You are on page 1of 176

Antenna & Subsystem

Product Catalog

Ver2.1 Dec 2012

Antenna & Subsystem


Contents
Legal Disclaimer.............3
Introduction.............4
Product Selection Guide............................6
A. BTS Antenna............11

800/900/1800/1900/2000 V-Pol.........................11
800/900 X-Pol....................................................15
1800/1900/2000/2600 X-Pol.........................................28
800/900-1800/1900/2000/2600 XX-Pol.....................................................37
800/900-1800/1900/2000/2600 XXX-Pol.................................51
800/900-1800/1900/2000/2600 XXXX-Pol...................56
B. Repeater/Microcell Antenna..................57
C. Indoor Antenna............................................................................................................64
D. RET System.................................................................................................................70
E. RF Products...............................................................................................................75

Tower Mounted Amplifier..........................................................................................75


Combiner...............................................................................................................112
Filter and Duplexer.................................................................................................130
Project Components..............................................................................................145
POI........................................................................................................................166
Mounting Kits..............................................................................170

www.comba-telecom.com

Antenna & Subsystem


Legal Disclaimer
Comba Telecom Limited retains copyright on all the text, graphics and trademarks displayed on this paper. All
the text, graphics and trademarks displayed on this paper are owned by Comba Telecom Limited and used
under licence by Comba affiliates.

You may print copies of the information on this paper for your personal use and store the files on your
computer for personal use. You may not distribute text or graphics to others without the express written
consent of Comba Telecom Limited and Comba affiliates. Also, you may not, without our permission, copy
and distribute this information on any other server, or modify or reuse text or graphics on this or any another
system.

No reproduction of any part of the paper may be sold or distributed for commercial gain, nor shall it be
modified or incorporated in any other work, publication or site, whether in hard copy or electronic format,
including postings to any other site. Comba Telecom Limited reserves all other rights.

The information on this paper has been included in good faith and is for general purposes only. It should not
be relied upon for any specific purpose and no representation or warranty is given as regards its accuracy or
completeness.

No information on this paper shall constitute an invitation to invest in Comba Telecom Limited or any of
its affiliates. Neither Comba Telecom Limited and Comba affiliates, nor their or their affiliates' officers,
employees or agents shall be liable for any loss, damage or expense arising out of any access to or use
of this paper or any site linked to it, including, without limitation, any loss of profit, indirect, incidental or
consequential loss.

www.comba-telecom.com

Antenna & Subsystem


Introduction
Comba Telecom is a leading supplier of infrastructure and wireless enhancement solutions to mobile
operators and enterprises to enhance and extend their wireless communications networks. Established in
1997, and listed on the Hong Kong Stock Exchange in 2003, it has grown to become a global supplier with its
extensive distribution network and 60+ offices covering Asia Pacific, EMEA (Europe, Middle East and Africa),
and the Americas.
With a highly regarded team of research and development engineers and its state-of-the-art design tools
and testing equipment, Comba is able to provide its innovative patented designs and yet cost-effective
products to the customers. Its largest microwave anechoic chambers in the region, is located in Guangzhou,
China, has been used by many customers around the world as an accredited testing facility for antenna
performance benchmarking.
Comba Antenna & Subsystem Business Unit offers full range of wireless antenna and RF products for cellular
systems, which include:
Base Station Antenna
Repeater/Microcell Antenna
Indoor Antenna
Remote Electrical Tilt System
RF products
TMA System
Comba is committed to quality consistency and environmental protection and is ISO9001 and ISO14001
certified. With its highly efficiency production lines in China and strict process control system, Combas
manufacturing facility is able to deliver high volume products with consistent quality.

Comba manufacturing facility in Guangzhou, China

Comba R&D Center in Guangzhou, China

www.comba-telecom.com

Antenna & Subsystem


Introduction

Antenna production facility

Summitek PIM test equipment and Microwave anechoic chamber

www.comba-telecom.com

Product Selection Guide


A: BTS antenna
Model Number

Freq Range (MHz)

H-HPBW

Pol.

()

Gain (dBi)

Electrical tilt

Launch

()

Time

Page

1) 800/900/1800/1900/2000 V-Pol
ODP-065V17BXX

806-960

65

V-Pol

17.2

FET (0,6)

Available

11

ODP-065V18Bxx

806-960

65

V-Pol

18.2

FET (0,6)

Available

12

ODP-090V17Bxx

806-960

90

V-Pol

17.0

FET (0,6)

Available

13

ODP-065V18Kxx

1710-2170

65

V-Pol

18.0

FET (0,6)

Available

14

ODP-065R15Bxx

806-960

65

X-Pol

15.1

FET (0,6)

Available

15

ODP-065R17Bxx

806-960

65

X-Pol

17.1

FET (0,6)

Available

16

ODP-065R18Bxx

806-960

65

X-Pol

18.0

FET (0,6)

Available

17

ODP-065R18EXX(JS)

790-960

65

X-Pol

18.0

FET (0,6)

Available

18

ODP-090R17Bxx

806-960

90

X-Pol

17.1

FET (0,6)

Available

19

ODV-032R20E-G

790-960

32

X-Pol

19.3

VET(0-10)

2013 Q1

20

ODV-065R15E-G

790-960

65

X-Pol

15.2

VET(0-20)

2013 Q1

21

ODV-065R17E-G

790-960

65

X-Pol

16.6

VET(0-10)

2013 Q1

22

ODV-065R18E-G

790-960

65

X-Pol

17.5

VET(0-12)

2013 Q1

23

ODV-065R15B

806-960

65

X-Pol

15.5

VET (0-14)

Available

24

ODV-065R17B

806-960

65

X-Pol

17.0

VET (0-10)

Available

25

ODV-065R18B

806-960

65

X-Pol

17.6

VET (0-8)

Available

26

ODV-090R17E-G

790-960

90

X-Pol

16.5

VET (0-12)

2013 Q1

27

2) 800/900 X-Pol

3) 1800/1900/2000/2600 X-Pol
ODP-065R15Kxx-G

1710-2170

65

X-Pol

15.3

FET (0,6)

Available

28

ODP-065R18Kxx-G

1710-2170

65

X-Pol

18.0

FET (0,6)

Available

29

ODV-032R21K-G

1710-2170

32

X-Pol

20.8

VET (0-10)

Available

30

ODV-065R15K-G

1710-2170

65

X-Pol

15.3

VET (0-20)

2013 Q1

31

ODV-065R18K-G

1710-2170

65

X-Pol

18.0

VET (0-10)

Available

32

ODV-065R18K

1710-2170

65

X-Pol

18.0

VET (0-10)

Available

33

ODV-065R18J-G

1710-2690

65

X-Pol

18.0

VET (0-12)

2013 Q1

34

ODV-065R18J

1710-2690

65

X-Pol

18.0

VET (0-12)

Available

35

ODV-090R17K-G

1710-2170

90

X-Pol

16.5

VET (0-10)

2013 Q1

36

806-960/1710-2170

65

XX-Pol

16.7/17.5

FET (0,6)

Available

37

790-960/1710-2170

65

XX-Pol

14.0/16.8

VET

2013 Q1

4) 800/900-1800/1900/2000/2600 XX-Pol
ODP-065R17B18Kxxyy
ODV-065R14E17K-G

ODV-065R15E18K-G

ODV-065R17E18K-G

ODV-065R17E18K

ODV-065R18EK-G

(0-20/0-10)
790-960/1710-2170

XX-Pol

65

15.0/17.7

VET

38

2013 Q1

39

Available

40

Available

41

2013 Q1

42

(0-20/0-10)
790-960/1710-2170

XX-Pol

65

16.7/17.7

VET
(0-10/0-10)

790-960/1710-2170

XX-Pol

65

16.7/17.7

VET
(0-10/0-10)

790-960/1710-2170

XX-Pol

65

17.3/17.7

VET
(0-10/0-10)

ODV-065R18EK

ODV-065R15E18J-G

ODV-065R17E18J-G

ODV-065R18EJ-G

ODV2-065R18K-G

ODV2-065R18K

790-960/1710-2170

XX-Pol

65

17.3/17.7

VET

2013 Q1

43

2013 Q1

44

2013 Q1

45

2013 Q1

46

Available

47

Available

48

(0-10/0-10)
790-960/1710-2690

XX-Pol

65

14.8/18.0

VET
(0-14/0-10)

790-960/1710-2690

XX-Pol

65

16.3/18.0

VET
(0-10/0-10)

790-960/1710-2690

XX-Pol

65

17.3/18.0

VET
(0-10/0-10)

1710-2170/1710-2170

65

XX-Pol

18.0/18.0

VET
(0-10/0-10)

1710-2170/1710-2170

65

XX-Pol

18.0/18.0

VET
(0-10/0-10)

ODV2-065R18J-G

1710-2690/1710-2690

65

XX-Pol

17.7/17.7

0-12/0-12

2013 Q1

49

ODV2-065R18J

1710-2690/1710-2690

65

XX-Pol

17.7/17.7

0-12/0-12

Available

50

65

XXX-Pol

15/15.5/

VET(0-14/

Available

15.5

0-12/0-12)

17.5/17.5/

VET(0-10/

17.7

0-10/0-10)

15.0/17.7/

VET(0-14/

17.7

0-12/0-12)

16.3/16.3/

VET(0-10/

16.8

0-12/0-12)

17.3/17.1/

VET(0-10/

17.6

0-12/0-12)

2x15.0/

VET 2x

2x17.7

( 0-20/0-10)

5) 800/900-1800/1900/2000/2600 XXX-Pol
ODV-065R15B15J15J

ODV-065R18EKK-G

ODV-065R15E18J18J-G

ODV-065R17EJJ-G

ODV-065R18EJJ-G

806-960/1710-2690/
1710-2690
790-960/1710-2170

790-960/2x1710-2690

790-960/2x1710-2690

790-960/2x1710-2690

XX-Pol

65

XXX-Pol

65

XXX-Pol

65

XXX-Pol

65

2013 Q1

2013 Q1

2013 Q1

2013 Q1

51

52

53

54

55

6) 800/900-1800/1900/2000/2600 XXXX-Pol
ODV2-065R15E18K-G

2 x 790-960 /

65

XXXX-Pol

2 x 1710-2170

2013 Q1

56

B: Repeater/Microcell Antenna
Model Number

Freq Range(MHz)

H-HPBW ()

Polarization

Gain (dBi)

Page

ODM-030V16K0-2

1710-2170

30

V-Pol

13.5

57

ODM-030V18B0

824-960

30

V-Pol

18.0

58

ODM-075V11N0

806-960/1710-2500

75

V-Pol

9.7/11.0

59

ODP-030V20K0

1710-2170

30

V-Pol

20.0

60

ODP-032V15N

790-960/1710-2690

32

V-Pol

11.0/15.0

61

OYI-040V12K0-2

1710-2170

40

V-Pol

12.5

62

OYI-040V13B0-2

806-960

40

V-Pol

13

63

C: Indoor Antenna
Model Number

Freq Range(MHz)

H-HPBW

Polarization

()

Gain (dBi)

Mounting

Page

IWH-065V07N0

670-960/1710-2700

65

V-Pol

4.5/7.0

Wall mount

64

IWH-090V08N0-5

806-960/1710-2700

90

V-Pol

7.0/8.0

Wall mount

65

IXD-120V06N0-3

806-960/1710-2500

120

V-Pol

6.0/6.0

ceiling mount

66

IXD-360V03NN(05)

670-960/1710-2700

360

V-Pol

2.0/4.0

ceiling mount

67

IXD-360V03NN(U)

806-960/1710-2700

360

V-Pol

2.0/4.0

ceiling mount

68

IXD-360VH03NT

806-960/1710-2700

360

V-Pol & H-Pol

2.0/4.0

ceiling mount

69

D: RET system
Model Number

Product Description

Page

00-KX02(yy) AISG Cable

AISG Control Cable (yy=cable length in meter)

70

RCU-003

Remote Control Unit AISG v1.1 Compliant

71

RCU-V5002

Remote Control Unit AISG v2.0 Compliant

72

CCU-001AG CCU-003AG

Central Control Unit Fully compliant with AISG issue 1.1 & 2.0

73

E: RF product
Model Number

Product Description

Launch

Page

time
1) Tower Mounted Amplifier
TA-C12FS03

Single TMA, 824-849MHz/869-894MHz, 12dB Gain, CWA alarming

Available

75

TA-C12FDA-A

Dual TMA, 824-849MHz/869-894MHz, 12dB Gain, AISG 2.0 compliant

Available

77

TA-G12FS02

Single TMA, 890-915MHz/935-960MHz, 12dB Gain, CWA alarming

Available

79

TA-E12FS

Single TMA, 880-915MHz/925-960MHz, 12dB Gain, CWA alarming

Available

81

TA-E12FDA-A

Dual TMA, 880-915MHz/925-960MHz, 12dB Gain, AISG2.0 compliant

Available

83

TA-D12FS

Single TMA, 1710-1785MHz/1805-1880MHz, 12dB Gain, CWA alarming

Available

85

TA-D12FD-03

Dual TMA, 1710-1785MHz/1805-1880MHz, 12dB Gain, CWA alarming

Available

87

TA-D12FDA-A

Dual TMA, 1710-1785MHz/1805-1880MHz, 12dB Gain, AIS2.0 compliant

Available

89

TA-D12FDA

Dual TMA, 1710-1785MHz/1805-1880MHz, 12dB Gain, AISG1.1 compliant

Available

91

TA-P12FDA

Dual TMA, 1850-1910MHz/1930-1990MHz, 12dB Gain, AISG1.1 compliant

Available

93

TA-P12FDA-A

Dual TMA, 1850-1910MHz/1930-1990MHz, 12dB Gain, AISG2.0 compliant

Available

95

TA-W12FDA-A

Dual TMA, 1920-1980MHz/2110-2170MHz, 12dB Gain, AISG2.0 compliant

Available

97

Dual

2012 Q4

99

TA-W12FDA-02

TMA,

1920-1980MHz/2110-2170MHz,

12dB

Gain,

AISG1.1

compliant, available to upgrade software to compliance AISG2.0

TA-W12FD

Dual TMA, 1920-1980MHz/2110-2170MHz, CWA alarming, 12dB Gain

Available

101

TA-Y12FDA-A

Dual TMA, 2500-2700MHz/2620-2690MHz, AISG2.0 compliant

Available

103

TA-C12G12FDA-A

Dual band TMA, LTE800 MHz and 900MHz full band, 2 input 2 output ports,

Available

105

Product Available
BT-R1/R2

Bias Tee, 698-2700MHz

Available

108

BT-R1S1/R2S2

Smart Bias Tee, 698-2700MHz, AISG2.0 compliant

Available

109

PDM-001B/003B

Power distribution unit

Available

110

CM-BK2-IN1B

Indoor diplexer, 800-960/1710-2170MHz, 100W, N, Single unit

Available

112

CM-BDW2-IN1

Indoor diplexer, 800-960&1710-1880/1920-2170MHz, 200W, N, Single

Available

113

Available

114

2) Combiner

unit
CM-BDW3-IN1B

Indoor triplexer, 800-960/1710-1880/1920-2170MHz, 100W, N, Single


unit

CM-DW2-IN1

Indoor diplexer, 1710-1880/1920-2170MHz, 100W, N, Single unit

Available

115

CM-KY2-IN1

Indoor diplexer, 1710-2170/2400-2700MHz, 250W, N, Single unit

Available

116

CM-ML2-IN2

Indoor diplexer, 50-2200/2400-2500MHz, 200W, N, Single unit

Available

117

CM-BK2(D)-ODXX

Outdoor diplexer, 806-960/1710-2170MHz, 250W, Din, SingleDouble

Available

118

Outdoor diplexer, 1710-1880/1920-2170MHz, 250W, Din, SingleDouble Available

119

unit
CM-DW2(D)-ODXX

unit
CM-BDW3(D)-ODXX

Outdoor triplexer, 806-960/1710-1880/1920-2170MHz, 250W, Din, Single

Available

120

Doubleunit
CM-KY2-OD4B

Outdoor diplexer, 1710-2170/2300-2700MHz, 250W, Din, Single unit

Available

121

CM-BKY3-OD6

Outdoor triplexer, 806-960/1710-2170/2300-2690MHz, 250W, Din, Single

Available

122

combiner,

Available

123

Outdoor diplexer, 806-960 & 1710-2170/2300-2700MHz, 250W, Din,

Available

124

1850-1910&1930-1990/1710-1755/2110-2155MHz,

Available

125

Outdoor diplexer, 380-960/1710-2700MHz, 250W, Din, SingleDouble

2013 Q1

126

2013 Q1

127

2013 Q1

128

2013 Q1

129

unit
CM-BDWY4-OD8

Outdoor

Quad-band

806-960/1710-1880/1920-2170/2500-2690MHz,
250W, Din, Single unit
CM-MY2-OD4

Single unit
CM-PK2-OD4

Outdoor

diplexer,

250W, Din,
Single unit
CM-FK2(D)-ODX

unit
CM-FDW3(D)-ODX

Outdoor triplexer, 380-960/1710-1880/1920-2170MHz, 250W, Din, Single


Doubleunit
Outdoor triplexer, 380-960/1710-2170/2300-2690MHz, 250W, Din, Single

CM-FKY3(D)-ODX
CM-FDWY4(D)-ODX

Doubleunit
Outdoor

triplexer,

380-960/1710-1880/1920-2170/2500-2690MHz,

250W, Din, SingleDoubleunit

3) Filters and duplexer


FP-G75-D01

Band-pass Filter, 885-915/930-960MHz

Available

130

FP-C59-D01

Band-pass Filter, 824-837.5/869-882.5MHz

Available

131

FP-G1216-D02(907-960)

Band-pass Filter, 907-960MHz

Available

132

FP-G1216-D01(903-960)

Band-pass Filter, 903-960MHz

Available

133

FP-G15D-OD01

Band-pass Filter, 900.1-907/945.1-952MHz

Available

134

FP-C22-D01

Band-pass Filter, 824-846.5/869-891.5MHz

Available

136

FP-C60-D01

Band-pass Filter, 824-884MHz

Available

137

DU-E7030-D01

EGSM900 Duplexer, 885-915/ 930-960MHz

Available

138

DU-D8005-D03

GSM1800 Duplexer, 1710-1785/ 1805-1880MHz

Available

139

FP-G11D-OD1

Band-pass Filter, 902.1-913.1/947.1-958.1MHz

Available

140

FP-G26D-OD1

Band-pass Filter, 890.1-903.7/935.1-948.7MHz

Available

142

COM-BD21ODN3

2x3dB Hybrid Coupler Terminated with 100W low PIM Load, 698-2700MHz

Available

145

HC-R-OD150L

Indoor/Outdoor wideband hybrid coupler, 698-2700MHz, 150W, DIN-F

Available

147

HC-R-ON150L

Indoor/Outdoor wideband hybrid coupler, 698-2700MHz, 150W, N-F

Available

148

HC-x-D200L, HC-x-N200L

Indoor wideband hybrid coupler, 800-2500MHz, 200W, N-F, DIN-F

Available

149

Available

150

4) Project components

HC-R4-ON60L
HC-R4-OD60L

Indoor/Outdoor wideband hybrid coupler, 698-2700MHz, 60W, N-F, DIN-F

PS-Rx-OD700C

PS-Rx-ON300C

PS-Rx-ON50M

PS-Nx-D700C

PS-Nx-N50M

PS-Nx-N200C

PS-Zx-N200C
CO-Rxx-ON200C
CO-Bxx-D200C
CO-Dxx-D200C

Indoor/Outdoor

wideband

power

splitter,

2way/3Way/4Way,

Available

151

power

splitter,

2way/3Way/4Way,

Available

152

power

splitter,

2way/3Way/4Way,

Available

153

Indoor wideband power splitter, 2way/3Way/4Way, 800-2500MHz, 700W,

Available

154

Available

155

Available

156

Available

157

Available

158

Available

159

698-2700MHz, 700W, DIN-F


Indoor/Outdoor

wideband

698-2700MHz, 300W, N-F


Indoor/Outdoor

wideband

698-2700MHz, 50W, N-F

Din-F
Indoor wideband power splitter, 2way/3Way/4Way, 800-2500MHz, 50W,
N-F
Indoor wideband power splitter, 2way/3Way/4Way, 800-2500MHz, 200W,
N-F
Indoor wideband power splitter, 2way/3Way/4Way, 824 960 / 1710
2700 MHz, 200W, N-F
Indoor/Outdoor coupler, 6/10/15/20/30/40dB, 698-2700MHz, 200W, N-F
Indoor coupler, 30/40/55dB, 820-960/1700-1900MHz, 200W, DIN-F
coupler,

5/6/7/8/10/13/15/20/30/40dB,

Available

160

coupler,

5/6/7/8/10/13/15/20/30/40dB,

Available

162

DC-Nxx-D200M

Indoor directional coupler, 6/10/15/20dB, 800-2500MHz, 200W, DIN-F,

Available

164

DC-Nxx-N200M

N-F

DC-Nxx-N200C

Indoor directional coupler, 6/10/15/20dB, 800-2500MHz, 200W, N-F

Available

165

Singapore POI: 1x iDEN, 1x EGSM, 2x GSM900, 3x GSM1800, 3x

Available

166

Available

167

Available

168

Available

169

DC-Rxx-OD200M

DC-Rxx-ON200M

Indoor/Outdoor

directional

698-2700MHz, 200W, DIN-F


Indoor/Outdoor

directional

698-2700MHz, 200W, N-F

5) POI
POI-TDA2ODN4SG

UMTS2100 multi-band combiner


POI-TDH2IDN1HK

HK Duplex POI: 4xGSM900,6xGSM1800,4xUMTS,3xLTE2.6G multi-band


combiner

POI-TSJ2IDN1HK-TX

HK Simplex POI-Tx unit: 6xGSM900 Tx, 6xGSM1800 Tx, 4xUMTS


Tx,3xLTE2.6G Tx/Rx

POI-TSJ2IDN1HK-RX

HK Simplex POI-Rx unit: 6xGSM900 Tx, 6xGSM1800 Tx, 4xUMTS


Tx,3xLTE2.6G Tx/Rx

10

Outdoor Directional Panel Antenna


ODP-065V17Bxx

VPol, 806-960MHz, 65, 17.2dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Fixed(Optional)
First Upper Sidelobe Suppression
Front-To-Back Ratio
VSWR
3rd Order Intermodulation @ 2x43 dBm
Maximum Power
Impedance
Lightning Protection

MHz

806-880

880-960
Vertical

dBi
deg
deg
deg
dB
dB

17.0

17.2
65
10
0, 6
> 18
> 28
1.5:1
< -150
500
100
50
Direct Ground

dBc
W

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

C
%
km/h (mph)
mm (in)
kg (lb)

2095x265x141 (76.2x10.4x5.5)
11 (24.3)
17.5 (38.6)
UV Resistant PVC, Light Grey
00-ZJ10(12)
7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
2270375 280 (89.4x14.7x11.0)
23 (50.7)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

820MHz @ 0o

870MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

11

960MHz @ 0o

Issued: Nov12
Control: 3-0-2
1/1

Outdoor Directional Panel Antenna


ODP-065V18Bxx

VPol, 806-960MHz, 65, 18.2dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Fixed (Optional)
First Upper Sidelobe Suppression
Front-To-Back Ratio
VSWR
3rd Order Intermodulation @ 2x43 dBm
Maximum Power
Impedance
Lightning Protection

MHz

806-896

870-960
Vertical

dBi
deg
deg
deg
dB
dB

17.7

18.2
65
6.5
0, 6
> 18
> 27
1.4:1
< -150
500
100
50
Direct Ground

dBc
W

Mechanical
Dimensions, HxWxD
Weight, without Mounting kit
Weight, with Mounting kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

2615x265x141(102.7x10.4x5.5)
16(35.3)
22.5(49.6)
UV Resistant PVC, Light Grey
00-ZJ10(08)
7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
2915x375x280(114.5x14.7x10.9)
28(61.8)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

824MHz @ 0o

915MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

12

960MHz @ 0o

Issued: Nov12
Control: 3-1-4
1/1

Outdoor Directional Panel Antenna


ODP-090V17Bxx

VPol, 806-960MHz, 90, 17.0dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Fixed (Optional)
First Upper Sidelobe Suppression
Front-To-Back Ratio
VSWR
3rd Order Intermodulation @ 2x43 dBm
Maximum Power
Impedance
Lightning Protection

MHz

806-896

870-960
Vertical

dBi
deg
deg
deg
dB
dB

16.7

17.0
90
7.5
0, 6
> 16
> 25
1.4:1
< -150
500
50
Direct Ground

dBc
W

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

2615x265x145 (102.8x10.4x5.7)
15 (33.1)
20 (44.1)
UV Resistant PVC, Light Grey
00-ZJ10(08)
7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
2915x375x280 (114.8x14.7x11.0)
27 (59.5)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

824MHz @ 0o

870MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

13

960MHz @ 0o

Issued: Nov12
Control: 3-1-3
1/1

Outdoor Directional Panel Antenna


ODP-065V18Kxx

VPol, 1710-2170MHz, 65, 18.0dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Fixed (Optional)
First Upper Sidelobe Suppression
Front-To-Back Ratio
VSWR
3rd Order Intermodulation @ 2x43 dBm
Maximum Power Per Port
Impedance
Lightning Protection

MHz

1710-1880

dBi
deg
deg
deg
dB
dB

17.6

dBc
W

1850-1990
Vertical
17.8
65
6.5
0, 6
> 18
> 28
1.5:1
< -150
300
50
Direct Ground

1920-2170
18.0

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1310x173x81 (51.5x6.8x3.1)
5.5 (12.1)
7 (15.4)
UV Resistant PVC, Light Grey
SJA-B-14C(10)
7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
1435x230x210 (56.5x9.1x8.3)
9.2 (20.3)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz @ 0o

1850MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

14

2170MHz @ 0o

Issued: Nov12
Control: 3-1-3
1/1

Outdoor Directional Panel Antenna


ODP-065R15Bxx

XPol, 806-960MHz, 65, 15.1dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Fixed (Optional)
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power Per Port
Impedance
Lightning Protection

MHz

806-896

870-960
45

dBi
deg
deg
deg
dB
dB
dB

14.6

15.1
65

14

13
0, 6
> 15
> 25
> 17
1.4:1
> 30
< -150
500
100
50
Direct Ground

dB
dBc
W

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1315x265x141 (51.6x10.4x5.6)
9.5 (20.9)
15.5 (34.2)
UV Resistant PVC, Light Grey
SJA-B-12R(16)
2x7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
1610x375x275 (63.4x14.8x10.8)
18.3 (40.3)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
Pattern

Horizontal
Pattern

824MHz @ 0o

915MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

15

960MHz @ 0o

Issued: Nov12
Control: 3-1-3
1/1

Outdoor Directional Panel Antenna


ODP-065R17Bxx

XPol, 806-960MHz, 65, 17.1dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Fixed (Optional)
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

806-896

870-960
45

dBi
deg
deg
deg
dB
dB
dB

16.7

17.1
65
9.8
0, 6
> 18
> 25
> 17
1.4:1
> 30
< -150
500
100
50
Direct Ground

dB
dBc
W

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1935x265x141 (76.1x10.4x5.6)
13.8 (30.4)
19.8 (43.7)
UV Resistant PVC, Light Grey
00-ZJ10(12)
2x7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
2270x375x280 (89.4x14.8x11.0)
26.5 (58.4)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

870MHz @0o

915MHz @0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

16

960MHz @0o

Issued: Nov12
Control: 3-1-3
1/1

Outdoor Directional Panel Antenna


ODP-065R18Bxx

XPol, 806-960MHz, 65, 18dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Fixed (Optional)
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

806-896

870-960
45

dBi
deg
deg
deg
dB
dB
dB

17.8

18.0
65
7
0, 6
> 18
> 25
> 17
1.5:1
> 30
< -150
500
100
50
Direct Ground

dB
dBc
W

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

2615x265x141 (102.7x10.4x5.6)
18.5 (40.8)
24.0 (52.9)
UV Resistant PVC, Light Grey
00-ZJ10(08)
2x7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
2895x375x265 (114.0x14.8x10.4)
30.7 (67.7)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

824MHz @ 0o

915MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

17

960MHz @ 0o

Issued: Nov12
Control: 3-1-3
1/1

Outdoor Directional Panel Antenna


ODP-065R18Exx(JS)

XPol, 790-960MHz, 65, 18dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Fixed(Optional)
First Upper Sidelobe Suppression
Front-To-Back Ratio
VSWR
Isolation Between Ports
Cross-polar Discrimination @ 0o
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

790-896

870-960
45

dBi
deg
deg
deg
dB
dB

17.6

18.0
65
7
0, 6
> 18
> 25
1.5:1
> 30
> 17
< -150
500
100
50
Direct Ground

dB
dB
dBc
W

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

2615x265x141 (102.7x10.4x5.6)
19 (41.8)
25.5 (56.2)
Fiberglass, Light grey
00-ZJ10(08)
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
2895x375x265 (114.0x14.8x10.4)
30.7 (67.7)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

824MHz @ 0o

915MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

18

960MHz @ 0o

Issued: Nov12
Control: 3-0-0
1/1

Outdoor Directional Panel Antenna


ODP-090R17Bxx

XPol, 806-960MHz, 90, 17.1dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Fixed(Optional)
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

806-896

870-960
45

dBi
deg
deg
deg
dB
dB
dB

16.7

17.1
90
7
0, 6
> 18
> 25
> 17
1.4:1
> 30
< -150
500
50
Direct Ground

dB
dBc
W

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

2615x265x141 (102.7x10.1x5.6)
18.5 (40.8)
24.0 (52.9)
UV Resistant PVC, Light Grey
00-ZJ10(08)
2x7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
2915x375x280 (114.8x14.8x11.0)
31.5 (69.4)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

824MHz @ 0o

870MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

19

960MHz @ 0o

Issued: Nov12
Control: 3-1-1
1/1

Outdoor Directional Panel Antenna


ODV-032R20E-G

XPol, 790-960MHz, 32, 19.3dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
0-30o Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

790- 896

870- 960
45

dBi
deg
deg
deg
dB

18.8
34
10

19.3
32
9.5

0-10
>17(0o), >16(5o), >16(10o)
> 16
> 27(total power)
> 18
1.5:1
> 28
< -150
500
50
Direct Ground

dB
dB
dB
dBc
W

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1975x500x140 (77.8x19.7x5.5)
36 (79.4)
43 (94.8)
Fiberglass, Light Grey
00-ZJ11(12)
2x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
2322x635x305 (91.4x25.0x12.0)
50 (110)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

790MHz @ 0o

875MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

20

960MHz @ 0o

Issued: Nov12
Control: 0-0-1
1/1

Outdoor Directional Panel Antenna


ODV-065R15E-G

XPol, 790-960MHz, 65, 15.2dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
0-30Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
Cross-polar Discrimination @ 60
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

790-896

880-960
45

dBi
deg
deg
deg
dB
dB
dB
dB
dB

14.7
67
15

15.2
63
13

0-20
>18(0o), >16(10o), >16(20o)
>16
> 25(total power)
> 18
> 10
1.5:1
> 30
< -150
500
50
Direct Ground

dB
dBc
W

Mechanical
Dimensions, HxWxD
Weight,without Mounting Kit
Weight,with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1415x265x120 (55.7x10.4x4.7)
13.7 (30.2)
18.7 (41.2)
Fiberglass, Light Grey
SJA-B-12R(16)
2x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
1725x375x255 (67.9x14.8x10.0)
23.7 (52.2)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

790MHz @ 0o

870MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

21

960MHz @ 0o

Issued: Oct12
Control: 0-0-0
1/1

Outdoor Directional Panel Antenna


ODV-065R17E-G

XPol, 790-960MHz, 65, 16.6dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
0-30Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
Cross-polar Discrimination @ 60o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

790-896

880-960
45

dBi
deg
deg
deg
dB
dB
dB
dB
dB

16.2
67
9.7

16.6
65
9.2
0-10
18
16
> 25(total power)
20
10
< 1.5:1
> 30
< -150
500
1
50

dB
dBc
W

Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1975x265x125 (78.7x10.4x4.9)
19.5 (43.0)
24.5 (54.0)
Fiberglass, Light Grey
SJA-B-12R
2x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
2285x375x255 (89.9x14.8x10.0)
29.5 (65.0)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

