You are on page 1of 48

Maintenance record of gas turbine equipment in he fei

Generating
Running repair(firing
Moderate repair(heat
Rush repair
unit
chamber inspection)
passage inspection)
number
Inspection
Service
Inspection
Service
Inspection
Service
date
hours when
date
hours
date
hours
inspection
when
when
inspection
inspection
NO.1gas
99.5.82710
turbine
99.5.2
NO.1gas
00.8.203420
turbine
01.1.12
NO.2gas
99.7.192694
turbine
99.8
NO.2gas
02.5.294292
turbine
02.7.12
NO.1gas
02.12.115096
turbine
03..4.1
NO.2gas
03.1.164711
turbine
03.4.12
Inspection list for flame tube
Generating unit
Inspection date
Service hours when
Number of
number
inspection
inspection
Number of retreat
NO.1gas turbine
2000.11
3420
3
NO.2gas turbine
2002.6
4292
4
NO.1gas turbine
2003.4
5096
10
NO.2gas turbine
2003.4
4711
10
Inspection list for transition piece
Generating unit
Inspection date
Service hours when
Number of
number
inspection
inspection
Number of retreat
NO.1gas turbine
2000.11
3420
10
NO.2gas turbine
2003.4
5096
10
NO.1gas turbine
2003.4
4711
10

Generating unit
number
NO.1gas turbine
NO.2gas turbine
NO.1gas turbine
NO.2gas turbine

Inspection list for 1st stage nozzle


Inspection date
Service hours when
inspection
2000.8
2002.6
2003.4
2003.4

3420
4292
5096
4711

Number of
inspection
Number of retreat
1
1
1
1

Construction design for Hefei 250MW gas turbine project

1. General situation for project


1.1 Conditions of power plant address
1.1.1 General situation for power plant address
Hefei power plant is located on the northwest suburb of hefei
city, and about 6.5 kilometre to cantonal district. The hewa
highway is about 1 kilometre to the north of power plant,
hence, it is easy to go to cantonal part because the junction
of road and hewa highway.
The project is extended construction in the scope of power
plant, and the new power plant is to be located on this
extended area that is average height 33 meter and flat.
1.1.2 Weather condition
The he fei city is characterized by gentle weather, clear four
seasons, moderate precipitation rain fall and clear season wind
weather which located on middle part of jianghuai highland.
Air temperature: Average temperature for years
15.7
The highest temperature for years
39.1
The lowest temperature for years
-13.5
Air
pressure:
Average
pressure
for
years
1012.9hPa
The highest pressure for years
1044hPa
The lowest pressure for years
972.3hPa
Rainfall: The biggest rainfall for years
1541.9
The smallest rainfall for years
694.3
Average rainfall(a year)for years
1008.1
The biggest rainfall for 24 hours
129.6
The biggest rainfall(a time)for years
149.7
Humidity: The smallest relative humidity for years
8%
Average relative humidity for years
26%
The biggest absolute humidity for years
40.4 hPa
(1-1)
Power: 38.73MW (15, relative humidity 60%)
Heat consumption: 11370KJ/KWh (15, relative humidity 60%)
Rated revolution: 5114rpm
First critical speed: 1648rpm
Second critical speed: 3864rpm
Third critical speed: 7867rpm
Gas turbine generator: Type number: T600C
Type: closed air-cooled gas turbine
Power factor: 0.8

Electrical pressure: 11KV


Frequency: 50HZ
Revolution speed: 3000rpm
Construction design for Hefei 250MW gas turbine project

Power: 39MW
1.2.1.2 Waste heat boiler:
Type: self- circulation, horizontal, double-pressure
Rated intermediate pressure evaporative capacity: 64t/h
Rated steam outlet pressure: 4.2MPa
Rated steam outlet temperature: 510
Rated outlet flow: 64t/h
Rated deoxidation evaporative capacity: 10t/h
Feed water temperature: 110
Make-up water temperature: 30
Condensate temperature: 35
1.2.1.3 Steam turbine generator:
Steam turbine: type number: TM2 357/1007CD
Type: double-cylinder side flow condensing
turbine
Revolution speed: 3000rpm
Rated output: 38.8MW (ISO operating
conditions)
(1-3)
The power supply for steam turbine and power plant area, was
from lower side 6.3KV of #5 combined transformer in power plant
though reactor 6KV generatrix section that was connected two sets of
low pressure plant transformers and three sets of 6KV high
electromotors. The two sets of low pressure transformers (capacity
are 1250KVA and 1600KVA respective) supply the 380/220V load for all
power plant except the load for supply gas turbine island operation.
The DC system of gas turbine was supplied by ALSTHOM as
suitable set, and a set of 125V, 210Ah cadmium- nickel accumulator
and two sets of chargers were provided at the same time.
A set of 220V, 200Ah anti- acid cadmium- nickel accumulator was
mounted in central control room, and used to control protection and
light system of central control building, power plant area and boost
station.
The excitation system of gas turbine generator was supplied by
ALSTHOM as suitable set, and was no-brush revolution excitation
system.
The gas turbine system was completed extempore control in the
extempore control room TCC, and the equipments controlled in central
control room were one-to-one strong electricity control.

1.2.5 Heat control part:


The distributed computer system was applied in this project
based on the controllability of main equipment and trait of gas-steam
turbine combined cycle, and carried out the functions such as
monitoring, control, protection interlock and alarm.
1.2.6 Water engineering part:
Construction design for Hefei 250MW gas turbine project

The water supply of hefei power plant was from dongpu


reservoir, and the surplus of make-up water could use in this
project. The circulating feed water system with cooling tower was
applied in circulating water system, and the type-TSC-10F-3000
composite mechanical vent cooling tower was applied in cooling
equipment, and a circulating water pump room was built around cooling
tower, and there were three sets of circulating water pumps for steam
turbine and the three for gas turbine.
A new make-up water pump well is to be located on zhang da tang
for make-up water system.
The chemical make-up water was from 1500m 3 water pool built by
power plant, and three sets of chemical make-up water pump were
settled the west side of compositive pump room in power plant in
addition.
1.2.7 Chemical part of power plant:
The design of make-up water treating system output based on
265t/h water used in waste heat boiler and gas turbine, and this
project of chemical water equipment was extended at old base of
chemical water system, and the new output of demineralization water
was 27.6t/h.

8.2 Supply plan for main equipments


8.2.1 Generator unit professional equipment:
Sequence
Name
Type and standard
number
1
Supporting plate,
foundation bolt and base
plate for gas turbine
2
Gas turbine
3
Gas turbine generator
4
Accessorial system
(1) Accessorial gear box and coupling
equipment in gas turbine
body
(2) Start and cooling system
(3) lubricating and hydraulic oil
system
(4) fuel oil system
(5) LP spray air system
(6) electronical component
(7) light system for accessorial room
(8) rain protection shell for outdoor
assembly
(9) inner water cooling system
(10) heat and vent system
(11) compressor bleed system
(12) inlet and outlet control system

