You are on page 1of 19

EL E G A N T

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

EMBEDDED SOLUTIONS

About EES Tech Center:


EES Tech Center is a training division from

ELEGANT EMBEDDED SOLUTIONS

Pvt. Ltd. It has been launched to provide application oriented training and academic project
training on embedded systems with micro controllers as per new trends in embedded systems
for the beneficial of engineering students and working professionals.

ELEGANT EMBEDDED SOLUTIONS Pvt. Ltd. is Hyderabad based company. We are


into providing embedded software and hardware solutions to the industry applications based
on microcontrollers. EES is empowered with young and dynamic Professional Embedded
design engineers. We aim to utilize our experience, hard work and dedication to make smart,
economic and efficient products.
We are expertise in many microcontrollers customized solutions based on 8 bit to 32 bit
controllers. We have been working with cutting edge technologies like RFID, GSM,
BLUETOOTH and Biometrics etc.
Our design expertise included but not limited to custom design projects, reverse engineering,
automation, data loggers, web based applications, high power machines controllers, and solar
based products and LED displays.
We have a dedicated training wing EES Tech Center, which offers quality trainings in
embedded systems with various micro controllers to meet the current industrial requirements.
At EES Tech Center we provide application oriented practical training, workshops on
microcontrollers for industry R&D people, engineering college faculties and students,
Hobbyist and Electronics Enthusiasts. We have experienced embedded systems professional
trainers to give hands on training on various major micro controllers like 8051, PIC, AVR,
ARM7, MSP430, ARM9, etc.

We have also our own user friendly embedded development boards which are helpful to
reduce your developing time and cost for your products. We also provide academic live
projects in EMBEDDED SYSTEMS, MATLAB and VLSI for B.Tech and M.Tech
engineering students and supply projects for various institutes and engineering colleges.
Ph: 9985784340, 9396671541
Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

Why to choose EES Tech Center:

Highly experienced own R&D team.

Projects with real time approach to meet current trends of Industries

Application oriented practical training with latest trends in Embedded systems

Uniqueness in project designing and projects will be delivered within time with
guaranty output.

Experienced team on wide range of micro controllers like


ATMEL controllers 89CXX,89S51/52: Philips controllers
P89v51RD2,P89V52x2fn Nuvoton, Winbond, Megawin controllers: AVR
controllers ATMEGA8515,16L,32L PIC controllers PIC16F series,18F series,
MSP430, ARM7 LPC2148,LPC2129 and ARM9.

Working on many new cutting edge technologies in embedded systems.

Worked on different protocols like CAN, RS485, SPI, I2C, etc.

Own development boards, modules and PCBs.

Training with our own user friendly Micro controller development boards
On time delivery.
Instantaneous/instant live technical support from our experienced R&D Team.
Projects with latest technologies like Android, Smart Phone, GPRS, Ethernet,
etc.

Ph: 9985784340, 9396671541


Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

EMBEDDED SOLUTIONS

EEE PROJECTS
IEEE & JOURNAL BASED PROJECTS
Project
code
IJEE01

Title of the Project

Description

Distribution Transformer
Monitoring Using GSM
Technology

IJEE02

Prepaid Energy Meter with GSM


technology

IJEE03

Bluetooth remote home


automation system using android
application.
Substation monitoring and
controlling using GSM

In this we will monitor transformer parameters


like current, voltage and temperature, if any of
these parameters found abnormal then this
systems sends SMS alert to user.
the GSM technology is used so that the consumer
would receive messages about the consumption
of power (in watts) and if it reaches the
minimum amount, it would automatically alert
the consumer to recharge
With this we can control home appliances from
our android phone. This safe and secure.

IJEE04

IJEE05

IJEE06

IJEE07

IJEE08

IJEE09

IJEE10

Low cost wireless sensor network


in field operation monitoring of ac
motor
Applied research of the intelligent
temperature-controlled speed
adjustable motor in radiator fan
Electronic energy meter with
instant billing

Remote power on/off control and


current measurement for home
electric outlets based on a lowpower embedded board and
ZIGBEE
Energy saving project for heating
system with ZigBee wireless
control network
Implementation of ZIGBEE-GSM
based home security monitoring
and remote control system

Substation parameters are monitored and it also


send alert message when these parameters are
abnormal
The main aim of this project is to monitor the
operation conditions of single-phase AC motors
In this project the speed of the FAN will be
controlled automatically based on current
temperature.
This paper presents automated billing of energy
meter. It is just like postpaid mobile connection.
This is useful for billing purpose in electricity
board authority.
We can control the home appliances through
ZigBee remote and this system will display the
power consumed by the loads.

