Peppers Cable Glands Limited specialise in the manufacture of
cable glands for use in the hazardous locations found within Oil,
Gas and Petrochemical installations.
At Peppers we have manufactured and marketed our own range
of cable glands for over 60 years and have an enviable reputation
for delivering quality products along with the highest possible
levels of customer service and flexibility.
With the help of our distribution network, we aim to provide the
global market with regular quantities of glands either from stock
or within a matter of days, and project quantities within just a
few weeks.
Typical users of Peppers products include Oil and Gas operators,
petrochemical and pharmaceutical companies, engineering
contractors and hazardous area equipment manufacturers worldwide.
Peppers is part of the Currie & Warner Group, one of Europes
leading turned part operations, again with a global customer
base.
To ensure consistent product quality Peppers work within a
Quality Assurance System that is approved to ISO 9001:2000.
Due to Peppers commitment to an on-going programme of
product development you may find products available which are
not yet described in our catalogues. Some may also be slightly
different from current descriptions. Any differences which effect
safety will result in the relevant catalogue page being re-issued.
The best place to check for up to date information is our website

http://www.cableglands.com

Cable Gland Selection Guide


Gland Type

Outer Seal

Inner Seal

Lead Option

Armour Clamp

Certification

IP Rating

Page No.

ATEX / CSA / GOST / IECEx / NEPSI Approved Glands Featuring Elastomeric Seals

CR-1

Universal

Crocklock

1.1.0

E1WF

Deluge, IP66,68,
Exd/Exe
NEMA 4X
Exd/Exe

IP66,
67
(CSA Pending)

1.2.0

CWLE

Exe

(CSA Pending)

1.3.0

A2LF

A2LDSF

x2

A2LC*F-Conduit

RG22E

IP66, 67

Deluge, IP66,68,
Exd/Exe
NEMA 4X
Deluge, IP66,68,
Exd/Exe
NEMA 4X
Deluge, IP66,68,
Exd/Exe
NEMA 4X
Exe

IP66, 68
(ATEX Only)

2.1.0
2.2.0
2.3.0
2.4.0

ATEX / GOST / IECEx / NEPSI Approved Glands Featuring Elastomeric Seals For Flat Cable

E8XF

Flat Cable

Flat Cable

Exd/Exe
Braid

IP66

3.1.0

A8F

Flat Cable

Exd/Exe

IP68

3.2.0

ATEX / CSA / GOST / IECEx / NEPSI Approved Barrier Glands


CR-C

Compound

Universal

Crocklock

CR-X

Compound

Compound

CR-U

Compound

CR-S
(Stopper Box)

Compound

Deluge, IP66,68,
Exd
NEMA 4X
Deluge, IP66,68,
Exd
NEMA 4X
Deluge, IP66,68,
Exd
NEMA 4X
Exd
Deluge, IP66,68,
NEMA 4X

4.1.0
4.2.0
4.2.1
4.3.0

UL Approved Barrier Glands


UL-C

Compound

UL-C

Compound

Compound

UL-C

Compound

Class I
Universal
Deluge, IP66,68,

Div 1 ABCD
Crocklock
NEMA 4X
Deluge, IP66,68,
Class I


NEMA 4X
Div 2 ABCD
Deluge, IP66,68,
Class I


NEMA 4X
Div 2 ABCD

4.4.0
4.5.0
4.5.1

Industrial Glands Meeting the Requirements of EN50262


BW

Industrial

(BS6121)

IP30

5.1.0

CWL

Industrial

IP66

5.2.0

E1W

Industrial

IP67

5.3.0

A2L

Industrial

IP66, 68

5.4.0

ACCESSORIES

AR

ARN

IA

SPMH

SPMHN

SPA/SPB

ACDPE

GENERAL

Adaptors & Reducers


Nylon Adaptors & Reducers
Insulated Adaptors
Mushroom Head Stopping Plugs
Nylon Mushroom Head Stopping Plugs
Type A & Type B Stopping Plugs
Breather Drain

IP66,68,
Exd/Exe
NEMA 4X 6P
IP66,68,
Exe
NEMA 4X 6P
IP66,68,
Exd
NEMA 3
IP66,68,
Exd/Exe
NEMA 4X 6P
IP66,68,
Exe
NEMA 4X 6P
IP66,68,
Exd
NEMA 3
IP66,68,
Exe
NEMA 4X

Locknuts, Earth Tags etc.

7.1.1
7.1.2
7.1.3
7.2.1
7.2.2
7.2.3
7.3.1
7.4.1

REFERENCE DATA

Entry Thread reference tables

Ingress Protection

II

Gland Weight Data

II

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Cable Gland:- Type CR-1 featuring CROCLOCK


Part of our ATEX Gland Range
2006 Catalogue Page 1.1.0
Croclock CR-1 type glands provide a seal on the inner sheath, a seal on the outer sheath and a universal armour clamp
for steel wire, steel tape, screened or braided cable. The armour clamp provides an electrical bond between the cable
armour and the gland. CR-1 can also be used to terminate unarmoured or lead sheathed cables. CR-1 type glands
maintain Flameproof Exd and Increased Safety Exe methods of explosion protection, IP66, IP68 to 25 metres and is
deluge resistant. An integral O ring entry thread seal is fitted to metric versions as standard.
Design Standard

EN50014:1998, EN50018:2000, EN50019:2000 &


EN 50281-1-1:1998
ATEX II 2 GD, E Exd IIC / E Exe II
GOST R-Exd IICU/Exe IIU
CSA Exd IIC/Exe II 4X, Class 1, Zone 1
IECEx Ex d IIC / Ex e II
NEPSI Exd IIC / Exe II

CERTIFication

CERTIFicate

BAS01ATEX2271X - Ex Notified Body No. 0518


POCC GB 05.B00482
CSA 1356011
IECEx SIR 05.0020X
NEPSI GYJ06189X

GLAND MARKING

CENELEC and ATEX


Example:
Peppers GU15 3BT UK CE0600 CR -1B SIZE/THREAD XX BAS 01ATEX2271X

II 2GD EExdIIC / EExe II (XX = Year Code)

EExd Equipment
CR-1B type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and
compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2

APPLICATION

Gas Group Internal Ignition Source


I IC, IIB, IIA
IIB, IIA
IIB, IIA

NO
YES
YES

EExe Equipment

Gas Group II, Zones 1 and 2

Enclosure Volume
Any
Any
2 litres or less

Which Zone Use Type CR-1B Gland


Zone 1 or 2
Zone 2
Zone 1

YES
YES
YES

Other Equipment
Ignitable Dust, Zones 21 and 22

INGRESS
PROTECTION

IP66 and IP68 @ 25 metres, Enclosure Type 4X


Meets the requirements of DTS01 1991

MATERIALS

Brass CZ121 (CR-*B)


316 Stainless Steel (CR-*S)
Inner & outer sheath material: Standard (CR-1) Neoprene, black. Option (CR-3) Silicone, white.
Reduced bore outer sheath seal (R) Silicone, red. (CR-**R)
Entry thread seal: Nitrile is supplied with neoprene seal version. Silicone is supplied with silicone seal version
For Lead Sheath Cables the gland is fitted with a metallic continuity washer:
Brass (CR-2B); 316 Stainless Steel (CR-2S)

VARIATIONS

Omission of outer seal: Brass (CR-DB); Stainless Steel (CR-DS)


Omission of inner seal [Exe Only]: Brass (CR-OB); Stainless Steel (CR-OS)
options

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

Seals

Extended operating temperature -60C to +180C, halogen free versions:


Brass (CR-3B); 316 Stainless Steel (CR-3S)

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

OPERATING
TEMPERATURES

Standard Seals -20C to +85C


Silicone Seals -60C to +180C

2006 Catalogue Page 1.1.0

Peppers Cable Glands Limited 2006

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC)
Gland and accessory kits:
K1 - includes gland, locknut, earthtag, integral IP O ring and PVC shroud
Note: Glands with non metric threads are supplied with flat IP washers.
Sample: CR-1B R K1/ZP/20S/M20
CR-1:
CR-* - Gland type
**1 - Seal material (Neoprene)

example part
number

B
- Body material (Brass)
R - Reduced bore outer seal
K1 - Supplied complete with accessories (PVC Shroud)
ZP - Zinc plating
20s - Gland size with regards to cable acceptance range
M20 - Entry thread
Gland
Size

Entry
Thread
Length

Entry Threads

Max
Max
Across Protrusion
Corners Length

Gland Seal Range


Cable Inner
Sheath [C]
Min Max

Metric

16

NPT/BSP

[B]

[A]

Cable Outer Sheath [D]


Standard
Min

Reduced (R)

Armour
Acceptance
Range

Max

Min

Max

6.7

10.3

0.15 - 1.25

Shroud
Size

M20

12

or 34

16

28.0

78.0

3.4

8.4

9.0

13.5

or

34

16

28.0

78.0

7.2

11.7

11.5

16.0

9.4

12.5

0.15 - 1.25

L24

or 34

16

33.0

78.0

9.4

14.0

15.5

21.1

12.0

17.6

0.15 - 1.25

EL30

L24

20s

M20

12

20

M20

12

25

M25

34

or 1

16

41.4

90.0

13.5

20.0

20.3

27.4

16.8

23.9

0.15 - 1.60

EL38

32

M32

1 or 114

16

50.6

105.0

19.5

26.3

26.7

34.0

23.2

30.5

0.15 - 2.00

EL46

16

60.5

113.0

23.0

32.2

33.0

40.6

28.6

36.2

0.20 - 2.00

EL55

16

71.5

125.0

28.1

38.2

39.4

46.7

34.8

42.4

0.30 - 2.50

EL65

114

112

40

M40

50s

M50

50

M50

16

71.5

125.0

33.1

44.1

45.7

53.2

41.1

48.5

0.30 - 2.50

EL65

63s

M63

2 or 212

19

88.0

125.0

39.2

50.1

52.1

59.5

47.5

54.8

0.30 - 2.50

EL80

19

88.0

125.0

46.7

56.0

58.4

65.8

53.8

61.2

0.30 - 2.50

EL80

19

99.0

131.0

52.1

62.0

64.8

72.2

60.2

68.0

0.30 - 2.50

EL90

or

112 or 2

63

M63

212

75s

M75

212 or 3

75

M75

19

99.0

131.0

58.0

68.0

71.1

78.0

66.5

73.4

0.30 - 2.50

EL90

80

M80 x 2

3 or 312

25

115.2

170.0

62.2

72.0

77.0

84.0

0.45 - 3.15

L104

312

80H

M80 x 2

3 or

25

115.2

170.0

62.2

72.0

79.6

90.0

0.45 - 3.15

L104

85

M85 x 2

3 or 312

25

115.2

170.0

69.0

78.0

79.6

90.0

75.0

85.4

0.45 - 3.15

L104

90

M90 x 2

312

or 4

25

125.7

170.0

74.0

84.0

88.0

96.0

0.45 - 3.15

L114

90H

M90 x 2

312 or 4

25

125.7

170.0

74.0

84.0

92.0

102.0

0.45 - 3.15

L114

M100 x 2

312

25

125.7

170.0

82.0

90.0

92.0

102.0

87.4

97.4

0.45 - 3.15

L114

100

or 4

All Dimensions are in mm


NOTES:

Gland Size does not necessarily equate to the entry thread size

Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required

Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be
achieved for tapered threads

Where CR-1 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth
circuit of the system

The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/
installation

Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

When used to terminate unarmoured cable, the gland is suitable only for fixed installations. The cable must be clamped near the
gland to prevent pulling and twisting.

Peppers Cable Glands Limited 2006

Page 1.1.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Cable Gland:- Type E1WF


Part of our ATEX Gland Range
2006 Catalogue Page 1.2.0
E1WF family of glands provide a seal on the inner sheath, a seal on the outer sheath and a specific armour clamp
for steel wire, steel tape, screened or braided cable. The armour clamp provides an electrical bond between the
cable armour and the gland. E2*F can be used to terminate lead sheathed cables. E1WF family of glands maintain
Flameproof Exd and Increased Safety Exe methods of explosion protection, IP66 and IP67.
Design Standard

EN50014:1998, EN50018:2000, EN50019:2000 and


EN 50281-1-1:1998
ATEX II 2 GD, E Exd IIC / E Exe II
GOST R-Exd IICU/Exe IIU
IECEx Ex d IIC / Ex e II
NEPSI Exd IIC / Exe II

CERTIFication

CERTIFicate

SIRA 01ATEX1271X - Ex Notified Body No. 0518


POCC GB 05.B00482
IECEx SIR 05.0020X
NEPSI GYJ06187X

GLAND MARKING

CENELEC and ATEX


Example:
Peppers GU15 3BT UK E1WF SIZE/THREAD XX SIRA
01ATEX1271X
II 2GD IP67 EExdIIC / EExe II
(XX = Year Code)

APPLICATION

Exd Equipment
E
E1WF type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and
compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2
Gas Group
IIC, IIB, IIA
IIB, IIA
IIB, IIA

Internal Ignition Source


NO
YES
YES

EExe Equipment
Gas Group II, Zones 1 and 2
INGRESS
PROTECTION

IP66 and IP67

MATERIALS

Brass CZ121 (E1WF)


316 Stainless Steel (E1WSF)

Enclosure Volume
Any
Any
2 litres or less

Which Zone
Zone 1 or 2
Zone 2
Zone 1

Use E1WF Gland


YES
YES
YES

Other Equipment
Ignitable Dust, Zones 21 and 22

Inner & outer sheath seal material: Standard (E1) Neoprene, black. Option (E3) Silicone, white.
Reduced bore outer sheath seal (R) Silicone, red. (E1WFR).
VARIATIONS

options

For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (E2WF); 316 Stainless Steel (E2WSF).
Integral Earth version for HV applications:
Brass (E1WIEF); 316 Stainless Steel (E1WIESF)
Omission of outer seal:
Brass (D1WF); 316 Stainless Steel (D1WSF)
THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

Seals

Extended operating temperature -60C to +180C, halogen free versions:


Brass (E3WF); 316 Stainless Steel (E3WSF)

CLAMPS

SWA steel wire armour (E1WF)


SWB woven steel wire armour (E1XF)
STA steel tape armour (E1ZF)

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

OPERATING
TEMPERATURES

Standard Seals -20C to +85C


Silicone Seals -60C to +180C

2006 Catalogue Page 1.2.0

Peppers Cable Glands Limited 2006

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC); PCP (ACSPCP); Low Smoke Zero Halogen (ACSSIO)

accessories

Gland and accessory kits:


CK1 - includes gland, locknut, earthtag, fibre IP washer and PVC shroud
K1- includes gland, locknut, earthtag, nylon IP washer and PCP shroud
E3WFK1 - includes brass gland, brass locknut, brass earthtag, IP washer and zero halogen shroud
example part
number

Sample: E1WF R CK1/ZP/20S/M20


E1WF:
E*WF - Gland type, armour type (SWA) and body material (Brass)
*1** - Seal material (Neoprene)
R
CK1
ZP
20s
M20

Gland
Size

Reduced bore outer seal


Supplied complete with accessories (PVC Shroud)
Zinc plating
Gland size with regards to cable acceptance range
Entry thread
Entry
Thread
Length

Entry Threads

[B]
Metric

16

Max
Max
Across Protrusion
Corners
Length

Gland Seal Range


Cable Inner
Sheath [C]
Min Max

[A]

Armour Acceptance
Range

Cable Outer Sheath [D]


