You are on page 1of 88

Price list

valid until 30.06.2015

Modernization
Energy efficiency for living and industry

Warm air production

Heat plants

Dehumidifiers

Experience
and expertise
Kroll Energy GmbH offers you
longtime experience and expertise.
We are specialists for heating,
ventilation and LED lighting for
industry and municipalities.
We offer you well-engineered
solutions for your needs and
professional advice.
Profit from the advantages
coming from our expertise!
As a medium-sized company,
we profit from five decades of
experience.
We have got satisfied
customers all over the world.
Trust in our knowledge, too!

A manifold product range


for every need:
Permanently
condensing boilers
Mobile and stationary
warm air heaters
Mobile oil-, gas- and
electric heaters
Mobile heating
plants hot water
Mobile heating
plants warm air
Universal oil burners
Dehumidifiers
Warm air heaters gas

We are looking forward to your


inquiries!

Kroll GmbH
Wrme- und Lftungstechnik
Pfarrgartenstrae 46
D 71737 Kirchberg / Murr
phone +49 7144 830 -200
fax
+49 7144 830 -201
e-mail vertrieb@kroll.de
web
www.kroll.de

CONTENTS
page

Services

Permanently condensing boilers

BK50 / BK70

10

Permanently condensing boilers

BK100 / BK250

11

BK scope of delivery

BK20 BK250

12

BK accessories
BK hydraulic systems

13 23
24 26

Multi-Fuel oil burner

KG-UB

27

Accessories

30

Multi-Fuel oil heater

W401K

31

Air heaters

LH

33

Air heaters accessories

LH

36 37

Stationary warm air heaters oil/gas

38

Accessories

46 48

DV

49

Warm air heaters gas

NB2 NB11

50

Accessories

NB2 NB11

51 52

Mobile heat plant (warm air)

HM

54

Accessories

HM

57

BKM

58

Boilers / Multi-Fuel oil burner

Boilers/Multi-Fuel oil burner

Warm air heaters stationary


Warm air heaters stationary

Ceiling fan

Mobile warm air heaters/ Mobile heat plant

Concrete silo

SH

60

Mobile warm air heaters oil/gas

62

Accessories

66 67

Mobile oil-fired heaters + Accessories

MA

68

Infrared oil heater

IR45

69

P/PX/PE

70 73

74 76

TK/TE

77 80

Conditions of sales and delivery

82 83

Gas-fired heaters
Electric heaters

Mobile warm air heaters /


Mobile heat plant

Mobile heat plant (warm water)

Dehumidifiers

This price list supersedes all previous price lists!

Dehumidifying

Dehumidifying

Services

Boilers / Multi-Fuel oil burner

Permanently condensing boilers BK20BK250


Commissioning and operating instructions

BK50 BK100
BK250

260,
520,

Mounting help

BK20 BK100
BK250

455,
650,

Commissioning and operating instructions gas

BK50 BK100
BK250

390,
650,

Commissioning and operating instructions for boiler cascades

on request!

Optimization of facilities (only if RC7000 module is installed)

Charging on a time and material basis


(75, /h) plus travel expenses

Optimization of facilities without RC7000

Charging on a time and material basis


(75,- /h) plus travel expenses
plus 100, for RC7000

Lump sum for maintenance/cleaning *


including measuring lump sum and travel expenses

BK50 BK100
BK250

395,
500,

Travel expenses (there and back) 0,75 per kilometre


For the initial commissioning/training, a professional of the installing company needs to be on site.
* Lump sum for maintenance/cleaning plus wear and spare parts / Outside Germany plus travel expenses according to effort.

Warm air heaters stationary

Lump sum for maintenance/cleaning *


including measuring lump sum and travel expenses

25S 110S
140S 360S
430S 790S
25H 70H
25SL 70SL
N2 N4
N5 N11
NB2 NB11

295,
410,
495,
295,
295,
245,
295,
295,

M25 M50
M25K MK70
M70 M200

245,
245,
295,

Mobile warm air heaters


Lump sum for maintenance/cleaning *
including measuring lump sum and travel expenses

* Lump sum for maintenance/cleaning plus wear and spare parts / Outside Germany plus travel expenses according to effort.
The lump sum for maintenance does not apply for units with installed multi-fuel oil burner!

Services
Mobile heat plant hot water
BKM120

430,

HM100 HM200

410,

Boilers / Multi-Fuel oil burner

Lump sum for maintenance/cleaning *


including measuring lump sum and travel expenses

Mobile heat plant warm air


Lump sum for maintenance/cleaning *
including measuring lump sum and travel expenses

Mobile heat plant concrete silo


Lump sum for maintenance/cleaning *
including measuring lump sum and travel expenses

on request!

* Lump sum for maintenance/cleaning plus wear and spare parts / Outside Germany plus travel expenses according to effort.

Trainings
Sales training at Krolls premises per day/participant

105,

Technical training at Krolls premises per day/participant

105,

Training on site per day/participant

105,

Travel expenses will be charged according to time and effort.

Boilers / Multi-Fuel oil burner

Permanently
condensing boilers
The models BK50 to BK250
certified, convincing power!

BK50 / BK70

BK100

BK250
Delivered unit may differ from the picture.

Permanently
condensing boilers
Boilers / Multi-Fuel oil burner

System advantages compared to other oil-fired


condensing boilers
Due to the boilers construction, the flue gas is cooled down to about 60C 80C
already inside the boiler body where it transfers the major part of its heat to the boiler
water, before it enters the plastic heat exchanger.
Permanent condensation, completely independent from the return temperatures
(see comparison).
The boiler body stays dry due to the integrated return temperature lifting. This has got
a positive effect on cleaning the boiler, as the residues can be removed very easily and
quickly.
The heat exchanger where the condensation takes place is made of TUV-approved
plastic and thus resistant against acid sulphur (sulphur dioxide + water).
Therefore, no sulphur-free heating oil is needed.
Furthermore, the heat transfer is exclusively done in a counterflow with air/flue gas.
So there is no pollution nor blocking. Due to the permanent condensation, the
secondary heat exchanger virtually cleans itself. There is no rusting through with our
KROLL system.
Due to the permanent condensation, the heat exchanger practically cleans itself.
Should the plastic heat exchanger be polluted due to wrong or bad burner settings,
it can be cleaned very easily with water.
The flue gas is washed out due to the permanent condensation.
The environmentally harmful acid sulphur is neutralized in the neutralization box
and is lead into the canalization, now pH-free. So, only water steam is emitted into the
atmosphere, no sulphur dioxide.
This is a very positive effect on the environment!
Due to the integrated modulating flue gas fan, the combustion chamber pressure
is adapted to the weather c
onditions. This gives constant combustion conditions,
independent from draught or pressure in the chimney.
Characteristics:
with burner for operation with heating oil or natural gas
weather-controlled comfort control
neutralization box
two-stage burner
distance control via internet
operation with standard heating oil, bio oil or heating oil with little sulphur possible
Comparison of the flue gas losses

Comparison of the energy saving

Old boiler, 15 20 years


Modern low-temperature boiler

Partially condensing boiler


Kroll BK

Comparison of the flue gas temperatures

All indications without engagement!

Permanently
condensing boilers
Boilers / Multi-Fuel oil burner

Functional scheme BK50/BK70/BK100


Security flow
Boiler body with heat
recovery surfaces

Self-optimizing control

Heating flow
Four-way mixer with servomotor
Heating return

Boiler circuit pump


Fan burner
Flue gas passes,
washed by the boiler water
Connection for expansion
vessel and KFE cock
Flue gas fan

Refeed of
the residual heat
~ 50 60 C

Condensate drain

Heat exchanger for recovery


of the residual heat

Neutralization box
with natural granulate
(no disposal required)

Functional scheme BK250


Boiler body with heat
recovery surfaces

Safety flow

Heating flow (4-way mixer)

Heating return (4-way mixer)


(Boiler circuit pump not shown!)

Flue gas collector box


Fan burner
Flue gas passes,
washed by the boiler water

Modulating flue gas fan

Refeed of
the residual heat
ca. 50 60 C

Combustion air inlet

Heat exchanger for recovery


of the residual heat

Condensate
water drain

Neutralization box
with natural granulate
(no disposal required)

Permanently
condensing boilers
Operating mode of the permanently condensing boilers
Here, it transfers the major part of the sensible heat to the boiler water.
The water is heated up from at least 55C to maximum 80C, going upwards in a counterflow.
After that, the flue gas enters the secondary heat exchanger made of PP plastic where first
more of the sensible heat and then, after reaching the dew point temperature, the latent
heat is used to heat up the fresh air, taken in for the burner, to up to 60C.
The flue gas leaves the system with less than 48C (for heating oil) and enters the chimney
via the plastic flue gas pipe. There, it cools down to about 20C to 40C at the end of the
chimney, using the air that comes in from the outside and then goes to the plastic heat
exchanger and finally to the burner.
The air which is taken in from the outside is already preheated inside the chimney to
about 30C.

Boilers / Multi-Fuel oil burner

The flue gas being created at a flame temperature of about 1200C is cooled down
to about 70C by the flue gas passes which are surrounded by the boiler water.

Permanently
condensing boilers
Boilers / Multi-Fuel oil burner

Model

BK70

kW

33 49

50 70

Unit with oil burner Giersch

kW

2-stage
33 49

2-stage
50 70

Boiler completely assembled

No.

8.814,
S05641

10.082,
S04804

Boiler partially assembled

No.

Unit with oil burner Weishaupt

kW

33 40

44 49

2-stage
50 70

Boiler completely assembled

No.

9.071,
S04212

9.071,
S04214

10.898,
S04215

Boiler partially assembled

No.

Unit with gas burner Weishaupt

kW

2-stage
44 49

2-stage
50 70

Boiler completely assembled

No.

9.277,
S04368

11.395,
S04371

Boiler partially assembled

No.

Power range

BK50

Dimensions completely assembled with burner

10.082,
S04805

10.898,
S04227

11.395,
S04372

Dimensions without casing

Dimensions of the largest element as delivered

BK50

BK70

Length

mm

1548 1

1233 2

1111 3

1548 1

1233 2

1111 3

Width

mm

645 1

632 2

585 3

645 1

632 2

585 3

Height

mm

1474 1

1474 2

1069 3

1474 1

1474 2

1069 3

Weight

kg

482 1

384 2

271 3

482 1

384 2

271 3

LAS connection *
Flow/return

DN80/125

DN80/125

DN32 (1 1/4") / AG

DN32 (1 1/4") / AG

* Boiler connection piece not included in delivery! LAS = air/flue gas system

10

Permanently
condensing boilers
Model

BK100

BK250

kW

71 120

150 250

Unit with oil burner Giersch

kW

2-stage
71 120

2-stage
150 250

Boiler completely assembled

No.

12.268,
S04806

Boiler partially assembled

No.

12.268,
S04807

Unit with gas burner Giersch

kW

2-stage
150 250

Boiler partially assembled

No.

27.197,
S04865

Unit with oil burner Weishaupt

kW

2-stage
71 120

Boiler completely assembled

No.

13.008,
S04216

Boiler partially assembled

No.

13.008,
S04229

30.672,
S05599

Unit with gas burner Weishaupt

kW

2-stage
71 120

2-stage
150 250

Boiler completely assembled

No.

14.257,
S04378

Boiler partially assembled

No.

14.257,
S04380

26.757,
S04864

2-stage
150 250

30.736,
S05598

BK250

BK100

Dimensions completely assembled with burner

Boilers / Multi-Fuel oil burner

Power range

Dimensions without casing

Dimensions of the largest element as delivered

BK100

BK250

Length

mm

1738 1

1458 2

1305 3

1807 1

1770 2

1551 3

Width

mm

850 1

842 2

777 3

1171 1

780 2

780 3

Height

mm

1632 1

1632 2

1122 3

1991 1

1973 2

1321 3

Weight

kg

759 1

628 2

440 3

1392 1

1181 2

672 3

LAS connection*
Flow/return

DN110/160

DN160 (only flue gas pipe)

DN50 (2") / AG

DN80 PN6

* Boiler connection piece not included in delivery! LAS = air/flue gas system

11

Boilers / Multi-Fuel oil burner

Scope of delivery BK
BK50 BK100

BK250

Permanently condensing boiler,


including burner (oil or gas)

Permanently condensing boiler,


including burner (oil or gas)

Cable kit for 2-stage burner

Cable kit for 2-stage burner

Neutralization box, including 3 kg


granulate

Neutralization box, including 9 kg


granulate

Control, including
External temperature sensor
Flow sensor for heating circuit 1 (4 m)
DHW sensor (4 m)
Secondary flow sensor (4 m)
Plug for pump heating circuit 1
Plug for mixer heating circuit 1
Plug for DHW pump
Plug for circulation pump
Plug for feeding pump

Control, including
External temperature sensor
Flow sensor for heating circuit 1 (4 m)
DHW sensor (4 m)
Secondary flow sensor (4 m)
Plug for pump heating circuit 1
Plug for mixer heating circuit 1
Plug for DHW pump
Plug for circulation pump
Plug for feeding pump

Flue gas fan

Flue gas fan

Brush (flue gas passes + boiler body)

Brush (flue gas passes + boiler body)

4 pieces HT elbow pieces 87/


40 mm

4 pieces HT elbow pieces 87/


70 mm

12

Accessories

Immersion sensor
4 m without plug

042474

23,

Contact sensor
4 m without sensor

042473

29,

Heating circuit 2 sensor kit


containing:
Contact sensor 4 m
Plug 52
Plug 7/ N
Plug 12/13/N

042470

40,

042558

19,

Collector sensor
1,5 m with plug 53

042472

21,

Sensor for additional boiler


4 m with plug 59

042573

19,

Upper buffer temperature sensor


4 m with plug 45

042556

19,

Central buffer temperature sensor


4 m with plug 46

042557

19,

Lower buffer temperature sensor/


Collector sensor
4 m with plug 54

042561

19,

Plug 40
Set value output 0 10V

042553

5,

Plug 41
eBus

042621

5,

Plug 45
Upper buffer temperature sensor

042624

5,

Plug 46
Central buffer temperature sensor

042625

5,

Plug 47
Secondary flow sensor

042719

5,

Plug 53
Collector sensor

042631

5,

Plug 54
Lower buffer temperature sensor

042632

5,

Plug 55
Set value input 0 10V

042571

5,

Plug 59
Sensor for additional boiler

042633

5,

Secondary flow sensor


4 m with plug 47

BK50 BK250

Boilers / Multi-Fuel oil burner

Article
No.

Products

(essential for BK50 BK250, but not when operated


in cascade or in buffer mode or if a hydraulic switch is used)

(essential for cascade, buffer operation and


if a hydraulic switch is used)

(switch-off sensor for buffer loading)

13

Accessories
Article
No.