Unit

Quantity

Delivery date
961020

set
set
set

21
21
21

961231
961231
961231

set
set

21
21

961231
961231

set
set
set
set
set

21
21
21
21
21

961231
961231
961231
961231
961231

set
set
set
set

21
21
21
21

961231
961231
961231
961231

Accessorial system
equipment out gas turbine
body

Fuel treating equipment

(13) trip oil system


(14) fire protection and alarm system
(15)discharge frame fan
(1)control room for gas turbine (TCC)

set
set
set
set

21
21
21
21

961231
961231
961231
961231

(2)fuel filter system


(3) intermediate pressure tank for
generator
(4) CO2 reservoir
(5) washing system
(6) vanadium depressor module (put into
operation when heavy oil burned)
(7) fuel oil heat module
(8) fuel oil prepositive pump module
(9) oil demister

set
set

21
21

961231
961231

set
set
set

21
21
21

961231
961231
961231

set
set
set

21
21
21

961231
961231
961231

(10) blowdown tank(1m3) and pump


(11) filling water module
(12) cooling water heat exchanger for
gas turbine
Centrifugal, 1st stage separate, total
output >=20m3 /h
The capacity of gentle oil used by two
sets of gas turbines, the K+Na<1ppm in
fuel after treated

set
set
set

21
21
21

961231
961231
961231

set

970110

Including (1) double-coupling oil


filter
(2) fuel oil transmission pump
(3) pressure control valve
(4) self-clear separator
(5) blowdown oil tank
(6) blowdown oil pump
(7) common base plate
(8) control panel
7
8
9
10
(1)
(2)
(3)

(4)
(5)

The whole set of waste


heat boiler
The whole set of steam
turbine
Steam turbine generator
Fuel oil system
Oil reservoir accessories
Purification oil
reservoir accessories
Discharge oil pump for
gentle oil
Electromotor ( protective
expansion type)
Handle oil pump
Blowdown water pump
Electromotor

set

970110

set
set
set
set
set
set
set

2
1
2
1
1
1
1

970110
970110
970110
970110
970110
970110
970110
970110
971231
971231
961231
961231
961231

80CYZ-55 type,65m3 /h,55mH2o

set

961231

YB160-2gajf,18.5KW,380v

set

961231

S38gajf,2.34-3.54m3/h,0.29MPa
CFY50-40-125,12.5 m3/h,20mH20
3KW

set
set
set

1
2

961231
961231
961231

(6)
7

(8)

(9)

Coarse oil filter


Blowdown oil pump
Electromotor( outdoor
protective expansion
type)
Oil-water separator

Fuel oil intermediate


pump
11
The others
(1)
Drain flash tank
(2)
Instrument of air
compressor
(3)
Drain pump
3.2.2 Electric equipment part
Sequence
Name
number
Part one
Outdoor electrical
equipment part
1
Main transformer
2
3
Insulation switch
4
Current mutual inductance
5
Arrester

PN2.5,ND150,20
CFY50-40-160 12.5 m3/h 32mH20
4KW,2950rpm

set
set
set

2
1

961231
961231
961231

CYF-2B type, treating ability 2m3/h,


discharge requirement<10mg/l,
Electromotor 0.8KM,380V
36 m3/h,30 mH20

set

961231

set
set

961231
961231

3.5m
ZW-0.9/7 (equipped with buffer)

set
set

2
2

970130
970130

IS50-32-125,15 m3/h,0.2MPN

set

970130

Type and standard

Unit

Quantity

Delivery date

set
SFP7-50000/200 50000KVA
SFP7-90000/220 90000KVA
GW13-110 400A single sole
LQF-10 0.5/C 400A
YW-100/260

set
set
set
piece
piece

970110
1
1
2
2
2

970110
970110
970110
970110
970110

6
7
8
9
10
11
12
13
14
15
16
17
18
Part two
1
2
3
4

SF6 breaker
Current mutual inductance
Insulation switch
Insulation switch
Arrester
Voltage mutual inductance
Grouping terminal block
Grouping terminal block
Tension resistance
insulation sub-bunch
Overhang insulation subbunch
Stanchion insulation
terminal
Steel core aluminium
thread
Steel core aluminium
thread
Cubicle part of generator
connections
6KV switch cabinet
(inlet)
Current mutual inductance
Terminal box
Slot type aluminium

LW6-200(W) 3150A,40KA
LCWB-200(W) 2600/5A 5P/5P/5P/5P/0.5
GW-220(I)D(W) 1250A 31.5KA
GW-220(II)D(W) 1250A 31.5KA
YIOW-200/520
TYD220/ 3-0.02H
220 0.1 0.1
XJ-1
XJ-2

set
set
set
set
piece
piece
piece
piece
set

3
9
4
1
3
3
5
18

970110
970110
970110
970110
970110
970110
970110
970110
970110

piece

970110

piece

970110

meter

560

970110

meter

45

970110

970110

10

set

970110

piece
piece
meter

6
1
30

970110
970110
970110

Part
three
1
2
3
4
5
6
7
8
9
10
Part
four
1
2
3

conductor
Plant consumption part

970110

Reactor
High voltage switch
cabinet(vacuum breaker)
High voltage switch
cabinet(vacuum breaker)
Dry transformer (with
shell)
Dry transformer (with
shell)
Low voltage switchboard
Low voltage switchboard
Low voltage switchboard
Power control box
Inspection tool set
Control, protection and
DC part
220KV circuitry control
panel
Main transformer control
panel
Control panel for gas
turbine generator

11

piece
set

3
7

970110
970110

set

970110

set

970110

set

970110

piece
piece
piece
piece
piece

6
21
12
30
6

970110
970110
970110
970110
970110
970110

piece

970110

piece

970110

piece

970110

4
5
6
7
8
9

10
11
12
13
14
15
Part
five
1

Control panel for steam


turbine generator
Central signal control
panel
Control panel for plant
power supply
Central signal relay
screen
Protection screen for
steam turbine generator
Excitation regulating
screen for steam turbine
generator
Protection screen for
main transformer
Protection screen for
plant transformer
Ammeter board
DC board
Charger board
Accumulator
The cable and frame

piece

970110

piece

970110

piece

970110

piece

970110

piece

970110

piece

970110

piece

970110

piece

970110

piece
piece
piece
piece

2
6
2
104

970110
970110
970110
961231

Single core polyethylene


power cable

Meter

4600

961231

12

Single core polyethylene


power cable
3
Three cores polyethylene
power cable
8.2.3 Heat control professional equipment:
Sequence
Name
number
Part one
Heat engineering
equipment
1
Distribute
computer
system
(1)
Operator station
(2)
Engineer station
(3)
DCS cabinet
2
Gas turbine control
system
3
BTG control pedestal
4
Switchboard
5
Power supply panel for
instrument
6
Relay panel
7
NCC cabinet
8
UPS cabinet
9
Fire alarm panel
10
Thermostat container

Type and standard

meter

3600

961231

meter

360

961231

Unit

Quantity

Delivery date
970110

set

13

970110

set

12

970110
970110
970110
970110

piece
piece
piece

12
1
2

970110
970110
970110

piece
piece
piece
piece
piece

2
4
3
2
25

970110
970110
970110
970110
970110

11
12

Junction box
Heat control system for
chemical water treatment
13
Heat control system for
fuel oil
8.2.4 Chemical water professional equipment:
Sequence
Name
number
Part one
Equipment
1
Positive ion exchanger
2
Negative ion exchanger
3
Combined bed
4
Demineralization water
tank
5
Demineralization water
pump
6
Intermediate water pump
7
Automatic ammonia
regulator
8
Group connection
phosphate regulator
9
Carbon dioxide
elimination device of
group connection
Part two
Material

