You are on page 1of 34

A PRESENTATION ON

CASE STUDY OF
TAIPEI 101
THE WORLDS 3RD TALLEST BUILDING

Civil Engineering 2nd Semester (M.Tech Structure)


Prepared By
Bhavin Dhondhe
Akash Kaswala
Junead Nathani
Vatsal Parmar
Kavin Patel
Manav Patel
Ankit Upadyay
Guided By
Prof. Nirpex Patel
(M.E. in CASAD)
CSPIT

[15PGCL009]
[15PGCL014]
[15PGCL018]
[15PGCL022]
[15PGCL025]
[15PGCL027]
[15PGCL037]

Prof. Neha Chauhan


(M.E. in Structure)
CSPIT

INTRODUCTION
STRUCTURAL DESIGN
SPECIAL MEASURES
SPECIAL MATERIAL

REFERENCES

INTRODUCTION
STRUCTURAL DESIGN
SPECIAL MEASURES
SPECIAL MATERIAL

REFERENCES

INTRODUCTION

Mega structural system for vertical and lateral loads, including

typhoon and strong earthquake

550 bored piles

High strength and ductility structural steel with RBS

Columns infilled with high performance concrete (10,000psi)

Tuned mass damper to reduce wind vibrations - Nonlinear time


history analyses

INTRODUCTION
STRUCTURAL DESIGN
SPECIAL MEASURES
SPECIAL MATERIAL

REFERENCES

INTRODUCTION
STRUCTURAL DESIGN
SPECIAL MEASURES
SPECIAL MATERIAL

REFERENCES

STRUCTURAL DESIGN

GRAVITY LOAD
Gravity loads are carried vertically by a variety of columns.
Within the core, sixteen columns are located at the crossing points
of four lines of bracing in each direction. The columns are box
sections constructed of steel plates, filled with concrete for added
strength as well as stiffness at the 62nd floor and below.
On the perimeter, up to the 26th floor, each of the four building
faces has two super-columns, two sub-supercolumns, and two
corner columns.
Above the 26th floor has the two super-columns continue
upward.

STRUCTURAL DESIGN

LATERAL LOAD

Lateral forces are resisted through a combination of braced


frames in the core, outriggers from core to perimeter
supercolumns and moment resisting frames in the perimeter and

other selected locations.

Wind Dampers are used to reduce lateral vibrations due to wind.

STRUCTURAL DESIGN

[Fig. 1. This typical setback floor plan shows sawtooth corners.]

STRUCTURAL DESIGN

[Fig. 2. Supercolumns are filled with


high-strength concrete for added
stiffeness as shown shaded here.]

[Fig. 3. Elevation of a perimeter


moment frame line with belt
trusses.]

STRUCTURAL DESIGN

[Fig. 4. The 3-D computer model for Taipei 101 .]

STRUCTURAL DESIGN

[Fig. 5. Foundation plan.]

STRUCTURAL DESIGN

[Fig. 6. Pile foundation.]

STRUCTURAL DESIGN

[Fig. 7. Typical floor framing plan Lower Story.]

STRUCTURAL DESIGN

[Fig. 8. Typical floor framing plan upper story.]

STRUCTURAL DESIGN

2X4=8 outriggers,

1 vertical belt truss,

1 horizontal belt truss,


SMRF

[Fig. 9. Mechanical floor.]

[Fig. 10(a). Elevation.]

[Fig. 10(b). Elevation.]

STRUCTURAL DESIGN

[Fig. 10(c). Elevation & Sections.]

INTRODUCTION
STRUCTURAL DESIGN
SPECIAL MEASURES
SPECIAL MATERIAL

REFERENCES

INTRODUCTION
STRUCTURAL DESIGN
SPECIAL MEASURES
SPECIAL MATERIAL

REFERENCES

SPECIAL MEASURES

SPECIAL MEASURES TO RESIST WIND AND SEISMIC FORCES:

High Strength and High Ductility Steel Plates SM570M

High Strength and High Performance Concrete

Infilling Columns

- 10,000 psi

High Ductility Beam-Column Connection Reduced Beam Sections

Tuned Mass Damper - Tower

Smaller Tuned Mass Dampers Pinnacle

SPECIAL MEASURES

[Fig. 11. Supercolumn box plan [Fig. 12. Position of Tuned Mass [Fig. 13. The pendulum of the main
details show stiffeners.]
Damper.]
Tuned Mass Damper.]

SPECIAL MEASURES

[Fig.14. A supercolumn box just below


its field splice location.]

[Fig. 15. Concrete fill is reinforced by


vertical bars threaded through
diaphragm holes.]

SPECIAL MEASURES

[Fig. 16. Taipei 101 Tuned Mass Damper.]

INTRODUCTION
STRUCTURAL DESIGN
SPECIAL MEASURES
SPECIAL MATERIAL

REFERENCES

INTRODUCTION
STRUCTURAL DESIGN
SPECIAL MEASURES
SPECIAL MATERIAL

REFERENCES

SPECIAL MATERIAL

HIGH PERFORMANCE STEEL PLATES - SM570M

Used for tower columns, girders & braces

High strength : 60 ksiFy74 ksi

High ductility : Yield ratio80% For girders & braces

High weldability : Ceq 0.44 % ( t 40 mm ) 0.47 % ( t


40 mm )

Through-thickness ductility

Impact absorption energy

SPECIAL MATERIAL

10000 psi HIGH PERFORMANCE CONCRETE

Design strength : 10000psi @ 90 days

High flowability: slump - 25020mm slump flow - 60020mm

5% maximum air bubble underneath diaphragm plate

Autogenous shrinkage 30010-6 m/m @ 90 days

INTRODUCTION
STRUCTURAL DESIGN
SPECIAL MEASURES
SPECIAL MATERIAL

REFERENCES

INTRODUCTION
STRUCTURAL DESIGN
SPECIAL MEASURES
SPECIAL MATERIAL

REFERENCES

REFERENCES

You might also like