Sequence control SE6301OGZ


for 2 heating circuits; 1 hot water circuit;
circulation pump
including plug 41
without sensor

042477

338,

Sequence control SE6320OGZ


for 2 heating circuits; 1 hot water circuit;
1 circulation pump and additional
activation of an external 2-stage
oil or gas burner
without plug 41
without sensor

048459

471,

Remote control MB6102


-ComfortSetting options for all functions as
with master control

056535

Remote control FB6203


-StandardAdjustable for
2 x heating circuits
1 x hot water circuit
including plug 41

042479

90,

eBus LAN interface RC7000 WEB Access


including supply and software RC7000 Light
for distance control via internet

050747

519,

Upgrade RC7000 Professional


visualization of the heating facility
unlimited possibilities for recording
the measured values
setting of all parameters
graphic analysis of the records

055803

734,

Auxiliary board ZSP101


for transforming a potential-free or 230 V
inlet to a 0 10 V signal
including casing and plug

056536

246,

Boilers / Multi-Fuel oil burner

Products

Condensate pump
for neutralization box
max. delivery height 3 m
including 3 m hose

BK50 BK100

044958

208,

Condensate pump
for neutralization box
max. delivery height 4 m

BK250

046299

238,

BK50 BK250

036425

47,

Fault sensor
acoustic-optic for condensate pump

14

Accessories
Article
No.

Filter basket

BK250

046309

157,

Filter basket including activated coal

BK250

049484

210,

Active coal for operation with oil refill package 0,5 kg

BK250

049485

53,

050706

208,

056615

202,

Hydraulic switch WST60 21


Delivery rate 3 m/ h; connection 1

044963

222,

Insulation for WST60


HDPU foam half-shells 25 mm

044964

88,

Wall mounting for WST60


2 pieces; projection 100 mm

044965

75,

Hydraulic switch WST80 34


Delivery rate 7 m/ h; connection 1 1/2

044966

272,

Insulation for WST80


HDPU foam half-shells 35 mm

044967

144,

Wall mounting for WST80


2 pieces; projection 125 mm

044968

63,

Reduction piece (241) black


5/4 inside 1 1/2 outside

044969

4,

Reducing socket (246) black


2 inside 1 1/2 outside

044970

19,

Hydraulic switch WST120


delivery rate 12 m/h; connection DN65 (2 1/2)

056401

1.115,

Insulation for WST120


PU rigid foam half-shells

056404

651,

Hydraulic switch WST160


delivery rate 21 m/h; connection DN80 (3)

056402

1.461,

Insulation for WST160


PU rigid foam half-shells

056403

662,

GOK
Fuel filter / venting combination

Boilers / Multi-Fuel oil burner

Products

(for venting, a vacuum pump 050708 is required)

Afriso
Automatic fuel filter / venting combination

15

Accessories

Boilers / Multi-Fuel oil burner

Flue gas system kits concentric connecting pipe VL


Certificate number CE 0036 CPD 9169 003

VL80/125
Connecting pipe to the stack
PP/white

Products

Article
No.

BK50 BK70

031249

398,

BK100
(BK70)*

037769

643,

BK250

046218

395,

consisting of:
- boiler connection piece from
DN160/110
to DN125/80 ST/PP
- conc. bend DN125/80 87,
- conc. revision tube DN125/80,
- conc. tube 1000 mm DN125/80,
- conc. revision bend DN125/80,
- conc. tube 500 mm DN125/80,
- conc. wall bushing
DN125/80, PE/PP, with wall chuck

VL110/160
Connecting pipe to the stack
PP/white
consisting of:
- boiler connection piece DN160/110
- conc. bend DN160/110 87,
- conc. revision tube DN160/110,
- conc. tube 1000 mm DN160/110,
- conc. revision bend DN160/110,
- conc. tube 500 mm DN160/110,
- conc. wall bushing
DN160/110, PE/PP, with wall chuck
* depending on the flue gas pipe calculation,
you can also equip a BK70

VL160 Connecting pipe


consisting of:
- PP bend DN160, 87
- PP tube 2 m with bushing
and sealing
- PP revision bend DN160, 87
- PP tube 1 m with bushing
and sealing
- wall chuck DN160
- cover plate DN160

16

Accessories
Flue gas system kits chimney stack pipe SL
SL80
SL80
SL80
SL80
SL80

SL110
SL110
SL110
SL110
SL110

DN80 PP
DN80 PP
DN80 PP
DN80 PP
DN80 PP

ca. 8 m
ca. 10 m
ca. 12 m
ca. 14 m
ca. 16 m

BK50 BK70

031250
031251
031252
031253
031254

355,
383,
411,
443,
482,

DN110 PP
DN110 PP
DN110 PP
DN110 PP
DN110 PP

ca. 8 m
ca. 10 m
ca. 12 m
ca. 14 m
ca. 16 m

BK100
(BK70)*

037768
037767
037772
037771
037770

434,
498,
560,
624,
687,

BK250

046219

466,

Products

Article
No.

031997
S02119

756,
1.179,

033594
033523
033524
033554
033555
033556
033569
033617
033613
033599

561,
116,
163,
120,
120,
145,
249,
180,
468,
143,

S01734
S01735

1.016,
1.016,

S02120
S02121

1.643,
1.643,

S01736
S02122

974,
1.536,

*depending on the flue gas pipe calculation,


you can also equip a BK70

SL160 DN160 PP

BK250
BK20 BK100

consisting of:
- PP revision tube with screwing cover
- PP bend DN160, 87
- support DN160
- spacer PP plastic (6x)
- stack cover with final tube piece
(without extension tubes!)

Flue gas system kits for chimney outside the building AW


Basic kit
external chimney AW
PP stainless steel / height ca. 6 m
DN80/125
DN110/160

BK50 BK100

conc. external wall connection


conc. tube 500 mm
conc. tube 1000 mm
conc. bend 30
conc. bend 45
conc. bend 87
conc. revision tube
conc. final tube piece
conc. roof lead-through
wall mounting ES DN225

BK250

Basic kit
external wall-pitched roof
lead-through AWS
PP stainless steel / height ca. 6 m
DN80/125
Roofing tile black
terracotta
DN110/160
Roofing tile black
terracotta

BK50 BK100

Basic kit
external flat roof lead-through AWF
PP stainless steel / height ca. 6 m
Roof passing flat roof flashing
aluminium / adjustable 0 15
DN80/125
DN110/160

BK50 BK100

17

Boilers / Multi-Fuel oil burner

consisting of:
PP cleaning tube
PP tube
brace including bearing rail, bend and foot
spacer PP plastic
chute cover with outlet tube

Article
No.

Products

Certificate number CE 0036 CPD 9169 003

Accessories

Boilers / Multi-Fuel oil burner

Flue gas system kit for loft-installed boiler DZS and DZF

Article
No.

037541
037540
S02123
S02124

375,
375,
993,
993,

031242
031244
033602
033603

73,
73,
95,
95,

031352
033606

58,
64,

Products

Article
No.

Boiler connection piece


DN160/110 to bushing DN125/80
Necessary if other flue gas systems
are used.

BK50 BK70

031424

93,

Boiler connection piece


DN160/110
Necessary if other flue gas systems
are used.

BK100
(BK70)*

033627

87,

Certificate number CE 0036 CPD 9169 003


consisting of:
conc. revision tube
conc. tube
conc. bend
conc. roof lead-through
fixation

Products

Basic kit for


loft-installed heat plant
for pitched roof lead-through
and flat roof lead-through
DSZ80/125 black
terracotta
DSZ110/160 black
terracotta

BK50 BK70
BK100
(BK70)*

* depending on the flue gas pipe calculation,


you can also equip a BK70

Roofing tile for


pitched roof lead-through
DN80/125

black
terracotta
DN110/160 black
terracotta

BK50 BK70
BK100
(BK70)*

* depending on the flue gas pipe calculation,


you can also equip a BK70

Flat roof flashing


for flat roof lead-through
aluminium/adjustable 0 15
DN80/125
DN110/160
* depending on the flue gas pipe calculation,
you can also equip a BK70

Extension parts and accessories for flue gas system kits

* depending on the flue gas pipe calculation,


you can also equip a BK70

18

BK50 BK70
BK100
(BK70)*

Accessories
Extension parts and accessories for flue gas system kits

Concentric tube 0,25 m


PP/white
DN80/125

031214

36,

Concentric tube 0,5 m


PP/white
DN60/100
DN80/125
DN110/160

045770
031215
033515

35,
47,
53,

Concentric tube 1,0 m


PP/white
DN60/100
DN80/125
DN110/160

045771
031216
033516

49,
62,
82,

Concentric tube 2,0 m


PP/white
DN60/100
DN80/125
DN110/160

045772
031217
033517

101,
121,
164,

Concentric bend 15
PP/white
DN80/125
DN110/160

031222
033541

49,
61,

Concentric bend 30
PP/white
DN80/125
DN110/160

031223
033542

49,
61,

Concentric bend 45
PP/white
DN60/100
DN80/125
DN110/160

045775
031224
033543

38,
50,
62,

Concentric bend 87
PP/white
DN60/100
DN80/125
DN110/160

045776
031225
033544

46,
59,
75,

Concentric revision bend


PP/white
DN60/100
DN80/125
DN110/160

045778
031228
033565

79,
111,
120,

Concentric revision tube


PP/white
DN60/100
DN80/125
DN110/160

045777
031229
033566

78,
97,
103,

Products

Boilers / Multi-Fuel oil burner

Article
No.

Certificate number CE 0036 CPD 9169 003

Connecting pipe

19

Accessories

Boilers / Multi-Fuel oil burner

Extension parts and accessories for flue gas system kits

Article
No.

PP tube with bushing and sealing


0,25 m
DN80
DN110
DN160

031210
033499
046256

8,
8,
19,

PP tube with bushing and sealing


0,5 m
DN60
DN80
DN110
DN160

045767
031211
033500
046257

7,
10,
12,
27,

PP tube with bushing and sealing


1,0 m
DN60
DN80
DN110
DN160

045768
031212
033501
033509

11,
16,
23,
39,

PP tube with bushing and sealing


2,0 m
DN60
DN80
DN110
DN160

045769
031213
033502
033510

15,
28,
37,
60,

PP bend 15
DN80
DN110
DN160

031218
033525
046258

7,
10,
27,

PP bend 30
DN80
DN110
DN160

031219
033526
046259

7,
10,
27,

PP bend 45
DN60
DN80
DN110
DN160

045773
031220
033527
046254

6,
7,
10,
26,

PP bend 87
DN60
DN80
DN110
DN160

045774
031221
033528
033536

6,
7,
12,
30,

PP revision tube
with screwing cap
DN60
DN80
DN110
DN160

045779
031227
033561
046255

22,
32,
44,
92,

045780
031230
033571
033572

4,
5,
6,
7,

045783
031972
033623
033625

165,
198,
217,
287,

033621

218,

Certificate number CE 0036 CPD 9169 003

Products

Chimney stack pipe

Spacer PP plastic
DN60
DN83/75
DN110/100
DN160
Mount one spacer every 2,5 m
Stack cover with final tube piece,
stainless steel
DN60
DN80
DN110
DN160
Final tube piece made of PP-UV,
black
DN160

20

Accessories
Extension parts and accessories for flue gas system kits

Concentric tube 0,5 m


PP/ stainless steel
DN80/125
DN110/160
DN160/225

031537
033518
033523

46,
48,
116,

Concentric tube 1,0 m


PP/ stainless steel
DN80/125
DN110/160
DN160/225

031951
033519
033524

62,
86,
163,

Concentric tube 2,0 m


PP/ stainless steel
DN80/125
DN110/160

031952
033520

129,
164,

Concentric bend 15
PP/ stainless steel
DN80/125
DN110/160
DN160/225

031953
033545
054249

49,
71,
139,

Concentric bend 30
PP/ stainless steel
DN80/125
DN110/160
DN160/225

031954
033546
033554

49,
71,
120,

Concentric bend 45
PP/ stainless steel
DN80/125
DN110/160
DN160/225

031955
033547
033555

50,
73,
120,

Concentric bend 87
PP/ stainless steel
DN80/125
DN110/160
DN160/225

031956
033548
033556

59,
88,
145,

Concentric revision tube


PP/ stainless steel
DN80/125
DN110/160
DN160/225

031957
033567
033569

106,
132,
249,

031976
033632

132,
139,

Products

Boilers / Multi-Fuel oil burner

Article
No.

Certificate number CE 0036 CPD 9169 003

External chimney

Concentric air intake


including closing cap
PP/ stainless steel
DN80/125
DN110/160
necessary from 50 kW on

21

Accessories

Boilers / Multi-Fuel oil burner

Extension parts and accessories for flue gas system kits

Products

Article
No.

PP revision bend
DN160, 87

BK250

033559

114,

Wall chuck
DN160

BK250

033591

52,

Cover plate
DN160

BK250

033585

35,

031962
033597

38,
39,

031963
031964

57,
57,

031961

80,

BK50 BK70

031214

36,

Concentric pipe 0,5 m


PP/white
DN80/125
DN110/160

BK50 BK70
BK100

031215
033515

47,
53,

Concentric pipe 1,0 m


PP/white
DN80/125
DN110/160

BK50 BK70
BK100

031216
033516

62,
82,

Concentric pipe 2,0 m


PP/white
DN80/125
DN110/160

BK50 BK70
BK100

031217
033517

121,
164,

Certificate number CE 0036 CPD 9169 003

Continue external chimney

Wall holder, adjustable


stainless steel
DN125
DN160

Extension for wall holder


stainless steel
DN125 adjustable from 47,5 140 mm
DN160/DN225 adjustable from
135 233 mm
Extension
for wall bracket
stainless steel/DN125
adjustable from 64 150,5 mm

Extension parts and accessories for flue gas system kits


Loft-installed boiler DZS and DZF
Concentric tube 0,25 m
PP/white
DN80/125

22

Accessories
Flexible flue gas systems

Article
No.

Suspension including UV protection


for flexible tube
DN80
DN110

BK50 BK70
BK100

031237
033581

18,
40,

PP flexible tube
DN80
roll 12,5 m
DN110
roll 15 m

BK50 BK70
BK100

031232
033634

398,
852,

PP flexible tube roll 25 m


DN80
DN110

BK50 BK70
BK100

031233
033635

754,
1.387,

Screw coupling for flexible tube


DN80
DN110

BK50 BK70
BK100

031234
033578

96,
150,

Upper screw coupling


for flexible tube with bushing
DN80
DN110

BK50 BK70
BK100

031235
033579

49,
162,

Revision piece for flexible pipe


including screwing
DN80
DN110

BK50 BK70
BK100

031236
033580

120,
173,

Entering support for flexible pipe


with 20 m rope
DN80
DN110

BK50 BK70
BK100

031238
033636

107,
137,

BK50 BK70
BK100

031230
033571

5,
6,

Stack cover
with final tube piece
DN80 / black
DN80 / terracotta
DN110 / black
DN110 / terracotta
DN160 / stainless steel

BK50 BK70
BK50 BK70
BK100
BK100
BK250

031247
031248
033618
033619
033621

79,
79,
111,
111,
218,

Flue gas pipe support


(bend, support bar, support)
DN80
DN110
DN160 (without bend)

BK50 BK70
BK100
BK250

031231
033574
033576

41,
46,
116,

Spacer for flexible pipe


DN80
DN110
Mount one spacer every 2,5 m

Boilers / Multi-Fuel oil burner

Products

Certificate number CE 0036 CPD 9169 003

23

Boilers / Multi-Fuel oil burner

hydraulic systems

externally
controlled

Types of application

Hydraulic system

Boiler
09-076 5/6/7/8/9 or 10

BK50 BK100

Hot water circuit


05-076 1

Heating circuit 1
07-076 1 or 2

two heating circuits + DHW + solar

Heating circuit 2
07-076 1 or 2

#500 drawing is just a function diagram 25.01.2013

externally
controlled

Hydraulic system
BK50 BK100
two heating circuits + DHW + solar + hydraulic switch
#501 drawing is just a function diagram 14.02.2013

Types of application

*see instruction sheet hydraulic switch


Boiler
09-076 5/6/7/8/9 or 10

Hot water circuit


05-076 1

Heating circuit 1
07-076 1 or 2

Cascade manager/heat generator 1


11-076 1

Heating circuit 2
07-076 1 or 2

These schemes are just for illustration, they do not replace a professional planning by the executing companies.
More schemes on request.

