- INTERRATCSTHD2FECN0
Threshold to stop inter-RAT measurement with measurement quantity of Ec/No for CS
domain services
Value range: -24~0
Physical unit: dB
Content: For CS domain services, when Ec/No is used as the measurement quantity for interRAT measurement, the RNC sends the signaling to deactivate compressed mode and stop
inter-RAT measurement, if the UE reports the event 2F when the measured value is larger
than the value of this parameter.
Recommended value (default value): -12
- INTERRATCSTHD2DRSCP
Threshold to trigger inter-RAT measurement with measurement quantity of RSCP for CS
domain services
Value range: -115~-25
Physical unit: dBm
Content: For CS domain services, when RSCP is used as the measurement quantity for interRAT measurement, the RNC sends the signaling to activate compressed mode and start
inter-RAT measurement, if the UE reports the event 2D when the measured value is smaller
than the value of this parameter.
Recommended value (default value): -100
- INTERRATCSTHD2FRSCP
Threshold to stop inter-RAT measurement with measurement quantity of RSCP for CS domain
services
Value range: -115~-25
Physical unit: dBm
Content: For CS domain services, when RSCP is used as the measurement quantity for interRAT measurement, the RNC sends the signaling to deactivate compressed mode and stop
inter-RAT measurement, if the UE reports the event 2F when the measured value is larger
than the value of this parameter.
Recommended value (default value): -97
- INTERRATHTHD2DECN0
Threshold to trigger inter-RAT measurement with measurement quantity of Ec/No for PS
domain HSPA services
Value range: -24~0
Physical unit: dB
Content: For PS domain HSPA services, when Ec/No is used as the measurement quantity for
inter-RAT measurement, the RNC sends the signaling to activate compressed mode and start
inter-RAT measurement, if the UE reports the event 2D when the measured value is smaller
than the value of this parameter.
Recommended value (default value): -15
- INTERRATR99PSTHD2DECN0
Threshold to trigger inter-RAT measurement with measurement quantity of Ec/No for PS
domain R99 services
Value range: -24~0
Physical unit: dB
Content: For PS domain R99 services, when Ec/No is used as the measurement quantity for
inter-RAT measurement, the RNC sends the signaling to activate compressed mode and start
inter-RAT measurement, if the UE reports the event 2D when the measured value is smaller
than the value of this parameter.
Recommended value (default value): -15
- INTERRATHTHD2FECN0
Threshold to stop inter-RAT measurement with measurement quantity of Ec/No for PS
domain HSPA services
Value range: -24~0
Physical unit: dB
Content: For PS domain HSPA services, when Ec/No is used as the measurement quantity for
inter-RAT measurement, the RNC sends the signaling to deactivate compressed mode and
stop inter-RAT measurement, if the UE reports the event 2F when the measured value is
larger than the value of this parameter.
Recommended value (default value): -13
- INTERRATR99PSTHD2FECN0
Threshold to stop inter-RAT measurement with measurement quantity of Ec/No for PS
domain R99 services
Value range: -24~0
Physical unit: dB
Content: For PS domain R99 services, when Ec/No is used as the measurement quantity for
inter-RAT measurement, the RNC sends the signaling to deactivate compressed mode and
stop inter-RAT measurement, if the UE reports the event 2F when the measured value is
larger than the value of this parameter.
Recommended value (default value): -13
- INTERRATHTHD2DRSCP
Threshold to trigger inter-RAT measurement with measurement quantity of RSCP for PS
domain HSPA services
Value range: -115~-25
Physical unit: dBm
Content: For PS domain HSPA services, when RSCP is used as the measurement quantity for
inter-RAT measurement, the RNC sends the signaling to activate compressed mode and start
inter-RAT measurement, if the UE reports the event 2D when the measured value is smaller
than the value of this parameter.
Recommended value (default value): -110
- INTERRATR99PSTHD2DRSCP
Threshold to trigger inter-RAT measurement with measurement quantity of RSCP for PS
domain R99 services
Value range: -115~-25
Physical unit: dBm
Content: For PS domain R99 services, when RSCP is used as the measurement quantity for
inter-RAT measurement, the RNC sends the signaling to activate compressed mode and start
inter-RAT measurement, if the UE reports the event 2D when the measured value is smaller
than the value of this parameter.
Recommended value (default value): -110
- INTERRATHTHD2FRSCP
Threshold to stop inter-RAT measurement with measurement quantity of RSCP for PS domain
HSPA services
Value range: -115~-25
Physical unit: dBm
Content: For PS domain HSPA services, when RSCP is used as the measurement quantity for
inter-RAT measurement, the RNC sends the signaling to deactivate compressed mode and
stop inter-RAT measurement, if the UE reports the event 2F when the measured value is
larger than the value of this parameter.
Recommended value (default value): -107
- INTERRATR99PSTHD2FRSCP
Threshold to stop inter-RAT measurement with measurement quantity of RSCP for PS domain
R99 services
Value range: -115~-25
Physical unit: dBm
Content: For PS domain R99 services, when RSCP is used as the measurement quantity for
inter-RAT measurement, the RNC sends the signaling to deactivate compressed mode and
stop inter-RAT measurement, if the UE reports the event 2F when the measured value is
larger than the value of this parameter.
Recommended value (default value): -107
Thanks for reading Call Drop Rate improvement by Parameter change in 3G UMTS/WCDMA
Huawei, hope can help you best network.
You might also Need to know:
- Drop Call Rate Optimization step in GSM and UMTS
- WCDMA CSSR Optimization tips
- Trial Power Control in GSM Huawei for Quality Improvement
- How to optimize Handover Success Rate(HOSR) in GSM Network