Type and standard

piece
set

160
1

970110
970110

set

970110

Unit

Quantity

Delivery date

set
set
set
set

1
1
1
1

961231
961231
961231
961231
961231

set

961231

set
set

1
1

961231
961231

set

961231

piece

961231

961231

14

1
2
3
4

Positive colophony
Negative colophony
Quartz sand layer
50 multi-surface
plastic hollow ball
8.2.5 Warming and vent professional equipment:
Sequence
Name
Type and standard
number
1
Type RF77W rooftop aircondition
2
T35-11-#6, 3 shaft flow
ventilator
3
T35-11-#6, 3shraft flow
ventilator
4
T33-11-#4 shaft flow
ventilator
5
FT-35-11-#3,15 shaft flow
ventilator
6
FT-35-11-#2,8 shaft flow
ventilator
7
Exhaust smoke ventilator
for fire protection
8
NJWT-NO12.5 rooftop
ventilator
9
Scattering flow device
Type CT211-2,500500, aluminium alloy

15

stere
Stere
ton
stere

5.5
7.4
17
4.1

961231
961231
961231
961231

Unit

Quantity

Delivery date

set

961231

set

961231

set

961231

set

961231

set

961231

set

961231

set

961231

set

10

961231

piece

961231

for rectangle vertical


slice type

10

Return wind inlet

11

Closed control valve

Control valve for fire


protection
13
Type 701-6 complex
impedance muffler
14
Abio-glass steel vent
pipe
15
Warming blade
16
Check valve
17
Check valve
8.2.6 Feed water part equipment:
Sequence
Name
number
Part one
Pump group
1
Circulating water pump
for steam turbine
Suitable motor

Type
Type
Type
Type

CT211-2,400400, aluminium
CT211-2,320320, aluminium
BFK-I-S 800630 aluminium
BFK-I-S 320320 aluminium
Type T308-1 1250630
800500

12

Type and standard

Y400-54-6
N=400KW,U=6000V

16

alloy
alloy
alloy
alloy

piece
piece
piece
piece
piece
piece
piece

9
4
10
4
5
3
4

961231
961231
961231
961231
961231
961231
961231

piece

961231

ton

18

961231

piece
piece
piece

330
160
6

961231
961231
961231

Unit

Quantity

Delivery date

set

970731

970731
970731

set

4
5

Part two
1
Part
three
1
2
3

Circulating water pump


for gas turbine
Suitable motor
Discharge water pump for
circulating water pump
room
Suitable motor
Make-up water pump
Water pump for fire
protection
Suitable motor
Chemical make-up water
pump
Suitable motor
Cooling equipment
Mechanical vent cooling
tower
Lifting equipment

200S42

set

961231

Y255M-2
IS50-32-125

set
set

3
2

961231
961231

Y90S-2/1.5

set
set
set

2
2
3

961231
961231
961220

set
set

3
3

961220
961231

set

961231

set

970110

set

970110

set

970110

set

970110

Electricity drive singlebeam suspension crane


Electricity drive singlebeam suspension crane
Cycle-chain handle
operation panel

17

Part
four
1
2
3

Big diameter valve


Electricity drive
butterfly valve
Electricity drive
butterfly valve
Hydraulic buffer check
butterfly valve

970110

set

970110

KD741X-V-10
Dn800 Pn1MPa

set

Electricity drive
butterfly valve
Block blowdowm equipment

Part
five
1
Surface filter gauze
3m2.7m
2
Surface filter gauze
2m2m
Part six
Pipe material
1
Welding steel pipe
14208
2
Welding steel pipe
3776
3
Welding steel pipe
2736
4
Welding steel pipe
2196
8.2.7 The material boom of relay protection for system:
Sequence
Name
Type and standard
number
1
Protection cabinet for
GH901, within LFP-901A,GSF-8A,CZXhigh frequency direction
11,LX-800

18

970110
set
set

3
5

970110
970110

set
set

2
1

970131
970131

meter
meter
meter
meter

530
250
1300
950

961030
961030
961030
961030

Unit

Quantity

Delivery date

3
4
5
6
7
8
9
10
11
12
13

Protection cabinet for


high frequency closedlock

AC:100V,5A,DC:220V, current for opened


trip:2.2A, current for closed
trip:1.1A
GH902, within LFP-902A,GSF-6A,CSQ1,LX-800

set

970130

AC:100V,5A,DC:220V

set
set

1
1

970130
970130

set

970130

set

970130

set

970130

set

970130

set
set
piece
meter
meter

1
2
2
540
540

970130
970130
970130
970130
970130

set

970130

220KV circuitry failure


hold cabinet
Differential protection
220KV single generatrix
High-frequency choke
device
High-frequency choke
device
Capacitance type voltage
mutual inductance device
Coupling capacitor
Coupling filter
Grounded brake
High-frequency cable
Anti-jamming shield
copper wire
Generatrix protection
outdoor grouping terminal

19

block
8.2.8 The control and automatization part for system:
Sequence
Name
Type and standard
number
1
Computer movement device
2
Telemetry transmitter
cabinet
3
Telemetry exchanger
cabinet
4
Continuous power supply
panel
5
Control cable
6
Control cable
7
Special-control shield
cable for computer
8
Special-control shield
cable for computer
9
Special-control shield
cable for computer
8.2.8 The communication part for system:
Sequence
Name
Type and standard
number
1
High-frequency choke
device
2
Coupling capacitor

20

Unit

Quantity

Delivery date

set
set

1
1

970130
970130

set

970130

set

970130

meter
meter
meter

150
250
200

970130
970130
970130

meter

200

970130

meter

200

970130

Unit

Quantity

Delivery date

set

970130

set

970130

3
4
5

Coupling filter
Grounded brake
High-frequency cable

set
set
meter

21

1
1
210

970130
970130
970130

Section 2: Technical specifications for steam turbine unit


Name
Item
Unite
Data
Steam
Type number
TM2-41.6/100.7
turbine
Type
Impulse condensing
type turbine
The stage for high pressure casing
stage
6
Nozzle arc segment number for high
piece
4
pressure casing
The stage for low pressure casing
stage
7
Nozzle arc segment number for high
piece
1
pressure casing
Power
KW
41031
Revolution speed for high pressure
r/min
9435
casing
Revolution speed for low pressure
r/min
4301
casing
Revolution speed for generator
r/min
1500
Inlet temperature for high pressure

5055
casing
Outlet temperature for high pressure

266
casing
Inlet pressure for high pressure
Bar abs
40
casing
Outlet pressure for high pressure
Bar abs
6.31
casing
Inlet temperature for low pressure

266
casing
Outlet temperature for low pressure

34.5
casing
Inlet pressure for low pressure
Bar abs
6.3
casing
Outlet pressure for low pressure
Bar abs
0.055
casing
Revolution direction(from turbine
Anticlockwise
head)
Manufacturer
GEC ALSTHOM
Generator
Type number
AG220M161
Type
Horizontal air-cooled
convex non-brush
excitation generator
Pole number
pole
4
Phase number
phase
3
Rated capacity
KVA
47625

22

Rated power
Rated voltage
Rated current
Rated power factor
Rated speed
Overspeed value
Cooling type

KW
KV
A

40481
11.00
2500
0.85
r/min
1500
r/min
1800
IC8AIW7(CACW aircooled)

t/s
piece
hz
Clockwise

The highest temperature of stator


The highest temperature of rotor
Inlet temperature for cooling water
Cooling water flow
Cooler number
Frequency
Revolution direction(from generator
head)
Manufacturer
GEC ALSTHOM
Excitatio
Type number
MAJ51M20
n
Pole number
pole
12
generator
Phase number
phase
3
Rated power
KW(DC)
106
Rated voltage
V(DC)
163
Rated current
A
700
The highest temperature

