ~ 24C (-4 ~ 75F)
1 / 208~230 / 60
25
19
10 ~ 98
50
3/8
5/8
R410A
70.5
.38
1 Rotary Inverter
127.8
34 1/4 x 31 1/2 x 12 19/32
55

LSU120HSV4
Match with LSN240HSV3 only
22,000 / 27,600
22,498 (82%)
19,097 (69%)
18,424 (67%)
12.5
20
10.2 / 8.9
3.4

Warranty: 5 years parts, 10 years compressor


Optional Accessories:
PQSH1201 Base Pan Heater (LSU180HSV4 only)
PCRCUDT3 Wi-Fi Adapter for LG Smart AC
PREMTB10U programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
PRARS1 Auxiliary Heat Relay (requires PREMTB10U wired controller)
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

LSN180HSV4 will use a 1/4 & 1/2 lineset with any Multi F outdoor unit.
LSN180HSV4 will use a 3/8 & 5/8 lineset with LSU180HSV4.

PAG-HS8
PAG-HS2
PQCA0

Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx


All electrical wiring must comply with applicable local, provincial and national codes.

36

PAG-HS8
PAG-HS2
PQCA0

SINGLE ZONE

-20C operation

Gloss White
30,000 & 36,000 BTU
System
Indoor Model
Outdoor Model
Capacity1 (BTU/hr) Rated Cooling / Heating
Maximum Heating Output

At -8C
At -15C
At -20C

E.E.R.
S.E.E.R.
H.S.P.F
C.O.P.
Indoor
Dimension W x H x D (Inch)
Net Weight (Lbs)
Power Supply From Outdoor Unit ( / V /Hz)
Connecting Wire Outdoor To Indoor2:
Controller
Controller Operating Range

Cooling
Heating

Air Flow Rate (cfm) Max~Hi~Med~Low


Sound Pressure (dBA) Hi~Med~Low~Sleep
Condensate Connection OD (Inch)
Condensate Sensor Connection
Cooling-only Option
WLAN Smart Phone Control (PCRCUDT3 required separately)
Outdoor
Operation Range
Cooling (DB)
Heating (WB)
Power Supply ( / V /Hz)
MOP
MCA
Minimum ~ Maximum Lineset Length (Ft)
Maximum Lineset Elevation (Ft)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Refrigerant
Factory Charge (Oz) - Sufficient for 25' lineset
Charge Adjustment Over Precharge Length (Oz / Ft)
Compressor Number and Type
Net Weight (Lbs)
Dimension W x H x D (Inch)
Sound Pressure (dBA)

LS307HV3
30,000 BTU
LSN307HV3
LSU307HV3
30,000 / 32,000
26,420 (82%)
22,080 (69%)
21,440 (67%)
10
18
9.5
3.02

LS360HV3
36,000 BTU
LSN360HV3
LSU360HV3
33,000 / 35,200
28,864 (82%)
24,288 (69%)
23,584 (67%)
8.2
16.1
9.9
2.68

47 19/32 x 13 5/8 x 8 1/16


35.5
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
883~742~629~424
49~44~39~37
5/8
Yes
Yes
Yes

47 19/32 x 13 5/8 x 8 1/16


35.5
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
883~742~629~424
49~44~39~37
5/8
Yes
Yes
Yes

-10 ~ 48C (14 ~ 118F)


-20 ~ 24C (-4 ~ 75F)
1 / 208~230 / 60
30
19
10 ~ 98
50
3/8
5/8
R410A
70.5 ounces
.38
1 Rotary Inverter
127.8
34 1/4 x 31 1/2 x 12 19/32
55

-10 ~ 48C (14 ~ 118F)


-20 ~ 24C (-4 ~ 75F)
1 / 208~230 / 60
30
19
10 ~ 98
50
3/8
5/8
R410A
70.5 ounces
.38
1 Rotary Inverter
127.8
34 1/4 x 31 1/2 x 12 19/32
55

PAG-HS8
PAG-HS2
PQCA0

PAG-HS8
PAG-HS2
PQCA0

Warranty: 5 years parts, 10 years compressor


Optional Accessories:
PCRCUDT3 Wi-Fi Adapter for LG Smart AC
PREMTB10U programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
PRARS1 Auxiliary Heat Relay (requires PREMTB10U wired controller)
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx


All electrical wiring must comply with applicable local, provincial and national codes.

