Reference Documents and Drawings for ETAP

Sr.

Location

Rev.

Status

Folder # 5

AD197-564-E-40702

Overall Electrical Block Diagram LQM & Buildings

Advance Copy

Folder # 5

Reference No.

AD197-564-G-04558

Electrical Load List for LQM and Buildings (Normal Power - HVAC, Power, Lighting)

Description

Official Issue

Folder # 5

AD197-564-G-04559

Electrical Load List for LQM and Buildings (Emergency Power - HVAC, Power, Lighting)

Official Issue

Folder # 5

AD197-564-E-40792

SLD for HVAC MCC (Normal) - LQM : 564-MCC-0003

Advance Copy

Folder # 5

AD197-564-E-40793

SLD for HVAC MCC (Emergency) - LQM : 564-SWGRE-0003

Advance Copy

Folder # 5

AD197-564-E-40794

SLD for HVAC MCC - Electrical Substation SS-1 : 564-MCC-0001

Advance Copy

Folder # 5

AD197-564-E-40795

SLD for HVAC MCC - Workshop : 564-MCC-0002

Advance Copy

10

Folder # 5

AD197-564-E-40796

SLD for Main Power Distribution Board-1 (Normal) : 564-DB-0011

Advance Copy

11

Folder # 5

AD197-564-E-40797

SLD for Main Power Distribution Board-2 (Normal) : 564-DB-0012

Advance Copy

12

Folder # 5

AD197-564-E-40798

SLD for Main Power Distribution Board (Emergency) : 564-DBE-0011

Advance Copy

13

Folder # 5

AD197-564-E-40799

SLD for HVAC Power Distribution Boards (Duct Heater, FCUs etc.)

Official Issue

14

Folder # 5

AD197-564-E-40800

SLD for Lighting Distribution Board for LQM and Buildings

Official Issue

15

Folder # 5

AD197-564-E-40801

SLD for Small Power Distribution Board for LQM and Buildings

Official Issue

16

Folder # 2

Circuit Breaker and Protection Relay Catalogues

Provided

17

Folder # 2

Circuit Breaker Input Data Comparison Sheet (IDE)

Pending

18

Folder # 2

Relay Input Data Sheet (IDE)

Pending

19

Folder # 3

Motor Input Data Evaluation Sheet (Overall)_7April2016

Provided

20

Folder # 3

Motor Data: Air-Cooled Chiller

Provided

21

Folder # 3

1) Air-Cooled Chillers Schedule

Provided

22

Folder # 3

2) Air-Cooled Chillers Selection

Provided

23

Folder # 3

3) Chiller Mechanical Layout

Provided

24

Folder # 3

4) Compressor motor RC2-catalogue

Provided

25

Folder # 3

5) Compressor Motor Attributes RC2-830B

Provided

26

Folder # 3

6) Compressor Motor Attributes RC2-930B

Provided

27

Folder # 3

7) Chiller Control Panel Technical Data

Provided

28

Folder # 3

Provided

29

Folder # 3

1) Chilled Water Pump Schedule

Provided

30

Folder # 3

2) Chilled Water Pump motor datasheet

Provided

31

Folder # 3

3) Motor GA Drawing

Provided

32

Folder # 3

4) Motor Catalogue

Provided

33

Folder # 3

Provided

34

Folder # 3

1) AHU&FAHU Schedule

Provided

35

Folder # 3

2) Safe Area Motor Datasheets

Provided

36

Folder # 3

3) Exd Area Motor Datasheets

Provided

37

Folder # 3

4) Motors for Explosive atmospheres Catalogue

Provided

38

Folder # 3

Provided

39

Folder # 3

1) HVAC Fans Schedule

Provided

40

Folder # 3

2) Motor Datasheets

Provided

42

Folder # 1

43

Folder # 1

AD197-SCHE-40805

44

Folder # 4

HVAC MCC Operating Philosophy

Provided

45

Folder # 6

AD197-564-E-40861

Technical Drawings for HVAC MCC (Normal) - LQM : 564-MCC-0003

To be Updated

46

Folder # 6

AD197-564-E-40862

Technical Drawings for HVAC MCC (Emergency) - LQM : 564-SWGRE-0003

To be Updated

47

Folder # 6

AD197-564-E-40867

Technical Drawings for HVAC MCC - ELECTRICAL Substation SS-1 : 564-MCC-0001

To be Updated

48

Folder # 6

AD197-564-E-40866

Technical Drawings for HVAC MCC - WORKSHOP : 564-MCC-0002

To be Updated

49

Folder # 6

AD197-564-E-40863

Technical Drawings for Main Power Distribution Board-1 (Normal) : 564-DB-0011

To be Updated

50

Folder # 6

AD197-564-E-40864

Technical Drawings for Main Power Distribution Board-2 (Normal) : 564-DB-0012

To be Updated

51

Folder # 6

AD197-564-E-40865

Technical Drawings for Main Power Distribution Board (Emergency) : 564-DBE-0011

To be Updated

52

Folder # 7

PMS Architecture for MCC/Panels

To be Updated

Motor Data: Chilled Water Pumps

Motor Data: AHU & FAHU

Motor Data: HVAC Extract Fans

Cable Data sheet

Provided

Electrical Cable Schedule for HVAC Systems - LQM and Buildings

Advance Copy

Data to be furnished by the Client for carrying out this


study shall generally cover the following.

