You are on page 1of 49

ZXWR RNC

Radio Network Controller

Initial Configuration Guide


Version: V3.13.10.15

ZTE CORPORATION
No. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://support.zte.com.cn
E-mail: 800@zte.com.cn

LEGAL INFORMATION
Copyright 2015 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited.

Additionally, the contents of this document are protected by

contractual confidentiality obligations.


All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided as is, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit the ZTE technical support website http://support.zte.com.cn to inquire for related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History
Revision No.

Revision Date

Revision Reason

R1.0

2014-07-28

The content has been updated (V3.13.10.15)

Serial Number: SJ-20140527134425-012


Publishing Date: 2014-07-28 (R1.0)

SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Contents
About This Manual ......................................................................................... I
Chapter 1 Initial Configuration Overview ................................................. 1-1
Chapter 2 Common Resources Configuration ........................................ 2-1
2.1 Common Resources Configuration Flow .............................................................. 2-1
2.2 Creating a Subnetwork ....................................................................................... 2-1
2.3 Creating a Managed Element.............................................................................. 2-2

Chapter 3 Hardware Configuration ........................................................... 3-1


3.1 Hardware Configuration Flow .............................................................................. 3-1
3.2 Adding a Rack ................................................................................................... 3-1
3.3 Adding Shelves .................................................................................................. 3-2
3.4 Adding Boards ................................................................................................... 3-4
3.5 Creating a PLMN Group ..................................................................................... 3-5
3.6 Creating a local PLMN Group.............................................................................. 3-6

Chapter 4 Transmission Configuration (ATM Bearer)............................. 4-1


4.1 Transmission Configuration (ATM Bearer) Flow .................................................... 4-1
4.2 Creating a Local AAL2 Office .............................................................................. 4-1
4.3 Creating an Adjacent AAL2 Office ....................................................................... 4-2
4.4 Creating an IMA Group ....................................................................................... 4-3
4.5 Creating IMA Links ............................................................................................. 4-3
4.6 Creating an AAL2 Route ..................................................................................... 4-4
4.7 Creating an MTP3 Route .................................................................................... 4-5
4.8 Creating an MTP3 Route Set .............................................................................. 4-6

Chapter 5 Transmission Configuration (IP Bearer) ................................. 5-1


5.1 Transmission Configuration (IP Bearer) Flow ....................................................... 5-1
5.2 Creating an Ethernet Interface ............................................................................ 5-1
5.3 Creating an IPv4 Ethernet Interface ..................................................................... 5-2
5.4 Creating a Static Route....................................................................................... 5-3
5.5 Creating an Association ...................................................................................... 5-4
5.6 Creating an ASP ................................................................................................ 5-5
5.7 Creating an AS................................................................................................... 5-6
5.8 Creating an M3UA Route .................................................................................... 5-7
5.9 Creating an M3UA Route Set .............................................................................. 5-7

I
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 6 Logical Links Configuration .................................................... 6-1


6.1 Logical Links Configuration Flow ......................................................................... 6-1
6.2 Creating a UMTS Logical Function Configuration ................................................. 6-1
6.3 Creating a Near End Signalling Point ................................................................... 6-2
6.4 Creating an Adjacent Office Information............................................................... 6-3
6.5 Creating an Iub Link ........................................................................................... 6-4
6.6 Creating an Iucs Link.......................................................................................... 6-5
6.7 Creating an Iups Link.......................................................................................... 6-6
6.8 Creating an Iur Link ............................................................................................ 6-7

Chapter 7 Configuration Check and Synchronization ............................ 7-1


7.1 Synchronizing All Data........................................................................................ 7-1
7.2 Synchronizing Modified Data............................................................................... 7-2

Figures............................................................................................................. I
Glossary ........................................................................................................ III

II
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

About This Manual


Purpose
This manual provides instructions for the initial configuration of the ZXWR RNC.
For parameter settings in the initial configurations, refer to the actual data planning and
configuration solution.