37

Gloss White
115V Mega
9,000 & 12,000 BTU
System
Energy Star

Indoor Model
Outdoor Model
Capacity1 (BTU/hr) Rated Cooling / Heating
E.E.R.
S.E.E.R.
H.S.P.F. (Region IV / V)
C.O.P.
Indoor
Dimension Inches W x H x D
Net Weight (Lbs)
Power Supply ( / V /Hz)
Connecting Wire Outdoor To Indoor2:
Controller
Controller Operating Range

Cooling
Heating

Air Flow Rate (cfm) Max~Hi~Med~Low


Sound Pressure (dBA) Hi~Med~Low~Sleep
Condensate Connection OD (Inch)
Condensate Sensor Connection
Cooling-only Option
WLAN Smart Phone Control (PCRCUDT3 required separately)
Outdoor
Operation Range
Cooling (DB)
Heating (WB)
Power Supply ( / V /Hz)
MOP
MCA
Minimum ~ Maximum Lineset Length (Ft)
Maximum Lineset Elevation (Ft)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Refrigerant
Factory Charge (Oz) - Sufficient for 25' lineset
Charge Adjustment Over Precharge Length (Oz / Ft)
Compressor Number and Type
Net Weight (Lbs)
Dimension W x H x D (Inch)
Sound Pressure (dBA)

LS090HXV
9,000 BTU

LS120HXV
12,000 BTU

LSN090HXV
LSU090HXV
8,500 / 10,900
12.01
17
9.0 / 7.8
3.63

LSN120HXV
LSU120HXV
12,000 / 13,000
10.5
17
9.0 / 7.8
3.5

34 27/32 x 11 1/4 x 9/32


22.5
1 / 115 / 60
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
335 ~ 272 ~ 212 ~ 124
38 ~ 33 ~ 23 ~ 19
5/8 male
Yes
No
No

34 27/32 x 11 1/4 x 9/32


22.5
1 / 115 / 60
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
335 ~ 272 ~ 212 ~ 124
38 ~ 33 ~ 23 ~ 19
5/8 male
Yes
No
No

-10 ~ 48C (14 ~ 118F)


-10 ~ 18C (14 ~ 65F)
1 / 115 / 60
20
13.5
10 ~ 50
23
1/4
3/8
R410A
31.7
.22
1 Rotary Inverter
66.1
28 1/4 x 19 1/32 x 9 1/16
47

-10 ~ 48C (14 ~ 118F)


-10 ~ 18C (14 ~ 65F)
1 / 115 / 60
20
13.5
10 ~ 50
23
1/4
3/8
R410A
31.7
.22
1 Rotary Inverter
66.1
28 1/4 x 19 1/32 x 9 1/16
47

Warranty: 5 years parts, 10 years compressor

Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx


All electrical wiring must comply with applicable local, provincial and national codes.

38

Gloss White
Long Lineset
Commercial Unit

SINGLE ZONE

-20C operation

24,000 - 36,000 BTU


System
Energy Star

Indoor Model
Outdoor Model
Capacity1 (BTU/hr) Rated Cooling / Heating
Maximum Heating Output