Stage 1

FOR ETAP BASED STUDIES


1

Electrical key and detailed protection single line diagram of plant.

Plant operating philosophy with list of plant electrical NO points.

Load List as per Load List Input data evaluation (IDE) sheet.
Normal and emergency load list
Load list differentiating essential and non-essential loads.
List of Non linear loads their location and Harmonic content of
each of them.

Details of system neutral earthing at each plant input voltage


levels, whether solid or through NER with details of magnitude of
NER limiting ampere.

Maximum and minimum generation level.

Generator Data
Prime mover type, governor type expected make and model and
whether static or mechanical or digital.
Exciter type expected make and model and whether static or
mechanical or digital.
Typical exciter and governor control system block diagram with
transfer function gain and time constant parameters as per IEEE
standards.
Data as per generator IDE

Generator open circuit characteristics to assess saturation effects.

Generator overload withstand characteristic

Generator voltage and current harmonics for all generators when


operating in parallel under different loading conditions
Coil pitch of generators
Turbine generator load application & load rejection, transient
voltage and speed response as per supplier estimates, expectations
& if necessary test reports.

Transformer Data
Transformer Data as per Transformer IDE

Cable Data as per Cable IDE

Motor Data
Vendors technical data sheet and/or name plate ratings with
torque-speed, current-speed and power factor-speed of all large HV
motors and their driven equipment load torque characteristics,
including combined driving and driven equipment inertias.

Each Large Plant Motor technical data such as


a) Motor name plate ratings
b) Motor power factor, slip, efficiency at 100%, 75% and 50%
loading
c) Motor starting or locked rotor current (LRC)
d) Motor locked rotor torque (LRT) and peak break down torque
e) Motor starting time. (@ 80%, 100 % & 110% voltage)
f) Motor test certificates if available
g) Motor torque v/s slip curve
h) Motor load torque V/s slip curve under normal operation & during
starting
i) Motor starting device details (if Rotor resistor then value & steps
with time)

j) Motor stator hot withstand time versus current


k) Motor stator cold withstand time versus current
l) Motor locked rotor hot withstand time versus current
m) Motor locked rotor cold withstand time versus current
n) Motor no. of cold & hot starts permitted
o) Motor Thermal heating time constant & Cooling time constant
p) Motor negative sequence current (I22t) withstand time.
Data as per Motor & Motor Load IDE

10

Protection Device Data


Feeder wise Relay/Release/fuse type, make, PMS, TMS, Curve type
data.
Detailed technical vendor setting catalogues of each type of relay,
release and fuse.
Current Transformer Data such as CT ratio, CT resistance, knee
point voltage and magnetizing characteristics.
Voltage Transformer data
Relay Data as per IDE
Bus Data as per IDE

11

Circuit Breaker Data


Circuit Breaker Data as per IDE
Load shedding philosophy with loads identified to be shed.

Stage 2

Stage 3

Annexure-II

INPUT DATA EVALUATION REPORT

TRANSFORMER INPUT DATA EVALUATION SHEET


GENERAL
Sr No.

Transformer ID

SA-TF/OTI/EA/SD0.078/IDE-EQP-TX R0

From Bus ID

RATINGS
To Bus ID

MVA
(ONAN/ONAF)

BASE MVA

Prim. kV

Sec. kV

%TAP SETTINGS
% Z (Z0 & Z1)

Page 6 of 7

X/R

Vector
Group

Grounding Type

TAP TYPE
FIXED / OLTC

TAP RANGE

% TAP STEPS

RS120810

Annexure-II

INPUT DATA EVALUATION REPORT

TRANSFORMER INPUT DATA EVALUATION SHEET


GENERAL
Sr No.

Bus ID

RATINGS
Make

SA-TF/OTI/EA/SD0.078/IDE-EQP-TX R0

Cont. Amp

Peak Fault
Current Withstand
capacity

Data for Arc Flash Analysis


Thermal Fault
Rating

Page 7 of 7

Withstand
time

Bus Type

Gap between
Distance X factor
Conductors/buses

Working
Distance

RS120810