The main of this project is to develop energy


saving heating system using ZigBee wireless
technology
The main aim of this project is to develop a
security and control automation system by which
we can control and monitor the status of home
appliances
Ph: 9985784340, 9396671541
Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

IJEE11

IJEE12

IJEE13

IJEE14

IJEE15

IJEE16

Automation of residential
electricity cut off using network
based embedded controller
Design of intelligent streetlight
monitoring system based on micro
controller
GSM-based wireless home
appliances monitoring & control
system

Real-Time Atomization Of
Agricultural Environment for
Social Modernization of Indian
Agricultural System
Method of Measuring Power
Quality and Development of
Monitor Device
A novel technique of ac power
control using micro controller
based inverter

PE01

Design of controlled DC voltage


regulator using semi converter

PE02

Design of controlled DC voltage


regulator using full wave
converter
Industrial battery charger by
thysitor firing angle control

PE03

PE04

Dual converter using thyristors

PE05

Single phase H-bridge inverter


with PWM technology using
microcontroller

PE06

Single phase sine wave PWM H-

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

The main aim of this project is to develop the


automation system for residential electricity cut
off using network based embedded controller
The main aim of this project is to design an
intelligent streetlight monitoring system for
power saving
The main aim of this project is to develop a
system, which uses Mobile technology that keeps
monitoring of the various appliances, and will
control the operation of these appliances with
respect to the signal sent by the mobile
The main of this project is to control the
agriculture motor using mobile and also to protect
the motor
The transmission line voltage, current, and power
factor, active power and reactive power are
measured and displayed on the LCD
The main aim of this work is to design a simple
low cost AC voltage controller used to
Control AC loads which doesnt demand very
high precisions
230v ac is converted in to dc using SCR's and the
required firing pulses for the SCR's are given by
the microcontroller. Only 2 SCR's and 2 diodes
will be there in the converting circuit.
230v ac is converted in to dc using SCR's and the
required firing pulses for the 4 SCR's are given by
the microcontroller.
230v ac is converted in to dc using SCR's. This dc
is used to charge the batteries. The required firing
pulses for the SCR's are given by the
microcontroller. 4 SCR's will be there in
converting circuit.
Single phase dual converter consists of a pair of
thyristor controlled bridge (4 SCRs X 2). The
output of this bridge is given to a DC motor
which can be made to run in either direction with
different speed levels by changing the firing
angle.
In this dc is voltage is converted into A.C by
MOSFET bridge. Here PWM signals are
generated by controller and are given to
MOSFET bridge and variable output voltages are
generated which can be observed by seeing
brightness of the bulb.
In this dc is voltage is converted into A.C by
Ph: 9985784340, 9396671541
Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS
bridge inverter using micro
controller
PE07
PE08

SPWM space vector pulse width


modulation
Step down cyclo converter using
dual converter SCR bridge

PE09

speed control of dc motor by using


8051

PE10

speed control of dc motor using


four quadrant chopper

PE11

speed control of universal motor


using IGBT

PE12

speed control of induction motor


using voltage control

PE13

speed control of induction motor


using frequency control

PE14

Speed control of induction motor


using v/f control

PE15

H-Bridge and PWM based DC


Motor direction and speed control
system

PE16

Transformer less Variable


Frequency Drive

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

MOSFET bridge. Here sine wave PWM signals


are generated by controller and are given to
MOSFET bridge.

A cyclo converter converts an alternating current


(AC) waveform to another AC waveform of a
different frequency; In this project we are using 8
SCRs. This variable frequency is given to the
bulb where the flickering can be observed.
The controller will take the data from the key pad
and it will generate the PWM required for the
motor to rotate at desired speed. The pulses are
then given to the l293d which drives DC motor.
In this speed of the motor is controlled by four
quadrant operation of chopper .It consists of
MOSFET bridge where the pulses are varied to
get the required polarity and output of the output
voltage. This output is given to the DC motor.
In this input AC is converted to DC and type A
chopper is employed to get a variable DC output
voltage. This variable DC voltage is given to
universal motor where the speed of the motor is
varied.
Speed of induction motor is proportional to
voltage applied. Therefore input voltage is varied
using A.C voltage controller where firing pulses
of thyristors are varied according to desired
speed. In this only 2 SCR's which are in anti
parallel are used.
Speed of induction motor is proportional to input
frequency. Therefore input frequency is varied
using cyclo converter where firing pulses of
thyristors are varied according to desired speed.
In this both the input frequency & voltage is
varied so that the motor is driven at desired
speed. Here micro controller is used for
controlling action where firing pulses of
thyristors employed are varied according to
desired output speed.
In this speed of the motor is controlled by four
quadrant operation of chopper .It consists of
MOSFET bridge where the pulses are varied to
get the required output voltage.
Speed of induction motor is proportional to input
frequency. Therefore input frequency is varied by
using cyclo converter where firing pulses of
thyristors are varied according to desired speed.
Ph: 9985784340, 9396671541
Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