Intended Audience
This manual is intended for:
l
l

Debugging engineers
Commissioning supervisors

What Is in This Manual


This manual contains the following chapters:
Chapter

Summary

1, Initial Configuration Overview

Provides the definition, flow, and prerequisites of data


configurations.

2, Common Resources Configuration

Describes how to configure common resources.

3, Hardware Configuration

Describes how to configure hardware.

4, Transmission Configuration (ATM

Describes how to configure transmission over Asynchronous

Bearer)

Transfer Mode (ATM).

5, Transmission Configuration (IP

Describes how to configure transmission over IP.

Bearer)
6, Logical Links Configuration

Describes how to configure logical links for connectivity to


adjacent offices.

7, Configuration Check and

Describes how to perform all data and modified data

Synchronization

synchronizations.

Conventions
This manual uses the following typographical conventions:
Typeface

Meaning
Note: provides additional information about a certain topic.

I
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

This page intentionally left blank.

II
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 1

Initial Configuration
Overview
Definition
Initial configuration refers to the process during which necessary parameters of the
ZXWR RNC are set on the client Graphical User Interface (GUI) of the Network Element
Management System (EMS), to enable the ZXWR RNC to implement basic services.

Initial Configurations Flow


For the initial configuration flow, see Figure 1-1.
Figure 1-1 Initial Configurations Flow

Prerequisites
For all operations subsequent to this section, the following prerequisites are presumed to
have been met:
l
l
l

The EMS server and the Operation & Maintenance Module (OMM) server are
operating properly, and can communicate with the ZXWR RNC properly.
The EMS client is started and successfully connected to the EMS server.
The permissions for initial configurations have been acquired.
1-1

SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

The Configuration Management tab is open on the client GUI.

1-2
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 2

Common Resources
Configuration
Table of Contents
Common Resources Configuration Flow ....................................................................2-1
Creating a Subnetwork ...............................................................................................2-1
Creating a Managed Element .....................................................................................2-2

2.1 Common Resources Configuration Flow


The configuration flow of common resources is as follows:
1. Creating a Subnetwork
2. Creating a Managed Element

2.2 Creating a Subnetwork


The following procedure describes how to create a subnetwork.

Steps
1. In the left pane of the Configuration Management tab, right-click the root node in the
NE tree, and then click Create Subnetwork. The SubNetwork sub-tab is displayed
in the right pane, see Figure 2-1.
Figure 2-1 Subnetwork Sub-tab

2. Set parameters as required.


3. Click

End of Steps

2-1
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

2.3 Creating a Managed Element


The following procedure describes how to create a managed element.

Steps
1. In the upper left pane of the Configuration Management tab, right-click the
previously-created subnetwork in the NE tree, and then click Create Managed
Element. The Element sub-tab is displayed in the right pane, see Figure 2-2.

Figure 2-2 Element Sub-tab

2. Set parameters as required.


3. Click . The created element is displayed under the subnetwork node in the NE
tree. A default configuration set (Modify Area) is available under the managed
element node. Users can click the Modify Area node to display the corresponding
configuration tree in the lower left pane, see Figure 2-3.

2-2
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 2 Common Resources Configuration

Figure 2-3 Managed Element Configuration Tree

End of Steps

2-3
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

This page intentionally left blank.

2-4
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 3

Hardware Configuration
Table of Contents
Hardware Configuration Flow .....................................................................................3-1
Adding a Rack............................................................................................................3-1
Adding Shelves ..........................................................................................................3-2
Adding Boards............................................................................................................3-4
Creating a PLMN Group .............................................................................................3-5
Creating a local PLMN Group.....................................................................................3-6

3.1 Hardware Configuration Flow


The hardware configuration flow is as follows:
1.
2.
3.
4.
5.

Adding a rack
Adding shelves
Adding boards
Creating a PLMN Group
Creating a local PLMN Group

3.2 Adding a Rack


The following procedure describes how to add a rack.