At -8C
At -15C
At -20C

E.E.R.
S.E.E.R.
H.S.P.F (Region V / IV)
C.O.P.
Indoor
Dimension W x H x D (Inch)
Net Weight (Lbs)
Power Supply From Outdoor Unit ( / V /Hz)
Connecting Wire Outdoor To Indoor2:
Controller
Controller Operating Range
Air Flow Rate (cfm) Max~Hi~Med~Low
Sound Pressure (dBA) Hi~Med~Low~Sleep
Condensate Connection OD (Inch)
Condensate Sensor Connection
Cooling-only Option
Sound Pressure (dBA)
WLAN Smart Phone Control
Outdoor
Operation Range

Cooling
Heating

LS240HLV
24,000 BTU

LS300HLV
30,000 BTU

LS360HLV
36,000 BTU

LSN240HLV
LSU240HLV
22,000 / 27,000
22,410 (83%)
18,900 (70%)
17,820 (66%)
12.5
21.5
11.0 / 9.6
3.32

LSN300HLV
LSU300HLV
30,000 / 32,000
26,560 (83%)
22,400 (70%)
21,120 (66%)
10
19
10 / 8.7
3.03

LSN360HLV
LSU360HLV
33,000 / 35,200
29,216 (83%)
24,640 (70%)
23,232 (66%)
8.18
17.5
10 / 8.7
2.69

46 7/8 x 13 5/8 x 10 7/16


39.7
1 / 208~230 / 60
4 x minimum 18# (ground included)
stranded, rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
953~848~706~530
49~44~40~37
5/8
Yes
Yes
55
No

46 7/8 x 13 5/8 x 10 7/16


39.7
1 / 208~230 / 60
4 x minimum 18# (ground included)
stranded, rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
953~848~706~530
49~44~40~37
5/8
Yes
Yes
55
No

46 7/8 x 13 5/8 x 10 7/16


39.7
1 / 208~230 / 60
4 x minimum 18# (ground included)
stranded, rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
953~848~706~530
49~44~40~37
5/8
Yes
Yes
55
No

-10 ~ 48C (14 ~ 118F)


-20 ~ 24C (-4 ~ 75F)
1 / 208~230 / 60
23
35
10 ~ 164
98
3/8
5/8
R410A
77.6 ounces
.38
1 Twin Rotary Inverter
124.6
34 1/4 x 31 1/2 x 12 5/8

-10 ~ 48C (14 ~ 118F)


-20 ~ 24C (-4 ~ 75F)
1 / 208~230 / 60
23
35
10 ~ 164
98
3/8
5/8
R410A
77.6 ounces
.38
1 Twin Rotary Inverter
124.6
34 1/4 x 31 1/2 x 12 5/8

PAG-HS8
PAG-HS2
PQCA0

PAG-HS8
PAG-HS2
PQCA0

Cooling (DB) -10 ~ 48C (14 ~ 118F)


Heating (WB) -20 ~ 24C (-4 ~ 75F)
Power Supply ( / V /Hz)
1 / 208~230 / 60
MOP
23
MCA
35
Minimum ~ Maximum Lineset Length (Ft)
10 ~ 164
Maximum Lineset Elevation (Ft)
98
Liquid Line Connection (Inch)
3/8
Gas Line Connection (Inch)
5/8
Refrigerant
R410A
Factory Charge (Oz) - Sufficient for 25' lineset
77.6 ounces
Charge Adjustment Over Precharge Length (Oz / Ft)
.38
Compressor Number and Type
1 Twin Rotary Inverter
Net Weight (Lbs)
124.6
Dimension W x H x D (Inch)
34 1/4 x 31 1/2 x 12 5/8
Warranty: 5 years parts, 10 years compressor
Optional Accessories:
PREMTB10U programmable wired controller
PZCWRG3 Group Control / Extension Wire
PDRYCB300 Third Party Thermostat Adapter Kit
PRARS1 Auxiliary Heat Relay (requires PREMTB10U wired controller)
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

PAG-HS8
PAG-HS2
PQCA0

Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx


All electrical wiring must comply with applicable local, provincial and national codes.

