You are on page 1of 7

measuring

Magnetic Inductive
Flowmeter

monitoring

for conductive fluids

analysing

DMH

OO

Measuring range:
0.0540376 m3/h

Accuracy: 0.3% of reading


0.01% x Qmax

OO

pmax: PN40; tmax: -20...+150C

OO

 onnection: Flange DN 10...1200,


C
ANSI "...48"

S5

OO

Lining material: Hard rubber,


soft rubber, PTFE / PFA

OO

Outputs: Analogue with HART,


pulses and status
OO

1/05-2015

KOBOLD companies worldwide:

ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA,


CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY,
MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA,
SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM

KOBOLD Messring GmbH


Nordring 22-24
D-65719 Hofheim/Ts.
Head Office:
+49(0)6192 299-0
+49(0)6192 23398
info.de@kobold.com
www.kobold.com
1

Magnetic Inductive Flowmeter Model DMH

Description
The KOBOLD DMH flowmeter is used to measure and monitor the volume flow rate of fluids, pulps, pastes and other
electrically conductive materials, without loss of pressure.
When an electrically conductive medium passes through a
directional magnetic field, a voltage is induced in accordance
with Faradays Law of Induction.
The size of this measurement voltage is proportional to the
mean rate of flow and consequently also to the volume flow
rate.
A flowmeter consists of a sensor that picks up the measuring
signal generated from the induced voltage, and a transducer that converts this signal into a standardised output signal
(4-20 mA or pulses). The measurement transducer can be
affixed to the sensor or mounted separately.
Pressure, temperature, density and viscosity do not affect
the volume measurement. Solid fractions and gas bubbles
should be avoided.
The significant properties exhibited by DMH include:
OO Great choice of linings
OO Stainless

steel, Hastelloy, tantalum or platinum


electrodes

OO Wide
OO Can

variety of process connections

be used in rough ambient conditions

Fields of application
alkalis

Technical data
Adjustable measuring
range terminal values: 0.5...10 m /s
Minimum conductivity: 5 S /cm

(for fluids in general)

20 S/cm

(demineralised water)
Accuracy:
0.3% of read. 0.01% x Qmax
Repeat accuracy:
0.15% of read. 0.005% x Qmax

(reference conditions: water,

measured medium

temperature of 22C 4K,

ambient temperature 22C 2K,

inlet path 10 x DN,

outlet path 5 x DN,

Qmax at 10 m/s)
Process temperature: 0...+80C

(hard rubber, soft rubber)

-20...+150C (PTFE); PFA
Ambient temperature: -20...+60C,

depending on process temperature
Rated pressure: PN40, (40 bar)
DN15...300 ("-12")
PN16, (16 bar)
DN10...600 ("-24")
PN10, (10 bar) DN200...600

PN6, (6 bar) DN700...1200

higher pressures on request
Sensor materials
Linings: Hard rubber, soft rubber, PTFE,
PFA
Electrodes:
Stainless steel, Hastelloy C4,

tantalum, platinum, earth ring and

other materials on request
Housing:
Enamelled steel (DMH-1,DMH-2,

DMH-5)

stainless steel (DMH-6)
Process connection:
Steel or stainless steel 1.4301

flange EN1092 and ASME B16.5,

wafer version, foodstuff,

screw seal DIN11851, Tri-Clamp,

other connections on request
Nominal sizes:
DN10...DN1200

other nominal sizes on request
Protection type:
IP67, IP68

OO Acids,

OO Pastes

water, waste water etc.

www.kobold.com

No responsibility taken for errors;


subject to change without prior notice.

1/05-2015

OO Drinking

Magnetic Inductive Flowmeter Model DMH

1/05-2015

Technical data (continued)


Transducer UMF2(B)
Assembly type:
Compact or separate
Housing:
Enamelled die-cast aluminium
Power supply:
115 VAC, 50/60 Hz, 10 VA

230 VAC, 50/60 Hz, 10 VA

24 VDC 10W
Outputs
Analogue: 1 x 0(4)-20 mA, active, galvanically
isolated
Pulse output: Passive, galvanically isolated
24 V, 60 mA
Status: Passive, galvanically isolated
24 V, 60 mA
Ambient temperature: -20+60 C,

depending on process temperature

for compact version
Protection type:
IP68 (EN60529)
Communication: HART
Diagnosis functions:
Empty pipe recognition,

flushing flow monitoring
Electromagnetic
compatibility: EMV directive 2004/108/EG

No responsibility taken for errors;


subject to change without prior notice.