24

hydraulic systems

Boilers / Multi-Fuel oil burner

externally
controlled

Types of application

Hydraulic system
BK50 BK100
two heating circuits + buffer + solar
#502 drawing is just a function diagram 25.01.2013

Boiler
09-076 5/6/7/8/9 or 10

Hot water circuit


05-076 1

Heating circuit 1
07-076 1 or 2

Heat manager
06-076 4

Heating circuit 2
07-076 1 or 2

Cascade manager/heat generator 1


11-076 1

Control settings

Sensor 46 can also be assigned to sensor 45 via the service tool, so it is not needed.

Boiler 1
U02
Master

Boiler 2
U03
Slave

Settings MB
MB master no.

5, 6, 7, 8, 9, 10

5, 6, 7, 8, 9, 10

11

12

BOILER
09-76 Application type
04-27 eBus heat generator address
AUXILIARY BOILER
04-27 eBus heat generator address

09-13 Energy restraint

Heat manager

0
2
blanked

06-76 Application type

06-01 Maximum heating power system

Depending on
boiler types,
e.g. 2 x BK100

06-00 Max. hot water loading capacity

e.g. 120

06-03 Buffer active

06-04 Raising heat generators setpoint,


setpoint

15

06-08 Raising heat generators setpoint,


setpoint hot water

06-10 P range heat manager

06-11 Reset time heat manager

20

06-17 Max. incline of setpoint

06-20 Change of sequence

240

CASCADE MANAGER

blanked

Heat generator 1
11-76 Application type

Depending on
boiler types,
e.g. BK100

70

Depending on
boiler types,
e.g. BK100

11-03 Minimum power heat generator (%)

70

11-07 eBus unit goal heat generator

11-02 Nominal power heat generator (kW)

Boiler 1

Boiler 2

120

11-03 Minimum power heat generator (%)


Heat generator 2
11-02 Nominal power heat generator (kW)

120

GLOBAL FUNCTIONS
04-20 eBus unit no.

Hydraulic system
BK50 BK100
Cascade + hydraulic switch
#506 drawing is just a function diagram 25.01.2013

U02 HEATING CIRCUIT 1


07-76 Application type

Before connecting eBus, reprogram boiler 2!


1) MB master number > 7
2) Boiler > eBus heat generator address > 12
3) Global functions > eBus unit no. > 3
4) Start eBus scan!

These schemes are just for illustration, they do not replace a professional planning by the executing companies.
More schemes on request.

25

Boilers / Multi-Fuel oil burner

hydraulic systems

L/ N main 230V ~ 50Hz

Types of application

Hydraulic system
BK50 BK100
four heating circuits + follower controller + RC7000
#509 drawing is just a function diagram 14.02.2013

U02 Boiler
09-076 5/6/7/8/9 or 10

U02 Hot water circuit


05-076 0

U02 Heating circuit 1


07-076 1 or 2

U03 Heating circuit 1


07-076 1 or 2

U02 Heating circuit 2


07-076 1 or 2

U03 Heating circuit 1


07-076 1 or 2

U03 Hot water circuit


05-076 0

Sensor 46 can also be assigned to sensor 45 via the service tool, so it is not needed.

44

Control settings

45*

Boiler 1
U02
Master

46

Boiler 2
U03
Slave

Settings MB
MB master no.

11 or 12

11 oder 12

BOILER
09-76 Application type
04-27 eBus heat generator address

11

12

04-27 eBus heat generator address

09-13 Energy restraint

AUXILIARY BOILER

HEAT MANAGER
06-76 Application type

500

e.g. 250

06-04 Raising heat generators setpoint,


setpoint

15

06-08 Raising heat generators setpoint,


setpoint hot water

06-10 P range heat manager

06-11 Reset time heat manager

20

06-17 Max. incline of setpoint

06-20 Change of sequence

06-00 Max. hot water loading apacity

Boiler 2
Unit 3

06-03 Buffer active

06-01 Maximum heating power system

Boiler 1
Unit 2

2
blanked

CASCADE MANAGER

blanked

Heat generator 1
11-76 Application type

11-02 Nominal power heat generator (kW)

250

11-03 Minimum power heat generator (%)

70

11-02 Nominal power heat generator (kW)

250

11-03 Minimum power heat generator (%)

70

11-07 eBus unit goal heat generator

04-76 Application type

04-20 eBus unit no.

Heat generator 2

eBus 41

GLOBAL FUNCTIONS

U02 HEATING CIRCUIT 1

Hydraulic system

07-76 Application type

BK250
Cascade
+ hydraulic
switch
Skizze gilt
nur als Funktionsschema
#1502

07.05.2014

#1502 drawing is just a function diagram 25.01.2013

Before connecting eBus, reprogram boiler 2!


1) MB master number > 7
2) Boiler > eBus heat generator address > 12
3) Global functions > eBus unit no. > 3
4) Start eBus scan!

These schemes are just for illustration, they do not replace a professional planning by the executing companies.
More schemes on request.

26

Multi-Fuel oil burner

Boilers / Multi-Fuel oil burner

Multi-talents that convince:


KROLL multi-fuel oil burners...

Multi-Fuel oil burner with ZVP tube

KG/UB20 KG/UB200

UBK1 UBK2

Delivered units may differ from the pictures.

27

Multi-Fuel oil burner

Boilers / Multi-Fuel oil burner

The fuels and their environmental compatibility


Mineral, vegetable and animal oils can be used as fuel without significant modifications
to the burner.
No special tools are n
ecessary. All you have to do is turn a dial to re-adjust the pre-heating
temperature and the c
ombustion air according to the fuel to be used.
Vegetable oils/fats
Animal oils/fats
Mineral oils
Due to ever increasing costs of mineral oils, vegetable oils have become more and
more important.
Their energetic density is very close to the values of heating oil. Vegetable oils are
renewable, CO2-neutral and do not contain any sulphur or heavy metals.

The technique of KG/UB20P KG/UB200


The combustible is atomized using compressed air at comparatively low p
ressures.
This allows larger nozzle diameters which prevent blocking of the nozzles even if polluted
or viscous oils are burnt. A separate fuel supply system sucks the combustible out of the
storage tank and pushes is reliably over large d
istances to the burner. Here, it is filtered
and preheated.
This is important for a consistently good quality of ignition and combustion of the oil.

Compressed air supply


In many industrial companies, there is a compressed air supply.
This can be used to supply the multi-fuel oil burners KG/UB20P KG/UB200 with compressed
air. If you do not have an existing c
ompressed air supply, you can create the c
ompressed
air that is necessary to run our burner using our e
specially developed Kroll compressors.
The have a long d
urability and are very silent in operation.

Fields of application
Warm air heaters are the most efficient way of heating commercial or industrial halls,
garages, production halls, w
arehouses etc.
And especially, if this is done with a multi-fuel oil burner instead of a conventional oil or
gas burner. Kroll offers a large range of warm air heaters which are matched especially
for this use.
Heating boilers of newer or older years of construction can easily be equipped with a
multi-fuel oil burner. You can decide which combustible you want to use:
If for economic or ecological reasons you always make the right choice.
KG/UB20P KG/UB200 are TUV-approved for technical rapeseed oil!

28

Multi-Fuel oil burner


Power range 14 54 kW
KG/UB20P

KG/UB20

KG/UB55

No.

2.224,
042510

2.224,
027142

2.888,
027143

kW

14 24

26 38

37 54

Oil consumption

kg/h

1,4 2,2

2,5 3,7

3,6 5,2

Electrical connection

V/Hz

Heating power with rapeseed oil

Electrical power consumption

kW

Weight

kg

230/50
0,46

1,21

1,21

11,5

15

15

140 170

150 170

150 170

88

90

90

KG/UB70

KG/UB100

KG/UB150

KG/UB200

2.986,
027144

2.986,
027145

3.884,
027146

3.884,
027147

Drilling in the burner plate

mm

Burner tube

mm

Boilers / Multi-Fuel oil burner

Model

Power range 56 190 kW


Model

No.
Heating power with rapeseed oil

kW

56 81

81 100

93 147

131 190

Oil consumption

kg/h

5,4 7,8

7,8 9,6

8,9 14,1

12,7 18,0

Electrical connection

V/HZ

230/50

Electrical power consumption

kW

1,21

1,21

1,35

1,35

Weight

kg

16

16

26

26

150 170

150 170

160 200

160 200

101

101

114

114

Drilling in the burner plate


Burner tube

mm
mm

Compressor UBK1
for KG/UB20P KG/UB100

Compressor UBK2
for KG/UB150 + KG/UB200

1.211,
030794

1.851,
033184

l/min

110

180

bar

2,8

3,8

Electrical power consumption

2,2

3,3

Power consumption

440

520

Model

No.
Air delivery
Pressure max.

Electrical connection

V/Hz

Length

mm

425

425

Width

mm

194

194

Height

mm

350

350

dB(A)

68

70

kg

10

12,5

Noise level
Weight

230/50

29

Boilers / Multi-Fuel oil burner

Multi-Fuel oil burner

Article
No.

KG/UB20P, KG/UB20 KG/UB55


KG/UB70 KG/UB100
KG/UB150 KG/UB200

056633

13,

Spacer flange with sealing


necessary if used with certain types of boilers

KG/UB20P, KG/UB20 KG/UB100


KG/UB150 KG/UB200

034129
034131

71,
71,

Patented ZVP tube for KG/UB20


only if used with heaters 25S and 40S

KG/UB20

038768

197,

Patented ZVP tube with ceramic fibre mat

KG/UB20P, KG/UB20 KG/UB55


KG/UB70 KG/UB100
KG/UB150 KG/UB200

038672
038770
038771

197,
260,
306,

Ceramic fibre mat 6 mm, price per metre


width 610 mm

KG/UB70 KG/UB200

034241

11,

Ceramic fibre plate


ca. 25 x 500 x 500 mm

KG/UB70 KG/UB200

039363

103,

Feed system for external oil tank,


fuel supply aggregate with preheated filter
and float suction

KG/UB20P, KG/UB20 KG/UB200

000901

961,

Feed system for external oil tank,


fuel supply aggregate with not preheated filter
and float suction

KG/UB20P, KG/UB20 KG/UB200

047550

665,

Feed system with storage tank, fuel supply aggregate,


preheated filter and float suction,
Tank content: 59 l / KG/UB70
Tank content: 109 l / KG/UB100 KG/UB200

KG/UB20 KG/UB70
KG/UB100 KG/UB200

000900
000891

1.196,
1.281,

Accessories
Suction mesh for burner tank

Products
1 pc. for
2 pcs. for
3 pcs. for

No matter if your boiler has got a combustion chamber made of stainless steel or cast
iron, our patented ZVP tube in combination with a ceramic fibre mat or plate ensures a
so-called hot combustion chamber.
The patented ZVP tube lowers the flue gas temperature, raises the CO2 values, lowers the
soot which is created and helps make the burner not start so often.
Does the burner fit onto my boiler?
Please check the dimensions. Especially the dimensions of the drilling of the burner plate
and the dimension of the burner tube. If these dimensions correspond to the dimensions
of the burners flame tube, the burner flange can be connected.

To be used for:

30

Installation length
[mm]

Outer
[mm]

ZVP125

Multi-Fuel oil burner KG/UB20P and KG/UB20


with warm air heaters

220

127

ZVP140

Multi-Fuel oil burner KG/UB20P, KG/UB20,


KG/UB55 with hot water boilers

220

142

ZVP160

Multi-Fuel oil burner KG/UB70, KG/UB100,


with hot water boilers

220

162

ZVP180

Multi-Fuel oil burner KG/UB150, KG/UB200,


with hot water boilers

220

182

Multi-Fuel oil heater

Boilers / Multi-Fuel oil burner

W401K
These units are particularly suitable to heat up car garages, warehouses etc.
They are completely equipped with burner basin and oil tank, easy to install and
immediately ready to use.
The cross-flow fan works silently and does not need much maintenance.
The 24 l tank has got an integrated oil strainer and an electromagnetic gear pump
to supply the burner basin with oil.
The integrated overflow switch turns the electromagnetic gear pump off in case of
a fault.
After ignition, an integrated thermostat switches on the cross-flow fan and the electromagnetic gear pump as soon as 55C are reached inside the c
ombustion chamber.
For a quick and thorough cleaning, we offer the suitable slag-solvent.
Observe your national regulations! No approval for Germany!

Delivered units may differ from the pictures.

31

Multi-Fuel oil heater

Boilers / Multi-Fuel oil burner

Power range 35 kW
Model

W401K

No.

2.550,
046888

Without fan
With fan

Nominal heat input

kW

35

Nominal heat output

kW

29

m/h

820

80

Air delivery
Temperature rise (T)
Oil consumption*

kg/h

1,9 2,8

V/A

230/0,4

kW

0,09

Flue gas pipe

mm

150

Tank content

litres

24

Width

mm

600

Length

mm

770

Height

mm

1170

Weight

kg

Electrical connection
Electrical power consumption

99

* Heating oil consumption: 1 kg/h = 1,17 l/h (at 15C)

Accessories

W401K

Fan V470

No.

Slag-solvent 2 x 0,5 l

No.

61,
000721

Burner basin

No.

69,
011639

Feed system for external oil tank,


fuel supply aggregate with not preheated filter and float suction
(only together with Art. No. 047500)

No.

665,
047550

Feed system for external oil tank,


fuel supply aggregate with preheated filter and float suction
(only together with Art. No. 047500)

No.

961,
000901

Float switch for fuel supply system

No.