Steps
1. In the lower left pane of the Configuration Management tab, expand the Equipment
node in the configuration tree.
2. Double-click the Rack node. The Rack-List sub-tab is displayed in the right pane, see
Figure 3-1.
Figure 3-1 Rack-Table Mode Sub-tab

3. Click

. The Rack sub-tab is displayed, see Figure 3-2.

3-1
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

Figure 3-2 Rack Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the Rack sub-tab.


End of Steps

3.3 Adding Shelves


The following procedure describes how to add necessary shelves in a rack.

Note:
A rack only has one master shelf.

Steps
1. In the lower left pane of the Configuration Management tab, expand the Equipment
node in the configuration tree.
2. Double-click the Rack node. The Rack-List sub-tab is displayed in the right pane, see
Figure 3-3.

3-2
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 3 Hardware Configuration

Figure 3-3 Rack-List Sub-tab

3. Select the rack information in the table, and click


displayed, see Figure 3-4.

. The Rack Graph sub-tab is

Figure 3-4 Rack Graph Sub-tab

4. On the Rack Graph sub-tab, right-click the position where a shelf is to be added, and
select Shelf from the shortcut menu. The Shelf dialog box is displayed, see Figure
3-5.

3-3
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

Figure 3-5 Shelf Dialog Box

5. Click

, and click the close button in the top-right corner of the dialog box.

6. Add the other shelves as required.


End of Steps

3.4 Adding Boards


The following procedure describes how to add necessary boards in a shelf.

Steps
1. On the Rack Graph sub-tab, right-click the slot where a board is to be added, and
select Board from the shortcut menu. The Board dialog box is displayed, see Figure
3-6.

3-4
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 3 Hardware Configuration

Figure 3-6 Board Dialog Box

2. Click Senior.
3. Set parameters as required.
4. Click

5. Click the close button in the top-right corner of the dialog box.
6. Repeat the previous steps to add the other boards as required.
End of Steps

3.5 Creating a PLMN Group


This procedure describes how to create a PLMN Group.

Steps
1. In the lower left pane of the Configuration Managementtab,Plmn Group
Configuration > PLMN Group in the configuration tree.
2. Double-click thePLMN Groupnode.The PLMN Group-List sub-tab is displayed in the
right pane.
3. Click

.ThePLMN Group sub-tab is displayed, seeFigure 3-7.

3-5
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

Figure 3-7 PLMN Group

4. Set parameters as required.


5. Click

6. Click the close button on the Adjacent AAL2 Office sub-tab.


End of Steps

3.6 Creating a local PLMN Group


This procedure describes how to create a local PLMN Group.

Steps
1. In the lower left pane of the Configuration Managementtab,Plmn Group
Configuration > Local PLMN Group in the configuration tree.
2. Double-click theLocal PLMN Group node.The Local PLMN Group-List sub-tab is
displayed in the right pane.
3. Click

.TheLocal PLMN Group sub-tab is displayed, seeFigure 3-8.

3-6
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 3 Hardware Configuration

Figure 3-8 Local PLMN Group

4. Set parameters as required.


5. Click

6. Click the close button on the Adjacent AAL2 Office sub-tab.


End of Steps

3-7
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

This page intentionally left blank.

3-8
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 4

Transmission Configuration
(ATM Bearer)
Table of Contents
Transmission Configuration (ATM Bearer) Flow..........................................................4-1
Creating a Local AAL2 Office .....................................................................................4-1
Creating an Adjacent AAL2 Office ..............................................................................4-2
Creating an IMA Group...............................................................................................4-3
Creating IMA Links .....................................................................................................4-3
Creating an AAL2 Route.............................................................................................4-4
Creating an MTP3 Route............................................................................................4-5
Creating an MTP3 Route Set......................................................................................4-6

4.1 Transmission Configuration (ATM Bearer) Flow


The configuration flow for transmission that uses Asynchronous Transfer Mode (ATM)
bearer mode is as follows:
1.
2.
3.
4.
5.
6.
7.
8.