806MHz @ 0o

880MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

22

960MHz @ 0o

Issued: Nov12
Control: 0-0-4
1/1

Outdoor Directional Panel Antenna


ODV-065R18E-G

XPol, 790-960MHz, 65, 17.5dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
Cross-polar Discrimination @ 60o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

790-896

880-960
45

dBi
deg
deg
deg
dB
dB
dB
dB
dB
dBc
W

17.0
67
7.7

17.5
65
7.3

0-12
18(0), 18(4), 16(8), 16(12)
> 25(total power)
20
10
< 1.5:1
> 30
< -150
500
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

2615x265x145 (103.0x10.4x5.7)
23 (50.7)
28.5 (62.8)
Fiberglass, Light Grey
00-ZJ10(08)
2x7/16 DIN-Female, bottom
-40 to +60
95
150 (93.2)
2915x375x275 (114.8x14.8x10.8)
35 (77.2)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

806MHz @ 0o

870MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

23

960MHz @ 0o

Issued: Nov12
Control: 0-0-0
1/1

Outdoor Directional Panel Antenna


ODV-065R15B

XPol, 806-960MHz, 65, 15.5dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

806-896

870-960
45

dBi
deg
deg
deg
dB
dB
dB

15.0

15.5
65
14
0-14
19(0o),17(7o),15(14o)
> 25
> 20
1.5:1
> 30
< -150
500
50
Direct Ground

dB
dBc
W

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed

mm (in)
kg (lb)
kg (lb)

C
%
km/h (mph)

1415x265x141 (55.7x10.4x5.6)
16 (35.3)
21 (46.3)
UV Resistant PVC, Light Grey
SJA-B-12R(16)
2x7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)

Shipping Dimensions, HxWxD


Shipping Weight

mm (in)
kg (lb)

1680x335x230 (66.1x13.2x9.1)
23 (50.7)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

840MHz @ 0o

870MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

24

930MHz @ 0o

Issued: Nov12
Control: 3-0-3
1/1

Outdoor Directional Panel Antenna


ODV-065R17B

XPol, 806-960MHz, 65, 17.0dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

806-896

870-960
45

dBi
deg
deg
deg
dB
dB
dB

16.5

17.0
65
10
0-10
18(0o),16(4o),10(10o)
> 25
> 17
1.5:1
> 30
< -150
500
100
50
Direct Ground

dB
dBc
W

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1975x265x141 (77.6x10.4x5.6)
16.5 (36.4)
22.5 (60.0)
UV Resistant PVC, Light Grey
00-ZJ10(12)
2x7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
2265x375x265 (89.2x14.8x10.4)
27 (59.5)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

806MHz @ 0o

870MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

25

960MHz @ 0o

Issued: Nov12
Control: 3-0-4
1/1

Outdoor Directional Panel Antenna


ODV-065R18B

XPol, 806-960MHz, 65, 17.6dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

806-896

870-960
45

dBi
deg
deg
deg
dB
dB
dB

17.1

17.6
65
7
0-8
18(0o),15(4o),13(8o)
> 25
> 20
1.5:1
> 30
< -150
500
50
Direct Ground

dB
dBc
W

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

2615x265x141 (103.0x10.4x5.6)
20.0 (44.1)
25.5 (56.2)
UV Resistant PVC, Light Grey
00-ZJ10(08)
2x7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
2915x375x280 (114.6x14.7x11.0)
32.0 (70.5)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

806MHz @ 0o

870MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

26

960MHz @ 0o

Issued: Nov12
Control: 3-0-3
1/1

Outdoor Directional Panel Antenna


ODV-090R17E-G

XPol, 790-960MHz, 90, 16.5dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

790-896

880-960
45

dBi
deg
deg
deg
dB
dB
dB

16.0

16.5
90
7
0-12
18(0o), 16(6o), 16(12o)
> 25(total power)
> 17
1.5:1
> 30
< -150
500
50
Direct Ground

dB
dBc
W

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

2615x265x145 (102.9x10.4x5.7)
25 (55.0)
30.5 (67.2)
Fiberglass, Light Grey
00-ZJ10(08)
2x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
2915x375x280 (114.8x14.8x11.0)
35 (77.0)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

820MHz @ 0o

930MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

27

960MHz @ 0o

Issued: Nov12
Control: 0-0-1
1/1

Outdoor Directional Panel Antenna


ODP-065R15Kxx-G

XPol, 1710-2170MHz, 65, 15.3dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Fixed(Optional)
Upper Sidelobe Suppression @ 0o~30 o
Front-To-Back Ratio
VSWR
Isolation Between Ports
Cross-polar Discrimination @ 0o
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

1710-1880

dBi
deg
deg
deg
dB
dB

15.0

dB
dB
dBc
W

1850-1990
45
15.2
65
12
0, 6
> 16
> 25
30
>1.5:1
> 30
30
> 17

1920-2170
15.3

< -150
300
100
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

665x120x60 (26.2x4.7x2.4)
3.0 (6.6)
4.7 (10.4)
Fiberglass, Light Grey
SJA-B-14F
2x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
885x260x170 (34.8x10.2x6.7)
5.6 (12.3)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz @ 0o

1920MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

28

2170MHz @ 0o

Issued: Nov12
Control: 0-0-0
1/1

Outdoor Directional Panel Antenna


ODP-065R18Kxx-G

XPol, 1710-2170MHz, 65, 18.0dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Fixed(Optional)
First Upper Sidelobe Suppression
Front-To-Back Ratio
VSWR
Isolation Between Ports
Cross-polar Discrimination @ 0o
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

1710-1880

dBi
deg
deg
deg
dB
dB

17.6

dB
dB
dBc
W

1850-1990
45
17.7
65
6.5
0, 6
18
> 25(total power)
1.4:1
> 30
> 17
< -150
300
100
50
Direct Ground

1920-2170
18.0

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1310x120x60 (51.6x4.7x2.4)
5.5 (12.1)
7.2 (15.9)
Fiberglass, Light grey
SJA-B-14F(12)
2x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
1510x190x150 (59.4x7.5x5.9)
9.2 (20.3)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz @ 0o

1920MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

29

2170MHz @ 0o

Issued: Nov12
Control: 0-0-0
1/1

Outdoor Directional Panel Antenna


ODV-032R21K-G

XPol, 1710-2170MHz, 32, 20.8dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz
dBi
deg
deg
deg
dB
dB
dB
dB
dBc
W

1710-1880

1850-1990
1920-2170
45
20.2
20.6
20.8
34
32
30
6.8
6.5
6
0-10
>20(00), >17(50), >16(100)
> 25(total power)
> 18
1.5:1
> 30
< -150
300
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1315x300x86 (51.8x11.8x3.4)
14.5 (32.0)
19.5 (43.0)
Fiberglass, Light Grey
SJA-B-12R(16)
2x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
1595x415x215 (62.8x16.3x8.5)
24.0 (52.9)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz @ 0o

1990MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

30

2170MHz @ 0o

Issued: Nov12
Control: 0-0-0
1/1

Outdoor Directional Panel Antenna


ODV-065R15K-G

XPol, 1710-2170MHz, 65, 15.3dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz
dBi
deg
deg
deg
dB
dB
dB
dB
dBc
W

1710-1880

1850-1990
1920-2170
45
14.7
15.0
15.3
65
13
12.5
12
0-20
>17(00), >16(100), >16(200)
o
>25(0-15 total power); >23(15-20o total power)
> 17
1.5:1
> 28
< -150
300
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting kit
Weight, with Mounting kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

650x145x86 (25.6x5.7x3.4)
5.6 (12.3)
7.3 (16.1)
Fiberglass, Light Grey
SJA-B-14C(16)
2x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
855x260x190 (33.7x10.2x7.5)
9.1 (20.1)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz @ 0o

1920MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

31

2170MHz @ 0o

Issued: Nov12
Control: 0-0-0
1/1

Outdoor Directional Panel Antenna


ODV-065R18K-G

XPol, 1710-2170MHz, 65, 18.0dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
Cross-polar Discrimination @ 60 o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz
dBi
deg
deg
deg
dB
dB
dB
dB
dB
dBc
W

1710-1880

1850-1990
1920-2170
45
17.5
17.7
18.0
67
65
63
7.2
6.8
6.4
0-10
>20(0o), >17(5o), >16(10o)
25(total power)
> 18
> 10(typ.)
1.5:1
> 30
< -150
300
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1315x145x86 (51.8x5.7x3.4)
8.5 (18.7)
10.3 (22.7)
Fiberglass, Light Grey
SJA-B-14D(10)
2x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
1505x245x190 (59.2x9.6x7.5)
13 (28.7)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz @ 0o

1990MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

32

2170MHz @ 0o

Issued: Nov12
Control: 0-0-0
1/1

Outdoor Directional Panel Antenna


ODV-065R18K

XPol, 1710-2170MHz, 65, 18.0dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
Cross-polar Discrimination @ 60
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz
dBi
deg
deg
deg
dB
dB
dB
dB
dB
dBc
W

1710-1880

1850-1990
1920-2170
45
17.5
17.7
18.0
67
65
63
7.2
6.8
6.4
0-10
>20(0o), >17(5o), >16(10o)
25(total power)
> 18
> 10(typ.)
1.5:1
> 30
< -150
300
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1315x145x86 (51.8x5.7x3.4)
7.5 (16.5)
9.3 (20.5)
UV Resistant PVC, Light Grey
SJA-B-14D(10)
2x7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
1505x245x190 (59.2x9.6x7.5)
12 (26.4)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz @ 0o

1990MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

33

2170MHz @ 0o

Issued: Nov12
Control: 0-0-0
1/1

Outdoor Directional Ultra-Wide Band Antenna


ODV-065R18J-G

XPol, 1710-2690MHz, 65o, 18.0dBi

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

0-30 Upper Sidelobe Suppression


Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power Per Port
Impedance
Lightning Protection

dB
dB
dB
dB
dBc
W

17101880

18501990

1920230024902170
2500
2690
45
17.4
17.6
17.8
18.0
17.8
68
66
65
63
64
7.4
7.0
6.6
5.6
5.2
012
18(0 o), 18(6 o),
18(0 o),17(6 o),
o
17(12 )
16(12 o)
15
14
> 25
18 (typ.)
< 1.5:1
> 28
< -150
250
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1375x160x83 (54.1x6.3x3.3)
10.5 (23.1)
12 (26.4)
Fiberglass, Light Grey
SJA-B-14D
2 x 7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
1563x245x180 (61.5x9.6x7.1)
14.5 (31.9)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz @ 2

1920MHz @ 2

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

34

2500MHz @ 2

Issued: Nov12
Control: 0-0-3
1/1

Outdoor Directional Ultra-Wide Band Antenna


ODV-065R18J

XPol, 1710-2690MHz, 65o, 18.0dBi

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

0-30 Upper Sidelobe Suppression


Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power Per Port
Impedance
Lightning Protection

dB
dB
dB
dB
dBc
W

17101880

18501990

1920230024902170
2500
2690
45
17.4
17.6
17.8
18.0
17.8
68
66
65
63
64
7.4
7.0
6.6
5.6
5.2
012
18(0 o), 18(6 o),
18(0 o),17(6 o),
o
17(12 )
16(12 o)
15
14
> 25
18(typ.)
< 1.5:1
> 28
< -150
250
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1375x160x83 (54.1x6.3x3.3)
9 (19.8)
10.5 (23.1)
UV Resistant PVC, Light Grey
SJA-B-14D
2x7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
1563x245x180 (61.5x9.6x7.1)
13 (28.7)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz @ 2

1920MHz @ 2

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

35

2500MHz @ 2

Issued: Nov12
Control: 0-0-3
1/1

Outdoor Directional Panel Antenna


ODV-090R17K-G

XPol, 1710-2170MHz, 90, 16.5dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power Per Port
Impedance
Lightning Protection

MHz
dBi
deg
deg
deg
dB
dB
dB
dB
dBc
W

1710-1880

1850-1990
1920-2170
45
16.3
16.4
16.5
90
7
0-10
>18(00), >16(50), >16(100)
> 25(total power)
> 17
1.5:1
> 28
< -150
300
100
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting kit
Weight, with Mounting kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1310x173x81 (51.5x6.8x3.2)
9.0 (19.8)
10.8 (23.8)
Fiberglass, Light Grey,
SJA-B-14C(10)
2x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
1435x230x210 (56.5x9.1x8.3)
12.8 (28.2)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz @ 0o

1920MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

36

2170MHz @ 0o

Issued: Nov12
Control: 0-0-1
1/1

Outdoor Directional Dual-band Antenna


ODP-065R17B18Kxxyy

XXPol,806-960/1710-2170MHz,65,16.7/17.5dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Fixed (Optional)
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports / Bands
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

MHz

806-896

dBi
deg
deg
deg
dB
dB
dB

16.3

870-960
45
16.7
65
10.0
0/0, 6/6
> 18(0o), > 16(6o)
> 25
> 17
1.5:1
> 28 / > 40
< -150
500
50
Direct Ground

dB
dBc
W

1710-2170
17.5
5.5

250

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1975x265x145 (77.8x10.4x5.7)
18 (39.7)
24 (52.9)
UV Resistant PVC, Light Grey
00-ZJ10(14)
4x7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
2285x375x275 (90.0x14.8x10.8)
30 (66.1)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

870MHz @ 0o

1710MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

37

1880MHz @ 0o

Issued: Nov12
Control: 3-0-3
1/1

Outdoor Directional Dual-band Antenna


ODV-065R14E17K-G

XXPol, 790-960/1710-2170MHz, 65, 14.0/16.8dBi

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports / Bands
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB

790896

880960

13.5
68
18.6

14.0
65
17

17101880
45
16.6
65
8.2

0-20
17(0o),16(7o)
15(14o),
13(20o)

18501990

19202170

16.8
64
7.6
0-10

16.8
63
7.2

18(0o),
16(5o),14(10o)
25
> 17
< 1.5:1
28 / 33
< -150

dB
dBc
W

500

300
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1200x265x145 (47.2x10.4x5.7)
16 (35.3)
22 (48.5)
Fiberglass, Light Grey
SJA-B-12R(16)
4x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
1505x375x280 (59.3x14.8x11.0)
26 (57.3)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

900MHz @ 0o

1710MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

38

1920MHz @ 0o

Issued: Nov12
Control: 0-0-0
1/1

Outdoor Directional Dual-band Antenna


ODV-065R15E18K-G

XXPol, 790-960/1710-2170MHz, 65, 15.0/17.7dBi

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

0-30Upper Sidelobe Suppression

dB

Front-To-Back Ratio
Cross-polar Discrimination @ 0o
Cross-polar Discrimination @ 60o
VSWR
Isolation Between Ports / Bands
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB
dB
dB
dBc
W

790896

880960

14.5
68
14

15.0
65
13

0-20
18(0o),17(7o),
16 (14o),14(20o)

17101880
45
17.4
65
6.6

18501990

19202170

17.6
64
6.2
0-10

17.7
63
5.8

18(0o),17(5o),16(10o)

17(0o),16(7o),
17(0o),15(5o),12(10o)
15(14o),12(20o)
> 25(total power)
18
10(typ.)
< 1.5:1
> 28 / > 33
< -150
500
300
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1515x265x145 (59.6x10.4x5.7)
19.2 (42.3)
25.7 (56.7)
Fiberglass, Light Grey
00-ZJ10(12)
4x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
1825x375x275 (71.9x14.8x10.8)
29 (63.9)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

900MHz @ 0o

1920MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

39

2170MHz @ 0o

Issued:Nov12
Control: 0-0-0
1/1

Outdoor Directional Dual-band Antenna


ODV-065R17E18K-G

XXPol, 790-960/1710-2170MHz, 65, 16.7/17.7dBi

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

0-30Upper Sidelobe Suppression

dB

Front-To-Back Ratio
Cross-polar Discrimination @ 0o
Cross-polar Discrimination @ 60o
VSWR
Isolation Between Ports / Bands
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB
dB
dB
dBc
W

790896

880960

16.2
68
10

16.7
65
9.3

17101880
45
17.4
65
6.6

18501990

19202170

17.6
17.7
64
63
6.2
5.8
0-10
0-10
18(0o),
18(0o),
16(5o),16(10o)
17(5o),16(10o)
16(0o),
15(0o),
o
o
14(5 ),14(10 )
14(5o),10(10o)
> 25(total power)
18
10
< 1.5:1
> 28 / > 33
< -150
500
300
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1975x265x145 (77.8x10.4x5.7)
23.5 (51.8) ,
30 (66.1),
Fiberglass, Light Grey
00-ZJ10(14)
4x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
2280x375x275 (89.8x14.8x10.8)
35.5 (78.3) ,

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

820MHz @ 00

1850MHz @ 00

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

40

2170MHz @ 00

Issued: Nov12
Control: 0-0-0
1/1

Outdoor Directional Dual-band Antenna


ODV-065R17E18K

XXPol, 790-960/1710-2170MHz, 65, 16.7/17.7dBi

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

0-30Upper Sidelobe Suppression

dB

Front-To-Back Ratio
Cross-polar Discrimination @ 0o
Cross-polar Discrimination @ 60o
VSWR
Isolation Between Ports / Bands
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB
dB
dB
dBc
W

790896

880960

16.2
68
10

16.7
65
9.3

17101880
45
17.4
65
6.6

18501990

19202170

17.6
17.7
64
63
6.2
5.8
0-10
0-10
18(0o),
18(0o),
16(5o),16(10o)
17(5o),16(10o)
16(0o),
15(0o),
o
o
14(5 ),14(10 )
14(5o),10(10o)
> 25(total power)
18
10
< 1.5:1
> 28 / > 33
< -150
500
300
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1975x265x145 (77.8x10.4x5.7)
22.0 (48.5) ,
28.5 (62.8),
UV Resistant PVC, Light Grey
00-ZJ10(14)
4x7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
2280x375x275 (89.8x14.8x10.8)
34.0 (75.0) ,

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

820MHz @ 00

1850MHz @ 00

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

41

2170MHz @ 00

Issued: Nov12
Control: 0-0-1
1/1

Outdoor Directional Dual-band Antenna


ODV-065R18EK-G

XXPol, 790-960/1710-2170MHz, 65, 17.3/17.7dBi

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

Front-To-Back Ratio
Cross-polar Discrimination @ 0o
Cross-polar Discrimination @ 60o
VSWR
Isolation Between Ports / Bands
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB
dB
dB
dBc
W

790896

880960

16.8
68
8.0

17.3
65
7.5
0-10

17101880
45
17.4
65
6.6

18501990

19202170

17.6
64
6.2
0-10

17.7
63
5.8

17(0o),17(5o),
18(0o),17(5o),16(10o)
15(10o)
> 25(total power)
18
10
< 1.5:1
> 28 / > 33
< -150
500
300
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

2515x265x145 (99.0x10.4x5.7)
26 (57.3)
32.5 (71.7)
Fiberglass, Light Grey
00-ZJ10(08)
4x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
2830x375x275 (111.4x14.8x10.8)
39 (86.0)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

900MHz @ 0o

1795MHz @ 2o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

42

1990MHz @ 2o

Issued: Nov12
Control: 0-0-0
1/1

Outdoor Directional Dual-band Antenna


ODV-065R18EK

XXPol, 790-960/1710-2170MHz, 65, 17.3/17.7dBi

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

Front-To-Back Ratio
Cross-polar Discrimination @ 0o
Cross-polar Discrimination @ 60o
VSWR
Isolation Between Ports / Bands
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB
dB
dB
dBc
W

790896

880960

16.8
68
8.0

17.3
65
7.5
0-10

17101880
45
17.4
65
6.6

18501990

19202170

17.6
64
6.2
0-10

17.7
63
5.8

17(0o),17(5o),
18(0o),17(5o),16(10o)
15(10o)
> 25(total power)
18
10
< 1.5:1
> 28 / > 33
< -150
500
300
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

2515x265x145 (99.0x10.4x5.7)
24 (52.9)
30.5 (67.2)
UV Resistant PVC , Light Grey
00-ZJ10(08)
4x7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
2830x375x275 (111.4x14.8x10.8)
37 (81.6)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

900MHz @ 0o

1795MHz @ 2o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

43

1990MHz @ 2o

Issued: Nov12
Control: 0-0-3
1/1

Outdoor Directional Dual-band Antenna


ODV-065R15E18J-G

XXPol, 790-960/1710-2690MHz, 65, 14.8/18.0dBi

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

Front-To-Back Ratio
VSWR
Isolation Between Ports
Cross-polar Discrimination @ 0o
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB
dB
dBc
W

790896

880960

14.5
67
15

14.8
63
13.5

17101850
45
16.8
67
6.5

19202170

24902690

17.3
18.0
65
60
5.8
4.5
0-14
0-10
>17(0o), >16(7o),
>17(0o),
> 15(14o)
>15(5o), >14(10o)
> 25
1.5:1
> 28 / >30
> 18 (typ.)
< -150
500
250
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1570x320x145 (61.8x12.6x5.7)
23 (50.7)
28.5 (62.8)
Fiberglass, Light Grey
00-ZJ10
4x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
1920x430x280 (75.6x16.9x11.0)
35 (77.2)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

790MHz @ 0o

1850MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

44

2690MHz @ 0o

Issued: Nov12
Control: 0-0-2
1/1

Outdoor Directional Dual-band Antenna


ODV-065R17E18J-G

XXPol, 790-960/1710-2690MHz, 65, 16.3/18.0dBi

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

0-30Upper Sidelobe Suppression


Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB

dB
dBc
W

790896

880960

15.8
66
10

16.3
63
9.5

17101990
45
16.8
67
6.5

19202170

24902690

17.3
18.0
65
60
5.8
4.5
0-10
0-10
18(0 o),
>17(0o),
17(5o),16(10 o)
>15(5o), >14(10o)
15
14
> 25
> 18 (typ.)
1.5:1
> 28 / > 30
< -150
500
250
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1995x320x145 (78.5x12.6x5.7)
28 (61.6)
33.5 (73.7)
Fiberglass, Light Grey
00-ZJ11
4x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
2350x430x270 (92.5x16.9x10.6)
40 (88.0)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

790MHz @ 0o

1850MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

45

2690MHz @ 0o

Issued: Nov12
Control: 0-0-2
1/1

Outdoor Directional Dual-band Antenna


ODV-065R18EJ-G

XXPol, 790-960/1710-2690MHz, 65, 17.3/18.0dBi

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

0-30Upper Sidelobe Suppression


Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports / Bands
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB
dB
dB
dBc
W

790896

880960

16.6
67
7.2

17.3
63
6.7

17101990
45
16.8
67
6.5

19202170

24902690

17.3
18.0
65
60
5.8
4.5
0-10
0-10
18(0 o),17(5 o),
18(0 o), 17(5 o),
16(10 o)
16(10 o)
15
14
> 25
18(typ.)
< 1.5:1
> 28 / > 30
< -150
500
250
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

C
%
km/h (mph)
mm (in)
kg (lb)

2750x320x145
32 (70.5)
42.5 (93.7)
Fiberglass, Light Grey
00-ZJ11(08)
4x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
3105x430x270 (122.2x16.9x10.6)
49 (108)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

790MHz @ 0o

1850MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

46

2500MHz @ 0o

Issued: Nov12
Control: 0-0-3
1/1

Outdoor Directional Twin Antenna


XXPol, 1710-2170/1710-2170MHz, 65/65,
18.0/18.0dBi

ODV2-065R18K-G

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
Cross-polar Discrimination @ 60o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power Per Port
Impedance
Lightning Protection

MHz
dBi
deg
deg
deg
dB
dB
dB
dB
dB
dBc
W

1710-1880

1850-1990
1920-2170
45
17.5
17.7
18.0
67
65
63
7.2
6.8
6.4
0-10 / 0-10
>20(0o), >17(5o), >16(10o)
25(total power)
> 18
> 10(typ.)
1.5:1
> 30
< -150
300
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without mounting Kit
Weight, with mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1315x265x90 (51.8x10.4x3.5)
15.5 (34.2)
20.5 (45.2)
Fiberglass, Light Grey
SJA-B-12R(16)
4x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
1595x375x215 (62.8x14.8x8.5)
25.0 (55.1)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz @ 0o

1990MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

47

2170MHz @ 0o

Issued: Nov12
Control: 0-0-2
1/1

Outdoor Directional Twin Antenna


XXPol, 1710-2170/1710-2170MHz, 65/65,
18.0/18.0dBi

ODV2-065R18K

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range
First Upper Sidelobe Suppression
Front-To-Back Ratio
Cross-polar Discrimination @ 0o
Cross-polar Discrimination @ 60o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power Per Port
Impedance
Lightning Protection

MHz
dBi
deg
deg
deg
dB
dB
dB
dB
dB
dBc
W

1710-1880

1850-1990
1920-2170
45
17.5
17.7
18.0
67
65
63
7.2
6.8
6.4
0-10 / 0-10
>20(0o), >17(5o), >16(10o)
25(total power)
> 18
> 10(typ.)
1.5:1
> 30
< -150
300
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1315x300x86 (51.8x11.8x3.4)
14.5 (32.0)
19.5 (43.0)
UV Resistant PVC, Light Grey
SJA-B-12R(16)
4x7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
1595x415x215 (62.8x16.3x8.5)
24 (52.9)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz @ 0o

1990MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

48

2170MHz @ 0o

Issued: Nov12
Control: 0-0-2
1/1

Outdoor Directional Twin Antenna


XXPol, 1710-2690/1710-2690MHz, 65o/65o,
17.7/17.7dBi

ODV2-065R18J-G

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

0-30 Upper Sidelobe Suppression


Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power Per Port
Impedance
Lightning Protection

dB
dB
dB
dB
dBc
W

17101880

18501990

1920230024902170
2500
2690
45
16.8
17.2
17.4
17.7
17.6
68
66
65
63
64
7.4
7.0
6.6
5.6
5.2
012 / 0-12
18(0 o),16(6 o),
17(0 o),16(6 o),
15(12 o)
15(12 o)
15
14
> 25
18 (typ.)
< 1.5:1
> 28
< -150
250
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1330x300x86 (52.4x11.8x3.4)
19.5 (42.9)
24.5 (53.9)
Fiberglass, Light Grey
SJA-B-12R(16)
4x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
1615x415x215 (63.6x16.3x8.5)
31.5 (69.3)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz @ 2

1920MHz @ 2

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

49

2500MHz @ 2

Issued: Nov12
Control: 0-0-7
1/1

Outdoor Directional Twin Antenna


XXPol, 1710-2690/1710-2690MHz, 65o/65o,
17.7/17.7dBi

ODV2-065R18J

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

0-30 Upper Sidelobe Suppression


Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power Per Port
Impedance
Lightning Protection

dB
dB
dB
dB
dBc
W

17101880

18501990

1920230024902170
2500
2690
45
16.8
17.2
17.4
17.7
17.6
68
66
65
63
64
7.4
7.0
6.6
5.6
5.2
012 / 0-12
18(0 o),16(6 o),
17(0 o),16(6 o),
15(12 o)
15(12 o)
15
14
> 25
18(typ.)
< 1.5:1
> 28
< -150
250
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1330x300x86 (52.4x11.8x3.4)
18 (39.7)
23 (50.7)
UV Resistant PVC, Light Grey
SJA-B-12R(16)
4x7/16 DIN-Female, Bottom
-40o +60
95
150 (93.2)
1615x415x215 (63.6x16.3x8.5)
30 (66.1)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz @ 2

1990MHz @ 2

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

50

2500MHz @ 2

Issued: Nov12
Control: 0-0-7
1/1

Outdoor Directional Tri-band Antenna


ODV-065R15B15J15J

XXXPol, 806-960/1710-2690/1710-2690MHz, 65,


15.0/15.5/15.5dBi

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

deg
dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

Front-To-Back Ratio
Cross-polar Discrimination @ 0
VSWR
Isolation Between Ports
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB
dB
dBc
W

806896

870960

15.0
65
14
13.5
0-14

17101880

18501990
45

19202170

23002500

15.0
67
14

15.2
65
13.7

15.5
63
13.5
0-12/0-12

61
12

17(0),
16(7),
15(14)

24902690

15.0
60
11

16(0), 15(6), 14(12)


> 25
> 17
1.5:1

> 28

> 25
< -150

500

250
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1415x335x145 (55.7x13.2x5.6)
19.5 (43.0)
25 (55.1)
UV Resistant PVC, Light Grey
00-ZJ10(16)
6x7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
1740x450x270 (68.5x17.7x10.6)
29 (63.9)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

896MHz @ 2o

1990MHz @ 2o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

51

2300MHz @ 2o

Issued: Nov12
Control: 1-0-0
1/1

Outdoor Directional Tri-band Antenna


XXXPol, 790-960/1710-2170/1710-2170MHz,
65, 17.5/17.5/17.7dBi

ODV-065R18EKK-G
Technical Specifications
Electrical
Frequency Range

MHz

Polarization

deg

790896

880960
45

Top
Gain
Bottom
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

dBi

16.8

17.5

deg
deg
deg

68
8

65
7.5

First Upper Sidelobe Suppression

dB

Front-To-Back Ratio
Cross-polar Discrimination @ 0o
Cross-polar Discrimination @ 60o
VSWR
Isolation Between Ports / Bands
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB
dB
dB
dBc
W

17101880
17.2
17.4
65
6.8

185019201990
2170
Quad 45
17.4
17.5
17.6
17.7
64
63
6.2
5.8
0-10 / 0-10

0-10
18(0o), 16(5o),
18(0o), 17(5o), 16(10o)
16(10o)
> 25(total power)
18
10
1.5:1
> 28 / > 33
< -150
500
300
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

2730x265x145 (107.5x10.4x5.7)
34.0 (75.0)
42.5 (93.7)
Fiberglass, Light Grey
00-ZJ11(00)
6x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
3045x375x275 (120.0x14.8x10.8)
48.5 (106.9)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

900MHz @ 0o

1795MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

52

1990MHz @ 0o

Issued: Nov12
Control: 0-0-2
1/1

Outdoor Directional Tri-band Antenna


ODV-065R15E18J18J-G

XXXPol, 790-960/1710-2690/1710-2690MHz, 65,


15.0/17.7/17.7dBi

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

deg
dBi
deg
deg
deg

First Upper Sidelobe Suppression

dB

0-30Upper Sidelobe Suppression


Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports / Bands
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB
dB

790896

880960

14.5

15.0
65
14
0-14
>17(0),
>16(7),
>15(14)
15

dB
dBc
W

500

17101990
45
17.2
67
7.3

19202170

24902690

17.5
17.7
65
61
6.5
5.3
0-12 / 0-12
>16(0o),
>18(0o),
>16(6o),
>15(6o),
>15(12o)
>14(12o)
14
> 25
18(typ.)
1.5:1
> 28 / > 30
< -150
250
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1415x500x140 (55.7x19.7x5.5)
32 (70.5)
37 (81.6)
Fiberglass, Light Grey
00-ZJ11
6x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
1705x635x305 (67.1x25x12)
43 (90.2)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

790MHz @ 0

1850MHz @ 4

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

53

2500MHz @ 4
Issued: Nov2
Control: 0-0-6
1/1

Outdoor Directional Tri-band Antenna


XXXPol, 790-960/1710-2690/1710-2690MHz, 65,
16.3/16.3/16.8dBi

ODV-065R17EJJ-G

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain

Top
Bottom

dBi

Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

deg
deg
deg

First Upper Sidelobe Suppression

dB

0-30Upper Sidelobe Suppression


Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports / Bands
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB
dB
dB
dBc
W

790896

880960

17101990

192024902170
2690
45
Quad 45
16.3
15.7
16.0
15.8
16.3
16.2
16.5
16.8
67
64
66
64
61
10
9.5
8.5
8.0
6.3
0-10
0-12 / 0-12
18(0 o),
18(0 o), 17(6 o),
17(5o),16(10 o)
16(12 o)
15
14
> 25(typ.)
18(typ.)
< 1.5:1
> 28 / > 30
< -150
500
250
200
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1995x320x145 (78.5x12.6x5.7)
31.0 (68.3)
36.5 (80.5)
Fiberglass, Light Grey
00-ZJ11(08)
6x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
2350x430x270 (92.5x16.9x10.6)
42 (92.6)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