39

Ceiling Cassette
18,000 - 24,000 BTU

PT-UMC1 Grille Required as Accessory

System
Energy Star

Indoor Model
Outdoor Model3
Capacity1 (BTU/hr) Rated Cooling / Heating
At 0C
At -18C

E.E.R.
S.E.E.R.
H.S.P.F
Accessory Grille PT-UMC1 required, not included with indoor unit
Grille Dimensions W x H x D (Inch) (Not Included)
Grille Net Weight (Lbs)
Indoor
Unit Dimension W x H x D (Inch)
Unit Net Weight (Lbs)
Power Supply ( / V /Hz)
Connecting Wire Outdoor To Indoor2:
Controller
Controller Operating Range

WLAN Smart Phone Control


Air Flow Rate (cfm) Hi~Med~Low
Sound Pressure, Cooling (dBA) Hi~Med~Low
Condensate connection OD (Inch)
Built-in Condensate Pump
Condensate Pump Lift (inch)
Outdoor
Operation Range
Power Supply ( / V /Hz)
MOP
MCA
Minimum ~ Maximum Lineset Length (Ft)
Maximum Lineset Elevation (Ft)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Refrigerant
Factory Charge (Oz) - Sufficient for 25' lineset
Charge Adjustment Over Precharge Length (Oz / Ft)
Compressor Number and Type
Net Weight (Lbs)
Dimension W x H x D (Inch)
Sound Pressure (dBA)

Cooling
Heating

LC187HV
18,000 BTU

LC247HV
24,000 BTU

LCN187HV
LUU187HV
18,000 / 20,000
17,240
8,240
15
20
10.1

LCN247HV
LUU247HV
24,000 / 27,000
23,280
14,590
12.6
17
9.7

37 13/32 x 1 x 37 13/32
11

37 13/32 x 1 x 37 13/32
11

33 1/16 x 8 1/32 x 33 1/16


45.2
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded, rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No
565~494~424
38~36~34
1 1/4
Yes
31 1/2 from unit bottom

33 1/16 x 8 1/32 x 33 1/16


45.2
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No
600~530~459
38~36~34
1 1/4
Yes
31 1/2 from unit bottom

Cooling (DB) -15~48C (5~118F)


Heating (WB) -18~18C (0~64F)
1 / 208~230 / 60
31.6
18.1
10 ~ 164
100
3/8
5/8
R410A
70.5 ounces
.43
1 Twin Rotary Inverter
132.3
37 13/32 x 32 27/32 x 13
Cooling
48
Heating
52

-15~48C (5~118F)
-18~18C (0~64F)
1 / 208~230 / 60
31.6
18.1
10 ~ 164
100
3/8
5/8
R410A
70.5 ounces
.43
1 Twin Rotary Inverter
132.3
37 13/32 x 32 27/32 x 13
48
52

Warranty: 5 years parts, 7 years compressor


Optional Accessories:
PREMTB10U programmable wired controller
PZCWRG3 Group Control / Extension Wire
PRARH0 Auxiliary Heat Relay (requires PREMTB10U wired controller)
3rd Party Thermostat Kit PDRYCB300
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

PAG-HS6
PAG-HS7
PQCA0

PAG-HS6
PAG-HS7
PQCA0

Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx


All electrical wiring must comply with applicable local, provincial and national codes.
LUUxxxHV universal outdoor units are matched with both LHNxxxHV high-static horizontal air handler and LCNxxxHV ceiling cassette indoor units

40

Ceiling Cassette
PT-UMC1 Grille Required as Accessory

36,000 - 42,000 BTU


System
Energy Star

Indoor Model
Outdoor Model3
Capacity1 (BTU/hr) Rated Cooling / Heating
At 0C
At -18C

E.E.R.
S.E.E.R.
H.S.P.F
Accessory Grille PT-UMC1 required, not included with indoor unit
Grille Dimensions W x H x D (Inch) (Not Included)
Grille Net Weight (Lbs)
Indoor
Unit Dimension W x H x D (Inch)
Unit Net Weight (Lbs)
Power Supply ( / V /Hz)
Connecting Wire Outdoor To Indoor2:
Controller
Controller Operating Range