316,
047500

32

Air heaters

LH120 LH530
Characteristics:
For wall mounting and ceiling mounting
Operation with outside air, mixed air and
recirculating air possible
Including air outlet grills
Heat exchanger made of Cu/Alu

LH620 LH930

Fans with blade rotor


These units are of compact construction and can easily be mounted anywhere. They are
designed both for mounting at walls or at the ceiling. They operate via the pipe system of
your central heating. The large range offers heaters from 10 118 kW of heat output.
The integrated heat e
xchanger is made from copper/aluminium for hot water as a heating
medium. The units have protection class IP54.
The multi-stage adjustable fans are perfect for the multitude of different needs on site.
They assure d
raught-free, area-wide and comfortable distribution of heat and air.
In order to calculate your requirements exactly, the Kroll consultant team is at your disposal.
Large power range
A wide range of models with a multi-stage fan perWiths an optimal solution to your
requirements.
Special versions
On request, also explosion-protected units as well as units for stables are available.
Suitable for every application
They can easily be c
hanged from wall mounting to ceiling mounting, which makes them
extremely versatile.
Low noise level
No noise pollution due to quiet operation.
Elegant design
Besides the powdered version LH (RAL 7035), all models are also available as version LH-X
with stainless steel casing.
Wide range of accessories
With the right accessories, a comfortable room climate becomes the most natural thing.

Delivered units may differ from the pictures.

33

Warm air heaters stationary

For heating and ventilating

Air heaters
Power range 11 44 kW

Warm air heaters stationary

Model

LH120

LH130

LH220

LH230

Air heaters
Casing powder-coated

No.

680,
038972

701,
038973

724,
038974

770,
038975

Heating performance range


Heating medium water, 90/70, air 15

kW

10,5 13,7

13,0 17,8

16,6 18,1

20,5 24,5

Air delivery

m/h

900 1.750

850 1.550

1.900 2.450

1.550 2.300

Electrical connection

V/ Hz

Current consumption

0,4

0,4

0,4

0,4

Length

mm

555

555

605

605

Depth

mm

280

280

280

280

Height

mm

390

390

440

440

Weight

kg

17

18

19

21

dB(A)

50

50

51

51

LH320

LH330

LH420

LH430

Noise level

Model

230/50

Air heaters
Casing powder-coated

No.

1.024,
038976

1.117,
038977

1.171,
038978

1.219,
038979

Heating performance range


Heating medium water, 90/70, air 15

kW

20,3 50,0

23,3 37,4

24,1 32,7

30,3 44,0

1.650 3.600

1.350 3.400

1.900 3.950

1.850 3.900

Air delivery

m/h

Electrical connection

V/ Hz

Current consumption

0,7

0,7

0,8

0,8

Length

mm

705

705

755

755

Depth

mm

280

280

280

280

Height

mm

540

540

590

590

Weight

kg

22

25

26

27

dB(A)

53

53

53

53

Noise level

On request, also explosion-protected units are available

34

230/50

Air heaters
Power range 40 120 kW
Model

LH520

LH530

LH620

LH630

Air heaters
Casing powder-coated

No.

1.269,
038980

1.325,
038981

1.449,
038982

1.566,
038983

Heating performance range


Heating medium water, 90/70, air 15

kW

29,2 40,1

36,0 54,0

42,1 48,6

54,4 64,7

2.450 5.200

2.200 4.900

4.550 6.700

4.250 6.200

Air delivery

m/h

Electrical connection

V/ Hz

Current consumption

1,4

1,4

1,04

1,04

Length

mm

805

805

855

855

Depth

mm

280

280

280

280

Height

mm

640

640

690

690

Weight

kg

30

32

32

36

dB(A)

53

53

52

52

LH720

LH730

LH920

LH930

Model

400/50

Warm air heaters stationary

Noise level

230/50

Air heaters
Casing powder-coated

No.

1.587,
038984

1.728,
038985

1.785,
038986

2.009,
038987

Heating performance range


Heating medium water, 90/70, air 15

kW

62,7 69,4

80,7 90,4

80,2 91,2

105,1 118,4

6.550 8.500

6.100 7.700

8.950 12.550

8.400 10.900

Air delivery

m/h

Electrical connection

V/ Hz

Current consumption

400/50
1,4

1,4

2,08

2,08

Length

mm

1205

1205

1405

1405

Depth

mm

280

280

280

280

Height

mm

690

690

690

690

Weight

kg

41

44

71

76

dB(A)

52

52

52

52

Noise level

On request, also explosion-protected units are available

35

Warm air heaters stationary

Accessories
Products

Article
No.

5-step switch
for max. 1,5 ampere

LH120 LH530

058499

223,

5-step switch
for max. 3 ampere

LH120 LH530

040120

275,

5-step switch
for max. 7 ampere

LH120 LH530

040121

311,

1-Step switch DST1

LH620 LH930

022071

119,

2-Step switch DST2

LH620 LH930

022072

315,

5-Step switch DST5-2

LH620 LH930

022074

682,50

5-Step switch DST5-4

LH620 LH930

022075

733,

5-Step switch DST5-7

LH620 LH930

022076

881,

5-Step switch DST5-10

LH620 LH930

022077

1.122,

Connector IP65
for 2 5 heaters

LH620 LH930

024361

199,

Room thermostat RT

LH120 LH930

006859

45,

Room thermostat RTI,


industrial version
IP54 (splash water-protected)

LH120 LH930

005434

61,

Room thermostat RTIA,


industrial version with
covered temperature adjuster,
IP54 (splash water-protected)

LH120 LH930

005951

93,

Room thermostat RTU


With analog clock timer
IP30

LH120 LH930

022078

259,

Day/night automatic control in plastic


casing, for night setback,
with digital clock, power reserve,
day and week programme,
1 room sensor included

LH120 LH930

006708

413,

Delivered accessories may differ from the pictures.

36

Accessories
Article
No.

Brackets for wall mounting

LH120 LH930

039024

81,

4 brackets
for ceiling mounting

LH120 LH930

042870

49,

Vertical air outlet galvanized

LH120 LH130
LH220 LH230
LH320 LH330
LH420 LH430
LH520 LH530
LH620 LH630
LH720 LH730
LH920 LH930

042871
042873
042874
042875
042876
042877
042878
042879

82,
104,
122,
143,
159,
180,
206,
232,

Filter box

LH120 LH130
LH220 LH230
LH320 LH330
LH420 LH430
LH520 LH530
LH620 LH630
LH720 LH730
LH920 LH930

042953
042954
042955
042956
042957
042958
042959
042960

311,
323,
338,
346,
359,
369,
380,
394,

Recirculation outlet

LH120 LH130
LH220 LH230
LH320 LH330
LH420 LH430
LH520 LH530
LH620 LH630
LH720 LH730
LH920 LH930

042880
042883
042884
042885
042886
042887
042888
042889

170,
180,
221,
232,
247,
282,
294,
305,

4-sides outlet

LH120 LH130
LH220 LH230
LH320 LH330
LH420 LH430
LH520 LH530
LH620 LH630
LH720 LH730
LH920 LH930

042881
042882
042890
042891
042892
042893
042894
042895

162,
173,
194,
221,
247,
282,
294,
305,

Air outlet cone

LH120 LH130
LH220 LH230
LH320 LH330
LH420 LH430
LH520 LH530
LH620 LH630
LH720 LH730
LH920 LH930

042896
042897
042898
042899
042900
042901
042902
042903

131,
141,
153,
165,
175,
211,
247,
282,

Warm air heaters stationary

Products

Delivered accessories may differ from the pictures.

37

Warm air heaters stationary

WARM AIR HEATERS


STATIONARY

25S 110S

140S 730S

Delivered unit may differ from the picture.

38

WARM AIR HEATERS


STATIONARY
The stationary Kroll warm air heaters offer you all
the advantages.
Without long heat up periods, the units ensure immediate heat
In production halls and factories
In greenhouses and garden centres
In exhibition halls
In stables and animal-rearing facilities
 In workshops and garages
In photo and film studios
In furniture warehouses
As special versions in process technology
In sports facilities of all kinds (painting shops, drying chambers etc.)
The Kroll stationary warm air heaters are
instantly ready for use
The warm air is instantly e
mitted into the required area, as o
pposed to an indirect heating system that
utilises steam or water, which often have long start up periods.
efficient
Direct firing converts up to 93 % of the energy into heat. Accessories such as room thermostats and/or
day/night auto switches help save energy consumption.
Installation costs are also kept to a minimum, when compared to a wet heating system, which contri
butes to a cost-effective package.

convenient
All units can utilise fresh air, secondary air and re-circulated air, which is particularly cost efficient and
cost-effective during the winter. There is also a summer switch, which enables ventilation through the
units in the summer months.
flexible
As standard versions, the units can be mounted in upright or vertical position, or suspended from the
ceiling. Or they can be equipped with an individually designed duct system to distribute the warm air
into several rooms.
We can offer the units with pressures of up to 1600 Pa. Special accessories such as air inlet filters, outlet
grills, controls, silencers etc. ensure that every possible heating scheme can be accomplished.
The units can be operated with oil burner, gas burners or multi-fuel oil burners.
reliable
These well-engineered heaters benefit from high quality stainless steel combustion chambers,
high quality components and efficient fans.
professional service
Kroll offers a complete professional service, offering our expertise to help calculate and design a warm
air solution for you, using our computer aided design programmes.
Of course, we also offer commissioning and servicing by our engineers if required.
Dimensions
in mm
Types

C1

25S

715

455

1275

910

130

40S

865

505

1500

1110

130

55S

975

585

1645

1195

130

70S

1085

665

1835

1425

180

95S

1150

765

1895

1545

180

110S

1150

765

1985

1545

180

140S 170S

1250

1025

2180

1780

1600

250

195S 260S

1750

1025

2180

1780

1600

250

290S 360S

2200

1025

2180

1780

1600

250

430S 490S

2200

1220

2645

2245

2020

300

580S 730S

2700

1220

2745

2245

2020

300

39

Warm air heaters stationary

environmentally friendly
Due to an efficient operation and the resulting low energy consumption, the amount of flue gas is up to
30 % lower, compared to a conventional heating system.

WARM AIR HEATERS


STATIONARY
Power range 28 55 kW
25S

40S

55S

25S

for duct
without outlet
hood

40S

for duct
without outlet
hood

55S

for duct
without outlet
hood

No.

2.440,
027700

2.569,
025458

3.214,
027701

3.325,
025458

3.788,
027702

3.861,
025458

Nominal heat input

kW

28

28

40

40

55

55

Nominal heat output

kW

25,5

25,5

37,5

37,5

50,5

50,5

m/h

1.650

1.650

2.900

2.900

3.700

3.700

Model

Warm air heaters stationary

Air delivery
External pressure

Pa

80

300*

100

300*

100

300*

Temperature rise

43

43

42

42

45

45

Oil consumption***

kg/h

2,36

2,36

3,40

3,40

4,64

4,64

Gas consumption
(natural gas E)

m3/h

2,70

2,70

3,86

3,86

5,30

5,30

Gas consumption (LPG)

kg/h

2,18

2,18

3,11

3,11

4,28

4,28

Electrical connection

V/Hz

230/50

230/50

230/50

230/50

230/50

0,44

**

0,80

**

1,50

**

Stainless steel heat exchanger

Outlet hood 3-way


with grill ZG2

Air intake grill

Electrical
power consumption

Flue gas pipe

kW

230/50

400/50

mm

130

130

130

130

130

130

Length

mm

715

715

865

865

975

975

Width

mm

455

455

505

505

585

585

Height

mm

1275

1275

1500

1500

1645

1645

kg

93

93

124

124

157

157

dB(A)

68

68

71

71

71

71

Weight (without burner)


Noise level

* Higher pressure available on request!


** Electrical power consumption depends on the chosen pressure!
*** Heating oil consumption: 1 kg/h = 1,17 l/h (at 15C)

Accessories

25S

40S

55S

Oil burner

No.

930,
027485

930,
027486

930,
027487

LPG burner

No.

1.413,
005821

1.602,
005822

1.602,
005822

Natural gas burner

No.

1.413,
005813

1.602,
005814

1.602,
005815

Multi-Fuel oil burner


KG/UB****

No.

2.224,
027142

2.224,
027142

2.888,
027143

**** More accessories on page 25.

40

WARM AIR HEATERS


STATIONARY
Power range 70 110 kW
70S

95S

110 S

70S

for duct
without outlet
hood

95S

for duct
without outlet
hood

110 S

for duct
without outlet
hood

No.

4.229,
027703

4.404,
025458

5.082,
030821

5.257,
025458

5.516,
027704

5.691,
025458

Nominal heat input

kW

70

70

95

95

110

110

Nominal heat output

kW

64

64

88

88

100

100

5.000

5.000

6.750

6.750

7.650

7.650

Model

Air delivery

m/ h

External pressure

Pa

100

300*

100

300*

100

300*

Temperature rise

44

44

44

44

44

44

kg/h

5,90

5,90

8,01

8,01

9,27

9,27

Gas consumption
(natural gas E)

m3/ h

6,75

6,75

9,16

9,16

10,61

10,61

Gas consumption (LPG)

kg/h

5,45

5,45

7,39

7,39

8,56

8,56

Electrical connection

V/Hz

230/50

Electrical
power consumption

kW

230/50

400/50

400/50

1,5

**

1,68

**

1,68

**

Stainless steel heat exchanger

Outlet hood 3-way


with grill ZG2

Air intake grill

mm

180

180

180

180

180

180

Length

mm

1085

1085

1150

1150

1150

1150

Width

mm

665

665

765

765

765

765

Height

mm

1835

1835

1895

1895

1995

1995

kg

191

191

245

245

265

265

dB(A)

68

68

69

69

69

69

Flue gas pipe

Weight (without burner)


Noise level

Warm air heaters stationary

Oil consumption***

* Higher pressure available on request!


** Electrical power consumption depends on the chosen pressure!
*** Heating oil consumption: 1 kg/h = 1,17 l/h (at 15C)

Accessories

70 S

95 S

110 S

Oil burner

No.

964,
005785

983,
006224

983,
006224

LPG burner

No.

1.780,
005824

1.780,
005824

1.780,
005824

Natural gas burner

No.

1.988,
005816

1.988,
005816

1.988,
005816

Multi-Fuel oil burner


KG/UB****

No.

2.986,
027144

2.986,
027145

2.986,
027145

**** More accessories on page 25.

41

WARM AIR HEATERS


STATIONARY
Power range 129 194 kW
140S

170S

195S

140S

for duct
without outlet
hood

170S

for duct
without outlet
hood

195S

for duct
without outlet
hood

No.

6.119,
021657

5.856,
021699

6.370,
021658

6.178,
021711

8.270,
021659

8.022,
021716

Nominal heat input

kW

129

129

163

163

194

194

Nominal heat output

kW

120

120

150

150

180

180

9.200

9.200

11.800

11.800

13.800

13.800

Model

Warm air heaters stationary

Air delivery

m/ h

External pressure

Pa

90

350*

100

350*

90

350*

Temperature rise

44

44

43

43

44

44

Oil consumption***

kg/h

10,88

10,88

13,74

13,74

16,36

16,36

Gas consumption
(natural gas E)

m 3/ h

12,44

12,44

15,72

15,72

18,71

18,71

Gas consumption (LPG)

kg/h

10,04

10,04

12,68

12,68

15,10

15,10

Electrical connection

V/Hz

1,5

**

Electrical
power consumption

400/50

kW

1,1

**

2,2

**

Outlet hood 3-way


with grill ZG2

Air intake grill

Flue gas pipe

mm

249

249

249

249

249

249

Length

mm

1250

1250

1250

1250

1750

1750

Width

mm

1025

1025

1025

1025

1025

1025

Height

mm

2180

1780

2180

1780

2180

1780

kg

399

399

405

405

495

495

dB(A)

73

73

73

73

75

75

Weight (without burner)


Noise level

* Higher pressure up to 1600 Pa as well as vertical units and special versions available on request!
** Electrical power consumption depends on the chosen pressure!
*** Heating oil consumption: 1 kg/h = 1,17 l/h (at 15C)

Accessories

140S

170 S

195S

Oil burner

No.