790MHz @ 2o

1850MHz @ 2o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

54

2690MHz @ 2o

Issued: Nov12
Control: 0-0-6
1/1

Outdoor Directional Tri-band Antenna


XXXPol, 790-960/1710-2690/1710-2690MHz, 65,
17.3/17.1/17.6dBi

ODV-065R18EJJ-G

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Top
Bottom

Gain

dBi

Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

deg
deg
deg

First Upper Sidelobe Suppression

dB

0-30 Upper Sidelobe Suppression


Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports / Bands
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB
dB
dB
dBc
W

790896

880960

17101990

192024902170
2690
45
Quad 45
16.2
16.7
17.1
16.6
17.3
16.7
17.2
17.6
67
63
67
65
61
7
6.5
7.2
6.6
5.2
0-10
0-12
18(0 o),17(5 o),
17(0 o),16(6 o),
16(10 o)
15(12 o)
15
14
> 25
18(typ.)
< 1.5:1
> 28 / > 30
< -150
500
250
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

2750x320x145 (108.3x12.6x5.7)
37 (81.6)
47.5 (104.5)
Fiberglass, Light Grey
00-ZJ11(08)
6x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
3105x430x270 (122.2x16.9x10.6)
53.5 (117.7)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

790MHz @ 0o

2170MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

55

2500MHz @ 0o

Issued: Nov12
Control: 0-0-4
1/1

Outdoor Directional Twin Antenna


ODV2-065R15E18K-G

XXPol, 790-960/1710-2170MHz, 65, 15.0/18.0dBi

Technical Specifications
Electrical
Frequency Range

MHz

790896

880960

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Electrical Downtilt Range

deg
dBi
deg
deg
deg

14.5
69
14

15.0
67
13

First Upper Sidelobe Suppression

dB

Front-To-Back Ratio
Cross-polar Discrimination @ 0o
VSWR
Isolation Between Ports/ Bands
3rd Order Intermodulation @ 2x43 dBm
Maximum Power per Port
Impedance
Lightning Protection

dB
dB
dB
dBc
W

17101880
45
17.4
66
6.6

18501990

19202170

17.6
17.7
65
60
6.2
5.8
0-20
0-10
18(0o),17(7o),
18(0o),
16(14o),15(20o)
16(5o), 15(10o)
> 25
> 17
1.5:1
> 28 / > 28
< -150
500
300
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1515x500x140 (59.6x19.7x5.5)
38 (83.8)
46 (101.4)
Fiberglass, Light Grey
00-ZJ11(12)
8x7/16 DIN-Female, Bottom
-50 to +70
95
150 (93.2)
1850x635x305 (72.8x25x12)
53 (117.0)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

900MHz @ 0o

1795MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

56

1990MHz @ 0o

Issued: Nov12
Control: 0-0-1
1/1

Outdoor Directional Antenna for Microcell


ODM-030V16K0-2

VPol, 1710-2170MHz, 30, 13.5 dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Front-To-Back Ratio
VSWR
Maximum Power
Impedance

MHz

1710-1880

dBi
deg
deg
dB
W

1850-1990
Vertical
13.5
30
30
> 24
1.6:1
100
50

1920-2170

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

280x280x50 (11.0x11.0x2.0)
1.5 (3.3)
1.7 (3.7)
ABS, White
Pipe mount included
TNC or N, Rear
-40 to +60
95
150 (93.2)
290x280x120 (11.4x11.0x4.7)
2.1 (4.6)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz

1990MHz

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

57

2170MHz

Issued: Nov12
Control: 3-0-4
1/1

O
Outdoor
D
Direction
nal Anten
nna for Microcell
M
O
ODM-030V
V18B0

VPol, 824
4-960MHz, 30,
3
18dBi

T
Technica
l Specific
cations
E
Electrical
l
Frequency Range
F
P
Polarization
G
Gain
H
Horizontal
Bea
amwidth
V
Vertical
Beamwidth
F
Front-To-Back
k Ratio
V
VSWR
M
Maximum
Pow
wer
I
Impedance
L
Lightning
Prottection

MHz

824--960
Verttical
18
8
30
0
14
4
> 33
3
1..4:1
20
00
50
0
Direct Ground
G

dBi
deg
deg
dB
W

M
Mechanic
cal
Dimensions, HxWxD
D
H
(with reflector)
r
W
Weight,
without Mounting Kit
K
W
Weight,
with Mounting
M
Kit
R
Radome
Material and Colorr
M
Mounting
Kit
C
Connector
Typ
pe and Locatio
on
O
Operational
Te
emperature
O
Operational
Humidity
O
Operational
W
Wind
Speed
S
Shipping
Dime
ensions
Antenna
a
S
Shipping
Weig
ght
Reflecto
or

mm (in)
kg (lb)
kg (lb)

1251
1x796x474 (4
49.3x31.3x18..7)
20 (44
4.1)
25 (55
5.1)
PVC, Ligh
ht Grey
SJA-B-12
2R(16)
N-Female,, Bottom
-30 to +55
95
150 (9
93.2)
1480
0x335x305 (5
58.3x13.2x12..0)
27 (59
9.5)
8 (17
7.6)

C
%
km/h (mph)
mm (in)
kg (lb)

A
Antenna
Pattern

Vertical
pattern

Horizontal
pattern

870MHz

824MHz

Information con
ntained in this document
d
is sub
bject to confirma
ation at time of ordering.
o
http://www.com
mba-telecom.com

58

960MHz

Issued: Nov12
2
Control: 3-2-2
1/1

Outdoor Directional Antenna for Microcell


ODM-075V11N0

VPol, 790-960/1710-2500MHz, 75, 9.7/11.0dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Front-To-Back Ratio
VSWR
Maximum Power
Impedance
Lightning Protection

MHz

790-960

dBi
deg
deg
dB

9.7
75
58

1710-2500
Vertical
11.0
68
48
> 22
1.5:1
100
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Antenna Weight
Shipping
Antenna

mm (in)
kg (lb)
kg (lb)

480x282x54 (18.9x11.1x2.1)
1.5 (3.3)
1.7 (3.7)
PVC, Light Grey
Wall or pole mount included
N-Female, Bottom
-40 to +60
95
150 (93.2)
575x408x158 (22.6x16.1x6.2)
2.0 (4.4)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

870MHz

1880MHz

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

59

2500MHz

Issued: Nov 12
Control: 3-1-4
1/1

Outdoor Directional Antenna for Microcell


ODP-030V20K0

VPol, 1710-2170MHz, 30, 20.0dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
First Upper Sidelobe Suppression
Front-To-Back Ratio
VSWR
3rd Order Intermodulation @ 2x43 dBm
Maximum Power
Impedance
Lighting Protection

MHz

1710-1880

dBi
deg
deg
dB
dB

19.5

1850-1990
Vertical

1920-2170
20.0

33
7.5
> 16
> 33(typ. 40)
1.4:1
< -150
100
50
Direct Ground

dBc
W

32
7.0

1.5:1

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

1210x320x110 (47.6x12.6x4.3)
8.5 (18.7)
13 (28.7)
PVC, Light Grey
SJA-B-12R(16)
7/16 DIN-Female, Bottom
-40 to +60
95
150 (93.2)
1495x395x200 (58.9x15.6x7.9)
16 (35.3)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz

1990MHz

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

60

2170MHz

Issued: Nov12
Control: 3-0-4
1/1

Outdoor Directional Panel Antenna


VPol, 806-960/1710-2170/2300-2690MHz, 32,
11.0/15.0dBi

ODP-032V15N

Technical Specifications
Electrical
Frequency Range

MHz

Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Front-To-Back Ratio
1st Upper Sidelobe Suppression
VSWR
Isolation Between Bands
3rd Order Intermodulation @ 2x43 dBm
Maximum Power
Impedance
Lighting Protection

dBi
deg
deg
dB
dB

790896

880960

171019201990
2170
Vertical
10.8
12.5
13.5
40
41
35
38
38
35
> 25
2>
36
> 18
32
>1.5:1
>1.4:1
25
< -150
200
50
Direct Ground

11.0
46
36

dB
dBc
W

23002500

24902690

14.0
27
26

15.0
25
25

100

Mechanical
Dimensions, HxWxD
Weight,
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Operational Wind Speed
Shipping Dimensions, HxWxD
Antenna Weight
Shipping
Antenna

mm (in)
kg (lb)

1095x500x140 (43.1x19.7x5.5)
22 (48.5)
Fiberglass, Light Grey
00-ZJ10
27/16 DIN-Female, Bottom
-50 to +70
95
110 (68.31)
1375 x635x290 (54.1x24.8x11.3)
32 (70.6)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

880MHz @ 0o

1850MHz @ 0o

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

61

2400MHz @ 0o

Issued: Dec12
Control: 1-0-0
1/1

Outdoor Yagi Antenna


OYI-040V12K0-2

VPol, 1710-2170MHz, 40, 12.5dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Front-To-Back Ratio
VSWR
Maximum Power
Impedance
Lighting Protection

MHz

1710-1880

dBi
deg
deg
dB

11
40
38

1850-1990
Vertical
12.0

1920-2170
12.5
36
32

> 15
1.5:1
100
50
Direct Ground

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Radome Material and Color
Mounting Kit
Connector Type and Location
Operational Temperature
Operational Humidity
Survival Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm(in)
kg

595x150x90 (23.4x5.9x3.5)
0.9 (2.0)
UV Resistant PVC, Light Grey
Pole Mount included
N-Female, Bottom
-40 to +60
95
200 (124.3)
606x161x107 (23.9x6.3x4.2)
1.4 (3.1)

C
%
km/h
mm(in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1710MHz

1920MHz

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

62

2170MHz

Issued: Nov12
Control: 0-0-2
1/1

Outdoor Yagi Antenna


OYI-040V13B0-2

VPol, 806-960MHz, 40, 13dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
Front-To-Back Ratio
VSWR
Maximum Power
Impedance
Lighting Protection

MHz

806-960
Vertical
13
30
30
> 18
1.5:1
100
50
Direct Ground

dBi
deg
deg
dB
W

Mechanical
Dimensions, HxWxD
Weight, without Mounting Kit
Weight, with Mounting Kit
Mounting Kit
Connector Type
Operational Temperature
Operational Humidity
Survival Wind Speed
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)
kg (lb)

990x195x105 (39.0x7.8x4.1)
1.25 (2.8)
1.35 (3.0)
Pole Mount included
N-Female
-40 to +60
95
200 (124.3)
1000x200x110 (39.4x15.7x4.3)
1.45 (3.2)

C
%
km/h (mph)
mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

830MHz

900MHz

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

63

960MHz

Issued: Nov12
Control: 0-0-2
1/1

Indoor Directional Wall Mounted Antenna


IWH-065V07N0

VPol, 670-960/1710-2700, 65, 7dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
VSWR
Power Handling
Impedance

MHz

670-800

800-960

1710-2500
Vertical

4.5
75
70

dBi
deg
deg
2.0:1

2500-2700
7.0
60
50

1.5:1
50
50

1.8:1

Mechanical
Dimensions, HxWxD
Weight
Radome Material and Color
Mount
Reflector Material
Radiating Element Material
Connector Type
Environmental Class
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)

210x180x43 (8.3x7.1x1.7)
0.5 (1.1)
PVC, White
Wall
Aluminum
Printed Circuit Board
N-Female
Indoor
250x190x60 (9.8x7.5x2.4)
0.8 (1.8)

mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

870MHz

1880MHz

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

64

2500MHz

Issued: Jul10
Control: 0-0-1
1/1

Indoor Directional Wall Mounted Antenna


IWH-090V08N0-5

VPol, 806-960/1710-2700, 90, 8dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
VSWR
3rd Order Intermodulation @ 2x33 dBm
Power Handling
Impedance

MHz

806-960

dBi
deg
deg

7
90

dBc
W

1710-2500
Vertical
8
75
65
1.5:1
-140
100
50

2500-2700
7
65

Mechanical
Dimensions, HxWxD
Weight
Radome Material and Color
Mount
Reflector Material
Radiating Element Material
Connector Type
Environmental Class
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg (lb)

273x173x52 (10.7x6.8x2.0)
0.6 (1.3)
ABS, Light Grey, RAL7035
Wall
Aluminum
Aluminum
N-Female
Indoor
338x221x80 (13.3x8.7x3.1)
0.8 (1.8)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

806MHz

1710MHz

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

65

2500MHz

Issued: Oct12
Control: 3-0-2
1/1

Indoor Directional Ceiling Mounted Antenna


IXD-120V06N0-03

VPol, 806-960/1710-2500, 120, 6dBi

Technical Specifications
Electrical
Frequency Range
Polarization
Gain
Horizontal Beamwidth
Vertical Beamwidth
VSWR
Power Handling
Impedance

MHz

806-960

1710-2500
Vertical
6
120
100-120
1.5:1
100
50

dBi
deg
deg
W

Mechanical
Dimensions, HxDia
Weight
Radome Material and Color
Mount
Reflector Material
Radiating Element Material
Connector Type
Environmental Class
Shipping Dimensions, HxWxD
Shipping Weight

mm (in)
kg(lb)

170x70 (6.7x2.8)
0.5 (1.1)
PS, Light Grey/ Semi-transparent
Ceiling
Aluminum
Aluminum
N-Female
Indoor
176x176x152 (6.9x6.9x6.0)
0.6 (1.3)

mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

1880MHz

2170MHz

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

66

2500MHz

Issued: Aug09
Control: 3-1-0
1/1

Indoor Omni-directional Ceiling Mounted Antenna


IXD-360V03NN(05)

V-Pol, 670-960/1710-2700, 360, 2/4dBi

Technical Specifications
Electrical
Frequency Range

MHz

Gain (Peak)
Polarization
Power Handling

dBi

Beamwidth

670-696

696-806

VSWR
3rd Order Intermodulation @ 2x33 dBm
Impedance

17102500

25002700
4

Vertical
100

W
Vertical
Horizontal

806-960

100 - 120

deg

30 - 65
360

< 2.5:1

< 2.0:1

< 1.5:1

dBc

<-150
50

mm(in)
kg(lb)

208x115 (8.2x4.5)
0.4 (0.88)
ABS, white
Ceiling mounted (via handle nut or via 3 screws)
Aluminum
Aluminum
N-Female
Indoor

Mechanical
Dimensions, Diameter x Depth
Weight
Radome Material and Color
Mount
Reflector Material
Radiating Element Material
Connector Type
Environmental Class

Antenna Patterns

Vertical
pattern

Horizontal
pattern

880MHz

1710MHz

2300MHz

2690MHz

Installation Plots

Installation via handle nut

Installation via 3 screws

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

67

Issued: Aug12
Control: 0-0-4
1/1

I
Indoor
Om
mni-dire
ectional Ceiling
C
M
Mounted
Antenna
A
I
IXD-360V
V03NN(U))

VPol, 806
6-960/1710--2700, 360, 2.0/4.0dBi

Technicall Specifica
ations
Electrica
al
Frequency Ra
ange
Gain
Polarization
Power Handliing
Beamwidth

MHz
dBi

806 - 960
0
2.0

1710 - 2500
Verrtical
1
100

W
Verttical
Horizontal

VSWR
3rd Order Inttermodulation
n @ 2x33 dBm
m
Impedance

deg

2
2500 - 2700
4.0

100 - 120
0

30 - 65
360
3
< 1.5:1
1
< -140
5
50

dBc

Mechanic
cal
Dimensions, Diameter x Depth
Weight
Radome Mate
erial and Color
Mount
Reflector Matterial
Radiating Ele
ement Material
Connector Ty
ype
Environmenta
al Class

208x115 (8.2x4.5)
0.4 (0.88)
(
ABS,, white
Ceiling Mounted
Alum
minum
Alum
minum
N-Fe
emale
Ind
door

mm(in)
kg(lb)

Antenna Patterns

Vertical
pattern

Horizontal
pattern

17
710MHz

960MHz

Information contained
c
in this documentt is subject to confirmation at time of ord
dering.
http://www.com
mba-telecom.com

68

2500M
MHz

Issued: June12
Control: 3-0--3
1/1

Indoor Omni-directional Ceiling Mounted Antenna


IXD-360VH03NT

V-Pol, 806-960/1710-2700, 360, 2/4dBi


H-pol, 1710-2700, 360, 4dBi

Technical Specifications
Electrical
Frequency Range
Gain
Polarization
Horizontal Beamwidth
Vertical Beamwidth
VSWR
Isolation
3rd Order Intermodulation @ 2x33 dBm
Power Handling
Impedance

MHz
dBi
deg
deg

806-960
2
Vertical
100-120

dB
dBc
W

1710-1880

1850-2700
4
Vertical&Horizontal
360
40-65
2.0:1
22
<-140
50
50

Mechanical
Dimensions, Dia x H
Weight
Radome Material
Mount
Reflector Material
Connector Type
Environmental Class
Shipping Dimensions, HxWxD
Shipping Weight

178x112 (7.0x4.4)
0.42 (1.1)
ABS
Ceiling, via hole (standard)
Aluminum
2 x N-Female
Indoor
175x175x175 (6.9x6.9x6.9)
0.5 (1.1)

mm (in)
kg(lb)

mm (in)
kg (lb)

Antenna Pattern

Vertical
pattern

Horizontal
pattern

960MHz

1710MHz

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

69

2500MHz

Issued: Nov12
Control: 0-0-5
1/1

AISG Control Cable


00-KX02(yy) (yy=cable length in meter)
Features and Product Description

A 5-core cable use for connection between AISG antenna line devices
Compliance with AISG1.1 and AISG2.0
8-pin Circular connector type
Weather resistance
Supply in various length

Technical Specifications
Electrical
Operating Voltage

250

Operating Current @40C

5 (Conform to IEC60512-3)

Pulsating Voltage

1200 (Conform to IEC60664-1)

Insulation Resistance

>3x109 (Conform to IEC60512-2 Test 3a)

<5 (Conform to IEC60512-2 Test 2a)

Contact Resistance

Mechanical
Cable Specification

2C x 0.32 + 3C x 0.75
2 x 8 pin circular connector, 1 Male + 1 Female
(Conform to IEC60130-9)

Connector Type
Operating Temperature

Operating Humidity

-40 to +85
95

Environmental Class

IP67
Note: Measurements taken at room temperature, unless otherwise stated.

Part Numbers
00-KX02(0.5)

m (in)

00-KX02(01)

m (in)

0.5 (19.7)
1 (39.4)

00-KX02(03)

m (in)

3 (118.1)

00-KX02(05)

m (in)

5 (196.9)

00-KX02(10)

m (in)

10 (393.7)

00-KX02(20)

m (in)

20 (787.4)

00-KX02(30)

m (in)

30 (1,181.1)

00-KX02(40)

m (in)

40 (1,574.8)

00-KX02(50)

m (in)

50 (1,968.5)

00-KX02(60)

m (in)

60 (2,362.2)

00-KX02(70)

m (in)

70 (2,755.9)

00-KX02(80)

m (in)

80 (3,149.6)

Connector Outline Drawing


Signal
1
2
3
4
5
6
7
8
Female

+12VDC nominal
Not connected
RS485 B
Not connected
RS485 A
10V-30V DC
DC Return
Not connected

Male

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

70

Issued: Jun12
Control: 3-1-1
1/1

RCU-003
Remote Control Unit
Features

AISG v1.1 Compliance


Connection to AISG Compatible CCU, TMAs and Smart Bias Tee
Industry standard Bus RS485
Compact and light weight

Technical Specifications
Electrical
Connectors to CCU

8 pin connector, Male, conform to AISG Layer 1

Connectors to RCU

8 pin connector, Female, conform to AISG Layer 1

Power Supply
Power Consumption

+10~+30 DC

< 1 (stand by); < 10 (operating)

Protocol to CCU/TMA

HDLC hex-code command set, conform to AISG Layer 2

Adjustment Time
Adjustment Cycles

30

sec

> 50,000

Mechanical
Dimensions, HxWxD
Weight

170x52x47 (6.7x2.0x1.8)

mm (in)

0.46 (1.0)

kg (lb)

Housing Material and Color


Operating Temperature

Aluminum, Light Gray


o

-40 to +60

Environment Class

IP24

Side Views

Top View of RCU

Bottom View of RCU

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

71

Issued: 10Apr10
Control: 3-0-1
1/1

RCU-V5002
Remote Control Unit
Features

AISG v2.0 Compliance


Compatible with Ericsson RBS3206 / RBS3418 and firmware version P6.1
Compatible with Nokia Siemens Flexi WCDMA Node B and firmware version
WN4.0.6.7-273
Compatible with Huawei DBS3900
Compact and light weight
IP65 protection class

Technical Specifications
Electrical
Connectors to CCU

8 pin connector, Male, conform to AISG Layer 1

Connectors to RCU

8 pin connector, Female, conform to AISG Layer 1

Power Supply

+10~+30 DC

Power Consumption

< 1 (stand by); < 10 (operating)

Protocol to CCU/TMA

HDLC hex-code command set, conform to AISG Layer 2

Adjustment Time
Adjustment Cycles

sec

30
> 50,000

Mechanical
Dimensions, HxWxD
Weight

mm (in)

170x52x47 (6.7x2.0x1.8)

kg (lb)

0.46 (1.0)

Housing Material and Color


Operating Temperature

Aluminum, Light Gray


o

-40 to +60

Environment Class

IP65

*Note: RCU requires power supply >+24VDC to work optimally under low temperature condition of <-10C.

Side Views

Top View of RCU

Bottom View of RCU

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

72

Issued: Feb11
Control: 3-0-2
1/1

CCU-001AG, CCU-003AG
RET Central Control Unit. Hardware version 2.0
Features

Compliant with AISG 1.1 & 2.0 standards


Designed specifically to interface with AISG compliant
actuators
Web-based application
Built-in watchdog timer and supports USB 2.0
Built-in LPD (Lightning Protection Device)
Wall/Rack mountable
Self-diagnosable
With over load, surge, and short circuit protection
Available in single or three AISG port version
Compliant with CE, FCC and RoHS standards

Picture shows CCU-003AG

Technical Specifications
Electrical
AISG Connectors

CCU-001AG

1 x 8 pin connector, Female, conform to AISG Layer 1

CCU-003AG

3 x 8 pin connectors, Female, conform to AISG Layer 1


1 x +28VDC/ max 1.7A, or 1 x +13VDC/ max 3.3A

Power Supply to AISG Devices

Power Supply Input

-48 DC/max 1.5A

Total Output Power

50W

Software Selectable

Alarm Interface

3 outputs (Open collector); 1 input (Open/Close)

LED Indicators

Alarm, Run, Power

Interface to RCU/TMA

RS-485 / Power Supply

Protocol to RCU/TMA

HDLC hex-code command set, conform to AISG Layer 2

Max. Number of RET*

Up to 24 RCUs (depending on cable configuration)

Max. Number of TMA*

Up to 6 TMAs (depending on cable configuration)

Interface for Remote Control

Ethernet 10/100M adaptable

Communication Ports

RS-232, USB 2.0

Protocols to BTS

TCP/IP, HTTP/HTML, SNMP, FTP, Telnet

Protection

Built-in LPD, Over Load, Surge, Short Circuit

Mechanical
Mounting
Dimensions, HxWxD
Weight

1U 19 inch rack-mount or wall mount


mm

44x220x185

kg

1.5

RS232 Connector

9-PIN Mini-DIN PS/2

Housing Material and Color


Operating Temperature
Operating Humidity
Packing Size
Shipping Weight (Approx)

Aluminum, Light Gray


C

0 to +55

< 95

mm

83x280x253

kg

1.9

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

73

Issued: Nov 11
Control: 3-1-0
1/2

CCU-001AG, CCU-003AG
RET Central Control Unit. Hardware version 2.0
System Structure

Antennas

R
C
U

R
C
U

COMETS
Ethernet

R
C
U

AISG Cables
Power
Ethernet

RS232

Basestation

IP Network

Notebook (on-site control)


Note: Comba COMETS is a software tool that provides comprehensive features for OMC. For more information, please kindly refer to the
COMETS datasheet.

Mounting Guide

Rack/Add Ear

Wall/Side

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

74

Wall/Front

Issued: Nov 11
Control: 3-1-0
2/2

Single 850MHz Tower Mounted Amplifier


TA-C12FS03
Features

Balanced LNA design and power failure bypass for high reliability
Alarm management: DC current load simulation
Light weight and compact design
Salt spray resistance, IP66
Built-in lightning protection and vented enclosure design
EMP protection with excellent MTBF

Product Description
The TA-C12FS03 is a single 850MHz tower mounted amplifier designed for use with a vertical or cross-pole antenna. The
unit is installed near the antenna at the tower top to improve receiver sensitivity of the base station. The usage of
TA-C12FS03 will result in an increase of successful call attempts, reduction of call drops, maximized data transmission
rate, improved call quality and extended handset talk time. Quality improvements will lead to increased traffic volume and
user satisfaction, hence increasing network revenue. It is recommended for use in new network roll-outs to minimize base
station count, or for upgrading of existing base stations to improve signal quality and drop call performance.
The TA-C12FS03 comprises high quality band-pass filters, low noise amplifiers (LNA), bias tee, and lightning protection
and by-pass circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault
in the system.
Power is supplied via external bias tees that connect between the TA-C12FS03 and the PDM. Each PDM is constructed into
a 19 1U form factor, and can provide power for up to six units of TA-C12FS03.

Typical Block Diagram


To Antenna
ANT Port

Rx1 Fil

LNA

LNA

LNA Alarm
Generation Unit

RxBypass

Tx Fil
Rx2 Fil

Bias Tee

BTS Port

Bias Tee
+12V
BTS

PDM

Alarm
To BTS

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

75

Issued: Nov.11
Control: 3-2-0
1/2

Single 850MHz Tower Mounted Amplifier


TA-C12FS03
Technical Specifications
Electrical - Uplink
Frequency Range

MHz

Bandwidth

MHz

25

dB

12 1

Noise Figure

dB

1.8 (typ. 1.4)

Pass Band Ripple

dB

1.0

Insertion Loss in By-pass Mode

dB

1.8

System Gain

Output 3rd Order Intercept Point (OIP3)


Return Loss
Alarm Management

dBm

Normal Operation
By-pass Mode
Minor Alarm
Major Alarm

dB
mA

824-849

22
18
14
23020mA(Operation)
33020mA(By-pass Mode)

ns

200

Frequency Range

MHz

869-894

Bandwidth

MHz

25

dB

0.6

Group Delay

Electrical Downlink

Insertion Loss

dB

18

Absolute Maximum RF Input Power

dBm

52 (CW); 58.6 (Peak)

7th order PIM

dBm

-110 (2 TX carriers at +43dBm)

Group Delay

ns

70

Return Loss

Power, Mechanical & Environmental


Connectors Type

7/16 DIN-Female

Operating Voltage

+10 to +15

Operating Current

mA

120@+12V

1.5

Power Consume

Dimensions, LxWxH (excluding connector and mounting


mm (in)
brackets)
Weight

kg (lb)

Mounting

Light Grey

Enclosure Material

Aluminum

Operating Temperature

Operating Humidity

EMC

MTBF

4(8.8)
Mast mounting: with clamp set

Enclosure Color

Lightning Protection
Environmental Class

223x194x60(8.8x7.7x2.4)

-40 to +65
95
ETS 300 342-3

RF

8kA, 8/20s
IP66
hr

> 1,000,000

Note: Measurements taken at room temperature, unless otherwise stated.

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

76

Issued: Nov.11
Control: 3-2-0
2/2

Twin 850MHz AISG2.0 Tower Mounted Amplifier


TA-C12FDA-A
Features

Two TMA units in one enclosure


Balanced LNA design and power failure bypass for high reliability
Alarm management: DC current load simulation will be generated when AISG
signal is not available
Light weight and compact design
Salt spray resistance, IP66
Built-in lightning protection and vented enclosure design
EMP protection with excellent MTBF
AISG 2.0 Compatible

Product Description
The TA-C12FDA-A is a 850MHz twin tower mounted amplifier for both main and diversity branch and fits with cross-pole
antennas. The unit is installed near the antenna at the tower top to improve receiver sensitivity of the base station. The
usage of TA-C12FDA-A will result in an increase of successful call attempts, reduction of call drops, maximized data
transmission rate, improved call quality and extended handset talk time. Quality improvements will lead to increased
traffic volume and user satisfaction, hence increasing network revenue. It is recommended for use in new network
roll-outs to minimize base station count, or for upgrading of existing base stations to improve signal quality and drop call
performance.
The system comprises high quality band-pass filters, low noise amplifiers (LNA), bias tee, and lightning protection and
by-pass circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault in the
system.

Typical Block Diagram

ANT0

ANT1
DC GND

DC GND

Rx1
Filter

RET
7/8 RF Cable

Rx1
Filter

TAC12FDA-A

RxBypass

RxBypass

LNA

The top of
the tower

RCU

RCU

Multi-cable
7/8 RF Cable

LNA

LNA
LNA

Tx
Filter

Tx
Filter

Supervision

and
Alarm
and
Alarm
Generation

Rx2
Filter

BTS 0

AISG
DC
Lightning
Protection

RS485B

Unit
Unit
DC
RS485A

Bias Tee
and Lightning
Protection

7/8 RF Cable

Rx2
Filter

Bias Tee
and Lightning
Protection

AISG
DC

BTM4S2

From CCU
or BTS

The root of
the tower

BTS

Modem

To RCU

BTS 1

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

77

Issued: Nov.11
Control: 3-0-0
1/2

Twin 850MHz AISG2.0 Tower Mounted Amplifier


TA-C12FDA-A
Technical Specifications
Electrical - Uplink
Frequency Range

MHz

Bandwidth

MHz

25

dB

12 1

Noise Figure

dB

1.8 (typ. 1.4)

Pass Band Ripple

dB

1.0

Insertion Loss in By-pass Mode

dB

1.8

System Gain

Output 3rd Order Intercept Point (OIP3)


Return Loss

824-849

22

dBm

Normal Operation
By-pass Mode

Group Delay

18

dB

14
200

ns

Alarm Management in AISG Mode

Compatible with AISG 2.0

Electrical Downlink
Frequency Range

MHz

Bandwidth

MHz

25

dB

0.6

Insertion Loss

869-894

dB

18

Absolute Maximum RF Input Power

dBm

52 (CW); 58.6(Peak)

7th order PIM

dBm

-110 (2 TX carriers at +43dBm)

Group Delay

ns

70

Return Loss

Power, Mechanical & Environmental


Modem Characteristics

According to AISG Standard 2.0 (Data rate:9.6kB)


ANT/BTS

Connectors Type

7/16 DIN-Female
8-pin Female IEC60130-9
(Pin3:RS485B, Pin5:RS485A,Pin6:+24V, Pin7:DC
return; other pins: not connected)

AISG

Operating Voltage

10 to +30

Operating Current

mA

150 20@+24V

Power Consume

Operation Mode

DC/OOK BTS0 or BTS1

Dimensions, LxWxH (excluding connector and mounting


mm (in)
brackets)
Weight
kg (lb)

223x194x119 (8.8x7.7x4.7)
8 (17.6)

Mounting

Mast mounting: with clamp set

Enclosure Color

Light Grey

Enclosure Material

Aluminum

Operating Temperature

-40 to +65

Operating Humidity

95

EMC

ETS 300 342-3


RF

Lightning Protection

8kA, 8/20s
RS485A. RS485 B Different mould 3kA. Common
mould 5kA, DC and GND Different mould 3kA
IP66

AISG

Environmental Class
MTBF

hr

> 1,000,000 per unit

Note: Measurements taken at room temperature, unless otherwise stated.

