ESR metru nou cu posibilitati de calibrare

Indica ESR-ul si la condensatori de 22000 microF


Mai multe detali le gasiti mai jos. Pretul este
210ron(negociabil)
Digital Capacitor/Capacitance ESR IN-Circuit
Inductance Resistance LC Meter+CASE+alkaline
batery 9v
Description:
Measurment Range:
1, R Measuring range: 0.01 to 18 ohms
2, C Measuring range: 0.15u to 3300uF
3, R Accuracy: 5% + 20 milliohms, measuring a dozen capacitive or resistive, ESR is all within the error of
1% +0.01 Europe. No long-term stability test, socalibration is 5%
4, C Accuracy: 72kHz and 3kHz measured simultaneously obtain two capacitance value. Small
capacitance error is about 1% error. As the volume increases, the error becomes large.
The relative error is expressed as 3kHz capacity error can be expressed as 0.05 + C/300,
72k electrolytic 0.05 + C/15, where C is measured in uF, if the error is a high-Q capacitors smaller
Capacity of the error becomes large. 6kHz capacitance measurement range 3uF to 300uF,
72kH range 0.15uF to 20uF.
How to use:
The first row shows the ESR screen, the display character "R".
The second line screen display auxiliary parameter of the measured element, the display character has 6
kinds, respectively is C, D, X, Y, Z, Vc, J0.
Use the K key to switch the menu, in the "ESR", "Vc" J0 calibration calibration "," the three menu to switch
between.
Boot into the "ESR" menu, use the K key to switch auxiliary parameters, can be switched in C, D, X, Y, Z
among the 5 parameters.
The C parameter is the capacity of the capacitors, a total of two, first is 72kHz square wave measured,
second is 3kHz square wave measured
The D parameter is zero DC, with two parameters, first are zero zero time values, second is the zero drift
zero moment to moment.Debugging ESR table.
The X parameter is 72kHz under X axis measuring value, there are two parameters, first are zero time
values, second is the measurement of relative value (i.e. deducted zero value and DC drift).Debugging ESR
table.
The Y parameter is 72kHz under y axis measuring value, there are two parameters, first are zero time values,
second is the measurement of relative value (i.e. deducted zero value and DC drift).Debugging ESR table.
The Z parameter is 3kHz under y axis measuring value, there are two parameters, first are zero time values,
second is the measurement of relative value (i.e. deducted zero value and DC drift).Debugging ESR table.
Measurements should be carried out before the short circuit reset.3 cm long thick copper wire short circuit,
and then press the C key.Reset the data will be stored to the MCU internal EEPROM.There may be zero
drift, use short time review recommendations, if not zero should be clear treatment
Calibration

Set two parameters, Vc and J0.The Vc parameter should be about 525, J0 is about 13.Before calibration, if
J0 is more than 40 of the values or -30 values below, please J0 set to 0, then the following calibration.
1, use 3cm thick copper wire for short circuit to clear, this is the first step, is the premise.
2, amplitude calibration: access to a 15 to 20 ohm resistor color ring.Press the Menu button, switch to the Vc
calibration menu, use "C" and "K" or Vc value, the R value displayed as close as possible and the resistance
being measured.
3, phase calibration: 0.47uF/630V CBB capacitor to known ESR (ESR is in commonly 20 to 30
MOhm).Press the M button, switch to the J0 calibration menu, use "C" and "K" or J0 value, the R value
displayed as close as possible to the ESR and capacitor.
4, hold down the M key for 3 seconds, then release, will automatically save parameters, prompt on the
screen.
5, and then press the M key, return to the ESR state measurement
ESR metrul este nou i calibrat din fabrica. Se vinde cu cabluri,borne si o baterie alkalina grundig de
9v,noua(vezi poze