PS01

Substation monitoring system


(measurement of PF, voltage,
current, temp.)

PS02

Transmission line multiple fault


indication to substation

PS03

Automatic power factor correction


using switching capacitors

PS04

Automatic power factor correction


using static var compensators

PS05

Transformer oil temperature


monitoring with automatic Circuit
Breaker operation.

PS06

Design and construction of Earth


fault relay for single phase power
system

PS07
PS08

energy tapping identifier


Unbalanced three phase optimal
power flow for smart grids

PS09

Automatic change over for three


phase connection with data logger

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

Continuous monitoring of substation is essential


for reliable& safer power supply at customer
point. In this project are going to monitor various
supply parameters viz., voltage, frequency, p.f,
power ensuring protection against various faults.
Ensuring reliable supply to customers is major
point in distributing power. In this project
complete protection against such faults are
monitored & if any fault occurs it indicates to
nearby substation through RF technology
In this power factor correction unit it consists of a
number of capacitors that are switched by means
of relays. These contactors/relays are controlled
by a regulator that measures power factor in an
electrical network. Depending on the load and
power factor of the network, the power factor
controller will switch the necessary blocks of
capacitors in steps to make sure the power factor
stays above a selected value.
In this power factor correction unit consists of a
number of capacitors that are switched by means
of relays. These contactors are controlled by a
regulator that measures power factor in an
electrical network. Depending on the load and
power factor of the network, the power factor
controller will vary the firing angle of the
thyristor. This will vary the net value of the
capacitance connected to the supply.
The temperature of the transformer oil is
monitored and displayed on the LCD. When the
temperature increases we will switch ON cooling
FAN. Even after switching the FAN if the
temperature is not decreased then we will switch
of the transformer by using a relay. Bulb is
connected as a load.
We will measure the current in the earth
conductor by using current transformer and ADC.
When this current is increased to a value greater
than the pre defined value then the load is
switched off showing indication of the earth fault.
Buzzer is also activated by the controller.
Whenever a three phase load is unbalanced it will
correct the load by switching some of the single
phase loads to the other phases.
Whenever a three phase load is unbalanced it will
correct the load by switching some of the single
phase loads to the other phases and the status of
Ph: 9985784340, 9396671541
Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

PS10

PS11

PS12

PS13

PS14

PS15

PS16

SL01

SL02

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

all the loads is shown on the display.


In the distribution feeder if the single phase
consumer loads and unbalancing a three phase
system then the consumers are switched to other
phases so that the overall three phase system will
remain in balanced condition.
Single phasing preventer for
All the three phase induction motors need the
protection of three phase (3-ph)
power supply in all the three phases when it is
loads
running if any of the phases is having a power
outage then the motor is switched off by using
relay and the fault phase is displayed on the LCD
so that problem can be solved easily.
Microcontroller based Three Phase Whenever a three phase fault is occurred it will
Load safety implementation with
be indicated by using OP-AMPS and by
phase fault detector
measuring voltages and currents. And the type of
fault is indicated in the display.
An On-line Monitoring System of When there is a fault in the power supply the load
Transmission Line Conductor
is switched off by using a relay and the type of
fault i.e over voltage, under voltage and over
current is displayed on the LCD.
Over voltage or under voltage
Whenever there is fault in the transmission line
tripping mechanism
the load is switched off and the type of the fault is
displayed on the display. If the fault if temporary
fault then the load is reconnected to the line if not
the load remains disconnected. And the faulty
phase is also displayed on the display.
Three phase fault analysis with
Whenever there is fault in the transmission line
auto reset on temporary fault and
the load is switched off and the type of the fault is
permanent trip other wise
displayed on the display. If the fault if temporary
fault then the load is reconnected to the line if not
the load remains disconnected. And the faulty
phase is also displayed on the display.
Auto selection of any available
When a single phase load is connected to a phase
phase in 3 phase supply system
which is having a power outage then the load is
automatically switched to another phase by using
relays so that the availability of the single phase
from the three phases will be more.
Renewable Energy management Two modes of operation of the solar inverter will
Solar based lighting system with
be there. They are low power mode and balanced
inverter and CFL lamp load
power mode. In low power mode only one cfl
light is switched on and the backup time will be
more. In balanced power mode two cfl lights are
switched on for getting more brightness. Output
supply is taken from the inverter.
Solar pv cell tracking system for
The project aims at designing a system that would
obtaining maximum power output sense and follow the position of the sun and rotate
the panel in the direction of the sun to obtain
maximum power output
Automatic switching of consumer
connection in distribution feeder
for different load distribution