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

78

Issued: Nov.11
Control: 3-0-0
2/2

Single 900MHz Tower Mounted Amplifier


TA-G12FS02
Features

Balanced LNA design and power failure bypass for high reliability
Alarm management: DC current load simulation
Light weight and compact design
Salt spray resistance, IP66
Built-in lightning protection and vented enclosure design
EMP protection with excellent MTBF

Product Description
The TA-G12FS02 is a GSM900 tower mounted amplifier designed for use with a vertical or cross-pole antenna. The unit is
installed near the antenna at the tower top to improve receiver sensitivity of the base station. The usage of TA-G12FS02
will result in an increase of successful call attempts, reduction of call drops, maximized data transmission rate, improved
call quality and extended handset talk time. Quality improvements will lead to increased traffic volume and user
satisfaction, hence increasing network revenue. It is recommended for use in new network roll-outs to minimize base
station count, or for upgrading of existing base stations to improve signal quality and drop call performance.
The TA-G12FS02 comprises high quality band-pass filters, low noise amplifiers (LNA), bias tee, lightning protection and
by-pass circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault in the
system.
Power is supplied via external bias tees that connect between the TA-G12FS02 and the PDM. Each PDM is constructed into
a 19 1U form factor, and can provide power for up to six units of TA-G12FS02.

Typical Application Block Diagram


To Antenna
ANT Port

Rx1 Fil

LNA

LNA

LNA Alarm
Generation Unit

RxBypass

Tx Fil
Rx2 Fil

Bias Tee

BTS Port

Bias Tee
+12V
PDM

BTS

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

79

Alarm
To BTS

th

Issued: 17 Nov
Control: 3-2-0
1/2

Single 900MHz Tower Mounted Amplifier


TA-G12FS02
Technical Specifications
Electrical - Uplink
Frequency Range

MHz

Bandwidth

MHz

25

dB

12 1

Noise Figure

dB

1.8 (typ. 1.4)

Pass Band Ripple

dB

1.0

Insertion Loss in By-pass Mode

dB

1.8

dBm

22

System Gain

Output 3rd Order Intercept Point (OIP3)

890-915

Normal Operation

dB

18

By-pass Mode

dB

14

Minor Alarm

mA

> 230 20 (Operation)

Major Alarm

mA

> 330 20 (By-pass Mode)

Frequency Range

MHz

935-960

Bandwidth

MHz

25

dB

0.5

Return Loss
Alarm Management

Electrical - Downlink

Insertion Loss

dB

18

Absolute Maximum RF Input Power

dBm

52 (CW); 58.6 (Peak)

Inter-modulation Products in RX Band

dBm

-110 (2 TX carriers at +43dBm)

Return Loss

Power, Mechanical & Environmental


Operating Voltage

+10 to +15

Operating Current

mA

120 @+12V

1.5

mm(in)

246x182x58 (9.7x7.2x2.3)

Power Consume
Dimensions, LxWxH (excluding connectors & mounting
brackets)
Weight

kg(lb)

3.5 (7.7)
Wall mounting: with 4 screws

Mounting

Mast mounting: with clamp set

Connector Type

7/16 DIN-Female

Enclosure Color

Light Grey

Enclosure Material

Aluminum

Operating Temperature

Operating Humidity

EMC

95
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s

Lightning Protection
Environmental Class
MTBF

-40 to +65

IP66
hr

> 1000,000

Note: Measurements taken at room temperature, unless otherwise stated.

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

80

th

Issued: 17 Nov
Control: 3-2-0
2/2

Full band Single 900MHz Tower Mounted Amplifier


TA-E12FS
Features

Balanced LNA design and power failure bypass for high reliability
Alarm management: DC current load simulation
Light weight and compact design
Salt spray resistance, IP66
Built-in lightning protection and vented enclosure design
EMP protection with excellent MTBF

Product Description
The TA-E12FS is an EGSM900 tower mounted amplifier designed for use with a vertical or cross-pole antenna. The unit is
installed near the antenna at the tower top to improve receiver sensitivity of the base station. The usage of TA-E12FS will
result in an increase of successful call attempts, reduction of call drops, maximized data transmission rate, improved call
quality and extended handset talk time. Quality improvements will lead to increased traffic volume and user satisfaction,
hence increasing network revenue. It is recommended for use in new network roll-outs to minimize base station count, or
for upgrading of existing base stations to improve signal quality and drop call performance.
The TA-E12FS comprises high quality band-pass filters, low noise amplifiers (LNA), bias tee, lightning protection and
by-pass circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault in the
system.
Power is supplied via external bias tees that connect between the TA-E12FS and the PDM. Each PDM is constructed into a
19 1U form factor, and can provide power for up to six units of TA-E12FS.

Typical Application Block Diagram


To Antenna
ANT Port

Rx1 Fil

LNA

LNA

LNA Alarm
Generation Unit

RxBypass

Tx Fil
Rx2 Fil

Bias Tee

BTS Port

Bias Tee
+12V
BTS

PDM

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

81

Alarm
To BTS

th

Issued: 17 Nov 11
Control: 3-2-0
1/2

Full band Single 900MHz Tower Mounted Amplifier


TA-E12FS
Technical Specifications
Electrical - Uplink
Frequency Range

MHz

Bandwidth

MHz

35

dB

12 1

Noise Figure

dB

1.8 (typ. 1.4)

Pass Band Ripple

dB

1.0

Insertion Loss in By-pass Mode

dB

1.9

System Gain

Output 3rd Order Intercept Point (OIP3)


Return loss

Active Mode

880-915

dBm

22

dB

18

Bypass Mode

dB

14

Minor Alarm

mA

230 (Operation)

Major Alarm

mA

330 (By-pass Mode)

Frequency Range

MHz

925-960

Bandwidth

MHz

35

dB

0.6

Alarm Management

Electrical - Downlink

Insertion Loss

dB

18

Absolute Maximum RF Input Power

dBm

52 (CW); 58.6 (Peak)

Inter-modulation Products in RX Band

dBm

-110 (2 TX carriers at +43dBm)

Return Loss

Power, Mechanical & Environmental


Operating Voltage

+10 to +15

Operating Current

mA

120 10 @+12V

mm(in)

252x180x61 (9.9x7.1x2.4)

Power Consume
Dimensions, LxWxH (excluding connectors & mounting
brackets)
Weight

3.5 (7.7)

kg(lb)

Wall mounting: with 4 screws

Mounting

Mast mounting: with clamp set

Connector Type

7/16 DIN-Female

Enclosure Color

Light Grey

Enclosure Material

Aluminum

Operating Temperature

-40 to +65

Operating Humidity

95

EMC

ETS 300 342-3

Lightning Protection

Comply with IEC 61000-4-5; 8kA, 8/20s

Environmental Class
MTBF

IP66
hr

> 1,000,000

Note: Measurements taken at room temperature, unless otherwise stated.

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

82

th

Issued: 17 Nov 11
Control: 3-2-0
2/2

FFull Band
d Twin 90
00MHz AIS
SG2.0 Tower Mou
unted
A
Amplifier
r
T
TA-E12FD
DA-A
Features
s

Two TMA
A units in one enclosure
Power fa
ailure bypass for
f high reliab
bility
SG
Alarm management: DC
D current loa
ad simulation will
w be genera
ated when AIS
signal is not available
Light weight and comp
pact design
Salt spra
ay resistance, IP66
Built-in lightning prote
ection and ven
nted enclosure design
EMP prottection with excellent MTBF
F
AISG 2.0
0 Compatible

Product Descriptiion
cross-pole
e
w
The TA-E12FD
DA-A is an EGSM900 twin to
ower mounted
d amplifier for both main and
d diversity branch and fits with
e station. The
e
antennas. Th
he unit is insta
alled near the antenna at th
he tower top to
o improve rec
ceiver sensitivity of the base
aximized data
call drops, ma
usage of TA--E12FDA-A wiill result in an
n increase of successful ca
all attempts, reduction
r
of c
d to increased
ments will lead
transmission rate, improve
ed call quality
y and extende
ed handset ta
alk time. Quality improvem
k
ed for use in new network
traffic volume and user satisfaction, hence increasing network revenue. It is recommende
y and drop call
roll-outs to minimize
m
base station count,, or for upgrad
ding of existing base station
ns to improve signal quality
performance.
n and by-pass
s
ning protection
The system comprises high
h quality band-pass filters, lo
ow noise amplifiers (LNA), bias
b
tee, lightn
circuitries. Th
he LNA bypass
s circuitry is ac
ctivated when the DC supply
y is switched off
o or when there is a fault in the system.

Typical Applicatio
A
on Block Diagram
D

A
ANT0

ANT1

The top off


the tower

DC GND
G

DC GND

ET
RE
Rx1
Filterr

Rx1
Filter

7/8 RF Cable

RxBypass

TAE12FDA-A

RxBypass

RCU

RCU

Multi-cable
LNA

L
LNA

7/8 RF Cable

LNA
LNA

Tx
Filter

Tx
Filter

Supervision
and
and
Alarm
Alarm
Generation

Rx2
Filter
F

BT
TS 0

RS485B

AISG
DC
Lightning
Protection

DC
RS485A

Bias Tee
and Lightning
Protection

Rx2
Filter

Unit
Unit

7/8 RF Cable
B
Bias
Tee
and Lightning
Prrotection

AISG
A
D
DC

BTM1S2
M

From CCU
or Node B

The root of
the tower

Node B

Mode
em
To RCU

BTS 1

Information con
ntained in this document
d
is sub
bject to confirma
ation at time of ordering.
o
http://www.com
mba-telecom.com

83

th

ed: 17 Nov 11
Issue
Control: 3-1--0
1/2

FFull Band
d Twin 90
00MHz AIS
SG2.0 Tower Mou
unted
A
Amplifier
r
T
TA-E12FD
DA-A
Technica
al Specific
cations
Electrical - Uplink
k
Frequency Ra
ange

MHz

Bandwidth

MHz

3
35

System Gain

dB

12
21

Noise Figure

dB

1.8 (ttyp. 1.4)

Pass Band Ripple

dB

1.0

Insertion Loss in By-pass Mode


M

dB

1.9

Output 3rd Orrder Intercept Point (OIP3)


Return Loss

880
0-915

22

dBm

Normall Operation
By-pass Mode

18

dB

14

Alarm Management

Compatible w
with AISG 2.0
0

Electrical Down
nlink
Frequency Ra
ange

MHz

Bandwidth

MHz

3
35

dB

0.6

Insertion Loss

925
5-960

dB

18

Absolute Max
ximum RF Input Power

dBm

50 (CW); 58.6 (Peak)

Inter-modula
ation Products in Rx Band

dBm

-110 (2 TX carrriers at +43d


dBm)

Return Loss

Power, Mechanica
M
al & Envirronmenta
al
Modem Chara
acteristics

According to
t AISG Stand
dard 2.0 (Data
a rate:9.6kB)
RF

Connectors Type
T

7/16 DIN-Female
8-pin Female IEC60130-9
9
(Pin6:+24V
V, Pin3:RS485
5B, Pin5:RS48
85A, Pin7:DC
return; other pin
ns: not connec
cted)

AISG

Operating Voltage
Operating Cu
urrent with Sin
ngle Port
Power Consume

+10 to +30

mA

150 2
20@+24V
4

Operation Mo
ode

DC/OOK
K Node B0

Dimensions, LxWxH (exclu


uding connecttor and mountting
mm (in)
brackets)
Weight

252x179x11
19 (9.9x7x4.7))

kg (lb)

6.5 ((14.3)
W
Wall
mounting
g: with 4 screw
ws

Mounting

M
Mast
mounting
g: with clamp set

Enclosure Collor

Lightt Grey

Enclosure Material

Alum
minum

Operating Tem
mperature

Operating Humidity

-40 tto +65


95

EMC

ETS 30
00 342-3
RF

Lightning Protection

8kA, 8/20s
RS485A. RS485
R
B Differrent mould 3k
kA. Common
mould 5k
kA, DC and GND Different mould
m
3kA

AISG

Environmenta
al Class
MTBF

IP
P66
hr

> 1,000,000(per unit)

Note: Measurements taken at room temperature, unless oth


herwise stated.

Information con
ntained in this document
d
is sub
bject to confirma
ation at time of ordering.
o
http://www.com
mba-telecom.com

84

th

Issue
ed: 17 Nov 11
Control: 3-1--0
2/2

Single 1800MHz Tower Mounted Amplifier


TA-D12FS
Features

Balanced LNA design and power failure bypass for high reliability
Alarm management: DC current load simulation
Light weight and compact design
Salt spray resistance, IP66
Built-in lightning protection and vented enclosure design
EMP protection with excellent MTBF

Product Description
The TA-D12FS is a DCS1800 tower mounted amplifier designed for use with a vertical or cross-pole antenna. The unit is
installed near the antenna at the tower top to improve receiver sensitivity of the base station. The usage of TA-D12FS will
result in an increase of successful call attempts, reduction of call drops, maximized data transmission rate, improved call
quality and extended handset talk time. Quality improvements will lead to increased traffic volume and user satisfaction,
hence increasing network revenue. It is recommended for use in new network roll-outs to minimize base station count, or
for upgrading of existing base stations to improve signal quality and drop call performance.
The TA-D12FS comprises high quality band-pass filters, low noise amplifiers (LNA), bias tee, and lightning protection and
bypass circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault in the
system.
Power is supplied via external bias tees that connect between the TA-D12FS and the PDM. Each PDM is constructed into
a 19 1U form factor, and can provide power for up to six units of TA-D12FS.

Typical Application Block Diagram


To Antenna
ANT Port

Rx1 Fil

LNA

LNA

LNA Alarm
Generation Unit

RxBypass

Tx Fil
Rx2 Fil

Bias Tee

BTS Port

Bias Tee
+12V
PDM

BTS

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

85

Alarm
To BTS

th

Issued: 17 Nov11
Control: 3-2-0
1/2

Single 1800MHz Tower Mounted Amplifier


TA-D12FS
Technical Specifications
Electrical - Uplink
Frequency Range

MHz

Bandwidth

MHz

75

dB

12 1

Noise Figure

dB

1.9 (typ. 1.5)

Pass Band Ripple

dB

1.2

Insertion Loss in By-pass Mode

dB

2.2

Output 3rd Order Intercept Point

dBm

25

System Gain

Return Loss

Normal Operation
Bypass Mode

1710-1785

18

dB

14

mA

70 or 155

Frequency Range

MHz

1805-1880

Bandwidth

MHz

75

dB

0.6

Alarm Management

Alarm window

Electrical - Downlink

Insertion Loss

dB

18

Absolute Maximum RF Input Power

dBm

52 (CW); 58.6 (Peak)

Inter-modulation Products in RX Band

dBm

-110 (2 TX carriers at +43dBm)

Return Loss

Power, Mechanical & Environmental


Operating Voltage

+10 to +15

Operating Current

mA

110 10 @12V

1.5

mm(in)

250x121x60 (9.8x4.8x2.4)

Power Consume
Dimensions, LxWxH (excluding connectors & mounting
brackets)
Weight

3 (6.6)

kg(lb)

Wall mounting: With 4 screws

Mounting

Mast mounting: With clamp set

Connector Type

7/16 DIN-Female

Enclosure Color

Light Grey

Enclosure Material

Aluminum

Operating Temperature

Operating Humidity

-40 to +65
95

EMC

ETS 300 342-3


Comply with IEC 61000-4-5; 8kA, 8/20s

Lightning protection
Environmental Class
MTBF

IP66
hr

> 1,000,000

Note: Measurements taken at room temperature, unless otherwise stated.

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

86

th

Issued: 17 Nov11
Control: 3-2-0
2/2

Twin 1800MHz Tower Mounted Amplifier


TA-D12FD-03
Features

Two TMA units in one enclosure


Balanced LNA design and power failure bypass for high reliability
Alarm management: DC current load simulation
Light weight and compact design
Salt spray resistance
IP66 with Gore Tex ventilation membrane
Built-in lightning protection and vented enclosure design
EMP protection with excellent MTBF

Product Description
The TA-D12FD-03 is a full band DCS1800 twin tower mounted amplifier for both main and diversity branch and fits with
cross-pole antennas. The unit is installed near the antenna at the tower top to improve receiver sensitivity of the base
station. The usage of TA-D12FD-03 will result in an increase of successful call attempts, reduction of call drops, maximized
data transmission rate, improved call quality and extended handset talk time. Quality improvements will lead to increased
traffic volume and user satisfaction, hence increasing network revenue. It is recommended for use in new network
roll-outs to minimize base station count, or for upgrading of existing base stations to improve signal quality and drop call
performance.
The system comprises high quality band-pass filters, low noise amplifiers (LNA), bias tee, lightning protection and by-pass
circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault in the system.
Power is supplied via external bias tees that connect between the TA-D12FD-03 and the PDM. Each PDM is constructed
into a 19 1U form factor, and can provide power for up to three units of TA-D12FD-03.

Typical Application Block Diagram


To Antenna

To Antenna

ANT0 Port

Rx1 Fil

LNA

Tx Fil
Rx2 Fil

Rx1 Fil

LNA

LNA

LNA0 Alarm
Generation Unit
LNA1 Alarm
Generation Unit

RxBypass

ANT1 Port

Tx Fil
Rx2 Fil

Bias Tee

Bias Tee

BTS0 Port

Bias Tee

RxBypass

LNA

BTS1 Port

Bias Tee
+12V
BTS

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

87

PDM

Alarm
To BTS

th

Issued: 17 Nov11
Control: 3-1-0
1/2

Twin 1800MHz Tower Mounted Amplifier


TA-D12FD-03
Technical Specifications
Electrical - Uplink
Frequency Range

MHz

Bandwidth

MHz

75

dB

12 1

Noise Figure

dB

1.9 (typ. 1.5)

Pass Band Ripple

dB

1.0

Insertion Loss in By-pass Mode

dB

2.2

System Gain

Output 3rd Order Intercept Point (OIP3)


Return Loss

dBm

Normal Operation
By-pass Mode

dB

1710-1785

25
18
14

mA

230 (Operation)
330 (By-pass Mode)

Frequency Range

MHz

1805-1880

Bandwidth

MHz

75

dB

0.6

Alarm Management

Minor Alarm
Major Alarm

Electrical - Downlink

Insertion Loss
Return Loss
Absolute Maximum RF Input Power
Inter-modulation Products in RX Band

dB

18

dBm
dBm

52 (CW); 58.6 (Peak)


-110 (2 TX carriers at +43dBm)

Power, Mechanical & Environmental


Operating Voltage
Operating Current per Port
Power Consume per Port
Dimensions, LxWxH (excluding connectors & mounting
brackets)
Weight

+10 to +15

mA

120 @+12V

1.5

mm(in)

250x224x60.5 (9.9x8.9x2.4)

kg(lb)

6 (13.2)
Wall mounting: with 4 screws

Mounting

Mast mounting: with clamp set

Connector Type

7/16 DIN-Female

Enclosure Color

Light Grey

Enclosure Material

Aluminum

Operating Temperature

Operating Humidity

EMC

95
ETS 300 342-3

Lightning Protection

Comply with IEC 61000-4-5; 8kA, 8/20s

Environmental Class
MTBF (per Unit)

-40 to +65

IP66
hr

> 1,000,000(per unit)

Note: Measurements taken at room temperature, unless otherwise stated.

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

88

th

Issued: 17 Nov11
Control: 3-1-0
2/2

Twin 1800MHz AISG2.0 Tower Mounted Amplifier


TA-D12FDA-A
Features

Two TMA units in one enclosure


Balanced LNA design and power failure bypass for high reliability
Alarm management: DC current load simulation and AISG alarm management
Light weight and compact design
Salt spray resistance
IP66 with Gore Tex ventilation membrane
Built-in lightning protection and vented enclosure design
EMP protection with excellent MTBF
3GPP/AISG 2.0 Compatible

Product Description
The TA-D12FDA-A is a full band GSM1800 twin tower mounted amplifier for both main and diversity branch and fits with
cross-pole antennas. The unit is installed near the antenna at the tower top to improve receiver sensitivity of the base
station. The usage of TA-D12FDA-A will result in an increase of successful call attempts, reduction of call drops,
maximized data transmission rate, improved call quality and extended handset talk time. Quality improvements will lead
to increased traffic volume and user satisfaction, hence increasing network revenue. It is recommended for use in new
network roll-outs to minimize base station count, or for upgrading of existing base stations to improve signal quality and
drop call performance.
The system comprises high quality band-pass filters, low noise amplifiers (LNA), bias tee, and lightning protection and
bypass circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault in the
system.
Power is supplied via external smart bias tee that connects between TA-D12FDA-A and BTS. AISG signals pass through
smart bias tee and are transmitted to other antenna line devices via TA-D12FDA-A.

Typical Application Block Diagram

ANT0

ANT1

The top of
the tower

DC GND

DC GND

RET
Rx1
Filter

Rx1
Filter

7/8 RF Cable

RCU

RxBypass

RxBypass

TA-D12FDA-A

RCU

Multi-cable
LNA

7/8 RF Cable

LNA

LNA
LNA

Tx
Filter

Tx
Filter

Supervision

and
Alarm
and
Alarm
Generation

Rx2
Filter

BTS 0

AISG
DC
Lightning
Protection

RS485B

Unit
Unit
DC
RS485A

Bias Tee
and Lightning
Protection

Rx2
Filter

7/8 RF Cable

From CCU
or BTS
The root of
the tower

Bias Tee
and Lightning
Protection

AISG
DC

BT-M4S2

BTS

Modem

To RCU

BTS 1

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

89

th

Issued: 17 Nov 11
Control: 3-0-0
1/2

Twin 1800MHz AISG2.0 Tower Mounted Amplifier


TA-D12FDA-A
Technical Specifications
Electrical - Uplink
Frequency Range

MHz

Bandwidth

MHz

75

System Gain

dB

12 1

Noise Figure

dB

1.9 (typ. 1.5)

Pass Band Gain Ripple

dB

1.0

Insertion Loss in By-pass Mode

dB

2.2

Output 3rd Order Intercept Point (OIP3)


Return Loss

1710-1785

25

dBm

Normal Operation
Bypass Mode

18

dB

14

Alarm Management in AISG Mode

Compatible with 3GPP/AISG 2.0

Electrical - Downlink
Frequency Range

MHz

Bandwidth

MHz

75

dB

0.6(typ.0.5)

Insertion Loss

1805-1880

dB

18

Absolute Maximum RF Input Power

dBm

52 (CW); 58.6 (Peak)

Inter-modulation Products in RX Band

dBm

-110 (2 TX carriers at +43dBm)

ns

50

Return Loss

Group Delay

Power, Mechanical & Environmental


Modem Characteristics

According to AISG standard 2.0 (Data rate:9.6kB)


RF

Connectors Type

7/16 DIN-Female
8-pin Female IEC60130-9
(Pin6:+24V, Pin3:RS485B, Pin5:RS485A, Pin7:DC
return; other pins: not connected)
+10 to +30

mA

160 20 @+24V

3.5
Through BTS0 Port or BTS1 Port

mm(in)

250x224x59.5 (9.8x8.8x2.4)

kg(lb)

6 (13)
Wall mounting: with 4 screws
Mast mounting: with clamp set
Light Grey

AISG

Operating Voltage
Operating Current with Single Port Power Supply
Power Consume
DC Supply
Dimensions, LxWxH (excluding connectors & mounting
brackets)
Weight
Mounting
Enclosure Color
Enclosure Material

Aluminum

Operating Temperature

Operating Humidity

-40 to +65
95

EMC

ETS 300 342-3


RF Ports

Lightning Protection

Comply with IEC 61000-4-5; 8kA, 8/20s


RS485ARS485 B Different mould 3kACommon
mould 5KA ,DC and GND Different mould 3kA

AISG Port

Environmental Class
MTBF

IP66
h

> 1,000,000(per unit)

Note: Measurements taken at room temperature, unless otherwise stated.

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

90

th

Issued: 17 Nov 11
Control: 3-0-0
2/2

Twin 1800MHz AISG1.1 Tower Mounted Amplifier


TA-D12FDA
Features

Two TMA units in one enclosure


Balanced LNA design and power failure bypass for high reliability
Alarm management: DC current load simulation
Light weight and compact design
Salt spray resistance
IP66 with Gore Tex ventilation membrane
Built-in lightning protection and vented enclosure design
EMP protection with excellent MTBF
AISG 1.1 Compatible

Product Description
The TA-D12FDA is a full band GSM1800 twin tower mounted amplifier for both main and diversity branch and fits with
cross-pole antennas. The unit is installed near the antenna at the tower top to improve receiver sensitivity of the base
station. The usage of TA-D12FDA will result in an increase of successful call attempts, reduction of call drops, maximized
data transmission rate, improved call quality and extended handset talk time. Quality improvements will lead to increased
traffic volume and user satisfaction, hence increasing network revenue. It is recommended for use in new network
roll-outs to minimize base station count, or for upgrading of existing base stations to improve signal quality and drop call
performance.
The system comprises high quality band-pass filters, low noise amplifiers (LNA), bias tee, and lightning protection and
bypass circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault in the
system.
Power is supplied via external smart bias tee that connects between TA-D12FDA and Node B. AISG signals pass through
smart bias tee and are transmitted to other antenna line devices via TA-D12FDA.

Typical Application Block Diagram

ANT0

ANT1

The top of
the tower

DC GND

DC GND

RET
Rx1
Filter

7/8 RF Cable

Rx1
Filter
RxBypass

RxBypass

TA-D12FDA

RCU

RCU

Multi-cable
LNA

LNA

7/8 RF Cable

LNA
LNA

Tx
Filter

Tx
Filter

Supervision

and
Alarm
and
Alarm
Generation

Rx2
Filter

Lightning
Protection

BTS 0

7/8 RF Cable

RS485B

DC Power

DC
RS485A

Bias Tee
and Lightning
Protection

Rx2
Filter

Unit
Unit

From CCU
or Node B
The root of
the tower

Node B

Modem

To RCU

BT-M1S

BTS 1

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

91

th

Issued: 17 Nov 11
Control: 3-2-0
1/2

Twin 1800MHz AISG1.1 Tower Mounted Amplifier


TA-D12FDA
Technical Specifications
Electrical - Uplink
Frequency Range

MHz

Bandwidth

MHz

75

dB

12 1

Noise Figure

dB

1.9 (typ. 1.5)

Pass Band Ripple

dB

1.2

Insertion Loss in By-pass Mode

dB

2.2

System Gain

Output 3rd Order Intercept Point (OIP3)


Return Loss
Alarm Management in Normal
Mode

1710-1785

25

dBm

Normal Operation
Bypass Mode
Minor Alarm

18

dB

14
> 230 20@+12V (Operation)

mA

Major Alarm

> 330 20@+12V (By-pass Mode)

Alarm Management in AISG Mode

Compatible with AISG 1.1

Electrical - Downlink
Frequency Range

MHz

Bandwidth

MHz

75

dB

0.6

Insertion Loss

1805-1880

dB

18

Absolute Maximum RF Input Power

dBm

52 (CW); 58.6 (Peak)

Inter-modulation Products in RX Band

dBm

-110 (2 TX carriers at +43dBm)

Return Loss

Power, Mechanical & Environmental


Modem Characteristics

According to AISG standard 1.1 (Data rate:9.6kB)


RF

Connectors Type

7/16 DIN-Female
8-pin Female IEC60130-9
(Pin1:+12V ,Pin3:RS485B, Pin5:RS485A, Pin7:DC
return; other pins: not connected)
+10 to +15

mA

140 10 @+12V

mA

250 10 @+12V

3.5(dual units)
DC/OOK Node B0
DC Node B1

mm(in)

250x224x60 (9.8x8.8x2.4)

kg(lb)

5 (11)
Wall mounting: with 4 screws
Mast mounting: with clamp set
Light Grey

AISG

Operating Voltage
Operating Current with Dual Ports Power Supply
Operating Current with Single Port Power Supply
(AISG Mode)
Power Consume
Operation Mode
Dimensions, LxWxH (excluding connectors & mounting
brackets)
Weight
Mounting
Enclosure Color
Enclosure Material

Aluminum

Operating Temperature

-40 to +65

Operating Humidity

EMC

RF Ports
Lightning Protection

95
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s
RS485ARS485 B Different mould 3kACommon
mould 5KA ,DC and GND Different mould 3kA

AISG Port

Environmental Class
MTBF

IP66
hr

> 1,000,000(per unit)

Note: Measurements taken at room temperature, unless otherwise stated.

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

92

th

Issued: 17 Nov 11
Control: 3-2-0
2/2

Twin 1900MHz AISG1.1 Tower Mounted Amplifier


TA-P12FDA
Features

Two TMA units in one enclosure


Balanced LNA design and power failure bypass for high reliability
Alarm management: DC current load simulation will be generated when AISG
signal is not available
Light weight and compact design
Salt spray resistance, IP66
Built-in lightning protection and vented enclosure design
EMP protection with excellent MTBF
AISG1.1 compliance

Product Description
The TA-P12FDA is a 1900 MHz twin tower mounted amplifier for both main and diversity branch and fits with cross-pole
antennas. The unit is installed near the antenna at the tower top to improve receiver sensitivity of the base station. The
usage of TA-P12FDA will result in an increase of successful call attempts, reduction of call drops, maximized data
transmission rate, improved call quality and extended handset talk time. Quality improvements will lead to increased
traffic volume and user satisfaction, hence increasing network revenue. It is recommended for use in new network
roll-outs to minimize base station count, or for upgrading of existing base stations to improve signal quality and drop call
performance.
The system comprises high quality band-pass filters, low noise amplifiers (LNA), bias tee, and lightning protection and
by-pass circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault in the
system.

Typical Block Diagram

ANT0

ANT1
The top of
the tower

DC GND

DC GND

Rx1
Filter

RET
7/8 RF Cable

Rx1
Filter

RCU

RCU

TA-P12FDA

RxBypass

RxBypass

Multi-cable
7/8 RF Cable

LNA

LNA

LNA
LNA

Tx
Filter

Tx
Filter

Supervision

and
Alarm
and
Alarm
Generation

Rx2
Filter

BTS 0

RS485B

AISG
DC
Lightning
Protection

DC
RS485A

Bias Tee
and Lightning
Protection

Rx2
Filter

Unit
Unit

Bias Tee
and Lightning
Protection

AISG
DC

From CCU
or BTS

BT-M1S
7/8 RF Cable

The root of
the tower

BTS

Modem

To RCU

BTS 1

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

93

Issued: Nov 11
Control: 3-0-0
1/2

Twin 1900MHz AISG1.1 Tower Mounted Amplifier


TA-P12FDA
Technical Specifications
Electrical Uplink
Frequency Range

MHz

Bandwidth

MHz

60

dB

12 1

Noise Figure

dB

1.9 (typ. 1.5)

Pass Band Ripple

dB

1.0

Insertion Loss in By-pass Mode

dB

2.2

System Gain

Output 3rd Order Intercept Point (OIP3)


Return Loss
Alarm Management(None
AISG mode)

1850-1910

25

dBm

Normal Operation
By-pass Mode
Minor Alarm
Major Alarm

18

dB

14
23020mA(Operation)

mA

33020mA(By-pass Mode)

ns

100

Frequency Range

MHz

1930-1990

Bandwidth

MHz

60

dB

0.6

Group Delay

Electrical Downlink

Insertion Loss

dB

18

Absolute Maximum RF Input Power

dBm

52 (CW); 58.6 (Peak)

7th order PIM

dBm

-110 (2 TX carriers at +43dBm)

Group Delay

ns

50

Return Loss

Power, Mechanical & Environmental


Modem Characteristics

According to AISG Standard 1.1 (Data rate:9.6kB)

Operating Voltage
Operating Current at single port
Power Consume

+9 to +15

mA

14010@+12V

1.8

Dimensions, LxWxH (excluding connector and mounting


mm (in)
brackets)
Weight

250x224x59.5(9.9x8.8x2.4)

kg (lb)

6(13.2)

Mounting

Mast mounting: with clamp set

Enclosure Color

Light Grey

Enclosure Material

Aluminum

Operating Temperature

Operating Humidity

-40 to +65
95

EMC

ETS 300 342-3


RF

Connectors Type

7/16 DIN-Female
8-pin AISG-Female
Pin1:+12V,Pin3:RS485B, Pin5:RS485A,
Pin6:+24V,Pin7:DC return, other pins: not connected

AISG
RF

Lightning Protection

8kA, 8/20s
RS485A. RS485 B Different mould 3kA. Common
mould 5kA, DC and GND Different mould 3kA

AISG

Environmental Class
MTBF

IP66
hr

> 1,000,000

Note: Measurements taken at room temperature, unless otherwise stated.