120
Rated frequency
HZ
150
Permanent
Type number
55/44
magnet
Phase number
phase
1
generator
Rated voltage
V
240
Output voltage
V(AC)
205
Output current
A(AC)
18.2
Frequency
HZ
275
Section 3: Technical specifications for accessorial equipment
Name
Item
Unite
Data
Main
Type number
T1023208
lubricating
Drive type
Decelerated gear box
Oil pump
Outlet pressure of pump
Bar
3.5
Flow
L/min
1448
Speed
r/min
1500
Lubricating oil tank capacity
L
11300
Manufacturer
FLUAVIS
Accessorial
Type number
T10232080C
Lubricating
Outlet pressure of pump
Bar
1.2

23

Oil pump

Emergency
Oil pump

Control oil
pump

Circulating
Water pump
For steam
turbine

Outlet
butterfly
valve for
Circulating
Water pump
Deaerator

Condenser

Flow
Speed
Manufacturer
Type number
Outlet pressure of pump
Flow
Speed
Manufacturer
Type number
Outlet pressure of pump
Flow
Speed
Control oil tank capacity
Type number
Type
Motor power
Rated voltage
Rated current
Motor speed
Raise
Flow
Allowable steam corrosion margin
Manufacturer
Type number
Nominal diameter(DN)
Working
temperature
Type number
Design pressure
Design temperature
Test pressure
Working pressure
Manufacturer
Type number
Type
Cooling surface
Length
Width

24

L/min
r/min

900
1500
FLUAVIS
T10231360C
Bar
1.2
L/min
900
r/min
1500
FLUAVIS
PV62R1C
bar
120
L/min
12
r/min
1500
L
260
600S-32A
Centrifugal type
KW
280
V
6000
A
33.4
r/min
989
m
27
3
m /h
2880
m
7.5
Water pump factory in
lanzhou city of gansu
Y100L2-4

800

Less than
80
75T
KPa
100

250
KPa
400
KPa
20
Plant boiler factory in
wuxi city
N-2940-1
Double-route surface
axial inlet
3
m
2940

7220

3370

Oil cooler

Condensate
Water pump

Height
Type number
Water side
Allowable working temperature
Design pressure
Test pressure
Capacity
Cooling water flow
Inlet temperature for cooling
water
Temperature rise for cooling water
Inlet oil temperature
Outlet temperature
Type number
Type
Motor power
Rated voltage
Rated current
Motor speed
Raise
Flow
Allowable steam corrosion margin
Manufacturer

Low pressure
Feed water
pump

Type number
Type
Motor power
Rated voltage
Rated current
Motor speed
Raise
Flow
Allowable steam corrosion margin
Manufacturer

Intermediate
Pressure
Feed water
pump

Type number
Type
Motor power
Rated voltage
Rated current
Motor speed
Raise

25

3300
OK40/320
Oil side

80
80
Bar
6
6
Bar
9
9
L
210
210
3
m /h
108

Max:34

6
76
50

6LDTN-7
Axial flow type
KW
55
V
380
A
103.3
r/min
1470
M
84
3
m /h
160
m
1.4
Shenyang water pump
factory
Y132S2-2
Centrifugal type
KW
7.5
V
380
A
15
r/min
2900
m
75
3
m /h
12.5
m
2
Rizhao water pump
factory in shangdong
DG85-678
Centrifugal type
KW
220
V
380
A
393
r/min
2980
M
536

Flow
Allowable steam corrosion margin
Manufacturer
Water-cycle
Vacuum pump

Discharge
oil-smoke
fan
Decelerating
Gear box

Ball
cleaning
pump

Receiving
ball
net

Type number
Type
Motor power
Rated voltage
Rated current
Motor speed
Bleed speed
Absolute pressure of suction inlet
Absolute pressure of discharge
outlet
Water consumption
Manufacturer
Type number
Flow
Speed
Type number
Low speed end

Input speed
Output speed
Power
lubricating oil flow
lubricating oil pressure
Normal input oil temperature
The highest input oil temperature
Type number
Type
Flow
Raise
Shaft power
Manufacturer
Type number
Working pressure
Manufacturer

26

m3/h
85
m
4
Rizhao water pump
factory in shangdong
2BE1253-OBD4
Centrifugal type
KW
75
V
380
A
152.1
r/min
740
3
m /min
38.417.2
KPa
101.33.3
KPa
101.3
m3/h
26
Foshan water pump
factory in Guangdong
AERCOLOGY
3
m /h
450
r/min
3000
TSD105C
High
speed
end
r/min
9435
4301
r/min
1500
1500
KW
17550 25700
L/min
815
815
Bar
1.5
1.5

45

65
125SS-1,2
Centrifugal type
3
m /h
62
m
12
KW
4
Qingdao electric power
equipment factory
BSF-800
MPa
0.3
Qingdao electric power
equipment factory

Cooling
tower
Fan

Type number
Type
Motor power
Rated voltage
Rated current
Motor speed
Fan speed
Flow
Full pressure
Blade angle
Manufacturer

LF-85
Centrifugal type
KW
160
V
380
A
289
r/min
1486
r/min
149
3
m /h
2730000
Pa
152
degree
90
Baoding airscrew
factory
Fan for
Type number of motor
X-F/A-5
steam
Type
Axial flow type
Turbine room
Motor power
KW
0.37
3
Flow
m /h
7655
Wind pressure
Pa
138.2
Speed
r/min
1450
Manufacturer
Yingxing motor factory
Make-up
Type number
150QGW200-30
water
Type
Centrifugal type
Pump for gas
Motor power
KW
30
Turbine at
Rated voltage
V
380
zhangdatang
Rated current
A
58
Motor speed
r/min
980
3
Flow
m /h
200
Raise
m
30
Manufacturer
Shanghai kaili pump
factory
Pump for gas
Type number
80SG-50-30
Turbine
Motor power
KW
7.5
pipe
Rated voltage
V
380
Rated current
A
15
3
Flow
m /h
50
Raise
M
30
Speed
r/min
2800
Section 4: system protection value
System
Point name
Name
Value Unit
Remarks
lubricatin 01GGRPSH020
The pressure for
1.5
bar
Alarm
g oil
lubricating oil mothersystem
pipe(high)
01GGRPSH010
The outlet pressure
3.0
bar
Alarm

27

01GGRPSL014

01GGRPSL015

The pressure for


lubricating oil motherpipe(lowvalue)

0.7

bar

01GGRPDL016

The pressure for


lubricating oil motherpipe(lowvalue)
The pressure
difference for
lubricating oil
strainer(high)
Lubricating oil
temperature for
lubricating oil
tank(low)
Lubricating oil
temperature
for lubricating oil
tank(high)
Design pressure for
control oil
The pressure for
control oil
(lowvalue)

0.6

bar

Alarm,
start
lubricating
oil pump
Alarm,
start
lubricating
oil pump
Alarm, trip

0.9

bar

Alarm

40

Alarm

65

Alarm

140

bar

105

bar

90

bar

Alarm,
start standby control
oil pump
Alarm, trip

bar

Alarm

7.4

bar

Alarm, trip

0.22

bar

Alarm, trip

01GGRPDISH01
1

01GGRTBL020

01GGRTBH020

Control
and
safety
system

for main lubricating


oil pump(high)
The pressure for
lubricating oil motherpipe(lowvalue)