Ph: 9985784340, 9396671541


Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

SL03

Solar based irrigation pumping


system

SL04

Solar based LED street light


system with time controlled and
auto dimming based on ambient
light
Solar based traffic light control
system

SL05

SL06

AS01

AS02

Wireless motor starter with


acknowledgement using solar
energy for agricultural application
Smart Remote for controlling
electrical appliance through
android mobile.
Virtual nurse- controlling wheel
chair through android mobile

AS07

Smart Home/office automation


through android mobile.

AS09

Smart regulator for controlling fan


speed through Android mobile.
AC motor speed controller
through Android mobile.
Advanced street light controlling
system through smart phone.
Industry/home/office automation
through smart phone.

AS10
AS11
AS13

AS14

Industrial parameters monitoring


system through Smartphone

VP08

Home /office/industry electrical


appliances controlling by phone
call and confirmation through
voice feedback.

VP12

Substation monitoring and


controlling system with voice
alerts.

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

The solar energy form the pv panel is first stored


in the battery and then given to the inverter. The
ac output from the inverter is then connected to
the 230v operated motor and a pump is connected
to the motor for pumping the water.
This project is design to reduce the power with
present street light system.

Traffic Lights are controlled based on time and


power for these lights is obtained from Solar
panel.
This system is used to give information to
formers about power status and we can control
the motor without going to the field with SMS
With this we can control any electrical appliances
with our android phone, no need of another
remote .It is safe and secure also.
With this the patient can easily control his wheel
chair through simple and smart touching of
android mobile
With this we can control any electrical appliances
in home or office or industry with our android
phone, no need of another remote .It is safe and
secure also.
With this we can control speed of fan or AC from
our android mobile.
With this we can control speed of AC motor
from our android mobile
In this we can control street light from anywhere
through smart phone.
With this project we can control any electrical
appliances of office or home or industry from
anywhere by using Smart phone.
We can monitor different parameters like
temperature, voltage, etc through online using
smart phone from anywhere
In this we will switch off and switch on any
electrical appliances just by calling to this system
and press some buttons using DTMF technology.
This system also sends voice feedback of device
status that is whether device is on or off.
This system monitor the different parameters of
substation like voltage, current and temperature
and gives respective voice alerts when something
goes abnormal condition and takes necessary
action.

Ph: 9985784340, 9396671541


Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

FS01

FS05

Standalone data logger in


SD/MMC card with time stamp
for industrial applications.

In this we will monitor and store different


parameters in industry like temperature, voltage,
etc .We will store these parameters values in SD
card along with measured time and date also. The
stored data format will be in .txt file or excel
format so that we can go through entire monthly
data using system.
Advanced embedded system based As we know to save our world we have to reduce
a paperless feedback system for
usage of paper. This project helps in eliminate
colleges and event management
papers used in feedback systems. In this the
systems
feedback and suggestions should be entered from
key board and this data will be stored in memory
card in a file format using ARM7 micro
controller.

ET01

Industry parameters monitoring


and controlling system based on
embedded web server.

ET03

Zigbee and internet based


advanced street light controlling
system.

ET05

Internet based home/office


automation.

EE01

Wireless Scrutinizer for Detecting


the fault in Power System.

EE02

Wireless load measuring meter for


power line.

EE03

Up-to-date Recording System of


Power Line Losses.

EE04

Underground cable fault


identification.
.
Two quadrant chopper drive for
DC motor speed control.