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

94

Issued: Nov 11
Control: 3-0-0
2/2

Twin 1900MHz AISG2.0 Tower Mounted Amplifier


TA-P12FDA-A
Features

Two TMA units in one enclosure


Balanced LNA design and power failure bypass for high reliability
Alarm management: DC current load simulation will be generated when AISG
signal is not available
Light weight and compact design
Salt spray resistance, IP66
Built-in lightning protection and vented enclosure design
EMP protection with excellent MTBF
AISG 2.0 Compatible

Product Description
The TA-P12FDA-A is a PCS1900/CDMA1900 twin tower mounted amplifier for both main and diversity branch and fits with
cross-pole antennas. The unit is installed near the antenna at the tower top to improve receiver sensitivity of the base
station. The usage of TA-P12FDA-A will result in an increase of successful call attempts, reduction of call drops, maximized
data transmission rate, improved call quality and extended handset talk time. Quality improvements will lead to increased
traffic volume and user satisfaction, hence increasing network revenue. It is recommended for use in new network
roll-outs to minimize base station count, or for upgrading of existing base stations to improve signal quality and drop call
performance.
The system comprises high quality band-pass filters, low noise amplifiers (LNA), bias tee, and lightning protection and
by-pass circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault in the
system.

Typical Application Block Diagram

ANT0

ANT1
DC GND

DC GND

Rx1
Filter

The top of
the tower

RET

Rx1
Filter

7/8 RF Cable

TAP12FDA-A

RxBypass

RxBypass

RCU

RCU

Multi-cable
LNA

LNA

7/8 RF Cable

LNA
LNA

Tx
Filter

Tx
Filter

Supervision

and
Alarm
and
Alarm
Generation

Rx2
Filter

BTS 0

RS485B

AISG
DC
Lightning
Protection

DC
RS485A

Bias Tee
and Lightning
Protection

Rx2
Filter

Unit
Unit

7/8 RF Cable
Bias Tee
and Lightning
Protection

AISG
DC

The root of
the tower

BTS

Modem

To RCU

From CCU
or Node B

BT-M1S2

BTS 1

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

95

Issued: Nov.11
Control: 3-0-1
1/2

Twin 1900MHz AISG2.0 Tower Mounted Amplifier


TA-P12FDA-A
Technical Specifications
Electrical - Uplink
Frequency Range

MHz

Bandwidth

MHz

60

dB

12 1

Noise Figure

dB

1.9 (typ. 1.5)

Pass Band Ripple

dB

1.0

Insertion Loss in By-pass Mode

dB

2.2

System Gain

Output 3rd Order Intercept Point(OIP3)


Return Loss
Alarm Management(None
AISG mode)

1850-1910

25

dBm

Normal Operation
By-pass Mode
Minor Alarm

18

dB

14
12020mA@+24V(Operation)

mA

Major Alarm

Group Delay

20020mA@+24V(By-pass Mode)
100

ns

Alarm Management in AISG Mode

Compatible with AISG 2.0

Electrical - Downlink
Frequency Range

MHz

Bandwidth

MHz

60

dB

0.6

Insertion Loss

1930-1990

dB

18

Absolute Maximum RF Input Power

dBm

52 (CW);58.6(Peak)

Inter-modulation Products in RX Band

dBm

-110 (2 TX carriers at +43dBm)

ns

50

Return Loss

Group Delay

Power, Mechanical & Environmental


Modem Characteristics

According to AISG Standard 2.0 (Data rate:9.6kB)

Operating Voltage
Operating Current with single port
Power Consume with single port
Operation Mode (Only Node B0 pass DC/OOK)
Dimensions, LxWxH (excluding connectors & mounting
brackets)
Weight

+9 to +30

mA

70 10@+24V

1.8

mm(in)

250x224x59.5 (9.8x8.8x2.3)
6 (13.2)

kg(lb)

Wall mounting: with 4 screws

Mounting

Mast mounting: with clamp set


RF

Connector Type

7/16 DIN-Female
8-pin Female IEC60130-9
(Pin6:+24V, Pin3:RS485B, Pin5:RS485A, Pin7:DC
return; other pins: not connected)

AISG

Enclosure Color

Light Grey

Enclosure Material

Aluminum

Operating Temperature

Operating Humidity

-40 to +65
95

EMC

ETS 300 342-3


RF

Lightning Protection

8kA, 8/20s
RS485A. RS485 B Different mould 3kA. Common
mould 5kA, DC and GND Different mould 3kA

AISG

Environmental Class
MTBF

IP66
hr

> 1,000,000

Note: Measurements taken at room temperature, unless otherwise stated.

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

96

Issued: Nov.11
Control: 3-0-1
2/2

Twin 2100MHz AISG2.0 Tower Mounted Amplifier


TA-W12FDA-A
Features

Two TMA units in one enclosure


Balanced LNA design and power failure bypass for high reliability
Alarm management: DC current load simulation will be generated when AISG
signal is not available
Light weight and compact design
Salt spray resistance, IP66
Built-in lightning protection and vented enclosure design
EMP protection with excellent MTBF
AISG 2.0 Compatible

Product Description
The TA-W12FDA-A is a WCDMA2100MHz twin tower mounted amplifier for both main and diversity branch and fits with
cross-pole antennas. The unit is installed near the antenna at the tower top to improve receiver sensitivity of the base
station. The usage of TA-W12FDA-A will result in an increase of successful call attempts, reduction of call drops,
maximized data transmission rate, improved call quality and extended handset talk time. Quality improvements will lead
to increased traffic volume and user satisfaction, hence increasing network revenue. It is recommended for use in new
network roll-outs to minimize base station count, or for upgrading of existing base stations to improve signal quality and
drop call performance.
The system comprises high quality band-pass filters, low noise amplifiers (LNA), bias tee, and lightning protection and
by-pass circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault in the
system.

Typical Application Block Diagram

ANT0

ANT1
DC GND

DC GND

Rx1
Filter

Rx1
Filter

RxBypass

RxBypass

LNA

LNA

LNA
LNA

Tx
Filter

Tx
Filter

Supervision
and
Alarm
and
Alarm
Generation

Rx2
Filter

BTS 0

RS485B

AISG
DC
Lightning
Protection

DC
RS485A

Bias Tee
and Lightning
Protection

Rx2
Filter

Unit
Unit

Bias Tee
and Lightning
Protection

AISG
DC

Modem
To RCU

BTS 1

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

97

Issued: Nov 11
Control: 3-0-1
1/2

Twin 2100MHz AISG2.0 Tower Mounted Amplifier


TA-W12FDA-A
Technical Specifications
Electrical - Uplink
Frequency Range

MHz

Bandwidth

MHz

60

dB

12 1

Noise Figure

dB

1.9 (typ. 1.7)

Pass Band Ripple

dB

1.0

Insertion Loss in By-pass Mode

dB

2.4

System Gain

Output 3rd Order Intercept Point (OIP3)


Return Loss

1920-1980

25

dBm

Normal Operation
By-pass Mode

Group Delay

18

dB

14
80

ns

Alarm Management in AISG Mode

Compatible with AISG 2.0

Electrical Downlink
Frequency Range

MHz

Bandwidth

MHz

60

dB

0.5

Insertion Loss

2110-2170

dB

18

Absolute Maximum RF Input Power

dBm

52 (CW); 58.6(Peak)

7th order PIM

dBm

-117 (2 TX carriers at +43dBm)

Group Delay

ns

25

Return Loss

Power, Mechanical & Environmental


Modem Characteristics

Connectors Type

According to AISG Standard 2.0 (Data rate:9.6kB)


RF

7/16 DIN-Female

AISG

8-pin Female IEC60130-9


(Pin6:+24V, Pin3:RS485B, Pin5:RS485A, Pin7:DC
return; other pins: not connected)

Operating Voltage

+9 to +30

Operating Current

mA

150 20@+24V

Power Consume

Operation Mode (Only Node B0 pass DC/OOK)

DC/OOK Node B0

Dimensions, LxWxH (excluding connector and mounting


mm (in)
brackets)
Weight
kg (lb)

200x194x54.3(7.9x7.7x2.1)
4.0(8.8)

Mounting

Mast mounting: with clamp set

Enclosure Color

Light Grey

Enclosure Material

Aluminum

Operating Temperature

-40 to +65

Operating Humidity

95

EMC

ETS 300 342-3


RF

Lightning Protection

8kA, 8/20s
RS485A. RS485 B Different mould 3kA. Common
mould 5kA, DC and GND Different mould 3kA
IP66

AISG

Environmental Class
MTBF

hr

> 1,000,000

Note: Measurements taken at room temperature, unless otherwise stated.

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

98

Issued: Nov 11
Control: 3-0-1
2/2

Twin UMTS2100 Tower Mounted Amplifier


TA-W12FDA-02
Features

Two TMA units in one enclosure


Balanced LNA design and power failure bypass for high reliability
Light weight and compact design
Salt spray resistance, IP67
Built-in lightning protection and vented enclosure design
EMP protection with excellent MTBF
AISG 1.1 Compatible and can be updated to AISG 2.0 remotely.
Photo for reference

Product Description
The TA-W12FDA-02 is a UMTS2100MHz twin tower mounted amplifier for both main and diversity branch and fits with
cross-pole antennas. The unit is installed near the antenna at the tower top to improve receiver sensitivity of the base
station. The usage of TA-W12FDA-02 will result in an increase of successful call attempts, reduction of call drops,
maximized data transmission rate, improved call quality and extended handset talk time. Quality improvements will lead
to increased traffic volume and user satisfaction, hence increasing network revenue. It is recommended for use in new
network roll-outs to minimize base station count, or for upgrading of existing base stations to improve signal quality and
drop call performance.
The system comprises high quality band-pass filters, low noise amplifiers (LNA), bias tee, lightning protection and by-pass
circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault in the system.

Typical Application Block Diagram

ANT0

ANT1

The top of
the tower

DC GND

DC GND

Rx1 Fil

RET
7/8 RF Cable

Rx1 Fil

RxBypass

RCU

TA-W 12FDA02

RxBypass

RCU

Multi -cable
LNA

LNA

LNA
Supervision
and Alarm
Generation
Unit

Rx2 Fil

Node B

DC Power

LNA

Tx Fil

From CCU
or Node B

BT-R 1S 2

Rx2 Fil
7 /8 RF Cable

The root of
the tower

RS485A
RS485B

Tx Fil

Bias Tee
and Lightning
Protection

LNA

7 /8 RF Cable

Lightning
Protection

Node

Modem
To RCU

Node B1

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

99

Issued:Sep.2012
Control: 0-0-1
1/2

Twin UMTS2100 Tower Mounted Amplifier


TA-W12FDA-02
Technical Specifications
Electrical - Uplink
Frequency Range

MHz

Bandwidth

MHz

60

System Gain

dB

12

Noise Figure

dB

2.0 dB(Typical 1.7)

Gain Ripple

dB

0.5

Insertion Loss in By-pass Mode

dB

2.3

Output 3rd Order Intercept Point (OIP3)


Return Loss

1920-1980

25

dBm

Normal Operation
By-pass Mode

18

dB

16

Tx-Rejection

dB

75

Group Delay

ns

150

Impedance

50

Frequency Range

MHz

2110-2170

Bandwidth

MHz

60

Insertion Loss

dB

0.5

Return Loss

dB

18

Rx-rejection

dB

> 45

Average operating power, max.

200 (+53dBm)

Electrical Downlink

Power Handling Survival


Intermodulation in Rx band @2x43dBm
Impedance

500 (+57dBm)

dBm

-120

50

Power, Mechanical & Environmental


DC and Alarm port

DC and monitor signal only form Node B0 port

AISG Compatible

AISG1.1 (can be updated to AISG2.0 remotely)

Dimensions, LxWxH excluding connectors

mm(in)

Weight

kg(lb)

Mounting Kit
RF

20019455 (7.88x7.64x2.2)
3.0(6.6)
Pole mounting
7/16 DIN-Female
7/16 DIN-Female
8-pin Female IEC60130-9
(Pin1:+12V ,Pin3:RS485B, Pin5:RS485A,
Pin6:+24v,Pin7:DC return; other pins: not
connected)
Light Grey, NCS 1502-R

ANT
Node B

Connectors Type
AISG
Enclosure Color
Enclosure Material

Aluminum

Operating Temperature

Operating Humidity

EMC and Safety Approvals

-40 to +65
100
ETS 300 342-3

Lightning Protection

IEC 1312-1, 8/20 s pulse, 8kA

Weather Protection

DIN 400 50: IP67. ETS 300 019-1-4

MTBF

hr

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

100

> 500,000

Issued:Sep.2012
Control: 0-0-1
2/2

Twin 2100MHz Tower Mounted Amplifier


TA-W12FD
Features

Two TMA units in one enclosure


Balanced LNA design and power failure bypass for high reliability
Alarm management: DC current load simulation
Light weight and compact design
Salt spray resistance
IP66 with Gore Tex ventilation membrane
Built-in lightning protection and vented enclosure design
EMP protection with excellent MTBF

Product Description
The TA-W12FD is a WCDMA2100MHz twin tower mounted amplifier for both main and diversity branch and fits with
cross-pole antennas. The unit is installed near the antenna at the tower top to improve receiver sensitivity of the base
station. The usage of TA-W12FD will result in an increase of successful call attempts, reduction of call drops, maximized
data transmission rate, improved call quality and extended handset talk time. Quality improvements will lead to increased
traffic volume and user satisfaction, hence increasing network revenue. It is recommended for use in new network
roll-outs to minimize base station count, or for upgrading of existing base stations to improve signal quality and drop call
performance.
The system comprises high quality band-pass filters, low noise amplifiers (LNA), bias tee, lightning protection and bypass
circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault in the system.
Power is supplied via external bias tees that connect between the TA-W12FD and the PDM. Each PDM is constructed into
a 19 1U form factor, and can provide power for up to three units of TA-W12FD.

Typical Application Block Diagram


To Antenna

To Antenna

ANT1 Port

ANT0 Port

The top of
the tower
Rx1 Fil

LNA

Tx Fil
Rx2 Fil

LNA

LNA

LNA0 Alarm
Generation Unit
LNA1 Alarm
Generation Unit

RxBypass

ANT

Rx1 Fil

LNA

RxBypass

TA-W12FD

Tx Fil

7/8 RF Cable

7/8 RF Cable

Rx2 Fil

Bias Tee

Bias Tee

BTS0 Port

DC From
Node B

BTS1 Port

BT-M1

BT-M1

DC From
Node B
The root of
the tower

Bias Tee

Bias Tee

Node B
+12V

BTS

PDM

Alarm
To BTS

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

101

Issued: Nov11
Control: 3-1-1
1/2

Twin 2100MHz Tower Mounted Amplifier


TA-W12FD
Technical Specifications
Electrical - Uplink
Frequency Range

MHz

Bandwidth

MHz

60

dB

12 1

Noise Figure

dB

1.9 (typ. 1.5)

Pass Band Ripple

dB

1.0

Insertion Loss in By-pass Mode

dB

2.3(typ. 1.7)

dBm

25

System Gain

Output 3rd order Intercept Point


Return Loss

Normal Operation
Bypass Mode

ns

Group Delay per 5MHz Band

ns

Alarm Management

Major Alarm

18

dB

Group Delay
Minor Alarm

1920-1980

14
80
20
230 (Operation)

mA

330 (By-pass Mode)

Electrical Downlink
Frequency Range

MHz

Bandwidth

MHz

60

dB

0.5

Insertion Loss

2110-2170

dB

18

Absolute Maximum RF Input Power

dBm

52 (CW); 58.6 (Peak)

Inter-modulation Products in RX Band

Return Loss

dBm

-117 (2 TX carriers at +43dBm)

Group Delay

ns

25

Group Delay per 5MHz Band

ns

Power, Mechanical & Environmental


Operating Voltage
Operating Current per Port
Power Consume per Port
Dimensions, LxWxH (excluding connectors & mounting
brackets)
Weight

9 to +15

mA

11010 @+12V

1.5

mm(in)

192x196x54 (7.5x7.7x2.1)

kg(lb)

4 (8.8)
Wall mounting: with 4 screws

Mounting

Mast mounting: with clamp set

Connector Type

7/16 DIN-Female

Enclosure Color

Light Grey

Enclosure Material
Operating Temperature
Operating Humidity
EMC
Lightning Protection

Aluminum
C
%

-40 to +65
95
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s

hr

> 1,000,000

Environmental Class
MTBF

IP66
Note: Measurements taken at room temperature, unless otherwise stated.

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

102

Issued: Nov11
Control: 3-1-1
2/2

Twin LTE2.6G AISG2.0 Tower Mounted Amplifier


TA-Y12FDA-A
Features

Two TMA units in one enclosure.


Bypass mode ensures minimal disruption to uplink signal during power failure.
Light weight and compact design.
Built-in lightning protection.
Ventilated design using GORE-TEX membrane helps prevent moisture from
building up within enclosure.
AISG 2.0 Compatible.
Photo for reference

Product Description
TA-Y12FDA-A is a LTE2.6G twin tower mounted amplifier for both main and diversity branch of a cell sector. The unit is
installed near the antenna at the tower top to improve receive sensitivity of base station. The usage of TA-Y12FDA-A will
result in increase of successful call attempts, reduction of call drops, maximized data transmission rate, improved call
quality and extended handset talk time. RF quality improvements will lead to increased traffic volume and user
satisfaction, hence increasing network revenue. It is recommended for use in new network roll-outs to minimize base
station count, or for upgrading of existing base stations to improve signal quality and drop call performance.
TA-Y12FDA-A is made of high quality band-pass filters, low noise amplifier (LNA), bias tee, and lightning protection and
bypass circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault in the
system. An AISG port is located beneath the TMA for connection to other AISG compliant line devices.

Typical Application Block Diagram

ANT0

ANT1

The top of
the tower

DC GND

DC GND

Rx1
Filter

RET
7/8 RF Cable

Rx1
Filter

RxBypass

TAY12FDA-A

RxBypass

RCU

RCU

Multi-cable
LNA

LNA

7/8 RF Cable

LNA
LNA
Tx
Filter

Tx
Filter

Supervision
and
and
Alarm
Alarm
Generation

Rx2
Filter

NodeB 0

RS485B

AISG
DC

DC
RS485A

Bias Tee
and Lightning
Protection

Rx2
Filter

Unit
Unit

Lightning
Protection

AISG
DC

7/8 RF Cable
Bias Tee
and Lightning
Protection

From CCU
or Node B
The root of
the tower

Node B

Modem
To RCU

BTR1S2

NodeB 1

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

103

Issued: Nov 11
Control: 2-0-1
1/2

Twin LTE2.6G AISG2.0 Tower Mounted Amplifier


TA-Y12FDA-A
Technical Specifications
Electrical - Uplink
Frequency Range

MHz

2500-2570

Bandwidth

MHz

70
12 1

System Gain

dB

Noise Figure

Room temperature

dB

-40 oC to +65 oC

dB

Insertion Loss in By-pass Mode


Output 3rd Order Intercept Point (OIP3)

2.2

dB
dBm

Normal Operation

Return Loss

1.9 (typ. 1.6)


2.1
24
18

dB

Bypass Mode

14

Alarm Management in AISG Mode

Compatible with AISG 2.0

Electrical - Downlink
Frequency Range
Bandwidth

MHz
MHz

Insertion Loss

2620-2690
70
0.5

dB
dB

18

Absolute Maximum RF Input Power

dBm

Inter-modulation Products in RX Band

dBm

50 (Avg.); 58.6 (Peak)


-110 (2 TX carriers at +43dBm)

According to AISG Standard 2.0 (Data rate:9.6kB)


+10 to +30

mA

140 10@+24V

3.5

Return Loss

Power, Mechanical & Environmental


Modem Characteristics
Operating Voltage
Operating Current
Power Consume
Alarm management
Dimensions, LxWxH (Including connectors
mounting kits)
Weight(Including connectors and mounting kits)

AISG
and

mm (in)

272x194x83.8(10.6x7.7x3.3)

kg (lb)

4 (8.8)
Wall mounting: with 4 screws

Mounting, max. 8mm diameter

Mast mounting: with clamp set

RF
Connectors Type

7/16 DIN-Female
8-pin Female IEC60130-9
(Pin6:+24V, Pin3:RS485B, Pin5:RS485A, Pin7:DC
return; other pins: not connected)
Light Grey

AISG

Enclosure Color
Enclosure Material
Operating Temperature Range
Operating Humidity
EMC
RF
Lightning Protection
AISG
Environmental Class
MTBF

Aluminum
-40 to +65
95
ETS 300 342-3
8kA, 8/20s
RS485A. RS485B different mould 3kA. Common
mould 5kA, DC and GND different mould 3kA
IP66
hr
> 1,000,000
Note: Measurements taken at room temperature, unless otherwise stated.
o

C
%

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

104

Issued: Nov 11
Control: 2-0-1
2/2

Dual Band Tower Mounted Amplifier


TA-C12G12FDA-A
Features

Dual band 800/900 full duplex TMA


Alarm for LNA 800MHz will be reported through AISG protocol
Alarm for LNA 900MHz will be reported through current window(CWA) or AISG
protocol
For deploying 800MHz on top of existing 900MHz antenna line system without
the need to rely on additional jumpers or feeders.
Salt spray resistance, IP67
Built-in lightning protection and vented enclosure design
EMP protection with excellent MTBF
AISG 2.0 Compatible

Product Description
The TA-C12G12FDA-A is a dual band tower mounted amplifier aims to provide tower top LNA functionalities for both
800MHz and 900MHz for antenna line systems equipped with one pair of feeders on both antenna and BTS ports. The unit
is installed near the antenna at the tower top to improve receiver sensitivity of the base station. The usage of
TA-C12G12FDA-A will result in an increase of successful call attempts, reduction of call drops, maximized data
transmission rate, improved call quality and extended handset talk time. Quality improvements will lead to increased
traffic volume and user satisfaction, hence increasing network revenue. It is recommended for use in new network
roll-outs to minimize base station count, or for upgrading of existing base stations to improve signal quality and drop call
performance.
The system comprises high quality band-pass filters, low noise amplifiers (LNA), bias tee, and lightning protection and
by-pass circuitries. The LNA bypass circuitry is activated when the DC supply is switched off or when there is a fault in the
system.

Block Diagram

ANT 1

ANT0

DC GND

DC GND

900 Tx
filter

800 Tx
filter
LNA

900 Rx
filter

800 Rx
filter

800 Rx
filter
900
LNA
Monitor
Unit
(CWA)
(AISG)

900 Rx
filter

800 Tx
filter

LNA

LNA

900 Tx
filter

LNA

800
LNA
Monitor
Unit
(AISG)
900 Rx
filter

800 Rx
filter

Smart Bias Tee


Lightning
Protection

Smart Bias Tee

Modem
BTS 0

900 Rx
filter

800 Rx
filter

Lightning
Protection

Modem
To RCU

To RCU

BTS 1

AISG 900 AISG 800

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

105

Issued: Nov.12
Control: 1-0-0
1/3

Dual Band Tower Mounted Amplifier


TA-C12G12FDA-A
Technical Specifications
Electrical Uplink
Frequency Range(900MHz band)
Frequency Range(800MHz band) for High frequency HW
variant
System Gain

MHz

890-915

MHz

842-862

dB

121.0

Noise Figure

dB

typ. 1.5 / max. 1.8

Insertion Loss in By-pass Mode

dB

typ. 3.0/max. 3.5

Input 1-dB compression point

dBm

Input 3rd order intercept point

dBm

14

Return Loss

Normal Operation

18

dB

By-pass Mode

Maximum input power for RX input

14

dBm

MHz

935-960

MHz

801-821

dB

max. 0.7

Electrical Downlink
Frequency Range(900MHz band)
Frequency Range(800MHz band) for High frequency HW
variant
Insertion Loss

dB

18

Absolute Maximum RF Input Power @800MHz

dBm

48(CW); 57(Peak)

Absolute Maximum RF Input Power @900MHz

dBm

49(CW); 58(Peak)

Return Loss

DC and Alarm Characteristics for 800MHz


Alarm management

Per AISG2.0

Modem Characteristics

According to AISG Standard 2.0

Operating Voltage
Operating current consumption in CWA mode

V
W

+10 to +30
< 2(<80@ +24V)

CWA or AISG2.0 compliance


+10.5 to +13.5
<150(maximum in voltage range +10.5V to
13.5V)
22020
+10 to +30
< 2(<80@ +24V)

DC and Alarm Characteristics for 900MHz


Alarm management
Nominal voltage range(in CWA mode)
Operating current in CWA mode

mA

Current alarm window


Nominal voltage range(in AISG mode)
Operating current consumption in CWA mode

mA
V
W

Mechanical & Environmental Characteristics


Dimensions, LxWxH (excluding the connectors and the
mounting brackets)
Weight

mm

< 230 x210 x 140

kg

Mounting

<12
Pole mounting: with clamp set
Wall mounting: with 4 screws
Light Grey

Enclosure Color

Enclosure Material

Aluminum

Operating Temperature

Operating Humidity

100

ETS 300 342-3

EMC
RF
Connectors Type

Lightning Protection

AISG
ANT port

-40 to +55

7/16 DIN-Female

8-pin female, IEC 60130-9


(pin3: RS485B, pin5: RS485A, pin6: +24V, pin7:
DC return, other pins: not connected)

BTS port

Environmental Class
MTBF

IP67

hr

> 1,000,000

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

106

DC Ground
10kA, 8/20s

Issued: Nov.12
Control: 1-0-0
2/3

Dual Band Tower Mounted Amplifier


TA-C12G12FDA-A
Application diagram

X
X
X
X
X
X

AISG
for
RET

TMA management
Ant 0

Ant 1

TMA
800 / 900

LNA
900
800/900
Main path

Diplexer
800/900

Diplexer
800/900

AISG
800

BTS 0

AISG

CWA/AISG

LNA
800

800/900
div path

800/900
Main path

TRDU
800

800/900
div path

BTS1

AISG 900

CWA
ANC

LNA
900

LNA
800

(DC nom. = 12 VDC)


(DC nom. = 24 VDC)

AISG
(DC nom. = 24 VDC)

MC-TRX
900

Multi RAT BTS

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

107

Issued: Nov.12
Control: 1-0-0
3/3

Wide-band OOK Bias Tee


BT R1, BT-R2
Features and Product Description

Wide-band design covers 698-2700MHz range

Injects DC voltage and OOK signal (2.176 MHz) to ALDs

Complies with AISG 2.0/3GPP

Extremely low insertion loss and VSWR

Provides lightning protection for BTS

Suitable for operating in high or low temperature, humidity and other bad
environment

BT-R2 photo shown for reference

Technical Specifications
Electrical

BT-R1

Frequency Range
Insertion Loss
VSWR
Inter-modulation Products
Power Handling
Current Capacitance
Operational Voltage
Impedance

MHz
dB

BT-R2

dBc
W
A
V

698-2700
0.2
1.2
-153 @2x43dBm
120
2.3
9-30
50

mm(in)

1195745(4.72.21.8)

Mechanical
Dimensions, LxWxH (including connectors)
Weight
Connectors

kg(lb)
BTS/Node B Port
ANT Port

0.5 (1.1)
7/16 Male
7/16 Female

Operational Humidity
Temperature Range
Environmental Class
Lightning Protection
EMC

7/16 Female
7/16 Male

<95
-40 to +60
IP66 (Indoor or Outdoor)
8kA, 8/20s
ETS 300 342-3

Outline Drawing
BT-R2 outline
drawing reference

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

108

Issued: Sep10
Control: 3-0-0
1/1

Wide-band Smart Bias Tee (AISG 2.0)


BTR1S2, BTR2S2
Features and Product Description

Designed to cover 698-2700MHz

Provides DC voltage as well as remote control signals via RF feeder cable to TMA
or Antenna Line Devices (ALD)

Complies with AISG2.0 standard

Extremely low insertion loss and VSWR

Provides lightning protection for BTS/Node B

BT-R1S2 is commonly installed close to BTS/Node B and BT-R2S2 is installed on


the tower close to VET antenna when no TMA is in use

BT-R2S2 photo shown for reference

Technical Specifications
Electrical

BT-R1S2

Frequency Range
Insertion Loss
VSWR
Modem Carrier Frequency
Inter-modulation Products
Power Handling
Current Capacity
Power Consume
Operational Voltage

MHz
dB

mm (in)

1197346(4.72.91.8)

kg (lb)

0.45 (0.99)
7/16 DIN Male
7/16 DIN Female
7/16 DIN Female
7/16 DIN Male
8-pin Male Connector
8-pin Female Connector
5 - 95
-40 to +65
IP66 (Indoor or Outdoor)
8kA, 8/20s
ETS 300 342-3

MHz
dBc
W
A
W
V

Model
Impedance

BT-R2S2

698-2700
0.2
1.2
2.176
-153 @2x43dBm
120
2.3
0.8
10-30
+24V (AISG port in,ANT
+24V (BTS/Node B port
port out)
in, AISG port out)
50

Mechanical
Dimensions, LxWxH (including connectors)
Weight
Connectors
Operational Humidity
Temperature Range
Environmental Class
Lightning Protection
EMC

BTS/Node B Port
ANT Port
DC/AISG Port
%
o
C

Outline Drawing
BT-R2S2 outline
drawing reference

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

109

Issued:Sep10
Control:3-0-1
1/1

Power Distribution Management Unit


PDM-001B/003B
Features and Product Description

Provide constant +12VDC power via Bias Tee and alarm handling for up
to 6 TMAs

Can be powered by +24VDC or -48VDC alternatively

Two variants available: PDM-001B and PDM-003B

TMA operation status can be monitored by the PDM LED indicator

Light weight and compact design

Standard 1U 19 form factor

PDM-003B

Technical Specifications
Input power
VDC

-48 or +24

20

Output Voltage

VDC

+12

Maximum Output Current per Output

mA

Supply Voltage
Input Voltage Fluctuation

Output Power
350

Number of Outputs

2 or 6

Power, Mechanical & Environmental


Dimensions, HxWxD

mm (in)

Weight

45x482x152 (1.8x18.9x6.0)

kg (lb)

2.5 (5.5)
Light Grey

Enclosure Color

Aluminum

Enclosure Material
Operating Temperature

-10 to +50

Operating Humidity

<95

EMC

ETS 300 342-3


Indoor Application

Environmental Class

Note: Measurements taken at room temperature

PDM Connectors
All connectors are polarized to ensure correct cable is used and fitted properly. The description of each pin is shown in Table
1. Pin number is labelled from left to right whilst looking into the front panel.

Unit C
VoutA

VoutB

ALARM1 ALARM2

--

POWER
+24V GND -48V
VIN

ATT trimmer
+12V Output Power LED

+12V Power output

Power in LED
Normally Open
Normally Closed

PDM-003B front-panel

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

110

Issued: May09
Control: 3-0-0
1/2

Power Distribution Management Unit


PDM-001B/003B
PIN

Connectors

4
-48VDC

VIN (input to PDM)

+24VDC

Ground

Ground

+12VDC Power Outputs

Ground

+12V Power Output

Ground

ALARM1

Normally Open(when used will not used ALARM2)

ALARM2

Normally Closed(when used will not used ALARM1)

Table 1: Definitions of connectors on the PDM front-panel


Connector

Descriptions
Four-pin power input connector. The PDM is fed with -48VDC or +24VDC via this port.

VIN

This three-pin connector provides DC power supply to the TMA. It is connected to the +12VDC
power input connector (SMA-J) of the Bias Tee

+12VDC Power Output

This Two-pin connector connects to the BTS alarm terminal for alarm reporting purposes.
When connect to BTS Normally open, connect this PIN, Alarm is sent to the BTS using relay*.
This occurs when LNA is faulty or when PDM output voltage is outside the range of 11.75V to
12.25V. Under this condition, the auto bypass switch will be activated to ensure that the UL
signals are still received by the BTS.

ALARM1

This Two-pin connector connects to the BTS alarm terminal for alarm reporting purposes.
When connect to BTS Normally Closed, connect this PIN, Alarm is sent to the BTS using relay*.
This occurs when LNA is faulty or when PDM output voltage is outside the range of 11.75V to
12.25V. Under this condition, the auto bypass switch will be activated to ensure that the UL
signals are still received by the BTS.

