Professional Documents
Culture Documents
Product Catalogue
www.cableglands.com
Introduction to
Peppers
Peppers Cable Glands Limited specialise in the manufacture of
cable glands for use in the hazardous locations found within Oil,
Gas and Petrochemical installations.
At Peppers we have manufactured and marketed our own range
of cable glands for over 60 years and have an enviable reputation
for delivering quality products along with the highest possible
levels of customer service and flexibility.
With the help of our distribution network, we aim to provide the
global market with regular quantities of glands either from stock
or within a matter of days, and project quantities within just a
few weeks.
Typical users of Peppers products include Oil and Gas operators,
petrochemical and pharmaceutical companies, engineering
contractors and hazardous area equipment manufacturers worldwide.
Peppers is part of the Currie & Warner Group, one of Europes
leading turned part operations, again with a global customer
base.
To ensure consistent product quality Peppers work within a
Quality Assurance System that is approved to ISO 9001:2000.
Due to Peppers commitment to an on-going programme of
product development you may find products available which are
not yet described in our catalogues. Some may also be slightly
different from current descriptions. Any differences which effect
safety will result in the relevant catalogue page being re-issued.
The best place to check for up to date information is our website
http://www.cableglands.com
Outer Seal
Inner Seal
Lead Option
Armour Clamp
Certification
IP Rating
Page No.
ATEX / CSA / GOST / IECEx / NEPSI Approved Glands Featuring Elastomeric Seals
CR-1
Universal
Crocklock
1.1.0
E1WF
Deluge, IP66,68,
Exd/Exe
NEMA 4X
Exd/Exe
IP66,
67
(CSA Pending)
1.2.0
CWLE
Exe
(CSA Pending)
1.3.0
A2LF
A2LDSF
x2
A2LC*F-Conduit
RG22E
IP66, 67
Deluge, IP66,68,
Exd/Exe
NEMA 4X
Deluge, IP66,68,
Exd/Exe
NEMA 4X
Deluge, IP66,68,
Exd/Exe
NEMA 4X
Exe
IP66, 68
(ATEX Only)
2.1.0
2.2.0
2.3.0
2.4.0
ATEX / GOST / IECEx / NEPSI Approved Glands Featuring Elastomeric Seals For Flat Cable
E8XF
Flat Cable
Flat Cable
Exd/Exe
Braid
IP66
3.1.0
A8F
Flat Cable
Exd/Exe
IP68
3.2.0
CR-C
Compound
Universal
Crocklock
CR-X
Compound
Compound
CR-U
Compound
CR-S
(Stopper Box)
Compound
Deluge, IP66,68,
Exd
NEMA 4X
Deluge, IP66,68,
Exd
NEMA 4X
Deluge, IP66,68,
Exd
NEMA 4X
Exd
Deluge, IP66,68,
NEMA 4X
4.1.0
4.2.0
4.2.1
4.3.0
UL-C
Compound
UL-C
Compound
Compound
UL-C
Compound
Class I
Universal
Deluge, IP66,68,
Div 1 ABCD
Crocklock
NEMA 4X
Deluge, IP66,68,
Class I
NEMA 4X
Div 2 ABCD
Deluge, IP66,68,
Class I
NEMA 4X
Div 2 ABCD
4.4.0
4.5.0
4.5.1
BW
Industrial
(BS6121)
IP30
5.1.0
CWL
Industrial
IP66
5.2.0
E1W
Industrial
IP67
5.3.0
A2L
Industrial
IP66, 68
5.4.0
ACCESSORIES
AR
ARN
IA
SPMH
SPMHN
SPA/SPB
ACDPE
GENERAL
IP66,68,
Exd/Exe
NEMA 4X 6P
IP66,68,
Exe
NEMA 4X 6P
IP66,68,
Exd
NEMA 3
IP66,68,
Exd/Exe
NEMA 4X 6P
IP66,68,
Exe
NEMA 4X 6P
IP66,68,
Exd
NEMA 3
IP66,68,
Exe
NEMA 4X
7.1.1
7.1.2
7.1.3
7.2.1
7.2.2
7.2.3
7.3.1
7.4.1
REFERENCE DATA
Ingress Protection
II
II
CERTIFication
CERTIFicate
GLAND MARKING
EExd Equipment
CR-1B type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and
compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2
APPLICATION
NO
YES
YES
EExe Equipment
Gas Group II, Zones 1 and 2
Enclosure Volume
Any
Any
2 litres or less
YES
YES
YES
Other Equipment
Ignitable Dust, Zones 21 and 22
INGRESS
PROTECTION
MATERIALS
VARIATIONS
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
Seals
plating
OPERATING
TEMPERATURES
accessories
example part
number
B
- Body material (Brass)
R - Reduced bore outer seal
K1 - Supplied complete with accessories (PVC Shroud)
ZP - Zinc plating
20s - Gland size with regards to cable acceptance range
M20 - Entry thread
Gland
Size
Entry
Thread
Length
Entry Threads
Max
Max
Across Protrusion
Corners Length
Metric
16
NPT/BSP
[B]
[A]
Reduced (R)
Armour
Acceptance
Range
Max
Min
Max
6.7
10.3
0.15 - 1.25
Shroud
Size
M20
12
or 34
16
28.0
78.0
3.4
8.4
9.0
13.5
or
34
16
28.0
78.0
7.2
11.7
11.5
16.0
9.4
12.5
0.15 - 1.25
L24
or 34
16
33.0
78.0
9.4
14.0
15.5
21.1
12.0
17.6
0.15 - 1.25
EL30
L24
20s
M20
12
20
M20
12
25
M25
34
or 1
16
41.4
90.0
13.5
20.0
20.3
27.4
16.8
23.9
0.15 - 1.60
EL38
32
M32
1 or 114
16
50.6
105.0
19.5
26.3
26.7
34.0
23.2
30.5
0.15 - 2.00
EL46
16
60.5
113.0
23.0
32.2
33.0
40.6
28.6
36.2
0.20 - 2.00
EL55
16
71.5
125.0
28.1
38.2
39.4
46.7
34.8
42.4
0.30 - 2.50
EL65
114
112
40
M40
50s
M50
50
M50
16
71.5
125.0
33.1
44.1
45.7
53.2
41.1
48.5
0.30 - 2.50
EL65
63s
M63
2 or 212
19
88.0
125.0
39.2
50.1
52.1
59.5
47.5
54.8
0.30 - 2.50
EL80
19
88.0
125.0
46.7
56.0
58.4
65.8
53.8
61.2
0.30 - 2.50
EL80
19
99.0
131.0
52.1
62.0
64.8
72.2
60.2
68.0
0.30 - 2.50
EL90
or
112 or 2
63
M63
212
75s
M75
212 or 3
75
M75
19
99.0
131.0
58.0
68.0
71.1
78.0
66.5
73.4
0.30 - 2.50
EL90
80
M80 x 2
3 or 312
25
115.2
170.0
62.2
72.0
77.0
84.0
0.45 - 3.15
L104
312
80H
M80 x 2
3 or
25
115.2
170.0
62.2
72.0
79.6
90.0
0.45 - 3.15
L104
85
M85 x 2
3 or 312
25
115.2
170.0
69.0
78.0
79.6
90.0
75.0
85.4
0.45 - 3.15
L104
90
M90 x 2
312
or 4
25
125.7
170.0
74.0
84.0
88.0
96.0
0.45 - 3.15
L114
90H
M90 x 2
312 or 4
25
125.7
170.0
74.0
84.0
92.0
102.0
0.45 - 3.15
L114
M100 x 2
312
25
125.7
170.0
82.0
90.0
92.0
102.0
87.4
97.4
0.45 - 3.15
L114
100
or 4
Gland Size does not necessarily equate to the entry thread size
Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be
achieved for tapered threads
Where CR-1 type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth
circuit of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/
installation
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
When used to terminate unarmoured cable, the gland is suitable only for fixed installations. The cable must be clamped near the
gland to prevent pulling and twisting.
CERTIFication
CERTIFicate
GLAND MARKING
APPLICATION
Exd Equipment
E
E1WF type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and
compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2
Gas Group
IIC, IIB, IIA
IIB, IIA
IIB, IIA
EExe Equipment
Gas Group II, Zones 1 and 2
INGRESS
PROTECTION
MATERIALS
Enclosure Volume
Any
Any
2 litres or less
Which Zone
Zone 1 or 2
Zone 2
Zone 1
Other Equipment
Ignitable Dust, Zones 21 and 22
Inner & outer sheath seal material: Standard (E1) Neoprene, black. Option (E3) Silicone, white.
Reduced bore outer sheath seal (R) Silicone, red. (E1WFR).
VARIATIONS
options
For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (E2WF); 316 Stainless Steel (E2WSF).