www.kobold.com

Magnetic Inductive Flowmeter Model DMH

Measuring range
Flange DN
10*
10*
10*
15
20
25
32
40
50
65
65
80
80
100
125
150
200
250
300
300
350
400
450
500
600
700
800
900
1000
1200
ASME
*
*
*

1
11
1
2
2
3
4
5
6
8
10
12
14
16
18
20
24

Pressure rating PN
16
16
16
40
40
40
40
40
40
16
40
16
40
16
16/40
16/40
10/16/40
10/40
16/40
10
10/16
10/16
10/16
10/16
10/16
6
6
6
6
6
lbs
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150

Min. measuring range [m/h]


0.05
0.09
0.14
0.32
0.41
0.88
1.45
1.94
3.12
5.61
5.61
8.17
7.74
14.42
22.80
33.96
59.99
95.57
134.98
136.74
164.39
216.13
273.70
340.82
493.78
676.98
891.26
1127.37
1399.61
2022.20

Max. measuring range [m/h]


1.0
1.8
2.8
6.3
8.1
17.6
28.9
38.7
62.4
112
112
163
155
288
456
671
1188
1897
2682
2717
3269
4301
5449
6789
9842
13500
17780
22497
27936
40376

0.05
0.09
0.14
0.32
0.41
0.88
1.45
1.94
3.12
5.61
8.17
13.86
22.80
33.96
59.99
95.57
136.74
164.39
216.13
273.70
340.82
493.78

1.0
1.8
2.8
6.3
8.1
17.6
28.9
38.7
62.4
112
163
288
456
671
1188
1897
2717
3269
4301
5449
6789
9842

www.kobold.com

No responsibility taken for errors;


subject to change without prior notice.

1/05-2015

* Unit with PFA-lining, with 6, 8 and 10 mm tube

Magnetic Inductive Flowmeter Model DMH

Order Details (Example: DMH-1 A15 H 1 0 A 1 0)


Model/
flangematerial

Process connection1)
(flange acc. to
EN 1092-1 Form B1)
A065) = DN10/6 mm,
DMH-2 =
PN16
stainless
A085) = DN10/8 mm,
steel
PN16
1.4301
A105) = DN10/10 mm,
PN16
A153) = DN15, PN40
A20 = DN20, PN40
A25 = DN25, PN40
A32 = DN32, PN40
A40 = DN40, PN40
A50 = DN50, PN40
C65 = DN65, PN16
A65 = DN65, PN40
A80 = DN80, PN40
C1H = DN100, PN16
A1H = DN100, PN40
C1Z = DN125, PN16
A1Z = DN125, PN40
DMH-1=
C80 = DN80, PN16
enamelled
C1F = DN150, PN16
steel
A1F = DN150, PN40
D2H = DN200, PN10
DMH-2 =
C2H = DN200, PN16
stainless
A2H = DN200, PN40
steel
D2F = DN250, PN10
1.4301
A2F = DN250, PN40
D3H = DN300, PN10
DMH-52)=
C3H = DN300, PN16
wafer
A3H = DN300, PN40
version
A3F = DN350, PN10
C3F = DN350, PN16
D4H = DN400, PN10
C4H = DN400, PN16
D4F = DN450, PN10
D5H = DN500, PN10
C5H = DN500, PN16
D6H = DN600, PN10
C6H = DN600, PN16
E7H = DN700, PN6
E8H = DN800, PN6
E9H = DN900, PN6
ET0 = DN1000, PN6
ET2 = DN1200, PN6
H4)15 = DN15
H4)20 = DN20
H4)25 = DN25
DMH-63) = H4)32 = DN32
H4)40 = DN40
food
connection H4)50 = DN50
H4)65 = DN65
H4)80 = DN80
H4)1H = DN100

Lining

Measuring
electrode
material9)

Earth
electrode
material9)

Versions/
cable lengths

Electronics

Power supply/
cable entry
point

A = compact,
IP67
B ... H, IP 67
B = separate
version/2.5 m
C = separate
version/5 m
D = separate
version/10 m
E = separate
version/15 m

H6) = hard
rubber
W6) = soft
rubber
T7) = PTFE/
PFA

F = separate
08) = without
version/ 20 m 1 = UMF2(B)1 = stainless
electronics
1 = stainless G = separate
steel
with control
steel
version/ 30 m
unit, without
3 = HastelHART
H = separate
loy C4 3 = Hastelloy C4
version/ 50 m 2 = UMF2(B)4 = Titan
electronics
4 = Titan
K ... R, IP 68
5 = tantalum
with control
5 = tantalum K = separate
unit, with
7 = platinum
version/2.5 m
7 = platinum
HART
L = separate
version/5 m