EE05

EE06

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

Wireless motor starter with

In this we will monitor industry parameters like


current, voltage, temperature, etc through online
using internet from anywhere in the world and we
can also control electrical appliances from
internet.
With the help of internet and Zigbee technology
we can reduce man power in street light
controlling process. We can control street lights
from online itself.
With this system we can control any electrical
appliances of home or office from anywhere in
the world using internet.
We take a 230v supply voltage and measure the
current in it. Fault condition is created by using
bulbs. We measure the input and output current of
the load using 2 ct's. When the bulb is on we
assume fault is created and it is indicated in
another section using rf.
The power in the transmission line is calculated
by measuring voltage, current, power factor, and
this is indicated in the display by sending the data
wirelessly.
The power loss in the transmission line is
calculated by measuring the voltage drop in the
line. The voltage drop is created by using a
resistor and an inductor.
The objective of this project is to determine the
distance of underground cable fault from base
station in kilometers
This can be done for small dc motor as well for
big (around half hp) motors also depends upon
motor availability.
This system sends a message to user when power
Ph: 9985784340, 9396671541
Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

EE07

acknowledgement using solar


energy for agricultural application
Four quadrant chopper drive for
DC motor speed control

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

comes an also sends information whenever power


is absent. This system works with solar energy
This can be done for small dc motor as well for
big (around half hp) motors also depends upon
motor availability
the 230v ac is converted in to dc using SCRs and
the output voltage is measured by the ADC and
the firing angle of the SCRs is controlled by the
microcontroller only 2 SCRs and 2 diodes will be
there is converting circuit

EE08

design of closed loop controlled


DC voltage regulator using full
wave semi- converter

EE09

Automatic power factor correction


using switching capacitors.

EE10

Automatic power factor correction


using static VAR compensators.

EE11

Design of closed loop controlled


DC voltage regulator using full
wave converter.

EE12

Three phase load protector with


automatic fault indication using
micro processor.

EE13

Thyristor based soft starter.

EE14

Thyristor based star/delta starter.

EE15

Unbalanced Three-phase Optimal


Power Flow for Smart Grids.

EE16

Maximum Demand Controller for


Industries.

EE17

Automatic Switching of consumer


connection in distribution feeder
for efficient load distribution

The power factor is measured by using zero


crossing detectors and it is corrected by
connecting the capacitors using TRIACs or
relays.
The power factor is measured by using zero
crossing detectors and it is corrected by
connecting a single capacitor of larger value
using TRIAC and by controlling the firing angle.
The 230v ac is converted in to dc using SCRs and
the output voltage is measured by the ADC and
the firing angle of the SCRs is controlled by the
microcontroller only 4 SCRs will be there in
converting circuit.
Whenever a three phase fault is occurred it will
be indicated by using OP-AMPS and by
measuring voltages and currents. And the type of
fault is indicated in the display.
The advantage of these starters is the starting
current can be controlled to a much lower values
than that of the value achieved with the
traditional starters.
6 bulbs are used to represent the motor. There are
connected to form into 3 pairs with 2 each
connected in series. They are connected in star
first then in delta to the three phase supply.
Whenever a three phase load is unbalanced it will
correct the load by switching some of the single
phase loads to the other phases.
This system automatically switches off the low
priority appliances whenever maximum load
power reached.
Whenever a three phase load is unbalanced it will
correct the load by switching some of the single
phase loads to the other phases.

EE18

Distribution grid transformers

The data at the distribution transformer is


Ph: 9985784340, 9396671541
Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

EE19

EE20

EE21
EE22

EE23

EE24

EE25

monitoring using GSM with


forced cooling control system

observed using GSM and if there is any fault it


will on the cooling fans. If the fault is on current
then it will switch off the transformer

Remote substation monitoring


system using bidirectional power
line communication.
Design of closed loop controlled
DC voltage regulator using full
wave converter through computer.

With the same 230 v power line we can monitor


substation parameters.

Design of closed loop controlled


ac voltage regulator using TRIAC.
Transmission line multiple faults
detection and indication to
electricity board.
Power theft identification system
in distribution lines using
differential power measurement.
Automatic transformer shunt and
series parameter calculation from
open circuit and short circuit test
reading.
Closed loop dc motor speed
control.

EE26

Design of cyclo converter using


micro controller.

EE27

Reverse power protection for


generator.

EE28

Automatic transformer protection


using numerical relay.
Automatic phase sequence
corrector.
Design of earth fault relay.