Standard
Min

Max

Shroud
Size

Reduced (R)
Min

Max

XZ

10.0

0.90

0.15-0.35

L24

NPT/BSP

M20

12

or 34

16

26.5

58.0

4.0

8.4

8.4

13.5

or

34

16

26.5

58.0

8.0

11.7

11.5

16.0

9.4

12.5

0.90-1.25

0.15-0.35

L24

or 34

16

33.0

58.0

6.7

14.0

15.5

21.1

12.0

17.6

0.90-1.25

0.15-0.50

L30

20s

M20

12

20

M20

12

4.9

25

M25

34

or 1

16

41.4

58.0

13.0

20.0

20.3

27.4

16.8

23.9

1.25-1.60

0.15-0.50

L38

32

M32

1 or 114

16

50.6

65.0

19.0

26.3

26.7

34.0

23.2

30.5

1.60-2.00

0.15-0.55

L46

40

M40

50s

M50

50

63s

114 or

112

16

60.5

72.0

25.0

32.2

33.0

40.6

28.6

36.2

1.60-2.00

0.20-0.60

L55

112 or 2

16

71.5

73.0

31.5

38.2

39.4

46.7

34.8

42.4

2.00-2.50

0.20-0.60

L65

M50

16

71.5

73.0

36.5

44.1

45.7

53.2

41.1

48.5

2.00-2.50

0.30-0.80

L65

M63

2 or 212

19

88.0

76.0

42.5

50.1

52.1

59.5

47.5

54.8

2.50

0.30-0.80

L80

19

88.0

76.0

49.5

56.0

58.4

65.8

53.8

61.2

2.50

0.30-0.80

L80

19

99.0

82.0

54.5

62.0

64.8

72.2

60.2

68.0

2.50

0.30-1.00

L90

63

M63

212

75s

M75

212 or 3

75

M75

19

99.0

82.0

60.5

68.0

71.1

78.0

66.5

73.4

2.50

0.30-1.00

L90

80

M80 x 2

3 or 312

25

115.2

110.0

62.2

72.0

77.0

84.0

3.15

0.45-1.00

L104

80H

M80 x 2

3 or 312

25

115.2

110.0

62.2

72.0

79.6

90.0

3.15

0.45-1.00

L104

85

M85 x 2

3 or 312

25

115.2

110.0

69.0

78.0

79.6

90.0

75.0

85.4

3.15

0.45-1.00

L104

90

M90 x 2

312

or 4

25

125.7

110.0

74.0

84.0

88.0

96.0

3.15

0.45-1.00

L114

90H

M90 x 2

312 or 4

25

125.7

110.0

74.0

84.0

92.0

102.0

3.15

0.45-1.00

L114

M100 x 2

312

25

125.7

110.0

82.0

90.0

92.0

102.0

87.4

97.4

3.15

0.45-1.00

L114

100

or 4

All Dimensions are in Millimetres


NOTES:

Gland Size does not necessarily equate to the entry thread size

"W" refers to the wire diameter in a steel wire armoured cable

"XZ" refers to the wire diameter in a woven steel wire armoured cable or the tape thickness in a steel tape armoured cable

E3*F gland size 20, the silicone inner seal only seals to a minimum of 11.0mm and NOT 6.7mm

Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be
achieved for tapered threads

Where E1WF type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit
of the system

The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation

Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

Peppers Cable Glands Limited 2006

Page 1.2.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Cable Gland:- Type CWLE


Part of our ATEX Gland Range
2006 Catalogue Page 1.3.0
CWLE type glands provide a seal on the outer sheath and an armour specific armour clamp for armoured cable. The
armour clamp provides an electrical bond between the cable armour and the gland. CWLE type glands maintain
Increased Safety Exe methods of explosion protection and IP66.

Design Standard

EN 50014:1998, EN 50019:2000 and EN 50281-11:1998


B

ATEX II 2 GD, E Exe II


GOST R-Exd IICU/Exe IIU
IECEx Ex e II
NEPSI Exd IIC / Exe II

CERTIFication

CERTIFicate

SIRA 01ATEX3273 - Ex Notified Body No. 0518


POCC GB 05.B00482
IECEx SIR 05.0020X
NEPSI GYJ06187X

GLAND MARKING

CENELEC and ATEX


Example:
Peppers GU15 3BT UK CWLE SIZE/THREAD XX
SIRA 01ATEX3273X
II 2GD IP66 EExe II
( XX = Year Code)

APPLICATION

EExe Equipment

Gas Group II, Zones 1 and 2

Other Equipment
Ignitable Dust, Zones 21 and 22

INGRESS
PROTECTION

IP66

MATERIALS

Brass CZ121 (CWLE)


316 Stainless Steel (CWLSE)
Outer sheath material: Standarrd (C) Neoprene, black. Option (C3) Silicone, white.
Reduced outer bore sheath seal (R) Silicone, red. (CWLR)

VARIATIONS

Integral Earth version for HV applications:


Brass (CWLIEE); 316 Stainless Steel (CWLSIEE)

options

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

Seals

Extended operating temperature -60C to +180C, halogen free versions:


Brass (C3WLE); 316 Stainless Steel (C3WLSE)

CLAMPS

SWA steel wire armour (CWLE)


SWB woven steel wire armour or STA steel tape armour (CXZLE)

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

OPERATING
TEMPERATURES

Standard Seals -20C to +85C


Silicone Seals -60C to +180C

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC); PCP (ACSPCP); Low Smoke Zero Halogen (ACSSIO)
Gland and accessory kits:
K1- includes gland, locknut, earthtag, nylon IP washer and PVC shroud
C3WLEK1 - includes brass gland, brass locknut, brass earthtag, IP washer and zero halogen shroud

2006 Catalogue Page 1.3.0

Peppers Cable Glands Limited 2006

example part
number

Sample: CWLE R K1/ZP/20S/M20


CWLE:
CWLE - Gland type, seal material, armour type (SWA) and body material (Brass)
C3WLE - Seal material (Silicone)
R - Reduced bore outer seal
K1 - Supplied complete with accessories (PVC Shroud)
ZP - Zinc plating
20s - Gland size with regards to cable acceptance range
M20 - Entry thread

Gland
Size

Entry Threads

Entry
Max
Max
Thread Across Protrusion
Length Corners
Length
[B]

Metric

16

Gland Seal Range


Cable Inner
Sheath [C]
Min Max

[A]

Armour Acceptance
Range

Cable Outer Sheath [D]


Standard
Min

Max

Shroud
Size

Reduced (R)
Min

Max

XZ

10.3

0.90-1.25

0.15-0.35

L24

NPT/BSP

M20

12

or 34

16

26.5

54.0

8.4

9.0

13.5

or

34

16

26.5

54.0

11.7

11.5

16.0

9.4

12.5

0.90-1.25

0.15-0.35

L24

or 34

16

33.0

54.0

14.0

15.5

21.0

12.0

17.6

0.90-1.25

0.15-0.50

L30

20s

M20

12

20

M20

12

6.7

25

M25

34

or 1

16

41.4

54.0

20.0

20.3

27.4

16.8

23.9

1.25-1.60

0.15-0.50

L38

32

M32

1 or 114

16

50.6

60.0

26.3

26.7

34.0

23.2

30.5

1.60-2.00

0.15-0.55

L46

40

M40

50s

M50

50

63s

114

or

112

16

60.5

67.0

32.2

33.0

40.6

28.6

36.2

1.60-2.00

0.20-0.60

L55

112 or 2

16

71.5

67.0

38.2

39.4

46.7

34.8

42.4

2.00-2.50

0.20-0.60

L65

M50

16

71.5

67.0

44.1

45.7

53.2

41.1

48.5

2.00-2.50

0.30-0.80

L65

M63

2 or 212

19

88.0

69.0

50.1

52.1

59.5

47.5

54.8

2.50

0.30-0.80

L80

63

M63

212

19

88.0

69.0

56.0

58.4

65.8

53.8

61.2

2.50

0.30-0.80

L80

75s

M75

212 or 3

19

99.0

77.0

62.0

64.8

72.2

60.2

68.0

2.50

0.30-1.00

L90

75

M75

19

99.0

77.0

68.0

71.1

78.0

66.5

73.4

2.50

0.30-1.00

L90

80

M80 x 2

3 or 312

25

115.2

104.0

72.0

77.0

84.0

3.15

0.45-1.00

L104

80H

M80 x 2

3 or 312

25

115.2

104.0

72.0

79.6

90.0

3.15

0.45-1.00

L104

85

M85 x 2

3 or 312

25

115.2

104.0

78.0

79.6

90.0

75.0

85.4

3.15

0.45-1.00

L104

90

M90 x 2

312 or 4

25

125.7

104.0

84.0

88.0

96.0

3.15

0.45-1.00

L114

90H

M90 x 2

312

or 4

25

125.7

104.0

84.0

92.0

102.0

3.15

0.45-1.00

L114

100

M100 x 2

312 or 4

25

125.7

104.0

90.0

92.0

102.0

87.4

97.4

3.15

0.45-1.00

L114

All Dimensions are in Millimetres


NOTES:

Gland Size does not necessarily equate to the entry thread size

"W" refers to the wire diameter in a steel wire armoured cable

"XZ" refers to the wire diameter in a woven steel wire armoured cable or the tape thickness in a steel tape armoured cable

Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

Where CWLE type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit
of the system

The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation

Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 1.3.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Cable Gland:- Type A2LF


Part of our ATEX Gland Range
2006 Catalogue Page 2.1.0
A2LF type glands provide a single pull resistant seal on the outer sheath of any cable. A2LF type glands maintain
Flameproof Exd and Increased Safety Exe methods of explosion protection, IP66 & IP68 to 25 metres. An integral O ring
entry thread seal is fitted to metric versions as standard.

Design Standard

EN50014:1998, EN50018:2000, EN50019:2000 and


EN 50281-1-1:1998
ATEX II 2 GD, E Exd IIC / E Exe II
GOST R-Exd IICU/Exe IIU
CSA Exd IIC/Exe II 4X, Class 1, Zone 1
IECEx Exd IIC / Exe II
NEPSI Exd IIC / Exe II

CERTIFication

CERTIFicate

SIRA 01ATEX1272X - Ex Notified Body No. 0518


POCC GB 05.B00482
CSA 1356011
IECEx SIR 05.0020X
NEPSI GYJ06186X

GLAND MARKING

CENELEC and ATEX


Example:
Peppers GU15 3BT UK A2LF SIZE/THREAD XX SIRA
01ATEX1272X
II 2GD IP68 EExdIIC / EExe II (XX =
Year Code)

APPLICATION

Exd Equipment
E
A2LF type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and
compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2

INGRESS
PROTECTION

Gas Group Internal Ignition Source


IIC, IIB, IIA
NO
IIB, IIA
YES
IIB, IIA
YES

Enclosure Volume
2 litres or less
Any
2 litres or less

Which Zone
Zone 1 or 2
Zone 2
Zone 1

EExe Equipment

Gas Group II, Zones 1 and 2

Other Equipment
Ignitable Dust, Zones 21 and 22

Use A2LF Gland


YES
YES
YES

IP66 and IP68 @ 25 metres, Enclosure Type 4X


Brass CZ121 (A2LF)
316 Stainless Steel (A2LSF)
Aluminium Alloy (A2LAF)

MATERIALS

Outer sheath seal material:


Standard (A2L) Neoprene, black. Option (A3L) Silicone, white.
Integral entry thread seal: Nitrile is supplied with neoprene outer seal version. Silicone is supplied with silicone
outer seal version
For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (A4LF); 316 Stainless Steel (A4LSF)

VARIATIONS

options

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

Seals

Extended operating temperature -60C to +180C, halogen free versions:


Brass (A3LF); 316 Stainless Steel (A3LSF)

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

OPERATING
TEMPERATURES

Standard Seals -20C to +85C


Silicone Seals -60C to +180C

2006 Catalogue Page 2.1.0

Peppers Cable Glands Limited 2006

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN); Aluminium (ACALN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET); Aluminium (ACAET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC); PCP (ACSPCP); Low Smoke Zero Halogen (ACSSIO)
Gland and accessory kits:
CK1 - includes gland, locknut, integral IP O ring and PVC shroud
K1 - includes gland, locknut, integral IP O ring and PCP shroud
Note: Glands with non metric threads are supplied with flat IP washers.

example part
number

Sample: A2LF CK1/ZP/20S/M20


A2LF:
A*LF - Gland type and body material (Brass)
*2** - Seal material (Neoprene)
CK1 ZP 20s M20 -

Gland Size

Supplied complete with accessories (PVC Shroud)


Zinc plating
Gland size with regards to cable acceptance range
Entry thread

Entry Threads

Metric

Entry Thread
Length

Max Across
Corners

[B]

[A]

Gland Seal Range

Max
Protrusion
Length

Shroud Size

Cable Outer/Lead Sheath


Min

Max

NPT/BSP

16

M20

12

or 34

16

28.0

33.0

4.0

8.4

L24

20s

M20

12

or 34

16

28.0

33.0

7.2

11.7

L24

34

20

M20

12

16

33.0

33.0

9.6

14.0

L30

25

M25

34 or 1

16

41.4

33.0

13.5

20.0

L38

M32

114

16

50.6

33.0

19.5

26.3

L46

16

60.5

37.0

23.0

32.2

L55

16

71.5

37.0

28.2

38.2

L65

32

or

1 or

40

M40

50s

M50

50

M50

16

71.5

37.0

33.2

44.1

L65

63s

M63

2 or 212

19

88.0

37.0

39.3

50.1

L80

63

M63

212

19

88.0

37.0

46.7

56.0

L80

75s

M75

212 or 3

19

99.0

37.0

52.3

62.0

L90

75

M75

19

99.0

37.0

58.1

68.0

L90

80

M80 x 2

3 or 312

25

115.2

50.0

62.3

72.0

L104

85

M85 x 2

3 or 312

25

115.2

50.0

69.1

78.0

L104

90

M90 x 2

312 or 4

25

125.7

50.0

74.1

84.0

L114

M100 x 2

312

25

125.7

50.0

82.0

90.0

L114

100

114 or

112

112 or 2

or 4

All Dimensions are in Millimetres


NOTES:

Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting

Gland Size does not necessarily equate to the entry thread size

Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required

Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be
achieved for tapered threads

Where A2LF type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit
of the system

The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/
installation

Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 2.1.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Cable Gland:- Type A2LDSF


Part of our ATEX Gland Range
2006 Catalogue Page 2.2.0
A2LDSF type glands provide two pull resistant seals on the outer sheath of any cable. A2LDSF type glands maintain
Flameproof Exd and Increased Safety Exe methods of explosion protection and IP66, IP68 to 25 metres. An integral O
ring entry thread seal is fitted to metric versions as standard.

Design Standard

EN50014:1998, EN50018:2000, EN50019:2000 and


EN 50281-1-1:1998
ATEX II 2 GD, E Exd IIC / E Exe II
GOST R-Exd IICU/Exe IIU
CSA Exd IIC/Exe II 4X, Class 1, Zone 1
IECEx Ex d IIC / Ex e II
NEPSI Exd IIC / Exe II

CERTIFication

SIRA 01ATEX1272X - Ex Notified Body No. 0518


POCC GB 05.B00482
CSA 1356011
IECEx SIR 05.0020X
NEPSI GYJ06186X

CERTIFicate

GLAND MARKING

CENELEC and ATEX


Example:
Peppers GU15 3BT UK A2LDSF SIZE/THREAD XX
SIRA 01ATEX1272X
II 2GD IP68 EExdIIC / EExe II
(XX = Year Code)

APPLICATION

Exd Equipment
E
A2LDSF type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and
compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2
Gas Group Internal Ignition Source
IIC, IIB, IIA
NO
IIB, IIA
YES
IIB, IIA
YES

Enclosure Volume
Any
Any
2 litres or less

EExe Equipment
Gas Group II, Zones 1 and 2

Other Equipment
Ignitable Dust, Zones 21 and 22

INGRESS
PROTECTION

IP66 and IP68 @ 25 metres, Enclosure Type 4X

MATERIALS

Brass CZ121 (A2LDSF)


316 Stainless Steel (A2LDSSF)
Aluminium Alloy (A2LDSAF)

Which Zone
Zone 1 or 2
Zone 2
Zone 1

Use A2LDSF Gland


YES
YES
YES

Outer sheath seal material:


Standard (A2LDSF) Neoprene, black. Option (A3LDSF) Silicone, white.
Integral entry thread seal: Nitrile is supplied with neoprene outer seal version. Silicone is supplied with silicone
outer seal version.
VARIATIONS

options

For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (A4LDSF); 316 Stainless Steel (A4LDSSF)
THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

Seals

Extended operating temperature -60C to +180C, halogen free versions:


Brass (A3LDSF); 316 Stainless Steel (A3LDSSF); Aluminium (A3LDSAF)

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

OPERATING
TEMPERATURES

Standard Seals -20C to +85C


Silicone Seals -60C to +180C

2006 Catalogue Page 2.2.0

Peppers Cable Glands Limited 2006

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN); Aluminium (ACALN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET); Aluminium (ACAET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC); PCP (ACSPCP); Low Smoke Zero Halogen (ACSSIO)

example part
number

Sample: A2LDSF /ZP/20S/M20


A2LDSF:
A*LDSF - Gland type and body material (Brass)
*2**** - Seal material (Neoprene)
ZP
20s
M20