Integral Earth version for HV applications:
Brass (E1WIEF); 316 Stainless Steel (E1WIESF)
Omission of outer seal:
Brass (D1WF); 316 Stainless Steel (D1WSF)
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
Seals
CLAMPS
plating
OPERATING
TEMPERATURES
accessories
Gland
Size
Entry Threads
[B]
Metric
16
Max
Max
Across Protrusion
Corners
Length
[A]
Armour Acceptance
Range
Max
Shroud
Size
Reduced (R)
Min
Max
XZ
10.0
0.90
0.15-0.35
L24
NPT/BSP
M20
12
or 34
16
26.5
58.0
4.0
8.4
8.4
13.5
or
34
16
26.5
58.0
8.0
11.7
11.5
16.0
9.4
12.5
0.90-1.25
0.15-0.35
L24
or 34
16
33.0
58.0
6.7
14.0
15.5
21.1
12.0
17.6
0.90-1.25
0.15-0.50
L30
20s
M20
12
20
M20
12
4.9
25
M25
34
or 1
16
41.4
58.0
13.0
20.0
20.3
27.4
16.8
23.9
1.25-1.60
0.15-0.50
L38
32
M32
1 or 114
16
50.6
65.0
19.0
26.3
26.7
34.0
23.2
30.5
1.60-2.00
0.15-0.55
L46
40
M40
50s
M50
50
63s
114 or
112
16
60.5
72.0
25.0
32.2
33.0
40.6
28.6
36.2
1.60-2.00
0.20-0.60
L55
112 or 2
16
71.5
73.0
31.5
38.2
39.4
46.7
34.8
42.4
2.00-2.50
0.20-0.60
L65
M50
16
71.5
73.0
36.5
44.1
45.7
53.2
41.1
48.5
2.00-2.50
0.30-0.80
L65
M63
2 or 212
19
88.0
76.0
42.5
50.1
52.1
59.5
47.5
54.8
2.50
0.30-0.80
L80
19
88.0
76.0
49.5
56.0
58.4
65.8
53.8
61.2
2.50
0.30-0.80
L80
19
99.0
82.0
54.5
62.0
64.8
72.2
60.2
68.0
2.50
0.30-1.00
L90
63
M63
212
75s
M75
212 or 3
75
M75
19
99.0
82.0
60.5
68.0
71.1
78.0
66.5
73.4
2.50
0.30-1.00
L90
80
M80 x 2
3 or 312
25
115.2
110.0
62.2
72.0
77.0
84.0
3.15
0.45-1.00
L104
80H
M80 x 2
3 or 312
25
115.2
110.0
62.2
72.0
79.6
90.0
3.15
0.45-1.00
L104
85
M85 x 2
3 or 312
25
115.2
110.0
69.0
78.0
79.6
90.0
75.0
85.4
3.15
0.45-1.00
L104
90
M90 x 2
312
or 4
25
125.7
110.0
74.0
84.0
88.0
96.0
3.15
0.45-1.00
L114
90H
M90 x 2
312 or 4
25
125.7
110.0
74.0
84.0
92.0
102.0
3.15
0.45-1.00
L114
M100 x 2
312
25
125.7
110.0
82.0
90.0
92.0
102.0
87.4
97.4
3.15
0.45-1.00
L114
100
or 4
Gland Size does not necessarily equate to the entry thread size
"XZ" refers to the wire diameter in a woven steel wire armoured cable or the tape thickness in a steel tape armoured cable
E3*F gland size 20, the silicone inner seal only seals to a minimum of 11.0mm and NOT 6.7mm
Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be
achieved for tapered threads
Where E1WF type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit
of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
Design Standard
CERTIFication
CERTIFicate
GLAND MARKING
APPLICATION
EExe Equipment
Other Equipment
Ignitable Dust, Zones 21 and 22
INGRESS
PROTECTION
IP66
MATERIALS
VARIATIONS
options
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
Seals
CLAMPS
plating
OPERATING
TEMPERATURES
accessories
example part
number
Gland
Size
Entry Threads
Entry
Max
Max
Thread Across Protrusion
Length Corners
Length
[B]
Metric
16
[A]
Armour Acceptance
Range
Max
Shroud
Size
Reduced (R)
Min
Max
XZ
10.3
0.90-1.25
0.15-0.35
L24
NPT/BSP
M20
12
or 34
16
26.5
54.0
8.4
9.0
13.5
or
34
16
26.5
54.0
11.7
11.5
16.0
9.4
12.5
0.90-1.25
0.15-0.35
L24
or 34
16
33.0
54.0
14.0
15.5
21.0
12.0
17.6
0.90-1.25
0.15-0.50
L30
20s
M20
12
20
M20
12
6.7
25
M25
34
or 1
16
41.4
54.0
20.0
20.3
27.4
16.8
23.9
1.25-1.60
0.15-0.50
L38
32
M32
1 or 114
16
50.6
60.0
26.3
26.7
34.0
23.2
30.5
1.60-2.00
0.15-0.55
L46
40
M40
50s
M50
50
63s
114
or
112
16
60.5
67.0
32.2
33.0
40.6
28.6
36.2
1.60-2.00
0.20-0.60
L55
112 or 2
16
71.5
67.0
38.2
39.4
46.7
34.8
42.4
2.00-2.50
0.20-0.60
L65
M50
16
71.5
67.0
44.1
45.7
53.2
41.1
48.5
2.00-2.50
0.30-0.80
L65
M63
2 or 212
19
88.0
69.0
50.1
52.1
59.5
47.5
54.8
2.50
0.30-0.80
L80
63
M63
212
19
88.0
69.0
56.0
58.4
65.8
53.8
61.2
2.50
0.30-0.80
L80
75s
M75
212 or 3
19
99.0
77.0
62.0
64.8
72.2
60.2
68.0
2.50
0.30-1.00
L90
75
M75
19
99.0
77.0
68.0
71.1
78.0
66.5
73.4
2.50
0.30-1.00
L90
80
M80 x 2
3 or 312
25
115.2
104.0
72.0
77.0
84.0
3.15
0.45-1.00
L104
80H
M80 x 2
3 or 312
25
115.2
104.0
72.0
79.6
90.0
3.15
0.45-1.00
L104
85
M85 x 2
3 or 312
25
115.2
104.0
78.0
79.6
90.0
75.0
85.4
3.15
0.45-1.00
L104
90
M90 x 2
312 or 4
25
125.7
104.0
84.0
88.0
96.0
3.15
0.45-1.00
L114
90H
M90 x 2
312
or 4
25
125.7
104.0
84.0
92.0
102.0
3.15
0.45-1.00
L114
100
M100 x 2
312 or 4
25
125.7
104.0
90.0
92.0
102.0
87.4
97.4
3.15
0.45-1.00
L114
Gland Size does not necessarily equate to the entry thread size
"XZ" refers to the wire diameter in a woven steel wire armoured cable or the tape thickness in a steel tape armoured cable
Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
Where CWLE type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit
of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Design Standard
CERTIFication
CERTIFicate
GLAND MARKING
APPLICATION
Exd Equipment
E
A2LF type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and
compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2
INGRESS
PROTECTION
Enclosure Volume
2 litres or less
Any
2 litres or less
Which Zone
Zone 1 or 2
Zone 2
Zone 1
EExe Equipment
Gas Group II, Zones 1 and 2
Other Equipment
Ignitable Dust, Zones 21 and 22
MATERIALS
VARIATIONS
options
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
Seals
plating
OPERATING
TEMPERATURES
accessories
example part
number
Gland Size
Entry Threads
Metric
Entry Thread
Length
Max Across
Corners
[B]
[A]
Max
Protrusion
Length
Shroud Size
Min
Max
NPT/BSP
16
M20
12
or 34
16
28.0
33.0
4.0
8.4
L24
20s
M20
12
or 34
16
28.0
33.0
7.2
11.7
L24
34
20
M20
12
16
33.0
33.0
9.6
14.0
L30
25
M25
34 or 1
16
41.4
33.0
13.5
20.0
L38
M32
114
16
50.6
33.0
19.5
26.3
L46
16
60.5
37.0
23.0
32.2
L55
16
71.5
37.0
28.2
38.2
L65
32
or
1 or
40
M40
50s
M50
50
M50
16
71.5
37.0
33.2
44.1
L65
63s
M63
2 or 212
19
88.0
37.0
39.3
50.1
L80
63
M63
212
19
88.0
37.0
46.7
56.0
L80
75s
M75
212 or 3
19
99.0
37.0
52.3
62.0
L90
75
M75
19
99.0
37.0
58.1
68.0
L90
80
M80 x 2
3 or 312
25
115.2
50.0
62.3
72.0
L104
85
M85 x 2
3 or 312
25
115.2
50.0
69.1
78.0
L104
90
M90 x 2
312 or 4
25
125.7
50.0
74.1
84.0
L114
M100 x 2
312
25
125.7
50.0
82.0
90.0
L114
100
114 or
112
112 or 2
or 4
Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting
Gland Size does not necessarily equate to the entry thread size
Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be
achieved for tapered threads
Where A2LF type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit
of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/
installation
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Design Standard
CERTIFication
CERTIFicate
GLAND MARKING
APPLICATION
Exd Equipment
E
A2LDSF type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and
compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2
Gas Group Internal Ignition Source
IIC, IIB, IIA
NO
IIB, IIA
YES
IIB, IIA
YES
Enclosure Volume
Any
Any
2 litres or less
EExe Equipment
Gas Group II, Zones 1 and 2
Other Equipment
Ignitable Dust, Zones 21 and 22
INGRESS
PROTECTION
MATERIALS
Which Zone
Zone 1 or 2
Zone 2
Zone 1
options
For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (A4LDSF); 316 Stainless Steel (A4LDSSF)
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
Seals
plating
OPERATING
TEMPERATURES
accessories
example part
number
Gland Size
- Zinc plating
- Gland size with regards to cable acceptance range
- Entry thread
Entry Threads
Entry Thread
Length
Max Across
Corners
Max Protrusion
Length
Shroud Size
Metric
[B]
[A]
Min
Max
NPT/BSP
16
M20
12
or 34
16
28.0
66.0
4.0
8.4
L24
20s
M20
12
or 34
16
28.0
66.0
7.2
11.7
L24
12
34
20
M20
25
M25
34
32
M32
1 or 114
16
45.1
66.0
19.5
26.3
L41
40
M40
114 or 112
16
55.9
74.0
23.0
32.2
L51
50s
M50
112 or 2
16
71.5
74.0
28.2
38.2
L65
50
M50
16
71.5
74.0
33.2
44.1
L65
19
88.0
74.0
39.3
50.1
L80
19
88.0
74.0
46.7
56.0
L80
19
99.0
74.0
52.3
62.0
L90
63s
M63
63
M63
2 or
or 1
212
212
212
16
29.7
66.0
9.6
14.0
L27
16
39.6
66.0
13.5
20.0
L36
75s
75
M75
19
99.0
74.0
58.1
68.0
L90
80
M80 x 2
3 or 312
25
115.2
100.0
62.3
72.0
L104
85
M85 x 2
3 or 312
25
115.2
100.0
69.1
78.0
L104
90
M90 x 2
312 or 4
25
125.7
100.0
74.1
84.0
L114
M100 x 2
312
25
125.7
100.0
82.0
90.0
L114
100
M75
or
or 3
or 4
Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting
Gland Size does not necessarily equate to the entry thread size
Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be
achieved for tapered threads
Where A2LF type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit
of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/
installation
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
http://www.cableglands.com
Peppers Cable Glands Limited 2006
CERTIFication
CERTIFicate
GLAND MARKING
APPLICATION
Exd Equipment
E