WLAN Smart Phone Control


Air Flow Rate (cfm) Hi~Med~Low
Sound Pressure, Cooling (dBA) Hi~Med~Low
Condensate connection OD (Inch)
Built-in Condensate Pump
Condensate Pump Lift (inch)
Outdoor
Operation Range
Power Supply ( / V /Hz)
MOP
MCA
Minimum ~ Maximum Lineset Length (Ft)
Maximum Lineset Elevation (Ft)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Refrigerant
Factory Charge (Oz) - Sufficient for 25' lineset
Charge Adjustment Over Precharge Length (Oz / Ft)
Compressor Number and Type
Net Weight (Lbs)
Dimension W x H x D (Inch)
Sound Pressure (dBA)

Cooling
Heating

LC367HV
36,000 BTU

LC427HV
42,000 BTU

LCN367HV
LUU367HV
36,000 / 40,000
34,490
18,370
13.5
19
9.5

LCN427HV
LUU427HV
42,000 / 47,000
40,530
20,170
10.3
17
8.6

37 13/32 x 1 x 37 13/32
11

37 13/32 x 1 x 37 13/32
11

33 1/16 x 11 11/32 x 33 1/16


54.2
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded, rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No
1,060~989~918
46~44~43
1 1/4
Yes
31 1/2 from unit bottom

33 1/16 x 11 11/32 x 33 1/16


54.2
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
Wireless LCD Remote
18 ~ 30C (64 ~ 86F)
16 ~ 30C (61 ~ 86F)
No
1,060~989~918
46~44~43
1 1/4
Yes
31 1/2 from unit bottom

Cooling (DB) -15~48C (5~118F)


Heating (WB) -18~18C (0~64F)
1 / 208~230 / 60
43.1
24.7
10 ~ 246
100
3/8
5/8
R410A
119.9 ounces
.43
1 Twin Rotary Inverter
202.8
37 13/32 54 11/32 x 13
Cooling
52
Heating
54

-15~48C (5~118F)
-18~18C (0~64F)
1 / 208~230 / 60
41.6
24.1
10 ~ 246
100
3/8
5/8
R410A
119.9 ounces
.43
1 Twin Rotary Inverter
202.8
37 13/32 54 11/32 x 13
52
54

Warranty: 5 years parts, 7 years compressor


Optional Accessories:
PREMTB10U programmable wired controller
PZCWRG3 Group Control / Extension Wire
PRARH0 Auxiliary Heat Relay (requires PREMTB10U wired controller)
3rd Party Thermostat Kit PDRYCB300
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

PAG-HS5
PAG-HS4
PQCA0

PAG-HS5
PAG-HS4
PQCA0

Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx


All electrical wiring must comply with applicable local, provincial and national codes.
LUUxxxHV universal outdoor units are matched with both LHNxxxHV high-static horizontal air handler and LCNxxxHV ceiling cassette indoor units

41

High-Static
Horizontal Air Handler
LUU247HV

24,000 & 36,000 BTU


System
Energy Star

Indoor Model
Outdoor Model3
Capacity1 (BTU/hr) Rated Cooling / Heating
At 0C
At -18C
E.E.R.
S.E.E.R.
H.S.P.F
Indoor
Dimension W x H x D (Inch)
Net Weight (Lbs)
Power Supply From Outdoor Unit ( / V /Hz)
Connecting Wire Outdoor To Indoor2:
Controller
Controller Operating Range
WLAN Smart Phone Control
Air Flow Rate (cfm)
Static Pressure (Inches Water)
Sound Pressure, Cooling (dBA)

Cooling
Heating
High (Factory Setting)
Medium
Low

Condensate Connection OD (Inch)