983,
006224

1.643,
005811

1.643,
005811

LPG burner

No.

2.124,
006009

2.124,
006009

2.124,
006009

Natural gas burner

No.

2.774,
006006

2.774,
006006

2.774,
006006

Multi-Fuel oil burner KG/UB****

No.

3.884,
027146

3.884,
027147

3.884,
027147

Additional charge for stainless steel


heat exchanger

on request!

on request!

on request!

Additional charge for stainless steel


heat exchanger with condensate drain

on request!

on request!

on request!

**** More accessories on page 25.

42

WARM AIR HEATERS


STATIONARY
Power range 250 326 kW
260S

290S

360S

260S

for duct
without outlet
hood

290S

for duct
without outlet
hood

360S

for duct
without outlet
hood

No.

8.889,
021618

8.622,
021720

10.249,
021660

10.201,
021725

10.658,
021661

10.416,
021730

Nominal heat input

kW

250

250

280

280

326

326

Nominal heat output

kW

230

230

260

260

300

300

18.400

18.400

20.600

20.600

23.400

23.400

Model

Air delivery

m/ h

External pressure

Pa

100

350*

80

350*

110

350*

Temperature rise

42

42

42

42

43

43

kg/h

21,08

21,08

23,61

23,61

27,49

27,49

Gas consumption
(natural gas E)

m3/ h

24,11

24,11

27

27

31,44

31,44

Gas consumption (LPG)

kg/h

19,46

19,46

21,79

21,79

25,37

25,37

Electrical connection

V/Hz

5,5

**

Electrical
power consumption

400/50

kW

3,0

**

3,0

**

Outlet hood 3-way


with grill ZG2

Air intake grill

Flue gas pipe

mm

249

249

249

249

249

249

Length

mm

1750

1750

2200

2200

2200

2200

Width

mm

1025

1025

1025

1025

1025

1025

Height

mm

2180

1780

2180

1780

2180

1780

kg

503

503

662

662

689

689

dB(A)

75

75

74

74

74

74

Weight (without burner)


Noise level

Warm air heaters stationary

Oil consumption***

* Higher pressure up to 1600 Pa as well as vertical units and special versions available on request!
** Electrical power consumption depends on the chosen pressure!
*** Heating oil consumption: 1 kg/h = 1,17 l/h (at 15C)

Accessories

260S

290S

360S

Oil burner

No.

1.643,
005811

2.186,
006196

2.186,
006189

LPG burner

No.

2.124,
006009

4.279,
021806

4.279,
021806

Natural gas burner

No.

2.774,
021669

4.949,
021793

4.949,
021793

Additional charge for stainless steel


heat exchanger

on request!

on request!

on request!

Additional charge for stainless steel


heat exchanger with condensate drain

on request!

on request!

on request!

43

WARM AIR HEATERS


STATIONARY
Power range 423 544 kW
430S

490S

580S

430S

for duct
without outlet
hood

490S

for duct
without outlet
hood

580S

for duct
without outlet
hood

No.

14.098,
021662

13.743,
021735

14.632,
021663

13.909,
021740

19.314,
021664

18.994,
021745

Nominal heat input

kW

423

423

489

489

544

544

Nominal heat output

kW

390

390

450

450

500

500

29.500

31.000

35.000

34.900

37.500

38.000

Model

Warm air heaters stationary

Air delivery

m/ h

External pressure

Pa

100

350*

120

350*

100

350*

Temperature rise

45

45

44

44

45

45

Oil consumption***

kg/ h

35,67

35,67

41,23

41,23

45,87

45,87

Gas consumption
(natural gas E)

m3/h

40,79

40,79

47,16

47,16

52,46

52,46

Gas consumption (LPG)

kg/h

32,92

32,92

38,05

38,05

42,33

42,33

Electrical connection

V/Hz

5,5

**

Electrical
power consumption

400/50

kW

5,5

**

7,5

**

Outlet hood 3-way


with grill ZG2

Air intake grill

Flue gas pipe

mm

299

299

299

299

299

299

Length

mm

2200

2200

2200

2200

2700

2700

Width

mm

1220

1220

1220

1220

1220

1220

Height

mm

2645

2245

2645

2245

2745

2245

kg

1004

1004

1015

1015

1185

1185

74

74

77

77

78

78

Weight (without burner)


Noise level

dB(A)

* Higher pressure up to 1600 Pa as well as vertical units and special versions available on request!
** Electrical power consumption depends on the chosen pressure!
*** Heating oil consumption: 1 kg/h = 1,17 l/h (at 15C)

Accessories

430S

490S

580S

Oil burner

No.

2.835,
021788

2.835,
006127

3.528,
021790

LPG burner

No.

5.381,
029326

5.381,
029326

6.712,
021810

Natural gas burner

No.

6.163,
029199

6.163,
029201

8.012,
021798

Additional charge for stainless steel


heat exchanger

on request!

on request!

on request!

Additional charge for stainless steel


heat exchanger with condensate drain

on request!

on request!

on request!

44

WARM AIR HEATERS


STATIONARY
Power range 598 652 kW
650S

730S

650S

for duct
without outlet
hood

730S

for duct
without outlet
hood

No.

20.550,
021665

19.370,
021750

20.909,
021666

20.302,
021755

Nominal heat input

kW

598

598

652

652

Nominal heat output

kW

550

550

600

600

42.600

42.600

48.300

48.300

Model

Air delivery

m/ h

External pressure

Pa

120

350*

140

350*

Temperature rise

44

44

42

42

kg/h

50,42

50,42

54,97

54,97

Gas consumption
(natural gas E)

m 3/ h

57,67

57,67

62,87

62,87

Gas consumption (LPG)

kg/h

46,54

46,54

50,74

50,74

Electrical connection

V/Hz

11,0

**

Electrical
power consumption

kW

400/50
7,5

Outlet hood 3-way


with grill ZG2

Air intake grill

Flue gas pipe

**

mm

299

299

299

299

Length

mm

2700

2700

2700

2700

Width

mm

1220

1220

1220

1220

Height

mm

2745

2745

2745

2745

kg

1196

1196

1248

1248

78

78

78

78

Weight (without burner)


Noise level

dB(A)

Warm air heaters stationary

Oil consumption***

* Higher pressure up to 1600 Pa as well as vertical units and special versions available on request!
** Electrical power consumption depends on the chosen pressure!
*** Heating oil consumption: 1 kg/h = 1,17 l/h (at 15C)

Accessories

650S

730S

Oil burner

No.

3.528,
021790

3.528,
021792

LPG burner

No.

6.712,
021810

6.712,
021810

Natural gas burner

No.

8.012,
021798

8.012,
021798

Additional charge for stainless steel


heat exchanger

on request!

on request!

Additional charge for stainless steel


heat exchanger with condensate drain

on request!

on request!

45

Accessories
Products

Article
No.

Floor standing unit frame

025S
040S
055S
070S
095S 110S
140S 170S
195S 260S
290S 360S
430S 490S
580S 730S

030501
030502
030503
030504
034587
021833
021834
021835
022100
021836

255,
270,
284,
308,
308,
308,
352,
584,
590,
593,

Wall brackets
for standing unit

025S
040S
055S
070S
095S 110S
140S 170S
195S 260S
290S 360S
430S 490S
580S 730S

030505
030506
030507
030508
034651
021842
011903
021843
022102
021844

213,
213,
274,
291,
294,
295,
295,
308,
308,
440,

Wall brackets
for horizontal unit

025S
040S
055S
070S
095S 110S
140S 170S
195S 260S

030509
030510
030511
030512
034713
021840
021841

213,
213,
273,
290,
395,
395,
407,

Base frame
for horizontal unit

025S
040S
055S
070S
095S 110S
140S 170S
195S 260S
290S 360S
430S 490S
580S 730S

030513
030514
030515
030516
034714
011906
021846
021847
022105
021848

187,
187,
201,
214,
214,
228,
235,
289,
324,
367,

Base frame
for ceiling suspension

025S
040S
055S
070S
095S 110S
140S 170S
195S 260S
290S 360S
430S 490S
580S

030517
030518
030519
030520
034715
011907
021850
021851
022107
021852

187,
187,
201,
214,
214,
228,
235,
289,
324,
367,

Burner cover

025S 055S
070S 110S
140S 170S
195S 260S
290S 730S

030469
030473
011910
011911
011912

359,
369,
369,
369,
445,

Warm air heaters stationary

Fixing devices

Burners

More accessories on request! Delivered accessories may differ from the picture.

46

Accessories
Products

Article
No.

Combustion air intake


Intake bend 90

025S 110S

021853

54,

Intake bend 45

025S 110S

011915

44,

Intake pipe 1 m length

025S 110S

021856

54,

Intake pipe 1 m length

025S 110S

021859

54,

Duct outlet accessories


310,
310,
310,
330,
339,
496,
600,
625,
806,
857,

110S
170S
260S
360S
490S
730S

030525
030526
030527
030528
021886
021887
011880
021888
022111
021889

417,
417,
417,
417,
432,
432,
506,
725,
881,
1.008,

110S
170S
260S
360S
490S
730S

030529
030530
030531
030532
021886
021887
011880
021888
022111
021889

417,
417,
417,
417,
432,
432,
506,
725,
881,
1.008,

Transition piece
to pocket air filter

025S
040S
055S
070S
095S 110S

030553
021938
021939
021940
034723

138,
138,
138,
162,
162,

Pocket air filter


(from 140S on, transition piece
included)

025S
040S
055S
070S
095S
140S
195S
290S
430S
580S

110S
170S
260S
360S
490S
730S

030556
030561
021966
021967
034726
021969
021970
021971
022127
021972

742,
742,
742,
860,
1.013,
1.078,
1.166,
1.246,
1.474,
1.917,

025S
040S
055S
070S
095S 110S
140S 170S
195S 260S

034182
034187
034192
034197
034202
021977
021978

580,
580,
580,
624,
631,
669,
746,

Duct hood, lengthwise

Duct hood, frontal

Flat filter kit

025S
040S
055S
070S
095S
140S
195S
290S
430S
580S
025S
040S
055S
070S
095S
140S
195S
290S
430S
580S
025S
040S
055S
070S
095S
140S
195S
290S
430S
580S

More accessories on request! Delivered accessories may differ from the picture.

47

Warm air heaters stationary

110S
170S
260S
360S
490S
730S

030537
030538
030539
030540
034719
011888
021897
021898
022113
021899

Duct hood, drawn round

Accessories
Electric accessories and oil filters for 25S 730S
Room thermostat RT,
IP30

No.

45,
006859

Room thermostat RTI,


industrial version IP54

No.

61,
005434

Room thermostat RTIA,


industrial version IP54

No.

93,
005951

Oil filter with return admixing

No.

63,
005330

Automatic heating oil deventilation device


with filter

No.

114,
006903

Day/night control for night setback, with digital clock, power reserve, day and week
programme, including 1 room sensor, in plastic box

No.

413,
006708

Day/night control for night setback, with digital clock, power reserve,
day and week programme, including 1 room sensor, in plastic box,
for 2 units with separate control box

No.

581,
006847

No.

113,
006577

Hours counter

Warm air heaters stationary

More accessories on request!

48

Ceiling fan
The easiest way to save energy:
Kroll ceiling fans
Due to natural lift, warm air rises directly under the ceiling,
and there, nobody needs it. Kroll ceiling fans recirculate
the warm air back downwards and help to save heating costs
considerably.
Characteristics:
high change of air
silent operation
high-power energy-saving motor
completely made of metal
long durability and safe operation

Warm air heaters stationary

Safety:
Ceiling fans have to be placed so that there is a minimum distance of 2,5 m
between the floor and the bottom edge of the fan blades.

Ceiling fans, also for air heaters and for all warm air heaters
Ceiling fan

No.

211,
006245

Speed control, continuos


for up to 5 ceiling fans

No.

174,
006735

Control for 1 12 ceiling fans,


including speed control and 1 room sensor

No.

484,
006900

Control for 1 12 ceiling fans,


including 2 room sensors, speed control
and digital clock, with day/night control

No.

759,
006901

Differential temperature control for 1 12


ceiling fans, including 2 room sensors

No.

275,
006902

Technical data
7,5 m

Colour

15 m

7,5 m

15 m

30 m

Electrical connection

45 m

white
V/Hz

230/50

Electrical power consumption

65

Max. current

0,35

Revolutions

rpm

300

Air change

m /h

15.000

Noise level

dB(A)

52

kg

9,5

Rotor diameter

cm

142

Construction height

cm

69

Packing dimensions

mm

235x255x690

Weight

49

Warm air heaters


gas

Warm air heaters stationary

Characteristics:
atmospheric burners (modulating)
for natural gas or LPG
electric ignition
modulating axial fan
for indoor use

NB2 NB11

The units are pre-set for operation with natural gas G20.
The kit to convert the unit to propane gas G31 and butane gas G30 is included in the
delivery (except units for Belgium).

Modulating gas warm air heaters, condensing units


This special gas warm air heater reaches a degree of efficiency of over 96%!

Power range 24 93 kW
Model

NB2

NB3

NB5

NB7

NB9

NB11

Axial fan
modulating burner
for indoor installation

No.

2.995,
054066

3.207,
054067

3.955,
054068

4.920,
054069

5.667,
054070

7.162,
054071

Nominal heat input

kW

24,3

31,5

44,2

58,9

78,8

93,3

Nominal heat output

kW

23,4

30,4

42,7

56,9

76,3

91,0

Air delivery

m/ h

1.800

2.800

4.000

5.700

7.700

9.000

Electrical connection

V/Hz

Electrical power supply

kW

230/50
0,155

0,240

0,346

0,465

0,650

0,940

Heat exchanger made of stainless steel

Natural gas

LPG

Electric ignition

Flue gas fan

Width

mm

665

745

925

1170

1720

1960

Length

mm

970

970

981

970

997

997

Height

mm

860

860

860

860

860

860

Weight

kg

75

80

105

125

185

225

DN100

DN100

DN100

DN100

DN100

DN100

Flue gas connection


Delivery air connection

DN100

DN100

DN100

DN150

DN150

DN150

10

10

10

10

10

10

dB(A)

44

53

55

54

56

60

Maximum flue gas pipe length (via roof)

Noise level

Delivered units may differ from the pictures.

50

accessories
Products

Article
No.

