Q.1) The minimum size waste pipe for a residential kitchen sink is ____.
A. 3 inches
B. 2-1/2 inches
C. 2 inches (Correct Answer)
D. 1-1/2 inches (Your Answer)
Incorrect
Q.2) All trenches deeper than the footing of any building or structure and paralleling the
same must be at least ____.
A.
B.
C.
D.
Correct
Q.3) Of the four board subjects given for Master Plumbers examination, which of this
subject was originally split into two subjects?
A. Plumbing Code
B. Design and Installations
C. Plumbing Arithmetic
D. Practical Problems (Your Answer)
Correct
Q.4) Water service pipes, or any underground water pipes, shall not be run or laid in the
same trench with ____.
A.
B.
C.
D.
Correct
Q.5) A device to prevent backflow into the potable water system is called a ____.
*
A. backflow connection
B. siphon leg
C. backflow preventer (Your Answer)
D. back-siphonage
Correct
Q.6) Cast-iron soil pipe shall not be ____.
A.
B.
C.
D.
Correct
used belowground
painted
used for drain lines
threaded (Your Answer)
Q.9) Hub and spigot cast-iron piping in 10-foot lengths, installed horizontally, shall be
supported at intervals of not more than ____.
A. 10 feet (Your Answer)
B. 12 feet
C. 5 feet
D. 15 feet
Correct
Q.10) A water heater vent may have one offset of not more than 60 degrees from the ____.
A. heater
B. horizontal
C. roof
D. vertical (Your Answer)
Correct
Q.11) Except for plastic piping systems, hot and cold water piping may be tested with ____.
A. 100 psi air for at least 10 minutes
B. 35 psi air for at least 15 minutes
50 psi air or the working pressure of the water in the system for at least 15
C.
minutes (Your Answer)
D. 40 psi air or 150 psi water for 10 minutes
Correct
Q.12) The distance from the center of a water closet to any side wall or partition shall not
be closer than ____.
A. 15 inches (Your Answer)
B. 12 inches
C. 24 inches
D. 30 inches
Correct
Q.13) Unions shall be installed in a water supply system within ____ to a water heater
A. 36 inches
B. 12 inches (Your Answer)
C. 24 inches
D. 48 inches
Correct
Q.14) Single-wall metal pipe shall terminate at least 5 feet in vertical height above the
highest connected equipment ____.
A. within a horizontal distance of 10 feet
B. draft hood
C. draft hood outlet or flue collar (Your Answer)
D. or approved cap on the roof
Incorrect
Q.15) The maximum length for a 1-1/2-inch vent pipe is ____.
A. 50 feet
B. 60 feet (Correct Answer)
C. 20 feet
D. 30 feet (Your Answer)
Correct
Q.16) The minimum common horizontal waste pipe serving a bathtub, a lavatory, and a
Correct
Q.21) The developed length between the trap of a water closet and its vent shall not exceed
____.
A. 4 feet
B. 12 inches
C. 30 inches
D. 6 feet (Your Answer)
Correct
Q.22) Sheet metal, constituting a part of any vent connector, shall be at least ____.
A. 0.0304 inches (Your Answer)
B. 0.0505 inches
C. 0.0500 inches
D. 0.0450 inches
Incorrect
Q.23) The maximum number of lavatories on a 2-1/2 inch horizontal waste line is ____.
A. 10
B. 14 (Correct Answer)
C. 20
D. 6 (Your Answer)
Correct
Q.24) The vertical distance between a fixture outlet and the trap weir shall not exceed ____.
A. 18 inches
B. 36 inches
C. 12 inches (Your Answer)
D. 24 inches
Correct
Q.25) The minimum requirement for the slope of horizontal drainage pipes between
manholes is
A. 4%
B. 2-1/2 %
C. 2% (Your Answer)
D. 3%
Incorrect
Q.26) A branch line serving a trap in a combination waste and vent system is required to be
separately vented when the length of the branch exceeds ____.
A. 15 (Correct Answer)
B. 10 (Your Answer)
C. 5
D. 25
Correct
Q.27) Water heater vents terminate above a roof surface at least ____ from a vertical wall.
*
Q.31) The vent for a kitchen sink serves as a drain for a laundry tub. The size of the wetvented section is ____.
A. 1-1/2 inches (Your Answer)
B. 3 inches
C. 2-1/2 inches
D. 2 inches (Correct Answer)
Incorrect
Q.32) Pilots and burners of gas-fired water heaters (except sealed combustion chambers) in
residential garages shall be ____ above the floor level.
A. 24 inches
B. 12 inches (Your Answer)
C. 18 inches (Correct Answer)
D. 6 inches
Incorrect
Q.33) No water heater (except direct vent water heaters and fuel burning water heaters
installed in a closet with a listed, gasketed door assembly and listed self-closing
device) that depends on the combustion of fuel for heat shall be installed in any
____.
_
A. garage
B. kitchen
C. basement (Your Answer)
D. bedroom (Correct Answer)
Incorrect
Q.34) The sizing of gas vents for category II, III and IV shall be in accordance with ____.
A. the manufacturers guide (Your Answer)
B. the manufacturers instructions (Correct Answer)
C. the gas company
D. the vent connector company
Correct
Q.35) What kind of joint is not allowed in cast iron pipe?