ALARM2

Table 2: Descriptions of connectors on the PDM front-panel

Outline Drawing
C
t
i
n
U

B
t
i
n
U

A
t
i
n
U

R
E
W
O
P

2
M
R
A
L
A

1
M
R
A
L
A

B
t
u
o
V

A
t
u
o
V

R
E
W
O
P

2
M
R
A
L
A

1
M
R
A
L
A

B
t
u
o
V

A
t
u
o
V

R
E
W
O
P

2
M
R
A
L
A

1
M
R
A
L
A

B
t
u
o
V

A
t
u
o
V

+ 24V

GND

-48V

VIN

Note: The figure above shows front panel of the PDM-003B. The connections within each unit are the same. Each unit has one
LED indicator with one LED indicator for every output. PDM-001B just has one unit (Unit A).

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

111

Issued: May09
Control: 3-0-0
2/2

Indoor Diplexer
CM-BK2-IN1B
Features and Product Description
z
z
z
z
z

Compact and cost effective solutions for combining two different input frequency
bands into one common output.
Combines GSM/CDMA and DCS/WCDMA bands.
Low loss maximizes system performance.
High isolation minimizes interference.
Fast and easy installation.

Technical Specification
Electrical
Frequency Range
Bandwidth
Isolation between Bands
Input Power
Insertion Loss
Return Loss
3rd Order Intermodulation
Impedance

MHz
MHz
dB
W
dB
dB
dBc

800 960(Port 2)
160
80@1710MHz-2170MHz

1710 2170(Port 3)
460
80@800MHz-960MHz

100
0.3
20
-140 @2x43dBm
50

Mechanical
Dimension (LxWxH)
Weight
Material and Color
Connector Type
Operational Temperature
Operational Humidity
Environmental Class

mm (in)
kg (lb)

198x88x40 (7.8x3.5x1.6)
2.5 (5.5)
Aluminum, Grey
N-Female
-25 to 65
< 95
Indoor

C
%

Block Diagram

Port 1
COM

Port 2
800-960

Port 3
1710-2170

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

112

st

Issued: 1 Dec10
Control: 3-0-0
1/1

Indoor Diplexer
CM-BDW2-IN1
Features and Product Description

Compact and cost effective solutions for combining two different input frequency
bands into one common output.
Combines CDMA800, GSM, UMTS and 3G bands.
High power handling and low loss maximizes system performance.
High isolation minimizes interference.
Use for integrating new services into existing CDMA800/GSM900 in-building
systems.

Technical Specification
Electrical
Frequency Range
Input Power
Insertion Loss

MHz
W
800 960 MHz
1710 1880 MHz
1920 2170 MHz

Return Loss
Isolation between Bands
800 960 MHz
Pass Band Ripple
1710 1880 MHz
1920 2170 MHz
Impedance

800-960, 1710-1880

1920-2170
200
0.4
0.6
0.6
18
60
0.3
0.4
0.4
50

dB
dB
dB
dB

Mechanical
Dimension, LxWxH
Weight
Material and Color
Connector Type
Operational Temperature
Operational Humidity
Environmental Class

mm (in)
kg (lb)

198x166x48 (7.8x6.5x1.9)
1.8 (4.0)
Aluminum, Painted Grey
Type N-Female
-35 to +70
< 95
Indoor

C
%

Block Diagram
Port 3

Port 1
806-960,
1710-1880

Port 2
1920-2170

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

113

Issued:12Jan10
Control: 3-0-0
1/1

Indoor Triplexer
CM-BDW3-IN1B
Features and Product Description

Compact and cost effective combining of CDMA800, GSM900, GSM1800 and UMTS
signals.
100W power handling capability.
Low loss maximizes system performance.
High isolation minimizes interference.
Provide solutions for combining three different input frequency bands into one
common output.
Use for integrating new UMTS services into existing 2G in-building antenna
distribution systems.

Technical Specification
Electrical
Frequency Range
Input Power
Insertion Loss
Return Loss
Isolation
between Bands

MHz
W
dB
dB
2G / 2G
DCS / 3G
GSM / 3G

800 960
0.4

dB

Pass Band Ripple


Impedance

dB

0.35

1710 1880
100
0.6
18
80
65
80
0.4
50

1920 2170
0.6

0.4

Mechanical
Dimension (L x W x H, excluding
connector)
Weight
Material and Color
Connector Type
Operational Temperature
Operational Humidity
Environmental Class

mm

198 x 166 x 40

kg

3.5
Aluminum, Grey
Type N-Female
-40 to +85
< 95
Indoor

C
%

166

Ordering Outline drawing

198

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

114

40

Issued: 19Feb09
Control: 3-1-0
1/1

Indoor Diplexer
CM-DW2-IN1
Features and Product Description

Compact and cost effective solutions for combining GSM1800 and UMTS2100
bands.
Low loss maximizes system performance.
High isolation minimizes interference.
Fast and easy installation.

Technical Specification
Electrical
Frequency Range
Insertion Loss
Isolation between Bands
Input Average Power
Return Loss
Intermodulation@2x43dBm in Tx
Impedance

MHz
dB
dB
W
dB

1710 - 1880

1920 - 2170

0.6
> 60
100
20
-140
50

mm (in)

142x112x34 (5.6x4.4x1.3)

kg (lb)

2.0 (4.4)
Aluminum, Grey
N-Female
-40 to +65
< 95
Indoor

Mechanical
Dimension, LxWxH (excluding
connectors)
Weight
Material and Color
Connector Type
Operational Temperature
Operational Humidity
Environmental Class

C
%

Block Diagram

Port 3

Port 1
1710-1880

Port 2
1920-2170

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

115

Issued: 12Jan10
Control: 3-0-1
1/1

Diplexer
CM-KY2-IN1
Features and Product Description

Compact and cost effective solutions for combining GSM1800/UMTS2100 and LTE
frequency bands.
Low loss maximizes system performance.
High isolation minimizes interference.
Fast and easy installation.

Technical Specification
Electrical
Frequency Range
Insertion Loss
Isolation between Bands
Input Power
Return Loss
Intermodulation@2x43dBm in Tx
Impedance

MHz
dB
dB
W
dB

1710-2170

2400-2700

0.2
> 50
250
20
-140
50

mm (in)

169x109x42.5 (6.7x4.3x1.7)

kg (lb)

2.0 (4.4)
Aluminum, Grey
N-Female
-40 to +65
< 95
Indoor

Mechanical
Dimension (LxWxH, excluding
connectors)
Weight
Material and Color
Connector Type
Operational Temperature Range
Operational Humidity
Environmental Class

C
%

Outline Drawing
42.5

4- 4.5

57

99

109

DCS/WCDMA

26

54.5

COM

WLAN/LTE

16.5
34.5

159
169

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

116

16.5

Issued: Aug09
Control: 3-0-0
1/1

Indoor Diplexer
CM-ML2-IN2
Features and Product Description

Compact and cost effective solutions for combining two different input frequency
bands into one common output.
Designed for in-house multi-band distribution networks.
Low loss- maximizes system performance.
High isolation- minimizes interference.
DC by-pass between low frequency band port and COM port.

Technical Specification
Electrical
Frequency Range
Insertion Loss
Isolation between Bands
Input Power
Return Loss
PIM
Impedance

MHz
dB
dB
W
dB
dBc

50 - 2200

2400 - 2500
0.4
> 50
200
20
-140 @2x43dBm
50

Mechanical
Dimension (LxWxH)
Weight
Material and Color
Connector Type
Operational Temperature
Operational Humidity
Environmental Class

mm (in)
kg (lb)

153.5x86x37.4 (6.0x3.4x1.5)
2.0 (4.4)
Aluminum, Grey
N-Female
-20 to +65
< 95
Indoor

C
%

Block Diagram

DC/AISG Bypass

Port 3

Port 1
50-2200

Port 2
2400-2500

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

117

Issued: 29Dec09
Control: 3-0-0
1/1

Wideband Diplexer
CM-BK2-ODxx, CM-BK2D-ODxx (x= 1, 2, 3 or 4, Preconfigured DC-pass)

Features and Product Description

Wide-band design to enable feeder sharing between systems in the


806-960MHz range and the 1710-2170MHz range
Fast and easy installation
High power handling and low loss maximizes system performance
500W maximum output power rating
High isolation minimizes interference
Build with optional DC bypass, to be used with Tower Mounted Amplifiers and
AISG devices
Available as a single unit or double unit

CM-BK2D-ODxC shown

Technical Specifications
Electrical
Pass Band Frequency Range
Insertion Loss

MHz
dB

Isolation between Bands

dB

Return Loss
Maximum input power pre port
Maximum output power at Common Port
Intermodulation Products
Impedance

dB
W
W
dBc

806-960
0.2

250

1710-2170
0.3
60 @806-960MHz
80 @1710-2170MHz
21
250
500
-155 @2x43dBm
50

Mechanical
Dimensions, LxWxH
(including mounting brackets)
Weight
(including mounting brackets)
Colors
Housing
RF Connectors
Mounting Kit

Single unit
Double unit
Single unit
Double unit

309x105x89 (12.2x4.1x3.5)
303x133x124 (11.9x5.2x4.9)
2.5 (5.5)
4.0 (8.8)
Light Grey
Aluminum
7/16 DIN-Female
Pole (clamps included for 35-125mm) or wall mounted

mm (in)
kg (lb)

Environmental Characteristics
o

Operating Temperature Range


Operational Humidity
Environment Class
EMC
Lightning Protection
MTBF

C
%

-40 to +65
<95
IP66 (Indoor or Outdoor)
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s
> 1,000,000

hr

Ordering Information and Block Diagram


Single unit Model Number
CM-BK2-OD1C
CM-BK2-OD2C
CM-BK2-OD3C
CM-BK2-OD4C

Double unit Model Number


CM-BK2D-OD1C
CM-BK2D-OD2C
CM-BK2D-OD3C
CM-BK2D-OD4C

DC Bypass Optional
No DC Path
DC Path in Low Frequency Band
DC Path in High Frequency Band
Full DC Path

Port 1
806-960

DC/AISG Bypass

DC/AISG Bypass

Port 3

Port 2
1710-2170

Example: View of single unit CM-BK2-OD4C


Information contained in this document is subject to confirmation at time of ordering.
http://www.comba-telecom.com

118

Issued: Jun10
Control: 3-5-0
1/1

Diplexer
CM-DW2-ODxx, CM-DW2D-ODxx (x= 1, 2, 3 or 4, Preconfigured DC-pass)

Features and Product Description

Enables feeder sharing between DCS1800 and UMTS system


Compact design suitable for indoor and outdoor application
Fast and easy installation
High power handling and low loss maximizes system performance
500W maximum output power rating
High isolation minimizes interference
Build with optional DC bypass, to be used in applications with or without Tower
Mounted Amplifiers installed
Available as a single unit or double unit

CM-DW2D-ODxC shown

Technical Specifications
Electrical
Pass Band Frequency Range
Insertion Loss
Isolation between Bands
Return Loss
Maximum input power pre port
Maximum output power at Common Port
Intermodulation Products
Impedance

MHz
dB
dB
dB
W
W
dBc

1710-1880
0.3

1920-2170
0.3
50
20

250

250
500
-155 @2x43dBm
50

Mechanical
Dimensions, LxWxH
(including mounting brackets)
Weight
(including mounting brackets)
Colors
Housing
Connector Type
Mount Kit

Single Unit
Double Unit
Single Unit
Double Unit

mm (in)
mm (in)
kg (lb)
kg (lb)

332x146x86 (13.1x5.7x3.4)
303x173x106 (11.9x6.8x4.2)
3.5 (7.7)
6.0 (13.2)
Light Grey
Aluminum
7/16 DIN-Female
Pole (clamps included for 35-125mm Pole) or Wall mount

Environmental Characteristics
o

Operating Temperature Range


Operational Humidity
Environmental Class
EMC
Lightning Protection
MTBF

C
%

-40 to +65
<95
IP66 (Indoor or Outdoor)
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s
> 1,000,000

hr

Ordering Information and Block Diagram


Single unit Model Number
CM-DW2-OD1C
CM-DW2-OD2C
CM-DW2-OD3C
CM-DW2-OD4C

Double unit Model Number


CM-DW2D-OD1C
CM-DW2D-OD2C
CM-DW2D-OD3C
CM-DW2D-OD4C

DC Bypass Optional
No DC Path
DC Path in Low Frequency Band
DC Path in High Frequency Band
Full DC Path

Port 1
1710-1880

DC/AISG Bypass

DC/AISG Bypass

Port 3

Port 2
1920-2170

Example: View of single unit CM-DW2-OD4C


Information contained in this document is subject to confirmation at time of ordering.
http://www.comba-telecom.com

119

Issued: Jun10
Control: 3-5-0
1/1

Triple-band Combiner
CM-BDW3-ODxx, CM-BDW3D-ODxx (x= 1, 2 or 6, Preconfigured DC-pass)

Features and Product Description

Designed for feeder sharing and co-location purpose


High power handling and low loss maximizes system performance
750W maximum output power rating
High isolation minimizes interference
Build with optional DC (AISG signals) bypass
Available as a single unit or double unit
CM-BDW3D-ODxC shown

Technical Specifications
Electrical
Pass Band Frequency Range
Insertion Loss

MHz
dB

Isolation between Bands

dB

Return Loss
Maximum input power pre port
Maximum output power at Common Port
Intermodulation Products
Impedance

dB
W
W
dBc

806-960
0.2

250

1710-1880
1920-2170
0.3
0.3
50 (806-960/1710-1880MHz)
50 (806-960/1920-2170MHz)
50 (1710-1880/1920-2170MHz)
20
250
250
750
-155 @2x43dBm
50

Mechanical
Dimensions, LxWxH
(including mounting brackets)
Weight
(including mounting brackets)
Colors
Housing
RF Connectors
Mount Kit

Single Unit
Double Unit
Single Unit
Double Unit

Environmental Characteristics
Operating Temperature Range
Operational Humidity
Environment Class
EMC
Lightning Protection
MTBF

mm (in)
mm (in)
kg (lb)
kg (lb)

326x185x87 (12.8x7.3x3.4)
316x202x112 (12.4x8.0x4.4)
4 (8.8)
7 (15.4)
Light grey
Aluminum
7/16 DIN-Female
Pole (clamps included for 35-125mm Pole) or Wall mount

C
%

-40 to +65
<95
IP66 (Indoor or Outdoor)
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s
> 1,000,000

hr

Ordering Information and Block Diagram


Single unit Model Number
CM-BDW3-OD1C
CM-BDW3-OD2C
CM-BDW3-OD3C
CM-BDW3-OD4C
CM-BDW3-OD5C
CM-BDW3-OD6C

Double unit Model Number


CM-BDW3D-OD1C
CM-BDW3D-OD2C
CM-BDW3D-OD3C
CM-BDW3D-OD4C
CM-BDW3D-OD5C
CM-BDW3D-OD6C

DC Bypass Optional
No DC Path
DC Path in Low Frequency Band
DC Path in Mid Frequency Band
DC Path in High Frequency Band
DC Path in Mid and High Frequency Band
Full DC Path

Port 1
806-960

DC Bypass

DC Bypass

DC Bypass

Port 4

Port 2
1710-1880

Port 3
1920-2170

Example: View of Single unit CM-BDW3-OD6C


Information contained in this document is subject to confirmation at time of ordering.
http://www.comba-telecom.com

120

Issued: Jun10
Control: 3-6-0
1/1

Wideband Diplexer
CM-KY2-OD4B
Features and Product Description

Wide-band design enables feeder sharing between systems in the


1710-2170MHz range and the 2300-2700MHz range.
Long connectors allow ease of waterproofing.
High power handling and low loss maximizes system performance.
500W maximum output power rating
High isolation minimizes interference.
Built with full band DC bypass, to be used with Tower Mounted Amplifiers and
AISG compliant devices.

Technical Specifications
Electrical
Pass Band Frequency Range
Insertion Loss
Isolation between Bands
Return Loss
Power Handling
Intermodulation Products
Impedance

MHz
dB
dB
dB
W
dBc

1710-2170
0.3

2300-2700
0.3

70
20
300
-155 @2 x 43dBm
50

Mechanical
Dimension (LxWxH including mounting
brackets)
Weight
Colors
Housing
RF Connectors
Mounting Kit

mm (in)

275x121x90(10.8x4.8x3.5)

kg (lb)

2.3(5.1)
Light grey
Aluminum
DIN 7/16 female
Pole (clamps included for 35-125mm) or wall mounted

Environmental Characteristics
o

Operating Temperature Range


Operational Humidity
Environment Class
EMC
Lightning Protection
MTBF

C
%

-40 to +65
<95
IP67
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s
> 1,000,000

hr

Block Diagram

Port 1
1710-2170

DC/AISG Bypass

DC/AISG Bypass

Port 3

Port 2
2300-2700

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

121

Issued: Nov.12
Control: 2-0-0
1/1

Triple-band Combiner
CM-BKY3-OD6

Features and Product Description

Designed for feeder sharing and co-location purpose


High power handling and low loss maximizes system performance
750W maximum output power rating
High isolation minimizes interference
Build with optional DC (AISG signals) bypass
Available as a single unit or double unit

Technical Specifications
Electrical
Pass Band Frequency Range
Insertion Loss

MHz
dB

Isolation between Bands

dB

Return Loss
Maximum input power per port
Maximum output power at common port
Intermodulation Products
Impedance

dB
W
W
dBc

806-960

1710-2170
2300-2690
0.3
80 (806-960/1710-2170MHz)
80 (806-960/2300-2690MHz)
70 (1710-2170/2300-2690MHz)
20
250
250
750
-155 @2x43dBm
50

250

Mechanical
Dimensions, LxWxH
(excluding connectors and mounting brackets)
Weight
(including mounting brackets)
Colors
Housing
RF Connectors
Mount Kit

Environmental Characteristics
Operating Temperature Range
Operational Humidity
Environment Class
EMC
Lightning Protection
MTBF

mm (in)

14215657(5.596.142.24)

kg (lb)

2.5(5.51)
Light grey
Aluminum
7/16 DIN-Female
Pole (clamps included for 35-125mm Pole) or Wall mount

C
%

-40 to +65
<95
IP66
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s
> 1,000,000

hr

Ordering Information and Block Diagram

Port 1
806-960

DC Bypass

DC Bypass

DC Bypass

Port 4

Port 2
1710-2170

Port 3
2300-2690

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

122

Issued: June10
Control: 3-0-0
1/1

Quad-band Combiner
CM-BDWY4-OD8

Features and Product Description

Designed for feeder sharing and co-location purpose


High power handling and low loss maximizes system performance
500W maximum output power rating
High isolation minimizes interference
Built with full band DC bypass, to be used with Tower Mounted Amplifiers and AISG
compliant devices.
Available as a single unit or double unit

Technical Specifications
Electrical
Pass Band Frequency Range
Insertion Loss
Isolation between Bands
Return Loss
Maximum input power per port
Intermodulation Products
Impedance

MHz
dB
dB
dB
W
dBc

806-960

1710-1880

1920-2170

2500-2690

0.3
50
20
250

250
250
-155 @2x43dBm
50

250

Mechanical
Dimensions, LxWxH
(excluding connectors and mounting brackets)
Weight(approx.)
Colors
Housing
RF Connectors

Environmental Characteristics
Operating Temperature Range
Operational Humidity
Environment Class
EMC
Lightning Protection
MTBF

mm (in)

239x210x59.5(9.5x8.3x2.4)

kg (lb)

4.2(9.2)
Light grey
Aluminum
7/16 DIN-Female

C
%

-40 to +65
<95

hr

IP66(Indoor or Outdoor)
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s
> 1,000,000

Block Diagram

Port 1
806-960

Port2
1710-1880

Port 3
1920-2170

DC Bypass

DC Bypass

DC Bypass

DC Bypass

Port 5

Port 4
2500-2690

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

123

Issued: Feb11
Control: 2-0-0
1/1

Wideband Diplexer
CM-MY2-OD4

Features and Product Description

Wide-band design to enable feeder sharing between systems in the


806-960MHz&1710-2170MHz range and the 2300-2700MHz range
Fast and easy installation
500W maximum output power rating
High isolation minimizes interference
Build with optional DC bypass, to be used with Tower Mounted Amplifiers and
AISG devices
Available as a single unit or double unit

Photo for reference

Technical Specifications
Electrical
Pass Band Frequency Range
Insertion Loss
Isolation between Bands
Return Loss
Maximum input power per port
Maximum output power at common port
Intermodulation Products
Impedance

MHz
dB
dB
dB
W
W
dBc

806-960/1710-2170

2300-2700
0.3
70
20

250

250
500
-155 @2x43dBm
50

Mechanical
Dimensions, LxWxH
(including mounting brackets)
Weight
(including mounting brackets)
Colors
Housing
RF Connectors
Mounting Kit

mm (in)

14215657(5.596.142.24)

kg (lb)

2.4(5.29)
Light Grey
Aluminum
7/16 DIN-Female
Pole (clamps included for 35-125mm) or wall mounted

Environmental Characteristics
o

Operating Temperature Range


Operational Humidity
Environment Class
EMC
Lightning Protection
MTBF

C
%

-40 to +65
<95
IP66
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s
> 1,000,000

hr

Ordering Information and Block Diagram

DC/AISG Bypass

DC/AISG Bypass

Port 3

Port 2
2300-2700

Port 1
806-960/
1710-2170

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

124

Issued: Mar.12
Control: 2-0-0
1/1

Dual-Band Combiner
CM-PK2-OD4
Features and Product Description

Wide-band design enables feeder sharing between systems in the


1850-1910/1930-1990MHz range and the 1710-1755/2110-2155MHz range.
Long connectors allow ease of waterproofing.
High power handling and low loss maximizes system performance.
High isolation minimizes interference.
Built with full band DC bypass, to be used with Tower Mounted Amplifiers and
AISG compliant devices.

Photo for reference

Technical Specifications
Electrical
Pass Band Frequency Range
Insertion Loss
Isolation between Bands
Return Loss
Power Handling Continuous
Power Handling Continuous at Common Port
Intermodulation Products
Impedance

MHz
dB
dB
dB
W
W
dBc

1850-1910/1930-1990
0.3

1710-1755/2110-2155
0.2
50
20

250

250
500 average
-155 @2 x 43dBm
50

Mechanical
Dimension (LxWxH including mounting
brackets)
Weight
Colors
Housing
RF Connectors
Mounting Kit

mm (in)

302x143x79(11.9x5.6x3.1)

kg (lb)

2.1(4.6)
Light grey
Aluminum
DIN 7/16 female
Pole (clamps included for 35-125mm) or wall mounted

Environmental Characteristics
o

Operating Temperature Range


Operational Humidity
Environment Class
EMC
Lightning Protection
MTBF

C
%

-40 to +65
<95
IP66 (Indoor or Outdoor)
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s
> 1,000,000

hr

Block Diagram

Port 1
1850-1910/
1930-1990

DC/AISG Bypass

DC/AISG Bypass

Port 3

Port 2
1710-1755/
2110-2155

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

125

Issued: Dec10
Control: 2-0-0
1/1

Wideband Diplexer
Band 1: 380-960MHz Band 2: 1710-2700MHz
CM-FK2-ODx, CM-FK2D-ODx (x= 1, 2, 3 or 4, Preconfigured DC-pass)

Features and Product Description

Extra wideband design for feeder sharing between systems in the 380-960MHz
range and the 1710-2700MHz range.
Long connectors allow ease of waterproofing.
High power handling and low loss maximizes system performance..
Built with optional DC bypass, to be used with Tower Mounted Amplifiers and
AISG compliant devices.
Wall or pole mounting available
Available as a single unit or double unit

Single unit Photo for reference

Technical Specifications
Electrical
Pass Band Frequency Range
Insertion Loss
Isolation between Bands
Return Loss
Maximum input power per port
Intermodulation Products
Impedance

MHz
dB
dB
dB
W
dBc

380-960
0.2

1710-2700
0.2
60
20

300

500
-155 @2 x 43dBm
50

Mechanical
Dimension (LxWxH) (including
connectors and mounting kits)
Weight (include
connectors
and mounting kits)
Colors
Housing
RF Connectors
Mounting Kit

Single unit
Double unit
Single unit
Double unit

309x110x82(12.2x4.3x3.2)
309x110x135(12.2x4.3x5.3)
3.0(6.6)
5.5(12.1)
Light grey
Aluminum
DIN 7/16 female
Pole (clamps included for 35-125mm) or wall mounted

mm (in)
kg (lb)

Environmental Characteristics
o

Operating Temperature Range


Operational Humidity
Environment Class
EMC
Lightning Protection
MTBF

C
%

-40 to +65
<95
IP66
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s
> 1,000,000

hr

Ordering Information and Block Diagram


Single unit Model Number
CM-FK2-OD1
CM-FK2-OD2
CM-FK2-OD3
CM-FK2-OD4

Double unit Model Number


CM-FK2D-OD1
CM-FK2D-OD2
CM-FK2D-OD3
CM-FK2D-OD4

DC Bypass Optional
No DC Path
DC Path in Low Frequency Band
DC Path in High Frequency Band
Full DC Path

Port 1
380-960

DC/AISG Bypass

DC/AISG Bypass

Port 3

Port 2
1710-2700

Example: View of single unit CM-FK2-OD4


Information contained in this document is subject to confirmation at time of ordering.
http://www.comba-telecom.com

126

Issued: Nov.12
Control: 1-0-0
1/1

Triple-band Combiner
Band 1: 380-960MHz Band 2: 1710-1880MHz Band3:1920-2170MHz
CM-FDW3-ODx, CM-FDW3D-ODx (x= 1, 2 or 6, Preconfigured DC-pass)

Features and Product Description


Designed for feeder sharing and co-location purpose
High power handling and low loss maximizes system performance
750W maximum output power rating
High isolation minimizes interference
Build with optional DC (AISG signals) bypass
Available as a single unit or double unit
Dual Unit photo for reference

Technical Specifications
Electrical
Pass Band Frequency Range
Insertion Loss

MHz
dB

Isolation between Bands

dB

Return Loss
Maximum input power pre port
Intermodulation Products
Impedance

dB
W
dBc

380-960
0.3

250

1710-1880
1920-2170
0.3
0.3
50 (380-960/1710-1880MHz)
50 (380-960/1920-2170MHz)
50 (1710-1880/1920-2170MHz)
20
250
250
-155 @2x43dBm
50

Mechanical
Dimensions, LxWxH
(including mounting brackets)
Weight
(including mounting brackets)
Colors
Housing
RF Connectors
Mount Kit

Single Unit
Double Unit
Single Unit
Double Unit

mm (in)
mm (in)
kg (lb)
kg (lb)

349x190x84(13.7x7.5x3.3)
349x190x136(13.7x7.5x5.4)
3.2(7.1)
6.4(14.1)
Light grey
Aluminum
7/16 DIN-Female
Pole (clamps included for 35-125mm Pole) or Wall mount

Environmental Characteristics
o

Operating Temperature Range


Operational Humidity
Environment Class
EMC
Lightning Protection
MTBF

C
%

-40 to +65
<95
IP66 (Indoor or Outdoor)
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s
> 1,000,000

hr

Ordering Information and Block Diagram


Single unit Model Number
CM-FDW3-OD1
CM-FDW3-OD2
CM-FDW3-OD3
CM-FDW3-OD4
CM-FDW3-OD5
CM-FDW3-OD6

Double unit Model Number


CM-FDW3D-OD1
CM-FDW3D-OD2
CM-FDW3D-OD3
CM-FDW3D-OD4
CM-FDW3D-OD5
CM-FDW3D-OD6

DC Bypass Optional
No DC Path
DC Path in Low Frequency Band
DC Path in Mid Frequency Band
DC Path in High Frequency Band
DC Path in Mid and High Frequency Band
Full DC Path

DC Bypass

Port 1
380-960

DC Bypass

Port 4

DC Bypass

Port 2
1710-1880

Port 3
1920-2170

Example: View of Single unit CM-FDW3-OD6


Information contained in this document is subject to confirmation at time of ordering.
http://www.comba-telecom.com

127

Issued: Nov.12
Control: 1-0-0
1/1

Triple-band Combiner
Band 1: 380-960MHz Band 2: 1710-2170MHz Band3:2300-2690MHz
CM-FKY3-ODx, CM-FKY3D-ODx (x= 1, 2 or 6, Preconfigured DC-pass)

Features and Product Description


Designed for feeder sharing and co-location purpose
High power handling and low loss maximizes system performance
750W maximum output power rating
High isolation minimizes interference
Build with optional DC (AISG signals) bypass
Available as a single unit or double unit

Single Unit photo for reference

Technical Specifications
Electrical
Pass Band Frequency Range
Insertion Loss

MHz
dB

Isolation between Bands

dB

Return Loss
Maximum input power per port
Intermodulation Products
Impedance

dB
W
dBc

380-960

250

1710-2170
2300-2690
0.3
60 (380-960/1710-2170MHz)
60 (380-960/2300-2690MHz)
55 (1710-2170/2300-2690MHz)
20
250
250
-155 @2x43dBm
50

Mechanical
Single Unit
Double Unit
Single Unit
Double Unit

Dimensions, LxWxH
(including mounting brackets)
Weight
(including mounting brackets)
Colors
Housing
RF Connectors
Mount Kit

321x167x81(12.6x6.6x3.2)
321x167x130(12.6x6.6x5.1)
2.7(5.9)
5.6(12.3)
Light grey
Aluminum
7/16 DIN-Female
Pole (clamps included for 35-125mm Pole) or Wall mount

mm (in)
kg (lb)

Environmental Characteristics
o

Operating Temperature Range


Operational Humidity
Environment Class
EMC
Lightning Protection
MTBF

C
%

-40 to +65
<95
IP66
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s
> 1,000,000

hr

Ordering Information and Block Diagram


Single unit Model Number
CM-FKY3-OD1
CM-FKY3-OD2
CM-FKY3-OD3
CM-FKY3-OD4
CM-FKY3-OD5
CM-FKY3-OD6

Double unit Model Number


CM-FKY3D-OD1
CM-FKY3D-OD2
CM-FKY3D-OD3
CM-FKY3D-OD4
CM-FKY3D-OD5
CM-FKY3D-OD6

DC Bypass Optional
No DC Path
DC Path in Low Frequency Band
DC Path in Mid Frequency Band
DC Path in High Frequency Band
DC Path in Mid and High Frequency Band
Full DC Path

Port 1
380-960

DC Bypass

DC Bypass

Port 4

DC Bypass

Port 2
1710-2170

Port 3
2300-2690

Example: View of Single unit CM-FKY3-OD6


Information contained in this document is subject to confirmation at time of ordering.
http://www.comba-telecom.com

128

Issued: Nov.2012
Control: 1-0-0
1/1

Quad-band Combiner
Band 1: 380-960MHz Band 2: 1710-1880MHz Band3:1920-2170MHz
Band4:2500-2690MHz
CM-FDWY4-ODx,CM-FDWY4D-ODx(x= 1, 2 or 8, Preconfigured DC-pass)

Features and Product Description

Single Unit photo for reference

Technical Specifications
Electrical
Pass Band Frequency Range
Insertion Loss
Isolation between Bands
Return Loss
Maximum input power per port
Intermodulation Products
Impedance

MHz
dB
dB
dB
W
dBc

380-960

1710-1880
1920-2170
0.3
50
20
250
250
-155 @2x43dBm
50

250

2500-2690

250

Mechanical
Dimensions,
connectors
brackets)

LxWxH(including
and
mounting

Single Unit
Double Unit
Single Unit
Double Unit

Weight(approx.)