Built-in Condensate Pump
Built-in Condensate Sensor
Condensate Pump Lift (inch)
Outdoor
Operation Range
Power Supply ( / V /Hz)
MOP
MCA
Minimum ~ Maximum Lineset Length (Ft)
Maximum Lineset Elevation (Ft)
Liquid Line Connection (Inch)
Gas Line Connection (Inch)
Refrigerant
Factory Charge (Oz) - Sufficient for 25' lineset
Charge Adjustment Over Precharge Length (Oz / Ft)
Compressor Number and Type
Net Weight (Lbs)
Dimension W x H x D (Inch)
Sound Pressure (dBA)

High
Medium
Low

LH247HV
24,000 BTU

LH367HV
36,000 BTU

LHN247HV
LUU247HV
24,000 / 27,000
24,650
19,400
12
17
10

LHN367HV
LUU367HV
36,000 / 40,000
36,520
28,740
12.1
17.6
9.2

46 17/32 x 11 23/32 x 17 23/32


72.8
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
Wired Non-Programmable
18 ~ 30C (64 ~ 86F)
No
16 ~ 30C (61 ~ 86F)
688
618
530
.39
38
36
35
1 1/4
Yes
Yes
27 9/16 from unit bottom

48 7/16 x 14 31/32 x 23 7/32


124.6
1 / 208~230 / 60
4 x minimum 18# (ground included) stranded,
rated at 300V minimum
Wired Non-Programmable
18 ~ 30C (64 ~ 86F)
No
16 ~ 30C (61 ~ 86F)
1130
953
706
.39
39
38
37
1 1/4
Yes
Yes
27 9/16 from unit bottom

Cooling (DB) -15 ~ 48C (5 ~ 118F)


Heating (WB) -18 ~ 18C (0 ~ 64F)
1 / 208~230 / 60
31.6
18.1
10 ~ 164
100
3/8
5/8
R410A
70.5 ounces
.43
1 Twin Rotary Inverter
132.3
37 13/32 x 32 27/32 x 13
Cooling
48
Heating
52

-15 ~ 48C (5 ~ 118F)


-18 ~ 18C (0 ~ 64F)
1 / 208~230 / 60
43.1
24.7
10 ~ 246
100
3/8
5/8
R410A
119.9 ounces
.43
1 Twin Rotary Inverter
202.8
37 13/32 54 11/32 13
52
54

Warranty: 5 years parts, 7 years compressor


Optional Accessories:
PREMTB10U programmable wired controller
PZCWRG3 Group Control / Extension Wire
PRARH0 Auxiliary Heat Relay (requires PREMTB10U wired controller)
3rd Party Thermostat Kit PDRYCB300
Kit For Low Ambient Cooling Operation
Front Wind Guard
Rear / Side Wind Guard
Control Adapter

PAG-HS6
PAG-HS7
PQCA0

PAG-HS5
PAG-HS4
PQCA0

Refer to the Engineering Manual for capacity charts at http://LGcomfort.ca/en/engineering-resources.aspx


All electrical wiring must comply with applicable local, provincial and national codes.
LUUxxxHV universal outdoor units are matched with both LHNxxxHV high-static horizontal air handler and LCNxxxHV ceiling cassette indoor units

42

LUU367HV

NOTES

43

Packaged Terminal Air Conditioners


7,000-15,000 BTU/h
Ultra-quiet operation is the hallmark of LGs line of PTAC products. Low decibel levels and an outstanding soundprevention rating make this your best choice for a quiet environment. And with efficiency ratings up to 13 EER
and 3.6 COP, these units are also your energy efficient choice.
Other features include standard connections for remote thermostat and front desk controls. Gold Fin coil
coating protects the coil from the corrosive effects of outside air and extends the operating life of PTAC models.
And the industry standard 42" size makes installation easy and economical.

Available in cooling +
electric heat and heat pump +
electric heat models in
7, 9, 12 and 15,000 BTU sizes.

