CONTRACTOR
KANDHKOT FIELD GAS COMPRESSION STATION (KFGCS) PROJECT
Document Title:
Date:
Rev: 0
Class: II
Sheet 1 of 3
26/10/2007
ARS/ SB
SN
ShS
LiuXG
11/9/2007
ARS/ SB
SN
ShS
LiuXG
Rev
Description
Date
Prepared
Checked
Approved
CPECC
Owner
OWNER
CONTRACTOR
KANDHKOT FIELD GAS COMPRESSION STATION (KFGCS) PROJECT
Document Title:
Rev: 0
GENERAL-
Equipment Number:
ET-01
P.O. Number:
TBA
Specification Requirements:
SP-00-E-0011
Vendor:
Manufacturer:
Model Number:
Serial Number:
Class: II
Sheet 2 of 3
9
10
ENVIRONMENTAL DATA-
11
Maximum Temperature:
53 0C
Area Classification:
Hazardous
Non-Hazardous
12
Minimum Temperature:
06 0C
Zone:
13
06/ 53 0C
Group:
IIB
IIC
14
Maximum Humidity:
57.5 %
15
Design Humidity:
16
58
17
Transformer Location:
18
19
ELECTRICAL CHARACTERISTICS-
IIA
Temperature Class:
Indoor
85
IP 55
20
21
Primary Voltage:
11 kV
22
Secondary Voltage:
0.415
kV
Tapping Range :
+/- 5%
Tapping Step :
24
Frequency:
50
Hz
Insulation Class:
Class A
Temperature Rise :
25
Number of Phases:
Phase
Cooling Method
26
Vector Group:
Dyn 11
27
System Earthing:
Directly Earthed
2000 KVA
75 kV
On Load
Tap Changer:
Required
28
Rated BIL:
30
Required
Not Required
31
Required
Not Required
32
Required
Not Required
33
Required
Not Required
34
Required
Not Required
35
Required
Not Required
36
Required
Not Required
37
Buchholz Relay
Required
Not Required
38
TRANSFORMER ARRANGEMENT-
39
Sealed
Conservator
Dry Type
40
Mounting Arrangement:
Pad Mount
Pole Mount
Other
41
42
CABLE DETAILS
43
TBA
mm 2
XLPE/SWA/PVC
mm OD
TBA
mm 2
XLPE/SWA/PVC
mm OD
45
46
OTHER-
47
Tropicalisation:
Required
Not Required
48
Protective Coating:
Standard
Other
49
Neutral CT:
Required
Not Required
50
Required
Not Required
51
GENERAL NOTES:
1. Fifteen (15) days notification to be given prior to testing.
2. TBA To Be Advised
Off Circuit
2.5%
Class A
ONAN
Conservator:
29
44
dBA
Outdoor
Not Required
OWNER
CONTRACTOR
KANDHKOT FIELD GAS COMPRESSION STATION (KFGCS) PROJECT
Document Title:
Rev: 0
GENERAL-
Equipment Number:
ET-01
P.O. Number:
TBA
Specification Requirements:
SP-00-E-0011
Vendor:
Manufacturer:
Model Number:
Serial Number:
Class: II
Sheet 3 of 3
9
10
ELECTRICAL CHARACTERISTICS-
11
kVA
50% load
Efficiency at 75oC:
75% load
13
14
kW
15
16
100% load
12
kW
0.8 PF
1.0 PF
%
17
18
19
A
o
20
21
Voltage:
22
Voltage Source:
23
Quantity
24
Pumps
25
Fans
Make
Model
Power
Pressure
Make
Model
Range
26
27
MEASUREMENT-
ACCESSORIESMake
28
Model
Quantity
Range
Gas Pressure Relief Outlet:
29
30
Buchholz Relay:
31
Winding Temperature:
32
33
34
35
Bushings:
36
Surge Divertors:
37
38
39
40
41
42
43
Sides:
mm
Overall Dimensions:
Bottom:
mm
44
45
mm
46
47
48
49
GENERAL NOTES:
1. All the above information shall be provided by the Vendor.
kg
kg
Oil Required:
Litres
Litres
Depth, mm