Creating
Creating
Creating
Creating
Creating
Creating
Creating
Creating

a Local AAL2 Office


an Adjacent AAL2 Office
an IMA Group
IMA Links
an AAL2 Route
an MTP3 Route
an MTP3 Route Set
an MTP2 Link

4.2 Creating a Local AAL2 Office


This procedure describes how to create a near-end signalling point.

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > ATM Configuration in the configuration tree.
2. Double-click Local AAL2 Office under the ATM Configuration node. The Local
AAL2 Office-List sub-tab is displayed in the right pane.
3. Click

. The Local AAL2 Office sub-tab is displayed, see Figure 4-1.


4-1

SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

Figure 4-1 Local AAL2 Office Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the Local AAL2 Office sub-tab.


End of Steps

4.3 Creating an Adjacent AAL2 Office


This procedure describes how to create an adjacent AAL2 office.

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > ATM Configuration > Local AAL2 Office in the configuration tree.
2. Double-click Adjacent AAL2 Office under the ATM Configuration node.
Adjacent AAL2 Office-List sub-tab is displayed in the right pane.
3. Click

The

. The Adjacent AAL2 Office sub-tab is displayed, see Figure 4-2.

Figure 4-2 Adjacent AAL2 Office Sub-tab

4. Set parameters as required.


4-2
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 4 Transmission Configuration (ATM Bearer)

5. Click

6. Click the close button on the Adjacent AAL2 Office sub-tab.


End of Steps

4.4 Creating an IMA Group


This procedure describes how to create an IMA group.

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > ATM Configuration in the configuration tree.
2. Double-click IMA Group under the ATM Configuration node in the configuration tree.
The ATM Configuration-List sub-tab is displayed in the right pane.
3. Click

. The IMA Group sub-tab is displayed, see Figure 4-3.

Figure 4-3 ATM Configuration Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the IMA Group sub-tab.


End of Steps

4.5 Creating IMA Links


This procedure describes how to create IMA links.
4-3
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > ATM Configuration > IMA Group in the configuration tree.
2. Double-click IMA Link under the IMA Group node. The IMA Link-List sub-tab is
displayed in the right pane.
3. Click

. The IMA Link sub-tab is displayed, see Figure 4-4.

Figure 4-4 IMA Link Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the IMA Link sub-tab.


End of Steps

4.6 Creating an AAL2 Route


This procedure describes how to create an ATM Adaptation Layer type 2 (AAL2) route.

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > ATM Configuration in the configuration tree.
2. Double-click AAL2 Route under the ATM Configuration node in the configuration
tree. The AAL2 Route-List sub-tab is displayed in the right pane.
3. Click

. The AAL2 Route sub-tab is displayed, see Figure 4-5.

4-4
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 4 Transmission Configuration (ATM Bearer)

Figure 4-5 AAL2 Route Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the AAL2 Route sub-tab.


End of Steps

4.7 Creating an MTP3 Route


The following procedure describes how to create a Message Transfer Part layer 3 (MTP3)
route.

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > No. 7 Signalling Configuration in the configuration tree.
2. Double-click Mtp3 Route under the No. 7 Signalling Configuration node. The Mtp3
Route-List sub-tab is displayed in the right pane.
3. Click

. The Mtp3 Route sub-tab is displayed, see Figure 4-6.

Figure 4-6 Mtp3 Route Sub-tab

4. Set parameters as required.


5. Click

.
4-5

SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

6. Click the close button on the Mtp3 Route sub-tab.


End of Steps

4.8 Creating an MTP3 Route Set


The following procedure describes how to create an MTP3 route set.

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > No. 7 Signalling Configuration in the configuration tree.
2. Double-click Mtp3 RouteSet under the No. 7 Signalling Configuration node. The
Mtp3 RouteSet-List sub-tab is displayed in the right pane.
3. Click

. The Mtp3 RouteSet sub-tab is displayed, see Figure 4-7.