A2L**F type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and
compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2
Gas Group
IIC, IIB, IIA
IIB, IIA
IIB, IIA
Enclosure Volume
Any
Any
2 litres or less
EExe Equipment
Gas Group II, Zones 1 and 2
INGRESS
PROTECTION
MATERIALS
Which Zone
Zone 1 or 2
Zone 2
Zone 1
Other Equipment
Ignitable Dust, Zones 21 and 22
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
Seals
plating
OPERATING
TEMPERATURES
accessories
example part
number
Gland Size
Entry Threads
Metric
Entry Thread
Length
Max Across
Corners
[B]
[A]
Conduit Connector
Min
Max
NPT/BSP
NPT
ISO
16
M20
12
or 34
16
28.0
4.0
8.4
12
or 34
M20
20s
M20
12
or 34
16
28.0
7.2
11.7
12
or 34
M20
12
34
12
34
20
M20
16
33.0
9.6
14.0
25
M25
34
or 1
16
41.4
13.5
20.0
34
or 1
M25
32
M32
1 or 114
16
50.6
19.5
26.3
1 or 114
M32
40
M40
114 or 112
16
60.5
23.0
32.2
114 or 112
M40
50s
M50
50
M50
or
112
or 2
2
2 or
212
16
71.5
28.2
38.2
16
71.5
33.2
44.1
or
112
or 2
2
212
M20
M50
M50
63s
M63
19
88.0
39.3
50.1
63
M63
212
19
88.0
46.7
56.0
212
M63
75s
M75
212 or 3
19
99.0
52.3
62.0
212 or 3
M75
75
M75
19
99.0
58.1
68.0
M75
2 or
M63
Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting
Gland Size does not necessarily equate to the entry thread size
Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be
achieved for tapered threads
Where A2LF type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit
of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/
installation
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
Other conduit connection threads eg PG, BSP are available upon request
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Design Standard
CERTIFication
CERTIFicate
GLAND MARKING
Example:
SIRA 00ATEX1072X EB (Cable Range)
EExeII
II2GD
Exe Equipment
Gas Group II, Zones 1 and 2
INGRESS
PROTECTION
MATERIALS
THREADS
ISO Metric; PG
OPERATING
TEMPERATURES
accessories
example part
number
Sample: RG22E/M20
RG22E:
RG22E - Gland type, certification (Exe) and body colour, black (RG22UE, Blue)
Gland Size
Metric
Entry
Thread
Length
Max
Across
Corners
PG
Min
Max
6.0
16.5
3.5
M16
20.9
5.0
8.0
11
24.2
6.0
10.0
M20
13.5
10
26.4
8.0
13.5
16
10
28.6
10.0
15.0
M25
21
11
35.2
13.0
19.0
M32
29
12
45.1
18.0
25.0
M40
36
14
57.2
24.0
32.0
M50
42
16
64.9
29.0
38.0
M63
48
16
71.5
36.0
44.0
NOTES:
Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting
Gland sizes M25 and above shall not be used for applications where there is a "high" risk of mechanical damage
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Design Standard
CERTIFication
CERTIFicate
GLAND MARKING
APPLICATION
Exd Equipment
E
E8XF type glands will only maintain Flameproof Exd integrity when used with cable that has a suitable profile and is
compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2
Gas Group
IIC, IIB, IIA
IIB, IIA
IIB, IIA
EExe Equipment
Gas Group II, Zones 1 and 2
INGRESS
PROTECTION
Enclosure Volume
2 litres or less
Any
2 litres or less
Which Zone
Zone 1 or 2
Zone 2
Zone 1
Other Equipment
Ignitable Dust, Zones 21 and 22
IP66
MATERIALS
options
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
plating
OPERATING
TEMPERATURES
-60C to +180C
accessories
example part
number
Gland
Size
Entry Threads
Metric
Entry
Thread
Length
[B]
Max Across
Corners
Max
Protrusion
Length
[A]
Min Max
Max
Thickness
Min
Armour
Acceptance
Range
Max
X
20s
M20
16
26.5
58.0
6.3
11.7
4.0
7.0
7.9
11.7
4.5
7.0
0.1-0.30
20R
M20
16
33.0
58.0
8.1
13.5
5.8
6.2
7.5
16.1
3.0
8.3
0.1-0.45
20
M20
16
33.0
58.0
10.3
13.5
5.6
9.0
11.0
13.5
4.5
9.0
0.1-0.30
NOTES:
Gland Size does not necessarily equate to the entry thread size
Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be
achieved for tapered threads
Where E8XF type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit
of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Design Standard
CERTIFication
IECEx Ex d IIC / Ex e II
NEPSI Exd IIC / Exe II
A
CERTIFicate
GLAND MARKING
APPLICATION
Exd Equipment
E
A8F type glands will only maintain Flameproof Exd integrity when used with cable that has a suitable profile and is
compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2
Gas Group
IIC, IIB, IIA
IIB, IIA
IIB, IIA
Enclosure Volume
Any
Any
2 litres or less
Which Zone
Zone 1 or 2
Zone 2
Zone 1
EExe Equipment
Other Equipment
INGRESS
PROTECTION
IP68 @ 25 metres
MATERIALS
options
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
plating
OPERATING
TEMPERATURES
-60C to +180C
accessories
example part
number
Gland
Size
Entry
Thread
Length
Max
Across
Corners
Metric
[B]
[A]
20s
M20
16
20R
M20
16
M20
16
20
Entry Threads
Thickness
Min
Max
Min
Max
26.5
6.3
11.7
4.0
7.0
33.0
8.1
13.5
5.8
6.2
33.0
10.3
13.5
5.6
9.0
NOTES:
Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting
Gland Size does not necessarily equate to the entry thread size
Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be
achieved for tapered threads
Where A8F type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit
of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Croclock CR-C type glands provide a Flameproof EExd compound filled barrier, a seal on the outer sheath, a universal
armour clamp for armoured, screened or braided cable and an entry thread seal. The armour clamp provides an
electrical bond between the cable armour, screen or braid and the gland. Croclock CR-C type glands maintain EExd
Flameproof method of explosion protection; IP66, 68 to 100 metres and is deluge resistant.
Design Standard
CERTIFication
CERTIFicate
GLAND MARKING
Example:
SIRA 03ATEX1479X
I M2 II 2GD EExd I & IIC IP68 PEPPERS UK / XX / CR-CB - 20S (XX = Year Code)
Exd Equipment
E
CR-C type glands will maintain Flameproof Exd integrity when used with any armoured or unarmoured cable types.
Ref: IEC60079-14:2002 Section 10.4.2
APPLICATION
Gas Group
Enclosure Volume
Which Zone
YES
Any
Zone 1 or 2
YES
Other Equipment
Mining Equipment Group I, M2
Ignitable Dust, Zones 21 and 22
INGRESS
PROTECTION
CURING TIME
@ 21C
Conductor termination can be effected after 1 hour
The equipment can be energised after 4 hours
The compound chamber can be inspected after 4 hours
VARIATIONS
For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (CR-C2B); Stainless Steel (CR-C2S)
MATERIALS
options
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)
plating
OPERATING
TEMPERATURES
- 60C to +85C
accessories
example part
number
Gland
Size
Entry Threads
Metric
Entry
Thread
Length
Max
Across
Corners
[B]
[A]
Max
Protrusion
Length
NPT/BSP
Max
Over
Cores
Max
Inner
Sheath
Reduced (R)
Max
Min
Max
Armour
Acceptance
Range
Shroud
Size
16
M20
12
or 34
16
28.0
72.0
9.0
11.7
9.0
13.5
6.7
10.3
0.15 - 1.25
L24
20s
M20
12
or 34
16
28.0
72.0
10.4
11.7
11.5
16.0
9.4
12.5
0.15 - 1.25
L24
20
M20
12
34
16
33.0
73.0
14
12.5
14.0
15.5
21.1
12.0
17.6
0.15 - 1.25
EL30
25
M25
16
41.4
83.0
25
17.8
20.0
20.3
27.4
16.8
23.9
0.15 - 1.60
EL38
32
M32
16
50.6
103.0
50
23.5
26.3
26.7
34.0
23.2
30.5
0.15 - 2.00
EL46
40
M40
114 or 112
16
60.5
105.0
80
28.8
32.2
33.0
40.6
28.6
36.2
0.20 - 2.00
EL55
50s
M50
16
71.5
115.0
100
34.2
38.2
39.4
46.7
34.8
42.4
0.20 - 2.50
EL65
50
M50
16
71.5
115.0
100
39.4
44.1
45.7
53.2
41.1
48.5
0.20 - 2.50
EL65
63s
M63
212
19
88.0
115.0
120
44.8
50.1
52.1
59.5
47.5
54.8
0.30 - 2.50
EL80
63
M63
212
19
88.0
115.0
120
50.0
56.0
58.4
65.8
53.8
61.2
0.30 - 2.50
EL80
75s
M75
19
99.0
122.0
140
55.4
62.0
64.8
72.2
60.2
68.0
0.30 - 2.50
EL90
75
M75
19
99.0
122.0
140
60.8
68.0
71.1
78.0
66.5
73.4
0.30 - 2.50
EL90
80
M80x2
3 or
312
25
115.2
162.0
160
64.4
72.0
77.0
84.0
0.45 - 3.15
L104
85
M85x2
3 or 312
25
115.2
162.0
180
69.8
78.0
79.6
90.0
75.0
85.4
0.45 - 3.15
L104
90
M90x2
312
or 4
25
125.7
166.0
200
75.1
84.0
88.0
96.0
0.45 - 3.15
L114
100
M100x2
312 or 4
25
125.7
166.0
220
80.5
90.0
92.0
102.0
87.4
97.4
0.45 - 3.15
L114
or
34
1 or
or 1
114
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of
EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and
should be achieved for tapered threads
If CR-C type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Croclock CR-X type glands provide a Flameproof EExd compound filled barrier and an entry thread seal. Croclock CR-X
type glands maintain EExd Flameproof method of explosion protection; IP66, 68 to 100 metres and is deluge resistant.
Design Standard
CERTIFication
CERTIFicate
GLAND MARKING
Example:
SIRA 03ATEX1479X
I M2 II 2GD EExd I & IIC IP68 PEPPERS UK / XX / CR-XB - 20S (XX = Year Code)
Exd Equipment
E
CR-X type glands will maintain Flameproof Exd integrity when used with any unarmoured cable types.