01GFRPSL112

01GFRPSL113

01GFRPDISH11
5
01GSEPSHH210

01GSETSHH302

The pressure for


control oil
(lowvalue)
The pressure
difference for control
oil filter(high)
The discharge
pressure for high
pressure
turbine(high)
The discharge
pressure for low

28

1.2

bar

Shaft
gland
system

pressure
turbine(high)
01GSETSHH302
The discharge
temperature for low
pressure
turbine(high)
01CETTT160
The steam
temperature for shaft
gland(normal)
01CETTSH160
The steam
temperature for shaft
gland(high)
01CETTSL160
The steam
temperature for shaft
gland(low)
01CETPT154
The steam pressure
for shaft
gland(normal)
01CETPBH154
The steam pressure
for shaft gland(high)
01CETPBL154
The steam pressure
for shaft gland(low)
01GMATBH200
The temperature for
thrust bearing of HP
cylinder(high value)
01GMATBHH20
The temperature for
0
thrust bearing of HP
cylinder(high value)
01GMATBH201
The temperature for
bearing of HP cylinder
inlet side(high
value)
01GMATBHH20
The temperature for
1
bearing of HP cylinder
inlet side(high
value)
01GMATBH202
The temperature for
bearing of HP cylinder
outlet side(high
value)
01GMATBHH20
The temperature for
2
bearing of HP cylinder
outlet side(high

29

220

Alarm, trip

240

310

Alarm

180

Alarm

120

KPa

400

KPa

Alarm

100

KPa

Alarm

115

Alarm

120

Alarm, trip

115

Alarm

120

Alarm, trip

115

Alarm

120

Alarm, trip

01GMATBH300

01GMATBHH30
0
01GMATBH301

01GMATBHH30
1

01GMATBH302

The
monitori
ng
And
controllin
g
System
for
Steam
turbine
and
generato
r

01GMATBHH30
2

01GMATBH401
01GMATBH402

01GMATBHH40
1
01GMATBHH40
2
01GMATBH403

01GMATBH405

01GMATBHH40
301GMATBHH40
5

value)
The temperature for
thrust bearing of LP
cylinder(high value)
The temperature for
thrust bearing of LP
cylinder(high value)
The temperature for
bearing of LP cylinder
inlet side(high
value)
The temperature for
bearing of LP cylinder
inlet side(high
value)
The temperature for
bearing of LP cylinder
outlet side(high
value)
The temperature for
bearing of LP cylinder
outlet side(high
value)
The bearing
temperature for
deceleration gear box
of HP cylinder
side(high value)
The bearing
temperature for
deceleration gear box
of HP cylinder
side(high value)
The bearing
temperature for
deceleration gear box
of LP cylinder
side(high value)
The bearing
temperature for
deceleration gear box
of LP cylinder
side(high value)

30

115

Alarm

120

Alarm, trip

115

Alarm

120

Alarm, trip

115

Alarm

120

Alarm, trip

115

Alarm

120

Alarm, trip

115

Alarm

120

Alarm, trip

01GMATBH501

01GMATBHH50
1

01GMATBH502

01GMATBHH50
2

01GMAZSH200

01GMAZSHH20
0
01GMAZSH300

01GMAZSHH30
0
01GMAYSH201
204
01GMAYSHH20
1204
01GMAYSH301
304
01GMAYSHH30
1304

The bearing
temperature for gear
side of
generator(high
value)
The bearing
temperature for gear
side of
generator(high
value)
The bearing
temperature for
excitation side of
generator(high
value)
The bearing
temperature for
excitation side of
generator(high
value)
The axial
displacement for HP
rotor(big value)
The axial
displacement for HP
rotor(big value)
The axial
displacement for LP
rotor(big value)
The axial
displacement for LP
rotor(big value)
The bearing vibration
for HP cylinder(big
value)
The bearing vibration
for HP cylinder(big
value)
The bearing vibration
for LP cylinder(big
value)
The bearing vibration
for LP cylinder(big

31

115

Alarm

120

Alarm, trip

80

Alarm

90

Alarm, trip

0.4
7

Alarm

0.6
2

Alarm, trip

0.5
0

Alarm

0.6
5

Alarm, trip

43

Alarm

57

Alarm, trip

63

Alarm

84

Alarm, trip

01GMAYSH501
504
01GMAYSHH50
1504
01GEXTBH503

01GEXTBH513
01GEXTBHH503
01GEXTBHH513
01GRATBH520
01GRATBH521

01GRATBHH520
01GRATBHH521

01GRATBH522

01GRATBHH522

The
condens
ate
water
system

01CEXLBH001

01CEXLBH002

value)
The bearing vibration
for gear box of
generator(big value)
The bearing vibration
for gear box of
generator(big value)
The temperature for
loop of generator
stator(high value)
The temperature for
loop of generator
stator(high value)
The cool-wind
temperature for aircooler of
generator(high
value)
The cool-wind
temperature for aircooler of
generator(high
value)
The hot-wind
temperature for aircooler of
generator(high
value)
The hot-wind
temperature for aircooler of
generator(high
value)
The water level for
condenser(high
value)

The water level for


condenser(high
value)

32

75

Alarm

95

Alarm, trip

120

Alarm

130

Alarm, trip

51

Alarm

56

Alarm, trip

68

Alarm

73

Alarm, trip

430

480

Normal
make-up
water gate
closed
automatica
lly
Emergency
discharge
water gate
opened

01CEXLBHH001

The water level for


condenser(high
value)

630

01CEXLBL001

The water level for


condenser(low
value)

330

01CEXLBL002

The water level for


condenser(low
value)

280

01CEXLBLL001

The water level for


condenser(low
value)

100

01CEXPBH001

The outlet pressure


for condensate
pump(normal)
The outlet pressure
for condensate
pump(low)
The design value for
condensate water
flow

5.0

bar

2.0

bar

160

t/h

01CEXPBL001

01CEXPDBH101

01CEXPDBH101

The design value for


condensate water
flow

200

t/h

01CEXPDBH101
/201

The pressure
difference for inlet

KPa

33

automatica
lly
Condensat
e water
pump and
system trip
Normal
make-up
water gate
opened
and
emergency
make-up
pump
closed
automatica
lly
emergency
make-up
pump
opened
automatica
lly
Condensat
e water
pump and
system trip

Alarm and
pass-by
trip
Single
condensate
pump
operation
double
condensate
pumps
operation
Alarm

Feed
water
and
deoxidati
on
system

strainer of
condensate pump
1AFSRLBH100
The water level for
0
intermediate pressure
drum(high value)
1AFSRLBHH100
The water level for
+70
intermediate pressure
drum(high value)
1AFSRLBHHH10
The water level for
+120
0
intermediate pressure
drum(high value)
1AFSRLBL100
The water level for
-100
intermediate pressure
drum(low value)
1AFSRLBLL100
The water level for
-140
intermediate pressure
drum(low value)
1AFSRLBLL100
The water level for
-300
intermediate pressure
drum(low value)
1AFLBLV105
The design water
0
level for low pressure
drum
1AFLBLBH105
The water level for
+60
low pressure
drum(high value)
1AFLBLBHH105
The water level for
+70
low pressure
drum(high value)
1AFLBLBHHH10
The water level for
+90
5
low pressure
drum(high value)
1AFLBLBL105