Figure 4-7 Mtp3 RouteSet Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the Mtp3 RouteSet sub-tab.


End of Steps

4-6
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 5

Transmission Configuration
(IP Bearer)
Table of Contents
Transmission Configuration (IP Bearer) Flow..............................................................5-1
Creating an Ethernet Interface....................................................................................5-1
Creating an IPv4 Ethernet Interface............................................................................5-2
Creating a Static Route ..............................................................................................5-3
Creating an Association..............................................................................................5-4
Creating an ASP ........................................................................................................5-5
Creating an AS...........................................................................................................5-6
Creating an M3UA Route ...........................................................................................5-7
Creating an M3UA Route Set .....................................................................................5-7

5.1 Transmission Configuration (IP Bearer) Flow


The transmission configuration flow that uses Internet Protocol (IP) bearer mode is as
follows:
1.
2.
3.
4.
5.
6.
7.
8.

Creating
Creating
Creating
Creating
Creating
Creating
Creating
Creating

an Ethernet Interface
an IPv4 Ethernet Interface
a Static Route
an Association
an ASP
an AS
an M3UA Route
an M3UA Route Set

5.2 Creating an Ethernet Interface


The following procedure describes how to create an Ethernet interface.

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network IP Configuration > IP Interfaces Configuration in the configuration tree.
2. Double-click Ethernet Interface under the IP Interfaces Configuration node. The
Ethernet Interface-List tab is displayed in the right pane.
5-1
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

3. Click

. The Ethernet Interface sub-tab is displayed, see Figure 5-1.

Figure 5-1 Ethernet Interface Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the Ethernet Interface sub-tab.


End of Steps

5.3 Creating an IPv4 Ethernet Interface


The following procedure describes how to create an Ethernet interface that supports
Internet Protocol version 4 (IPv4).

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > IP Configuration > IP Interfaces Configuration > Ethernet Interface
in the configuration tree.
2. Double-click Ethernet IP Interface under the Ethernet Interface node. The Ethernet
IP Interface-List sub-tab is displayed in the right pane.
3. Click

. The Ethernet IP Interface sub-tab is displayed, see Figure 5-2.

5-2
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 5 Transmission Configuration (IP Bearer)

Figure 5-2 Ethernet IP Interface Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the Ethernet IP Interface sub-tab.


End of Steps

5.4 Creating a Static Route


The following procedure describes how to create a static route.

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > IP Configuration > Route Global Configuration in the configuration tree.
2. Double-click Static Route under the Route Global Configuration node. The Static
Route-List sub-tab is displayed in the right pane.
3. Click

. The Static Route sub-tab is displayed, see Figure 5-3.

5-3
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

Figure 5-3 Static Route Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the Static Route sub-tab.


End of Steps

5.5 Creating an Association


The following procedure describes how to create an association.

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > IP Configuration in the configuration tree.
2. Double-click Association under the IP Configuration node. The Association-List
tab is displayed in the right pane.
3. Click

. The Association sub-tab is displayed, see Figure 5-4.

5-4
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 5 Transmission Configuration (IP Bearer)

Figure 5-4 Association Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the Association sub-tab.


End of Steps

5.6 Creating an ASP


The following procedure describes how to create an Application Server Process (ASP).

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > No.7 Signalling Configuration > Near End Signalling Point > Adjacent
Office Information in the configuration tree.
2. Double-click ASP Configuration under the Adjacent Office Information node. The
ASP Configuration-List sub-tab is displayed in the right pane.
3. Click

. The ASP Configuration sub-tab is displayed, see Figure 5-5.

5-5
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

Figure 5-5 ASP Configuration Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the ASP Configuration sub-tab.


End of Steps

5.7 Creating an AS
The following procedure describes how to create an Application Server (AS).

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > No.7 Signalling Configuration > Near End Signalling Point > Adjacent
Office Information in the configuration tree.
2. Double-click AS Configuration under the Adjacent Office Information node. The
AS Configuration-List sub-tab is displayed in the right pane.
3. Click

. The AS Configuration sub-tab is displayed, see Figure 5-6.

