Nonintrusive partial discharge measurements on


high voltage switchgear
Conference PaperJanuary 1997 with 8 Reads
DOI: 10.1049/ic:19961073 Source: IEEE Xplore
Conference: Monitors and Condition Assessment Equipment (Digest No. 1996/186), IEE
Colloquium on

1st P. Brown

Abstract
Partial discharges in high voltage metal-clad switchgear can result in catastrophic
failure of the individual plant and in some cases of the substation. There has been a
need for detection and location of the damaging discharges without the plant or
substation being taken out of service. The conventional partial discharge detection
technique requires direct connection to the high voltage busbars and therefore is
limited in application. The EA Technology Partial Discharge Locator and Partial
Discharge Monitor are designed to full this important requirement. These
instruments are complemented by ultrasonic detection to provide a comprehensive
service to both Regional Electricity Companies and industry. The Partial Discharge
Locator and Partial Discharge Monitor both use the Transient Earth Voltage (TEV)
measurement technique. The Partial Discharge Locator is a portable instrument
used to survey switchrooms taking approximately an hour to survey a ten panel
switchboard. The Partial Discharge Monitor is installed for a week monitoring a
switchboard and provides a means of detecting intermittent partial discharge
activity which may be missed by a survey with the Partial Discharge Locator

Do you want to read the rest of this publication?


Request full-text

Citations

References

"In TEV measurement, the non-intrusive sensor is mounted at the outside


surface of grounded metallic enclosure of HV apparatus. The sensor
detects TEV signal which is produced by radiating electromagnetic waves
of PDs inside metal enclosure [5, 8]. To illustrate this idea, a laboratory test
was set up as shown inFig.I, where a PD generator was placed inside a

https://www.researchgate.net/publication/3697062_Nonintrusive_partial_discharge_measurements_on_high_voltage_switchgear

1/3

6/22/2016

Nonintrusivepartialdischargemeasurementsonhighvoltageswitchgear
metallic enclosure. "

Recognition of partial discharge using wavelet entropy and neural network for TEV measurement
[Show abstract]

Full-text Conference Paper Oct 2012


Guomin Luo

DaMing Zhang

Read full-text

"As mentioned in many papers [2], [17], PDs inside the metal enclosure
generate radiating electromagnetic waves which duce TEV on the outside
surface of the grounded metal cabinet . To illustrate this idea, a laboratory
test was set up as shown inFig. "

TimeFrequency Entropy-Based Partial-Discharge Extraction for Nonintrusive Measurement


[Show abstract]

Full-text Article Oct 2012 IEEE Transactions on Power Delivery


Guomin Luo

Daming Zhang

YongKwee Koh

+1 more author...

KimTeck Ng

Read full-text

Partial discharge and electrical equipment insulation condition assessment


[Show abstract]

No preview Article Nov 2005 IEEE Transactions on Dielectrics and Electrical Insulation
G.C. Stone
Read
Show more

Note: This list is based on the publications in our database and might not be exhaustive.

Similar publications

Research on the UHF Microstrip Antenna for Partial Discharge Detection in High Voltage
Switchgear
No preview Article Jun 2016 Przeglad Elektrotechniczny
Hanwu LUO

Fuzzy Theory-Based Partial Discharge Technique for Operating State Diagnosis of High-Voltage
Motor
No preview Article Jun 2016 International Journal of Fuzzy Systems
Hong-Chan Chang

Shang-Chih Lin

Cheng-Chien Kuo

Chun-Yu Lin

https://www.researchgate.net/publication/3697062_Nonintrusive_partial_discharge_measurements_on_high_voltage_switchgear

2/3

6/22/2016

Nonintrusivepartialdischargemeasurementsonhighvoltageswitchgear

A fiber optic sensor for the detection of Partial Discharge within the High Voltage power
transformer
No preview Chapter May 2016
B Sarkar

C Koley

N Roy

P Kumbhakar

Data provided are for informational purposes only. Although carefully collected, accuracy cannot be guaranteed. The impact factor represents a rough estimation of the
journal's impact factor and does not reect the actual current impact factor. Publisher conditions are provided by RoMEO. Differing provisions from the publisher's actual
policy or licence agreement may be applicable.

2008-2016 researchgate.net. All rights reserved.

About usContact usCareersDevelopersNewsHelp CenterPrivacyTerms | AdvertisingRecruiting

https://www.researchgate.net/publication/3697062_Nonintrusive_partial_discharge_measurements_on_high_voltage_switchgear

3/3

You might also like