EE29
EE30

EE31

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

Reactive power compensation


using STACOM.

the 230v ac is converted in to dc using SCR's and


the output voltage is measured by the ADC and
the firing angle of the SCRs is controlled by the
microcontroller only 2 SCRs and 2 diodes will be
there is converting circuit. The required output
voltage is set by using hyper terminal.
Same as the speed control of ac motor but here
output voltage is measured using ADC.
Voltage and current faults are detected using
differential protection scheme and the type of the
fault is transmitted using RF.
Current at both the ends of transmission line are
measured using CTs and if there is a difference in
those currents it means power was theft.
The OC and SC test readings of the transformer
are given through keypad and microcontroller
will do calculation and give the output on the
LCD.
In this we will control the speed of dc motor and
we also take the feedback from the motor and
correct the speed level to desired level.
The input supply frequency is about 50 Hz. We
can get the multiples of 50hz using the SCRs.
controller will generate pulses for 4 SCRs and the
output frequency of the sine wave is controlled.
The phase angle of the current and voltage are
measured to measure whether the power is in
reverse direction of not if the power is in reverse
direction then it will switch of the supply.
Difference in currents of the two current
transformers' will give a buzzer sound.
Whenever the RYB phase sequence is changed it
will be corrected by using relays.
Whenever there is an internal fault or the earth
fault then we can sense that by measuring the
magnitude of the current and this will give type of
the fault.
The power factor is measured by using zero
crossing detectors and it is corrected by
connecting a single capacitor of larger value
Ph: 9985784340, 9396671541
Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

EE32

EE33

EE34

EE35

EE36

EE37

EE38

EE39

EE40

EE41

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

using TRIAC and by controlling the firing angle.


This will be same as the speed control of the ac
motor using TRIAC but only difference is IGBT
is used to vary the voltage and we will control the
dc voltage. First we will convert the 230v ac into
dc and then we will control.
Efficient power saver for street
This project saves more power that is being
lights using LDR, RTC, LEDs
wasted in present street light switching. In this we
light with solar power
will consider time and sunlight intensity and we
use LED lights and solar power
Agricultural motor controlling
The former can control his field motor without
with motor safety and water level
need of going to his field just by sending
indicator using GSM.
message. This system also provides safety motor
from over heat, low phase power and water level
indication.
Automatic changeover for 3
Whenever a three phase load is unbalanced it will
phases connections with data
correct the load by switching some of the single
logger.
phase loads to the other phases.
Solar Tracking system for
In this the panel will give maximum power by
Maximum power output with real changing its direction according to sun light
time power monitoring system.
direction.
It can be done with two motors arrangement or
single motor arrangement
Voice guider and medicine
In this the user will be given one remote (IR or
reminder for patients and old age
RF or ZIGBEE), he has to press any button to get
persons.
what service he wants and that is played from
voice IC so that any person can hear it and come
to the user. Another feature of this project is to
remind the user for medicines.
Broken conductor detection for
The broken conductor can be sensed by using the
overhead lines.
voltage drop in the line. We will give three
switches to indicate broken condition when the
switch is operated it will indicate which switch is
operated in terms of kilometers.
Intelligent shopping trolley using
With this we can save billing time and
RFID
instantaneously the rate and expiry date of the
product will be displayed so that we can do the
shopping within our budget.
Elegant home with power saving,
In this we will provide multi features to home like
security, safety, remote controlling remote controlling of home appliances ,auto
and auto control of water tank
controlling of lights depends upon sunlight and
motor
auto controlling of water tank motor when tank is
full and alert the user when intruders come or
when gas leakage or fire accident occurs
Intelligent train engine to avoid In this we will control the train by monitoring the
accidents and controlling railway drivers position or activeness and the gate will b
gate automatically
e controlled automatically when train is near the
gate.
Speed control of universal motor
using IGBT.