Figure 5-6 AS Configuration Sub-tab

5-6
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 5 Transmission Configuration (IP Bearer)

4. Set parameters as required.


5. Click

6. Click the close button on the AS Configuration sub-tab.


End of Steps

5.8 Creating an M3UA Route


The following procedure describes how to create an MTP3User Adaptation layer protocol
(M3UA) route.

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > No. 7 Signalling Point in the configuration tree.
2. Double-click M3ua Route under the No. 7 Signalling Point node.
Route-List tab is displayed in the right pane.
3. Click

The M3ua

. The M3ua Route sub-tab is displayed, see Figure 5-7.

Figure 5-7 M3ua Route Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the M3ua Route sub-tab.


End of Steps

5.9 Creating an M3UA Route Set


The following procedure describes how to create an M3UA route set.

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > No. 7 Signalling Point in the configuration tree.
5-7
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

2. Double-click M3ua RouteSet under the No. 7 Signalling Point node. The M3ua
RouteSet-List sub-tab is displayed in the right pane.
3. Click

. The M3ua RouteSet sub-tab is displayed, see Figure 5-8.

Figure 5-8 M3ua RouteSet Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the M3ua RouteSet sub-tab.


End of Steps

5-8
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 6

Logical Links Configuration


Table of Contents
Logical Links Configuration Flow ................................................................................6-1
Creating a UMTS Logical Function Configuration .......................................................6-1
Creating a Near End Signalling Point..........................................................................6-2
Creating an Adjacent Office Information .....................................................................6-3
Creating an Iub Link ...................................................................................................6-4
Creating an Iucs Link..................................................................................................6-5
Creating an Iups Link .................................................................................................6-6
Creating an Iur Link ....................................................................................................6-7

6.1 Logical Links Configuration Flow


The office configuration flow is as follows:
1.
2.
3.
4.
5.
6.
7.

Creating
Creating
Creating
Creating
Creating
Creating
Creating

a UMTS Logical Function Configuration


a Near End Signalling Point
a Adjacent Office Information
an Iub Link
an Iucs Link
an Iups Link
an Iur Link

6.2 Creating a UMTS Logical Function Configuration


The following procedure describes how to create a Universal Mobile Telecommunication
System (UMTS) logical function configuration.

Steps
1. In the lower left pane of the Configuration Management tab, double-click the
UMTS Logical Function Configuration node. The UMTS Logical Function
Configuration-List sub-tab is displayed in the right pane.
. The UMTS Logical Function Configuration sub-tab is displayed, see
2. Click
Figure 6-1.

6-1
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

Figure 6-1 UMTS Logical Function Configuration Sub-tab

3. Set parameters as required.


4. Click

5. Click the close button on the UMTS Logical Function Configuration sub-tab.
End of Steps

6.3 Creating a Near End Signalling Point


The following procedure describes how to create a Near End Signalling Point.

Steps
1. In the lower left pane of the Configuration Management tab, double-click Transport
Network > No.7 Signalling Configuration in the configuration tree.
2. Double-click Near End Signalling Point under the No.7 Signalling Configuration
node. The Near End Signalling Point-List sub-tab is displayed in the right pane.
3. Click

. The Near End Signalling Point sub-tab is displayed, see Figure 6-2.

6-2
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 6 Logical Links Configuration

Figure 6-2 Near End Signalling Point Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the Near End Signalling Point sub-tab.
End of Steps

6.4 Creating an Adjacent Office Information


The following procedure describes how to create an Adjacent Office Information.

Steps
1. In the lower left pane of the Configuration Management tab, expand Transport
Network > No.7 Signalling Configuration > Near End Signalling Point in the
configuration tree.
2. Double-click Adjacent Office Information under the Near End Signalling Point
node. The Adjacent Office Information-List sub-tab is displayed in the right pane.
3. Click

. The Adjacent Office Information sub-tab is displayed, see Figure 6-3.