Gland Size

- Zinc plating
- Gland size with regards to cable acceptance range
- Entry thread

Entry Threads

Entry Thread
Length

Max Across
Corners

Max Protrusion
Length

Gland Seal Range

Shroud Size

Cable Outer Sheath [D]

Metric

[B]

[A]

Min

Max

NPT/BSP

16

M20

12

or 34

16

28.0

66.0

4.0

8.4

L24

20s

M20

12

or 34

16

28.0

66.0

7.2

11.7

L24

12

34

20

M20

25

M25

34

32

M32

1 or 114

16

45.1

66.0

19.5

26.3

L41

40

M40

114 or 112

16

55.9

74.0

23.0

32.2

L51

50s

M50

112 or 2

16

71.5

74.0

28.2

38.2

L65

50

M50

16

71.5

74.0

33.2

44.1

L65

19

88.0

74.0

39.3

50.1

L80

19

88.0

74.0

46.7

56.0

L80

19

99.0

74.0

52.3

62.0

L90

63s

M63

63

M63

2 or

or 1

212

212
212

16

29.7

66.0

9.6

14.0

L27

16

39.6

66.0

13.5

20.0

L36

75s

75

M75

19

99.0

74.0

58.1

68.0

L90

80

M80 x 2

3 or 312

25

115.2

100.0

62.3

72.0

L104

85

M85 x 2

3 or 312

25

115.2

100.0

69.1

78.0

L104

90

M90 x 2

312 or 4

25

125.7

100.0

74.1

84.0

L114

M100 x 2

312

25

125.7

100.0

82.0

90.0

L114

100

M75

or

or 3

or 4

All Dimensions are in Millimetres


NOTES:

Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting

Gland Size does not necessarily equate to the entry thread size

Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required

Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be
achieved for tapered threads

Where A2LF type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit
of the system

The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/
installation

Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 2.2.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Cable Gland:- Type A2LCMF and A2LCFF


Part of our ATEX Gland Range
2006 Catalogue Page 2.3.0
A2LCMF and A2LCFF type glands provide a seal on the outer sheath of unarmoured cable and a conduit connection
thread. A2LCMF type glands provide a male thread for connection and A2LCFF type glands provide a female thread for
connection. A2LCMF and A2LCFF type glands maintain Flameproof Exd and Increased Safety Exe methods of explosion
protection and IP66, IP68 to 25 metres. An O ring IP entry thread seal is fitted as standard.
Design Standard

EN50014:1998, EN50018:2000, EN50019:2000 and


EN 50281-1-1:1998
ATEX II 2 GD, E Exd IIC / E Exe II
GOST R-Exd IICU/Exe IIU
CSA Exd IIC/Exe II 4X, Class 1, Zone 1
IECEx Ex d IIC / Ex e II
NEPSI Exd IIC / Exe II

CERTIFication

CERTIFicate

SIRA 01ATEX1272X - Ex Notified Body No. 0518


POCC GB 05.B00482
CSA 1356011
IECEx SIR 05.0020X
NEPSI GYJ06186X

GLAND MARKING

CENELEC and ATEX


Example: Peppers GU15 3BT UK A2LCFF SIZE/
THREAD XX SIRA 01ATEX1272X
II 2GD IP68
EExdIIC / EExe II (XX = Year Code)

APPLICATION

Exd Equipment
E
A2L**F type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and
compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2
Gas Group
IIC, IIB, IIA
IIB, IIA
IIB, IIA

Internal Ignition Source


NO
YES
YES

Enclosure Volume
Any
Any
2 litres or less

EExe Equipment


Gas Group II, Zones 1 and 2

INGRESS
PROTECTION

IP66 and IP68 @ 25 metres, Enclosure Type 4X

MATERIALS

Brass CZ121 (A2L**F)


316 Stainless Steel (A2L**SF)
Aluminium Alloy (A2L**AF)

Which Zone
Zone 1 or 2
Zone 2
Zone 1

Use A2L**F Gland


YES
YES
YES

Other Equipment
Ignitable Dust, Zones 21 and 22

Outer sheath seal material:


Standard (A2L**F) Neoprene, black. Option (A3L**F) Silicone, white.
Integral entry thread seal: Nitrile is supplied with neoprene outer seal version. Silicone is supplied with silicone
outer seal version.
options

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

Seals

Extended operating temperature -60C to +180C, halogen free versions:


Brass (A3L**F); 316 Stainless Steel (A3L**SF)

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

OPERATING
TEMPERATURES

Standard Seals -20C to +85C


Silicone Seals - 60C to +180C

2006 Catalogue Page 2.3.0

Peppers Cable Glands Limited 2006

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN); Aluminium (ACALN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET); Aluminium (ACAET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)

example part
number

Sample: A2LCFF M20/ZP/20S/M20


A2LCFF:
A*LCFF - Gland type (Female conection thread) and body material (Brass)
*2**** - Seal material (Neoprene)
M20 ZP 20s M20 -

Gland Size

Female connection thread


Zinc plating
Gland size with regards to cable acceptance range
Entry thread

Entry Threads

Metric

Entry Thread
Length

Max Across
Corners

[B]

[A]

Gland Seal Range

Conduit Connector

Cable Outer Sheath [D]


Min

Max

NPT/BSP

NPT

ISO

16

M20

12

or 34

16

28.0

4.0

8.4

12

or 34

M20

20s

M20

12

or 34

16

28.0

7.2

11.7

12

or 34

M20

12

34

12

34

20

M20

16

33.0

9.6

14.0

25

M25

34

or 1

16

41.4

13.5

20.0

34

or 1

M25

32

M32

1 or 114

16

50.6

19.5

26.3

1 or 114

M32

40

M40

114 or 112

16

60.5

23.0

32.2

114 or 112

M40

50s

M50

50

M50

or

112

or 2

2
2 or

212

16

71.5

28.2

38.2

16

71.5

33.2

44.1

or

112

or 2

2
212

M20

M50
M50

63s

M63

19

88.0

39.3

50.1

63

M63

212

19

88.0

46.7

56.0

212

M63

75s

M75

212 or 3

19

99.0

52.3

62.0

212 or 3

M75

75

M75

19

99.0

58.1

68.0

M75

2 or

M63

All Dimensions are in Millimetres


NOTES:

Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting

Gland Size does not necessarily equate to the entry thread size

Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required

Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be
achieved for tapered threads

Where A2LF type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit
of the system

The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/
installation

Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

Other conduit connection threads eg PG, BSP are available upon request

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 2.3.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Cable Gland:- Type RG22E


Part of our ATEX Gland Range
2006 Catalogue Page 2.4.0
RG22E type glands provide a seal on the outer sheath of unarmoured cable. RG22E type glands maintain Increased
Safety Exe method of explosion protection and IP66, IP68.

Design Standard

EN50014:1997 and EN50019:2000


ATEX II 2 GD, E Exe II

CERTIFication
CERTIFicate

SIRA 00ATEX 1072 - Ex Notified Body No. 0518

GLAND MARKING

Example:
SIRA 00ATEX1072X EB (Cable Range)
EExeII

II2GD

For industrial versions the hazardous area


information is omitted
APPLICATION

Exe Equipment
Gas Group II, Zones 1 and 2

INGRESS
PROTECTION

IP66 without a sealing washer


IP68 with a sealing washer

MATERIALS

Standard (RG22E) Black Polyamide 6


Option (RG22UE) Blue Polyamide 6
Industrial, Non Ex Versions (RG22) Grey Polyamide 6
Note: Polyamide 6 is self extinguishing, flame retardant and halogen free
Outer sheath seal material: Santoprene, black

THREADS

ISO Metric; PG

OPERATING
TEMPERATURES

Sizes M25 and below: -20C to +60C


Sizes above M25: -10C to +60C

accessories

Locknut - Nylon (ACNLN); Brass (ACBLN)


IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)

example part
number

Sample: RG22E/M20
RG22E:
RG22E - Gland type, certification (Exe) and body colour, black (RG22UE, Blue)

M20 - Gland size and entry thread

2006 Catalogue Page 2.4.0

Peppers Cable Glands Limited 2006

Gland Size

Metric

Entry
Thread
Length

Gland Seal Range


Cable Outer Sheath

Max
Across
Corners

PG

Min

Max

6.0

16.5

3.5

M16

20.9

5.0

8.0

11

24.2

6.0

10.0

M20

13.5

10

26.4

8.0

13.5

16

10

28.6

10.0

15.0

M25

21

11

35.2

13.0

19.0

M32

29

12

45.1

18.0

25.0

M40

36

14

57.2

24.0

32.0

M50

42

16

64.9

29.0

38.0

M63

48

16

71.5

36.0

44.0

All Dimensions are in Millimetres

NOTES:

Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting

Gland sizes M25 and above shall not be used for applications where there is a "high" risk of mechanical damage

Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 2.4.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Cable Gland:- Type E8XF


Part of our ATEX Gland Range
2006 Catalogue Page 3.1.0
E8XF type glands provide pull resistant seals on the inner and outer sheath and a braid armour clamp. The armour clamp
provides an electrical bond between the cable armour and the gland. E8XF type glands maintain Flameproof Exd and
Increased Safety Exe methods of explosion protection and IP66.

Design Standard

EN 50014:1998, EN 50018:2000, EN 50019:2000


and EN 50281-1-1:1998
ATEX II 2 GD, E Exd IIC / E Exe II
GOST R-Exd IICU/Exe IIU
IECEx Ex d IIC / Ex e II
NEPSI Exd IIC / Exe II

CERTIFication

CERTIFicate

SIRA 01ATEX1270X - Ex Notified Body No. 0518


POCC GB 05.B00482
IECEx SIR 05.0020X
NEPSI GYJ06185X

GLAND MARKING

CENELEC and ATEX


Example: Peppers GU15 3BT UK E8XF SIZE/
THREAD XX SIRA 01ATEX1270X
II 2GD IP66
EExdIIC / EExe II (XX = Year Code)

APPLICATION

Exd Equipment
E
E8XF type glands will only maintain Flameproof Exd integrity when used with cable that has a suitable profile and is
compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2
Gas Group
IIC, IIB, IIA
IIB, IIA
IIB, IIA

Internal Ignition Source


NO
YES
YES

EExe Equipment
Gas Group II, Zones 1 and 2
INGRESS
PROTECTION

Enclosure Volume
2 litres or less
Any
2 litres or less

Which Zone
Zone 1 or 2
Zone 2
Zone 1

Use E8XF Gland


YES
YES
YES

Other Equipment
Ignitable Dust, Zones 21 and 22

IP66

MATERIALS

options

Brass CZ121 (E8XF)


316 Stainless Steel (E8XSF)
Inner and Outer sheath seal material: Standard Silicone, red or white
THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

OPERATING
TEMPERATURES

-60C to +180C

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)

2006 Catalogue Page 3.1.0

Peppers Cable Glands Limited 2006

example part
number

Gland
Size

Sample: E8XF /ZP/20S/M20


E8XF:
E8XF - Gland type and body material (Brass)
ZP - Zinc plating
20s - Gland size with regards to cable acceptance range
M20 - Entry thread

Entry Threads

Metric

Entry
Thread
Length
[B]

Max Across
Corners

Max
Protrusion
Length

[A]

Gland Seal Range


Cable Inner Sheath [C]
Width
Thickness
Min Max

Min Max

Cable Outer Sheath [D]


Width
Min

Max

Thickness
Min

Armour
Acceptance
Range

Max
X

20s

M20

16

26.5

58.0

6.3

11.7

4.0

7.0

7.9

11.7

4.5

7.0

0.1-0.30

20R

M20

16

33.0

58.0

8.1

13.5

5.8

6.2

7.5

16.1

3.0

8.3

0.1-0.45

20

M20

16

33.0

58.0

10.3

13.5

5.6

9.0

11.0

13.5

4.5

9.0

0.1-0.30

All Dimensions are in Millimetres

NOTES:

Gland Size does not necessarily equate to the entry thread size

"X" refers to the wire diameter in a braided cable

Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be
achieved for tapered threads

Where E8XF type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit
of the system

The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation

Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 3.1.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Cable Gland:- Type A8F


Part of our ATEX Gland Range
2006 Catalogue Page 3.2.0
A8F type glands provide a single pull resistant seal on the outer sheath of unarmoured flat cable. A8F type glands
maintain Flameproof Exd and Increased Safety Exe methods of explosion protection and IP68 to 25 metres.

Design Standard

EN50014:1998, EN50018:2000, EN50019:2000 and


EN50281-1-1:1998
B

ATEX II 2 GD, E Exd IIC / E Exe II


GOST R-Exd IICU/Exe IIU

CERTIFication

IECEx Ex d IIC / Ex e II
NEPSI Exd IIC / Exe II
A

CERTIFicate

SIRA 01ATEX1270X - Ex Notified Body No. 0518


POCC GB 05.B00482
IECEx SIR 05.0020X
NEPSI GYJ06185X

GLAND MARKING

CENELEC and ATEX


Example:
Peppers GU15 3BT UK A8F SIZE/THREAD XX SIRA
01ATEX1270X
II 2GD IP68 EExdIIC / EExe II (XX =
Year Code)

APPLICATION

Exd Equipment
E
A8F type glands will only maintain Flameproof Exd integrity when used with cable that has a suitable profile and is
compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2
Gas Group
IIC, IIB, IIA
IIB, IIA
IIB, IIA

Internal Ignition Source


NO
YES
YES

Enclosure Volume
Any
Any
2 litres or less

Which Zone
Zone 1 or 2
Zone 2
Zone 1

EExe Equipment

Other Equipment

Gas Group II, Zones 1 and 2

Ignitable Dust, Zones 21 and 22

INGRESS
PROTECTION

IP68 @ 25 metres

MATERIALS

Brass CZ121 (A8F)


316 Stainless Steel (A8SF)
Outer sheath seal material: Silicone, red or white

options

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

OPERATING
TEMPERATURES

-60C to +180C

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN)

Use A8F Gland


YES
YES
YES

Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET)


IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)

2006 Catalogue Page 3.2.0

Peppers Cable Glands Limited 2006

example part
number

Sample: A8F /ZP/20S/M20


A8F:
A8F - Gland type and body material (Brass)
ZP - Zinc plating
20s - Gland size with regards to cable acceptance range
M20 - Entry thread

Gland
Size

Entry
Thread
Length

Max
Across
Corners

Metric

[B]

[A]

20s

M20

16

20R

M20

16

M20

16

20

Entry Threads

Gland Seal Range


Cable Outer Sheath [D]
Width

Thickness

Min

Max

Min

Max

26.5

6.3

11.7

4.0

7.0

33.0

8.1

13.5

5.8

6.2

33.0

10.3

13.5

5.6

9.0

All Dimensions are in Millimetres

NOTES:

Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting

Gland Size does not necessarily equate to the entry thread size

Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required

Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be
achieved for tapered threads

Where A8F type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit
of the system

The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation

Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 3.2.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Type CR-C Barrier Gland For Armoured Cable featuring CROCLOCK


Part of our ATEX Gland Range
2006 Catalogue Page 4.1.0

Croclock CR-C type glands provide a Flameproof EExd compound filled barrier, a seal on the outer sheath, a universal
armour clamp for armoured, screened or braided cable and an entry thread seal. The armour clamp provides an
electrical bond between the cable armour, screen or braid and the gland. Croclock CR-C type glands maintain EExd
Flameproof method of explosion protection; IP66, 68 to 100 metres and is deluge resistant.
Design Standard

EN50014:1998, EN50018:2000 & EN 50281-1-1:1998


IEC 60079-0 (2000-06), IEC 60079-1 (2001-02)
ATEX I M2 II 2 GD, E Exd I & IIC
GOST R-Exd I & IICU
CSA Exd I & IIC 4X, Class 1, Zone 1
CSA A Exd IIC / A Exe II 4X, Class 1, Zone 1
IECEx Exd IIC / Exd I
NEPSI Exd IIC / Exe II

CERTIFication

CERTIFicate

SIRA 03ATEX1479X - Ex Notified Body No. 0518


POCC GB 05.B00974
CSA 1356011
IECEx SIR 05.0020X
NEPSI GYJ06188X

GLAND MARKING

CENELEC & ATEX

Example:
SIRA 03ATEX1479X

I M2 II 2GD EExd I & IIC IP68 PEPPERS UK / XX / CR-CB - 20S (XX = Year Code)