NB2/NB3/NB5
NB7/NB9/NB11

053291

155,

External room temperature


sensor

NB2/NB3/NB5
NB7/NB9/NB11

053293

64,

Brackets for wall mounting

NB2/NB3/NB5
NB7/ NB9/ NB11

053288

182,

Vertical flaps

NB5
NB7
NB9
NB11

034597
034598
034599
034600

64,
75,
90,
99,

Double pipe wall lead-through

NB2/NB3/NB5
NB7/ NB9/ NB11

053294
053295

268,
321,

NB2/NB3/NB5
NB7/ NB9/NB11

053296
053298

395,
449,

Warm air heaters stationary

Remote control with serial


communication to control
up to 16 heaters

Picture 31*

Double pipe roof lead-through

Picture 31*

More accessories on request! Delivered accessories may differ from the picture.
*Overall picture page 46

51

Accessories
Products

Article
No.

Bend with revision opening


DN100 m/w

NB2/NB3/NB5
NB7/ NB9/ NB11

059151

51,

Bend with revision opening


DN150 m/w

NB7/ NB9/ NB11

059152

72,

Extension pipe 1,0 m


DN100

NB2/NB3/NB5
NB7/ NB9/ NB11

034617

59,

NB2/NB3/NB5
NB7/ NB9/ NB11

034619

33,

NB7/ NB9/ NB11

034613

83,

NB7/ NB9/ NB11

034615

54,

Bend 45
DN100 m/w

NB2/NB3/NB5
NB7/ NB9/ NB11

034626

37,

Bend 45
DN150 m/w

NB7/ NB9/ NB11

034627

59,

Bend 90
DN100 m/w

NB2/NB3/NB5
NB7/ NB9/ NB11

034630

47,

Bend 90
DN150 m/w

NB7/ NB9/ NB11

034628

72,

Extension pipe 0,25 m


with measuring opening
DN100

NB2/NB3/NB5
NB7/ NB9/ NB11

040180

31,

Extension pipe 0,25 m


with measuring opening
DN150

NB7/ NB9/ NB11

040183

50,

Adjustable revision element


adjustable from 265 357 mm
DN100

NB2/NB3/NB5
NB7/ NB9/ NB11

040181

56,

Final piece (supply air pipe)


DN100

NB2/NB3/NB5

034637

82,

Final piece (supply air pipe)


DN150

NB7/ NB9/ NB11

034638

102,

Final piece (flue gas pipe)


DN100

NB2/NB3/NB5
NB7/ NB9/ NB11

034634

72,

NB2/NB3/NB5
NB7/ NB9/ NB11

034621

54,

NB2/NB3/NB5
NB7/ NB9/ NB11

034632

178,

Picture 20*

Extension pipe 0,5 m


DN100
Picture 21*

Extension pipe 1,0 m


DN150
Picture 20*

Extension pipe 0,5 m


DN150

Warm air heaters stationary

Picture 21*

Picture 24*

Picture 24*

Picture 22*

Picture 22*

Picture 31*

Picture 29*

Picture 28*

Rain cap
DN100
Picture 27*

T-piece with condensate drain


DN100 w/w
Picture 25*

More accessories on request! Delivered accessories may differ from the picture.
*Overall picture page 46

52

Warm air heaters stationary

53

Mobile heat plant


oil/gas

Mobile warm air heaters /


Mobile heat plant

HM

Delivered units may differ from the pictures.

54

Mobile heat plant


oil/gas
Power range 100 188 kW

Mobile and immediately ready to use the main characteristics


of the Kroll heat plant HM.
It is extremely suitable for use in various locations, such as tents, major construction sites,
warehouses etc., and as additional, temporary or replacement heating unit.
The Kroll heating unit HM200 is of compact construction. There are no parts or connections,
such as the air inlet/exhaust, protruding over the area of the HM200. It can easily be moved
by a fork lift, with its pallet-typebase it can easily be moved wherever it is n
eeded. It fits
crossways on a standard lorry and is easily and safely stackable, a fact,
that is especially interesting for rental companies.
All components of the unit, such as the burner, ventilator, control box etc. are enclosed
within the robust housing. The heating unit is therefore protected against abuse or misuse
by any unauthorized persons.
Furthermore, the models HM200 can be operated with a natural gas burner or an LPG
burner.
Furthermore, the unit is also available as a two-stage version (not HM100).
The unit works e
conomically:
The energy is converted directly and with a degree of efficiency of 93 %.
The unit can operate in various configurations with recirculated air, fresh air or a mixture
of both.
Due to the high pressure of 350 400 Pa, long warm air hoses can be connected.
The distribution of the warm air can be done via one or more warm air hoses at the same
time. This feature gives you more options in locating the unit on site.
The housing is galvanized and painted in a colour similar to RAL 7047.
The installation is easy to maintain, all component parts are positioned in a clearly
arranged manner, and, thanks to removable side-panels, easy to reach.
Mobile warm air heaters /
Mobile heat plant

Various accessories make the heat plants even more attractive:


tank
tank heating to preheat the oil
room thermostat for even more efficient use of the energy
weekly timer for day/night control of the unit

55

Mobile heat plant


oil/gas
Power range 100 188 kW
Model

No.

HM100

HM200

HM200/2
2-stage

9.000,
055666

10.974,
000080

12.854,
049333

Fuel

Fuel

Fuel

Nominal heat input

kW

100

188

133 / 188

Nominal heat output

kW

92

173

122 / 173

6.400

10.500

7.600 10.500

External pressure

Pa

350

350

175 / 350

Temperature rise

60

60

66 / 60

Air delivery

Oil consumption*
Electrical connection
Electrical power supply

m/ h

kg/h
V/Hz/A
kW

8,43

15,85

11,21 / 15,85

400/50/9,6

400/50/13,5

400 / 50 / 13,5

2,38

3,25

2,45 / 3,55

Oil supply line


Preheated oil filter

mm

180

180

180

Air outlet socket

mm

500

550

550

Air inlet socket

mm

500

550

550

Flue gas pipe

Width

mm

760

820

820

Length

mm

1900

2400

2400

Height (without crane eye)

mm

1370

1520

1520

Height (with crane eye)

mm

1460

1610

1610

kg

410

615

655

dB(A)

73

75

75

Weight
Noise level

* Heating oil consumption: 1 kg/h = 1,17 l/h (at 15C)

Model

Mobile warm air heaters /


Mobile heat plant

No.
Nominal heat input
Nominal heat output
Air delivery

kW
kW
m/ h

HM200F

HM200/2F
2-stage

HM200N

HM200/2N
2-stage

11.488,
042039

14.013,
050613

11.809,
042040

14.013,
050612

LPG

LPG

Natural Gas

Natural Gas

188

133 / 188

188

133 / 188

173

122 / 173

173

122 / 173

10.500

7.600 10.500

10.500

7.600 10.500

External pressure

Pa

350

175 / 350

350

175 / 350

Temperature rise

60

66 / 60

60

66 / 60

18,13

12,83/18,13

14,63

10,35/14,63

kW

3,25

2,45/3,55

3,25

2,45/3,55

Flue gas pipe

mm

180

180

180

180

Air outlet socket

mm

550

550

550

550

Air inlet socket

mm

550

550

550

550

Gas consumption (natural gas E)

m/h

Gas consumption (LPG)

kg/h

Electrical connection
Electrical power supply

V/Hz/A

400 /50 /13,5

Width

mm

820

820

820

820

Length

mm

2400

2400

2400

2400

Height (without crane eye)

mm

1520

1520

1520

1520

Height (with crane eye)

mm

1610

1610

1610

1610

kg

615

655

615

655

dB(A)

75

75

75

75

Weight
Noise level

56

Mobile heat plant


oil/gas
Accessories

HM100

HM200 /
HM200 2-stage/ N / F

Room thermostat IP54


10 m cable, plug included

No.

140,
000729

140,
000729

Belt

No.

20,
052494

20,
052494

Clock thermostat

No.

665,
056714

665,
056714

Warm air hose


7,6 m, 560 mm

No.

311,
026991

Connection piece 560 mm


for hose extension

No.

78,
026985

Transition piece von 560 mm


to warm air hose 525 mm

No.

143,
012527

Warm air hose


7,6 m 525 mm

No.

296,
005597

296,
005597

Connection piece 525 mm


for hose extension

No.

66,
002800

66,
002800

Hose distributor*
for 2 warm air hoses with 525 mm
each hose

No.

Hose distributor
for 3 warm air hoses with 525 mm
each hose

No.

Hose distributor
for 4 warm air hoses with 305 mm
each hose

No.

to fix the room thermostat

419,
012530

* On the air outlet and inlet side, 2 distributors are necessary!

Mobile warm air heaters /


Mobile heat plant

57

Mobile warm air heaters /


Mobile heat plant

Mobile warm air heaters


Mobile heat plant

Operation at up to -20C
Outlet temperature adjustable to 80C
As additional or temporary heating device during renovation works or when changing
an existing hot water heating system.
As energy-efficient warm air generator in combination with a ventilation device.
For process heat to defrost or dry (e.g. floor screed)
Creation of heating water and DHW for large events
Sport events (e.g. marathon)
Music festivals
Exhibitions

Delivered unit may differ from the picture.

58

Mobile warm air heaters


Mobile heat plant
Characteristics BKM120
degree of efficiency >99%
low temperature boiler
stackable
liftable by crane
especially compact construction
secondary side made of stainless stee

Power range 120 kW


Model

BKM120

No.

35.000,
052688
Fuel

Degree of efficiency

>99

Nominal heat output

kW

120

kg/h

9,6

20

80

m/h

4,5

-20

Oil consumption*
Temperature rise**
Maximum outlet temperature
Dimensioning volume flow**
Minimum operation temperature
Electrical connection

V/Hz

230/50

Width

mm

1100

Length

mm

2800

Height

mm

2100

Weight

kg

1700
Mobile warm air heaters /
Mobile heat plant

* Heating oil consumption: 1 kg/h = 1,17 l/h (at 15C)


** The temperature rise refers to the dimensioned volume flow.

Accessories

on request

59

Concrete
silo

Hot air for aggregates


The hot air heating unit
This unit serves to warm up
construction aggregates.
The hot air is fed through
pipes into the silo chamber
and there, under high
pressure, is blown at the
aggregates through special
nozzles.
The volume of air can be
regulated separately for
every silo chamber by using
dampers.

Mobile warm air heaters /


Mobile heat plant

The construction
aggregates stay pourable
even during severe frost.
The following types of
combustibles/heat transfer
media are possible:
Oil
Gas
Thermal oil with heat
exchanger
Thermal oil/air
(with already existing
thermal oil heating plant)
Steam with heat
exchanger (with already
existing steam generator)

Delivered unit may differ from the picture.

60

Hot air heating units (extract from the programme)


Type
Air delivery

m/ h

SH100

SH160

SH220

SH320

SH480

2.650

4.600

6.200

9.000

12.000

Air outlet temperature

89

87,5

87,5

90

87,5

Heating power

kW

92

158

213

317

480

Fan pressure

Pa

5370

5370

6850

7410

6850

Other power ranges on request.


It supplies warm water for the mixing
procedure as well as for the t ransport
inside the mixing vehicles.

The control of the mixing water


temperatures is done from the
control desk of the mixing master.

Warm water unit (extract of the programme)


Type

SH950

SH1500

SH2000

SH2500

SH3000

litres

950

1500

2000

2500

3000

Power

kW

100
180

140
240

180
300

220
420

220
420

Max. continuous output


at 45 C/10 C
at 70 C/10 C

l/h
l/h

4420
2580

5900
3440

7370
4300

10320
6020

10320
6020

Tank content

Kroll has got many years of experience by engineering many reliably working
units. Profit from our knowledge!

The medium hot air has got


convincing advantages:
The unit does not freeze.
No additional moisture
is mixed with the
aggregates.
No warm-water
preparation is necessary.

You do not have to supervise the unit all the time.


Automatic operation and
only little space needed.

Concrete
silo
Heat for concrete
The Kroll concrete silo heating systems do not only solve the problem of frozen aggregates
but also allow the production of warm concrete during the freezing periods.
Kroll concrete silo heating systems ensure a trouble-free mixing in winter.
In the building trade, the cold season generates a lot of problems. Snow and frost cause
delays or even bring processes to a standstill.
In this respect, the problems of frozen aggregates and freezing water are of crucial
importance. In order to s olve this problem, Kroll offers tailor-made heating systems for
concrete mixing plants which help you to be ready to deliver at any time and thus give
you an advantage compared to your c
ompetitors.
Kroll concrete silo heating units are individual.
They can be integrated into all silo types, e.g., tower silos, tandem silos or star silos.
The concrete silo heating systems are delivered as a unit of hot-air and hot-water heater.
The power specifications will be fitted to each specific project.

Air heater with


high-pressure fan

Hot air ~ 85 C

Ambient
temperature
max. -25C

Supply finish
KROLL

Mobile warm air heaters /


Mobile heat plant

Water heater
content: 950 3.000 l

Mixing water
(warm)

Heating
circle flow

Hot water boiler


STB 120C
Mixing water
(cold)

61

Mobile warm air heaters


oil/gas

Mobile warm air heaters /


Mobile heat plant

M150 M200

M70/M100

M25/M50

Delivered unit may differ from the picture.

62

Mobile warm air heaters


oil/gas
Efficient, reliable and applicable everywhere
The suitable unit for each need:
The heating powers go from 25 kW up to 188 kW.
The Kroll mobile warm air heaters are optimal
for heating halls, tents and sites
for keeping greenhouses or warehouses of all kinds frost-free
as additional heating in the cold season
for quick drying of new buildings
etc.
The integrated oil tank and the heating cartridge make the units M25 and M50
independent, space-saving and immediately ready for use. The models M70 to M200 have
a fuel supply pipe to be connected to an external tank and a preheated filter and are also
immediately ready for use.
... reliable
Thanks to the quality-brand oil burner and the powerful fan, reliable and efficient heating
is ensured.
... economical and e
nvironmentally friendly
Quality-brand oil burner and silent, yet powerful fan convert more than 90% of the energy
into heat.
... robust
The units construction and engineering ensure a long durability
... easy to maintain
All relevant elements and controls are easily accessible.
... efficient
Due to the high-power radial fans, the models M25R/M50 to M200 are particularly suitable
to warm air hose systems. This helps to heat tents or building sites efficiently from the outside.
With the recirculation air module, an efficient and cost-saving operation is ensured.

The units are also approved for operation with gas!

63

Mobile warm air heaters /


Mobile heat plant

Characteristics:
stainless steel combustion chamber
stainless steel heat exchanger
tank with heating cartridge
radial fan
oil burner
recirculating air o
peration possible
room thermostat c
onnection
integrated tank (M25/M50/optional M70)
oil filter
heating device for nozzle connection
preheated oil filter +
automatic heating oil de-aeration
single-line fuel supply pipe (M70/M100/M150/M200)
casters (M70/M100/M150/M200)
crane eye and forklift device
(M70/M100/M150/M200)

Mobile warm air heaters


oil/gas
Power range 25 71 kW
With oil burner

No.
With natural gas burner

No.
With LPG burner

No.