6-3
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

Figure 6-3 Adjacent Office Information Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the Adjacent Office Information sub-tab.


End of Steps

6.5 Creating an Iub Link


The following procedure describes how to create an Iub link.

Steps
1. In the lower left pane of the Configuration Management tab, expand UMTS Logical
Function Configuration > Link Configuration in the configuration tree.
2. Double-click Iub Link under the Link Configuration node. The Iub Link-List sub-tab
is displayed in the right pane.
3. Click

. The Iub Link sub-tab is displayed, see Figure 6-4.

6-4
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 6 Logical Links Configuration

Figure 6-4 Iub Link Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the Iub Link sub-tab.


End of Steps

6.6 Creating an Iucs Link


The following procedure describes how to create an Iucs link.

Steps
1. In the lower left pane of the Configuration Management tab, expand UMTS Logical
Function Configuration > Link Configuration in the configuration tree.
2. Double-click Iucs Link under the Link Configuration node. The Iucs Link-List
sub-tab is displayed in the right pane.
3. Click

. The Iucs Link sub-tab is displayed, see Figure 6-5.

6-5
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

Figure 6-5 Iucs Link Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the Iucs Link sub-tab.


End of Steps

6.7 Creating an Iups Link


The following procedure describes how to create an Iups link.

Steps
1. In the lower left pane of the Configuration Management tab, expand UMTS Logical
Function Configuration > Link Configuration in the configuration tree.
2. Double-click Iups Link under the Link Configuration node. The Iups Link-List
sub-tab is displayed in the right pane.
3. Click

. The Iups Link sub-tab is displayed, see Figure 6-6.

6-6
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 6 Logical Links Configuration

Figure 6-6 Iups Link Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the Iups Link sub-tab.


End of Steps

6.8 Creating an Iur Link


The following procedure describes how to create an Iur link.

Steps
1. In the lower left pane of the Configuration Management tab, expand UMTS Logical
Function Configuration > Link Configuration in the configuration tree.
2. Double-click Iur Link under the Link Configuration node. The Iur Link-List sub-tab
is displayed in the right pane.
3. Click

. The Iur Link sub-tab is displayed, see Figure 6-7.

6-7
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

Figure 6-7 Iub Link Sub-tab

4. Set parameters as required.


5. Click

6. Click the close button on the Iur Link sub-tab.


End of Steps

6-8
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 7

Configuration Check and


Synchronization
Data synchronization refers to synchronizing the database data of the Network
Management Server (NMS) to NEs.
Data synchronization involves all data synchronization and modified data synchronization.
When all data synchronization or modified data synchronization is being performed, the
system performs global check on the configured data.

Table of Contents
Synchronizing All Data ...............................................................................................7-1
Synchronizing Modified Data ......................................................................................7-2

7.1 Synchronizing All Data


The following procedure describes how to synchronize all data.

Context
l
l

Data check is performed before synchronizing all data.


Connected to the Network Element.

Prerequisite
All data is configured

Steps
1. In the upper-left pane of the Configuration Management tab, right-click an NE, and
select Synchronize All Data from the shortcut menu. The Global Check dialog box
is displayed. By default, the System information tab is displayed, see Figure 7-1.

7-1
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

Figure 7-1 Global Check Dialog Box-System information Tab

2. Click Start.
3. Click Next. A dialog box is displayed.
4. Enter the verification code, and click OK. A dialog box is displayed.
5. Click Close.
End of Steps

7.2 Synchronizing Modified Data


The following procedure describes how to synchronize modified data.

Context
l
l

Data check is performed before synchronizing the modified data.


Connected to the Network Element.

Prerequisite
The data is modified.