Exd Equipment
E
CR-C type glands will maintain Flameproof Exd integrity when used with any armoured or unarmoured cable types.
Ref: IEC60079-14:2002 Section 10.4.2

APPLICATION

Gas Group

Internal Ignition Source

Enclosure Volume

Which Zone

Use CR-C Gland

I, IIC, IIB, IIA

YES

Any

Zone 1 or 2

YES

Other Equipment
Mining Equipment Group I, M2
Ignitable Dust, Zones 21 and 22
INGRESS
PROTECTION

IP66 & IP68 @ 100 metres


Meets the requirements of DTS01 1991

CURING TIME

@ 21C
Conductor termination can be effected after 1 hour
The equipment can be energised after 4 hours
The compound chamber can be inspected after 4 hours

VARIATIONS

For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (CR-C2B); Stainless Steel (CR-C2S)

MATERIALS

Brass CZ121 (CR-CB)


316 Stainless Steel (CR-CS)
Inner LSOH compound
Standard outer sheath seal is LSOH silicone, white (CR-C*)
Reduced bore outer sheath seal is LSOH silicone, red (CR-C*R)
Entry thread seal: Red LSOH silicone

options

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

OPERATING
TEMPERATURES

- 60C to +85C

2006 Catalogue Page 4.1.0

Peppers Cable Glands Limited 2006

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC)
Gland and accessory kits:
K1- includes gland, locknut, earthtag, integral IP O ring & PVC shroud
Note: Glands with non metric threads are supplied with flat IP washers

example part
number

Gland
Size

Sample: CR-CB R K1/NP/20S/M20


CR-C:
CR-C - Gland type
**-*B - Material (Brass)
R
- Reduced bore outer seal
K1 - Supplied complete with accessories (PVC Shroud)
NP - Nickel plating
20s - Gland size with regards to cable acceptance range
M20 - Entry thread

Entry Threads

Metric

Entry
Thread
Length

Max
Across
Corners

[B]

[A]

Max
Protrusion
Length

Gland Seal Range


Cable Inner
Sheath / Cores [C]
Max
No. of
Cores

NPT/BSP

Max
Over
Cores

Max
Inner
Sheath

Cable Outer Sheath [D]


Standard
Min

Reduced (R)

Max

Min

Max

Armour
Acceptance
Range

Shroud
Size

16

M20

12

or 34

16

28.0

72.0

9.0

11.7

9.0

13.5

6.7

10.3

0.15 - 1.25

L24

20s

M20

12

or 34

16

28.0

72.0

10.4

11.7

11.5

16.0

9.4

12.5

0.15 - 1.25

L24

20

M20

12

34

16

33.0

73.0

14

12.5

14.0

15.5

21.1

12.0

17.6

0.15 - 1.25

EL30

25

M25

16

41.4

83.0

25

17.8

20.0

20.3

27.4

16.8

23.9

0.15 - 1.60

EL38

32

M32

16

50.6

103.0

50

23.5

26.3

26.7

34.0

23.2

30.5

0.15 - 2.00

EL46

40

M40

114 or 112

16

60.5

105.0

80

28.8

32.2

33.0

40.6

28.6

36.2

0.20 - 2.00

EL55

50s

M50

16

71.5

115.0

100

34.2

38.2

39.4

46.7

34.8

42.4

0.20 - 2.50

EL65

50

M50

16

71.5

115.0

100

39.4

44.1

45.7

53.2

41.1

48.5

0.20 - 2.50

EL65

63s

M63

212

19

88.0

115.0

120

44.8

50.1

52.1

59.5

47.5

54.8

0.30 - 2.50

EL80

63

M63

212

19

88.0

115.0

120

50.0

56.0

58.4

65.8

53.8

61.2

0.30 - 2.50

EL80

75s

M75

19

99.0

122.0

140

55.4

62.0

64.8

72.2

60.2

68.0

0.30 - 2.50

EL90

75

M75

19

99.0

122.0

140

60.8

68.0

71.1

78.0

66.5

73.4

0.30 - 2.50

EL90

80

M80x2

3 or

312

25

115.2

162.0

160

64.4

72.0

77.0

84.0

0.45 - 3.15

L104

85

M85x2

3 or 312

25

115.2

162.0

180

69.8

78.0

79.6

90.0

75.0

85.4

0.45 - 3.15

L104

90

M90x2

312

or 4

25

125.7

166.0

200

75.1

84.0

88.0

96.0

0.45 - 3.15

L114

100

M100x2

312 or 4

25

125.7

166.0

220

80.5

90.0

92.0

102.0

87.4

97.4

0.45 - 3.15

L114

or

34

1 or

or 1
114

All Dimensions are in mm


NOTES:
Gland Size does not necessarily equate to the entry thread size
Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
Please note that dimensions (A) & (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables

for specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of

EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and
should be achieved for tapered threads

If CR-C type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 4.1.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Type CR-X Barrier Gland For Unarmoured Cable


Part of our ATEX Gland Range
2006 Catalogue Page 4.2.0

Croclock CR-X type glands provide a Flameproof EExd compound filled barrier and an entry thread seal. Croclock CR-X
type glands maintain EExd Flameproof method of explosion protection; IP66, 68 to 100 metres and is deluge resistant.

Design Standard

EN50014:1998, EN50018:2000 & EN 50281-1-1:1998


IEC 60079-0 (2000-06), IEC 60079-1 (2001-02)

CERTIFication

ATEX I M2 II 2 GD, E Exd I & IIC


GOST R-Exd I & IICU
CSA Exd I & IIC/Exe II 4X, Class 1, Zone 1
CSA A Exd IIC/A Exe II 4X, Class 1, Zone 1
IECEx Exd IIC / Exd I
NEPSI Exd IIC / Exe II

CERTIFicate

SIRA 03ATEX1479X - Ex Notified Body No. 0518


POCC GB 05.B00974
CSA 1356011
IECEx SIR 05.0020X
NEPSI GYJ06188X

GLAND MARKING

CENELEC & ATEX

Example:
SIRA 03ATEX1479X

I M2 II 2GD EExd I & IIC IP68 PEPPERS UK / XX / CR-XB - 20S (XX = Year Code)

Exd Equipment
E
CR-X type glands will maintain Flameproof Exd integrity when used with any unarmoured cable types.

APPLICATION

Ref: IEC60079-14:2002 Section 10.4.2


Gas Group

Internal Ignition Source

Enclosure Volume

Which Zone

Use CR-X Gland

I, IIC, IIB, IIA

YES

Any

Zone 1 or 2

YES

Other Equipment
Mining Equipment Group I, M2
Ignitable Dust, Zones 21 and 22
INGRESS
PROTECTION

IP66 & IP68 @ 100 metres


Meets the requirements of DTS01 1991

CURING TIME

@ 21C
Conductor termination can be effected after 1 hour
The equipment can be energised after 4 hours
The compound chamber can be inspected after 4 hours

MATERIALS

Brass CZ121 (CR-XB)


316 Stainless Steel (CR-XS)
Inner LSOH compound
Entry thread seal: Red LSOH silicone

VARIATIONS

options

For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (CR-X2B); 316 Stainless Steel (CR-X2S)
THREADS
plating

OPERATING
TEMPERATURES

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)
Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)
-60C to +85C

2006 Catalogue Page 4.2.0

Peppers Cable Glands Limited 2006

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC)
Gland and accessory kits:
K1- includes gland, locknut, integral IP O ring & PVC shroud
Note: Glands with non metric threads are supplied with flat IP washers.

example part
number

Sample: CR-XB K1/NP/20S/M20


CR-X:
CR-X - Gland type
**-*B - Material (Brass)
K1

- Supplied complete with accessories (PVC Shroud)

NP

- Nickel plating

20s - Gland size with regards to cable acceptance range


M20 - Entry thread
Gland Size

Entry Threads

Metric

Entry Thread
Length

Max Across
Corners

[B]

[A]

Max
Protrusion
Length

NPT/BSP

Gland Seal Range


Cable Sheath / Cores

Shroud Size

Max
No. of
Cores

Max
Over
Cores [C]

Max
Sheath
Diameter [D]

20s

M20

12

or 34

16

28.0

42.0

10.4

11.7

L24

20

M20

12

or 34

16

33.0

44.0

14

12.5

14.0

L30

25

M25

or 1

16

41.4

48.0

25

17.8

20.0

L38

32

M32

1 or 114

16

50.6

53.0

50

23.5

26.3

L46

40

M40

114 or 112

16

60.5

54.0

80

28.8

32.2

L55

50

M50

16

71.5

54.0

100

39.4

44.1

L65

63

M63

212

19

88.0

55.0

120

50.0

56.0

L80

75

M75

19

99.0

60.0

140

60.8

68.0

L90

80

M80x2

3 or

312

25

115.2

80.0

160

64.4

72.0

L104

85

M85x2

3 or 312

25

115.2

80.0

180

69.8

78.0

L104

90

M90x2

312

or 4

25

125.7

85.0

200

75.1

84.0

L114

100

M100x2

312 or 4

25

125.7

85.0

220

80.5

90.0

L114

34

All Dimensions are in mm

NOTES:
Gland Size does not necessarily equate to the entry thread size
Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
Please note that dimensions (A) & (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables

for specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of

EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should
be achieved for tapered threads

If CR-X type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 4.2.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Type CR-U Barrier Gland For Unarmoured Cable


Part of our ATEX Gland Range
2006 Catalogue Page 4.2.1

Croclock CR-U type glands provide a Flameproof EExd compound filled barrier, a secondary weather seal on the outer
sheath and an entry thread seal. Croclock CR-U type glands maintain EExd Flameproof method of explosion protection;
IP66, 68 to 100 metres and is deluge resistant.

Design Standard

EN50014:1998, EN50018:2000 & EN 50281-1-1:1998


IEC 60079-0 (2000-06), IEC 60079-1 (2001-02)
ATEX I M2 II 2 GD, E Exd I & IIC
GOST R-Exd I & IICU
CSA Exd I & IIC 4X, Class 1, Zone 1
CSA A Exd IIC/A Exe II 4X, Class 1, Zone 1
IECEx Exd IIC / Exd I
NEPSI Exd IIC / Exe II

CERTIFication

CERTIFicate

SIRA 03ATEX1479X - Ex Notified Body No. 0518


POCC GB 05.B00974
CSA 1356011
IECEx SIR 05.0020X
NEPSI GYJ06188X

GLAND MARKING

CENELEC & ATEX


Example:
SIRA 03ATEX1479X

I M2 II 2GD EExd I & IIC IP68 PEPPERS UK / XX / CR-UB - 20S (XX = Year Code)

Exd Equipment
E
CR-U type glands will maintain Flameproof Exd integrity when used with any unarmoured cable types.
Ref: IEC60079-14:2002 Section 10.4.2

APPLICATION

Gas Group

Internal Ignition Source

Enclosure Volume

Which Zone

Use CR-U Gland

I, IIC, IIB, IIA

YES

Any

Zone 1 or 2

YES

Other Equipment
Mining Equipment Group I, M2
Ignitable Dust, Zones 21 and 22
INGRESS
PROTECTION

IP66 & IP68 @ 100 metres

CURING TIME

@ 21C

Meets the requirements of DTS01 1991


Conductor termination can be effected after 1 hour
The equipment can be energised after 4 hours
The compound chamber can be inspected after 4 hours

MATERIALS

Brass CZ121 (CR-UB)


316 Stainless Steel (CR-US)
Inner LSOH compound
Standard outer sheath seal is LSOH silicone, white (CR-U*)
Entry thread seal: Red LSOH silicone

VARIATIONS

options

For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (CR-U2B); 316 Stainless Steel (CR-U2S)
THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

OPERATING
TEMPERATURES

-60C to +85C

2006 Catalogue Page 4.2.1

Peppers Cable Glands Limited 2006

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC)
Gland and accessory kits:
K1- includes gland, locknut, integral IP O ring & PVC shroud
Note: Glands with non metric threads are supplied with flat IP washers.

example part
number

Sample: CR-UB K1/NP/20S/M20


CR-U:
CR-U - Gland type
**-*B - Material (Brass)
K1

- Supplied complete with accessories (PVC Shroud)

NP

- Nickel plating

20s - Gland size with regards to cable acceptance range


M20 - Entry thread
Gland
Size

Entry Threads

Metric

16

Entry
Thread
Length

Max
Across
Corners

[B]

[A]

Gland Seal Range

Max
Protrusion
Length

NPT/BSP

Cable Inner
Sheath / Cores [C]

Cable Outer
Sheath [D]

Max
No. of
Cores

Max
Over
Cores

Max
Inner
Sheath

8.4

8.4

Min

Max

3.4

8.4

Shroud
Size

M20

12

or 34

16

28.0

73.0

20s

M20

12

or

34

16

28.0

73.0

10.4

11.7

4.8

11.7

L24

20

M20

12

or 34

16

33.0

73.0

14

12.5

14.0

9.5

14.0

EL30

25

M25

34

or 1

16

41.4

74.0

25

17.8

20.0

11.7

20.0

EL38

32

M32

1 or 114

16

50.6

80.0

50

23.5

26.3

18.1

26.3

EL46

40

M40

114 or 112

16

60.5

87.0

80

28.8

32.2

22.6

32.2

EL55

50s

M50

16

71.5

87.0

100

34.2

38.2

28.2

38.2

EL65

50

M50

16

71.5

87.0

100

39.4

44.1

33.1

44.1

EL65

63s

M63

212

19

88.0

88.0

120

44.8

50.1

39.3

50.1

EL80

63

M63

212

19

88.0

88.0

120

50.0

56.0

46.7

56.0

EL80

75s

M75

19

99.0

97.0

140

55.4

62.0

52.3

62.0

EL90

75

M75

19

99.0

97.0

140

60.8

68.0

58.0

68.0

EL90

80

M80 x 2

3 or 312

25

115.2

123.0

160

64.4

72.0

61.9

72.0

L104

85

M85 x 2

3 or

312

25

115.2

123.0

180

69.8

78.0

69.1

78.0

L104

90

M90 x 2

312 or 4

25

125.7

123.0

200

75.1

84.0

74.1

84.0

L114

100

M100 x 2

312 or 4

25

125.7

123.0

220

80.5

90.0

81.8

90.0

L114

L24

All Dimensions are in mm


NOTES:
Gland Size does not necessarily equate to the entry thread size
Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
Please note that dimensions (A) & (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables

for specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of

EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should
be achieved for tapered threads

If CR-U type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 4.2.1 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Type CR-S Barrier Gland For Conduits


Part of our ATEX Gland Range
2006 Catalogue Page 4.3.0

Croclock CR-S type glands provide Flameproof EExd compound filled barrier seal on the cables individual conductors
within a conduit. It also provides an entry thread seal. Croclock CR-S type glands maintain EExd Flameproof method of
explosion protection; IP66, 68 to 100 metres and is deluge resistant.

