I.
General
To design adequate fin glass of a curtain wall meeting required criteria.
All units is in metric system.
II.
Design Calculation
1
Design Code
BS 8118 Part 1:1991:Structural Use of Aluminium. Code of Practice for design
ASCE 7-05 Min. Design Loads for Buildings and other Structures
Material used
Allowable stress, heat strengthened Glass
33.00
N/mm2
49.00
N/mm2
138.00
N/mm2
Modulus of Elasticity, E
72000.00
N/mm2
G
v
:
:
28300.00
0.22
N/mm2
Loading
Dead Load (DL)
Wind Load
0.4238
kN/m2
:
45.00
m/s 3-sec gust
:
45 /
1.78
25.28
m/s
Refering to table 4, mean hourly speed wind may be assessed by dividing 3 sec gust wind
by Sb factor (1.78) at 10m height for site in country.
:
Length of Building, L
75.20
m
:
Width of Building, W
75.00
m
:
Height of Bldg., H
122.00
m
Basic Wind Speed, v
Load Combination
1.250
F2
500
15
6000
1262
156250000
140625
625000
250
562500
mm
mm
mm
mm
mm4
mm4
mm3
mm
mm4
kpa
1.25 x
6000 mm
1.5775 x
1.26 =
1.5775
N/mm
6000 ^2 / 8 =
15
7,098,750 Nmm
^3 / [6x(1+0.22)] =
33.20
11.36
Mpa
<
49
Mpa ok
kNm > M ok
kN/m2
1.25 x
6000 mm
1.125E+13
2.37 mm
1.262 =
1.5775
<
N/mm
6000
180 =
60
33.3
A-A
Rw
50
Rd
s=
120
400
Fin
300
Rw
Glass panel size:
internal
air space
external
4.7325 kN
Fin glass:
=
=
=
=
=
8
1.5
8
0.424
0.397
Dead load:
Rd1
Rd2
Rd
=
=
=
3208.95 N
1191.92 N
4400.87 N
Check the
3
nos. of M
Max shear force act on the bolt
V =
1.4
= 9047.53
Max shear resistance of one bolt
Vrs =
310
= 97233.5
mm
mm
mm
kPa
kPa
=
=
x ( 4732.5 ^2 +
4401 ^2)^0.5
N
= 9047.53 /
4 = 2261.88 N
x
157 x
N > V ok
100
6 mm SS angle
400 x
320000
1.4 x
6x
2=
4.7325 x
1000 =
6625.5
590400
mm3
85
4800
mm2
563.1675 Nmm
20
> V ok
205
:
:
60
2.20
:
:
:
:
160
400
132026
2.9
nos
0.88
:
:
:
4.7325
0.7888
6.248
kN
kN
kN
> v...Pass!
0.88
:
:
:
4.4009
0.7335
3.696
kN
kN
kN
> t...Pass!
4.2 x
mm
kN
N/mm2
mm
Nmm
mm
26 x
150
nos
:
:
:
4.7325
0.7888
21.8
kN
kN
kN
> v...Pass!
:
:
:
4.4009
0.7335
26
kN
kN
kN
> t...Pass!
M 10 x 50 LG hex. Bolt/nut
272
222
150
150
400