A. welded
B. bell and spigot
C. threaded (Your Answer)
D. soldered
Incorrect
Q.36) Gas piping with pressure less than 1/4-inch water column shall stand an air test of
____.
A. 50 psi
B. 30 psi (Your Answer)
C. 15 psi
D. not less than 3 psi (Correct Answer)
Incorrect
Q.37) No trap for any clothes washer standpipe shall be installed ____.
A. 18 inches above the floor
B. in a partition (Your Answer)
C. 6 inches above the floor
D. below the floor (Correct Answer)
Correct
Q.38) Vitrified clay building sewer pipe and fittings are ____.
A. unrestricted in use for drain lines
B. unrestricted in use for vent lines
C. approved for use inside of buildings and aboveground
D. approved for use at least 12 inches belowground (Your Answer)
Correct
Q.39) A ____ trap is not self-cleaning
A. plaster
B. cast-iron
C. bell
D. grease (Your Answer)
Correct
Q.40) Joints at the roof around pipes shall be made watertight by the use of ____.
A. epoxy glue
B. flashings (Your Answer)
C. waterproof paint
D. tar and paper
Incorrect
Q.41) A vent in a combination waste and vent system shall be approximately equal in area
to one-half the ____.
B. 12 inches
C. 2 inches (Your Answer)
D. 9 inches
Incorrect
Q.52) In each run of horizontal drain piping, the distance between cleanouts shall not
exceed ____.
A. 50 feet (Your Answer)
B. 300 feet
C. 75 feet
D. 100 feet (Correct Answer)
Correct
Q.53) Under no circumstances may gas appliance pressure regulators be vented ____.
A. to the gas utilization equipment flue or exhaust system (Your Answer)
B. using black iron pipe
C. to the combustion chamber near the pilot
D. to the atmosphere
Correct
Q.54) A domestic dishwasher drain shall first connect to ____.
A. an approved airgap fitting (Your Answer)
B. a double-check valve
C. a triple-check valve
D. an approved valve
Correct
Q.55) For a vertical drainage line that is installed to be truly in vertical position, what is the
allowed degree of the branch to be used?
*
A. 15
B. 60 (Your Answer)
C. 45
D. 22.5
Correct
Q.56) Nonmetallic shower sub-pans or linings may be built up on the job site of not less
than ____.
C. a closet bend
D. metal supporting members (Your Answer)
Correct
Q.62) Concealed slip joint connection require a (an) ____.
A. 8 x 12 access panel
B. 10 x 12 access panel
C. 12 x 12 access panel (Your Answer)
D. 18 x 18 access panel
Correct
Q.63) A refrigerator used to store food and that requires drainage shall be drained by means
of ____.
A. an indirect waste pipe (Your Answer)
B. both A and B
C. a direct connection
D. no drain required
Correct
Q.64) Fixture traps shall have a water seal of not less than ____.
A. 12 inches
B. 2 inches (Your Answer)
C. 6 inches
D. 4 inches
Correct
Q.65) The maximum horizontal distance of a trap arm is measured from the inner edge of
the vent to the ____.
A. outlet
B. weir of the trap (Your Answer)
C. dip
D. inlet
Incorrect
Q.66) One trap may serve a set of not more than ____.
C. two lavatories
D. three lavatories (Your Answer)
Incorrect
Q.67) Water closet tank ballcocks shall be installed with the vacuum breaker critical level at
least ____.
A. 1 inch above the flush valve opening (Your Answer)
B. 6 inches above the full opening of the overflow tube
C. 1 inch above the full opening of the overflow tube (Correct Answer)
D. 6 inches above the flush valve opening
Correct
Q.68) One material not approved for the installation of an external trap for a urinal is ____.
A. ABS
B. cast brass
C. drawn-brass tubing traps (Your Answer)
D. cast iron
Correct
Q.69) Because of structural conditions, a 4-inch house drain is installed with a slope of 1/8
inch per foot. This installation will result in a(an) ____.
A. increased scouring and cleansing action
B. reduction in fixture unit loading allowance (Your Answer)
C. separation of solids and liquid
D. increased allowance in fixture unit loading
Incorrect
Q.70) Three-quarter inch or 1-inch gas piping installed horizontally shall be supported at
intervals not to exceed ____.
A. 6 feet
B. 4 feet (Your Answer)
C. 8 feet (Correct Answer)
D. 5 feet
Incorrect
Q.71) When sizing a copper fuel-gas piping system that has an inlet pressure of less than 2
psi with a pressure drop of 0.3 inch w.c., the maximum cubic feet per hour of gas
flow allowed through a 5/8-inch O.D. ACR tube 75 feet in developed length is ____.
A. 13
B. 48 (Your Answer)
C. 27 (Correct Answer)
D. 68
Correct
Q.72) What kind of concealed connections on fixtures that it is required to provide an
access panel or utility at least 0.3 meter in its least dimension for easy inspection and
repair?
A. 48 (Your Answer)
B. 24
C. 36
D. 32 (Correct Answer)
Incorrect
Q.91) The total number of closets on a 3-inch stack is ____.
A. four (Correct Answer)
B. three (Your Answer)
C. two
D. six
Incorrect
Q.92) Sewer or other drainage piping that shall no be installed under or within 2 feet of any
building or structure is ____.
A. ABS (Your Answer)
B. cast iron
C. asbestos cement (Correct Answer)
D. copper