APPLICATION
Enclosure Volume
Which Zone
YES
Any
Zone 1 or 2
YES
Other Equipment
Mining Equipment Group I, M2
Ignitable Dust, Zones 21 and 22
INGRESS
PROTECTION
CURING TIME
@ 21C
Conductor termination can be effected after 1 hour
The equipment can be energised after 4 hours
The compound chamber can be inspected after 4 hours
MATERIALS
VARIATIONS
options
For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (CR-X2B); 316 Stainless Steel (CR-X2S)
THREADS
plating
OPERATING
TEMPERATURES
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)
Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)
-60C to +85C
accessories
example part
number
NP
- Nickel plating
Entry Threads
Metric
Entry Thread
Length
Max Across
Corners
[B]
[A]
Max
Protrusion
Length
NPT/BSP
Shroud Size
Max
No. of
Cores
Max
Over
Cores [C]
Max
Sheath
Diameter [D]
20s
M20
12
or 34
16
28.0
42.0
10.4
11.7
L24
20
M20
12
or 34
16
33.0
44.0
14
12.5
14.0
L30
25
M25
or 1
16
41.4
48.0
25
17.8
20.0
L38
32
M32
1 or 114
16
50.6
53.0
50
23.5
26.3
L46
40
M40
114 or 112
16
60.5
54.0
80
28.8
32.2
L55
50
M50
16
71.5
54.0
100
39.4
44.1
L65
63
M63
212
19
88.0
55.0
120
50.0
56.0
L80
75
M75
19
99.0
60.0
140
60.8
68.0
L90
80
M80x2
3 or
312
25
115.2
80.0
160
64.4
72.0
L104
85
M85x2
3 or 312
25
115.2
80.0
180
69.8
78.0
L104
90
M90x2
312
or 4
25
125.7
85.0
200
75.1
84.0
L114
100
M100x2
312 or 4
25
125.7
85.0
220
80.5
90.0
L114
34
NOTES:
Gland Size does not necessarily equate to the entry thread size
Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
Please note that dimensions (A) & (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of
EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should
be achieved for tapered threads
If CR-X type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Croclock CR-U type glands provide a Flameproof EExd compound filled barrier, a secondary weather seal on the outer
sheath and an entry thread seal. Croclock CR-U type glands maintain EExd Flameproof method of explosion protection;
IP66, 68 to 100 metres and is deluge resistant.
Design Standard
CERTIFication
CERTIFicate
GLAND MARKING
I M2 II 2GD EExd I & IIC IP68 PEPPERS UK / XX / CR-UB - 20S (XX = Year Code)
Exd Equipment
E
CR-U type glands will maintain Flameproof Exd integrity when used with any unarmoured cable types.
Ref: IEC60079-14:2002 Section 10.4.2
APPLICATION
Gas Group
Enclosure Volume
Which Zone
YES
Any
Zone 1 or 2
YES
Other Equipment
Mining Equipment Group I, M2
Ignitable Dust, Zones 21 and 22
INGRESS
PROTECTION
CURING TIME
@ 21C
MATERIALS
VARIATIONS
options
For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (CR-U2B); 316 Stainless Steel (CR-U2S)
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)
plating
OPERATING
TEMPERATURES
-60C to +85C
accessories
example part
number
NP
- Nickel plating
Entry Threads
Metric
16
Entry
Thread
Length
Max
Across
Corners
[B]
[A]
Max
Protrusion
Length
NPT/BSP
Cable Inner
Sheath / Cores [C]
Cable Outer
Sheath [D]
Max
No. of
Cores
Max
Over
Cores
Max
Inner
Sheath
8.4
8.4
Min
Max
3.4
8.4
Shroud
Size
M20
12
or 34
16
28.0
73.0
20s
M20
12
or
34
16
28.0
73.0
10.4
11.7
4.8
11.7
L24
20
M20
12
or 34
16
33.0
73.0
14
12.5
14.0
9.5
14.0
EL30
25
M25
34
or 1
16
41.4
74.0
25
17.8
20.0
11.7
20.0
EL38
32
M32
1 or 114
16
50.6
80.0
50
23.5
26.3
18.1
26.3
EL46
40
M40
114 or 112
16
60.5
87.0
80
28.8
32.2
22.6
32.2
EL55
50s
M50
16
71.5
87.0
100
34.2
38.2
28.2
38.2
EL65
50
M50
16
71.5
87.0
100
39.4
44.1
33.1
44.1
EL65
63s
M63
212
19
88.0
88.0
120
44.8
50.1
39.3
50.1
EL80
63
M63
212
19
88.0
88.0
120
50.0
56.0
46.7
56.0
EL80
75s
M75
19
99.0
97.0
140
55.4
62.0
52.3
62.0
EL90
75
M75
19
99.0
97.0
140
60.8
68.0
58.0
68.0
EL90
80
M80 x 2
3 or 312
25
115.2
123.0
160
64.4
72.0
61.9
72.0
L104
85
M85 x 2
3 or
312
25
115.2
123.0
180
69.8
78.0
69.1
78.0
L104
90
M90 x 2
312 or 4
25
125.7
123.0
200
75.1
84.0
74.1
84.0
L114
100
M100 x 2
312 or 4
25
125.7
123.0
220
80.5
90.0
81.8
90.0
L114
L24
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of
EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should
be achieved for tapered threads
If CR-U type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Croclock CR-S type glands provide Flameproof EExd compound filled barrier seal on the cables individual conductors
within a conduit. It also provides an entry thread seal. Croclock CR-S type glands maintain EExd Flameproof method of
explosion protection; IP66, 68 to 100 metres and is deluge resistant.
Design Standard
CERTIFication
CERTIFicate
GLAND MARKING
I M2 II 2GD EExd I & IIC IP68 PEPPERS UK/XX/CR-SB - 20 M20 M20 (XX = Year Code)
Exd Equipment
E
CR-S type glands will maintain Flameproof Exd integrity.
Ref: IEC60079-14:2002 Section 10.4.2
APPLICATION
Gas Group
Enclosure Volume
Which Zone
YES
Any
Zone 1 or 2
YES
Other Equipment
Mining Equipment Group I, M2
Ignitable Dust, Zones 21 and 22
INGRESS
PROTECTION
CURING TIME
@ 21C
MATERIALS
options
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel)
plating
OPERATING
TEMPERATURES
-60OC to +85OC
accessories
example part
number
- Fitting size = 20
NP
- Nickel plating
Metric
NPT
Metric
NPT
Entry
Thread
Length
Max
Across
Corners
[B]
[A]
16
33.0
Sealing Range
Cable Conductors / Cores
Max
Protrusion
Length
Max
No. of
Cores
Max
Over
Cores [C]
14
12.5
Max Cable
Inside Fitting
[D]
20
25
M25
34
or 1
M25
34
or 1
16
41.4
63.0
25
17.8
20.0
32
M32
1 or 114
M32
1 or 114
16
50.6
67.0
50
23.5
26.3
40
M40
114 or 112
M40
114 or 112
16
60.5
68.0
80
28.8
32.2
50
M50
M50
16
71.5
68.0
100
39.4
44.1
63
M63
212
M63
212
19
88.0
72.0
120
50.0
56.0
75
M75
M75
19
99.0
78.0
140
60.8
68.0
80
M80 x 2
3 or 312
M80 x 2
3 or 312
25
115.2
103.0
160
64.4
72.0
85
M85 x 2
3 or 312
M85 x 2
3 or 312
25
115.2
103.0
180
69.8
78.0
90
M90 x 2
312 or 4
M90 x 2
312 or 4
25
125.7
104.0
200
75.1
84.0
100
M100 x 2
312 or 4
M100 x 2
312 or 4
25
125.7
104.0
220
80.5
90.0
M20
12
or 34
M20
12
or 34
57.0
14.0
Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of
EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should
be achieved for tapered threads
If CR-S type glands are fitted into non-metallic enclosures they must be included within the earth circuit of the system
The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/installation
To maintain ingress protection a thread sealant should be applied to the conduit thread
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Design Standard
CERTIFication
CLASS I, DIVISION 1
CERTIFicate
GLAND MARKING
Example:
UL-CBR 20 1/2 NPT
PEPPERS GU15 3BT UK
CL I DIV 1 ABCD
-25+85C 4X
LISTED APPLICATION
INGRESS
PROTECTION
CURING TIME
@21C
Conductor termination can be effected after 1 hour
The equipment can be energised after 4 hours
MATERIALS
options
THREADS
plating
Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN) - All entry threads are nickel plated as standard
OPERATING
TEMPERATURES
-25C to +85C
accessories
example part
number
Gland
Size
Entry Threads
Entry
Thread
Length
[B]
Metric
NPT
Max
Max
Across Protrusion
Corners
Length
[A]
Max
Inner
Sheath
NPT
Armour Acceptance
Range
Cable Inner
Sheath [C]
Standard
Min
Max
Shroud
Size
Reduced (R)
Min
Max
16
M20
12
or 34
0.783
1.102
2.835 0.461
0.362
0.531
0.264
0.406 0.006-0.049
L24
20s
M20
12
or 34
0.783
1.102
2.835 0.461
0.453
0.630
0.370
0.492
0.006-0.049
L24
12
34
20
M20
25
M25
or
34
1 or
or 1
114
0.783
1.299
2.874 0.551
0.610
0.831
0.563
0.693
0.006-0.049
EL30
0.795
1.630
3.268 0.787
0.799
1.079
0.689
0.941
0.006-0.063
EL38
32
M32
40
M40
50s
M50
1.059
2.815
4.528 1.504
50
M50
1.059
2.815
4.528 1.736
1.571
4.528 1.972
1.571
4.528 2.205
114 or 112
0.985
1.992
4.055 1.035
1.051
1.339
0.984
1.201
0.006-0.079
EL46
1.008
2.382
4.134 1.268
1.299
1.598
1.154
1.425
0.008-0.079
EL55
1.551
1.839
1.499
1.669
0.008-0.098
EL65
1.799
2.094
1.618
1.909 0.008-0.098
EL65
2.051
2.343
1.846
2.157
0.012-0.098
EL80
2.299
2.591
2.118
2.409
0.012-0.098
EL80
63s
M63
212
63
M63
212
75s
M75
1.634
4.803 2.441
2.551
2.843
2.469
2.677
0.012-0.098
EL104
75
M75
1.634
4.803 2.677
2.799
3.071
2.618
2.890
0.012-0.098
EL104
Gland Size does not necessarily equate to the entry thread size
Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
Please note that dimensions (A) and (B) may differ for glands with parallel entry threads. Please refer to our thread data tables for
specific dimensions
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
For Class I Group A locations, the joint made by fitting the gland to the enclosure female thread must comply with standard UL 886
clause 6.1 as follows:-
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Type UL-X
Part of our UL Range
2006 Catalogue Page 4.5.0
UL-X Type Explosion-proof glands provide a compound seal preventing the passage of gas or vapours through the gland
and the propagation of flame into the cable core. The glands are UL listed; suitable for Marine Shipboard non-armoured
cable; NEMA 4X applications and are Deluge-Proof.
