230

4500

300300
25

R1

Q
3- 8T

Coping
Q
3- 8T

OUTSIDE

Q
3- 8T

Coping
Q
3- 8T

4500

300

300

300

300

Stirrups
Q @ 180 c/c
8T

E.G.L.

300 tk. Block Masonry


(1:6 Mortar)

INSIDE

Stirrups
Q @ 180 c/c
8T

300 tk. Block Masonry


(1:6 Mortar)

300

14700

4500

PLAN

75

Stirrups
Q @ 180 c/c
8T

300 tk. Block Masonry


(1:6 Mortar)

Stirrups
Q @ 180 c/c
8T

25 mm Expansion Joint @ every 14.7mt.

300

300

230
300 tk. Block Masonry
(1:6 Mortar)

600

450

P.C.C 1:3:6
750

230

300

Q
3- 8T

Q
3- 8T

Coping

Q
3- 8T

E.G.L.

Coping
Q
3- 8T

300

450

600
P.C.C 1:3:6

300

Typical Section For Compound Wall (Eccentric)

300

C1

75

300

Q @ 150 c/c
Ties 8 T

600

Vert. r/f 6 - 10 TQ

600

4500

100 min. 'L'


300

Q
4 - 12 T

600
Q
3 - 10 T

E.G.L.

4500

300

FO

Section:- S-S

Q @ 150 c/c
8T

Q
4 - 12 T

O
TI
C
U
R
ST
N

Q
4 - 12 T

Q @ 150 c/c
8T

Q
3 - 10 T

O
C

Section:- R-R

300

Q
3 - 10 T

25 mm Expansion Joint @ every 14.7mt.

1 C1

300 300
25

Column C1 300 x 230 (M25)

Q @ 150 c/c
Ties 8 T

E.G.L.

Vert. r/f 6 - 10 TQ
600
Q
3 - 10 T

Column C1 300 x 230 (M25)

300

Vert. r/f 6 - 10 TQ

Q @ 150 c/c
Ties 8 T

300

Section:- C-C

300

Q
4 - 12 T

300

25 mm Expansion Joint
@ every 14.7mt.

Coping

Q
3 - 10 T

Q
3 - 10 T

230
Column C1 300 x 230 (M25)

75

Coping

100 min. 'L'


300

300

Section:- B-B

300

300

300

300
750

1830
Up to good yellow consolidated soil
1500 min.

125
125

125
125

Section:- A-A

200

400
75

1830
Up to good yellow consolidated soil
1500 min.
75 200
200

OWNER:

ARCHITECT:

ALCHEMY REAL ESTATE

Turf Es tate 9&10, Off Dr. E. Moses Road, Shakti Mill Compound
Lane, Mahalakshimi (w), Mumbai-400011. Tel.- 4933535 / 46 / 52.

CONSULTANT :

Aashutosh. A. Desai

201 , Spentha Complex , Opp.Vanijya Bhavan,

Race Course Circle (E),Vadodara.

E - Mail :- aashutoshdesai@gmail.com

Tele Fax :- 0265 - 2340032

KEY PLAN

PROJECT MANAGEMENT CONSULTANTS

DTZ INTERNATIONAL PROPERTY ADVISORS PVT LTD,

Level 3, Featherlite Vista, # 8, 1st Main road,


Vasanthnagar, Bangalore - 560 052

Ph.-080-22348020
E-mail : entaskblr@entask.co.in
Website : www.entask.co.in

ENTASK CONSULTANCY SERVICES PVT. LTD

MEP CONSULTANTS

SPECIFIC NOTES:

1. All R.C.C. works should be carried out as per I.S. 456-2000


2. All steel Structrual works should be done as per I.S. 800-1984
Q indicates torsteel indicates Mild Steel.
3. T
4. Structural and Architectural drawings should be followed in relation to each other &
any Ambiguity if found should be reported in writing before execution.
5. Structural Engineer is not responsible for Centering, Curing,
Fabrication, Welding, Misunderstanding of drawings & Quality of Materials.
6. This drawing is property of A.A. DESAI & should not be used without permission.
7. Follow this drg. with respect to General Instruction Sheet
(Drg No. AB_S09_G_001).
8. All Concreting to be done using Concrete Machine mixer & Vibrator Only.
9. All CenterLine Dimensions as per Architects dgrs./details.
10.M20 = 1:2:3 & M25 = 1:1:2 Ratio Using Grade 53 Cement of Approved
Brand.
11. R/F Cover For Column -40, Coping - 12.5.
12. Steel Denoted as Q
T Conforming to IS:1786 Fe 500 Grade.
13. Grade of Concrete M20 Unless Otherwise Specified.
14.This Drawing is Part of a set of Drawing for This Project and shall not be
Considered valid unless it is accompanied by the complete set of Drawings
15. All Dimensions are in mm. Unless Mentioned Otherwise.
16. For Cutout / Spout in Retaining Wall, Slab etc follow Standard Details Sheet
(Drg No.AB_S09_G_002).
15.Structure Engineer is not responsible for any Structural Problem/Failure arising due
to any unauthorised Drilling, Cutting, Breaking etc in any R.C.C Member for any
purpose whatsoever (AC Piping, Electrical Plumbing etc.)
18. The site execution based on these structure drawings to be carried out on availing
building permission from concerned Authority and as per approved Plan only.
These shall be sole responsibility of the Client/Developer. The Structure Engineer is
not Directly/Indirectly responsible for any legal deviation what so ever.
14. SBC Considered is 16.0 T/m @ Depth of 1.5mt For Compound wall as per
Geotechnical Investigation Report by M/s. ICON CADSOFT AND SURVEYORS INDIA
PVT. LTD._Addendum Dated 20th August 2015.

REVISION

DATE

PRINT ISSUED (SOFT COPY)

TO WHOM
ISSUED
Arch.
Arch.
Arch.

DATE

TO WHOM
ISSUED

PRINT ISSUED (HARD COPY)

TO WHOM
ISSUED

A.A.Desai

Jalpa

A.A.Desai

21-08-15

A.A.D. 2013 M16

ALCHEMY SAMSARA

BANGALORE

TO WHOM
ISSUED

1. 14-09-15 Typical Section For Compound Wall (Eccentric) Added.