Ph: 9985784340, 9396671541


Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

EE42

EE43

EE44

EE45
EE46

EE47

EE48

EE49

EE50
EE51

EE52
EE53

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

Design And Development Of In this we have one smart card which contains
Prepaid Energy Meter With Serial number units depends upon the amount we will
Data Transmission
pay. These units will be given to energy meter
system to activate and it will supply power to
home till that units are consumed and we have
recharge same card again.
Protection And Control Of Low
The motor will be protected from over voltage,
Voltage Motors Used In Industrial current, temperature and ground fault conditions.
Applications.
This system immediately switches off the motor
whenever abnormal condition occurs and intimate
to control room through RF communication.
Flexible load sharing of
It continuously measure the load current
transformer with GSM SMS
and it shares this load with another
transformer when the load is more and
send an alert through message. The user
can also share directly whenever he wants
just by sending message
Agriculture field motor control
Motors in the field are controlled with the help of
system using GSM
predefined SMS.
Industrial Electrical Devices
By this project, we can control the devices in the
Control System
industries by sending predefined SMS to the
controlling unit.
GSM based DC Motor Speed
The speed and direction of DC motor can be
and Direction Control
controlled by sending predefined SMS to the
system
Cell Phone based Street Light The on and off controls of the street lights can be
Controlling System with light done using GSM technology. If any light does not
failure indication system.
work then that information is sent as message to
electricity department.
Temperature Measurement
Temperature sensor is used to measure the
over GSM Mobile
temperature in a particular room and this
measured value is sent through GSM to the user
mobile.
Password protected GSM based
Controlling the devices from remote places only
Device control.
by authorized persons.
Fingerprint based Access Control
Security is provided in restricted areas using
system
fingerprint technology. The persons are asked to
give their fingerprint and the system compares
this fingerprint with the already stored
information in the system and only allows into if
it is an authorized one.
Finger print based elevator (lift)
Only authorized persons are allowed to access the
operating system.
lift controls.
Low Cost Wireless Sensor
The motor will be protected from over voltage,
Network In Field Operation
current, temperature and ground fault conditions.
Monitoring Of AC Motor.
This system immediately switches off the motor
whenever abnormal condition occurs and intimate
to control room through RF communication.
Ph: 9985784340, 9396671541
Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

EE54

A Zigbee Smart Energy Meter


Implementation For Energy
Efficient Buildings.

In This system one control system collects the


data from different meters in the building and we
can control the appliances of each floor through
this control system.

EE55

Development of a smart power


meter for AMI based Zigbee
communication Advanced
Metering Infrastructure (AMI).

This will be useful in heavy apartments


.individual meters data will be collected and
maintained by main system .this main system
sends collated data to electricity board.

EE56

Remote Power On/Off Control


And Current Measurement For
Home Electric Outlets Based On
A Low-Power Embedded Board
And Zigbee Communication
Remote-Controllable and EnergySaving Room Architecture Based
on Zigbee Communication.

We can control the home appliances through


Zigbee remote and this system will display the
power consumed by the loads.

EE57

In this we can control the loads through Zigbee


remote or they will also be controlled
automatically to save the power.
Industrial devices are monitored and controlled
using Zigbee Technology.

EE58

Applications of Short Range


Technologies to Industrial
Automation: A Zigbee Approach.

EE59

System for Measuring Power


Parameters with Zigbee
Connectivity.

This system measures the power from each home


and sends to central system which is useful in
apartments.

EE60

Wireless Data Encryption and


Decryption Using ZigBee

Which used in security applications

EE61

ZigBee Based Automated


Irrigation System.

Using ZigBee this system controls the irrigation


system automatically.

EE62

EE63

EE64

EE65

EE66

We can control this robot through Bluetooth from


PC and the video sent by robot can be seen in TV
Bluetooth Robot with CMOS or PC
image sensor(SPY ROBOT)
Remote
controlled
home With this we can control home appliances like
lights, fan, motor, etc through Bluetooth. This is
automation using Bluetooth
safe and secured.
Bluetooth based industrial data This project measures different parameters in
industry like voltage, current and temperature and
acquisition system
transmit this data to PC continuously through
Bluetooth.
Industrial devices controlling With this we can control industry appliances like
machines and motors through Bluetooth. This is
system using Bluetooth
safe and secured.
Intelligent
electricity
billing This system receives the units consumed from
various meters and generates the bill accordingly.
system using Bluetooth
This saves the cost, time and manpower.
Ph: 9985784340, 9396671541
Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

EE67

Touch screen based smart home


automation

EE68

Electrical parameters data logger

EE69

EE70

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

We can control the home appliance just by smart


touch

In this we will continuously measure and display


electrical parameters like voltage, current,
frequency and temperature
Smart horn for vehicles with This system reduces the sound pollution that is
generated by unnecessary use of horn. This
alcohol detection for drivers
controls the horn intensity depends upon vehicle
distance and also gives the special sound when
object is detected at back side if vehicle moves
backside and this system only allows for driving
if driver does not consume alcohol
Smart blind stick with ultra sonic This stick gives different sound intensity depends
upon the object distance from person or we can
sensor.
play some voice also depends upon distance.