7-2
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Chapter 7 Configuration Check and Synchronization

Steps
1. In the upper-left pane of the Configuration Management tab, right-click an NE, and
select Synchronize All Data from the shortcut menu. The Global Check dialog box
is displayed. By default, the System information tab is displayed, see Figure 7-2.
Figure 7-2 Global Check Dialog Box-System information Tab

2. Click Start.
3. Click Next. A dialog box is displayed.
4. Enter the verification code, and click OK. A dialog box is displayed.
5. Click Close.
End of Steps

7-3
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

This page intentionally left blank.

7-4
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Figures
Figure 1-1 Initial Configurations Flow ........................................................................ 1-1
Figure 2-1 Subnetwork Sub-tab ................................................................................ 2-1
Figure 2-2 Element Sub-tab ...................................................................................... 2-2
Figure 2-3 Managed Element Configuration Tree...................................................... 2-3
Figure 3-1 Rack-Table Mode Sub-tab........................................................................ 3-1
Figure 3-2 Rack Sub-tab........................................................................................... 3-2
Figure 3-3 Rack-List Sub-tab .................................................................................... 3-3
Figure 3-4 Rack Graph Sub-tab ................................................................................ 3-3
Figure 3-5 Shelf Dialog Box ...................................................................................... 3-4
Figure 3-6 Board Dialog Box..................................................................................... 3-5
Figure 3-7 PLMN Group............................................................................................ 3-6
Figure 3-8 Local PLMN Group .................................................................................. 3-7
Figure 4-1 Local AAL2 Office Sub-tab ....................................................................... 4-2
Figure 4-2 Adjacent AAL2 Office Sub-tab.................................................................. 4-2
Figure 4-3 ATM Configuration Sub-tab ...................................................................... 4-3
Figure 4-4 IMA Link Sub-tab ..................................................................................... 4-4
Figure 4-5 AAL2 Route Sub-tab ................................................................................ 4-5
Figure 4-6 Mtp3 Route Sub-tab................................................................................. 4-5
Figure 4-7 Mtp3 RouteSet Sub-tab ........................................................................... 4-6
Figure 5-1 Ethernet Interface Sub-tab ....................................................................... 5-2
Figure 5-2 Ethernet IP Interface Sub-tab................................................................... 5-3
Figure 5-3 Static Route Sub-tab................................................................................ 5-4
Figure 5-4 Association Sub-tab ................................................................................. 5-5
Figure 5-5 ASP Configuration Sub-tab ...................................................................... 5-6
Figure 5-6 AS Configuration Sub-tab ........................................................................ 5-6
Figure 5-7 M3ua Route Sub-tab................................................................................ 5-7
Figure 5-8 M3ua RouteSet Sub-tab........................................................................... 5-8
Figure 6-1 UMTS Logical Function Configuration Sub-tab......................................... 6-2
Figure 6-2 Near End Signalling Point Sub-tab ........................................................... 6-3
Figure 6-3 Adjacent Office Information Sub-tab......................................................... 6-4
Figure 6-4 Iub Link Sub-tab....................................................................................... 6-5
Figure 6-5 Iucs Link Sub-tab ..................................................................................... 6-6
I
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

ZXWR RNC Initial Configuration Guide

Figure 6-6 Iups Link Sub-tab..................................................................................... 6-7


Figure 6-7 Iub Link Sub-tab....................................................................................... 6-8
Figure 7-1 Global Check Dialog Box-System information Tab ................................... 7-2
Figure 7-2 Global Check Dialog Box-System information Tab ................................... 7-3

II
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential

Glossary
AAL2
- ATM Adaptation Layer type 2
AS
- Application Server
ASP
- Application Server Process
ATM
- Asynchronous Transfer Mode
EMS
- Element Management System
GUI
- Graphical User Interface
IP
- Internet Protocol
IPv4
- Internet Protocol version 4
M3UA
- MTP3-User Adaptation layer protocol
MTP3
- Message Transfer Part layer 3
NMS
- Network Management Server
OMM
- Operation & Maintenance Module
UMTS
- Universal Mobile Telecommunication System

III
SJ-20140527134425-012|2014-07-28 (R1.0)

ZTE Proprietary and Confidential