Design Standard

EN50014:1998, EN50018:2000 & EN 50281-1-1:1998


IEC 60079-0 (2000-06), IEC 60079-1 (2001-02)
ATEX I M2 II 2 GD, E Exd I & IIC
GOST R-Exd I & IICU
CSA Exd I & IIC 4X, Class 1, Zone 1
IECEx Exd IIC / Exd I
NEPSI Exd IIC / Exe II

CERTIFication

CERTIFicate

SIRA 03ATEX1479X - Ex Notified Body No. 0518


POCC GB 05.B00974
CSA 1356011
IECEx SIR 05.0020X
NEPSI GYJ06188X

GLAND MARKING

CENELEC & ATEX


Example:
SIRA 03ATEX1479X

I M2 II 2GD EExd I & IIC IP68 PEPPERS UK/XX/CR-SB - 20 M20 M20 (XX = Year Code)

Exd Equipment
E
CR-S type glands will maintain Flameproof Exd integrity.
Ref: IEC60079-14:2002 Section 10.4.2

APPLICATION

Gas Group

Internal Ignition Source

Enclosure Volume

Which Zone

Use CR-S Gland

I, IIC, IIB, IIA

YES

Any

Zone 1 or 2

YES

Other Equipment
Mining Equipment Group I, M2
Ignitable Dust, Zones 21 and 22
INGRESS
PROTECTION

IP66 & IP68 @ 100 metres

CURING TIME

@ 21C

Meets the requirements of DTS01 1991


Conductor termination can be effected after 1 hour
The equipment can be energised after 4 hours
The compound chamber can be inspected after 4 hours

MATERIALS

Brass CZ121 (CR-SB)


316 Stainless Steel (CR-SS)
Inner LSOH compound
Entry thread seal: Red LSOH silicone

options

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

OPERATING
TEMPERATURES

-60OC to +85OC

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)

2006 Catalogue Page 4.3.0

Peppers Cable Glands Limited 2006

example part
number

Sample: CR-SB 20 /NP /M20 /M20


CR-S:
CR-S - Gland type
**-*B - Material (Brass)
20

- Fitting size = 20

NP

- Nickel plating

M20 - Male entry thread


M20 - Female thread for gland or conduit entry
Fitting
Size
Ref

Male Entry Threads

Metric

NPT

Female Entry Threads

Metric

NPT

Entry
Thread
Length

Max
Across
Corners

[B]

[A]

16

33.0

Sealing Range
Cable Conductors / Cores

Max
Protrusion
Length

Max
No. of
Cores

Max
Over
Cores [C]

14

12.5

Max Cable
Inside Fitting
[D]

20

25

M25

34

or 1

M25

34

or 1

16

41.4

63.0

25

17.8

20.0

32

M32

1 or 114

M32

1 or 114

16

50.6

67.0

50

23.5

26.3

40

M40

114 or 112

M40

114 or 112

16

60.5

68.0

80

28.8

32.2

50

M50

M50

16

71.5

68.0

100

39.4

44.1

63

M63

212

M63

212

19

88.0

72.0

120

50.0

56.0

75

M75

M75

19

99.0

78.0

140

60.8

68.0

80

M80 x 2

3 or 312

M80 x 2

3 or 312

25

115.2

103.0

160

64.4

72.0

85

M85 x 2

3 or 312

M85 x 2

3 or 312

25

115.2

103.0

180

69.8

78.0

90

M90 x 2

312 or 4

M90 x 2

312 or 4

25

125.7

104.0

200

75.1

84.0

100

M100 x 2

312 or 4

M100 x 2

312 or 4

25

125.7

104.0

220

80.5

90.0

M20

12

or 34

M20

12

or 34

57.0

14.0

All Dimensions are in mm


NOTES:
Please note that dimensions (A) & (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables

for specific dimensions

Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of

EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should
be achieved for tapered threads

If CR-S type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation
To maintain ingress protection a thread sealant should be applied to the conduit thread
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 4.3.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

CROCLOCK: Type UL-C


Part of our UL Range
2006 Catalogue Page 4.4.0
UL-C Type Explosion-proof glands featuring Croclock, provide a compound seal preventing the passage of gas or
vapours through the gland and the propagation of flame into the cable core. The glands are UL listed; suitable for
Marine Shipboard Jacketed or non-Jacketed cable; NEMA 4X applications and are Deluge-Proof.

Design Standard

UL2225 & UL514B

CERTIFication

CLASS I, DIVISION 1

GAS GROUPS ABCD


File No. E248936

CERTIFicate

GLAND MARKING

Example:
UL-CBR 20 1/2 NPT
PEPPERS GU15 3BT UK
CL I DIV 1 ABCD
-25+85C 4X

LISTED APPLICATION

Class I, Division 1 ABCD


Croclock UL-C type glands will maintain the Explosion-Proof integrity of electrical equipment when used with
suitable listed cable types.
NEC 505:
Class I, Zone 1, Gas Groups IIC, IIB, IIA. Croclock UL-C type glands will maintain the Flameproof integrity of
electrical equipment when used with suitable listed cable types.

INGRESS
PROTECTION

NEMA 4X. Meets the requirements of DTS01 1991 and IP66

CURING TIME

@21C
Conductor termination can be effected after 1 hour
The equipment can be energised after 4 hours

MATERIALS

Brass CZ121 (UL-CB)


Stainless Steel 316 (UL-CS)
Inner LSOH compound
Standard outer sheath seal is LSOH silicone, white
Reduced bore outer sheath seal is LSOH silicone, red (UL-C*R)

options

THREADS

ISO Metric; NPT; NPSM

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN) - All entry threads are nickel plated as standard

OPERATING
TEMPERATURES

-25C to +85C

2006 Catalogue Page 4.4.0

Peppers Cable Glands Limited 2006

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC)

example part
number

Sample: UL-CBR / 20 / 050NPT


UL-C UL-*B UL-**R 20
050NPT -

Gland
Size

Entry Threads

Gland type, armour type (SWA) and body material (Brass)


Material (Brass)
Reduced bore outer seal
Fitting size = 20
NPT entry thread

Entry
Thread
Length
[B]

Metric

NPT

Max
Max
Across Protrusion
Corners
Length

Gland Seal Range

[A]

Max
Inner
Sheath

NPT

Armour Acceptance
Range

Cable Outer Sheath [D]

Cable Inner
Sheath [C]

Standard
Min

Max

Shroud
Size

Reduced (R)
Min

Max

16

M20

12

or 34

0.783

1.102

2.835 0.461

0.362

0.531

0.264

0.406 0.006-0.049

L24

20s

M20

12

or 34

0.783

1.102

2.835 0.461

0.453

0.630

0.370

0.492

0.006-0.049

L24

12

34

20

M20

25

M25

or

34

1 or

or 1
114

0.783

1.299

2.874 0.551

0.610

0.831

0.563

0.693

0.006-0.049

EL30

0.795

1.630

3.268 0.787

0.799

1.079

0.689

0.941

0.006-0.063

EL38

32

M32

40

M40

50s

M50

1.059

2.815

4.528 1.504

50

M50

1.059

2.815

4.528 1.736

1.571

4.528 1.972

1.571

4.528 2.205

114 or 112

0.985

1.992

4.055 1.035

1.051

1.339

0.984

1.201

0.006-0.079

EL46

1.008

2.382

4.134 1.268

1.299

1.598

1.154

1.425

0.008-0.079

EL55

1.551

1.839

1.499

1.669

0.008-0.098

EL65

1.799

2.094

1.618

1.909 0.008-0.098

EL65

2.051

2.343

1.846

2.157

0.012-0.098

EL80

2.299

2.591

2.118

2.409

0.012-0.098

EL80

63s

M63

212

63

M63

212

75s

M75

1.634

4.803 2.441

2.551

2.843

2.469

2.677

0.012-0.098

EL104

75

M75

1.634

4.803 2.677

2.799

3.071

2.618

2.890

0.012-0.098

EL104

All Dimensions are in inches


All Dimensions are in Millimetres
NOTES:

Gland Size does not necessarily equate to the entry thread size

Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required

Please note that dimensions (A) and (B) may differ for glands with parallel entry threads. Please refer to our thread data tables for
specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

For Class I Group A locations, the joint made by fitting the gland to the enclosure female thread must comply with standard UL 886
clause 6.1 as follows:-

NPT threads must have at least five threads fully engaged


Metric and NPS threads must have at least eight threads fully engaged

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 4.4.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Type UL-X
Part of our UL Range
2006 Catalogue Page 4.5.0
UL-X Type Explosion-proof glands provide a compound seal preventing the passage of gas or vapours through the gland
and the propagation of flame into the cable core. The glands are UL listed; suitable for Marine Shipboard non-armoured
cable; NEMA 4X applications and are Deluge-Proof.

Design Standard

UL2225 & UL514B


CLASS I, DIVISION 2

CERTIFication

GAS GROUPS ABCD


CERTIFicate

File No. E248936

GLAND MARKING

Example:
UL-XB 20 1/2 NPT
PEPPERS GU15 3BT UK
CL I DIV 1 ABCD
-25+85C 4X

LISTED APPLICATION

Class I, Division 2 ABCD


UL-X type glands will maintain the Explosion-Proof integrity of electrical equipment when used with suitable listed
cable types.
NEC 505:
Class I, Zone 2, Gas Groups IIC, IIB, IIA. UL-X type glands will maintain the Flameproof integrity of electrical
equipment when used with suitable listed cable types.

INGRESS
PROTECTION

NEMA 4X. Meets the requirements of DTS01 1991

CURING TIME

@21C
Conductor termination can be effected after 1 hour
The equipment can be energised after 4 hours

MATERIALS

Brass CZ121 (UL-XB)


Stainless Steel 316 (UL-XS)
Inner LSOH compound

options

THREADS

ISO Metric; NPT; NPSM

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN) - All entry threads are nickel plated as standard

OPERATING
TEMPERATURES

-25C to +85C

2006 Catalogue Page 4.5.0

Peppers Cable Glands Limited 2006

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC)

example part
number

Sample: UL-XB / 20 / 050NPT


UL-X UL-*B 20
050NPT -

Gland
Size

Trade Size

Gland type
Material (Brass)
Fitting size = 20
NPT entry thread

Entry
Thread
Length
[B]

Metric

NPT

Max
Max
Across Protrusion
Corners
Length

Maximum Sheath
Diameter [C]

Shroud
Size

[A]

NPT

20s

M20

12

or 34

0.783

1.102

1.654

0.461

L24

20

M20

12

or 34

0.783

1.299

1.732

0.551

L30

25

M25

34

or 1

0.795

1.630

1.890

0.787

L38

32

M32

1 or 114

0.985

1.992

2.087

1.035

L46

114

112

40

M40

50

M50

63

M63

212

1.571

75

M75

1.634

or

1.008

2.382

2.126

1.268

L55

1.059

2.815

2.126

1.736

L65

3.465

2.165

4.134

2.362

2.205

L80

2.677

L90

All Dimensions are in inches

NOTES:

Gland Size does not necessarily equate to the entry thread size

Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required

Please note that dimensions (A) and (B) may differ for glands with parallel entry threads. Please refer to our thread data tables for
specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

For Class I Group A locations, the joint made by fitting the gland to the enclosure female thread must comply with standard UL 886
clause 6.4.1 as follows:-

NPT threads must have at least five threads fully engaged


Metric and NPS threads must have at least eight threads fully engaged

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 4.5.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Type UL-U
Part of our UL Range
2006 Catalogue Page 4.5.1
UL-U Type Explosion-proof glands featuring provide a compound seal preventing the passage of gas or vapours through
the gland and the propagation of flame into the cable core. The glands are UL listed; suitable for Marine Shipboard
non-armoured cable; NEMA 4X applications and are Deluge-Proof.

Design Standard

UL2225 & UL514B

CERTIFication

CLASS I, DIVISION 2
GAS GROUPS ABCD

CERTIFicate

File No. E248936

GLAND MARKING

Example:
UL-UB 20 1/2 NPT
PEPPERS GU15 3BT UK
CL I DIV 1 ABCD
-25+85C 4X

LISTED APPLICATION

Class I, Division 2 ABCD


UL-U type glands will maintain the Explosion-Proof integrity of electrical equipment when used with suitable listed
cable types.
NEC 505:
Class I, Zone 2, Gas Groups IIC, IIB, IIA. UL-U type glands will maintain the Flameproof integrity of electrical
equipment when used with suitable listed cable types.

INGRESS
PROTECTION

NEMA 4X. Meets the requirements of DTS01 1991

CURING TIME

@21C
Conductor termination can be effected after 1 hour
The equipment can be energised after 4 hours

MATERIALS

Brass CZ121 (UL-UB)


Stainless Steel 316 (UL-US)
Inner LSOH compound
Standard outer sheath seal is LSOH silicone, white

options

THREADS

ISO Metric; NPT; NPSM

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN) - All entry threads are nickel plated as standard

OPERATING
TEMPERATURES

-25C to +85C

2006 Catalogue Page 4.5.1

Peppers Cable Glands Limited 2006

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC)

example part
number

Sample: UL-UB / 20 / 050NPT


UL-U UL-*B 20
050NPT -

Gland
Size

Entry Threads

Gland type
Material (Brass)
Fitting size = 20
NPT entry thread

Entry
Thread
Length
[B]

Metric

NPT

Max
Max
Across Protrusion
Corners
Length

Gland Seal Range


Cable Inner
Sheath [C]

[A]

NPT

Shroud
Size

Cable Outer Sheath [D]

Max
Inner
Sheath

Min

Max

16

M20

12

or 34

0.783

1.102

2.835

0.461

0.134

0.331

L24

20s

M20

12

or 34

0.783

1.102

2.835

0.461

0.189

0.461

L24

12

34

20

M20

25

M25

34

32

M32

1 or 114

0.985

1.992

4.055

1.035

0.713

1.035

EL46

40

M40

114 or 112

1.008

2.382

4.134

1.268

0.890

1.268

EL55

50s

M50

1.059

2.815

4.528

1.504

1.110

1.504

EL65

50

M50

1.059

2.815

4.528

1.736

1.303

1.736

EL65

1.571

3.465

4.528

1.972

1.547

1.972

EL80

1.571

3.465

4.528

2.205

1.839

2.205

EL80

or

or 1

0.783

1.299

2.874

0.551

0.374

0.551

EL30

0.795

1.630

3.268

0.787

0.461

0.787

EL38

63s

M63

212

63

M63

212

75s

M75

1.634

4.134

4.803

2.441

2.059

2.441

EL104

75

M75

1.634

4.134

4.803

2.677

2.283

2.677

EL104

All Dimensions are in inches

NOTES:

Gland Size does not necessarily equate to the entry thread size

Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required

Please note that dimensions (A) and (B) may differ for glands with parallel entry threads. Please refer to our thread data tables for
specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full

For Class I Group A locations, the joint made by fitting the gland to the enclosure female thread must comply with standard UL 886
clause 6.4.1 as follows:-

NPT threads must have at least five threads fully engaged


Metric and NPS threads must have at least eight threads fully engaged

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 4.5.1 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Cable Gland:- Type BW


Part of our Industrial Gland Range
2006 Catalogue Page 5.1.0
BW type glands provide an integral armour clamp for armoured cable. The integral armour clamp provides an electrical
bond between the cable armour and the gland. BW type glands maintain IP30.

Design Standard

BS 6121:1989

GLAND MARKING

Example:
BS6121 Part 1 BW [size] [thread] PCGL (or
PEPPERS)

INGRESS
PROTECTION

IP30

MATERIALS

Brass CZ121 (BW)

VARIATIONS

All variants of the BW type gland feature a separate armour clamping ring to allow for inspection of the clamped
armour:Brass (BWL)
Integral Earth version for HV applications:
Brass (BWLIE)

OPERATING
TEMPERATURES
options

-100OC to +600OC

THREADS

ISO Metric only

CLAMPS

SWA Clamping using gland body (BW)


SWA steel wire armour - clamping ring (BWL)
SWB woven steel wire armour or STA steel tape armour - clamping ring (BXL/BZL)

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

accessories

Locknut - Brass (ACBLN); Steel (ACMLN)


Earth Tag - Brass (ACBET)
Shroud - PVC (ACSPVC)
Gland and accessory kits:
K1- includes gland, steel locknut, earthtag and PVC shroud

example part
number

Sample: BW K1/ZP/20S/M20
BW:
BW K1 ZP 20s M20 -

2006 Catalogue Page 5.1.0

Gland type, armour type (SWA) and body material (Brass)


Supplied complete with accessories (PVC Shroud)
Zinc plating
Gland size with regards to cable acceptance range
Entry thread

Peppers Cable Glands Limited 2006

Gland
Size

Entry
Threads

Entry
Thread
Length

Max
Across
Corners

Metric

[B]

[A]

Gland Seal Range

Max
Protrusion
Length

Cable Outer
Sheath [D]

Cable Inner
Sheath [C]

Min

Max

Min

Max

Armour Acceptance
Range

Shroud
Size

XZ
Clamp Ring
Version Only

20s

M20

10

24.2

20.0

11.7

16.0

0.90-1.25

0.15-0.35

S22

20

M20

10

29.7

20.0

14.0

21.0

0.90-1.25

0.15-0.50

S27

25

M25

10

45.1

22.0

20.0

27.4

1.25-1.60

0.15-0.50

S36

32

M32

10

50.6

25.0

26.3

34.0

1.60-2.00

0.15-0.55

S41

40

M40

15

60.5

30.0

32.2

40.6

1.60-2.00

0.20-0.60

L55

50

M50

15

71.5

32.0

44.1

53.2

2.00-2.50

0.20-0.60

L65

63

M63

15

88.0

42.0

56.0

65.8

2.50

0.30-0.80

L80

75

M75

15

99.0

50.0

68.0

78.0

2.50

0.30-1.00

L90

80

M80

20

115.2

50.0

72.0

84.0

3.15

0.45-1.00

S104

85

M85

20

115.2

50.0

78.0

90.0

3.15

0.45-1.00

S104

90

M90

20

125.7

50.0

84.0

96.0

3.15

0.45-1.00

S114

100

M100

20

125.7

50.0

90.0

102.0

-3.15

0.45-1.00

S114

All Dimensions are in Millimetres

NOTES:

Gland Size does not necessarily equate to the entry thread size

"W" refers to the wire diameter in a steel wire armoured cable

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

Shroud sizes above are for type BW only

Full assembly instructions are available upon request, the instructions should be read prior to installation and adhered to in full

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 5.1.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Cable Gland:- Type CWL


Part of our Industrial Gland Range
2006 Catalogue Page 5.2.0
CWL type glands provide a seal on the outer sheath and an armour specific armour clamp for armoured cable. The
armour clamp provides an electrical bond between the cable armour and the gland. CWL type glands maintain IP66.