1AFLBLBLL105

1AFLBLBLLL105

The water level for


low pressure
drum(low value)
The water level for
low pressure
drum(low value)
The water level for
low pressure
drum(low value)

34

Alarm

Alarm

Alarm and
boiler trip

Alarm

Alarm

Alarm and
boiler trip

Alarm

Alarm

-60

Signal was
constraine
d, boiler
un-trip
Alarm

-100

Alarm

Signal was
constraine
d, boiler
un-trip

1AADGLT108
1AADGLBH108

1AADGLBL108

1AADGLBLL108

1AADGPT110
1AADGPBH110
1AADGPBL110
1AAPBHSPTNO
K

1AFSRLPBH103

1AFSRLPBHH10
3
1AFLBPBH104

1AFLBPBHH104

The design water


level for deaerator
The water level for
deaerator(high)

900

Alarm

1380

The water level for


deaerator(low
value)
The water level for
deaerator(low
value)

700

Alarm and
condensate
pump trip
Alarm

500

The working pressure


for deaerator
The pressure for
deaerator (high)
The pressure for
deaerator (low)
The outlet pressure
for intermediate
pressure feed water
pump(low value)
The outlet pressure
for intermediate
pressure feed water
pump(low value)
The outlet pressure
for low pressure feed
water pump(low)

20

KPa

35

KPa

Alarm

10

KPa

Alarm

4.8

MPa

Alarm and
start standby pump

3.0

MPa Pass-by trip

0.6

MPa

The pressure for


intermediate pressure
drum(high value)
The pressure for
intermediate pressure
drum(high value)
The pressure for low
pressure drum(high
value)
The pressure for low
pressure drum(high

35

Alarm and
intermediat
e, low
pressure
feed water
pump trip

4.58

Alarm and
start standby
Pump
MPa
Alarm

4.65

MPa

0.3

MPa

0.4

MPa

Alarm and
safety door
?
Alarm

Alarm and
safety door

Circulatin
g water
system

01CRFPBH803
01CRFPBH804
01CRFTBH801
01CRFTBH802
01CRFTBH803
01CRFTBH804

01CRFTBH805
01CRFTBH806
Main
steam
system

1AVVPTE003

1AVVPTE100

1AVVPTBH100

1AVVPTBL100
Condens
er
system

01CVIPBL001

01CVIPBH001

01CVIPBH002

01CVIPBHH002

The

01CVITBH201

0.11

MPa

38

?
Alarm and
pass-by
trip
Alarm

44

Alarm

40

Alarm

300

507

512

Main steam
temperature(low)
The pressure for
condenser(low)

500

7.5

KPa

The pressure for


condenser(high
value)
The pressure for
condenser(high
value)

10

KPa

12

KPa

The pressure for


condenser(high
value)
The temperature for

30

KPa

60

value)
The outlet pressure
for circulating
water(low)
The inlet temperature
for circulating
water(high)
The outlet
temperature for
circulating
water(high)
The outlet
temperature for oilcooler water(high)
The main steam
temperature is
eligible
The rated
temperature for main
steam
Main steam
temperature(high)

36

Alarm and
attenuator
operated
automatica
lly
Alarm
Alarm and
the standby pump
was
stopped
Alarm

Alarm and
the standby pump
was started
Alarm and
pass-by
trip
Alarm and

other
system
01GHPTSHH004

01GHPPBHH00
1

seal water of vacuum


pump(high)
The temperature for
2nd stage attenuator
back of pass-by(high)
The pressure for
pass-by lower(high)

110

1.0

MPa

vacuum
pump trip
Alarm and
pass-by
trip
Alarm and
pass-by
trip

Chapter one: the technical specifications of the unit and main


equipment
Section one: the technical specifications of the unit
Manufacturer: EGT-ALSTOM in the France
1.
Type number: PG6551-B; PG: packaged; 6:6000 series;55: 5510n PH;
2.
1:single shaft; B: design number
the unit number: T781,T782
3.
speed: turbine/generator: 5114/3000r/min
4.
fuel: light oil
5.
low level heat: 43100KJ/kg
6.
ISO standard: technical condition with base load(15,1013.5mbar,
7.
60%RN)
the pressure difference for inlet: 120WC
8.
the pressure difference for outlet of simple circulation: 65WC
9.
10. terminal total output for generator: 38200KW
11. total heat consumption rate: 1185KJ/kwh(standard state, and with
base load)
12. inlet temperature of turbine: 10931104
13. discharge steam temperature: 537(in fact: #1 560,#2 540)
V15% O2
14. NOx:65PPm
Section two: the technical specifications of main equipment
1. Compressor
1.1 Type: shaft flow type
1.2 Speed: 5114r/min
1.3 The connection type of shell: surface flange connection
1.4 rotating guide vane type: hydraulic governing type
1.5 Stage: 17

37

1.6 inlet temperature: 15 (design value)


1.7 inlet pressure: 1.013bar (0.1013MPa)
1.8 inlet flow: 511t/h
1.9 pressure ratio: 10
2. Firing chamber
2.1 Type: divided pipe return flow
2.2 Number: 10
2.3 Firing device: tow pieces of electric spark plugs should extend
and withdraw and fix on NO.1 and NO.10 firing chamber
respectively
2.4 Flame detector: four pieces of ultraviolet detector should fix on
NO.2, NO.3, NO.7, and NO.8 firing chamber respectively
2.5 Fuel: light oil
2.6 discharge flow for gas turbine: 522t/h
3. Turbine
3.1 Type: single shaft flow
3.2 The connection type of cylinder: horizontal flange connection
3.3 Speed: 5114r/min
3.4 Stage: 3
3.5 Inlet temperature: 10931104
3.6 Discharge steam temperature: 537 (standard state, with base
load)
4. Main fogged-air compressor
4.1 Type: centrifugal
4.2 Type number: SCF-6
4.3 Speed: 45561r/min
4.4 Inlet pressure: 147PSIG (1.03MPa)
4.5 Outlet pressure: 221.5/261PSIG (1.558/1.837MPa)
4.6 Inlet temperature: 107
4.7 Drive device: accessorial gear box
5. Priming (accessorial) fogged-air compressor
5.1 Type: rotating and shaft flow type
5.2 Type number: D12D2-250
5.3 Speed: 3500r/min
5.4 Drive device: diesel engine and strap
6. Load gear box
6.1 Input speed: 5114r/min
6.2 Output speed: 3000r/min
6.3 Transmission ratio: 1.7045
6.4 Tooth number for gear: 44 and 75
6.5 Lubricating oil pressure: 1.8bar
6.6 Power: 54000KW
7. Accessorial gear box
7.1 Type number: AA510A