Design Standard
CERTIFication
GLAND MARKING
Example:
UL-XB 20 1/2 NPT
PEPPERS GU15 3BT UK
CL I DIV 1 ABCD
-25+85C 4X
LISTED APPLICATION
INGRESS
PROTECTION
CURING TIME
@21C
Conductor termination can be effected after 1 hour
The equipment can be energised after 4 hours
MATERIALS
options
THREADS
plating
Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN) - All entry threads are nickel plated as standard
OPERATING
TEMPERATURES
-25C to +85C
accessories
example part
number
Gland
Size
Trade Size
Gland type
Material (Brass)
Fitting size = 20
NPT entry thread
Entry
Thread
Length
[B]
Metric
NPT
Max
Max
Across Protrusion
Corners
Length
Maximum Sheath
Diameter [C]
Shroud
Size
[A]
NPT
20s
M20
12
or 34
0.783
1.102
1.654
0.461
L24
20
M20
12
or 34
0.783
1.299
1.732
0.551
L30
25
M25
34
or 1
0.795
1.630
1.890
0.787
L38
32
M32
1 or 114
0.985
1.992
2.087
1.035
L46
114
112
40
M40
50
M50
63
M63
212
1.571
75
M75
1.634
or
1.008
2.382
2.126
1.268
L55
1.059
2.815
2.126
1.736
L65
3.465
2.165
4.134
2.362
2.205
L80
2.677
L90
NOTES:
Gland Size does not necessarily equate to the entry thread size
Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
Please note that dimensions (A) and (B) may differ for glands with parallel entry threads. Please refer to our thread data tables for
specific dimensions
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
For Class I Group A locations, the joint made by fitting the gland to the enclosure female thread must comply with standard UL 886
clause 6.4.1 as follows:-
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Type UL-U
Part of our UL Range
2006 Catalogue Page 4.5.1
UL-U Type Explosion-proof glands featuring provide a compound seal preventing the passage of gas or vapours through
the gland and the propagation of flame into the cable core. The glands are UL listed; suitable for Marine Shipboard
non-armoured cable; NEMA 4X applications and are Deluge-Proof.
Design Standard
CERTIFication
CLASS I, DIVISION 2
GAS GROUPS ABCD
CERTIFicate
GLAND MARKING
Example:
UL-UB 20 1/2 NPT
PEPPERS GU15 3BT UK
CL I DIV 1 ABCD
-25+85C 4X
LISTED APPLICATION
INGRESS
PROTECTION
CURING TIME
@21C
Conductor termination can be effected after 1 hour
The equipment can be energised after 4 hours
MATERIALS
options
THREADS
plating
Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN) - All entry threads are nickel plated as standard
OPERATING
TEMPERATURES
-25C to +85C
accessories
example part
number
Gland
Size
Entry Threads
Gland type
Material (Brass)
Fitting size = 20
NPT entry thread
Entry
Thread
Length
[B]
Metric
NPT
Max
Max
Across Protrusion
Corners
Length
[A]
NPT
Shroud
Size
Max
Inner
Sheath
Min
Max
16
M20
12
or 34
0.783
1.102
2.835
0.461
0.134
0.331
L24
20s
M20
12
or 34
0.783
1.102
2.835
0.461
0.189
0.461
L24
12
34
20
M20
25
M25
34
32
M32
1 or 114
0.985
1.992
4.055
1.035
0.713
1.035
EL46
40
M40
114 or 112
1.008
2.382
4.134
1.268
0.890
1.268
EL55
50s
M50
1.059
2.815
4.528
1.504
1.110
1.504
EL65
50
M50
1.059
2.815
4.528
1.736
1.303
1.736
EL65
1.571
3.465
4.528
1.972
1.547
1.972
EL80
1.571
3.465
4.528
2.205
1.839
2.205
EL80
or
or 1
0.783
1.299
2.874
0.551
0.374
0.551
EL30
0.795
1.630
3.268
0.787
0.461
0.787
EL38
63s
M63
212
63
M63
212
75s
M75
1.634
4.134
4.803
2.441
2.059
2.441
EL104
75
M75
1.634
4.134
4.803
2.677
2.283
2.677
EL104
NOTES:
Gland Size does not necessarily equate to the entry thread size
Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
Please note that dimensions (A) and (B) may differ for glands with parallel entry threads. Please refer to our thread data tables for
specific dimensions
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
For Class I Group A locations, the joint made by fitting the gland to the enclosure female thread must comply with standard UL 886
clause 6.4.1 as follows:-
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Design Standard
BS 6121:1989
GLAND MARKING
Example:
BS6121 Part 1 BW [size] [thread] PCGL (or
PEPPERS)
INGRESS
PROTECTION
IP30
MATERIALS
VARIATIONS
All variants of the BW type gland feature a separate armour clamping ring to allow for inspection of the clamped
armour:Brass (BWL)
Integral Earth version for HV applications:
Brass (BWLIE)
OPERATING
TEMPERATURES
options
-100OC to +600OC
THREADS
CLAMPS
plating
accessories
example part
number
Sample: BW K1/ZP/20S/M20
BW:
BW K1 ZP 20s M20 -
Gland
Size
Entry
Threads
Entry
Thread
Length
Max
Across
Corners
Metric
[B]
[A]
Max
Protrusion
Length
Cable Outer
Sheath [D]
Cable Inner
Sheath [C]
Min
Max
Min
Max
Armour Acceptance
Range
Shroud
Size
XZ
Clamp Ring
Version Only
20s
M20
10
24.2
20.0
11.7
16.0
0.90-1.25
0.15-0.35
S22
20
M20
10
29.7
20.0
14.0
21.0
0.90-1.25
0.15-0.50
S27
25
M25
10
45.1
22.0
20.0
27.4
1.25-1.60
0.15-0.50
S36
32
M32
10
50.6
25.0
26.3
34.0
1.60-2.00
0.15-0.55
S41
40
M40
15
60.5
30.0
32.2
40.6
1.60-2.00
0.20-0.60
L55
50
M50
15
71.5
32.0
44.1
53.2
2.00-2.50
0.20-0.60
L65
63
M63
15
88.0
42.0
56.0
65.8
2.50
0.30-0.80
L80
75
M75
15
99.0
50.0
68.0
78.0
2.50
0.30-1.00
L90
80
M80
20
115.2
50.0
72.0
84.0
3.15
0.45-1.00
S104
85
M85
20
115.2
50.0
78.0
90.0
3.15
0.45-1.00
S104
90
M90
20
125.7
50.0
84.0
96.0
3.15
0.45-1.00
S114
100
M100
20
125.7
50.0
90.0
102.0
-3.15
0.45-1.00
S114
NOTES:
Gland Size does not necessarily equate to the entry thread size
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
Full assembly instructions are available upon request, the instructions should be read prior to installation and adhered to in full
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Design Standard
BS EN 50262: 1999
GLAND MARKING
Example:
CWL [size] [thread] PCGL (or Peppers)
INGRESS
PROTECTION
IP66
MATERIALS
VARIATIONS
options
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
Seals
CLAMPS
plating
OPERATING
TEMPERATURES
accessories
example part
number
Gland
Size
Entry Threads
Max
Entry
Max
Thread Across Protrusion
Length Corners Length
[B]
Metric
16
[A]
Min Max
Armour Acceptance
Range
Cable Inner
Sheath [C]
Standard
Min
Max
Shroud
Size
Reduced (R)
Min
Max
XZ
10.3
0.90
0.15-0.35
L24
NPT/BSP
M20
12
or 34
16
26.5
54.0
8.4
9.0
13.5
or
34
16
26.5
54.0
11.7
11.5
16.0
9.4
12.5
0.90-1.25
0.15-0.35
L24
or 34
16
33.0
54.0
14.0
15.5
21.0
12.0
17.6
0.90-1.25
0.15-0.50
L30
20s
M20
12
20
M20
12
6.7
25
M25
34
or 1
16
41.4
54.0
20.0
20.3
27.4
16.8
23.9
1.25-1.60
0.15-0.50
L38
32
M32
1 or 114
16
50.6
60.0
26.3
26.7
34.0
23.2
30.5
1.60-2.00
0.15-0.55
L46
40
M40
50s
M50
50
63s
63
114
16
60.5
67.0
32.2
33.0
40.6
28.6
36.2
1.60-2.00
0.20-0.60
L55
112 or 2
16
71.5
67.0
38.2
39.4
46.7
34.8
42.4
2.00-2.50
0.20-0.60
L65
M50
16
71.5
67.0
44.1
45.7
53.2
41.1
48.5
2.00-2.50
0.30-0.60
L65
M63
2 or 212
19
88.0
69.0
50.1
52.1
59.4
47.5
54.8
2.50
0.30-0.80
L80
M63
212
19
88.0
69.0
56.0
58.4
65.8
53.8
61.2
2.50
0.30-0.80
L80
75s
M75
75
M75
or
112
212
or 3
19
99.0
77.0
62.0
64.8
72.2
60.2
68.0
2.50
0.30-1.00
L90
19
99.0
77.0
68.0
71.1
78.0
66.5
73.4
2.50
0.30-1.00
L90
312
25
115.2
104.0
72.0
77.0
84.0
3.15
0.45-1.00
L104
25
115.2
104.0
72.0
79.6
90.0
3.15
0.45-1.00
L104
80
M80 x 2
3 or
80H
M80 x 2
3 or 312
312
85
M85 x 2
3 or
25
115.2
104.0
78.0
79.6
90.0
75.0
85.4
3.15
0.45-1.00
L104
90
M90 x 2
312 or 4
25
125.7
104.0
84.0
88.0
96.0
3.15
0.45-1.00
L114
90H
M90 x 2
312 or 4
25
125.7
104.0
84.0
92.0
102.0
3.15
0.45-1.00
L114
100
M100 x 2
312 or 4
25
125.7
104.0
90.0
92.0
102.0
87.4
97.4
3.15
0.45-1.00
L114
Gland Size does not necessarily equate to the entry thread size
"XZ" refers to the wire diameter in a woven steel wire armoured cable or the tape thickness in a steel tape armoured cable
Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
Full assembly instructions are available upon request, the instructions should be read prior to installation and adhered to in full
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Design Standard
BS EN 50262: 1999
GLAND MARKING
Example:
MATERIALS
For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (E2W); 316 Stainless Steel (E2WS)
Integral earth version for HV appliances:
Brass (E1WIE); 316 Stainless Steel (E1WIES)
Omission of outer seal:
Brass (D1W); 316 Stainless Steel (D1WS)
options
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
Seals
CLAMPS
plating
OPERATING
TEMPERATURES
accessories
example part
number
Gland
Size
Entry Threads
Entry
Max
Max
Thread Across Protrusion
Length Corners Length
[B]
Metric
16
[A]
Min Max
Armour Acceptance
Range
Cable Inner
Sheath [C]
Standard
Min
Max
Reduced (R)
Min
Max
Shroud
Size
XZ
10.0
0.90
0.15-0.35
L24
NPT/BSP
M20
12
or 34
16
26.5
58.0
4.0
8.4
8.4
13.5
or
34
16
26.5
58.0
8.0
11.7
11.5
16.0
9.4
12.5
0.90-1.25
0.15-0.35
L24
or 34
16
33.0
58.0
6.7
14.0
15.5
21.0
12.0
17.6
0.90-1.25
0.15-0.50
L30
20s
M20
12
20
M20
12
4.9
25
M25
34
or 1
16
41.4
58.0
13.0
20.0
20.3
27.4
16.8
23.9
1.25-1.60
0.15-0.50
L38
32
M32
1 or 114
16
50.6
65.0
19.0
26.3
26.7
34.0
23.2
30.5
1.60-2.00
0.15-0.55
L46
40
M40
50s
M50
50
63s
114
or
112
16
60.5
72.0
25.0
32.2
33.0
40.6
28.6
36.2
1.60-2.00
0.20-0.60
L55
112 or 2
16
71.5
73.0
31.5
38.2
39.4
46.7
34.8
42.4
2.00-2.50
0.20-0.60
L65
M50
16
71.5
73.0
36.5
44.1
45.7
53.2
41.1
48.5
2.00-2.50
0.30-0.80
L65
M63
2 or 212
19
88.0
76.0
42.5
50.1
52.1
59.4
47.5
54.8
2.50
0.30-0.80
L80
63
M63
212
19
88.0
76.0
49.5
56.0
58.4
65.8
53.8
61.2
2.50
0.30-0.80
L80
75s
M75
212 or 3
19
99.0
82.0
54.5
62.0
64.8
72.2
60.2
68.0
2.50
0.30-1.00
L90
75
M75
19
99.0
82.0
60.5
68.0
71.1
78.0
66.5
73.4
2.50
0.30-1.00
L90
80
M80 x 2
3 or 312
25
115.2
110.0
62.2
72.0
77.0
84.0
3.15
0.45-1.00
L104
80H
M80 x 2
3 or 312
25
115.2
110.0
62.2
72.0
79.6
90.0
3.15
0.45-1.00
L104
85
M85 x 2
3 or 312
25
115.2
110.0
69.0
78.0
79.6
90.0
75.0
85.4
3.15
0.45-1.00
L104
90
M90 x 2
312
or 4
25
125.7
110.0
74.0
84.0
88.0
96.0
3.15
0.45-1.00
L114
90H
M90 x 2
312 or 4
25
125.7
110.0
74.0
84.0
92.0
102.0
3.15
0.45-1.00
L114
100
M100 x 2
312 or 4
25
125.7
110.0
82.0
90.0
92.0
102.0
87.4
97.4
3.15
0.45-1.00
L114
NOTES:
Gland Size does not necessarily equate to the entry thread size
"XZ" refers to the wire diameter in a woven steel wire armoured cable or the tape thickness in a steel tape armoured cable
E3* gland size 20, the silicone inner seal only seals to a minimum of 11.0mm and NOT 6.7mm
Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
Full assembly instructions are available upon requests, the instructions should be read prior to installation and adhered to in full
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Design Standard
BS EN 50262: 1999
GLAND MARKING
Example:
MATERIALS
options
For lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (A4L); 316 Stainless Steel (A4LS)
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
Seals
plating
OPERATING
TEMPERATURES
accessories
example part
number
Gland
Size
Entry Threads
Metric
16
Entry
Thread
Length
Max
Across
Corners
[B]
[A]
16
28.0
116
16
Max
Protrusion
Length
Shroud
Size
Min
Max
33.0
4.0
8.4
L24
28.0
33.0
7.2
11.7
L24
33.0
33.0
9.6
14.0
L30
NPT/BSP
M20
12
or 34
or
34
or 34
20s
M20
12
20
M20
12
25
M25
34
or 1
16
41.4
33.0
13.5
20.0
L38
32
M32
1 or 114
16
50.6
33.0
19.5
26.3
L46
40
M40
114 or 112
16
60.5
37.0
23.0
32.2
L55
50s
M50
112 or 2
16
71.5
37.0
28.2
38.2
L65
50
M50
16
71.5
37.0
33.2
44.1
L65
63s
M63
2 or 212
19
88.0
37.0
39.3
50.1
L80
M63
212
19
88.0
37.0
46.7
56.0
L80
63
212
75s
M75
19
99.0
37.0
52.3
62.0
L90
75
M75
19
99.0
37.0
58.1
68.0
L90
80
M80 x 2
3 or 312
25
115.2
50.0
62.3
72.0
L104
85
M85 x 2
3 or 312
25
115.2
50.0
69.1
78.0
L104
or 3
90
M90 x 2
312
or 4
25
125.7
50.0
74.1
84.0
L114
100
M100 x 2
312 or 4
25
125.7
50.0
82.0
90.0
L114
Gland Size does not necessarily equate to the entry thread size
Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables
for specific dimensions
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
Full assembly instructions are avalable upon request, the instructions should be read prior to installation and adhered to in full
http://www.cableglands.com
Peppers Cable Glands Limited 2006
CERTIFication
CENELEC
SIRA00ATEX1094 (Metric Female)
SIRA99ATEX1115U (Non-Metric Female)
I M2 II 2DG E Ex de IandIIC
II 2DG E Ex de IIC (Aluminium)
CSA / A Ex
Class I, Zone 1, Ex de IandIIC
Class I, Division 1and2 ABCD
Class II EFG, Class III
GOST R-Exde IICU
POCC GB 05.B00482
IECEx Ex d IIC / Ex e II / Ex d I
IECEx SIR 05.0042U
INGRESS
PROTECTION
IMPACT RESISTANCE
OPERATING
TEMPERATURES
-50C to +85C
MATERIALS
THREADS
ISO Metric; ET; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
Seals
plating
example part
number
Sample: ARB/NP/M20/050NPT
AR - Adapter/Reducer type
B
NP
M20
050NPT
Metric
M16
Bore
NPT
Bore
ISO Pipe
Bore
ET
Bore
10.0
M20
14.0
12
M25
18.0
34
15.0
12
19.0
34
PG
Bore
8.0
15.0
34
14.0
10.0
19.0
18.0
11
13.5
24.0
13.5
14.0
32.0
16
16.0
M32
24.0
25.0
25.0
114
M40
32.0
114
32.0
114
32.0
112
M50
41.0
112
38.0
112
38.0
41.0
21
21.0
M63
53.0
49.0
49.0
212
53.0
29
29.0
M75
64.0
212
60.0
212
60.0
64.0
M80 x 2.0
69.0
75.0
88.0
312
100.0
M85 x 2.0
73.0
312
M90 x 2.0
78.0
M100 x 2.0
36
38.0
75.0
42
45.0
88.0
48
50.0
100.0
88.0
All Dimensions are in Millimetres
NOTES:
Full installation instructions are supplied with adaptors and reducers, the instructions must be read prior to installation and
adhered to in full
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the adaptor or reducer is to be fitted must comply with clause 5.3 of
EN 50018:2000 (clause 5.3 IEC 79-1)
For NEC/CEC Explosion Proof applications an engagement of at least 8 full threads must be achieved for parallel threads and 5 full
threads must be achieved for tapered threads
Where AR adaptors and reducers are fitted into non-metallic Increased Safety Exe enclosures they must be included within the
earth circuit of the system
316 Stainless Steel versions do not feature a marking band. This reduces the overall length of reducers by 5mm, it does not affect
the overall length of Adaptors
Adaptors are used where the thread size of the cable gland or connection device is larger than, or of an equivalent size to the
entry thread of the enclosure
Reducers are used to reduce the entry thread of an enclosure to accept a cable gland or connection device with a smaller thread
http://www.cableglands.com
Peppers Cable Glands Limited 2006
CENELEC
SIRA00ATEX3091 (Metric Female)
SIRA99ATEX3116U (Non-Metric Female)
II 2DG E Ex e II
CSA / A Ex
Class I, Zone 1, Ex e II
Class I, Division 2 ABCD
Class II EFG, Class III
INGRESS
PROTECTION
IMPACT RESISTANCE
7Nm
OPERATING
TEMPERATURES
-50C to +85C
MATERIALS
THREADS
ISO Metric; ET; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
Seals
example part
number
Sample: ARN/M20/M25
ARN - Body material (Nylon)
M20 - Male thread size
M25 - Female thread size
AVAILABLE THREAD SIZES AND CORRESPONDING BORE SIZE
Metric
Bore
NPT
Bore
ISO Pipe
Bore
ET
Bore
PG
Bore
M16
9.3 9 9.0
M20
11.0
12
12.0
12
12.0
34
11.0
11
10.0
M25
16.0
34
13.0
34
13.0
16.0
13.5
11.5
M32
21.0
18.0
18.0
114
21.0
16
13.5
M40
31.0
114
33.0
114
33.0
112
31.0
21
19.0
40.0
112
38.0
112
38.0
40.0
M50
29
28.0
36
37.0
42
44.0
Full installation instructions are supplied with adaptors and reducers, the instructions must be read prior to installation and
adhered to in full
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
Adaptors are used where the thread size of the cable gland or connection device is larger than, or of an equivalent size to the
entry thread of the enclosure
Reducers are used to reduce the entry thread of an enclosure to accept a cable gland or connection device with a smaller thread
http://www.cableglands.com
CERTIFication
CENELEC
SIRA00ATEX1098 (Metric Female)
SIRA99ATEX1117U (Non-Metric Female)
II 2DG E Ex d IIC
CSA / A Ex
Class I, Zone 1, Ex d IIC
Class I, Division 2 ABCD
Class II EFG, Class III
GOST R-Exde IICY
POCC GB 05.B00482
APPLICATIONS
To avoid relying on the contact between cable termination and equipment enclosure for grounding the cable
armour, an insulated adaptor can be fitted to both ends of the cable with a grounding device (i.e. earth tag/lug)
fitted between the adaptor and the termination. The armour current can then be taken from the grounding device
to ground in a controlled, positive manner that can be inspected easily.