Design Standard

BS EN 50262: 1999

GLAND MARKING

Example:
CWL [size] [thread] PCGL (or Peppers)

INGRESS
PROTECTION

IP66

MATERIALS

Brass CZ121 (CWL)


316 Stainless Steel (CWLS)
Outer sheath seal material: Standard (C)
Neoprene, black. Option (C3) Silicone, white.
Reduced bore outer sheath seal (R) Silicone,
red. (CWLR)

VARIATIONS

options

Integral Earth version for HV applications:


Brass (CWLIE); 316 Stainless Steel (CWLSIE)
THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

Seals

Extended operating temperature -60C to +180C, halogen free versions:


Brass (C3WL); 316 Stainless Steel (C3WLS)

CLAMPS

SWA steel wire armour (CWL)


SWB woven steel wire armour or STA steel tape armour (CXZL)

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

OPERATING
TEMPERATURES

Standard Seals -20C to +85C


Silicone Seals -60C to +180C

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN); Aluminium (ACALN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET); Aluminium (ACAET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC); PCP (ACSPCP); Low Smoke Zero Halogen (ACSSIO)
Gland and accessory kits:
K1- includes gland, locknut, earthtag and PVC shroud
C3WLK1 - includes brass gland, brass locknut, brass earthtag and zero halogen shroud

example part
number

Sample: CWL R K1/ZP/20S/M20


CWL:
CWL - Gland type, seal material, armour type (SWA) and body material (Brass)
C3WL - Seal material (Silicone)
R
K1
ZP
20s
M20

2006 Catalogue Page 5.2.0

Reduced bore outer seal


Supplied complete with accessories (PVC Shroud)
Zinc plating
Gland size with regards to cable acceptance range
Entry thread

Peppers Cable Glands Limited 2006

Gland
Size

Entry Threads

Max
Entry
Max
Thread Across Protrusion
Length Corners Length
[B]

Metric

16

[A]

Gland Seal Range

Min Max

Armour Acceptance
Range

Cable Outer Sheath [D]

Cable Inner
Sheath [C]

Standard
Min

Max

Shroud
Size

Reduced (R)
Min

Max

XZ

10.3

0.90

0.15-0.35

L24

NPT/BSP

M20

12

or 34

16

26.5

54.0

8.4

9.0

13.5

or

34

16

26.5

54.0

11.7

11.5

16.0

9.4

12.5

0.90-1.25

0.15-0.35

L24

or 34

16

33.0

54.0

14.0

15.5

21.0

12.0

17.6

0.90-1.25

0.15-0.50

L30

20s

M20

12

20

M20

12

6.7

25

M25

34

or 1

16

41.4

54.0

20.0

20.3

27.4

16.8

23.9

1.25-1.60

0.15-0.50

L38

32

M32

1 or 114

16

50.6

60.0

26.3

26.7

34.0

23.2

30.5

1.60-2.00

0.15-0.55

L46

40

M40

50s

M50

50

63s

63

114

16

60.5

67.0

32.2

33.0

40.6

28.6

36.2

1.60-2.00

0.20-0.60

L55

112 or 2

16

71.5

67.0

38.2

39.4

46.7

34.8

42.4

2.00-2.50

0.20-0.60

L65

M50

16

71.5

67.0

44.1

45.7

53.2

41.1

48.5

2.00-2.50

0.30-0.60

L65

M63

2 or 212

19

88.0

69.0

50.1

52.1

59.4

47.5

54.8

2.50

0.30-0.80

L80

M63

212

19

88.0

69.0

56.0

58.4

65.8

53.8

61.2

2.50

0.30-0.80

L80

75s

M75

75

M75

or

112

212

or 3

19

99.0

77.0

62.0

64.8

72.2

60.2

68.0

2.50

0.30-1.00

L90

19

99.0

77.0

68.0

71.1

78.0

66.5

73.4

2.50

0.30-1.00

L90

312

25

115.2

104.0

72.0

77.0

84.0

3.15

0.45-1.00

L104

25

115.2

104.0

72.0

79.6

90.0

3.15

0.45-1.00

L104

80

M80 x 2

3 or

80H

M80 x 2

3 or 312
312

85

M85 x 2

3 or

25

115.2

104.0

78.0

79.6

90.0

75.0

85.4

3.15

0.45-1.00

L104

90

M90 x 2

312 or 4

25

125.7

104.0

84.0

88.0

96.0

3.15

0.45-1.00

L114

90H

M90 x 2

312 or 4

25

125.7

104.0

84.0

92.0

102.0

3.15

0.45-1.00

L114

100

M100 x 2

312 or 4

25

125.7

104.0

90.0

92.0

102.0

87.4

97.4

3.15

0.45-1.00

L114

All Dimensions are in Millimetres


NOTES:

Gland Size does not necessarily equate to the entry thread size

"W" refers to the wire diameter in a steel wire armoured cable

"XZ" refers to the wire diameter in a woven steel wire armoured cable or the tape thickness in a steel tape armoured cable

Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

Full assembly instructions are available upon request, the instructions should be read prior to installation and adhered to in full

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 5.2.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Cable Gland:- Type E1W


Part of our Industrial Gland Range
2006 Catalogue Page 5.3.0
E1W type glands provide a seal on the inner sheath, a seal on the outer sheath and an armour specific armour clamp
for armoured cable. The armour clamp provides an electrical bond between the cable armour and the gland. E1W type
glands maintain IP66, IP67.

Design Standard

BS EN 50262: 1999

GLAND MARKING

Example:

E1W [size] [thread] PCGL (or Peppers)


INGRESS
PROTECTION

IP66 and IP67

MATERIALS

Brass CZ121 (E1W)


316 Stainless Steel (E1WS)

Inner & outer sheath seal material: Standard (E1)


Neoprene, black. Option (E3) Silicone, white.
Reduced bore outer sheath seal (R) Silicone, red.
(E1WFR)
VARIATIONS

For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (E2W); 316 Stainless Steel (E2WS)
Integral earth version for HV appliances:
Brass (E1WIE); 316 Stainless Steel (E1WIES)
Omission of outer seal:
Brass (D1W); 316 Stainless Steel (D1WS)

options

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

Seals

Extended operating temperature -60C to +180C, halogen free versions:


Brass (E3W); 316 Stainless Steel (E3WS)

CLAMPS

SWA steel wire armour (E1W)


SWB woven steel wire armour (E1X)
STA steel tape armour (E1Z)

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

OPERATING
TEMPERATURES

Standard Seals -20C to +85C


Silicone Seals -60C to +200C

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN); Aluminium (ACALN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET); Aluminium (ACAET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC); PCP (ACSPCP); Low Smoke Zero Halogen (ACSSIO)
Gland and accessory kits:
K1 - includes gland, locknut, earthtag and PVC shroud
E3WK1 - includes brass gland, brass locknut, brass earthtag and zero halogen shroud

2006 Catalogue Page 5.3.0

Peppers Cable Glands Limited 2006

example part
number

Sample: E1W R K1/ZP/20S/M20


E1W:
E*W - Gland type, armour type (SWA) and body material (Brass)
*1* - Seal material (Neoprene)
R K1 ZP 20s M20 -

Gland
Size

Reduced bore outer seal


Supplied complete with accessories (PVC Shroud)
Zinc plating
Gland size with regards to cable acceptance range
Entry thread

Entry Threads

Entry
Max
Max
Thread Across Protrusion
Length Corners Length
[B]

Metric

16

[A]

Gland Seal Range

Min Max

Armour Acceptance
Range

Cable Outer Sheath [D]

Cable Inner
Sheath [C]

Standard
Min

Max

Reduced (R)
Min

Max

Shroud
Size

XZ

10.0

0.90

0.15-0.35

L24

NPT/BSP

M20

12

or 34

16

26.5

58.0

4.0

8.4

8.4

13.5

or

34

16

26.5

58.0

8.0

11.7

11.5

16.0

9.4

12.5

0.90-1.25

0.15-0.35

L24

or 34

16

33.0

58.0

6.7

14.0

15.5

21.0

12.0

17.6

0.90-1.25

0.15-0.50

L30

20s

M20

12

20

M20

12

4.9

25

M25

34

or 1

16

41.4

58.0

13.0

20.0

20.3

27.4

16.8

23.9

1.25-1.60

0.15-0.50

L38

32

M32

1 or 114

16

50.6

65.0

19.0

26.3

26.7

34.0

23.2

30.5

1.60-2.00

0.15-0.55

L46

40

M40

50s

M50

50

63s

114

or

112

16

60.5

72.0

25.0

32.2

33.0

40.6

28.6

36.2

1.60-2.00

0.20-0.60

L55

112 or 2

16

71.5

73.0

31.5

38.2

39.4

46.7

34.8

42.4

2.00-2.50

0.20-0.60

L65

M50

16

71.5

73.0

36.5

44.1

45.7

53.2

41.1

48.5

2.00-2.50

0.30-0.80

L65

M63

2 or 212

19

88.0

76.0

42.5

50.1

52.1

59.4

47.5

54.8

2.50

0.30-0.80

L80

63

M63

212

19

88.0

76.0

49.5

56.0

58.4

65.8

53.8

61.2

2.50

0.30-0.80

L80

75s

M75

212 or 3

19

99.0

82.0

54.5

62.0

64.8

72.2

60.2

68.0

2.50

0.30-1.00

L90

75

M75

19

99.0

82.0

60.5

68.0

71.1

78.0

66.5

73.4

2.50

0.30-1.00

L90

80

M80 x 2

3 or 312

25

115.2

110.0

62.2

72.0

77.0

84.0

3.15

0.45-1.00

L104

80H

M80 x 2

3 or 312

25

115.2

110.0

62.2

72.0

79.6

90.0

3.15

0.45-1.00

L104

85

M85 x 2

3 or 312

25

115.2

110.0

69.0

78.0

79.6

90.0

75.0

85.4

3.15

0.45-1.00

L104

90

M90 x 2

312

or 4

25

125.7

110.0

74.0

84.0

88.0

96.0

3.15

0.45-1.00

L114

90H

M90 x 2

312 or 4

25

125.7

110.0

74.0

84.0

92.0

102.0

3.15

0.45-1.00

L114

100

M100 x 2

312 or 4

25

125.7

110.0

82.0

90.0

92.0

102.0

87.4

97.4

3.15

0.45-1.00

L114

All Dimensions are in Millimetres

NOTES:

Gland Size does not necessarily equate to the entry thread size

"W" refers to the wire diameter in a steel wire armoured cable

"XZ" refers to the wire diameter in a woven steel wire armoured cable or the tape thickness in a steel tape armoured cable

E3* gland size 20, the silicone inner seal only seals to a minimum of 11.0mm and NOT 6.7mm

Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

Full assembly instructions are available upon requests, the instructions should be read prior to installation and adhered to in full

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 5.3.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Cable Gland:- Type A2L


Part of our Industrial Gland Range
2006 Catalogue Page 6.1.0
A2L type glands provide a single pull resistant seal on the outer sheath of unarmoured cable. A2L type glands maintain
IP66, IP68 to 25 metres.

Design Standard

BS EN 50262: 1999

GLAND MARKING

Example:

A2L [size] [thread] PCGL (or Peppers)


INGRESS
PROTECTION

IP66 and IP68 @ 25 metres

MATERIALS

Brass CZ121 (A2L)


316 Stainless Steel (A2LS)
Aluminium Alloy (A2LA)

Outer sheath seal material:


Standard (A2L) Neoprene, black.
Option (A3L) Silicone, white.
VARIATIONS

options

For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (A4L); 316 Stainless Steel (A4LS)
THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

Seals

Extended operating temperature -60C to +180C, halogen free versions:


Brass (A4L); 316 Stainless Steel (A4LS)

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

OPERATING
TEMPERATURES

Standard Seals -20C to +85C


Silicone Seals - 60C to +200C

accessories

Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN); Aluminium (ACALN)


Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET); Aluminium (ACAET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC); PCP (ACSPCP); Low Smoke Zero Halogen (ACSSIO)
Gland and accessory kits:
K1 - includes gland, locknut and PVC shroud

example part
number

Sample: A2L K1/ZP/20S/M20


A2L:
A*L *2* K1 ZP 20s M20 -

2006 Catalogue Page 6.1.0

Gland type and body material (Brass)


Seal material (Neoprene)
Supplied complete with accessories (PVC Shroud)
Zinc plating
Gland size with regards to cable acceptance range
Entry thread

Peppers Cable Glands Limited 2006

Gland
Size

Entry Threads

Metric

16

Entry
Thread
Length

Max
Across
Corners

[B]

[A]

16

28.0

116
16

Gland Seal Range


Cable Outer/Lead Sheath [D]

Max
Protrusion
Length

Shroud
Size

Min

Max

33.0

4.0

8.4

L24

28.0

33.0

7.2

11.7

L24

33.0

33.0

9.6

14.0

L30

NPT/BSP

M20

12

or 34
or

34

or 34

20s

M20

12

20

M20

12

25

M25

34

or 1

16

41.4

33.0

13.5

20.0

L38

32

M32

1 or 114

16

50.6

33.0

19.5

26.3

L46

40

M40

114 or 112

16

60.5

37.0

23.0

32.2

L55

50s

M50

112 or 2

16

71.5

37.0

28.2

38.2

L65

50

M50

16

71.5

37.0

33.2

44.1

L65

63s

M63

2 or 212

19

88.0

37.0

39.3

50.1

L80

M63

212

19

88.0

37.0

46.7

56.0

L80

63

212

75s

M75

19

99.0

37.0

52.3

62.0

L90

75

M75

19

99.0

37.0

58.1

68.0

L90

80

M80 x 2

3 or 312

25

115.2

50.0

62.3

72.0

L104

85

M85 x 2

3 or 312

25

115.2

50.0

69.1

78.0

L104

or 3

90

M90 x 2

312

or 4

25

125.7

50.0

74.1

84.0

L114

100

M100 x 2

312 or 4

25

125.7

50.0

82.0

90.0

L114

All Dimensions are in Millimetres


NOTES:

Gland Size does not necessarily equate to the entry thread size

Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

Full assembly instructions are avalable upon request, the instructions should be read prior to installation and adhered to in full

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 6.1.0 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Accessories:- Adaptors and Reducers - Type AR


Part of our Accessories Range
2006 Catalogue Page 7.1.1
AR Series Dual Certified Adaptors and Reducers provide a method of matching electrical thread forms on Ex equipment
while maintaining Flameproof Exd and Increased Safety Exe methods of explosion protection and IP66, 68 for IEC type
applications. Class I, Division 1 and NEMA 4X, 6P for NEC/CEC type applications.