0 = 230 VAC
M20x1.5
4 = 115 VAC
M20x1.5
3 = 24 VDC
M20x1.5
5 = 230 VAC
" NPT
6 = 115 VAC
" NPT
8 = 24 VDC
" NPT

M = separate
version/10 m
N = separate
version/15 m
P = separate
version/ 20 m
Q = separate
version/ 30 m
R = separate
version/ 50 m

ASME-flange class 150: code Lxx, ASME-flange class 300: code Mxx (up to 1 / DN 40), ANSI flange not available for sizes DN700, other process
connections on request
2)
Wafer version only for nominal width DN20200; standard flange rating PN40 from DN20...DN40 and PN16 from DN50...DN200
3)
Only valid with PTFE coating
4)
For Tri-Clamp connection replace H with T
5)
Only with PFA and 3 x HC4 electrode
6)
Only available with stainless steel electrode and stainless steel grounding electrode 11
7)
Standard with electrode material and grounding electrode material 33. Not with stainless steel electrode
8)
Only for PTFE liner and electrode material option 4, 5, and 7
9)
Measuring electrode material and grounding electrode material should be identical

1/05-2015

1)

No responsibility taken for errors;


subject to change without prior notice.

www.kobold.com

Magnetic Inductive Flowmeter Model DMH

Dimensions [mm]
Transducer UMF2(B)

Connection box for sensor, separate version


205

115

75

80

158

57

108

M 20 x1,5

DN

Sensor, flange connection

DN

PN

ASME

D
[mm]

D
ANSI

d
[mm]

A
[mm]

L
[mm]

I
[mm]

Weight*
[kg]

10/6
10/8
10
15
20
25
32
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
800
900
1000
1200

40
40
40
40
40
40
40
40
40
16/40
16/40
16/40
16/40
16/40
10/16/40
10/40
10/16/40
10/16
10/16
10/16
10/16
10/16
6
6
6
6
6

"
"
"
"
"
1"
1"
1"
2"
2"
3"
4"
5"
6"
8"
10"
12"
14"
16"
18"
20"
24"
28"
32"
36"
40"
48"

90
90
90
95
105
115
140
150
165
185
200
220
250
285
340
395
445
505
565
615
670
780
895
1015
1115
1230
1405

88.9
88.9
88.9
88.9
98.4
107.9
117.5
127
152.4
177.8
190.5
228.6
254
279.4
342.9
406.4
482.6
533.4
596.9
635
698.5
812.8
927.1
1060
1075
1230
1405

77
77
77
62
62
72
82
92
107
127
142
162
192
218
274
370
420
480
530
on request
640
760
880
960
1040
1140
1340

164
164
164
164
170
180
199
209
223
244
260
280
310
340
398
480
535
584
642
on request
752
870
990
1100
1185
1290
1510

230
230
230
200
200
200
200
200
200
200
200
250
250
300
350
450
500
550
600
on request
600
600
700
800
800
800
1200

100
100
100
66
66
96
96
96
96
96
96
96
126
126
211
211
320
320
320
on request
320
320
420
420
520
520
520

3
3
3
3
3
3
4
4
6
9
14
16
19
25
41
54
77
92
116
on request
167
315
on request
427
on request
500
680

* Weights of the sensors are only approximate values, including the weight of the electronics approx. 2.4 kg
6

www.kobold.com

No responsibility taken for errors;


subject to change without prior notice.

1/05-2015

Magnetic Inductive Flowmeter Model DMH

DN

Dimensions (continuation)
Sensor, wafer flange

DN

PN

D
[mm]

A
[mm]

L
[mm]

Weight*
[kg]

20

40

62

25

40

72

145

74

1.5

158

104

32

40

82

168

104

40

40

92

179

104

50

40

107

192

104

65

40

127

212

104

80

40

142

227

104

100

16

162

247

104

125

16

192

277

134

150

16

218

303

134

200

16

274

359

219

10

DN

* Weights of the sensors are only approximate values, including the weight of
the electronics approx. 2.4 kg

Food connection acc. to DIN 11851

15

74

144

170

20

74

144

170

25

74

144

225

32

84

154

225

40

94

164

225

50

104

174

225

65

129

199

280

80

140

210

280

100

156

226

280

DN

DN
PN10

DN

Connection Tri-Clamp (ISO)

DN

DN
PN10

L
(ISO mm)

L
(ISO Inch)

"

74

144

[mm]
145

[mm]
137

"

74

144

145

137

1"

74

144

145

137

1"

94

164

145

137

2"

104

174

145

137

2"

129

199

200

192

3"

142

227

200

4"

162

247

200

1/05-2015

No responsibility taken for errors;


subject to change without prior notice.

www.kobold.com

You might also like