M25

M50

M70

3.456,
040720

4.331,
000296

5.215,
000301

M25N

M50N

M70N

3.846,
050600

4.983,
050602

6.006,
050604

M25F

M50F

M70F

3.846,
050601

4.826,
050603

5.900,
050605

M50U

M70U

6.730,
056382

7.520,
056383

With multi-fuel oil burner KG/UB

No.

No.

Recirculating air module


for units with oil burner

No.

221,
050620

264,
050621

305,
050622

Recirculation air module


for units with gas burner

No.

305,
050720

358,
050721

401,
050722

Nominal heat input

kW

25

51

71

Nominal heat output

kW

Air delivery

m/ h

22

46

64

1.350

2.600

4.740

External pressure

Pa

150

170

180

Temperature rise

58

59

56

Oil consumption*

kg/h

2,11

4,3

5,99

Gas consumption (natural gas E)

m/h

2,41

4,92

6,85

Gas consumption (LPG)

kg/h

Electrical connection

V/Hz/A

Electrical power supply

Mobile warm air heaters /


Mobile heat plant

237,
000781

Tank for M70


(only built in!) Content 74 litres

kW

1,95

3,97

5,53

230/50/1,75

230/50/4,4

230/50/6,4

0,403

0,69

1,47

Tank content

27

46

Flue gas pipe

mm

100

130

180

Air outlet socket

mm

295

385

445

Air inlet socket

mm

295

385

445

Width

mm

560

630

780

Length

mm

1140

1210

1490

Height

mm

1080

1050

1120

kg

105

138

134

dB(A)

68

72

78

Weight (with burner)


Noise level
* Heating oil consumption: 1 kg/h = 1,17 l/h (at 15C)
Possible ways to connect warm air hoses:

M25
M50

64

M25
M50

Mobile warm air heaters


oil/gas
Power range 100 188 kW
M100

M150

M200

6.258,
000282

7.847,
000284

8.994,
000287

M100N

M150N

M200N

7.059,
050606

8.420,
050608

8.899,
050610

M100F

M150F

M200F

6.954,
050607

8.259,
050609

8.686,
050611

M100U

M150U

M200U**

No.

8.670,
056384

10.150,
056385

10.800,
056386

Recirculating air module


for units with oil burner

No.

379,
050623

including recirculation air


module and burner cover

including recirculation air


module and burner cover

Recirculation air module


for units with gas burner

No.

474,
050723

including recirculation air


module and burner cover

including recirculation air


module and burner cover

Nominal heat input

kW

100

140

188

With oil burner

No.
With natural gas burner

No.
With LPG burner

No.
With multi-fuel oil burner KG/UB

Nominal heat output

kW

Air delivery

m/ h

90

125

173

5.400

7.300

10.200

External pressure

Pa

150

150

150

Temperature rise

63

58

60

Oil consumption*

kg/h

8,43

11,8

15,85

Gas consumption (natural gas E)

m/h

9,64

13,5

18,13

Gas consumption (LPG)

kg/h

Electrical connection

V/Hz/A

Electrical power supply

kW

7,78

10,89

14,63

230/50/6,1

400/50/5,6

400/50/7,2

1,38

1,5

2,6

Flue gas pipe

mm

180

180

180

Air outlet socket

mm

550

550

550

Air inlet socket

mm

550

2 x 520

2 x 520

mm

940

940

940

Width

mm

1880

2330

2450

mm

1280

1410

1640

kg

190

270

330

dB(A)

77

75

75

Weight (with burner)


Noise level

Mobile warm air heaters /


Mobile heat plant

Length
Height

* Heating oil consumption: 1 kg/h = 1,17 l/h (at 15C)


** Attention! Supply with wire protection 16 A (C16) necessary!
Possible ways to connect warm air hoses:

M100
M70
M100

M70
M100

"X"
M150/M200

M150

M200
65

Accessories
Products

Article
No.

M25 M200

000729

140,

M50
M70
M100/M150/M200

002419
012575
012527

91,
120,
143,

Distributor
for 2 warm air hoses with 254 mm
each hose

M25

037789

188,

Distributor
for 2 warm air hoses with 305 mm
each hose

M50
M70
M100

012566
012576
012528

216,
264,
330,

Distributor
for 3 warm air hoses with 305 mm
each hose

M100/M150

012529

291,

Distributor
for 4 warm air hoses with 305 mm
each hose

M150/M200

012530

419,

Connection piece
for hose extension for
warm air hoses with 305 mm

002873

34,

Connection piece
for hose extension for
warm air hoses with 405 mm

002909

60,

Connection piece
for hose extension for
warm air hoses with 525 mm

002800

66,

Connection piece
for hose extension for
warm air hoses with 560 mm

026985

78,

Air outlet box


for hoses with 405 mm

052622

397,

Air outlet box


for hoses with 550 mm

052623

410,

Room thermostat
IP54, 10 m cable, plug included

Mobile warm air heaters /


Mobile heat plant

Transition piece from heater to


1 warm air hose

425 mm
425 mm
525 mm

Flexible flue gas pipe


stainless steel

3 m / 100 mm
3 m / 130 mm
3 m / 180 mm

M25
M50
M70/M100/M150/M200

006305
006306
006307

222,
283,
362,

Flue gas pipe 1 m


steel plate, hot-dip aluminum,
material thickness 0,6 mm

100 mm
130 mm
180 mm

M25
M50
M70/M100/M150/M200

012473
012474
012477

19,
21,
23,

Flue gas bend 90

100 mm
130 mm
180 mm

M25
M50
M70/M100/M150/M200

012488
012489
012492

16,
23,
52,

M25
M50
M70/M100/M150/M200

012503
012504
012507

33,
37,
66,

Rain cap
for flue gas pipe

66

Accessories

Warm air hose

7,6 m 250 mm

Products

Article
No.

M25

059881

165,

005417

187,

005418

249,

005597

296,

026991

311,

(For connection to distributor 037789)

Warm air hose


with fixing strap and carying bag

7,6 m 305 mm

M25
(Direct connection)

M50 M200

(For connection to distributors)

Warm air hose


with fixing strap and carying bag

7,6 m 425 mm

M50
(Transition piece 002419 necessary)

M70

(Transition piece 012575 necessary)

Warm air hose


with fixing strap and carying bag

7,6 m 525 mm

Warm air hose


with fixing strap and carying bag

7,6 m 560 mm

M100 M200
(Transition piece 012527 necessary)

M150/M200
(Direct connection))

Mobile warm air heaters /


Mobile heat plant

67

Mobile oil-fired
heaters
MA oil-fired heaters with flue gas pipe
The units are suitable for all fields of heating. The oil
supply from the integrated tank is done via an integrated
high-pressure pump.
MA units can be operated with a warm air hose.

Power range 23 90 kW
Model

Nominal heat input


Air delivery

MA22

MA32

MA59

MA91

No.

1.722,
046325

2.574,
046439

2.867,
046440

3.274,
046441

kW

23,4

34,1

58,6

90,6

m/ h

550

1.150

2.500

4.300

Temperature rise

95

70

66

77

Oil consumption*

kg/h

1,85

2,70

4,64

7,17

Electrical connection

V/Hz

Electrical power supply

230/50

kW

0,3

0,37

0,85

1,14

Tank content

46

46

65

105

Flue gas pipe

mm

120

150

150

150

Room thermostat c
onnection

Width

Preheated oil filter


mm

482

482

555

690

Length

mm

1098

1209

1435

1740

Height

mm

664

738

940

1025

Weight

kg

43

55

81

110

Noise level at 1 m

dB(A)

69

72

72

75

Noise level at 2 m

dB(A)

65

69

70

71

Mobile warm air heaters /


Mobile heat plant

* Heating oil consumption: 1 kg/h = 1,17 l/h (at 15C)

Accessories

Products

Room thermostat
IP54, 10 m cable, plug included

Article No.

MA22, MA32, MA59, MA91

000729

140,

Flue gas pipe 1 m, stainless steel, 120 mm

MA22

046415

90,

Flue gas bend 90, stainless steel, 120 mm

MA22

046417

86,

Flue gas pipe rain cap, stainless steel, 120 mm

MA22

046419

79,

Flexible flue gas pipe 3 m, stainless steel, 150 mm

MA32, MA59, MA91

031267

304,

Flue gas pipe 1 m, 150 mm

MA32, MA59, MA91

012476

28,

Flue gas bend 90, 150 mm

MA32, MA59, MA91

012491

34,

Flue gas pipe T-piece 90, 150 mm

MA32, MA59, MA91

012501

76,

Flue gas pipe rain cap, 150 mm

MA32, MA59, MA91

012506

48,

Transition piece for warm air hose

300 mm

MA32

046410

158,

Transition piece for warm air hose

350 mm

MA59

046411

204,

Transition piece for warm air hose

400 mm

MA91

046412

240,

Warm air hose

7,6 m 305 mm

MA32

005417

187,

Warm air hose

7,6 m 425 mm

MA59

005418

249,

Warm air hose

7,6 m 457 mm

MA91

031902

255,

Delivered unit may differ from the picture.

68

Infrared oil heater

Characteristics:
Steel casing, powder-coated
Stainless steel reflector (height adjustable)
Compact construction
Silent operation
Tank included

Model

IR45
2.475,
058581

kW

45,5

Oil consumption*

kg/h

3,6

Electrical connection

V/Hz

230/50

Nominal heat input

Electrical power supply


Tank content

kW
l

Room thermostat c
onnection

Mobile warm air heaters /


Mobile heat plant

No.

0,37
65
+

Width

mm

712

Length

mm

1410

Height

mm

1053

Weight

kg

73

Noise level at 1 m

dB(A)

72

Noise level at 2 m

dB(A)

70

* Heating oil consumption: 1 kg/h = 1,17 l/h (at 15C)

69

Gas-fired
heaters

PE45 PE112

Mobile warm air heaters /


Mobile heat plant

P65 P85
PX65 PX105

P32 P45
PX32 PX45
Delivered units may differ from the pictures.

70

Gas-fired
heaters
The Kroll gas-fired heaters are
environmentally b
eneficial
By nature, gas is an e
cologically beneficial fuel. Kroll gas-fired heaters burn nearly residue
free.
efficient
The units burn with high efficiency. A room thermostat can be delivered to save energy.
variable
The power range goes from 15 to 111 kW. So the suitable heater for all approved fields of
operation.
sophisticated
Every unit has got a b
uilt-in pressure controller.
End fittings will be delivered as well. All of them are in accordance with the G
erman Industrial
Norm DIN 30697, thus in accordance with the European Norm CE
safe
The gas flame is constantly monitored by thermo elements and ionization electrode.
The gas supply stops immediately as soon as the gas flame would go out.
And the built-in protection thermostat prevents the unit from overheating.
unlikely to require much maintenance
Robust technology and extremely high manufacturing quality ensure flawless operation.
Characteristics:
Gas-fired heatersP
powder-coated steel casing
piezo ignition
silent yet powerful fan
compact construction
pressure controller with hose and hose breaking protection device
Mobile warm air heaters /
Mobile heat plant

Gas-fired heatersPX
powder-coated steel casing
automatic ignition
room thermostat c
onnection
silent yet powerful fan
compact construction
pressure controller with hose and hose breaking protection device
Gas-fired heatersPE
stainless steel casing
automatic ignition
suspended version
room thermostat c
onnection

71

Gas-fired
heaters
Power range 15 84 kW
Model

Nominal heat input

P32

P45

P65

P85

No.

450,
057498

578,
057501

794,
057499

972,
057502

kW

15,08 31,40

22,76 46,73

32,22 66,25

40,95 84,91

Air delivery

m/ h

1.100

1.250

1.950

2.550

Gas consumption

kg/h

1,03 2,13

1,54 3,15

2,19 4,47

2,78 5,76

Electrical connection

V/Hz

Electrical power supply

230/50-60

kW

0,09

0,112

0,14

0,24

LPG

Piezo ignition

Connection device with hose

Length

mm

511

511

538

538

Width

mm

277

277

317

317

Height

mm

505

575

580

700

Weight

kg

10

12

14

16

Power range 15 108 kW


Model

Nominal heat input

PX45

PX65

PX85

PX105

No.

759,
057494

972,
057492

1.080,
057495

1.367,
057493

1.439,
057496

kW

15,08 31,40

22,76 46,73

32,22 66,25

40,95 84,81

48,81 108,71

Air delivery

m/ h

1.100

1.250

1.950

2.550

3.700

Gas consumption

kg/h

1,03 2,13

1,54 3,15

2,19 4,47

2,78 5,76

3,3 7,37

Electrical connection

V/Hz

Electrical power supply


Mobile warm air heaters /
Mobile heat plant

PX32

230/50

kW

0,09

0,112

0,14

0,24

0,4

LPG

Electric ignition

Connection device with hose

Length

mm

511

511

538

538

606

Width

mm

277

277

317

317

438

Height

mm

505

575

580

700

835

Weight

kg

10

12

14

16

26

Accessories

P32 P85

Room thermostat IP54


10 m cable, plug included

No.

Gas bottle extension to connect


more than one gas bottle

No.

Retrofit kit for drivability and


stackability

72

No.

PX32 PX105
140,
000729

69,
005346

69,
005346

P32 P65/PX32 PX65

P85/PX85

55,
057508

61,
057509

Gas-fired
heaters
Power range 45 111 kW
Model

Nominal heat input

PE45

PE90

PE112

No.

1.760,
058582

2.371,
058583

2.526,
058584

kW

45

88,8

111

2.500

4.700

6.650

4,08

7,84

9,94

3,13

6,1

7,79

Air delivery

m/ h

Gas consumption
natural gas

m/h

Gas consumption
LPG

kg/h

Electrical connection

V/Hz

Electrical power supply

kW

230/50
0,25

0,6

0,98

Gas valve block

Stainless steel casing

Length

mm

792

1146

1187

Width

mm

437

589

684

Height

mm

326

441

435

Weight

kg

21

46

56

dB(A)

74

77

75

Noise level

Accessories

PE 45 PE112

Room thermostat IP54


10 m cable, plug included

No.

140,
000729

Gas bottle extension to connect


more than one gas bottle

No.

69,
005346

Mobile warm air heaters /


Mobile heat plant

73

Electric heaters

Mobile warm air heaters /


Mobile heat plant

E18SH with hose


and room thermostat

E3

Delivered units may differ from the pictures.

74

E8

E12/E18

Electric heaters
Characteristics:
Temperature rise up to 60 Kelvin
Built-in room thermostat
Enamelled casing made of galvanized sheet metal
Compact and robust
Two-stage heating performance (E8 E18)
External room thermostat connection (E18H/E18SH)
Warm air hose connection (E18SH)
Special versions for pest control (E18H)

The electric heaters are ...