38

7.2 Output speed:


5114r/min(connected with turbine shaft)
3600r/min(connected with cooling water pump)
1884r/min(connected with main fuel oil pump)
45561r/min(connected with main fogged-air pump)
1445r/min(connected with main lubricating oil pump)
1445r/min(connected with main hydraulic oil pump)
7.3 Lubricating oil flow: 1.7bar, 100L/m
8. Cooling water pump
8.1 Type: centrifugal
8.2 Speed: 3600r/m
8.3 Working pressure: 8.3bar
8.4 Flow: 2300L/m
8.5 Power: 47.7KW
8.6 Drive device: accessorial gear box
9. Main lubricating oil pump
9.1 Type: column- stuff type
9.2 Speed: 1445r/min
9.3 Working pressure: 4.6bar
9.4 Flow: 1745L/m
10 Fuel heater module
10.1 Total power: 252KW (736KW)
10.2 Voltage: 400V
10.3 Working pressure: 16bar
10.4 Test pressure: 24bar
10.5 The min-temperature for inlet: -20
10.6 The max-temperature for outlet: less than 135
10.7 Single heater power: 36KW
11. Lubricating oil tank
11.1 The lubricating oil level(high): the height from oil level to
top: 305
11.2 The lubricating oil level(low): the height from oil level to
top: 406
11.3 High oil level alarm: the height from oil level to top: 254
11.4 Low oil level alarm: the height from oil level to top: 432
12. Heater
12.1 The heater for auxiliary equipment: 18KW, 380V
12.2 The heater for turbine: 18KW, 380V
12.3 The heater for lubricating oil: 20.4KW, 380V
12.4 The heater for generator: 6KW, 16A, 380V
12.5 The heater for MV room: 16A, 230V
12.6 The heater for accumulator: 16A, 230V
12.7 The heater for MV shell: 6A, 230V
Section three: the technical specifications of pump and fan

39

Name

Type number

Motor for
discharge
oil pump
Motor for
Vacuum pump

YB280M-4

Voltag Power
Current
e
(KW)
(A)
(v)
380/660
90
164.3/94.6

Connectio
n

insulatio
n

Manufacturer

/Y

22.6/13.6

/Y

3.0

6.4

380

3.0

6.4

YB90L-2

380

2.2

4.7

YB160M1-2

380/660

11

21.8/12.6

/Y

380

3.7

7.3

Shenyang
motor
factory
Shangxi
motor
factory
Yamusi-lufu
Motor
factory
Yamusi-lufu
Motor
factory
Yamusi-lufu
Motor
factory
Nanyang
motor
factory
USA

YB160M-4

380/660

11

Motor for
blowdowm
oil pump
Motor for
clear water
pump
Motor for
blowdowm
oil pump
Motor for
intermediat
e pump
Motor for
fuel
treating
pump
Motor for
oil-water
separator
Motor for
washing
pump
Motor for
washing and
chemical
water pump
Motor for
filling
water pump
Motor for
fire
protection
pump
Motor for

YB100L-2

380

YB100L-2

MBT160L4

380

16

32

400

30

55

400

1.1

2.7

LS180CMT-T

380

22

41

Y280S-2

380

75

139.3

Y225M-2

380

45

83.9

40

ABB

ALSTHOM

ALSTHOM

ALSTHOM

Wuxi-zhongda
motor
factory

Wuxi-zhongda

circulating
water pump
of gas
turbine
Motor for
fan of
cooling
water tower
Motor for
make-up
pump in
zhangdatang
Motor for
fuel pump
Motor for
vanadium
resistance
pump
Motor for
cooling fan
of turbine
Motor for
auxiliary
lubricating
oil pump
Motor for
emergency
lubricating
oil pump
Motor for
priming
diesel
engine
Motor for
auxiliary
hydraulic
oil pump
Motor for
hydraulic
ratchet pump
Motor for
inertiaseparator

motor
factory

Y315L1-4

380

160

289

ShanghaiWuyi motor
Factory

--

380

30

58

--

Yangzhou?

Y20631

400

15

27.2

ALSTHOM

F80BTV/6FT

400

0.37

1.1

ALSTHOM

ADF132SA

400

30

52

--

ALSTHOM

--

400

30

52

ALSTHOM

D-GNFZE-17122

DC125

7.4

77

--

ALSTHOM

--

DC125

7.36

--

--

--

USA

--

400

15

29

ALSTHOM

5BC79AE10

DC125

1.2

--

USA

--

400

22

--

--

--

ALSTHOM

41

Motor for
pipe pump
Blowdown
pump for
gas turbine
Pump and fan

Washing pump
Filling water
pump
Make-up pump
Fire
protection
pump
Pipe pump
Circulating
water pump
for gas
turbine
Cooling tower
fan
Discharge oil
pump
Discharge oil
vacuum pump
Intermediate
pump
Blowdown oil
pump
Blowdown oil
with water
pump
Clear-water
pump
Fuel treating
pump
Dreg-oil pump

Y132S2-2

380

7.5

15

--

Y802-4

380

0.75

2.0

--

--

The technical specifications of pump and fan


Type
Type
Flow
Pressure
Spee Drive
3
number
(m /h)
(MPa)
d
(r/m
)
NCP8-250
centrifugal
2208
0.7
2945
88TW
TCD110/6
centrifugal
13
4
2935
88WN
8
150QGW20
centrifugal
200
0.3
980
RP-B
0-30
1508-100
centrifugal
160
1
2950 RP-XF

80SG-5030
200S-42

centrifugal

50

0.3

2800

centrifugal

280

0.42

LF-85

Shaft flow

200CYZ63
2X-70A

Self-suction

2731
04
280

Water-cycle

80AYT60B

Manufacturer

ALSTHOM
ALSTHOM
Yangzhou-yatai
pump factory
Wuxi pump
factory

2950

Y132S2
-2
RP-XZ

Shanghai-jinxing
pump factory
Wuxi pump
factory

15210-6

149

RJ-L

0.63

1450

RP-ZX

70

610-8

420

RP-ZX

centrifugal

40

0.39

2900

RP-ZX

IY50-32160
IY50-32125

centrifugal

12.5

0.32

2900

RP-WY

centrifugal

12.5

0.2

2900

RP-WY

Baoding airscrew
factory
Yiwu oil pump
factory
Zibo vacuum pump
factory
Tianjin pump
factory
Shanghai-kaili
pump factory
Shanghai-kaili
pump factory

IY50-32160
ROSG1

centrifugal

12.5

0.32

2900

RPWY(s)

centrifugal

2900

Shanghai-kaili
pump factory
U.S.A

OP03/A01
R4/E77N

centrifugal

1750

UTP

MEXCO

42

Fuel oil pump


Vanadium
resistance
pump
Cooling fan
for turbine
Cooling fan
for turbine
and auxiliary
equipment
Fan for block
seal

NSB40
MD9362G159U45/1
VS
HADFE92

centrifugal
centrifugal

2940
930

88FD
88FA

ALSTHOM
ALSTHOM

P
=1234.2Pa
P=442Pa

2950

88TK

ALSTHOM

074SD607

centrifugal

1.81
05

1440

88BT

ALSTHOM

4995
type
9-19
type

centrifugal

2281

45mmWC

2900

ADF

ERANCE

centrifugal

2281

45mmWC

2900

ADF

Hefei fan
factory

4.5

centrifugal

The technical specifications of generator


Name
Gas turbine generator
Steam turbine generator
Type number
T190-240
AG220M161
Type
Horizontal air-cooled
Horizontal air-cooled convex
hided pole no-brush
pole no-brush excitation
excitation generator
generator
Rated capacity
48.75MVA
47.625MVA
Rated power factor
0.8
0.85
Rated power
39.00MW
48.481MW
Rated voltage
11.00KV
11.00KV
Rated current
2559A
2500A
Rated frequency
50HZ
50HZ
Rated speed
3000r/min
1500r/min
Maximal rated speed
3600r/min
1800r/min
Stage number
2
4
Phase number
3
3
Connection type
Y
Y
Insulation grade
F
F
Standard
IEC
Protection grade
IP55
IP54
Cooling type
Air-cooled (water
IC8AIW7(CACW air-cooled)
cooler)
Maximal temperature for stator
125 (inbuilt)
125
Maximal temperature for rotor
130(adjustable and
130
electronic type)
Inlet temperature for cooling
34
23
water
Outlet temperature for cooling
38.3
water

