You are on page 1of 2
Technical specification CRYO AB HIGH PRESSSURE ISO TANK CONTAINER Type 182-K2SP-05 2591 2430 The Cryo High Pressure ISO Tank Container Dimensions 182-K2SP-05 is designed for intermodal transport of Overall dimension deeply refrigerated, liquefied non-flammable gases (Ix w xh) 6058 x 2438x2591 mm such as oxygen, nitrogen or argon. 20x8x86 feet The Cryo High Pressure ISO Tank Container Volume design conforms to the requirements of ADR/RID Te eeralane about Fst “ihe product class 2 No. 7 (a). The IMO tank type 7 Max filling ratio. a i” fequitements are also fulfilled The Cryo High Pressure ISO Tank Container is ofa Pressure double-shell vacuum-perlite-insulated construction, __ Max working pressure (g) 48 Ba The outer shell is directly supported by the end s frames, resulting in a robust, lightweight beam Weight concept. The frame conforms to the ISO 1946//III ICC Gross weight approved 30480 kg standard and the CSC requirements, Tare weight 6600 kg ‘Max payload 21680 kg The Cryo High Pressure ISO Tank Container lockable contral cabinet is located an the lower Product realted weight longside and is protected by a crash-frame. The Product Filing ratio” Payload Gross weight armature system is easily operated and the cabinet (90) {kg] {kg] includes a stainless steel drip pan. Nitrogen. 95 13.860 20.460 ‘Oxygen 95 19550 26150 The Cryo High Pressure ISO Tank Container can Argon 3 23.840 30.440 further be equipped with a cryagenic pump and a flow metering system, each including a lockable cabinet YE Technical specification CRYO AB ae eon Symbol Function Symbol Function 43 illing/emptying V1 Bottom illvave AS Emptying through pump ——¥2_—‘Topiillvalve 25 Analysisconnection (gas)_—-V3_—_—Shutolf gud = v6 Trycock valve 85 Checkvalve Vit Yacuumtestvalve hal les in vyer_gyee 811 Lines safety valve V13_ Pressure build-up valve x Lares] [oles 812 Lines safety value 20° Liquid to pump TT te = tar V1 Reluin fiom pump titer ¥28-—_Drainvalve / lose ; Vi2_—shutolf analysis vale M1 Liquidevel gauge V33_— Shutoff analyss valve ” M2 Tank pressure 35 Liquid from pump. MT Pump pressure gauge va Pressure build-up valve hh? ‘M16 Customer tank pressure from pump ‘es vad Plot valve - 49 Shut-off oad valve Pump 50 instrument valve / 1 VSI iastument valve / 1 wa s1 Safety valve, inner vessel V52___ Instrument valve / M1 at 52 Safety valve, outer tank rain [5 S10 Road valve 8 ‘Shut-off liquid Holding time Options Holding time (854% LIN) 20 days Pressure increase 0 - 4.5 bar at 95% filling ratio Net evaporation rate Less than 0.6% / 24h (oxygen) Other data Inner vessel material Austenitic stainless steel Outer jackel material Mild steel International approvals ADR/RID, IMO 7, CSC, UIC, 150 1496/11, TIR National approvals DE (GGVS, GGVE included), OK, GB, NO, SE Painting Anti-corrosion treatment, primer and top coat in white color SE Ciyo AB= Box 8887 - SE-402 72 Gothenburg Sweden Phone: +46 31,646800 Telefax: +46,37.532220 Approvals for national use in most European countries Hose carrier Pump with ¥/0 starter and automatic phase selector Pressure and temperature sensing switch for protection of the pump Stainless stee! outer jacket Flow metering system Pressure raise regulator + Customer logo and color + Grappler arm profiles (located on upper tank part) wiwwccryo.se

You might also like