EE71

PIR sensor based power saver for This project is used to save the power in
conference halls and in auditoriums. When there
auditorium and conference halls.
are no persons in the hall ,then lights and fans
will be switched off automatically

EE72

Intelligent security and safety This project detects fire accidents, gas leakages
system for colleges and industries and also alert through SMS when main door is
closed without closing any other room entrance or
if any other door is opened without opening main
door

EE73

An Efficient Monitoring Of
Substations Using Microcontroller
using RF
Wireless Power Grid Controller

EE74
EE75
EE76

RF based industrial Automation


System
DC motor speed and direction
control using RF

EE77

Wireless Stepper motor control


using RF

EE78

Power Management System in


Hotels using PC.
PC based Hi-tech Home
Implementation.
Industrial Automation using
PC.

EE79
EE80

This system monitors the subsystem to provide


safety and intimate to control room through RF
With this we can control the power grid through
PC using RF communication
The industrial loads like motors, coolers, etc are
monitored and controlled by a RF remote.
In this project we can control speed and direction
of DC motor depending on the requirement using
RF signals
The stepper motor direction can be controlled
using RF communication.
The various appliances in the hotels are
controlled by giving commands from the PC.
We can control the home appliances just by
sitting in front of PC.
The industrial appliances are controlled by the
commands issued from the PC. The controlling
unit receives these commands from the PC and
Ph: 9985784340, 9396671541
Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

EE81

Industrial electrical appliances


control using IR.

EE82

DC motor speed and direction


control using IR.

EE83

Stepper motor control using IR

EE84

Automatic Room light controller


with visitor counter using IR.

EE85

Auditorium Controlling System

EE86

Shopping Malls Security and


Power Management System
using IR

EE87

AC motor speed control using


TRIAC
Phase Sequence Indicator and
Controlling System.

EE88

EE89

Boiler Monitoring and Control


System.

EE90

Involuntary Industrial Power


Scheduler using Embedded
System.
Power Saver for Advertisement
Hoardings using RTC.

EE91

EE92

Solar Tracker for acquiring


maximum power.

EE93

Water Scheduling for


Municipalities

EE94

Electronic Security System


for Homes/Industries with
auto dialer.

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

controls the devices according to the commands.


To reduce the manpower for controlling the
devices we are implementing this project. Here
we will be controlling devices by using a general
TV REMOTE.
A DC motor is controlled using wireless
communication. In this project we can control the
speed of the dc motor and its direction.
The direction of the stepper motor can be
controlled using an IR remote.
This project displays the number of persons
present in the room and controls the light
according to the intensity of daylight.
The lights and fans in auditorium are controlled
by IR remote.
The design of security and the method of
consuming the power in the shopping malls are
carried out in this project.
The speed of AC motor can be varied rapidly on
and off by TRIAC.
The controlling unit continuously whether 3phase is coming from the line or not so as to run
the motors which run only with 3-phase. If 3phase is not coming, the controlling unit
automatically shuts down the system.
The temperature is measured and controlled for
the industrial boilers.
The power management in the industries can be
done effectively using this project.
This system switches on the lights only at
preprogrammed timings using RTC thus saving
the power up to the maximum extent.
The project aims at designing a system that would
sense and follow the position of the sun and rotate
the panel in the direction of the sun to obtain
maximum power output.
Water supply to different localities is done on
time basis. The supply will be automatically cut
once the time allotted to that particular locality
lapses.
This system provides security to the homes or
offices by interfacing sensors with the controlling
units. If anything goes wrong, the system
automatically dials up to the predefined number
and also activates the alert system.
Ph: 9985784340, 9396671541
Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

EE95

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

Energy Saver for Automatic Room The system aims at saving the power by
Light Controller with Visitor
switching on/off the light depending upon the
Counter
sensor output. It also counts the number of
persons present in the hall and displays this value
on the LCD.

SOME EXAMPLE KIT PICTURES FROM EES TECH CENTER

Ph: 9985784340, 9396671541


Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

Ph: 9985784340, 9396671541


Email: info@eestechcenter.com
Www. eestechcenter.com

EL E G A N T
EMBEDDED SOLUTIONS

# 202, Padmasagar Aprts,


Near Community Hall,
SR Nagar, Hyderabad - 500 038.

Ph: 9985784340, 9396671541


Email: info@eestechcenter.com
Www. eestechcenter.com

You might also like