370x210x84(14.6x8.3x3.3)

mm
(in)

370x210x138(14.6x8.3x5.4)
3.8(8.4)
7.8(17.2)
Light grey
Aluminum
7/16 DIN-Female
Pole (clamps included for 35-125mm Pole) or Wall mount

kg (lb)

Colors
Housing
RF Connectors
Mount Kit

Environmental Characteristics
o

Operating Temperature Range


Operational Humidity
Environment Class
EMC
Lightning Protection
MTBF

C
%

-40 to +65
<95
IP66(Indoor or Outdoor)
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s
> 1,000,000

hr

Ordering Information and Block Diagram

Port 1
380-960
-

Port2
1710-1880

DC Bypass Optional
No DC Path
DC Path in F Frequency Band
DC Path in D Frequency Band
DC Path in W Frequency Band
DC Path in Y Frequency Band
Full DC Path

Port 3
1920-2170

DC Bypass

Double unit Model Number


CM-FDWY4D-OD1
CM-FDWY4D-OD2
CM-FDWY4D-OD3
CM-FDWY4D-OD4
CM-FDWY4D-OD5
CM-FDWY4D-OD8
Port 5

DC Bypass

Single unit Model Number


CM-FDWY4-OD1
CM-FDWY4-OD2
CM-FDWY4-OD3
CM-FDWY4-OD4
CM-FDWY4-OD5
CM-FDWY4-OD8

DC Bypass

Designed for feeder sharing and co-location purpose


High power handling and low loss maximizes system performance
High isolation minimizes interference
Built with full band DC bypass, to be used with Tower Mounted Amplifiers and AISG
compliant devices.
Available as a single unit or double unit

DC Bypass

Port 4
2500-2690

Example: View of Single unit CM-FDWY4-OD8

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

129

Issued: Nov. 2012


Control: 1-0-0
1/1

FP-G75-D01
885-915/930-960MHz Band Pass Filter
Features and Product Description

100W High power handling.


Low Return Loss maximizes system performance.
Low Intermodulation.
Compact minimizes space requirements

Technical Specifications
Electrical
Pass band
Out band rejection
Insertion Loss

Uplink: 885-915
Downlink:930-960
45dB@869-882.5
1.0
1.5
0.5
1.3
100
500@+60C 1atm
< -155 @2 x 43dBm
50

MHz
MHz
Rx (886-915 MHz)
Rx (885-886 MHz)
Tx (930-960 MHz)

VSWR
Power Handling(average)
Peak power handling
PIM
Impedance

dB

W
W
dBc

Mechanical
Dimension (L x W x H) with mounting bracket
Weight (approx.)
DC / ASIG By-Pass
Material
Connector Type
Operational Humidity
Operational Temperature
Environmental Class
Lightning Protection
Installation
MTBF

mm
kg

445x126x92
2.8
By pass available, 40V / 3A
Aluminum
7/16 DIN-Female
< 95
-10 to +60
Indoor
Comply with IEC 61000-4-5; 8kA, 8/20s
Wall or Pole
> 500,000

%
C

hr

Block Diagram

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

130

Issued: Apr11
Control: 2-1-1
1/1

FP-C59-D01
824-837.5/869-882.5MHz Band Pass Filter
Features and Product Description

100W High power handling.


Low Return Loss maximizes system performance.
Low Intermodulation.
Compact minimizes space requirements

Technical Specifications
Electrical

W
W
dBc

Uplink: 824-837.5
Downlink:869-882.5
50dB@885-915
3.5 the lower the better
1.3
100
500@+60C 1atm
< -155 @2 x 43dBm
50

mm

278x100x47

kg

<5
Aluminum
7/16 DIN-Female
No
< 95
0 to +60
Indoor
No
Wall or Pole
> 500,000

Pass band

MHz

Out band rejection


Insertion Loss
VSWR
Power Handling(average)
Peak power handling
PIM
Impedance

MHz
dB

Mechanical
Dimension (L x W x H)
(exclude connectors and brackets)
Weight (approx.)
Material
Connector Type
Bypass function
Operational Humidity
Operational Temperature
Environmental Class
Lightning Protection
Installation
MTBF

%
C

hr

Block Diagram

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

131

Issued:Feb12
Control: 0-0-1
1/1

FP-G1216-D02
907-960MHz GSM Band Pass Filter
Features and Product Description

100W High Power.


No tuning required.
Low Return Loss maximizes system performance.
Low Intermodulation.
Compact minimizes space requirements

Technical Specifications
Electrical
Frequency Range

MHz

Bandwidth
Power Handling
Insertion Loss
Return Loss
In-Band Ripple
Out-of-Band Rejection
PIM
Impedance

MHz
W
dB
dB
dB
dB
dBc

Uplink: 907-915
Downlink: 952-960
53
100
1.0
18
0.8
50 @ 869-894MHz
-155 @2 x 43dBm
50

Mechanical
Dimension (L x W x H)
Weight (approx.)
Material
Connector Type
Operational Humidity
Operational Temperature
Environmental Class

287x150x66including mounting brackets


5
Aluminum
7/16 DIN-Female
< 95
-40 to +85
Outdoor, IP65

mm
kg

%
C

47

Port1

Port2

Port3

Port4

152

64

Outline Drawing

157
287

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

132

st

Issued:1 June11
Control: 1-0-0
1/1

FP-G1216-D01
903-915/ 948-960MHz GSM Band Pass Filter
Features and Product Description

100W High Power.


No tuning required.
Low Return Loss maximizes system performance.
Low Intermodulation.
Compact minimizes space requirements

Technical Specifications
Electrical
Frequency Range

MHz

Bandwidth
Power Handling
Insertion Loss

MHz
W
dB

Return Loss

dB

In-Band Ripple
Out-of-Band Rejection at normal temperature
Out-of-Band Rejection at -40C and +85C
PIM
Impedance

dB
dB
dB
dBc

Uplink: 903-915
Downlink: 948-960
12
100
1.0
18
17(-40C to +85C)
0.8
48 @ 869-894MHz
45 @ 869-894MHz
-150 @2 x 43dBm
50

Mechanical
Dimension (L x W x H)
Weight (approx.)
Material
Connector Type
Operational Humidity
Operational Temperature
Environmental Class

mm
kg

287x150x66 (including mounting brackets)


5
Aluminum
7/16 DIN-Female
< 95
-40 to +85
Outdoor, IP65

%
C

47

Port1

Port2

Port3

Port4

152

64

Outline Drawing

157
287

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

133

Issued:24Aug2010
Control: 2-0-0
1/1

FP-G15D-OD01
900.1-915/945.1-960MHz Band Pass Filter
Features and Product Description

100W High power handling.

Low Insertion Loss maximizes system performance.

Low Passive Intermodulation.

Compact minimizes space requirements.

Dual units design.

Technical Specifications
Electrical Characteristics
Pass band
Out band rejection
Insertion Loss

dB
W
W
dBc

RX:900.1-915
TX:945.1-960
30dB@869-894
1.0
0.4
20
100
800
<-150@2 x 43dBm
50

mm

157 x 152 x 47

kg

3
By pass available, 40V / 3A
Aluminum
7/16 DIN-Female
< 95
-40 to +65
Outdoor
Comply with IEC 61000-4-5; 8kA, 8/20s
Wall or Pole
> 500,000

MHz
MHz
Rx (900.1-915 MHz)
Tx (945.1-960 MHz)

Return Loss
Power Handling(average)
Peak power handling
PIM
Impedance

dB

Mechanical Characteristics
Dimension (L x W x H, without mounting bracket
and connectors)
Weight (approx.)
DC / AISG By-Pass
Material
Connector Type
Operational Humidity
Operational Temperature
Environmental Class
Lightning Protection
Installation
MTBF

%
C

hr

Block Diagram

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

134

th

Issued: 9 Mar.12
Control: 1-0-1
1/2

FP-G15D-OD01
900.1-915/945.1-960MHz Band Pass Filter
Outline Drawing

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

135

th

Issued: 9 Mar.12
Control: 1-0-1
2/2

FP-C22-D01
824-846.5/869-891.5MHz Band Pass Filter
Features and Product Description

100W High power handling.


Low Return Loss maximizes system performance.
Low Intermodulation.
Compact minimizes space requirements
Photo for reference

Technical Specifications
Electrical
Stop band Frequency Range

MHz

Bandwidth
Insertion Loss
Return Loss
Power Handling(average)
Peak power handling
Out-of-Band Rejection
PIM
Impedance

MHz
dB
dB
W
W
dB
dBc

Uplink: 824-846.5
Downlink:869-891.5
22.5
< 1.4
> 18
100
800
> 54@ 851-866MHz
< -155 @2 x 46dBm
50

Mechanical
Dimension (L x W x H)
Weight (approx.)
Material
Connector Type
Bypass function
Max DC bypass current
Operational Humidity
Operational Temperature
Environmental Class
Lightning Protection
Installation
MTBF

mm
kg

250x250x61(without brackets and connectors)


6
Aluminum
7/16 DIN-Female
DC&AISG, 12-30V
>2.3
< 95
-40 to +65
Outdoor, IP67
Comply with IEC 61000-4-5; 8kA, 8/20s
Wall or Pole
> 500,000

A
%
C

hr

Block Diagram

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

136

Issued:Sep10
Control: 0-0-0
1/1

FP-C60-D01
824-884 UMTS850 Band Pass Filter
Features and Product Description

No tuning required.
Low Return Loss maximizes system performance.
Good Intermodulation.
Compact minimizes space requirements
Outdoor application.

Technical Specifications
Electrical
Pass Band Frequency Range
Stop Band
Power Handling

MHz
MHz
W

Insertion Loss
VSWR
Out-of-Band Rejection

dB
dB
dB

PIM

dBc

Impedance

824-884
897.5-915
>80W (average power WCDMA signal, 869 - 884 MHz)
>400W (peak power, 869 - 884 MHz)
1.0
<1.35
50 @ 897.5-915MHz
IM3:<-150dBc @2x43dBm carrier
IM7:<-160dBc @2x43dBm carrier
50

Mechanical
Dimension (L x W x H)
Weight (approx.)
Material
Connector Type
DC, AISG by-pass
Lightning Protection
Operational Humidity
Operational Temperature
Environmental Class

mm
kg

178x92x53.5
2
Sliver plated aluminum unpainted
7/16 DIN-Female
Support
Comply with IEC 61000-4-5; 8kA, 8/20s
< 95
0 to +65
Outdoor(IP66)

%
C

Mechanical Outline Drawing

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

137

Issued:27June11
Control:2-0-0
1/1

DU-E7030-D01
885-915/ 930-960MHz EGSM Duplexer
Features and Product Description

150W High Power.


No tuning required.
Low Return Loss maximizes system performance.
Compact minimizes space requirements.

Technical Specifications
Electrical
Frequency Range

RX
TX

Bandwidth
Average Power Handling
Insertion Loss
Return Loss
TX/RX Isolation
PIM @2x43dBm
Impedance

885-915
930-960
30
150
1.0
18
70
< -155REVERSE
50

MHz
MHz
W
dB
dB
dB
dBc

Mechanical
Dimension (L x W x H) (approx.)
Weight (approx.)
Material
Connector Type
Mounting Bracket
Operational Humidity
Operational Temperature
Environmental Class

mm
kg

157x284x76.5
2.5
Aluminum
7/16 Din-Female
Wall Mount/Pole Mount
< 95
-20 to +60
Indoor

%
C

Mechanical Outline Drawing

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

138

st

Issued:1 Sep11
Control: 1-0-0
1/1

DU-D8005-D03
1710-1785/ 1805-1880MHz GSM1800 Duplexer
Features and Product Description

100W average power handling.


No tuning required.
Low Return Loss maximizes system performance.
Compact minimizes space requirements.

Technical Specifications
Electrical
Frequency Range

RX
TX

Bandwidth
Average Power Handling
Insertion Loss
Return Loss
TX/RX Isolation
PIM
Impedance

1710-1785
1805-1880
75
100
0.6
>20
80
< -150@2x43dBm
50

MHz
MHz
W
dB
dB
dB
dBc

Mechanical
Dimension (L x W x H)
Weight (approx.)
Material
Connector Type
Operational Humidity
Operational Temperature
Environmental Class

mm
kg

248x210x36
3.0
Aluminum
7/16 Din-Female
%
< 95
C
-10 to +50
Indoor
Note: Measurements taken at room temperature, unless otherwise stated.

Mechanical Outline Drawing

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

139

th

Issued:4 Sep2011
Control: 0-0-1
1/1

FP-G11D-OD01
902.1-913.1/947.1-958.1MHz Band Pass Filter
Features and Product Description

100W High power handling.

Low Insertion Loss maximizes system performance.

Low Passive Intermodulation.

Compact minimizes space requirements.

Dual units design.

Technical Specifications
Electrical Characteristics
Pass band
Out band rejection
Insertion Loss

RX:902.1-913.1
TX:947.1-958.1
35dB@869-894
1.0
0.4
20
100
800
<-150@2 x 43dBm
50

MHz
MHz
Rx (902.1-913.1 MHz)
Tx (947.1-958.1 MHz)

Return Loss
Power Handling(average)
Peak power handling
PIM
Impedance

dB
dB
W
W
dBc

Mechanical Characteristics
Dimension (L x W x H, excluding mounting
bracket and connectors)
Weight (approx.)
DC / AISG By-Pass
Material
Connector Type
Operational Humidity
Operational Temperature
Environmental Class
Lightning Protection
Installation
MTBF

mm
(in)
kg (lb)

157x152x47(6.2x6.0x1.9)
3(6.6)
By pass available, 40V / 3A
Aluminum
7/16 DIN-Female
< 95
-40 to +65
Outdoor
Comply with IEC 61000-4-5; 8kA, 8/20s
Wall or Pole
> 500,000

%
C

hr

Block Diagram

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

140

Issued: Nov.12
Control: 2-0-0
1/2

FP-G11D-OD01
902.1-913.1/947.1-958.1MHz Band Pass Filter
Outline Drawing

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

141

th

Issued: 9 Mar.12
Control: 1-0-4
2/2

FP-G26D-D01
890.1-903.7/935.1-948.7 900MHz Band Pass Filter
Features and Product Description

No tuning required.
Low Return Loss maximizes system performance.
Good Intermodulation.
Compact minimizes space requirements
Outdoor application.
Dual Unit.

Technical Specifications
Electrical

dB
W

890.1-903.7(Factory tunable from 887 to 903.7MHz)


935.1-948.7(Factory tunable from 932 to 948.7MHz)
40 @ 800-889.515MHz
(Note: guard band of 585kHz must be maintained)
1.5 @ band edge
0.3(typ.)
0.4, 0.3(typ.)
1.2
0.15
19
100/1000

dBc

-160(IM3@2x43dBm)

Group Delay Variation (any 200KHz) in RX

ns

400,10(typ.)

Group Delay Variation across pass band in RX

ns

900

Absolute Delay in RX
Impedance

ns

1100
50

Mm(in)

334x395x176(13.1x15.6x6.9)

Kg(lb)

21(46.3)
Sliver plated aluminum unpainted
Port 1:BTS 7/16 DIN-Female
Port 2:ANT 7/16 DIN-Female
Pole (clamps included for 35-125mm Pole) or Wall mount

Pass Band Frequency


Range

RX Band
TX Band

Out-of-Band Rejection
Insertion Loss

MHz
dB

890.1-903.7MHz
935.1-948.7MHz
890.1-903.7MHz
935.1-948.7MHz

Insertion Loss
Variation
Return Loss
Power Handling(Avg./Peak)
PIM

dB
dB

Mechanical
Dimension (L x W x H)
(excluding connectors and brackets)
Weight (approx.)
Material
Connector Type
Mount Kit

DC/AISG by-pass
Compliant to
Passband
Insertion Loss
Return Loss
Input Voltage/Current

3GPP TS 25.466 version 9.2.0 Release 9


0-3
1
12
33V max, 1A max

MHz
dB
dB

Environmental Characteristics
Operating Temperature Range
Operational Humidity
Environment Class
EMC
Lightning Protection
MTBF

C
%

-10 to +60
<95
Outdoor(IP67)
ETS 300 342-3
Comply with IEC 61000-4-5; 8kA, 8/20s
> 1,000,000

hr

Mechanical Outline Drawing

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

142

Issued:Nov.12
Control:2-0-0
1/1

FP-G26D-D01
890.1-903.7/935.1-948.7 900MHz Band Pass Filter

IN1
DC

OUT1
DC

IN2
DC

OUT2
DC

Fig 1 Outline Drawing

Fig 2 Pole Mounting


Information contained in this document is subject to confirmation at time of ordering.
http://www.comba-telecom.com

143

Issued:Nov.12
Control:2-0-0
1/1

FP-G26D-D01
890.1-903.7/935.1-948.7 900MHz Band Pass Filter
Simulation Curves

Fig 3 Simulation Curves

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

144

Issued:Nov.12
Control:2-0-0
1/1

2:1 Hybrid Combiner


698-2700MHz
COM-BD21ODN3
Features and Product Description

698-2700MHz Frequency Range.


100W average power handling capability per port.
Low insertion loss.
Terminated with Low PIM performance using cable load.
Integrating two operators services into an existing in-building antenna distribution
system.
RoHS Compliant.

Photo for reference

Technical Specifications
Electrical
Frequency Range
Input Avg. Power, max at each port
Input Peak Power at each port
698-806MHz
Coupling Attenuation
806-2700MHz
698-2170MHz
Isolation between Bands
2170-2700MHz
Return Loss
PIM(3rd Order)
Impedance

MHz
W
W
dB
dB
dB
dB
dB
dBc

698-2700
100
1500
3.10.6
3.10.5
25*
23*
18
-155 @2x43dBm
50

mm (in)

260x190x86(10.3x7.5x3.4)

Mechanical
Dimension, LxWxH ( Excluding connectors
and brackets) ,approx.
Weight, approx.
Material
Inner Plating
Connector Type
Operational Temperature
Operational Humidity
Environmental Class
Mounting Kit

kg (lb)

C
%

6.6(14.5)
Aluminum
Silver
7/16 DIN-Female
-40 to +65
< 95
Indoor or Outdoor,IP66
Pole (clamps included for 35-125mm) or wall mounted
* Valid if all ports are terminated with 50 load

Block Diagram

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

145

Issued: Nov.2012
Control: 2-0-0
1

2:1 Hybrid Combiner


698-2700MHz
COM-BD21ODN3
Outline Drawing

190

118.7
86.7

260
379

361
323

8.5

112.8
120

Diagram

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

146

Issued: Nov.2012
Control: 2-0-0
2

3dB Wideband Hybrid Coupler


698-2700MHz, 7-16 DIN-Female,150W
HC-R-OD150L
Features and Product Description

Wideband covering 698-2700MHz.


150Watt per port input power handling capability.
Suitable for both indoor and outdoor applications.
Compact and cost effective solution for combining two bands.
Low insertion loss and VSWR, high isolation.
Integrating two operators services into an existing in-building antenna distribution
system.
High reliability.
RoHS Compliant.

Technical Specifications
Electrical
Frequency Range
Input Avg. Power, max at each port
Peak Power, maximum
Insertion Loss
Coupling Value
Coupling Tolerance
Isolation between Bands
VSWR
PIM
Impedance

MHz
W
W
dB
dB
dB
dB

698-2700
150
1000
0.2
3.1
0.5
23*
1.2*
-140 @2x43dBm
50

dBc

Mechanical
Dimension, LxWxH
Weight
Material
Inner Plating
Connector Type
Operational Temperature
Operational Humidity
Environmental Class

mm (in)
kg (lb)

133x90x38 (5.2x3.5x1.5)
1.0 (2.2)
Aluminum
Silver
7-16 DIN-Female
-25 to +65
< 95
Indoor/Outdoor IP65
* Valid if all ports are terminated with 50 load

C
%

Outline Drawing

125

83

90

47

38

133

HC-R-OD150L

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

147

Issued: June2010
Control: 3-0-0
1

3dB Wideband Hybrid Coupler


698-2700MHz, N-Female,150W
HC-R-ON150L
Features and Product Description

698-2700MHz Multi-band Frequency Range.


200Watt average power handling capability.
Suitable for both indoor and outdoor applications.
Compact and cost effective solution for combining two bands.
Low insertion loss and VSWR, high isolation and good PIM performance.
Integrating two operators services into an existing in-building antenna distribution
system.
High reliability.
RoHS Compliant.

Technical Specifications
Electrical
Frequency Range
Input Avg. Power, max at each port
Peak Power, maximum
Insertion Loss
Coupling Value
Coupling Tolerance
Isolation between Bands
VSWR
PIM
Impedance

MHz
W
W
dB
dB
dB
dB

698-2700
150
1000
0.2
3.1
0.5
23*
1.2*
-140 @2x43dBm
50

dBc

Mechanical
Dimension, LxWxH
Weight
Material
Inner Plating
Connector Type
Operational Temperature
Operational Humidity
Environmental Class

mm (in)
kg (lb)

133x76x25 (5.2x3.0x1.0)
0.5 (1.1)
Aluminum
Silver
N-Female
-25 to +65
< 95
Indoor/Outdoor IP65
* Valid if all ports are terminated with 50 load

C
%

Outline Drawing

40
76

4 .5

125

83
133

25

HC-R-ON150L

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

148

Issued: June2010
Control: 3-0-0
1

Hybrid Coupler
HC-x-D200L, HC-x-N200L
Features and Product Description

Compact and cost effective combining of CDMA, GSM and UMTS signals.
200W power handling capability and inter-band isolation.
Low insertion loss.
Two combined output ports for split cable systems.
Integrating two operators services into an existing in-building antenna
distribution system.
HC-M-D200L shown

Technical Specification
Electrical
Frequency Range
Input Power
Dissipative Loss
Coupling Value
Isolation between Bands
Group Delay
Pass Band Ripple
VSWR
Impedance

MHz
W
dB
dB
dB
nsec
dB

B band

K band

M band

800 960

1710 2200
200
0.2
3
30
1
0.5
1.15 : 1
50

800 2500

0.15
35

1.10 : 1

0.3
25

1.20 : 1

Mechanical
Dimension
(L x W x H)
Weight

7/16 DIN-Female
Type N-Female
7/16 DIN-Female
Type N-Female

Material
Operational Temperature
Operational Humidity
Environmental Class

mm
kg
o

95 x 79.8 x 37
88 x 66 x 20
0.7
0.2

92 x 101 x 37
88 x 87 x 20
0.6
0.3
Aluminum
-30 to +75
< 95
Indoor

133 x 90 x 38
133 x 76 x 23
1
0.5

IP65

Ordering Information
Freq Band
800 960 MHz
1710 2200 MHz
800 2500 MHz

7/16 DIN connector


HC-B-D200L
HC-K-D200L
HC-M-D200L

Type N connector
HC-B-N200L
HC-K-N200L
HC-M-N200L

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com
RB-NKC1 RB-DKF0 RB-NKF0 RB-DKW0 RB-NKW0

149

th

Issued: 10 Mar11
Control: 3-0-3
1/1

4in 4 out Hybrid Coupler


HC-R4-ON60L, HC-R4-OD60L
Features and Product Description

Compact and cost effective same band combining of 698-2700MHz signals.

High inter-band isolation.

Low insertion loss.

The use of fewer than 4 inputs or outputs is possible. Any unused input ports have to be terminated with
low-power 50 loads, unused output ports have to be terminated with high-power 50 loads.

Suitable for indoor or outdoor applications

Technical Specification
Electrical
Frequency Range
Input Power
Insertion Loss
Coupling Value
Coupling Tolerance
Isolation between Bands
VSWR
Impedance

MHz
W
dB
dB
dB
dB

698-2700
60 max at each port
0.5
6.2
1.1
20*
1.2*
50

Mechanical
7/16 DIN-Female
Type N-Female
7/16 DIN-Female
Type N-Female

Dimensions
(L x W x H)
Weight

196x196xx36
183x183x26
3.1
1.7
Aluminum
-25 to +65
< 95
Indoor/Outdoor(IP65)
* Valid if all ports are terminated with 50 load

mm
kg

Material
Operational Temperature
Operational Humidity
Environmental Class

C
%

Outline Drawing

144

85

154

183

137

85

147

4-

196

144

137

5
4.

85
147

85

26

154

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

150

36

th

Issued:26 Aug11
Control: 0-0-0
1/1

Wideband Reactive Power Splitter


2/3/4way,698-2700MHz,7-16 DIN-Female, 700W
PS-R2-OD700C,PS-R3-OD700C,PS-R4-OD700C
Features and Product Description

Wideband covering 698-2700MHz.


700Watt input power handling capability.
Low loss, flat response and even output.
Suitable for both indoor and outdoor applications.
High reliability.
RoHS Compliant.

Technical Specifications
Electrical
No. of Ways
Frequency Range
Average Power, maximum
Peak Power
Splitting Loss
In-band Ripple
Insertion loss
Input Port VSWR
PIM
Impedance

PS-R2-OD700C

PS-R3-OD700C

PS-R4-OD700C

2-way

3-way
698-2700
700
3000
4.8
0.2
0.1
< 1.25
-140 @2x43dBm
50

4-way

MHz
W
W
dB
dB
dB

3.0

< 1.20
dBc

6.0

< 1.30

Mechanical
Dimension, LxWxH

230x82x38
(9.1x3.2x1.5)
1.05 (2.3)

252x82x38
255x82x60
(9.9x3.2x1.5)
(10.0x3.2x2.4)
1.2 (2.7)
1.32 (2.9)
Aluminum
Silver
7-16 DIN-Female
-35 to +65
Wall mounted bracket provided
< 95
Indoor/Outdoor IP65

mm (in)

Weight
Material
Inner Plating
Connector Type
Operational Temperature
Mounting
Operational Humidity
Environmental Class

kg (lb)

38

82

PS-R2-OD700C

38

82

PS-R3-OD700C

82

Outline Drawing

PS-R4-OD700C

204
38

230

207
38

38

252

209
255

Mounting kits

38
60

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

151

Issued: Apr11
Control: 3-1-0
1

Wideband Reactive Power Splitter


2/3/4way,698-2700MHz, N-Female, 300W
PS-R2-ON300C,PS-R3-ON300C,PS-R4-ON300C
Features and Product Description

Wideband covering 698-2700MHz.


300Watt input power handling capability.
Low loss, flat response and even output.
Suitable for both indoor and outdoor applications.
High reliability.
RoHS Compliant.

Technical Specifications
Electrical
No. of Ways
Frequency Range
Average Power, maximum
Peak Power
Splitting Loss
In-band Ripple
Insertion loss
Input Port VSWR
PIM
Impedance

MHz
W
W
dB
dB
dB

PS-R2-ON300C

PS-R3-ON300C

PS-R4-ON300C

2-way

3-way
698-2700
300
3000
4.8
0.2
0.1
< 1.25
-140 @2x43dBm
50

4-way

3.0

< 1.20
dBc

6.0

< 1.30

Mechanical
Dimension, LxWxH

mm (in)

Weight
Material
Inner Plating
Connector Type
Operational Temperature
Mounting
Operational Humidity
Environmental Class

kg (lb)

211x61x25
(8.3x2.4x1.0)
0.38 (0.8)

227x61x25
227x61x43
(8.9x2.4x1.0)
(8.9x2.4x1.7)
0.42 (0.9)
0.46 (1.0)
Aluminum
Silver
N-Female
-35 to +65
Wall mounted bracket provided
< 95
Indoor/Outdoor IP65

25
61
25
61

196

PS-R2-ON300C

PS-R3-ON300C

25
61

Outline Drawing

PS-R4-ON300C

25

211

197
227

197
227

25

Mounting kits

25
43

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

152

Issued: Apr2011
Control: 3-1-0
1

Wideband In-line Wilkinson Power Splitter


2/3/4way,698-2700MHz ,N-Female, 50W
PS-R2-ON50M, PS-R3-ON50M, PS-R4-ON50M
Features and Product Description

698-2700MHz Multi-band Frequency Range.


50W power handling capability.
Low loss, flat response and even output.
Suitable for both indoor and outdoor applications.
RoHS compliant
20dB isolation

Technical Specifications
Electrical
No. of Ways
Frequency Range
Average Power at Input Port, maximum
Splitting Loss
Insertion loss
Input Port VSWR
Isolation between Ports
PIM
Impedance

PS-R2-ON50M

PS-R3-ON50M

PS-R4-ON50M

2-way

3-way
698-2700
50*
4.8
0.7

4-way

MHz
W
dB
dB

3.0
0.4

6.0
0.6
< 1.30
> 18

< 1.25
> 20
-130 @2x43dBm
50

dB
dBc

Mechanical
Dimension, LxWxH

mm (in)

Weight
Material
Inner Plating
Connector Type
Operational Temperature
Operational Humidity
Environmental Class

kg (lb)

C
%

107x59x22
(4.2x2.3x0.9)
0.2 (0.4)

135x91x22
129x121x22
(5.3x3.6x0.9)
(5.1x4.8x0.9)
0.5 (1.1)
0.6 (1.3)
Aluminum
Silver
N-Female
-25 to +65
< 95
Indoor and Outdoor (IP65)
*when output ports terminated to load(s) with VSWR<1.5:1

Outline Drawing
89

111

91

101
30

79

59

30

69

30

61

71

22

107

99
135

PS-R2-ON50M

22

PS-R3-ON50M

141

121

28
28

131

28

83

5
4.

93

22

129

PS-R4-ON50M

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

153

Issued: Oct.2012
Control: 3-0-3
1

Power Divider, 700W


PS-N2-D700C, PS-N3-D700C, PS-N4-D700C
Features and Product Description

Wideband operation in all frequency bands from 800-2500MHz.


700W power handling capability.
Low intermodulation.
Low loss, flat response and good balance.
Suitable for in-building systems.

Technical Specifications
Electrical
Frequency Range
Input Power
Dissipative loss
Splitting Loss
VSWR
3rd Order Intermodulation @ 2 43dBm Carrier
Impedance

MHz
W
dB
dB

2-way

3-way

4-way

3.0

800 2500
700
0.2
4.8
< 1.20 : 1
-140
50

6.0

dBc

Mechanical
Dimension (L x W x H)
Weight
Material
Connector Type
Operational Temperature
Operational Humidity
Environmental Class

mm
kg

230 x 82 x 38
1.13

C
%

259 x 82 x 38
1.25
Aluminum
7/16 DIN-Female
-30 to +75
< 95
Indoor

259 x 82 x 60
1.36

Ordering Information

2-way
3-way
4-way

7/16 DIN connector


PS-N2-D700C
PS-N3-D700C
PS-N4-D700C

Type N connector

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com
RD-52D/DP-F1, RD-53D/DP-F1, RD-54D/DP-F1

154

Issued: 02Feb07
Control: 3-0-1
1/1

Power Divider, 50W


PS-N2-N50M, PS-N3-N50M, PS-N4-N50M
Features and Product Description

Wideband designed for operating in all frequency bands from


800-2500MHz.
50W power handling capability.
Low loss, flat response and good balance.
Used for in-building systems.

Technical Specifications
Electrical

2-way

Frequency Range
Input Power
Dissipative Loss

MHz
W
800 960, 1710 2170MHz
2200 2500MHz

Splitting Loss
Output Isolation
VSWR

0.3
0.8
3.0

dB
dB

800 960, 1710 2170 MHz


2200 2500 MHz
800 960, 1710 2170 MHz
2200 2500 MHz

dB

Impedance

3-way
800 2500
50
0.5
0.8
4.8
20
18
1.2 : 1
1.4 : 1
50

4-way

0.4
0.8
6.0

Mechanical
Dimension (L x W x H)
Weight
Material
Connector Type
Operational Temperature
Operational Humidity
Environmental Class

mm
kg

107.2 x 57 x 21
0.30

C
%

129.2 x 89 x 22
0.48
Aluminum
Type N-Female
-30 to +75
< 95
Indoor

129.2 x 119 x 22
0.64

Ordering Information
7/16 DIN connector
2-way
3-way
4-way

Type N connector
PS-N2-N50M
PS-N3-N50M
PS-N4-N50M

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com
RD-52N/NP-B3, RD-53N/NP-B3, RD-54N/NP-B3

155

Issued: 02Feb07
Control: 3-0-1
1/1

Power Divider, 200W


PS-N2-N200C, PS-N3-N200C, PS-N4-N200C
Features and Product Description

Wideband designed for operating in all frequency bands from


800-2500MHz.
200W power handling capability.
Low intermodulation.
Low loss, flat response and good balance.
Suitable for in-building systems.