... universal
The electric fan heaters are perfect for use in rather small rooms and in rooms of medium
size.The smaller types are the ideal extra heaters in large rooms.
They are designed for being operated in workshops, nurseries, shops, exhibition rooms,
warehouses, site huts, or elsewhere on building sites.
There, they provide c
omfortable heat in spring and in autumn or if there is a sudden onset
of cold weather. They can be used as frost control, too.
... economical
The heat is dispensed efficiently and in a concentrated way to the ambient air by a powerful fan.
... comfortable
The electric fan heaters do not use up any oxygen. They do not give off any unpleasant
smell at all, so they can also be operated in rooms which have bad or even no means of
ventilation. They are ready for use e
verywhere, and at once. Temperature can be adjusted
and is controlled by a thermostat.
In summer, they can be used for v
entilating rooms as well.
... robust and safe

... mobile
Thanks to their small dimensions, the electric fan heaters can be taken everywhere.
You will find a place for them even in very confined space.
Model E18 now also available as version SH, S for hose connection and version H for
operation at high room temperatures for special duties such as thermal pest control.

75

Mobile warm air heaters /


Mobile heat plant

All appliances are VDE-checked and thermally protected. The enclosed heating elements
have got a stainless jacket, the boxes consist of g
alvanized steel sheet and, in addition,
they are s tove-enamelled. They are of stable construction!

Electric heaters
Power range 3 18 kW
Model

Nominal heat input


Air delivery

E3

E8

E12

E18

E18SH

No.

400,
000138

919,
000143

1.251,
000147

1.593,
000153

1.702,
053432

kW

4/8

6 / 12

12 / 18

12 / 18

185

420

735

960

960

m/h

Pressure

Pa

Ambient temperature max.

40

40

40

40

60

44

41

42

60

60

Schuko
plug

CEE
16 A

CEE
32 A

CEE
32 A

CEE
32 A

Temperature rise
Connection type
Electrical connection

V/Hz

Built-in room thermostat

100

230 / 50
+

Heating performance 2-stage

400 / 50
+

External room thermostat


Width

mm

185

285

320

320

320

Length

mm

330

530

666

666

990

Height

mm

270

395

435

435

435

Weight

kg

6,4

16,5

20,5

23,5

32,0

dB(A)

52

56

56

56

64

E18

E18SH

Noise level

Accessories

Mobile warm air heaters /


Mobile heat plant

Warm air hose 3 m 305 mm


-40C to +175C

413,
045720

Connection piece 305 mm


for hose extension

34,
002873

External room thermostat

280,
056355

Transport frame

76

248,
053481

248,
053481

Dehumidifiers

TE80 TE120

TK30 TK60

TE40

T24
Dehumidifying

Delivered units may differ from the pictures.

77

Dehumidifiers
Characteristics:
Dehumidifiers, TE units
Steel casing,
powder-coated
Hours counter
Hot gas defrosting
Drip pan
Hygrostat connection

Dehumidifiers, TK units
Integrated hygrostat
Steel casing,
powder-coated
Hours counter
Hot gas defrosting
Drip pan
Modularly extendable
Stackable

Kroll offers a large range of dehumidifiers.


The right model for each request.
The professional units TE40 TE120 and TK30/TK60 are used to accelerate drying process
with new buildings, at renovation works and to fix water damages.
Mobile:
The units are easy to install, immediately ready for use and of silent operation.
Automatic hot gas d
efrosting:
Ensures trouble-free operation also when the unit is running permanently.
This leads to an elevated degree of efficiency and very short operation breaks.
Wide range of operation:
From 0 to 35C, at 30 to 95% relative air h
umidity (see technical data table).
TE models with additional heating
The additional electric heating (2 kW) raises the room temperature at cold weather
and thus improves the dehumidifying performance.
Long durability:
The robust long-time filter which is easy to clean increases the units lifespan.
Further advantages:
Overflow switch with magnetic contact
CFC-free refrigerant: to protect the environment and the ozone layer
LED display informs about the current operating status.
Electronic and safety control for fully automatic operation.
Important when renting the units:
Hours counter
Stackable (only TK models)

Dehumidifying

Useful accessories:
Hygrostat (integrated with TK models)
Condensate pump
Overflow protection for external collecting pan

78

Dehumidifiers
Power range 30 60 l/24h
Model

No.

T24

TK30

TK60

553,
030060

914,
050653

1.706,
050654

Maximum dehumidifying capacity*

l/24h

30

30

60

Air delivery

m/ h

230

580

1.000

Operating range humidity

% RF

30 80

30 90

30 90

5 35

5 32

Operating range temperature

Refrigerant
Electrical connection
Electrical power consumption

R410A

5 32
R407C

V/Hz

230 / 50

kW

0,52

0,65

1, 07

Width

mm

340

480

530

Length

mm

250

570

560

Height

mm

545

980

1000

Weight

kg

13,2

34

40

Drip pan

10

10

Hours counter

Condensate pump connection

Stackable

Inbuilt power socket

Hot gas defrosting


Noise level

dB(A)

49

52

56

* 30C/90% relative air humidity.

Power range 40 120 l/24h


Model
With electric additional heating 2,0 kW

No.

TE40

TE80

TE100

TE120

1.913,
000114

2.781,
038856

3.049,
039239

3.653,
039368

Maximum dehumidifying capacity*

l/24h

40

80

100

120

Air delivery

m/ h

500

1.100

1.100

1.500

Operating range humidity

% RF

30 95

0 35

Operating range temperature


Refrigerant
Electrical connection
Electrical power consumption
Width

R407C
V/Hz

230 / 50

kW

0,78/2,78

1,15/3,15

1,28/3,28

1,40/3,40

mm

540

620

620

620

Length

mm

900

615

615

580

Height

mm

660

860

860

1070

Weight

kg

37

52

53

58

14
+

Drip pan
Hours counter

Condensate pump connection

Stackable

50

57

57

58

Noise level

dB(A)

Dehumidifying

Hot gas defrosting


Additional heating (2 kW)

* 30C/90% relative air humidity.

79

Dehumidifiers
Accessories

TK30

TK60

TE40

TE80

TE100

TE120

Hygrostat

No.

integrated

integrated

112,
046075

112,
046075

112,
046075

112,
046075

Condensate pump

No.

269,
049946

269,
049946

269,
021779

269,
021779

269,
021779

269,
021779

4,3

4,3

5,4

5,4

5,4

5,4

95,
021780

95,
021780

95,
021780

95,
021780

Max. delivery height

Dehumidifying

Overflow protection for


external collecting pan

80

No.

Notes

81

Conditions of Sales
and Delivery
(Version 03/15)
In commercial business transactions
1 General Conditions
1. Our sales and delivery conditions are exclusively applicable. Statements of the Buyer contradicting to or deviating from our general business conditions will not be recognized, although they are not explicitly contradicted
and/ or delivery has been affected without any reservation.
2. These sales and delivery conditions are applicable for all current and future business relations. Former, eventually otherwise expressed sales and delivery conditions lose their validity.
2 Conclusion of the contract
1. Our offers are subject to change.
2. Technical and constructive changes, like change in form, color and / or weight are subject to reasonable
changes.
3. Orders, amendments and changes to an order, shall be recognized only when they are confirmed by us in a
written form, or the goods from the order are already delivered.
4. Costs estimations, drawings and other similar documents should be treated as private and intellectual property
of our company and we reserve the rights for them.
3 Terms of delivery
1. Agreed delivery periods begin with the conclusion of the contract, however, not before the receipt of all
documents to be given from the purchaser, including complete technical specification, authorizations, approvals or provisions, which are necessary for the execution of the contract, and not before the agreed payment
is received.
2. The Seller is authorized to undertake a partial delivery, in case they are inevitable and reasonable.
3. Events of acts of nature beyond controls, as well as other unforeseen circumstances, especially malfunctions in
provision, production or delivery, strike, lockout or similar, release us for the duration of the perturbation, as well
as for a reasonable start-up period, also during an already given delayed delivery period, from our delivery
obligation, as far as the perturbation has not been caused consciously or grossly negligently by us, our legal representatives, auxiliary persons or assistants. If delivery becomes, for the above mentioned reasons, impossible
or economically unreasonable, we are released from our contractual obligations. Claims for damages from
the purchaser are excluded.
4. Our delivery obligation stays at rest, as long as there are not only inessential purchasers depts. in arrears.
4 Prices and payment conditions
1. The prices confirmed by us are applicable ex works, packing excluded, plus the current obligatory value
added tax.
2. For orders whose net value of goods is less than EUR 50, we charge a small quantity surcharge of EUR 25,.
3. Expenditures that arise from changes in the way or the amount of the delivery and on request of the buyer after
our order confirmation, and/ or arising from the fulfillment of afterwards occurred, or unforeseeable authority
instructions, will be also charged in addition to the quoted purchasing price.
4. In case of decisive change of price factors for working material, vendor parts, salaries, social charges, energy
costs, turnover and commercial taxes or customs duties after the conclusion of the contract, we reserve the right
to increase the prices stated in the order confirmation, accordingly for those goods, that are to be delivered
after more than six weeks after conclusion of the contract. In case of a price increase of more than 5% on the
prices stated in the order confirmation, the purchaser has the right to resign from the contract within one month
after being informed of the change in price.
5. Assembly costs will be separately charged.
6. Discounts from price are to be stated in written form.
7. The Buyer has the right for charging only when his / her claim is legally stated, unquestionable or acknowledged by us.
8. Unless otherwise specified, the purchasing price is to be paid without deduction within 30 days after invoice
date. The Buyer has the right of retention only as far as his/ her counterclaim is based on the same contractual
relation.
9. If we become aware of any circumstances, which justify legitimate doubts concerning the Buyers creditworthiness, and if the Buyer is, in spite of respective demand, not ready to pay in advance or to provide appropriate security, we reserve the right to resign from the contract.
5 Transfer of perils
1. The delivery of goods is generally executed ex works.
2. Risk of coincidental loss or coincidental deterioration of goods is passed to the Buyer when the Goods are
placed at the disposal of the Buyer at the Sellers premises, or, in case of consignment purchase, in the moment
of transfer of the goods to the forwarding agent. When the Buyer is unable to receive the goods, the risk of
coincidental loss and of coincidental deterioration of the goods is passed from the Seller to the Buyer from the
day on, when the Buyer is advised of the goods readiness to be dispatched. Eventually occurring storage costs
are for the account of the Buyer.

82

Conditions of Sales
and Delivery
6 Reservation of property rights
1. We reserve the property right for our goods, until entire payment is received, also for all outstanding claims
existing in the complete business relation.
2. In case the Buyer does not abide the contract, especially concerning the payment conditions, we have the
right to cancel the contract and to collect back our goods. After taking back the goods, we have the right to
use them. The revenue coming out of the exploitation of the goods is credited on the Buyers payables appropriate costs of exploitation deducted. In case the withdrawal cannot be realized we are entitled to claim for
damages.
3. The Buyer has the right to resell the goods in accordance with his / her adequate and orderly accounting
business. The buyer transfers, already now, all claims against his buyers of the resold goods, to us. We herewith
accept the transfer. The Buyer remains authorized to collect claims transferred to us. This authorization expires
immediately when the Buyer ceases his payments.
4. In case of garnishment, other interventions of other persons or eventual damages or destruction of the goods,
the Buyer has to inform us immediately. Also a change of property of the purchased subject, as well as a
change of registered office has to be indicated without delay.
7 Claims for defects
1. The Buyer has the right to claim defects only after his duly fulfilled obligations of inspection and reprimand
according to 377 HGB.
2. In case there is evidence of defect taken by us, we will eliminate it at our option and for our account, or we
will deliver goods without defects (supplementary performance). The purchaser has the obligation to allow
examination of the goods if demanded also by third party.
3. As character of the object of purchase, only our product description is valid. Parallel public exclamation, praise
or advertising does not represent any contractual indication of the character of the goods.
4. We take responsibility according to legal law, as far as the purchaser is claiming compensation, which result
of intention or gross negligence. As long our behavior cannot be proved as an intentional or grossly negligent
breach of duty, the responsibility of compensation is limited to the damage, arising typically in the respective
case. This is not valid for responsibility of life, body or health, neither for the obligatory responsibility according
to the law of product liability.
5. The period for claiming defected goods by the purchaser is one year from the date of delivery of the goods.
6. The purchaser is not given any guaranties in the sense of Law by us. Guarantees of producer are not concerned
herewith.
8 Responsibility
1. Concerning other claims for damages we are responsible at best, in case of lightly negligent breach of duty,
only for that kind of damage, that is typically arising for this kind of the object of purchase. This is valuable also
for lightly negligent breaches of duty by our legal representatives or assistants.
2. Our responsibility for lightly negligent breaches of unessential duties is excluded.
3. Responsibility of guilty damage of life, body or health remains untouched. The same applies to the obligatory
responsibility according the law of product liability.
9 Place of fulfillment
The place of fulfillment for delivery is respectively the place from where the goods are sent, for payments and other
liabilities reporting to the contract it is the address of the our registered office.
10 Final Clauses
1. The law of the Federal Republic of Germany is valid. The clauses of UN Convention on Contracts for the International Sale of Goods are not applicable.
2. As an exclusive jurisdiction for all disputes out of this contract the competence of either the Regional or the
County court is agreed, dependent of the value of the object.
3. Purchasers date necessary for the execution of the order, are safe and processed for own purpose. Notification according 33 BDSG resulted with this.
4. Should single terms of the contract, including these conditions of sale and delivery, are or become partially
or completely void, the validity of the other terms remain thereof untouched. The completely or partially void
term, shall be replaced by a term, whose economic success is as close as possible to that of the void term.

Kroll Energy GmbH


Highly modern production lines and a constant, uncompromising quality management ensure that Kroll products
are of impeccable workmanship and long durability.

83

References

Site:
Valle Nevado / Santiago de Chile

Site:
Evento Hipodromo / Santiago de Chile

Site:
Valle Nevado / Santiago de Chile

Site:
Centro de Eventos / Santiago de Chile

Site:
Venta Equipos Ski en Mall / Santiago de Chile

Site:
Davos / Switzerland

Site:
Restaurant Waldegg / St. Gallen

Site:
Film festival Lima / Peru

84

References

Site:
AGRIA works / Mckmhl

Site:
Hotel Martigny / Valais, Switzerland

Site:
Mercedes car dealership / Singen

Site:
Hotel San Gian / St. Moritz

Site:
Friedensburg Rathen / Elbe Sandstone Mountains

Site:
VOLVO car dealership / Bettembourg

Site: Residential buildings complex with


144 flats / Wildberg, Black Forest

85

References

Site:
Mine and tent heating in the Chilean Andes,
3500 m above sea level.

Site:
Minera Quadra Antofagasta / Chile

Site:
Hospital de Campana Armade / Chile

Site:
Flood School in Farnham / England

Site:
koda showroom / Romania

86

Kroll Energy GmbH


Pfarrgartenstrae 46 71737 Kirchberg / Murr, Germany
phone +49 7144 830 -200 fax +49 7144 830 -201
vertrieb@kroll.de www.kroll.de
Service hotline +49 7144 830-222
Price List 2015
Technical data subject to change without notice.

More Information on the Kroll product range on: www.kroll.de

You might also like