Single Point Grounding:- In many applications it is sufficient to ground the cable armour at one end. For single point grounding the
insulated adaptors would again be used at both ends of the cable but with the earth tag fitted only to the end
where grounding is required.
Single Point Grounding can:- reduce the circulating currents that can cause heating of high capacity cables.
- reduce the risk of damage to electronic equipment within the enclosure in the event of a short circuit to ground
through the enclosure.
- reduce the problems of electrical noise on the armour affecting the clean earth required for some sensitive
instruments.
Electrical properties of insulating material
- Dielectric strength: 90KV/mm
- Volume resistivity: 8.6 x 10x14 O/cm
- Minimum thickness of insulator: 5mm +/- 1mm
- 2KV Wet Withstand Tested
INGRESS
PROTECTION
IMPACT RESISTANCE
7Nm
OPERATING
TEMPERATURES
-20C to +60C
MATERIALS
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
plating
example part
number
Sample: IA/NP/M20/050NPT
IA
NP
M20
050NPT
Metric
Hex A/F
Hex A/C
Total Length
Male Length
Female Depth
Bore
M20
30.5
35.5
54.0
16.0
17.0
13.5
M25
37.6
43.2
54.0
16.0
17.0
19.0
M32
47.2
54.3
54.0
16.0
17.0
25.0
M40
55.9
64.1
54.0
16.0
17.0
30.0
M50
70.1
80.8
54.0
16.0
17.0
40.5
M63
80.0
92.0
54.0
16.0
17.0
53.0
M75
95.3
109.5
54.0
16.0
17.0
65.0
M80 x 2.0
100.0
114.0
63.0
20.0
22.0
70.0
M85 x 2.0
106.4
114.0
63.0
20.0
22.0
75.0
M90 x 2.0
106.4
114.0
63.0
20.0
22.0
80.0
NOTES:
Full installation instructions are supplied with insulated adaptors, the instructions must be read prior to installation and adhered to
in full
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the adaptor is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1)
http://www.cableglands.com
Peppers Cable Glands Limited 2006
CERTIFication
CENELEC
SIRA00ATEX1094 I M2 II 2DG E Ex de IandIIC
SIRA00ATEX1094 II 2DG E Ex de IIC (Aluminium)
CSA / A Ex
Class I, Zone 1, Ex de IandIIC
Class I, Division 1and2 ABCD
Class II EFG, Class III
GOST R-Exde IICY
POCC GB 05.B00482
IECEx Ex d IIC / Ex e II / Ex d I
IECEx SIR 05.0042U
INGRESS
PROTECTION
IMPACT RESISTANCE
OPERATING
TEMPERATURES
-50C to +85C
MATERIALS
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
Seals
plating
example part
number
Sample: SPMH/NP/M20
SPMH - Stopping Plug type and body material (Brass)
NP - Nickel plating
M20 - Male thread size
Metric
M16
Dim Ref
NPT
Dim Ref
ISO Pipe
Dim Ref
PG
Dim Ref
M20
12
M25
34
M32
13.5
M40
114
114
16
M50
112
112
21
M63
29
212
36
42
48
M75
212
M80 x 2.0
M85 x 2.0
312
M90 x 2.0
M100 x 2.0
12
34
11
DIMENSIONS
Dimension Reference
Head Diameter Minimum 6.0mm larger than the major thread diameter
6.0
8.0
10.0
10.0
10.0
10.0
10.0
Total Length
21.5
21.5
21.5
24.5
25.5
29.0
39.0
Thread Length
16.0
16.0
16.0
19.0
22.0
23.5
33.5
NOTES:
SPMH type stopping plugs are designed for use within either clearance holes or parallel threaded entries, for taper threaded entries
we would recommend the use of SPA type stopping plugs
Full installation instructions are supplied with stopping plugs, the instructions must be read prior to installation and adhered to in
full
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the stopping plug is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1)
For NEC/CEC Explosion Proof applications an engagement of at least 8 full threads must be achieved for parallel threads and 5 full
threads must be achieved for tapered threads
Where metallic stopping plugs are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth
circuit of the system
http://www.cableglands.com
Peppers Cable Glands Limited 2006
CERTIFication
CENELEC
SIRA00ATEX3091 II 2DG E Exe II
CSA / A Ex
Class I, Zone 1, Ex e II
Class I, Division 2 ABCD
Class II EFG, Class III
INGRESS
PROTECTION
IMPACT RESISTANCE
7Nm
OPERATING
TEMPERATURES
-50C to +85C
MATERIALS
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
Seals
example part
number
Sample: SPMHN/M20
SPMHN - Stopping Plug type and body material (Nylon)
M20 - Male thread size
Metric
Dim Ref
NPT
Dim Ref
PG
Dim Ref
M16
M20
12
M25
34
11
M32
13.5
M40
114
16
M50
112
21
M63
29
212
M75
36
42
48
DIMENSIONS
Dimension Reference
Head Diameter
6.0
10.0
Total Length
21.5
21.5
21.5
Thread Length
16.0
16.0
16.0
NOTES:
SPMHN type stopping plugs are designed for use within either clearance holes or parallel threaded entries, for taper threaded
entries we would recommend the use of SPA type stopping plugs
Full installation instructions are supplied, the instructions must be read prior to installation and adhered to in full
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
http://www.cableglands.com
Peppers Cable Glands Limited 2006
CENELEC
SIRA99ATEX1113 II 2DG E Ex d IIC
CSA / A Ex
Class I, Zone 1, Ex d IIC
Class I, Division 1 & 2 ABCD
Class II EFG, Class III
IECEx Ex d IIC
IECEx SIR 05.0042U
INGRESS
PROTECTION
IMPACT RESISTANCE
7Nm
OPERATING
TEMPERATURES
-50C to +85C
MATERIALS
THREADS
ISO Metric; ET; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
plating
example part
number
Sample: SPAB/NP/M20
SPA - Stopping Plug type (Externally accessible hexagon recess)
B
- Body material (Brass)
NP - Nickel plating
M20 - Male thread size
Metric
M16
Dim Ref
NPT
Dim Ref
ISO Pipe
Dim Ref
PG
Dim Ref
M20
12
M25
34
M32
13.5
M40
114
114
16
M50
112
112
21
M63
29
212
36
42
48
M75
212
M80 x 2.0
M85 x 2.0
312
M90 x 2.0
M100 x 2.0
12
34
11
DIMENSIONS
Dimension Reference
Length (min)
6.0
8.0
16.0
17.0
10.0
10.0
10.0
17.0
14.0
16.0
10.0
10.0
10.0
18.0
22.0
25.0
NOTES:
Full installation instructions are supplied with stopping plugs, the instructions must be read prior to installation and adhered to in
full
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
For Flameproof Exd applications the female thread into which the stopping plug is to be fitted must comply with clause 5.3 of EN
50018:2000 (clause 5.3 IEC 79-1)
For NEC/CEC Explosion Proof applications an engagement of at least 8 full threads must be achieved for parallel threads and 5 full
threads must be achieved for tapered threads
http://www.cableglands.com
Peppers Cable Glands Limited 2006
CERTIFication
CENELEC
SIRA99ATEX3050U I M2 II 2DG EExe I/II; II 2DG E
Exe (Glass Filled Nylon and Aluminium)
CSA / A Ex
Class I, Zone 1, Exe II; Class I Division 2, Groups
ABCD
GOST R-Exe IIU
POCC GB 05.B00482
APPLICATION
Internal Dust Seal provides ingress protection to IP66 and 4x, with the largest possible pore size to aid draining,
whilst retaining filtration capabilities that remove debris from the moisture and retains it on the surface where
it can easily be removed with compressed air. Additionally the structural strength and chemical resistance
characteristics of the material enable the filter to meet the requirements of hazardous area installations
Castellated Locknut allows moisture to pass between the locknut and the enclosure, draining via holes in the
thread without any build up of moisture in the bottom of the enclosure
Captive O Ring Seal is located within a recess on the face of the breather drain again optimising ingress
protection, ensuring the oring is not displaced during installation and helping protect the O ring from the
environmental damage
External Drainage via two ports optimises ingress protection without compromising the draining capabilities
INGRESS
PROTECTION
IMPACT RESISTANCE
OPERATING
TEMPERATURES
-50C to +85C
MATERIALS
VARIATIONS
Clearance hole (10): 10mm length of thread, supplied complete with a castellated locknut and having 2 holes in
the thread wall positioned directly opposite each other
Threaded Entry (15 or 15NL): 15mm length of thread, either supplied with (15) or without castellated locknut
(15NL) and having 3 holes in the thread wall, offset to provide a 9mm range to accommodate differing wall
thickness
THREADS
ISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
Seals
plating
example part
number
Sample: ACDPEB/NP/M20/15
ACDPEB - Breather Drain type and material (Brass)
NP - Nickel plating
M20 - Male thread size
