Professional Documents
Culture Documents
Flexibility
The compatibility with the VSN300
Wifi Logger Card (optional) within the
integrated expansion slot, assures an
advanced and cost effective solution
for the control and monitoring of the
plant, without the need of further
components
Predisposed stand alone option,
which offers the advantage of a
backup for the AC output (max 1500
W) to power a load in case of a
network blackout
Highlights
Single-phase output
Transformerless topology
Each inverter is set to specific grid
codes which can be selected in the
field
Wide input range and high efficiency
values
High speed and precise MPPT
algorithm enables real-time power
tracking and improved energy
harvesting
Plug and Play connection for DC, AC
and communication side
Additional highlights
Integrated DC switch, in compliance
with international standards (-S
version)
Natural convection cooling for
maximum reliability
Outdoor enclosure for unrestricted
use under any environmental
conditions
(preliminary)
Type code
Input side
Absolute maximum DC input voltage (Vmax,abs)
Start-up DC input voltage (V start)
Operating DC input voltage range (Vdcmin...V dcmax)
Rated DC input voltage (V dcr)
Rated DC input power (Pdcr)
Number of independent MPPT
MPPT input DC voltage range (VMPPTmin ... VMPPTmax) at Pacr
Maximum DC input current (Idcmax)
Number of DC inputs pairs
DC connection type
Input protection
Reverse polarity protection
Input over voltage protection - varistor
Photovoltaic array isolation control
DC switch rating (version with DC switch)
Output side
AC Grid connection type
Rated AC power (Pacr @cos=1 )
Maximum AC output power (Pacmax @cos=1)
Maximum apparent power (Smax)
Rated AC grid voltage (Vac,r)
AC voltage range
Maximum AC output current (Iac,max)
Contributory fault current
Rated output frequency (fr)
Output frequency range (fmin...fmax)
Nominal power factor and adjustable range
Total current harmonic distortion
AC connection type
Output protection
Anti-islanding protection
Maximum external AC overcurrent protection
Output overvoltage protection - varistor
UNO-2.0-TL-OUTD
UNO-3.0-TL-OUTD
UNO-3.6-TL-OUTD
600 V
100...300 V (default 150 V)
0.7xVstart...580 V (min 80 V)
400 V
2200 W
3200 W
UNO-4.2-TL-OUTD
850 V
380 V
350...820 V
500 V
3900 W
600 V
4500 W
1
180...500 V
12.5 A
200...500 V
16 A
380700 V
12.5 A
1
MultiContact MC4
Yes, from limited current source
Yes
According to local standard
600 V, 25 A
1000 V, 16 A
Single-phase
2000 W
2000 W
2000 VA
3000 W
3000 W
3000 VA
230 V
180...264 V
10 A
12 A
15 A
17 A
3600 W
3600 W
3600 VA
4200 W
4200 W
4200 VA
16 A
18 A
20 A
22 A
1)
50 Hz / 60 Hz
47...53 Hz / 5763 Hz 2)
> 0.995, adj. 0.8 with max Smax
<3%
Panel female connector
16 A
25 A
IN1
IN1
IN1
Standard version
MPPT 1*
(DC/DC)
+
IN1
Inverter
(DC/AC)
Bulk caps*
Grid parallel
relay
Line
filter
IN1
-S version
PE
Residual current
detection
RS485
+ T/R
- T/R
RTN
DC/AC
DSP
contr.
Remote Control
Micro
Safety
+R
-R
Alarm
N.C
N.O
C
Stand alone
+ SA
- SA
Control circuit
(* not present for 3.6/4.2 versions)
(preliminary)
Type code
Operating performance
Maximum efficiency (max)
Weighted efficiency (EURO/CEC)
Feed in power threshold
Night consumption
Communication
Remote monitoring
Wireless local monitoring
User interface
Environmental
Ambient temperature range
Relative humidity
Maximum operating altitude without derating
Physical
Environmental protection rating
Cooling
Dimension (H x W x D)
Weight
Mounting system
Safety
Isolation level
Marking
Safety and EMC standard
Grid standard (check your sales channel for availability)
Available products variants
Standard
With DC switch
UNO-2.0-TL-OUTD
UNO-3.0-TL-OUTD
UNO-3.6-TL-OUTD
97.30%
96.00% / 10 W
UNO-4.2-TL-OUTD
98.40%
97.5% / 8W
< 0.1 W
VSN300 Wifi Logger Card (opt.)
VSN300 Wifi Logger Card (opt.)
Display (2x16 line LCD)
-20...+60C, with derating >45C
0100% condensing
2000 m / 6560 ft
IP65
Natural
553 x 418 x 175 mm
12 kg
Wall bracket
Transformerless
CE
IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3
CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, VFR2014
UNO-2.0-TL-OUTD
UNO-2.0-TL-OUTD-S
1)
The AC voltage range may vary depending on specific country grid standard
2)
The Frequency range may vary depending on specific country grid standard
UNO-3.0-TL-OUTD
UNO-3.0-TL-OUTD-S
UNO-3.6-TL-OUTD
UNO-3.6-TL-OUTD-S
UNO-4.2-TL-OUTD
UNO-4.2-TL-OUTD-S
Remark. Features not specifically listed in the present data sheet are not included in the product
99
99
98
98
97
97
96
96
95
95
94
94
93
93
Efficiency [%]
92
91
90
92
91
90
89
89
88
200 Vdc
88
380 Vdc
87
400 Vdc
87
600 Vdc
86
600 Vdc
86
700 Vdc
85
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
85
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Efficiency [%]