You are on page 1of 6

MT ALTAIR TRADER ENGINE ROOM UMS CHECK LIST

ITEM

CHECK POINT

SET
POINT

A-DECK
Galley A/C
Prov. Ref plant
Temperature

Suc. Pressure

Bar

Del. pressure

Bar

Meat Room

(-15/-18)

Fish room

(-17/-20)

Vegetable room

(+6/+4)

Lobby

(+12/+8)

Centr.Cool.
Check Level
exp.Tk
Scrubber tower Level

Normal
Normal

ER Upper Dk
Emergency
gene.

Quick close v/v


Tk.

Insulation

MOHM

Pressure

Bar

Pressure
Delivery
A/C compressor temperature
Load

Bar

Fan 1

Amps

Fan 2

Amps

< 80
Amps

2nd DECK
D/C Atlas Copco
Sewage Plant
Steam
reduc.valv
EGE Soot
blowers
Ex Gas
Econom.
Boiler controls

Pressure/Temp.

Normal

Lube oil level

Normal

Compress/Lo Level Normal


Check Air Press.

Normal

Pressure 7/3 bar

Bar

Control panel

Aut/Man

Diff, pressure

<150

Check settings

Auto

YEAR: _________ MONTH:_________________DAY FROM:____________

PAGE 1 OF 6

MT ALTAIR TRADER ENGINE ROOM UMS CHECK LIST

Incinerator

Work. Conditions

Run/stop

Lube oil level

Normal

Freon level

Normal

Pr.Refrig.Compr
Suc. Pressure.
No.1 or No.2

Bar

Del . pressure

Bar

Lube oil pressure

Bar

Elevator
Air reserv.dr.
syst.
Main engine
Load
Air Comps

Check L.O. level

Normal

Check position

Auto

Check settings

1 on
auto

Generators
Main
switchboard

Check settings

Stand by

Insulation 440 V

OK

Suct. pressure

Bar

Del. pressure

Bar

LO. Level

Normal

Water level

Normal

Steam pressure

Normal

Main air
compres.

Lube oil level

Normal

Auto drain traps

OK

Aux. Air
compres.

Lube oil level

Normal

Auto drain trap

OK

Air Reservoirs
Air Reducing
valv.
Control air

Pressure

Normal

Control pressure

Bar

Pressure

Bar

Suction pressure

Bar

Delivery pressure

Bar

H.P Pumps

LPSS

ECR- Air cond

Check Performance < 85%

S/G ROOM
Pump No.1/2/3 Working

OK

PAGE 2 OF 6

MT ALTAIR TRADER ENGINE ROOM UMS CHECK LIST

Exhaust fan
Pressure
gauges
H.Exp Foam Tk.

Working

OK.

Sea water/Foam

OK.

Level

OK

Leakage

NO

4th DECK
Auto B/W Filter Diff. pressure

Bar

FO Purifier 1 or Flow
2
Press

M3

LO Purifier 1 or Flow
2
Press
M/E viscosity
Check operation
unit
Fuel oil sludge
Check
Tk
LO. Sludge Tk. Check

M3

FO. Service Tk. Check

Level

FO. Settl. Tk.

Check

Level

FO. Boiler Tk.


Boil. FO.Burn
p/p

Check

Level

Operation

Auto/Ma
n

L.O. Pressure

Bar

Bar

Bar
OK
Level
Level

Turbo
Generator

Normal
Lube oil level
Governor
OK
condition
Gland steam press. Bar

T/G Vacuum
pump

Vacuum
Sealing Tk wat.
level
Lube oil level
Pressure/Temperat
ure
Lube oil level

mmHg

Suction press.

Bar

Delivery. press

Bar

D/G No.1 or
No.2
Boil.LP
circ.pump

Normal
Normal
Normal
Normal

PAGE 3 OF 6

MT ALTAIR TRADER ENGINE ROOM UMS CHECK LIST

S.W Serv. pump Delivery press


HT. FW Cool p/p
A/C Workshop

Suction press

Bar

Delivery press.

Bar

Suction press.

Bar

Delivery press.
After T/C No.1
Exh. Gas press. Press.
After T/C No.2
Press
No.1 Pressure drop

T/C air filter

Bar

Bar
KPa
KPa
Bar

No.2 Pressure drop Bar

PART DECK
Pressure-5.0Mpa

Cyl.Lubric.p/p

Bar

Ampers Less 4.5 A Amp.


L.O Cool. Fan cond. OK

M/E Local side Pressure gauges

OK

M/E Local side Control air 0.7 MPa

OK

Exhaust valve
Air cooler
Oil mist
detector
LO. B/W filter
LT.Cool.FW.P/p

Air Set
OK
pres.0.55Mpa
No.1 Pressure drop Bar
No.2 Pressure drop Bar
Less 3 Gr. Lights
Diff. pressure

Bar

Suct. pressure

Bar

Deliv. pressure

Bar

FO.Transf. pump Auto running.


Fresh Water
Gen.

OK

OK

ppm

OK

Temperature

Vacuum

Distillate pump Working condition

OK

Ejector pump

OK

Working condition

PAGE 4 OF 6

MT ALTAIR TRADER ENGINE ROOM UMS CHECK LIST

FO. Drain tank


T/G Vac.
Condens
Aux fed wat.
p/p

Check level

L x 100

Check water level

OK

Lube oil level

Normal

Suction press.

Bar

Delivery press.

Bar

LOWER PART
Bilge well

Check level

OK

Bilge separator Run/Stop

OK

Bilge pump

Run/Stop

OK

Sludge pump

Run/Stop

OK

Bilge space

Light/leakage

OK

Emergency exit Lighting

OK

LO. Sump Tk.

M3

Level

M/E LO. Pumps Delivery press.


Main Cool
Delivery press.
SW.p/p
DC Voltage

MGPS

Current
Flow meter
condition
Clean drain Tk. Level

Bar
Bar
V
Amps
OK
M3

T/G Vac.Con.
p/p

Suction press.

Bar

Delivery press.

Bar

S/T Seal
system

Check air pressure 0.7 Bar

Forward seal Tk Check level

35NL/mi
n
> 150
mm

Lube oil.Tk.

Check level

Norm

LO. Drain Tk.

Check level

Norm

Flow meter

S/T L.O. pumps Delivery press.


S/T LO. cooler
Interm/Shaft
press.

Bar

Check temperature OK
0.3-0.5 Bar

Bar

PAGE 5 OF 6

MT ALTAIR TRADER ENGINE ROOM UMS CHECK LIST

Shaft/Hull m.V

Check m.V.

2-50 mV

Bilge Tk.

Level

M3

TIME
RANK
DUTY ENG. SIGNATURE
C/E SIGNATURE

PAGE 6 OF 6