15 - Male thread length (15mm) and drain holes in thread (x 3 offset)
DIMENSIONAL DATA
Size
Hex A/F
Hex A/C
M20 - 12 NPT
28.6mm
32.9mm
M25 - 34NPT
34.9mm
40.2mm
Thread Length
Head Length
10 (2 Hole) or 15 (3 Hole)
15mm
NOTES:
30% glass filled nylon variations are only available with 15mm length of thread version and are supplied with or without a brass
castellated nut
Full installation instructions are supplied with the breather drain, the instructions must be read prior to installation and adhered to
in full
Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
Where metallic breather drains are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth
circuit of the system
http://www.cableglands.com
Peppers Cable Glands Limited 2006
Accessories:- General
Part of our Accessories Range
2006 Catalogue Page 7.4.1
A full range of accessories including locknuts, earthtags, sealing washers, serrated washers and shrouds for use with all
our cable glands
AVAILABILITY
ACCESSORY TYPE
GLAND TYPES/SIZE
THREAD TYPES
METRIC
NPT
BSP
PG
FRENCH
Locknuts provide a method of securing a threaded entry component into a piece of equipment
Brass (ACBLN)
All
M16 to M100
12 to 4
12 to 4
PG7 to PG48
F48
M16 to M100
12 to 4
12 to 4
PG7 to PG48
F48
Aluminium
M20 to M63
Nylon (ACNLN)
Nylon
M20 to M63
PG7 to PG48
Steel (ACMLN)
Industrial
M20 to M50
All
M16 to M100
12 to 4
12 to 4
PG7 to PG48
F48
Aluminium
M20 to M63
IP Sealing Washers are fitted between an entry component and the equipment to maintain the IP rating of the equipment
Nylon (ACNSW)
All
M16 to M100
12 to 4
12 to 4
PG7 to PG48
F48
All
M20 to M75
Serrated Star Washers can be used in conjunction with a locknut to provide additional fixing security and improve bonding
316 Stainless Steel (ACSSW)
All
M16 to M100
12 to 4
12 to 4
PG7 to PG48
F48
All
M20 to M75
Shrouds can be used to protect the gland from the surrounding environment
PVC (ACSPVC)
16 to 100
PCP (ACSPCP)
16 to 85
LSOH (ACSSIO)
16 to 85
Shrouds are not available for all glands, please see specific gland page for exact details
NOTES:
As standard ISO Metric threads are supplied with a 1.5mm pitch up to and including M75 and a 2.0mm pitch for sizes above M75
http://www.cableglands.com
2006 Catalogue Page 7.4.1
ISO
METRIC
IEC 60423
1993
NPT
ANSI
B1.20.1
1983
NPS
ANSI
B1.20.1
1983
Thread Ref
Size
Major
TPI
Pitch
Thread Length
M16
16 x 1.5
15.97
16.93
1.50
16.0
M20
20 x 1.5
19.97
16.93
1.50
16.0
33.0
M25
25 x 1.5
24.97
16.93
1.50
16.0
41.4
M32
32 x 1.5
31.97
16.93
1.50
16.0
50.6
M40
40 x 1.5
39.97
16.93
1.50
16.0
60.4
M50
50 x 1.5
49.97
16.93
1.50
16.0
71.5
M63
63 x 1.5
62.97
16.93
1.50
19.0
88.0
M75
75 x 1.5
74.97
16.93
1.50
19.0
99.0
M80
80 x 2.0
19.97
12.70
2.00
25.0
115.2
M85
85 x 2.0
84.97
12.70
2.00
25.0
115.2
M90
90 x 2.0
89.97
12.70
2.00
25.0
125.7
M100
100 x 2.0
99.97
12.70
2.00
25.0
125.7
26.5
050NPT
12
21.22
14.00
1.81
19.9
075NPT
34
26.57
14.00
1.81
20.1
33.0
100NPT
33.23
11.50
2.20
25.0
41.4
125NPT
114
41.99
11.50
2.20
25.6
50.6
150NPT
112
48.05
11.50
2.20
26.0
60.5
200NPT
60.09
11.50
2.20
26.9
71.5
250NPT
212
72.70
8.00
3.18
39.9
88.0
300NPT
88.61
8.00
3.18
41.5
99.0
350NPT
312
101.36
8.00
3.18
42.8
115.2
400NPT
113.97
8.00
3.18
44.0
125.7
050NPS
12
20.90
14.00
1.81
19.9
26.5
075NPS
34
26.26
14.00
1.81
20.1
33.0
100NPS
32.84
11.50
2.20
21.5
41.4
125NPS
114
41.61
11.50
2.20
25.6
50.6
150NPS
112
47.67
11.50
2.20
26.0
60.5
200NPS
59.72
11.50
2.20
26.9
71.5
250NPS
212
72.16
8.00
3.18
39.9
88.0
300NPS
88.06
8.00
3.18
41.5
99.0
350NPS
312
100.78
8.00
3.18
42.8
115.2
400NPS
113.43
8.00
3.18
44.0
125.7
PG7
PG7
12.50
20.00
1.27
16.0
26.5
PG9
PG9
15.20
18.00
1.41
16.0
26.5
PG
DIN 40430
1971
(W/D)
PG11
PG11
18.60
18.00
1.41
16.0
26.5
PG13.5
PG13.5
20.40
18.00
1.41
16.0
26.5
PG16
PG16
22.50
18.00
1.41
16.0
33.0
PG21
PG21
28.30
16.00
1.59
16.0
41.4
PG29
PG29
37.00
16.00
1.59
16.0
50.6
PG36
PG36
47.00
16.00
1.59
16.0
60.5
PG42
PG42
54.00
16.00
1.59
16.0
71.5
PG48
PG48
59.30
16.00
1.59
16.0
88.0
ISO Pipe
Parallel
F48
PG48 (FR)
59.61
11.00
2.31
26.9
71.5
050BSP
12
20.96
14.0
1.81
19.9
26.5
ISO R/7;
075BSP
34
26.44
14.0
1.81
20.1
33.0
100BSP
33.25
11.0
2.31
25.0
41.4
BS2779
125BSP
114
41.91
11.0
2.31
25.6
50.6
(BSPP, G,
R, PF)
150BSP
112
47.80
11.0
2.31
26.0
60.5
200BSP
5961
11.0
2.31
26.9
71.5
250BSP
212
75.18
11.0
2.31
39.9
88.0
050BST
12
20.96
14.0
1.81
19.9
26.5
ISO Pipe
Taper to
075BST
34
26.44
14.0
1.81
20.1
33.0
100BST
33.25
11.0
2.31
25.0
41.4
125BST
114
41.91
11.0
2.31
25.6
50.6
150BST
112
47.80
11.0
2.31
26.0
60.5
(BSPT, GK)
200BST
5961
11.0
2.31
26.9
71.5
250BST
212
75.18
11.0
2.31
39.9
88.0
ISO R/7;
BS21
2006 Catalogue
Ingress Protection
It is essential when selecting cable glands and/or accessories to ensure that the products will maintain the IP rating of the
equipment and the integrity of the installation.
IP Codes are based on the IEC Standard 529, degrees of protection provided by enclosures.
In most cases Peppers cable glands will maintain Ingress Protection of the equipment into which they are installed to:
IP 66
IP 67
IP 68
Protected against heavy seas or powerful jets of water. Prevents ingress sufficient to cause harm
DTS 01
This test was originally constructed by Shell and Esso in the UK to simulate the routine deluging of electrical equipment on
offshore installations
(Deluge)
IP 54
As a general guide to selecting the sealing method that is most likely to maintain the required IP rating for different entry
types, we recommend:
Clearance Holes - Integral O ring seal or nylon IP washer
Parallel Threaded Entries - Integral O ring seal, IP washer or non-hardening thread sealant
Taper Threaded Entries - Non-hardening thread sealant
16
20s
20
25
32
40
50s
50
63s
63
75s
75
80
85
90
100
Entry
Thread
M20
M20
M20
M25
M32
M40
M50
M50
M63
M63
M75
M75
M80
M85
M90
M100
164
160
250
400
750
1095
1415
1295
2345
2006
1980
2200
3970
3300
4314
3537
E1WF
144
130
186
262
420
672
980
758
1410
1140
1745
1375
3255
2655
3559
2795
CWLE
134
124
180
262
402
680
1040
764
1410
1185
1730
1495
3130
2500
3280
3054
A2LF
A2LDSF
RG22E
142
144
158
256
298
556
980
796
1410
1170
1565
1310
2130
1980
2360
2285
6
-
8
16
28
35
-
65
-
74
-
-
-
-
-
-
84
90
94
152
176
332
570
458
850
684
954
764
1430
1290
1510
1485
CR-CB
165
165
240
400
725
1060
1435
1340
2100
2025
2330
2240
4985
4065
5215
4410
2006 Catalogue
II
CR-XB
-
115
170
260
384
585
-
700
-
1040
-
1150
2730
2255
2790
2450
CR-UB
-
180
260
385
570
885
1035
1160
1555
1695
1750
1880
3860
3250
3985
3580
CR-SB
-
-
215
340
485
730
-
875
-
1355
-
1475
3415
2830
3985
3580
BW
52
84
140
180
436
480
910
1070
1770
-
WARNING
Peppers cable glands should not be used within any application other than
those specified for each product, unless Peppers Cable Glands issue a statement
in writing that the product is suitable for the specified application. For further
information on each product, we refer you to the specific Assembly Instructions
and General Arrangement drawings, which are available on request. Using the
links on our web site catalogue pages and instructions may be downloaded from
the internet. Peppers Cable Glands take no responsibility for any damage, injury
or other consequential loss caused where the glands are not installed or used
according to our Assembly Instructions.
SPARE PARTS
Apart from the accessories listed in this catalogue, Peppers does not supply spare
parts for any of its glands. Glands are designed so that no part from another
manufacturers gland will fit Peppers gland. If part of a gland needs to be
replaced for any reason, the user should ensure an entire new gland is fitted.
DIMENSIONAL DATA
The dimensions shown within this catalogue may vary due to material availability.
CE CONFORMITY
Copies of Peppers CE declarations regarding LVD, EMC and ATEX directives are
available upon request. BS EN 50262 classification with regard to mechanical and
electrical properties of cable glands is available upon request.
Global Approvals
Universal Solutions
www.cableglands.com
http://www.cableglands.com
www.cableglands.com