43

Cooling water flow


Inlet temperature for cooling
air
Outlet temperature for cooling
air
Cooling air flow
Cooler number
Direction

140.0m3/h
72.1
40.0
19.6 m3/s
2
Clockwise
2. Operation performance
Gas turbine
0.53
0.00421

2
Clockwise

Name
Steam turbine
short circuit ratio
0.5
Signal phase stator
resistance(75)
Signal phase rotor
0.44918
resistance(75)
Signal phase stator
0.00696
resistance(20)
Signal phase rotor
0.1873
resistance(20)
Isochronous XD un-saturation
217.8%
reactance
Transient XD un-saturation
27.4%
reactance
Transient XD saturation
26.5%
27%
reactance
hypo- transient XD un17.8%
saturation reactance
hypo- transient XD saturation
15.3%
16%
reactance
Converse X1 un-saturation
19%
reactance
Converse X1 saturation reactance
16.3%
Other order X0
7.8%
Section 2: The technical specifications of exciter
Gas turbine
Steam turbine
Name
Name
Exciter
Exciter
Permanent magnet motor
Type number
TKJ70-10
Type number
MAJ51M20
Type number
55/44
Number
152565
Number
Frequency
275Hz
Rated power
153.4KW
Rated power
106kW(DC
Rated voltage
240V
)
Rated voltage
274V
Rated voltage
163V(DC)
Input voltage
205V(AC)
Rated current
560A
Rated current
700A
Rated current
18.2A(AC)

44

Phase number
Rated frequency
Pole number
Insulation grade

5
200HZ

Phase number
3
Phase number
1
Rated frequency
150HZ
Pole number
12
F
Insulation
F
grade
Standard
IEC34
Standard
IEC34
The highest
120
The highest
120
temperature raise
temperature
raise
Section 3: The technical specifications for suitable transformer
of #1 gas turbine
Name
suitable transformer of #1 gas turbine
Type number
NOA43325
Type
Dry type (epoxy colophony)
Rated capacity
400KVA
Rated voltage
11.0KV/380V
Connection group
DYn11
Short circuit impedance
Ud%=5%
Section 4: The technical specifications for auxiliary equipment
of generator
Outlet switch for generator 52G
Gas turbine (-Q400)
Steam turbine
Type number
FP17-40G
Type number
FP17-40G
Type
SF6 small car
Type
SF6 small car
Rated voltage(KV)
17.5
Rated voltage(KV)
17.5
Rated current(A)
2650
Rated current(A)
2650
Rated emergency current(KA)
44
Rated emergency current(KA)
44
High voltage side fuse for self- transformer
#1 gas turbine(-F40)
Steam turbine
Type number
MFC64210
Type number
Have no this equipment
Rated voltage(KV)
24
Rated voltage(KV)
Rated current(A)
32
Rated current(A)
Low voltage side fuse for self- transformer
#1 gas turbine(-Q01)
Steam turbine
Type number
D630
Type number
Have no this equipment
Rated voltage(KV)
690
Rated voltage(KV)
Rated current(A)
630
Rated current(A)
Standard
IEC947-2
Standard
Three phase three-winding for low voltage side of gas turbine
transformer
Gas turbine (-T41)
Steam turbine
Type number
UR2/18
Type number

45

Transformation ratio

11000/1.732,100/1.732,100/1.732

Transformation
ratio
Rated capacity(VA)
Precision

11000/1.732
100/1.732
50
0.5

Rated capacity(VA)
50
Precision
0.5
Arrester for generator outlet
Gas turbine (-F40)
Steam turbine
Type
Related voltage
Type
resistor
Rated voltage(KV)
12
Rated voltage(KV)
High current impulse(A)
150
High current impulse(A)
Standard
IEC99.1/IEC99.1A
Standard
High voltage fuse for generator outlet
Gas turbine (-F33)
Steam turbine
Type number
C64
Type number
Rated voltage(KV)
24
Rated voltage(KV)
Rated current(A)
6.3
Rated current(A)
Neutral point grounding resistance for generator
Gas turbine(-R30)
Steam turbine
Type
stainless steel
Type
stainless steel
grid
grid
Resistance value
635
Resistance value
635
Allowable working
2
Allowable working
2
current(A)
current(A)
30s allowable current(A)
10
10s allowable
10
current(A)
Three-winding and three-loop current inductor for generator outlet
Gas turbine (-T32)
Steam turbine
Type
ZRM533
Type
Transformation
3000A/1A
Transformat
3000A/1A
ratio
ion ratio
Rated capacity (VA)
10VA(differential loop)
Rated
10VA(differential loop)
precision 5P20
capacity
precision 5P20
10VA(stand-by loop) precision
(VA)
30VA(metrical loop)
5P20
precision0.5
30VA(metrical loop)
precision0.5
Three-winding and three-loop for generator neutral point (CT)
Gas turbine (-T31)
Steam turbine
Type
IRN17/2
Type
Transformation
3000A/1A
Transformat
3000A/1A
ratio
ion ratio
Rated capacity (VA)
10VA(differential loop)
Rated
10VA(differential loop)
precision 5P20
capacity
precision 5P20

46

15VA(stand-by loop) precision


5P20
Remain a set of stand-by loop

(VA)

15VA(protection loop)
Precision5P10
10VA(differential loop)
precision 5P20

The single loop for generator neutral point (CT)


Gas turbine (-T301)

Steam turbine
Type
Transformation ratio

Type
Transformation
5A/1A
ratio
Rated capacity (VA)
10
Rated capacity(VA)
Precision
1.0
Precision
Capacitor group for generator outlet
Gas turbine (-C40)
Steam turbine
Type
Single phase, stationary,
Type number
indoor
Rated voltage(KV)
15
Rated voltage(KV)
Capacity (F)
0.25
Capacity (F)
Standard
IEC358
Standard
The transformer for exciter of generator
Gas turbine (-T330)
Steam turbine
Type
Single phase, dry type
Type
Rated voltage(KV)
11000/2180V
Rated voltage(KV)
Rated capacity (KVA)
26
Rated capacity (KVA)
Short circuit impedance Ud
3.2%
Short circuit impedance Ud

5A/1A
10
5P10

EHS152
15.2
0.25

A set of
permanent
magnet
motor was
fixed

Three-phase and two winding for corresponding voltage of generator


(PT)
Gas turbine (-T35)
Steam turbine
Type
VKM23/3
Type
EHS152
Transformation
11000/1.732,100/1.732
Transformation ratio
11000/1.732
ratio
,100/1.732
Rated capacity (VA)
100
Rated capacity(VA)
15
Precision
0.5
Precision
0.5

Secondary side switch for generator PT


Gas turbine (-Q01,-Q02,-Q0.3)
Type number
C2
Type
D32

47

Steam turbine
Type number
Type

C2
D32

Rated voltage(V)
380/415
Rated voltage(V)
400
Rated current(A)
10A
Rated current(A)
10A
Standard
IEC898 IEC947-2
Standard
IEC898 IEC947-2
Single phase and two-winding for protection loop of generator PT
Gas turbine (T34)
Steam turbine
Type number
Type number
Type
VKP24/3
Type
Transformation ratio
11000/1.732, 100/1.732
Transformation ratio
Rated capacity (VA)
15
Rated capacity (VA)
Precision
1/3P
Precision

48

You might also like