CERTIFication

CENELEC
SIRA00ATEX1094 (Metric Female)
SIRA99ATEX1115U (Non-Metric Female)
I M2 II 2DG E Ex de IandIIC
II 2DG E Ex de IIC (Aluminium)
CSA / A Ex
Class I, Zone 1, Ex de IandIIC
Class I, Division 1and2 ABCD
Class II EFG, Class III
GOST R-Exde IICU
POCC GB 05.B00482
IECEx Ex d IIC / Ex e II / Ex d I
IECEx SIR 05.0042U

INGRESS
PROTECTION

IP66 68, CSA Enclosure Type (NEMA) 4X 6P

IMPACT RESISTANCE

20Nm (7Nm Aluminium)

OPERATING
TEMPERATURES

-50C to +85C

MATERIALS

Brass CZ121 (ARB)


316 Stainless Steel (ARS)
Aluminium Alloy (ARA)

THREADS

ISO Metric; ET; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

Seals

The standard O Ring material is Nitrile


Tapered male thread options are not normally supplied c/w O ring seal, thread sealant should be used to
maintain the desired level of ingress protection

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

example part
number

Sample: ARB/NP/M20/050NPT
AR - Adapter/Reducer type
B
NP
M20
050NPT

2006 Catalogue Page 7.1.1

Body material (Brass)


Nickel plating
Male thread size
Female thread size (12 NPT)

Peppers Cable Glands Limited 2006

AVAILABLE THREAD SIZES AND CORRESPONDING BORE SIZE


Metric

M16

Bore

NPT

Bore

ISO Pipe

Bore

ET

Bore

10.0

M20

14.0

12

M25

18.0

34

15.0

12

19.0

34

PG

Bore

8.0

15.0

34

14.0

10.0

19.0

18.0

11

13.5

24.0

13.5

14.0

32.0

16

16.0

M32

24.0

25.0

25.0

114

M40

32.0

114

32.0

114

32.0

112

M50

41.0

112

38.0

112

38.0

41.0

21

21.0

M63

53.0

49.0

49.0

212

53.0

29

29.0

M75

64.0

212

60.0

212

60.0

64.0

M80 x 2.0

69.0

75.0

88.0

312

100.0

M85 x 2.0

73.0

312

M90 x 2.0

78.0

M100 x 2.0

36

38.0

75.0

42

45.0

88.0

48

50.0

100.0

88.0
All Dimensions are in Millimetres

NOTES:

Full installation instructions are supplied with adaptors and reducers, the instructions must be read prior to installation and
adhered to in full

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

For Flameproof Exd applications the female thread into which the adaptor or reducer is to be fitted must comply with clause 5.3 of
EN 50018:2000 (clause 5.3 IEC 79-1)

For NEC/CEC Explosion Proof applications an engagement of at least 8 full threads must be achieved for parallel threads and 5 full
threads must be achieved for tapered threads

Where AR adaptors and reducers are fitted into non-metallic Increased Safety Exe enclosures they must be included within the
earth circuit of the system

316 Stainless Steel versions do not feature a marking band. This reduces the overall length of reducers by 5mm, it does not affect
the overall length of Adaptors

Adaptors are used where the thread size of the cable gland or connection device is larger than, or of an equivalent size to the
entry thread of the enclosure

Reducers are used to reduce the entry thread of an enclosure to accept a cable gland or connection device with a smaller thread

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 7.1.1 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Accessories:- Nylon Adaptors and Reducers - Type ARN


Part of our Accessories Range
2006 Catalogue Page 7.1.2
ARN Series Certified Adaptors and Reducers provide a method of matching electrical threadforms on Ex equipment while
maintaining Increased Safety Exe methods of explosion protection and IP66, 68 for IEC type applications.
Adaptors are used where the thread size of the cable gland or connection device is larger than, or of an equivalent size
to the entry thread of the enclosure.
Reducers are used to reduce the entry thread of an enclosure to accept a cable gland or connection device with a
smaller thread.
CERTIFication

CENELEC
SIRA00ATEX3091 (Metric Female)
SIRA99ATEX3116U (Non-Metric Female)
II 2DG E Ex e II
CSA / A Ex
Class I, Zone 1, Ex e II
Class I, Division 2 ABCD
Class II EFG, Class III

INGRESS
PROTECTION

IP66 68, CSA Enclosure Type (NEMA) 4X 6P

IMPACT RESISTANCE

7Nm

OPERATING
TEMPERATURES

-50C to +85C

MATERIALS

30% Glass Filled Nylon (ARN)

THREADS

ISO Metric; ET; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

Seals

The standard O Ring material is Nitrile

example part
number

Sample: ARN/M20/M25
ARN - Body material (Nylon)
M20 - Male thread size
M25 - Female thread size
AVAILABLE THREAD SIZES AND CORRESPONDING BORE SIZE

Metric

Bore

NPT

Bore

ISO Pipe

Bore

ET

Bore

PG

Bore

M16

9.3 9 9.0

M20

11.0

12

12.0

12

12.0

34

11.0

11

10.0

M25

16.0

34

13.0

34

13.0

16.0

13.5

11.5

M32

21.0

18.0

18.0

114

21.0

16

13.5

M40

31.0

114

33.0

114

33.0

112

31.0

21

19.0

40.0

112

38.0

112

38.0

40.0

M50

29

28.0

36

37.0

42

44.0

All Dimensions are in Millimetres


NOTES:

Full installation instructions are supplied with adaptors and reducers, the instructions must be read prior to installation and
adhered to in full

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

Adaptors are used where the thread size of the cable gland or connection device is larger than, or of an equivalent size to the
entry thread of the enclosure

Reducers are used to reduce the entry thread of an enclosure to accept a cable gland or connection device with a smaller thread

2006 Catalogue Page 7.1.2

Peppers Cable Glands Limited 2006

http://www.cableglands.com

Peppers Cable Glands Limited 2006

Page 7.1.2 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Accessories:- Insulating Adaptors - Type IA


Part of our Accessories Range
2006 Catalogue Page 7.1.3
IA series Insulated Adaptors provide a method of insulating the cable gland or connection device from the equipment
into which it has been installed. IA series Insulated Adaptors maintain Flameproof Exd method of explosion protection
and IP66, 68 for IEC type applications. Class I, Division 2 and NEMA 3, 6P for NEC/CEC type applications.

CERTIFication

CENELEC
SIRA00ATEX1098 (Metric Female)
SIRA99ATEX1117U (Non-Metric Female)
II 2DG E Ex d IIC
CSA / A Ex
Class I, Zone 1, Ex d IIC
Class I, Division 2 ABCD
Class II EFG, Class III
GOST R-Exde IICY
POCC GB 05.B00482

APPLICATIONS

To avoid relying on the contact between cable termination and equipment enclosure for grounding the cable
armour, an insulated adaptor can be fitted to both ends of the cable with a grounding device (i.e. earth tag/lug)
fitted between the adaptor and the termination. The armour current can then be taken from the grounding device
to ground in a controlled, positive manner that can be inspected easily.
Single Point Grounding:- In many applications it is sufficient to ground the cable armour at one end. For single point grounding the
insulated adaptors would again be used at both ends of the cable but with the earth tag fitted only to the end
where grounding is required.
Single Point Grounding can:- reduce the circulating currents that can cause heating of high capacity cables.
- reduce the risk of damage to electronic equipment within the enclosure in the event of a short circuit to ground
through the enclosure.
- reduce the problems of electrical noise on the armour affecting the clean earth required for some sensitive
instruments.
Electrical properties of insulating material
- Dielectric strength: 90KV/mm
- Volume resistivity: 8.6 x 10x14 O/cm
- Minimum thickness of insulator: 5mm +/- 1mm
- 2KV Wet Withstand Tested

INGRESS
PROTECTION

IP54, CSA Enclosure Type (NEMA) 3


IP66 68 can be maintained with the use of either IP washers or a non-hardening thread sealant

IMPACT RESISTANCE

7Nm

OPERATING
TEMPERATURES

-20C to +60C

MATERIALS

Brass CZ121 (IA)


316 Stainless Steel (IAS)
Aluminium Alloy (IAA)

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

2006 Catalogue Page 7.1.3

Peppers Cable Glands Limited 2006

example part
number

Sample: IA/NP/M20/050NPT
IA
NP
M20
050NPT

- Body material (Brass)


- Nickel plating
- Male thread size
- Female thread size (12 NPT)

DIMENSIONAL INFORMATION FOR METRIC TO METRIC VERSIONS


Metric

Hex A/F

Hex A/C

Total Length

Male Length

Female Depth

Bore

M20

30.5

35.5

54.0

16.0

17.0

13.5

M25

37.6

43.2

54.0

16.0

17.0

19.0

M32

47.2

54.3

54.0

16.0

17.0

25.0

M40

55.9

64.1

54.0

16.0

17.0

30.0

M50

70.1

80.8

54.0

16.0

17.0

40.5

M63

80.0

92.0

54.0

16.0

17.0

53.0

M75

95.3

109.5

54.0

16.0

17.0

65.0

M80 x 2.0

100.0

114.0

63.0

20.0

22.0

70.0

M85 x 2.0

106.4

114.0

63.0

20.0

22.0

75.0

M90 x 2.0

106.4

114.0

63.0

20.0

22.0

80.0

All Dimensions are in Millimetres

NOTES:

Full installation instructions are supplied with insulated adaptors, the instructions must be read prior to installation and adhered to
in full

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

For Flameproof Exd applications the female thread into which the adaptor is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1)

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 7.1.3 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Accessories:- Stopping Plugs - Type SPMH


Part of our Accessories Range
2006 Catalogue Page 7.2.1
SPMH Series Dual Certified Metallic Dome Head Stopping Plugs provide a method of filling unused entries in Ex
equipment while maintaining Flameproof Exd and Increased Safety Exe methods of explosion protection and IP66, 68 for
IEC type applications. Class I, Division 2 and NEMA 4X, 6P for NEC/CEC type applications.

CERTIFication

CENELEC
SIRA00ATEX1094 I M2 II 2DG E Ex de IandIIC
SIRA00ATEX1094 II 2DG E Ex de IIC (Aluminium)
CSA / A Ex
Class I, Zone 1, Ex de IandIIC
Class I, Division 1and2 ABCD
Class II EFG, Class III
GOST R-Exde IICY
POCC GB 05.B00482
IECEx Ex d IIC / Ex e II / Ex d I
IECEx SIR 05.0042U

INGRESS
PROTECTION

IP66 68, CSA Enclosure Type (NEMA) 4X 6P

IMPACT RESISTANCE

20Nm (7Nm Aluminium)

OPERATING
TEMPERATURES

-50C to +85C

MATERIALS

Brass CZ121 (SPMH)


316 Stainless Steel (SPMHS)
Aluminium Alloy (SPMHA)

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

Seals

The standard O Ring material is Nitrile

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

example part
number

Sample: SPMH/NP/M20
SPMH - Stopping Plug type and body material (Brass)
NP - Nickel plating
M20 - Male thread size

2006 Catalogue Page 7.2.1

Peppers Cable Glands Limited 2006

SIZES AVAILABLE AND DIMENSIONAL REFERENCES


Metric

M16

Dim Ref

NPT

Dim Ref

ISO Pipe

Dim Ref

PG

Dim Ref

M20

12

M25

34

M32

13.5

M40

114

114

16

M50

112

112

21

M63

29

212

36

42

48

M75

212

M80 x 2.0

M85 x 2.0

312

M90 x 2.0

M100 x 2.0

12

34

11

DIMENSIONS

Dimension Reference

Head Diameter Minimum 6.0mm larger than the major thread diameter

Hex Socket A/F

6.0

8.0

10.0

10.0

10.0

10.0

10.0

Total Length

21.5

21.5

21.5

24.5

25.5

29.0

39.0

Thread Length

16.0

16.0

16.0

19.0

22.0

23.5

33.5

All Dimensions are in Millimetres

NOTES:

SPMH type stopping plugs are designed for use within either clearance holes or parallel threaded entries, for taper threaded entries
we would recommend the use of SPA type stopping plugs

Full installation instructions are supplied with stopping plugs, the instructions must be read prior to installation and adhered to in
full

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

For Flameproof Exd applications the female thread into which the stopping plug is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1)

For NEC/CEC Explosion Proof applications an engagement of at least 8 full threads must be achieved for parallel threads and 5 full
threads must be achieved for tapered threads

Where metallic stopping plugs are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth
circuit of the system

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 7.2.1 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Accessories:- Stopping Plugs - Type SPMHN


Part of our Accessories Range
2006 Catalogue Page 7.2.2
SPMHN Series Glass Filled Nylon Dome Head Stopping Plugs provide a method of filling unused entries in increased safety
equipment, maintaining Increased Safety Exe methods of explosion protection and IP66, 68 for IEC type applications.

CERTIFication

CENELEC
SIRA00ATEX3091 II 2DG E Exe II
CSA / A Ex
Class I, Zone 1, Ex e II
Class I, Division 2 ABCD
Class II EFG, Class III

INGRESS
PROTECTION

IP66 68, CSA Enclosure Type (NEMA) 4X 6P

IMPACT RESISTANCE

7Nm

OPERATING
TEMPERATURES

-50C to +85C

MATERIALS

30% Glass Filled Nylon (SPMHN)

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

Seals

The standard O Ring material is Nitrile

example part
number

Sample: SPMHN/M20
SPMHN - Stopping Plug type and body material (Nylon)
M20 - Male thread size

2006 Catalogue Page 7.2.2

Peppers Cable Glands Limited 2006

SIZES AVAILABLE AND DIMENSIONAL REFERENCES


Metric

Dim Ref

NPT

Dim Ref

PG

Dim Ref

M16

M20

12

M25

34

11

M32

13.5

M40

114

16

M50

112

21

M63

29

212

M75

36

42

48

DIMENSIONS

Dimension Reference

Head Diameter

Hex Socket A/F

6.0

Minimum 6.0mm larger than the major thread diameter


8.0

10.0

Total Length

21.5

21.5

21.5

Thread Length

16.0

16.0

16.0

All Dimensions are in Millimetres

NOTES:

SPMHN type stopping plugs are designed for use within either clearance holes or parallel threaded entries, for taper threaded
entries we would recommend the use of SPA type stopping plugs

Full installation instructions are supplied, the instructions must be read prior to installation and adhered to in full

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 7.2.2 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Accessories:- Stopping Plugs - Type SPA or SPB


Part of our Accessories Range
2006 Catalogue Page 7.2.3
SPA or SPB Series Certified Metallic Stopping Plugs provide a method of filling unused entries in Ex equipment,
maintaining Flameproof Exd method of explosion protection and IP54 for IEC type applications. Class I, Division 1 and
NEMA 3 for NEC/CEC type applications.
SPA Type - Externally accessible hexagon recess
SPB Type - Internally accessible hexagon recess
CERTIFication

CENELEC
SIRA99ATEX1113 II 2DG E Ex d IIC
CSA / A Ex
Class I, Zone 1, Ex d IIC
Class I, Division 1 & 2 ABCD
Class II EFG, Class III
IECEx Ex d IIC
IECEx SIR 05.0042U

INGRESS
PROTECTION

IP54, CSA Enclosure Type (NEMA) 3

IMPACT RESISTANCE

7Nm

OPERATING
TEMPERATURES

-50C to +85C

MATERIALS

Brass CZ121 (SPAB, SPBB)


316 Stainless Steel (SPAS, SPBS)
Aluminium Alloy (SPAA, SPBA)

THREADS

ISO Metric; ET; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

example part
number

Sample: SPAB/NP/M20
SPA - Stopping Plug type (Externally accessible hexagon recess)
B
- Body material (Brass)
NP - Nickel plating
M20 - Male thread size

2006 Catalogue Page 7.2.3

Peppers Cable Glands Limited 2006

SIZES AVAILABLE AND DIMENSIONAL REFERENCES


Metric

M16

Dim Ref

NPT

Dim Ref

ISO Pipe

Dim Ref

PG

Dim Ref

M20

12

M25

34

M32

13.5

M40

114

114

16

M50

112

112

21

M63

29

212

36

42

48

M75

212

M80 x 2.0

M85 x 2.0

312

M90 x 2.0

M100 x 2.0

12

34

11

DIMENSIONS

Dimension Reference

Hex Socket A/F

Length (min)

6.0

8.0

16.0

17.0

10.0

10.0

10.0

17.0

14.0

16.0

10.0

10.0

10.0

18.0

22.0

25.0

All Dimensions are in Millimetres

NOTES:

Full installation instructions are supplied with stopping plugs, the instructions must be read prior to installation and adhered to in
full

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

For Flameproof Exd applications the female thread into which the stopping plug is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1)

For NEC/CEC Explosion Proof applications an engagement of at least 8 full threads must be achieved for parallel threads and 5 full
threads must be achieved for tapered threads

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 7.2.3 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Accessories:- Breather Drain - Type ACDPE


Part of our Accessories Range
2006 Catalogue Page 7.3.1
ACDPE Series Breather Drain provides a method of effectively draining any moisture within an enclosure whilst allowing
the air inside the enclosure to breathe with the surrounding atmosphere. ACDPE series breather drains maintain
Increased Safety Exe method of explosion protection and IP66 for IEC type applications.