Technical Specifications
Electrical

2-way

Frequency Range
Input Power

MHz
W

Dissipative Loss

dB

Splitting Loss
In-Band Ripple
VSWR
3rd Order Intermodulation @ 2 x 43dBm Carrier
Impedance

dB
dB

3-way

4-way

800 2500
200,avg; 1500,peak
0.1@800-2200MHz
0.15@2200-2500MHz
3.0

4.8
0.5
< 1.20 : 1
-140
50

dBc

6.0

Mechanical
Dimension (L x W x H)
Weight
Material
Connector Type
Operational Temperature
Operational Humidity
Environmental Class

mm
kg

211 x 61 x 25
0.29

C
%

229 x 61 x 25
0.34
Aluminum
Type N-Female
-25 to +75
< 95
Indoor

236 x 61 x 43
0.39

Ordering Information
7/16 DIN connector
2-way
3-way
4-way

Type N connector
PS-N2-N200C
PS-N3-N200C
PS-N4-N200C

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com
RD-52N/NP-F2, RD-53N/NP-F2, RD-54N/NP-F2

156

Issued: 08Oct08
Control:3-2-0
1/1

Power Divider, 200W


PS-Z2-N200C, PS-Z3-N200C, PS-Z4-N200C
Features and Product Description

Wideband designed for operating in all frequency bands between


800-2700MHz.
200W power handling capability.
Low loss, flat response and good balance.
Low intermodulation.
Suitable for in-building systems.

Technical Specifications
Electrical
Frequency Range
Input Power
Dissipative Loss
Splitting Loss
VSWR
3rd Order Intermodulation @ 2 43dBm Carrier
Impedance

2-way

3-way

4-way

3.0

824 960 / 1710 2700


200
0.2 (Typ.)
4.8
< 1.30 : 1
-140
50

6.0

MHz
W
dB
dB
dBc

Mechanical
Dimension (L x W x H)
Weight
Material
Connector Type
Operational Humidity
Operational Temperature
Environmental Class

mm
kg

191 x 61 x25
0.26

C
%

222.8 x 61 x 25
0.31
Aluminum
Type N-Female
-35 to +75
< 95
IP55

222.8 x 61 x 43
0.37

Ordering Information

2-way
3-way
4-way

Type N connector
PS-Z2-N200C
PS-Z3-N200C
PS-Z4-N200C

7/16 DIN connector

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com
IPD-Zx-N200S

157

Issued: 02Feb07
Control: 3-0-1
1/1

Wideband Coupler
6,10,15,20,30,40dB,698-2700MHz,N-Female, 200W
CO-Rxx-ON200C (xx=06, 10or 40, Preconfigured Coupling Value)

Features and Product Description

Wideband covering 698-2700MHz.


6, 10, 15, 20, 30 & 40dB coupling value.
200Watt average main line power handling capability.
Low insertion loss with high reliability.
Suitable for both indoor and outdoor applications.
RoHS Compliant.

Technical Specifications
Electrical
Frequency Range
Input Average Power
Peak Power
Coupling Value
Coupling tolerance
Main Line Loss
Input port VSWR
Insertion Loss
PIM
Impedance

MHz
W
W
dB
dB
dB

CO-R06ON200C

CO-R10ON200C

6
1.2
1.7

10
1.2
0.8
< 1.4

CO-R15CO-R20ON200C
ON200C
698-2700
200 (Maximum)
1000
15
20
1.2
1.5
0.4
0.2

CO-R30ON200C

CO-R40ON200C

30
1.5
0.2
< 1.2

40
1.5
0.2

0.1
-140 @2x43dBm
50

dB
dBc

Mechanical
Dimension, LxWxH
Weight
Material
Inner Plating
Connector Type
Temperature Range
Humidity
Environmental Class

mm
(in)
kg
(lb)

209x63x25 (8.2x2.5x1.0)

93x63x25 (3.7x2.5x1.0)

0.4 (0.9)

0.2 (0.4)
Aluminum
Silver
N-Female
-35 to +65
< 95
Indoor/Outdoor IP65

C
%

25

63

Outline Drawing

25
209

63

CO-R06-ON200C, CO-R10-ON200C, CO-R15-ON200C

25

3.2

25

93

CO-R20-ON200C, CO-R30-ON200C, CO-R40-ON200C

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

158

Issued: June2010
Control: 3-0-2
1

Indoor Coupler
30,40,55dB,820-960/1700-1900MHz,7/16 Din-Female,200W
CO-Bxx-D200C, CO-Dxx-D200C(xx=06, 10or 40, Preconfigured
Coupling Value)
Features and Product Description

Designed for CDMA800, GSM900 or GSM1800 band.


200W Power handling.
Low intermodulation.
High coupling values, low loss and flat coupling.
Compact design and high reliability.
Suitable for using in optical master unit as a coupler for RF power.

Technical Specifications
Electrical

Frequency Range
Input Power
Coupling Value
Insertion Loss
VSWR
3rd Order Intermodulation @ 2 43dBm Carrier
Impedance

MHz
W
dB
dB

band

D band

820 960

1700 1900

200
30 1.5, 40 1.5, 55 2.0
0.2
< 1.20 : 1
-140
50

dBc

Mechanical
Dimension (L x W x H)
Weight
Material

mm
kg

99.6 x 62.6 x 25
0.4
Aluminum
7/16 DIN
Type N-Female
-30 to +65
< 95
Indoor

Through ports
Couple port

Connector Type
Operational Temperature
Operational Humidity
Environmental Class

C
%

Outline Drawing & Ordering Information

xx Coupling Value
30dB
40dB
55dB

820 960 MHz


CO-B30-D200C
CO-B40-D200C
CO-B55-D200C

1700 1900 MHz


CO-D30-D200C
CO-D40-D200C
CO-D55-D200C

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

RC-5PJ/PK/NK-30C, RC-5PJ/PK/NK-40C, RC-5PJ/PK/NK-55C, RC-5PJ/PK/NK-30D, RC-5PJ/PK/NK-40D/55D

159

Issued: Aug10
Control: 3-0-2
1/1

Wideband Directional Coupler


5,6,7,8,10,13,15,20,30,40dB,698-2700MHz, 7-16 DIN-Female, 200W
DC-Rxx-OD200M (xx=05, 06or 40, Preconfigured Coupling Value)

Features and Product Description

Wideband covering 698-2700MHz.


5, 6,7,8,10,13,15,20,30 & 40dB coupling value.
200Watt average main line power handling capability.
Low main line loss with high reliability.
Suitable for both indoor and outdoor applications.
RoHS Compliant.

Technical Specifications
Electrical
Frequency Range
Input Average Power
Peak Power
Coupling Value
Coupling tolerance
Main Line Loss
Isolation
Input port VSWR
PIM
Impedance

MHz
W
W
dB
dB
dB
dB

DC-R05OD200M

DC-R06OD200M

5
0.8
2.3
> 25

6
0.8
1.7
> 26

dBc

DC-R07OD200M
698-2700
200 (Maximum)
1000
7
0.8
1.5
> 27
< 1.25
-140 @2x43dBm
50

DC-R08OD200M

DC-R10OD200M

8
0.8
1.2
> 28

10
1
0.8
> 30

Mechanical
Dimension, LxWxH
Weight
Material
Inner Plating
Connector Type
Temperature Range
Humidity
Environmental Class

mm
(in)
kg
(lb)

156x66x36 (6.1x2.6x1.4)
0.75 (1.7)
Aluminum
Silver
7-16 DIN-Female
-25 to +75
< 95
Indoor/Outdoor IP65
*13,15,20,30,40dB specs listed in next page

C
%

Outline Drawing

44

36

66

5.5

112
156

36

DC-R05-OD200M, DC-R06-OD200M,
DC-R07-OD200M, DC-R08-OD200M,
DC-R10-OD200M

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

160

Issued: Nov.2010
Control: 3-0-1
1/2

Wideband Directional Coupler


5,6,7,8,10,13,15,20,30,40dB,698-2700MHz, 7-16 DIN-Female, 200W
DC-Rxx-OD200M (xx=05, 06or 40, Preconfigured Coupling Value)

Features and Product Description

Wideband covering 698-2700MHz.


5, 6,7,8,10,13,15,20,30 & 40dB coupling value.
200Watt average main line power handling capability.
Low main line loss with high reliability.
Suitable for both indoor and outdoor applications.
RoHS Compliant.

Technical Specifications
Electrical
Frequency Range
Input Average Power
Peak Power
Coupling Value
Coupling tolerance
Main Line Loss
Isolation
Input port VSWR
PIM
Impedance

MHz
W
W
dB
dB
dB
dB

DC-R13OD200M

DC-R15OD200M

13
1
0.5
> 33

15
1
0.4
> 35

dBc

DC-R20OD200M
698-2700
200 (Maximum)
1000
20
1
0.3
> 40
< 1.25
-140 @2x43dBm
50

DC-R30OD200M

DC-R40OD200M

30
1.2
0.2
> 33

40
1.5
0.2
> 43

Mechanical
mm
(in)
kg
(lb)

Dimension, LxWxH
Weight
Material
Inner Plating
Connector Type
Temperature Range
Humidity
Environmental Class

156x66x36 (6.1x2.6x1.4)

156x70x36 (6.1x2.8x1.4)

0.75 (1.7)

0.85 (1.9)
Aluminum
Silver
7-16 DIN-Female
-25 to +75
< 95
Indoor/Outdoor IP65

C
%

Outline Drawing

112
156

36

DC-R13-OD200M,
DC-R15-OD200M,
DC-R20-OD200M

48

40

66
44

36
112
156

70

5.

5
5.

36

DC-R30-OD200M,
DC-R40-OD200M

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

161

Issued: Nov.2010
Control: 3-0-1
2/2

Wideband Directional Coupler


5,6,7,8,10,13,15,20,30,40dB,698-2700MHz, N-Female, 200W
DC-Rxx-ON200M (xx=05, 06or 40, Preconfigured Coupling Value)

Features and Product Description

Wideband covering 698-2700MHz.


5, 6,7,8,10,13,15,20,30 & 40dB coupling value.
200Watt average main line power handling capability.
Low main line loss with high reliability.
Suitable for both indoor and outdoor applications.
RoHS Compliant.

Technical Specifications
Electrical
Frequency Range
Input Average Power
Peak Power
Coupling Value
Coupling tolerance
Main Line Loss
Isolation
Input port VSWR
PIM
Impedance

MHz
W
W
dB
dB
dB
dB

DC-R05ON200M

DC-R06ON200M

5
0.8
2.3
> 25

6
0.8
1.7
> 26

dBc

DC-R07ON200M
698-2700
200 (Maximum)
1000
7
0.8
1.5
> 27
< 1.25
-140 @2x43dBm
50

DC-R08ON200M

DC-R10ON200M

8
0.8
1.2
> 28

10
1
0.8
> 30

Mechanical
Dimension, LxWxH
Weight
Material
Inner Plating
Connector Type
Temperature Range
Humidity
Environmental Class

mm
(in)
kg
(lb)

141x55x23 (5.6x2.2x0.9)
0.30 (0.7)
Aluminum
Silver
N-Female
-25 to +75
< 95
Indoor/Outdoor IP65
*13,15,20,30,40dB specs listed in next page

C
%

Outline Drawing
115

15

37

55

5
4.

23

105
141

DC-R05-ON200M, DC-R06-ON200M,
DC-R07-ON200M, DC-R08-ON200M,
DC-R10-ON200M

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

162

Issued: Nov.2010
Control: 3-0-1
1/2

Wideband Directional Coupler


5,6,7,8,10,13,15,20,30,40dB,698-2700MHz, N-Female, 200W
DC-Rxx-ON200M (xx=05, 06or 40, Preconfigured Coupling Value)

Features and Product Description

Wideband covering 698-2700MHz.


5, 6,7,8,10,13,15,20,30 & 40dB coupling value.
200Watt average main line power handling capability.
Low main line loss with high reliability.
Suitable for both indoor and outdoor applications.
RoHS Compliant.

Technical Specifications
Electrical
Frequency Range
Input Average Power
Peak Power
Coupling Value
Coupling tolerance
Main Line Loss
Isolation
Input port VSWR
PIM
Impedance

MHz
W
W
dB
dB
dB
dB

DC-R13ON200M

DC-R15ON200M

13
1
0.5
> 33

15
1
0.4
> 35

dBc

DC-R20ON200M
698-2700
200 (Maximum)
1000
20
1
0.3
> 40
< 1.25
-140 @2x43dBm
50

DC-R30ON200M

DC-R40ON200M

30
1.2
0.2
> 33

40
1.5
0.2
> 43

Mechanical
mm
(in)
kg
(lb)

Dimension, LxWxH
Weight
Material
Inner Plating
Connector Type
Temperature Range
Humidity
Environmental Class

141x55x23 (5.6x2.2x0.9)

141x59x23 (5.6x2.3x0.9)

0.30 (0.7)

0.40 (0.9)
Aluminum
Silver
N-Female
-25 to +75
< 95
Indoor/Outdoor IP65

C
%

Outline Drawing
115

115

4.

105

15

15

37

55

41
59

5
4.

105

23

23

141

141

DC-R30-ON200M,
DC-R40-ON200M

DC-R13-ON200M,
DC-R15-ON200M,
DC-R20-ON200M

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com

163

Issued: Nov.2010
Control: 3-0-1
2/2

Directional Coupler
DC-Nxx-D200M, DC-Nxx-N200M
Features and Product Description

Wideband designed for operating in all frequency bands from


800-2500MHz.
200W power handling capability.
Low loss and flat coupling.
Available with 7/16 DIN or Type N connector.
Used for power coupling with in-building systems.

Technical Specifications
Electrical

6dB

Frequency Range
Input Power
Dissipative Loss
Coupling Value
Main Line Loss
Directivity
VSWR
Impedance

MHz
W
dB
dB
dB
dB

10dB

15dB

20dB

800 2500
200
0.2
6
1.7

10
0.7

15
0.4

20
0.3

> 20
< 1.25 : 1
50

Mechanical
7/16 DIN-Female
Type N-Female
7/16 DIN-Female
Type N-Female

Dimension
(L x W x H)
Weight
Material
Operational Temperature
Operational Humidity
Environmental Class

155 x 65 x 36
141 x 55 x 22
0.75
0.3
Aluminum
-30 to +75
< 95
Indoor

mm
kg
o

C
%

Ordering Information
xx Coupling Value
6dB
10dB
15dB
20dB

7/16 DIN connector


DC-N06-D200M
DC-N10-D200M
DC-N15-D200M
DC-N20-D200M

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com
RC-5DK-06F, RC-5DK-10F, RC-5DK-15F, RC-5DK-20F, RC-5NK-06F, RC-5NK-10F, RC-5NK-15F

164

Type N connector
DC-N06-N200M
DC-N10-N200M
DC-N15-N200M
DC-N20-N200M

Issued: 02Feb07
Control: 3-0-1
1/1

Indoor wideband Coupler


6,10,15,20dB,800-2500MHz, N-Female, 200W
DC-Nxx-N200C (xx=06, 10or 20, Preconfigured Coupling Value)
Features and Product Description

Wideband designed for operating in all frequency bands from


800-2500MHz.
200W power handling capability.
Low loss, flat coupling and intermodulation.
Used for power coupling with in-building systems.

Technical Specifications
Electrical
Frequency Range
Input Power
Coupling Value
Main Line Loss
VSWR
3rd Order Intermodulation @ 2 43dBm Carrier
Impedance

6dB
MHz
W
dB
dB

10dB

15dB

800 2500
200
10
15
0.7
0.3
< 1.30 : 1
-140
50

6
1.6

dBc

20dB

20
0.3

Mechanical
Dimension ( L x W x H)
Weight
Material
Operational Temperature
Operational Humidity
Environmental Class

mm
kg

220 x 63 x 25
0.3
Aluminum
-35 to +75
< 95
Indoor

C
%

167 x 63 x 25
0.25

Outline Drawing

Information contained in this document is subject to confirmation at time of ordering.


http://www.comba-telecom.com
RC-5NK/NK/NK-06F1, RC-5NK/NK/NK-10F1, RC-5NK/NK/NK-15F1, RC-5NK/NK/NK-20F1

165

Issued: Aug10
Control: 3-0-2
1/1

POI-TDA2ODN4SG
Multi Operator Combiner - 1x iDEN, 1x EGSM, 2x GSM900, 3x GSM1800, 3x
UMTS2100

Features

High input power of 100W and 150W (iDEN)


Permits combining of 1x iDEN, 1x EGSM, 2xGSM900, 3x GSM1800,
and 3x UMTS2100.
Low insertion loss and passive intermodulation.
High inter-band isolation.
IP-65 chassis for outdoor mounting.

Product Description
POI-TDA2ODN4SG is a multi-operator combiner that is designed for
cost effective antenna sharing solution. This high power combiner is
designed to combine 1x iDEN, 1x EGSM, 2x GSM900, 3x GSM1800 and
3x UMTS2100 for in-building common antenna system. It can be
deployed in places such as convention centers, exhibition halls,
airports, underground tunnels and other large buildings.
Comba is capable of providing solutions for any combination of
frequency bands while keeping insertion loss to a minimum

Technical Specifications
Electrical

Mechanical

Frequency Range [MHz]


- iDEN
RX/TX(A):
- EGSM
RX/TX(A):
- GSM900
RX/TX(A):
RX/TX(B)
- GSM1800
RX/TX(A):
RX/TX(B):

- UMTS2100

RX/TX(C):
RX/TX(A):
RX/TX(B):
RX/TX(C):

Insertion Loss [dB]

Dimension LxWxH [mm] (approx.)


806-825/851-870

Weight (approx.) [kg]

880-890/925-935
890-900/935-945
900-915/945-960

Number of Output Ports Duplex

1710-1715/1805-1810
& 1720-1740/1815-1835
1740-1760/1835-1855
& 1715-1720/1810-1815
1760-1785/1855-1880
1920-1935.1/2110.3-2125.1&
1974.9-1979.7/2164.9-2169.7
1935.1-1950.1/2125.1-2140.1
&1969.9-1974.9/2159.9-2164.9
1950.1-1969.9/2140.1-2159.9

Signal Output at Monitor [dBc]

< 6.0

Isolation [dB]
- GSM900/GSM900/EGSM
- GSM1800/GSM1800
- UMTS2100/ UMTS2100
- Cross band

> 33
> 33
> 33
> 91

Return Loss [dB]


- Input port
- Output port

> 20
> 14

PIM product in RX band


(@2x 43dBm) [dBc]

Number of Input Ports - Duplex


Number of Monitor Ports
Connector Type Input / Output
Temperature Range [C]
Operating Humidity [%]
Mounting
Environmental Class

600500300
49
2
10
2
-30 2
7/16 DIN-Female
0 to +50
< 95
Wall Mount
IP-65

Shipping Information
Dimensions, H x W x D [mm] *
Weight [kg]

850750500
70

* Shipping in wooden crate

< -153

Impedance [ohm]

50

Input Power Rating Per Port [W]


- GSM900,GSM1800,UMTS2100
- iDEN

100
150

Information contained in this document is subject to confirmation at time of ordering.


Please visit our website at http://www.comba-telecom.com

166

Issued: 26th Mar.12


Control: 0-0-0
Page 1/1

POI-TDH2IDN1HK
Multi Operator Combiner - 4xGSM900,6xGSM1800,4xUMTS,3xLTE2.6G
Features

High input power of 150W.


Permits combining of GSM900, GSM1800, WCDMA2100 and LTE2.6G
services.
Low insertion loss.
High inter-band isolation.
Compact size.

Product Description
The POI-TDH2IDN1HK is one of a range of compact, low intermodulation,
cellular combiners for cost effective, multi-band in-building combining
systems. This high power combiner is designed to combine GSM900,
GSM1800, WCDMA2100 and LTE2.6G to share the same system, while
providing >80dB isolation among GSM900, GSM1800, WCDMA2100 and
LTE2.6G system. Main applications for this product include: convention
centers, exhibition halls, airports, underground tunnels and other large
buildings.
With extensive range of passive components, Comba is capable of
providing solutions for almost any combination of frequency bands while
keeping insertion loss to a minimum.

Photo for reference

Technical Specifications
Electrical

Electrical

Frequency Range [MHz]


- GSM900
RX/TX(A):
RX/TX(B):
RX/TX(C):
RX/TX(D):
- GSM1800

- WCDMA,

- LTE2.6G

Insertion Loss [dB]


Isolation [dB]
-Same band
-Cross Band
Return Loss [dB]
PIM [dBc]
(@2x43dBm carriers)

Input Power Rating Per Port [W]


Impedance [ohm]

890-897.5/935-942.5
897.5-907.5/942.5-952.5
907.5-915/952.5-960
885-890/930-935

Mechanical
Dimension LxWxH [mm]

RX/TX(A):
RX/TX(B):
RX/TX(C):
RX/TX(D):
RX/TX(E):
RX/TX(F):

1720.1-1730.1/1815.1-1825.1
1730.1-1740.1/1825.1-1835.1
1740.1-1750.1/1835.1-1845.1
1750.1-1760.1/1845.1-1855.1
1760.1-1770.1/1855.1-1865.1
1770.1-1780.1/1865.1-1875.1

RX/TX(A):
RX/TX(B):
RX/TX(C):
RX/TX(D):

1920.3-1935.1/2110.3-2125.1
1935.1-1949.9/2125.1-2139.9
1950.1-1964.9/2140.1-2154.9
1964.9-1979.7/2154.9-2169.7

RX/TX(A):
RX/TX(B):
RX/TX(C):

150
50

Weight (approx.) [kg]


Number of Output Ports-Combined Duplex

600x400x800
88
2

Number of Input Ports - Duplex


Connector Type Input

17
7/16 Din-Female

Connector Type - Output


Operational Temperature [C]

7/16 Din-Female
0 to +60

Operating Humidity

<95

Mounting
Environmental Class

Floor Stand
Indoor

Shipping Information

2500-2515/2620-2635
2540-2555/2660-2675
2555-2570/2675-2690

(Wooden Crate)
Dimensions, H x W x D [mm]
Weight (approx.) [kg]

860x600x1060
115

6
> 40
> 80
> 18
<-155(REVERSE)

Information contained in this document is subject to confirmation at time of ordering.


Please visit our website at http://www.comba-telecom.com

Issue : 3-1-1
15.08.2011
Page 1

167

POI-TSJ2IDN1HK-TX
Multi Operator Combiner - 6xGSM900 Tx, 6xGSM1800 Tx, 4xUMTS
Tx,3xLTE2.6G Tx/Rx
Features

Permits combining of GSM900, GSM1800, WCDMA2100 and LTE2.6G


services.
Low insertion loss.
High inter-band isolation.
POI downlink unit.

Product Description
The POI-TSJ2IDN1HK-TX is one of a range of compact, low intermodulation,
cellular combiners for cost effective, multi-band in-building combining
systems. This high power combiner is designed to combine GSM900,
GSM1800, WCDMA2100 and LTE2.6G to share the same system, while
providing >80dB isolation among GSM900, GSM1800, WCDMA2100 and
LTE2.6G system. Main applications for this product include: convention
centers, exhibition halls, airports, underground tunnels and other large
buildings.
With extensive range of passive components, Comba is capable of providing
solutions for almost any combination of frequency bands while keeping
insertion loss to a minimum.

Tx Unit Photo for reference

Technical Specifications
Electrical
Frequency Range [MHz]
- GSM900
TX1:
TX2:
TX3:
TX4:
- UMTS850
TX1:
- CDMA2000
TX1:
- PCS1800
TX1:
TX2:
TX3:
TX4:
TX5:
TX6:
- WCDMA2100
TX1:
TX2:
TX3:
TX4:
- LTE2.6G
TX1/RX1:
TX2/RX2:
TX3/RX3:

Electrical

Insertion Loss [dB]

Isolation [dB]
-In band
-Cross Band
Return Loss [dB]

> 40
> 80
> 18

PIM [dBc]@2x43dBm carries

Input Power Rating Per Tx Port [W]


Impedance [ohm]

935.0-942.5
942.5-952.5
952.5-960.0
930-935
877.5-882.5
870-877.5
1815.1-1825.1
1825.1-1835.1
1835.1-1845.1
1845.1-1855.1
1855.1-1865.1
1865.1-1875.1
2110.3-2125.1
2125.1-2139.9
2140.1-2154.9
2154.9-2169.7
2500-2515/2620-2635
2540-2555/2660-2675
2555-2570/2675-2690

150
50

Mechanical
Dimension LxWxH [mm]
Weight (approx.) [kg]
Number of Output Ports-Combined
Simplex
Number of Input Ports 2G&3G Simplex
LTE2.6G Duplex
Number of Monitors Ports 306dB

600x400x650
60
2TX
16TX
3TX/Rx
2TX

Connector Type Input

7/16 Din-Female

Connector Type - Output


Connector Type - Monitors ports

7/16 Din-Female
N-Female

Operational Temperature [C]

-10 to +65

Operating Humidity
Mounting

<95
Floor Stand

Environmental Class

Indoor

Shipping Information
(Wooden Crate)
Dimensions, H x W x D [mm] TX/RX
Weight (approx.) [kg]

750x490x960
85

<-155(REVERSE)

Information contained in this document is subject to confirmation at time of ordering.


Please visit our website at http://www.comba-telecom.com

Issue : May.2012
2-1-0
Page 1

168

POI-TSJ2IDN1HK-RX
Multi Operator Combiner - 6xGSM900 Rx, 6xGSM1800 Rx,4xUMTS Rx,
3xLTE2.6G Tx/RX
Features

Permits combining of GSM900, GSM1800, WCDMA2100 and LTE2.6G


services.
Low insertion loss.
High inter-band isolation.
POI uplink unit

Product Description
The POI-TSJ2IDN1HK-RX is one of a range of compact, low intermodulation,
cellular combiners for cost effective, multi-band in-building combining
systems. This high power combiner is designed to combine GSM900,
GSM1800, WCDMA2100 and LTE2.6G to share the same system, while
providing >80dB isolation among GSM900, GSM1800, WCDMA2100 and
LTE2.6G system. Main applications for this product include: convention
centers, exhibition halls, airports, underground tunnels and other large
buildings.
With extensive range of passive components, Comba is capable of providing
solutions for almost any combination of frequency bands while keeping
insertion loss to a minimum.

Rx Unit Photo for reference

Technical Specifications
Electrical
Frequency Range [MHz]
- GSM900
RX1:
RX2:
RX3:
RX4:
- UMTS850
RX1:
- CDMA2000
RX1:
- GSM1800
RX1:
RX2:
RX3:
RX4:
RX5:
RX6:
- WCDMA2100
RX1:
RX2:
RX3:
RX4:
- LTE2.6G
TX1/RX1:
TX2/RX2:
TX3/RX3:

Electrical
Input Power Rating Per [W]

150

890.0-897.5
897.5-907.5
907.5-915.0
885-890
832.5-837.5
825.0-832.5
1720.1-1730.1
1730.1-1740.1
1740.1-1750.1
1750.1-1760.1
1760.1-1770.1
1770.1-1780.1
1920.3-1935.1
1935.1-1949.9
1950.1-1964.9
1964.9-1979.7
2500-2515/2620-2635
2540-2555/2660-2675
2555-2570/2675-2690

Impedance [ohm]

50

Insertion Loss [dB]

(Wooden Crate)

Isolation [dB]
-In band
-Cross Band
Return Loss [dB]

> 40
> 80
> 18

Mechanical
Dimension LxWxH [mm]

600x400x650

Weight (approx.) [kg]


Number of Output Ports-Combined Simplex
Number of Input Ports 2G&3G Simplex
LTE2.6G Duplex
Number of Monitors Ports 306dB

60
2RX
16RX
3TX/Rx
2RX

Connector Type Input

7/16 Din-Female

Connector Type - Output


Connector Type - Monitors ports

7/16 Din-Female
N-Female

Operational Temperature [C]

-10 to +65

Operating Humidity
Mounting

<95
Floor Stand

Environmental Class

Indoor

Shipping Information
Dimensions, H x W x D [mm] TX/RX
Weight (approx.) [kg]

Information contained in this document is subject to confirmation at time of ordering.


Please visit our website at http://www.comba-telecom.com

750x490x960
85

Issue : 7th May.2012


2-1-0
Page 1

169

U Clamp

0 2 4
6

8
10 12

Show above is the


downtilt angle mark of
SJA-B-12R (12)

Step 4: Tighten "A" to lock antenna in


position (25Nm).

Step 4: Adjust downtilt mounting


bracket to achieve required
downtilt.

With Mechanical Downtilt

Step 3: Mount the antenna


to pole and tighten
M10 bolts (25Nm).

50 - 110
Lock Nut

Clamp

Clamp

Lock Nut

Step 2: Attach mounting


brackets to antenna.
Secure it with M8 bolts.

Step 3: Mount the antenna to pole


and tighten M10 bolts
(25Nm).

50 - 110

Without Mechanical Downtilt

Step 2: Attach mounting


brackets to antenna.
Secure it with M8 bolts.

Downtilt Mounting Bracket

Mounting Bracket

Step 1: Identify and assemble


mounting brackets. Secure
the U Clamp with M8 bolts.

U Clamp

Step 1: Identify and assemble


mounting brackets. Secure
the U Clamp with M8 bolts.

Installation Instruction SJA-B-12R QD 1-2-1

Step 5: Tighten "A" to lock antenna


in position (25Nm).

Installation Preparation:

l Check each package against packing list.


l Observe safe working at heights.
l Ensure lightning protection is applied.
l Annual maintenance is recommended to antenna system.

Date:

Packing List
Qty
Description
Antenna
Kit
of Parts
SJA-B-12R (00) 1 SJA-B-12R (xx)
Downtilt Mounting Bracket
0
1
Mounting Bracket
2
1
U Clamp
2
2
Clamp
2
2
Hex Bolt (M10 x 150)
4
4
Nut (M10)
8
8
Plain Washer (M10)
4
4
Hex Bolt (M8 x 25)
8
8
Nut (M8)
8
8
Plain Washer (M8)
8
8
Spring Washer (M8)
8
8
Mechanical Downtilt Range
Mounting Bracket
Downtilt Range
L (mm)
SJA-B-12R (00)
0
SJA-B-12R (08)
1900
0~8
SJA-B-12R (12)
1450
0~12
1088
SJA-B-12R (16)
0~16
SJA-B-12R (17)
1219
0~17
SJA-B-12R (28)
662
0~28
558
0~32
SJA-B-12R (32)
Antenna was inward tested, which complying with Comba Enterprise
Standard (Q/GZ JXTX 1-2004: QB440100).

Test Engineer:

Enhancing Communications

Corporate Headquarters

India Headquarters

Comba Telecom Systems Holdings Ltd.

Comba Telecom India (P) Ltd.,

611 East Wing, No.8 Science Park West Avenue,


Hong Kong Science Park,
Tai Po
Hong Kong

E-172, Greater Kailash Part I,


New Delhi -110048.
India

Tel: +852 2636 6861


Fax: +852 2637 0966

Tel: +91 11 4173 9997 / 8


Fax: +91 11 4173 9996

China Headquarters

North America Headquarters

Comba Telecom Systems (China) Ltd.

Comba Telecom Inc.

No. 10 Shenzhou Road,


Guangzhou Science City,
Guangzhou
China

235 Charcot Ave,


San Jose,
CA 95131
USA

Tel: +86 20 2839 0000


Fax: +86 20 2839 0136

Tel: +1 408 526 0180


Fax: +1 408 526 0181

Europe Headquarters

CALA Headquarters

Comba Telecom Systems AB

Comba Telecom Ltda

Gustavslundsvagen 147,
SE-167 51 Bromma,
Stockholm
Sweden

Rua Helena, 235 Conj 91 - Edifcio Atrium II,


04552-050 Vila Olmpia,
Sao Paulo
BRAZIL

Tel: +46 8 253 870


Fax: +46 8 253 871

Tel: +55 11 3509 4800


Fax: +55 11 3509 4833

Middle East Headquarters


Comba Telecom Ltd.
Unit 112, Building 5, Gold and Diamond Park, AI Qouz,
Dubai,
U.A.E.
Tel: +971 (0) 4 346 7277
Fax: +971 (0) 4 346 7288

)RUORFDORIFHGHWDLOVSOHDVHYLVLWWKH&RPEDZHEVLWHRUFRQWDFWWKHUHJLRQDOKHDGTXDrWHUV
Website: www.comba-telecom.com
Email: comba@comba-telecom.com

Copyright 2012 Comba Telecom Ltd.

You might also like