LG PTAC
SYSTEMS

ULTRA
QUIET
*Tested by Independent 3rd Party
(Cerami & Associates Inc., Jan. 2007)

44

Digital Control Panel

Packaged Terminal Air Conditioners


PTAC Features & Benefits
Ventilation Filter
Polymeric mesh filter allows
filtered outside air into the living
space. Suitable for Hospitality,
Health Care and Assisted Living
applications.

Separate Indoor & Outdoor


BLDC Motors*
Individual indoor & outdoor BLDC
(Brushless Digitally-Controlled)
motors allows the lowest sound
rating in the industry while also
promoting the proper airflow and the
highest level of energy efficiency.

LG HIGH-EER PTAC:

High-efficiency BLDC (Brushless


Digitally-Controlled) indoor & outdoor fan motors.
Larger, higher-efficiency indoor & outdoor coils.
Reengineered compressor for higher efficiency

Digital Control Display Includes:


Temperature Display on Unit
Precise and easy to use.
ADAcompliant.
Cooling, Heating and Fan Modes
One unit for all seasons.
Auto Restart
Automatically restarts to programmed
setting when the electricity comes on
after a power failure.

Emergency Heat

Room Freeze Protection

(Heat pump models only) Bypasses


compressor operation and activates
the ceramic or coil heater during periods of extreme cold. Promotes high
level of guest comfort.

Electronic temperature controls


constantly monitor and
maintain indoor temperature
to prevent freezing while
unoccupied and turned off.

1-year full system limited warranty, parts and labor. Limited warranty on unit for years 2-5: parts only, exclusive of the refrigeration system.
Limited warranty on sealed refrigeration system: 5 years, parts and labor.

45

Defrost Control

(Heat pump models only)


Shuts down the indoor fan
to prevent cold air from
being blown into the room.
Also removes frost from
outdoor coil when the
outdoor temperature is low.

Sensors
4 Sensors provide highly
efficient operation and
maximize guest comfort.

Pressure Control
Protects guests by shutting down
the compressor on abnormal high
pressure condition.

High-Efficiency Rotary Compressor


Re-engineered for 2013, it provides energy
efficiency and maintenance-free operation.

Gold Fin Anti-Corrosion


Protects the unit from the corrosive effects of
outside air and extends the operating life of PTAC
models. LGs patented process is standard on ALL
LG PTAC models.

Power Cord
Dip Switches
Increase flexibility and energy savings
for operators with min-max temperature
options and internal/remote thermostat.

46

Included in 15A
configuration for
7,000BTU models and
20A configuration for
9, 12 and 15,000BTU
models (up to 3.5kW
heater only)

Ceramic Heater
Uniform, stable and safe heating platform.

Packaged Terminal Air Conditioners


7,000-15,000 BTU/h Digital Control (230/208V)
LG PTAC
SYSTEMS

ULTRA
QUIET
LP073CD2B (H/C Model)

LP073HD2B (Heat Pump Model)

LP093CD3B (H/C Model)

LP093HD3B (Heat Pump Model)

LP123CD3B (H/C Model)

LP123HD3B (Heat Pump Model)

LP153CD3B (H/C Model)

LP153HD3B (Heat Pump Model)

*Tested by Independent 3rd Party


(Cerami & Associates Inc., Jan. 2007)

FEATURES:
Gold Fin anti-corrosion treatment
Cooling mode
Heating mode
Fan mode
Auto restart
Digital temperature control

Front desk control connection


Dip switch settings
Evaporator frost control
Temperature display on unit
Freeze room protection
Pressure control

Ceramic heater
System Includes:
Wall unit
Installation manual
UL #: SA13362
* Specification can be changed without notification