CERTIFication

CENELEC
SIRA99ATEX3050U I M2 II 2DG EExe I/II; II 2DG E
Exe (Glass Filled Nylon and Aluminium)
CSA / A Ex
Class I, Zone 1, Exe II; Class I Division 2, Groups
ABCD
GOST R-Exe IIU
POCC GB 05.B00482

APPLICATION

Internal Dust Seal provides ingress protection to IP66 and 4x, with the largest possible pore size to aid draining,
whilst retaining filtration capabilities that remove debris from the moisture and retains it on the surface where
it can easily be removed with compressed air. Additionally the structural strength and chemical resistance
characteristics of the material enable the filter to meet the requirements of hazardous area installations
Castellated Locknut allows moisture to pass between the locknut and the enclosure, draining via holes in the
thread without any build up of moisture in the bottom of the enclosure
Captive O Ring Seal is located within a recess on the face of the breather drain again optimising ingress
protection, ensuring the oring is not displaced during installation and helping protect the O ring from the
environmental damage
External Drainage via two ports optimises ingress protection without compromising the draining capabilities

INGRESS
PROTECTION

IP66, CSA Enclosure Type 4x, NEMA 4x

IMPACT RESISTANCE

20Nm. (7Nm GF Nylon and Aluminium)

OPERATING
TEMPERATURES

-50C to +85C

MATERIALS

Brass CZ121 (ACDPEB)


316 Stainless Steel (ACDPES)
Aluminium Alloy (ACDPEA)
30% Glass Filled Nylon (ACDPEBN)

VARIATIONS

Clearance hole (10): 10mm length of thread, supplied complete with a castellated locknut and having 2 holes in
the thread wall positioned directly opposite each other
Threaded Entry (15 or 15NL): 15mm length of thread, either supplied with (15) or without castellated locknut
(15NL) and having 3 holes in the thread wall, offset to provide a 9mm range to accommodate differing wall
thickness

THREADS

ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG

Seals

The standard O Ring material is Nitrile

plating

Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)

2006 Catalogue Page 7.3.1

Peppers Cable Glands Limited 2006

example part
number

Sample: ACDPEB/NP/M20/15
ACDPEB - Breather Drain type and material (Brass)
NP - Nickel plating
M20 - Male thread size
15 - Male thread length (15mm) and drain holes in thread (x 3 offset)

DIMENSIONAL DATA

Size

Hex A/F

Hex A/C

M20 - 12 NPT

28.6mm

32.9mm

M25 - 34NPT

34.9mm

40.2mm

Thread Length

Head Length

10 (2 Hole) or 15 (3 Hole)

15mm

All Dimensions are in Millimetres

NOTES:

30% glass filled nylon variations are only available with 15mm length of thread version and are supplied with or without a brass
castellated nut

Full installation instructions are supplied with the breather drain, the instructions must be read prior to installation and adhered to
in full

Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch

Where metallic breather drains are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth
circuit of the system

http://www.cableglands.com
Peppers Cable Glands Limited 2006

Page 7.3.1 2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Accessories:- General
Part of our Accessories Range
2006 Catalogue Page 7.4.1
A full range of accessories including locknuts, earthtags, sealing washers, serrated washers and shrouds for use with all
our cable glands

AVAILABILITY
ACCESSORY TYPE

GLAND TYPES/SIZE

THREAD TYPES

METRIC

NPT

BSP

PG

FRENCH

Locknuts provide a method of securing a threaded entry component into a piece of equipment
Brass (ACBLN)

All

M16 to M100

12 to 4

12 to 4

PG7 to PG48

F48

316 Stainless Steel

M16 to M100

12 to 4

12 to 4

PG7 to PG48

F48

Aluminium

M20 to M63

Nylon (ACNLN)

Nylon

M20 to M63

PG7 to PG48

Steel (ACMLN)

Industrial

M20 to M50

316 Stainless Steel (ACSLN)


Aluminium Alloy (ACALN)

Earth Tags provide an earth bond connection for an entry component


Brass (ACBET)
Aluminium Alloy (ACAET)

All

M16 to M100

12 to 4

12 to 4

PG7 to PG48

F48

Aluminium

M20 to M63

IP Sealing Washers are fitted between an entry component and the equipment to maintain the IP rating of the equipment
Nylon (ACNSW)

All

M16 to M100

12 to 4

12 to 4

PG7 to PG48

F48

Red Fibre (ACSFW)

All

M20 to M75

Serrated Star Washers can be used in conjunction with a locknut to provide additional fixing security and improve bonding
316 Stainless Steel (ACSSW)

All

M16 to M100

12 to 4

12 to 4

PG7 to PG48

F48

Galvanised Steel (ACGSW)

All

M20 to M75

Shrouds can be used to protect the gland from the surrounding environment
PVC (ACSPVC)

16 to 100

PCP (ACSPCP)

16 to 85

LSOH (ACSSIO)

16 to 85

Shrouds are not available for all glands, please see specific gland page for exact details

NOTES:

As standard ISO Metric threads are supplied with a 1.5mm pitch up to and including M75 and a 2.0mm pitch for sizes above M75

http://www.cableglands.com
2006 Catalogue Page 7.4.1

Peppers Cable Glands Limited 2006

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Entry Thread Reference Tables


Thread Types

ISO
METRIC
IEC 60423
1993

NPT
ANSI
B1.20.1
1983

NPS
ANSI
B1.20.1
1983

Thread Ref

Size

Major

TPI

Pitch

Thread Length

M16

16 x 1.5

15.97

16.93

1.50

16.0

Min Hex A/C


26.5

M20

20 x 1.5

19.97

16.93

1.50

16.0

33.0

M25

25 x 1.5

24.97

16.93

1.50

16.0

41.4

M32

32 x 1.5

31.97

16.93

1.50

16.0

50.6

M40

40 x 1.5

39.97

16.93

1.50

16.0

60.4

M50

50 x 1.5

49.97

16.93

1.50

16.0

71.5

M63

63 x 1.5

62.97

16.93

1.50

19.0

88.0

M75

75 x 1.5

74.97

16.93

1.50

19.0

99.0

M80

80 x 2.0

19.97

12.70

2.00

25.0

115.2

M85

85 x 2.0

84.97

12.70

2.00

25.0

115.2

M90

90 x 2.0

89.97

12.70

2.00

25.0

125.7

M100

100 x 2.0

99.97

12.70

2.00

25.0

125.7
26.5

050NPT

12

21.22

14.00

1.81

19.9

075NPT

34

26.57

14.00

1.81

20.1

33.0

100NPT

33.23

11.50

2.20

25.0

41.4

125NPT

114

41.99

11.50

2.20

25.6

50.6

150NPT

112

48.05

11.50

2.20

26.0

60.5

200NPT

60.09

11.50

2.20

26.9

71.5

250NPT

212

72.70

8.00

3.18

39.9

88.0

300NPT

88.61

8.00

3.18

41.5

99.0

350NPT

312

101.36

8.00

3.18

42.8

115.2

400NPT

113.97

8.00

3.18

44.0

125.7

050NPS

12

20.90

14.00

1.81

19.9

26.5

075NPS

34

26.26

14.00

1.81

20.1

33.0

100NPS

32.84

11.50

2.20

21.5

41.4

125NPS

114

41.61

11.50

2.20

25.6

50.6

150NPS

112

47.67

11.50

2.20

26.0

60.5

200NPS

59.72

11.50

2.20

26.9

71.5

250NPS

212

72.16

8.00

3.18

39.9

88.0

300NPS

88.06

8.00

3.18

41.5

99.0

350NPS

312

100.78

8.00

3.18

42.8

115.2

400NPS

113.43

8.00

3.18

44.0

125.7

PG7

PG7

12.50

20.00

1.27

16.0

26.5

PG9

PG9

15.20

18.00

1.41

16.0

26.5

PG

DIN 40430
1971

(W/D)

PG11

PG11

18.60

18.00

1.41

16.0

26.5

PG13.5

PG13.5

20.40

18.00

1.41

16.0

26.5

PG16

PG16

22.50

18.00

1.41

16.0

33.0

PG21

PG21

28.30

16.00

1.59

16.0

41.4

PG29

PG29

37.00

16.00

1.59

16.0

50.6

PG36

PG36

47.00

16.00

1.59

16.0

60.5

PG42

PG42

54.00

16.00

1.59

16.0

71.5

PG48

PG48

59.30

16.00

1.59

16.0

88.0

ISO Pipe
Parallel

F48

PG48 (FR)

59.61

11.00

2.31

26.9

71.5

050BSP

12

20.96

14.0

1.81

19.9

26.5

ISO R/7;

075BSP

34

26.44

14.0

1.81

20.1

33.0

100BSP

33.25

11.0

2.31

25.0

41.4

BS2779

125BSP

114

41.91

11.0

2.31

25.6

50.6

(BSPP, G,
R, PF)

150BSP

112

47.80

11.0

2.31

26.0

60.5

200BSP

5961

11.0

2.31

26.9

71.5

250BSP

212

75.18

11.0

2.31

39.9

88.0

050BST

12

20.96

14.0

1.81

19.9

26.5

ISO Pipe
Taper to

075BST

34

26.44

14.0

1.81

20.1

33.0

100BST

33.25

11.0

2.31

25.0

41.4

125BST

114

41.91

11.0

2.31

25.6

50.6

150BST

112

47.80

11.0

2.31

26.0

60.5

(BSPT, GK)

200BST

5961

11.0

2.31

26.9

71.5

250BST

212

75.18

11.0

2.31

39.9

88.0

ISO R/7;
BS21

Peppers Cable Glands Limited 2006

2006 Catalogue

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom
Telephone: +44 (0) 1276 64232
Facsimile: +44 (0) 1276 691752
Email: sales@peppers.co.uk

Ingress Protection
It is essential when selecting cable glands and/or accessories to ensure that the products will maintain the IP rating of the
equipment and the integrity of the installation.
IP Codes are based on the IEC Standard 529, degrees of protection provided by enclosures.
In most cases Peppers cable glands will maintain Ingress Protection of the equipment into which they are installed to:

IP 66

Dust tight. No ingress of dust possible

IP 67

Dust tight. No ingress of dust possible


Protected against harmful ingress of water when immersed between a depth of 150mm to 1m

IP 68

Dust tight. No ingress of dust possible


Protected against submersion. Suitable for continuous immersion in water at stated depth
(Depth stated for Peppers cable glands = 25m)

Protected against heavy seas or powerful jets of water. Prevents ingress sufficient to cause harm

DTS 01

This test was originally constructed by Shell and Esso in the UK to simulate the routine deluging of electrical equipment on
offshore installations

(Deluge)

The minimum requirements for Hazardous Location products is:

IP 54

Dust protected. Prevents ingress of dust sufficient to cause harm.


Protected from splashing water from any direction.

As a general guide to selecting the sealing method that is most likely to maintain the required IP rating for different entry
types, we recommend:
Clearance Holes - Integral O ring seal or nylon IP washer
Parallel Threaded Entries - Integral O ring seal, IP washer or non-hardening thread sealant
Taper Threaded Entries - Non-hardening thread sealant

Gland Weight Data


Gland Size

















16
20s
20
25
32
40
50s
50
63s
63
75s
75
80
85
90
100

Entry
Thread

Cable Gland Type


CR-1B

M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M80
M85
M90
M100

164
160
250
400
750
1095
1415
1295
2345
2006
1980
2200
3970
3300
4314
3537

E1WF
144
130
186
262
420
672
980
758
1410
1140
1745
1375
3255
2655
3559
2795

CWLE
134
124
180
262
402
680
1040
764
1410
1185
1730
1495
3130
2500
3280
3054

A2LF

A2LDSF

RG22E

142
144
158
256
298
556
980
796
1410
1170
1565
1310
2130
1980
2360
2285

6
-
8
16
28
35
-
65
-
74
-
-
-
-
-
-

84
90
94
152
176
332
570
458
850
684
954
764
1430
1290
1510
1485

CR-CB
165
165
240
400
725
1060
1435
1340
2100
2025
2330
2240
4985
4065
5215
4410

All weights are approximate and shown in grams


NOTES:

Weights shown are for Brass versions (except Nylon RG22E)


To estimate weights for 316 Stainless Steel versions apply a factor of 0.92
To estimate weights for Aluminium versions apply a factor of 0.32
Weights for glands with non-metric entry threads will vary
Approximate weights for A2LC*F, E8XF, A8F are available on application
Approximate weights for E1W, CWL and A2L industrial glands are the same as for Ex versions

2006 Catalogue

II

CR-XB
-
115
170
260
384
585
-
700
-
1040
-
1150
2730
2255
2790
2450

CR-UB
-
180
260
385
570
885
1035
1160
1555
1695
1750
1880
3860
3250
3985
3580

CR-SB
-
-
215
340
485
730
-
875
-
1355
-
1475
3415
2830
3985
3580

BW
52
84
140
180
436
480
910
1070
1770
-

HEALTH & SAFETY


When used and installed as prescribed within the data sheets provided, Peppers
Cable Glands products will not cause any danger or hazard to the health or
safety of persons, animals or property. The products should be installed by
suitably trained/skilled personnel and in full accordance with the relevant
legislative regulations (including the UKs IEE wiring regulations) and the
accepted rules for the industry concerned.

WARNING
Peppers cable glands should not be used within any application other than
those specified for each product, unless Peppers Cable Glands issue a statement
in writing that the product is suitable for the specified application. For further
information on each product, we refer you to the specific Assembly Instructions
and General Arrangement drawings, which are available on request. Using the
links on our web site catalogue pages and instructions may be downloaded from
the internet. Peppers Cable Glands take no responsibility for any damage, injury
or other consequential loss caused where the glands are not installed or used
according to our Assembly Instructions.

HAZARDOUS AREA INSTALLATION


When selecting equipment for use in the hazardous areas the appropriate
national or international standards or codes of practice must be considered.

GENERAL SUITABILITY FOR THE INSTALLATION ENVIRONMENT


Peppers cable glands are designed for normal industrial environments with
regard to temperature, humidity and vibration. Construction materials include
steel, brass and aluminium alloys, and neoprene, nitrile and silicone rubbers.
To minimise galvanic corrosion, the metallic gland components are made from
similar materials. Material compatibility under chemical corrosion or attack by
aggressive substances must be considered before installation.

SPARE PARTS
Apart from the accessories listed in this catalogue, Peppers does not supply spare
parts for any of its glands. Glands are designed so that no part from another
manufacturers gland will fit Peppers gland. If part of a gland needs to be
replaced for any reason, the user should ensure an entire new gland is fitted.

DIMENSIONAL DATA
The dimensions shown within this catalogue may vary due to material availability.

CE CONFORMITY
Copies of Peppers CE declarations regarding LVD, EMC and ATEX directives are
available upon request. BS EN 50262 classification with regard to mechanical and
electrical properties of cable glands is available upon request.

TERMS & CONDITIONS


Full terms and conditions of sale are available upon request.

Global Approvals

Universal Solutions

ATEX CENELEC IECEx GOST CSA UL NEPSI ISO9001:2000

Quality Products Accurate Advice Unbeatable Service


Peppers specialise in the manufacture of cable glands for use in hazardous locations found within Oil, Gas, Petrochemical
and Marine installations. Our products carry global certification and many feature our unique single orientation clamping
system CROCLOCK. "No reversible components no mistakes". The recently released barrier glands have won awards
for technical innovation and feature many user benefits. Peppers Cable Glands, we won't let you down.

Peppers Cable Glands Limited


Stanhope Road . Camberley . Surrey GU15 3BT . UK
Tel: +44 (0) 1276 64232
Fax: +44 (0) 1276 691752
Email: sales@peppers.co.uk

www.cableglands.com

http://www.cableglands.com

www.cableglands.com

Your local Agent or Distibutor

Peppers Cable Glands Limited


Stanhope Road, Camberley, Surrey, GU15 3BT, Great Britain
Tel: +44 (0) 1276 64232 Fax: +44 (0) 1276 691752 Email: sales@peppers.co.uk

You might also like