System Model #

LP073CD2B

LP093CD3B

LP123CD3B

LP153CD3B

LP073HD2B

LP093HD3B

LP123HD3B

LP153HD3B

Control Type
Performance
Capacity (BTU/h)
208 / 230V
Refrigerant
EER
Max. Air Circulation (CFM)
Fan Speeds
(Cooling/Heating/Fan)
Dehumidification (pts/hr)
Indoor dB(A)*
Outdoor dB(A)*
STC
Electrical
Rated Voltage
Electric Heater (kW)
Circuit Breaker (A)
Dimension
W x H x D (inches)
Weight (lbs.)
Thermostat Range
Cooling/Heating (F)**

Digital

Digital

Digital

Digital

Digital

Digital

Digital

Digital

7,100/7,300

9,300/9,500

12,000/12,200

14,900/15,100

7,100/7,300

9,300/9,500

12,000/12,200

14,700/14,500

8,200 / 8,600

10,500 / 11,900

10,500 / 11,900

10,500 / 11,900

8,200/8,600

10,500 / 11,900

10,500 / 11,900

12,100/11,900

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

13.3

12.7

11.9

11.2

13.3

12.9

11.9

9.4

225/270

225/270

353/420

353/420

225/270

225/270

353/420

353/420

2/2/2

2/2/2

2/2/2

2/2/2

2/2/2

2/2/2

2/2/2

2/2/2

1.7

2.6

3.0

4.3

1.7

2.6

3.0

4.3

45/43

46/44

50/48

51/49

45/43

46/44

50/48

51 / 49

61

61

63

64

61

61

63

64

30

30

30

30

30

30

30

30

230/208-60-1

230/208-60-1

230/208-60-1

230/208-60-1

230/208-60-1

230/208-60-1

230/208-60-1

230/208-60-1

2.5

3.5

3.5

3.5

2.5

3.5

3.5

3.5

15

20

20

20

15

20

20

20

42 x 16 x 19 7/8

42 x 16 x 19 7/8

42 x 16 x 19 7/8

42 x 16 x 19 7/8

42 x 16 x 19 7/8

42 x 16 x 19 7/8

42 x 16 x 19 7/8

42 x 16 x 19 7/8

95

95

99

115

95

106

106

115

54-86/54-86

54-86/54-86

54-86/54-86

54-86/54-86

54-86/54-86

54-86/54-86

54-86/54-86

54-86/54-86

*LG verified sound rating


**Adjustable by temperature limiting with DIP switches on the unit.
1-year full system limited warranty, parts and labor. Limited warranty on unit for years 2-5: parts only, exclusive of the refrigeration system.
Limited warranty on sealed refrigeration system: 5 years, parts and labor.

47

Packaged Terminal Air Conditioners


Accessories
Description

Model #

Description

Model #

Description

Model #

42 Wall Sleeve

AYSVB01A

Sub Base 30A 230/208V

AYSB2101A

Control Panel Key Lock

AYCP101

Architecture Grille - Aluminum

AYAGALA01A

Condensate Drain Kit

AYDR101

Built-in Control Cover Kit - 10 Pack

AYRE110

Sub Base 20A 230/208V

AYSB1101A

Leveling Legs

AYLL101

Replacement Filter - 10 Pack

AYFT110

42 Wall Sleeve
AYSVB01A

EMS/Front Desk Control Connection Kit


AYFD101

Wireless PYRCUCC1HB
24V PTAC Thermostat

Hardwire Kit
AYHW101

Leveling Legs
AYLL101

Replacement Filter 10-Pack


AYFT110

Architecture Grille - Aluminum


AYAGALA01A

24V Wired PYRCUCA0B


PTAC Wired Thermostat

Condensate Drain Kit


AYDR101

Thermostat Wire Connection Kit


AYWH101
(ships with new units)

Installation Quick Reference

Trim Molding
(if desired)

Caulk
(4 sides)

16
Room Side

16

13 3/4

Outside

13 3/4

Box and
Receptacle
Note: pitch to outside

48

42

NOTES

49

NOTES

50

NOTES

51

LG Electronics Canada, Inc.


20 Norelco Drive, North York, ON M9L 2X6